Choice & Convenience Laboratory Glassware

100
Choice & Convenience Laboratory Glassware Containerware General Glassware Volumetric Glassware Interchangeable Test, Culture & Specialty Tubes

Transcript of Choice & Convenience Laboratory Glassware

* denotes products not stocked

Choice & ConvenienceLaboratory GlasswareContainerware • General Glassware Volumetric Glassware • Interchangeable

Test, Culture & Specialty Tubes

Glassware is one of the staple products used in every laboratory and in this new

glassware catalogue, Thermo Fisher Scientific offers you a range and choice of

products which will suit every budget.

The catalogue showcases a host of leading glassware brands, offering you both

choice and convenience when selecting glassware for your laboratory. Quality

and precision are the hallmarks of the glassware range available from Thermo

Fisher, so irrespective of the brand you select you can be confident you will

receive quality products.

Readily available stock is an important factor when ordering glassware items. To

assist you in this process, the catalogue denotes those items which are generally

available from stock.

The availability of appropriate certification is increasingly becoming an important

factor, particularly when buying volumetric glassware. Recognising this need, the

catalogue features products which again provide you with several options relating

to glassware calibration and certification.

While the catalogue is intended to showcase the main glassware products which

are readily available, it is not all encompassing. If you are unable to locate an item

you require, please contact your local Account Manager or Customer Service

Representative and we will endeavour to source the product on your behalf.

Finally, we trust you will find the catalogue beneficial and would encourage you

to take advantage of the extensive knowledge and expertise Thermo Fisher have

available to assist you in sourcing all your glassware needs.

A World of Choice for Glassware

Sectio

n >>

S

ub

-Sectio

n

Containerware Volumetric Glassware

Test, Culture & Specialty Tubes

Related ProductsInterchangeable Glassware

General Glassware

pg. 05 pg. 21 pg 33

pg. 67pg. 57 pg. 83

A World of Choice for Glassware

Please also see our Technical Information section on page 87.

At Thermo Fisher Scientific, we continuously strive to bring our

customers the best quality and innovative products and solutions.

We achieve this through forming partnerships with supplier

partners who specialise in market leading brands. Our success

is attributed to the significant support from our suppliers and it is

through these relationships that we relentlessly strive to extract

value for our customers.

Our Partnership Suppliers

containerware

Beakers 06

Heavy Duty Beakers 08

Philips Beakers 09

Media Bottles 10

Boston Bottles 12

Erlenmeyer Flasks 14

Starter Packs 17

Plastic Coated Glassware 18

6

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Containerware

BeakersSynonymous with quality and affordability, the range of LabServ glassware offers durability at competitive prices. Buy quality, reusable glass beakers at disposable prices. Use LabServ borosilicate glass beakers for routine measurement, mixing and gentle heating. Chemically resistant to most solvents, acids and bases.

Item Code CapacityGraduations Range (mL)

Graduations Interval (mL)

OD x Height Pack Size Unit

LBS20201-50 50mL 10-40 5 42x60mm Each Pack of 12/Case of 192

LBS20201-100 100mL 20-80 10 50x70mm Each Pack of 12/Case of 192

LBS20201-150 150mL 20-140 10 60x80mm Each Pack of 12/Case of 192

LBS20201-200 * 200mL 25-175 10 66x90mm Each Pack of 12/Case of 144

LBS20201-250 250mL 25-200 25 70x95mm Each Pack of 12/Case of 144

LBS20201-300 * 300mL 25-250 25 74x105mm Each Pack of 12/Case of 96

LBS20201-400 400mL 50-350 25 80x110mm Each Pack of 12/Case of 72

LBS20201-500 500mL 50-400 25 85x120mm Each Pack of 6/Case of 72

LBS20201-600 600mL 100-500 50 90x125mm Each Pack of 6/Case of 48

LBS20201-800 800mL 100-750 50 100x135mm Each Pack of 6/Case of 36

LBS20201-1L 1,000mL 100-900 50 105x145mm Each Pack of 6/Case of 24

LBS20201-2L 2,000mL 200-1800 100 130x185mm Each Pack of 4/Case of 16

LBS20201-3L 3,000mL 300-2800 100 150x210mm Each Case of 8

LBS20201-4L * 4,000mL 500-3500 500 161x253mm Each Each

LBS20201-5L 5,000mL 500-4500 500 170x270mm Each Case of 6

LabServ Low Form Beaker, Griffin, Borosilicate glass, Double Scale

Conta

inerw

are

* denotes products not stocked

Containerw

are >>

B

eake

rs

7

Item Code CapacityGraduations Range (mL)

Graduations Interval (mL)

OD x Height Pack Size Unit

LBS20202-50 50mL 10-40 10 38x70mm Each Pack of 24/Case of 192

LBS20202-100 100mL 20-80 10 48x80mm Each Pack of 24/Case of 192

LBS20202-150 150mL 20-140 20 54x95mm Each Pack of 12/Case of 192

LBS20202-250 250mL 25-200 25 60x120mm Each Pack of 12/Case of 72

LBS20202-300 * 300mL 50-250 25 64x125mm Each Case of 72

LBS20202-400 400mL 50-350 25 70x130mm Each Pack of 12/Case of 72

LBS20202-500 * 500mL 100-400 50 75x140mm Each Case of 48

LBS20202-600 600mL 100-500 50 80x150mm Each Pack of 6/Case of 48

LBS20202-800 800mL 100-750 50 90x175mm Each Case of 48

LBS20202-1L 1,000mL 100-900 50 95x180mm Each Pack of 6/Case of 36

LabServ Tall Form Beaker, Berzelius, Borosilicate glass, Double Scale

Kimble Brand KIMAX beakers provide strength and durability from top to bottom. Uniform sidewall and bottom thickness, especially in the critical radius point of the heel area, provides excellent mechanical and thermal shock resistance. The chemical and physical properties of KG-33 glass ensure high resistance to heat shock and chemical attack.

Item Code CapacityGraduations Range (mL)

Graduations Interval (mL)

OD x Height Pack Size Unit

KIM14000-10 10mL - - 25x34mm Each Each/Pack of 12/Case of 48

KIM14000-20 * 20mL 5-15 5 32x41mm Each Case of 48

KIM14000-30 * 30mL 5-25 10 35x53mm Each Case of 48

KIM14000-50 * 50mL 10-40 10 42x53mm Each Pack of 12/Case of 48

KIM14000-100 100mL 20-80 10 50x70mm Each Each/Pack of 12/Case of 48

KIM14000-150 150mL 20-140 20 57x81mm Each Each/Pack of 12/Case of 48

KIM14000-250 250mL 25-200 25 68x88mm Each Each/Pack of 12/Case of 48

KIM14000-400 400mL 50-325 25 77x106mm Each Each/Pack of 12/Case of 48

KIM14000-600 600mL 50-500 50 88x122mm Each Each/Case of 6

KIM14000-800 * 800mL 50-750 50 99x136mm Each Pack of 6/Case of 24

KIM14000-1000 1,000mL 100-1000 50 107x145mm Each Each/Pack of 6/Case of 24

KIM14000-1500 * 1,500mL 200-1400 100 120x165mm Each Pack of 4/Case of 16

KIM14000-2000 2,000mL 200-2000 100 130x190mm Each Each/Pack of 4/Case of 8

KIM14000-4000 * 4,000mL 500-3500 250 161x250mm Each Case of 6

Kimble Low Form Beakers

8

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Containerware

Conta

inerw

are

Heavy Duty BeakersKIMAX beakers with thick uniform walls throughout and extra wall thickness built into the evenly tooled top rim. Spout is designed for optimum performance. Heavy construction is intended to prolong life with harder than normal usage (i.e. mechanical shock). Not recommended for use on hot plates where significant thermal gradients exist due to lack of agitation of contents or absence of a temperature control. All sizes have a durable matte finish marking area and a white graduated scale. Designed from ASTM Specification E960, Type II requirements.

Item Code CapacityGraduations Range (mL)

Graduations Interval (mL)

OD x Height Pack Size Unit

KIM14005-250 250mL 25-200 25 67x92mm Each Case of 48

KIM14005-400 400mL 25-325 25 77x114mm Each Case of 48

KIM14005-600 600mL 50-500 50 87x122mm Each Case of 36

KIM14005-1000 1,000mL 100-1000 50 107x152mm Each Case of 24

KIM14005-2000 2,000mL 200-1800 200 130x190mm Each Case of 8

KIM14005-4000 4,000mL 500-3500 500 161x252mm Each Case of 4

Kimble KIMAX Beaker, Spouted, Heavy Duty, Low Form, Double Capacity White Colour Scale

* denotes products not stocked

Containerw

are >>

H

eavy D

uty &

Philip

s Beake

rs

9

Philips Beakers

Item Code Capacity Diameter Height Pack Size Unit

SCH2114129 * 150mL 59mm 87mm 10 pcs Each

SCH2114136 * 250mL 68mm 105mm 10 pcs Each

SCH2114144 * 500mL 86mm 142mm 10 pcs Each

Schott Duran Philips Beakers, With Spout

10

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Containerware

Conta

inerw

are

Media Bottles• Enhanced graduations

• Permanent white enamel marking spot

• GL 45 screw thread

• Clear (natural), drip-free, replaceable polypropylene pour ring

• Linerless

• Autoclavable (to 140°C)

• Polypropylene cap

Item Code CapacityGraduations Range (mL)

Graduations Interval (mL)

Approx. OD x Height (Unassembled)

Pack Size Unit

FSBFB33144 100mL 20-80 10 56x100mm Each Case of 10

FSBFB33145 250mL 50-200 25 70x138mm Each Case of 10

FSBFB33146 500mL 100-400 50 86x176mm Each Case of 10

FSBFB33147 1,000mL 100-900 50 101x225mm Each Case of 10

FSBFB33148 2,000mL 400-1800 100 136x262mm Each Each

FSBFB33180 5,000mL 1000-4000 250 186x355mm Each Each

FSBFB33181 10,000mL 2000-8000 500 234x435mm Each Each

Item Code Description GL Thread Colour Pack Size Unit

FSBGLBBC Screw cap PP 45 Blue Each Case of 10

FSBGLBBR Pouring ring PP 45 Clear Each Case of 10

FSBGLBRC Screw cap PBTP with liner 45 Red Each Case of 10

Fisherbrand Graduated Laboratory Bottles, with Polypropylene Screw Cap and Pouring Ring

Fisherbrand Screw Caps and Pouring Rings

* denotes products not stocked

Containerw

are >>

M

ed

ia Bottle

s

11

Schott Duran Graduated Laboratory Bottles, with Polypropylene Screw Cap and Pouring Ring

Schott Duran Screw Caps and Pouring Rings

Item Code Capacity GL Thread Width (mm) Height (mm) Pack Size Unit

SCH21801175 50mL 32 46 87 Each Case of 10

SCH21801245 100mL 45 56 100 Each Case of 10

SCH21801365 250mL 45 70 138 Each Case of 10

SCH21801545 1,000mL 45 101 225 Each Case of 10

SCH21801635 2,000mL 45 136 260 Each Case of 10

Item Code Description GL Thread Colour Pack Size Unit

SCH2923928 Screw cap PP 45 Blue Each Case of 10

SCH2924228 Pouring ring PP 45 Blue Each Case of 10

The RAY-SORB® process provides a shield to protect light sensitive products. Less than 1% transmission below 400 nm and reduced (5%) from 400-600 nm as compared to untreated, clear, borosilicate glass. Bottles are provided with enhanced graduation scale; cap and drip-free pour ring included.

Item Code CapacityGraduations Range (mL)

Graduations Interval (mL)

OD x Height* Pack Size Unit

KIM14399-500 * 500mL 100-400 50 86x176mm Each Each

KIM14399-1000 * 1,000mL 100-900 50 101x225mm Each Each

KIM14399-2000 * 2,000mL 400-1800 100 136x262mm Each Each

KIM14399-5000 * 5,000mL 1000-4500 250 186x355mm Each Each

KIM14399-10000 * 10,000mL 2000-9000 500 234x435mm Each Each

* Approximate OD x Height Unassembled

Kimble Graduated Laboratory Bottles, RAY-SORB, with Polypropylene Scew Cap

12

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Containerware

Conta

inerw

are

Boston Bottles

Item Code Type Capacity Neck Finish Height Diameter Pack Size Unit

COSH0529 * Clear bottle 50mL 24mm 86mm 38mm 220pcs Each

COSH0936 * Clear bottle 100mL 24mm 107mm 47mm 56pcs Each

COSH1631 * Clear bottle 200mL 24mm 136mm 59mm 39pcs Each

COSH721 * Amber bottle 100mL 24mm 109.4mm 45.9mm 122pcs Each

COSH720 * Amber bottle 200mL 24mm 135.9mm 57mm 82pcs Each

COSH725 Amber bottle 500mL 28mm 183.7mm 75.4mm 25pcs Each

COSH4701 Amber bottle 1,000mL 33mm 206mm 96mm 12pcs Each

COS2450 * White wadded cap 24mm Each Each

COS2855 White wadded cap 28mm Each Each

COS3331 * White wadded cap 33mm Each Each

Available in Australia Only

Cospak Bottles, Clear and Amber, Round, Caps Sold Separately

* denotes products not stocked

Containerw

are >>

B

osto

n B

ottle

s

13

• Boston round amber Type III glass bottle

• Caps for 125mL and 250mL sizes are ultrasonically bonded with a .125” Teflon®-lined silicone liner

• Caps for 500mL and 1000mL sizes are equipped with a friction-fit Teflon® liner which is easily replaced if necessary

• Polypropylene closure. Excellent for water sampling. Recommended for UV light sensitive samples

• I-CHEM Certified® 200 and 300 Series bottles are guaranteed to meet the EPA’s Performance Based Specifications for Metals (Group 1) and Semi-Volatiles/Pesticides/PCBs (Group 2) analysis

Item Code Type Capacity Group Closure Pack Size Unit

NALICHEM249-0250 * Round amber bottle 250mL 1&2 24-414 Each Case of 12

NALICHEM249-0500 * Round amber bottle 500mL 1&2 28-400 Each Case of 12

NALICHEM249-1000 Round amber bottle 1,000mL 1&2 33-430 Each Case of 12

NALICHEM241-0250 * Tall wide mouth amber bottle 250mL 1&2 45-400 Each Case of 12

Kimble Chase Boston Round Bottles

14

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Containerware

Conta

inerw

are

Erlenmeyer FlasksSynonymous with quality and affordability, the range of LabServ glassware offers durability at competitive prices. Buy quality, reusable glass flasks at disposable prices. Use LabServ borosilicate glass flasks for routine measurement, mixing and gentle heating. Chemically resistant to most solvents, acids and bases.

Item Code Capacity Neck OD Flask OD Height Pack Size Unit

LBS20401-02-50 * 50mL 26mm 54mm 80mm Each Case of 192

LBS20401-02-100 100mL 32mm 66mm 106mm Each Case of 192

LBS20401-02-150 * 150mL 32mm 75mm 124mm Each Case of 144

LBS20401-02-250 250mL 34mm 85mm 140mm Each Case of 72

LBS20401-02-300 * 300mL 34mm 90mm 162mm Each Case of 48

LBS20401-02-500 500mL 38mm 103mm 184mm Each Case of 48

LBS20401-02-1L * 1,000mL 45mm 131mm 214mm Each Case of 24

LBS20401-02-2L 2,000mL 50mm 166mm 280mm Each Case of 12

LBS20401-02-3L 3,000mL 50mm 187mm 310mm Each Case of 6

LBS20401-02-5L 5,000mL 50mm 220mm 365mm Each Case of 6

LabServ Erlenmeyer Flasks, Narrow Neck, Graduated

Item Code Capacity Neck OD Flask OD Height Pack Size Unit

LBS20401-04-250 250mL 34mm 85mm 140mm Each Case of 72

LBS20401-04-500 * 500mL 34mm 105mm 175mm Each Case of 48

LBS20401-04-1L * 1,000mL 42mm 131mm 220mm Each Case of 24

LabServ Erlenmeyer Flasks, Wide Neck, Graduated

* denotes products not stocked

Containerw

are >>

E

rlenm

eyer F

lasks

15

Item Code Capacity Flask OD Pack Size Unit

GLS075.202.01 * 50mL 51mm 10pcs Each

GLS075.202.02 * 100mL 64mm 10pcs Each

GLS075.202.03 * 150mL 74mm 10pcs Each

GLS075.202.04 * 250mL 85mm 10pcs Each

GLS075.202.05 * 500mL 105mm 10pcs Each

GLS075.202.06 * 1,000mL 131mm 10pcs Each

Glassco Erlenmeyer Flasks, with PTFE Lined Screw Cap, Graduated

Kimble brand KIMAX erlenmeyer flasks, reinforced beaded top with capacity scale. All flasks have durable white ceramic enamel scales to indicate approximate volumes at various levels, useful in measuring and mixing solutions where a high degree of accuracy is unnecessary. Designed from ASTM Specification E1404, Type I, Class 1 requirements.

Item Code CapacityGraduations Range (mL)

Graduations Interval (mL)

Widest Diameter (mm)

Height (mm) Pack Size Unit

KIM26500-25 * 25mL 10-25 5 39 65 Each Case of 48

KIM26500-125 * 125mL 50-125 25 66 108 Each Case of 48

KIM26500-250 250mL 50-225 25 82 130 Each Case of 48

KIM26500-500 * 500mL 100-500 50 102 174 Each Case of 36

KIM26500-1000 * 1,000mL 250-1000 50 128 213 Each Case of 24

KIM26500-2000 * 2,000mL 600-2000 100 161 275 Each Case of 8

Kimble Erlenmeyer Flasks, Narrow Neck

16

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Containerware

Conta

inerw

are

Item Code CapacityGraduations Range (mL)

Graduations Interval (mL)

Widest Diameter (mm)

Height (mm) Pack Size Unit

KIM26650-125 125mL 50-125 25 66 108 Each Case of 48

KIM26650-250 250mL 50-22 25 77 130 Each Case of 48

KIM26650-500 * 500mL 100-500 50 97 172 Each Case of 36

KIM26650-1000 * 1,000mL 250-1000 50 122 216 Each Case of 24

KIM26650-2000 * 2,000mL 600-2000 200 161 265 Each Case of 8

Item Code CapacityGraduations Interval

SubdivisionWidest Diameter (mm)

Height mm Pack Size Unit

KIM27060-500 * 500mL 150-500 50 104 190 Each Case of 18

KIM27060-1000 1,000mL 300-1000 50 135 238 Each Case of 12

KIM27060-2000 * 2,000mL 600-2000 100 168 300 Each Each

Kimble Erlenmeyer Flasks, Wide Neck

Kimble Erlenmeyer Filtering Flasks, with Capacity Scale and Side Tubulation

* denotes products not stocked

Containerw

are >>

E

rlenm

eye

r Flasks &

Starte

r Pac

ks

17

Starter PacksSave money and space by getting a variety of sizes without having to order case quantities of each size. They provide precisely what you need, when you need it, without the extras that could slow you down.

Item Code Type Sizes (mL) Pack Size Unit

KIM14080-01 * Beakers 50, 100, 250, 600, 1000 5pcs Each

KIM14085-01 * Heavy duty beakers 250, 400, 600, 1000 4pcs Each

KIM26520-1 * Erlenmeyer flasks 10, 25, 50, 100, 250 5pcs Each

KIM20024-01 * Cylinders 20, 125, 250, 500, 1000 5pcs Each

Kimble Lab Starter Packs, One of Each Size Included

18

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Containerware

Conta

inerw

are

Plastic Coated GlasswareKimCote® Plastic-Coated Glassware for an Added Measure of Safety.

Plastic coating on glassware Prevents & contains spills in broken glassware Ultra-clear coating Improved sample viewing Non-slip coating surface Easier handling in the lab Steam autoclavable Easy to clean and sterilise Chemically resistant Use with hazardous chemicals Odour free coating No noxious fumes present

KimCote® protective glassware coating goes beyond traditional coatings. Should a break occur, KimCote® will reduce the hazards of shattered glass and leakage of toxic or corrosive chemicals. It is ultra-clear, extremely durable, autoclavable and resistant to many common laboratory chemicals. KimCote®’s unique texture also provides a non-slip handling surface, wet or dry.

Kimble Plastic Coated Media Bottles

Item Code CapacityGraduations Range (mL)

Intervals (mL) Approx. OD Approx. Height Pack Size Unit

KIMKC14395-100 * 100mL 20-80 10 56mm 100mm 4pcs Each

KIMKC14395-250 * 250mL 50-200 25 70mm 138mm 4pcs Each

KIMKC14395-500 * 500mL 100-400 50 86mm 176mm 4pcs Each

KIMKC14395-1000 * 1,000mL 100-900 50 101mm 225mm 4pcs Each

KIMKC14395-2000 * 2,000mL 400-1800 100 136mm 262mm 4pcs Each

KIMKC14395-5000 * 5,000mL 1000-4000 250 186mm 355mm Each Each

KIMKC14395-10000 * 10,000mL 2000-8000 500 234mm 435mm Each Each

* denotes products not stocked

Containerw

are >>

P

lastic C

oate

d G

lassware

19

Kimble Plastic Coated Cylinders, Graduated, with Bumper

Item Code CapacityGraduations Range (mL)

Subdivisions (mL)

±Tol (mL) Approx. Height Pack Size Unit

KIMKC20028W-100 * 100mL 2-100 1 0.4 255mm Each Each

KIMKC20028W-250 * 250mL 10-250 2 0.8 330mm Each Each

KIMKC20028W-500 * 500mL 25-500 5 1.3 375mm Each Each

KIMKC20028W-1000 * 1,000mL 50-1000 10 2.5 460mm Each Each

KIMKC20028W-2000 * 2,000mL 100-2000 20 6 520mm Each Each

Kimble Plastic Coated Erlenmeyer Flasks, with Screw Cap, Wide Mouth

Item Code CapacityApprox. Widest Diameter

Approx. Height with Cap

GPI Thread Finish Pack Size Unit

KIMKC26720-250 * 250mL 81mm 130mm GL45 6pcs Each

KIMKC26720-500 * 500mL 102mm 165mm GL45 6pcs Each

KIMKC26720-1000 * 1,000mL 128mm 205mm GL45 4pcs Each

KIMKC26720-2000 * 2,000mL 161mm 265mm GL45 2pcs Each

* denotes products not stocked

Conta

inerw

are

20

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Kimble Plastic Coated Filter Flasks, Heavy-wall, 6mm Side Arm

Item Code Capacity Stopper Size Pack Size Unit

KON953760-0122 * 125mL 5 Each Each

KON953760-1002 * 1,000mL 8 Each Each

KON953760-2002 * 2,000mL 8 Each Each

KON953760-4002 * 4,000mL 8 Each Each

Containerware

Kimble Plastic Coated Volumetric Flasks, with Glass Stopper

Item Code Capacity ±Tol (mL) Stopper SizeApprox. Height with Stopper

Pack Size Unit

KIMKC28014-100 * 100mL 0.08 13 180mm 12pcs Each

KIMKC28014-250 * 250mL 0.12 16 250mm 12pcs Each

KIMKC28014-500 * 500mL 0.2 19 287mm 12pcs Each

KIMKC28014-1000 * 1,000mL 0.3 22 338mm 4pcs Each

KIMKC28014-2000 * 2,000mL 0.5 27 400mm 2pcs Each

* denotes products not stocked

volumetric glassware

Volumetric Flasks 22

Measuring Cylinders 25

Mixing Cylinders 27

Burettes 28

Automatic Burettes 29

Pipettes 30

* denotes products not stocked

Volu

metric

Gla

ssw

are

22

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Volumetric Glassware

Volumetric FlasksSynonymous with quality and affordability, the range of LabServ glassware offers durability at competitive prices. Buy quality, reusable glass flasks at disposable prices. Use LabServ borosilicate glass flasks for routine measurement, mixing and gentle heating. Chemically resistant to most solvents, acids and bases.

Item Code CapacityAccuracy Limits ±mL

Stopper Size OD x Height Pack Size Unit

LBS40620-25 25mL 0.03 10/13 37x110mm Each Case 120

LBS40620-50 50mL 0.05 10/13 49x140mm Each Case of 50

LBS40620-100 100mL 0.1 12.5/14 60x170mm Each Case of 50

LBS40620-250 250mL 0.15 14.5/15 80x220mm Each Case of 36

LBS40620-500 500mL 0.25 18.8/17 100x265mm Each Case of 24

LBS40620-1000 1,000mL 0.4 18.8/17 127x315mm Each Case of 15

LBS40620-2000 2,000mL 0.6 24/20 160x375mm Each Case of 12

LBS40620-5000 5,000mL 1.2 34.5/35 221x470mm Each Case of 6

LabServ Volumetric Flasks, Polyethylene Stopper, Class A

Sectio

n >>

S

ub

-Sectio

n

23

General G

lassware

>>

Volu

metric

Flasks

23

Glassco volumetric flasks are made from ASTM E-438 Type 1 Class A heat resistant BORO 3.3 glass that meets ISO 1042 standards. The calibration is done on automatic computer controlled machines and the flasks are calibrated to contain according to the ISO tolerance standards. These are supplied with polypropylene stoppers in both amber and clear glass. All Class A flasks are printed in blue colour. The meniscus mark is diamond ground for longer persistence and better accuracy.

Glassco Volumetric Flasks, Polypropylene Stopper, Class A, as per DIN ISO 1042 Standards, Conformity Batch Certified

Item Code Capacity Tolerance Limits ±mL Stopper Size Pack Size Unit

GLS130.202.01 5mL 0.025 10/19 Each Case of 2

GLS130.202.02 10mL 0.025 10/19 Each Case of 2

GLS130.202.02A 20mL 0.04 10/19 Each Case of 2

GLS130.202.03 25mL 0.04 10/19 Each Case of 2

GLS130.202.04 50mL 0.06 12/21 Each Case of 2

GLS130.202.05 100mL 0.1 14/23 Each Case of 2

GLS130.202.06 200mL 0.15 14/23 Each Case of 2

GLS130.202.07 250mL 0.15 14/23 Each Case of 2

GLS130.202.08 500mL 0.25 19/26 Each Case of 2

GLS130.202.09 1,000mL 0.4 24/29 Each Case of 2

GLS130.202.10 2,000mL 0.6 29/32 Each Each

* denotes products not stocked

Volu

metric

Gla

ssw

are

24

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Volumetric Glassware

Glassco Volumetric Flasks, Amber, Polypropylene Stopper, Class A, as per DIN ISO 1042 Standards, Conformity Batch Certified

Item Code Capacity Tolerance Limits ±mL Stopper Size Pack Size Unit

GLS130.202.01A * 5mL 0.025 10/19 Each Case of 2

GLS130.202.02AB * 10mL 0.025 10/19 Each Case of 2

GLS130.202.04A * 25mL 0.04 10/19 Each Case of 2

GLS130.202.05A * 50mL 0.06 12/21 Each Case of 2

GLS130.202.06A * 100mL 0.1 14/23 Each Case of 2

GLS130.202.07A * 200mL 0.15 14/23 Each Case of 2

GLS130.202.08A * 250mL 0.15 14/23 Each Case of 2

GLS130.202.09A * 500mL 0.25 19/26 Each Case of 2

GLS130.202.10A * 1,000mL 0.4 24/29 Each Case of 2

GLS130.202.11A * 2,000mL 0.6 29/32 Each Case of 2

Kimble Volumetric Flasks, RAY-SORB, with PTFE Stopper

Item Code CapacityTolerance Limits ±mL

Stopper SizeApprox. Height with Stopper

Pack Size Unit

KIM92822F-5 * 5mL 0.08 13 94mm 6pcs Each

KIM92822F-10 * 10mL 0.08 13 97mm 6pcs Each

KIM92822F-20 * 20mL 0.08 13 127mm 6pcs Each

KIM92822F-25 * 25mL 0.08 13 127mm 6pcs Each

KIM92822F-50 * 50mL 0.08 13 147mm 6pcs Each

KIM92822F-100 * 100mL 0.1 16 175mm 6pcs Each

KIM92822F-200 * 200mL 0.2 19 217mm 6pcs Each

KIM92822F-250 * 250mL 0.2 19 269mm 6pcs Each

KIM92822F-500 * 500mL 0.2 19 300mm 6pcs Each

KIM92822F-1000 * 1,000mL 0.3 22 328mm Each Each

KIM92822F-2000 * 2,000mL 0.5 27 392mm Each Each

Sectio

n >>

S

ub

-Sectio

n

25

Volu

metric

Glassw

are >>

Volu

metric

Flasks &

Measu

ring C

ylind

ers

25

Measuring CylindersGlassco measuring cylinders are made from ASTM E-438 Type 1 Class A BORO 3.3 glass that meets ISO 4788 standards. The calibration is performed on automatic computer controlled machines, and cylinders are calibrated to contain according to the ISO tolerance standards. All Class A cylinders are printed in blue colour.

Glassco Measuring Cylinders, Hexagonal Base, Class A, as per DIN EN ISO 4788 & USP Standards, with Lot Certificate

Glassco Measuring Cylinders, Hexagonal Base, Class A, as per DIN EN ISO 4788 & USP standards, with Individual Work Certificate, Serially Numbered

Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit

GLS139.202.01A 10mL 0.2 0.1 Each Case of 2

GLS139.202.02A 25mL 0.5 0.25 Each Case of 2

GLS139.202.03A 50mL 1 0.5 Each Case of 2

GLS139.202.04A 100mL 1 0.5 Each Case of 2

GLS139.202.05A 250mL 2 1 Each Case of 2

GLS139.202.06A 500mL 5 2.5 Each Case of 2

GLS139.202.07A 1,000mL 10 5 Each Each

GLS139.202.08A 2,000mL 20 10 Each Each

Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit

GLS139.223.01A * 10mL 0.2 0.1 Each Case of 2

GLS139.223.02A * 25mL 0.5 0.25 Each Case of 2

GLS139.223.03A * 50mL 1 0.5 Each Case of 2

GLS139.223.04A * 100mL 1 0.5 Each Case of 2

GLS139.223.05A * 250mL 2 1 Each Case of 2

GLS139.223.06A * 500mL 5 2.5 Each Case of 2

GLS139.223.07A * 1,000mL 10 5 Each Each

GLS139.223.08A * 2,000mL 20 10 Each Each

* denotes products not stocked26

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Volumetric Glassware

Volu

metric

Gla

ssw

are

Glassco Measuring Cylinders, Hexagonal Base, Class A, according to USP and ASTM E1272 Standards, Graduated To Deliver (TD), with Individual Work Certificate, Serially Numbered

Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit

GLS139.220.01A * 10mL 0.2 0.1 Each Case of 2

GLS139.220.02A * 25mL 0.5 0.15 Each Case of 2

GLS139.220.03A * 50mL 1 0.25 Each Case of 2

GLS139.220.04A * 100mL 1 0.5 Each Case of 2

GLS139.220.05A * 250mL 2 1 Each Case of 2

GLS139.220.06A * 500mL 5 1.5 Each Case of 2

GLS139.220.07A * 1,000mL 10 3 Each Each

GLS139.220.08A * 2,000mL 20 6 Each Each

Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit

GLS137.202.02 10mL 0.2 0.02 Each Case of 10

GLS137.202.03 25mL 0.5 0.05 Each Case of 10

GLS137.202.04 50mL 1 1 Each Case of 10

GLS137.202.05 100mL 1 1 Each Case of 10

GLS137.202.06 250mL 2 2 Each Case of 10

Glassco Measuring Cylinders, Detachable Polypropylene Base, Protection Collar, Class B, as per DIN EN ISO 4788 Standards

Sectio

n >>

S

ub

-Sectio

n

27

Volu

metric

Glassw

are >>

M

easu

ring &

Mixin

g C

ylind

ers

27

Mixing Cylinders

Glassco Mixing Cylinders, Polypropylene Stopper, Round Base, Class A, as per DIN EN ISO 4788 Standards

Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit

GLS141.202.02 * 10mL 0.2 0.1 Each Case of 2

GLS141.202.03 25mL 0.5 0.25 Each Case of 2

GLS141.202.04 50mL 1 0.5 Each Case of 2

GLS141.202.05 100mL 1 0.5 Each Case of 2

GLS141.202.06 250mL 2 1 Each Case of 2

GLS141.202.07 500mL 5 2.5 Each Case of 2

GLS141.202.08 1,000mL 10 5 Each Each

GLS141.202.09 * 2,000mL 20 10 Each Each

* denotes products not stocked

Volu

metric

Gla

ssw

are

28

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Volumetric Glassware

BurettesGlassco burettes are manufactured from ASTM E-438 Type 1 Class A BORO 3.3 heat resistant glass which meets ISO 385 and USP standards. Each and every piece is calibrated to deliver. All Class A burettes are manufactured from precision bore tubing for accuracy. The burettes are calibrated on computer controlled machines to give the most accurate results and then are rechecked at the quality control centre. Class A burettes come with either conformity batch or individual work certification. All Class A burettes are printed in blue colour and have a waiting time of 30 seconds; Class B burettes are printed in amber colour and have no waiting time.

Glassco Straight Bore Burettes, PTFE Key Stopcock, Schellbach Stripe, as per DIN ISO 385 standards, with Lot Certificate

Glassco Straight Bore Burettes, Glass Key Stopcock, Schellbach Stripe, as per DIN ISO 385 standards, with Lot Certificate

Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit

GLS114.202.04A 10mL 0.05 0.02 Each Each

GLS114.202.05A 25mL 0.1 0.03 Each Each

GLS114.202.06A 50mL 0.1 0.05 Each Each

GLS114.202.07A * 100mL Each Each

Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit

GLS110.202.01A * 10mL 0.05 0.02 Each Each

GLS110.202.02A * 25mL 0.1 0.03 Each Each

GLS110.202.03A * 50mL 0.1 0.05 Each Each

GLS110.202.04A * 100mL Each Each

Sectio

n >>

S

ub

-Sectio

n

29

Volu

metric

Glassw

are >>

B

urette

s

29

Glassco Straight Bore Burettes, PTFE Key Stopcock, Schellbach Stripe, as per DIN ISO 385 standards, with Lot Certificate

Glassco Straight Bore Burettes, Glass Key Stopcock, Schellbach Stripe, as per DIN ISO 385 standards, with Lot Certificate

Glassco Burettes, Screw Type PTFE Needle Valve Stopcock, as per DIN ISO 385 and USP standards, with Lot Certificate

Glassco Automatic Burettes, with Intermediate Stopcock, PTFE Key and Needle Valve Stopcock, Schellbach Stripe, as per DIN ISO 385 and USP Standards, Class AS, Conformity Certified

Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit

GLS113.202.01 * 10mL 0.05 0.02 Each Each

GLS113.202.02 * 25mL 0.1 0.03 Each Each

GLS113.202.03 * 50mL 0.1 0.05 Each Each

GLS113.202.04 * 100mL Each Each

Item Code Capacity Subdivision Tolerance ±mL Bottle Capacity Pack Size Unit

GLS118.240.01 * 10mL 0.05 0.02 500mL Each Each

GLS118.240.02 * 25mL 0.1 0.03 2,000mL Each Each

GLS118.240.03 * 50mL 0.1 0.05 2,000mL Each Each

Automatic BurettesGlassco burettes are manufactured from ASTM E-438 Type 1 Class A BORO 3.3 heat resistant glass which meets ISO 385 and USP standards. Each and every piece is calibrated to deliver. All Class A burettes are manufactured from precision bore tubing to maintain accuracy. These burettes come with either PTFE needle valve stopcocks or intermediate PTFE key stopcocks. Burettes feature printing in blue colour for better visibility.

* denotes products not stocked

Volu

metric

Gla

ssw

are

30

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Volumetric Glassware

PipettesGlassco volumetric pipettes are manufactured in compliance with DIN ISO 648 standards. These pipettes are calibrated to deliver. All volumetric pipettes are calibrated by automatic machine, and the final quality check is performed at the quality control centre. The volumetric pipettes are printed in amber colour which is fused into the glass.

Glassco Volumetric Pipettes, One Mark, Class A, as per DIN ISO 648 Standards, with Batch Certificate

Item Code Capacity Colour Code Tolerance ±mL Pack Size Unit

GLS123.202.01 1mL Blue 0.007 Each Case of 5

GLS123.202.02 2mL Orange 0.01 Each Case of 5

GLS123.202.03 5mL White 0.015 Each Case of 5

GLS123.202.04 10mL Red 0.02 Each Case of 5

GLS123.202.05 20mL Yellow 0.03 Each Case of 5

GLS123.202.06 25mL Blue 0.03 Each Case of 5

GLS123.202.07 50mL Red 0.05 Each Case of 5

GLS123.202.08 100mL Yellow 0.08 Each Case of 5

Sectio

n >>

S

ub

-Sectio

n

31

Volu

metric

Glassw

are >>

P

ipette

s

31

Glassco Volumetric Pipettes, One Mark, Class A, as per DIN ISO 648 Standards, with Batch Certificate Glassco Graduated Pipettes, Class AS, as per DIN ISO 648 Standars, with Batch Certificate

Kimble Chase Pasteur Pipettes, Disposable, Soda Lime Glass

Item Code Capacity Colour Code Tolerance ±mL Pack Size Unit

GLS125.202.01 1mL Yellow 0.007 Each Case of 5

GLS125.202.02 * 2mL Black 0.01 Each Case of 5

GLS125.202.03 5mL Red 0.03 Each Case of 5

GLS125.202.04 10mL Orange 0.05 Each Case of 5

GLS125.202.06 25mL White 0.1 Each Case of 5

Item Code Overall Length Type Tip Length Body Length OD Pack Size Unit

CSEJ5000 5.75 inch Non-plugged 2.25 inch 3.5 inch 7mm 1000pcs Each

CSEJ5000P 5.75 inch Plugged 2.25 inch 3.5 inch 7mm 1000pcs Each

CSEJ9000 9 inch Non-plugged 5 inch 4 inch 7mm 1000pcs Each

CSE63B.93P 9 inch Plugged 5 inch 4 inch 7mm 1000pcs Each

Available in Australia Only

Glassco graduated pipettes are manufactured to meet ISO 835 standards. These pipettes are calibrated to deliver. All graduated pipettes are calibrated by automatic machine, and the final quality check is performed at the quality control centre. The graduated pipettes are printed in amber colour which fuses into the glass. All Class A pipettes have a waiting time of 5 seconds.

Kimble Chase pasteur pipettes are made of disposable soda lime glass. Available sterile and non-sterile, plugged and non-plugged. For one time use in the transfer of small volumes.

* denotes products not stocked

Volu

metric

Gla

ssw

are

32

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Volumetric Glassware

Kimble Chase Pasteur Pipettes, Disposable, Soda Lime Glass

Kimble Chase Pasteur Pipettes, Sterile, Disposable, Soda Lime Glass

Item Code Overall Length Type Tip Length Body Length OD Pack Size Unit

KIM63A54 145mm Non-plugged 57mm 89mm 7mm 250pcs Each/Case of 4

KIM63A54P 145mm Plugged 57mm 89mm 7mm 250pcs Each/Case of 4

KIM63B93 230mm Non-plugged 127mm 102mm 7mm 250pcs Each/Case of 4

KIM63B93P * 230mm Plugged 127mm 102mm 7mm 250pcs Case of 4

Available in New Zealand Only

Item Code Overall Length Type Tip Length Body Length OD Pack Size Unit

KIM63A55 * 5.75 inch Non-plugged 2.25 inch 3.5 inch 7mm 250pcs Each

KIM63A55P * 5.75 inch Plugged 2.25 inch 3.5 inch 7mm 250pcs Each

KIM63B95 * 9 inch Non-plugged 5 inch 4 inch 7mm 250pcs Each

KIM63B95P * 9 inch Plugged 5 inch 4 inch 7mm 250pcs Each

* denotes products not stocked

general glassware

Kimble Chase Pasteur Pipettes, Disposable, Soda Lime Glass

Kimble Chase Pasteur Pipettes, Sterile, Disposable, Soda Lime Glass

BOD Bottles 34

Gas Washing Bottles 35

Counting Chambers 36

Weighing Scoops 37

Crystallising Dishes 37

Funnels 39

Desiccators 40

Scintillation Vials 41

Trident Vials 42

Pathological Vials 43

Petri Dishes 44

Watch Glasses 45

Separating Funnels 46

Condensers 47

Filtration Glassware 49

Jars 52

Babcock Bottles 53

Mojonnier Tubes 53

Miscellaneous 54

Microscopy 55

* denotes products not stocked

Genera

l Gla

ssw

are

34

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

34

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

BOD BottlesGlassco BOD bottles are manufactured from ASTM E-438 Type 1 Class A BORO 3.3 glass.

Glassco BOD Bottles, with Glass Stopper

Wheaton BOD Bottles

Item Code Capacity Diameter Height Pack Size Unit

GLS284.202.01 * 125mL 55mm 120mm Each Case of 2

GLS284.202.02 * 300mL 70mm 150mm Each Case of 2

Item Code Capacity Type Stopper Pack Size Unit

WHE227497 300mL Numbered 01-24 Glass robotic stopper Each Case of 24

WHE227497-02 * 300mL Numbered 25-48 Glass robotic stopper Each Case of 24

Available in New Zealand Only. Other sizes available, please contact us for further information

35

General G

lassware

>>

BO

D B

ottle

s & G

as Wash

ing B

ottle

s

3535

Gas Washing Bottles

Glassco BOD Bottles, with Glass Stopper Bottles

Heads

Wheaton BOD Bottles

Item Code Capacity Pack Size Unit

GLS286.202.01 * 125mL Each Each

GLS286.202.02 * 250mL Each Each

GLS286.202.03 * 500mL Each Each

Item Code Capacity Pack Size Unit

GLS285.202.01 * 125mL Each Each

GLS285.202.02 * 250mL Each Each

GLS285.202.03 * 500mL Each Each

* denotes products not stocked

Genera

l Gla

ssw

are

36

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

36

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Counting Chambers

Boeco Haemacytometer, Neubauer Improved Bright Line, Includes Two Cover Glasses

Schott Duran Haemacytometers, Neubauer Improved, Double Net Ruling, Includes Two Cover Glasses

Web Haemacytometer and Coverslips

Item Code Type Pack Size Unit

BOKBOE14 Double ruled Each Each

Available in Australia Only.

Item Code Type Depth Pack Size Unit

SCH8100204 * Bright lined 0.1mm Each Each

SCH8100104 * Standard 0.1mm Each Each

Item Code Type Depth Size Pack Size Unit

WEBAC1000 Standard 0.1mm Each Each

WEBZ5000 Coverslips Heamacytometer

22x25mm 10pcs Each

Available in New Zealand Only.

37

General G

lassware

>>

Countin

g C

ham

bers, W

eig

hin

g S

coop

s & C

rystalising D

ishes

3737

Weighing Scoops

Boeco Haemacytometer, Neubauer Improved Bright Line, Includes Two Cover Glasses

Glassco Weighing Scoops, with Open Tubular Arm

Schott Duran Haemacytometers, Neubauer Improved, Double Net Ruling, Includes Two Cover Glasses

Web Haemacytometer and Coverslips

Item Code Capacity Pack Size Unit

GLS245.202.01 3mL Each Case of 10

GLS245.202.02 6mL Each Case of 10

GLS245.202.03 10mL Each Case of 10

Crystallising DishesManufactured from ASTM E-438 Type 1 Class A BORO 3.3 glass. These dishes conform to DIN and USP standards. The dishes are printed in white colour and feature a white marking area for use with pencil.

Glassco Crystallising Dishes, without Spout

Item Code Diameter Height Pack Size Unit

GLS246.202.01 * 40mm 25mm Each Case of 10

GLS246.202.02 * 50mm 30mm Each Case of 10

GLS246.202.03 * 60mm 35mm Each Case of 10

GLS246.202.04 * 70mm 40mm Each Case of 10

GLS246.202.05 * 80mm 45mm Each Case of 10

GLS246.202.06 * 95mm 55mm Each Case of 10

* denotes products not stocked

Genera

l Gla

ssw

are

38

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

38

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Glassco Crystallising Dishes, with Spout

Item Code Diameter Height Pack Size Unit

GLS246.202.01S * 40mm 25mm Each Case of 10

GLS246.202.02S * 50mm 30mm Each Case of 10

GLS246.202.03S * 60mm 35mm Each Case of 10

GLS246.202.04S * 70mm 40mm Each Case of 10

GLS246.202.05S * 80mm 45mm Each Case of 10

GLS246.202.06S * 95mm 55mm Each Case of 10

39

General G

lassware

>>

Crystalisin

g D

ishers &

Funnels

3939

Glassco Crystallising Dishes, with Spout Funnels

Glassco Funnels, with Short Stem, Borosilicate Glass

Glassco Powder Funnels, Borosilicate Glass

Item Code Diameter Pack Size Unit

GLS238.202.01 25mm Each Case of 10

GLS238.202.04 40mm Each Case of 10

GLS238.202.05 50mm Each Case of 10

GLS238.202.07 65mm Each Case of 10

GLS238.202.08 70mm Each Case of 10

GLS238.202.09 75mm Each Case of 10

GLS238.202.10 80mm Each Case of 10

GLS238.202.11 100mm Each Case of 10

GLS238.202.12 * 125mm Each Case of 10

GLS238.202.13 150mm Each Case of 10

Item Code Diameter Cone Size Pack Size Unit

GLS238.202.01P * 45mm 14/23 Each Case of 10

GLS238.202.02P * 70mm 14/23 Each Case of 10

GLS238.202.03P * 70mm 29/32 Each Case of 10

GLS238.202.04P * 80mm 29/32 Each Case of 10

GLS238.202.05P * 100mm 14/23 Each Case of 10

GLS238.202.06P * 100mm 29/32 Each Case of 10

* denotes products not stocked

Genera

l Gla

ssw

are

40

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

40

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Desiccators

Glassco Desiccators, with Lid, Plain, Neutral Glass, with Porcelain Perforated Plate

Glassco Desiccators, with Lid, Vacuum, Neutral Glass, with Porcelain Perforated Plate

Item Code Internal Diameter Pack Size Unit

GLS249.202.01 * 150mm Each Each

GLS249.202.02 * 210mm Each Each

GLS249.202.03 * 250mm Each Each

GLS249.202.04 * 300mm Each Each

Item Code Internal Diameter Pack Size Unit

GLS250.202.01 * 150mm Each Each

GLS250.202.02 * 210mm Each Each

GLS250.202.03 * 250mm Each Each

GLS250.202.04 * 300mm Each Each

41

General G

lassware

>>

Desic

cato

rs & S

cintillatio

n V

ials

4141

Scintillation VialsKimble Chase scintillation vials are supplied with caps attached, in cellular trays with alpha numeric coordinates for fast, easy identification.

Glassco Desiccators, with Lid, Plain, Neutral Glass, with Porcelain Perforated Plate

Kimble Chase Scintillation Vials

Wheaton Scintillation Vials (supplied with either Polypropylene or Urea caps)

Glassco Desiccators, with Lid, Vacuum, Neutral Glass, with Porcelain Perforated Plate

Item Code Capacity Cap material Cap Liner Cap Size Pack Size Unit

KIM74502-7 7mL Urea Cork-backed foil 15mm 200pcs Case of 5

KIM74504-20 20mL Polypropylene Pulp-backed foil 22mm 500pcs Each

Item Code Capacity Cap material Cap Liner Cap Size Pack Size Unit

WHE986541 20mL Polypropylene Metal foil 22mm 500pcs Each

WHE986560 20mL Polypropylene Foamed polyethylene 24mm 500pcs Each

WHE986561 20mL Polypropylene Metal foil 22mm 500pcs Each

WHE986542 20mL Urea Metal foil 22mm 500pcs Each

WHE986546 20mL Urea Polyseal 22mm 500pcs Each

WHE986548 20mL Urea Polyethylene disc 22mm 500pcs Each

Available in New Zealand Only.

* denotes products not stocked

Genera

l Gla

ssw

are

42

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

42

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Trident VialsSamco neutral glass vials will withstand moderate temperature change.

Samco Trident Vials, Neutral Glass, without Closure

Item Code Capacity Form Height x Diameter Neck Bore Pack Size Unit

SAMT101/V1 * 1.75mL Tall Form 36x11mm 5.5mm 882pcs Each

SAMT101/V2 * 3.5mL Tall Form 46x12.5mm 5.5mm 666pcs Each

SAMT101/V3 * 7.0mL Tall Form 58x17mm 9.0mm 399pcs Each

SAMT101/V4 * 10.5mL Tall Form 67x17mm 9.0mm 399pcs Each

SAMT101/V5 * 14.0mL Tall Form 72x20mm 13.0mm 264pcs Each

SAMT101/V6 * 21.25mL Tall Form 86x21mm 13.0mm 231pcs Each

SAMT101/V7 * 28.25mL Tall Form 96x23mm 15.5mm 190pcs Each

SAMT102/V1 * 7.0mL Squat Form 42x20mm 13.0mm 264pcs Each

SAMT102/V2 * 14.0mL Squat Form 58x23mm 15.5mm 190pcs Each

SAMT102/V3 28.25mL Squat Form 27.5x21mm 21.0mm 140pcs Each

43

General G

lassware

>>

Trident &

Path

olo

gy V

ials

4343

Pathological VialsSamco moulded pathological vials are made of white flint glass, which has been sulphated for autoclaving. Spare caps are also available.

Samco Trident Vials, Neutral Glass, without Closure

Samco Pathological Vials, White Flint Glass, with Fitted Aluminium Rubber Lined Closure

Samco Screw Caps for Trident Vials, Black Polypropylene, Foil-faced Wads

Item Code Capacity Type Neck Height x Diameter Pack Size Unit

SAMG752/01 7.0mL Bijou Narrow Neck 48.5x21.9mm 288pcs Each

SAMG752/02 * 14.0mL McCartney Narrow Neck 64.7x27.6mm 288pcs Each

SAMG751/01 28.0mL Universal Wide Neck 82.5x28.6mm 144pcs Each

Item Code Capacity Pack Size Unit

SAMT001/C1 To fit T101/V1 and T101/V2 882pcs Each

SAMT001/C3 * To fit T101/V3 and T101/V4 399pcs Each

SAMT001/C5 * To fit T101/V5, T101/V6 and T102/V1 264pcs Each

SAMT001/C7 * To fit T101/V7 and T102/V2 190pcs Each

SAMT002/C3 To fit T102/V3 140pcs Each

* denotes products not stocked

Genera

l Gla

ssw

are

44

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

44

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Petri DishesKIMAX dishes have reinforced beaded edges to resist mechanical breakage and to help in centering the bottom inside the cover. Dishes remain clear after repeated use in wet or dry sterilisation cycles. Shelf packs contain twelve covers and twelve bottoms, which are packed in separate boxes. Designed from Federal Specification NNN-D-1478.

Kimble Petri Dishes

Schott Duran Petri Dishes, Steriplan, Soda Lime Glass

Item Code Diameter Height Pack Size Unit

KIM23060-6015 60mm 15mm Each Each/Pack of 12/Case of 72

KIM23060-10020 100mm 20mm Each Each/Pack of 12/Case of 72

KIM23060-15020 * 150mm 20mm Each Case of 24

Item Code Diameter Height Pack Size Unit

SCH2375539 * 40mm 12mm Each Case of 10

SCH2375540 60mm 15mm Each Case of 10

SCH2375542 * 80mm 15mm Each Case of 10

SCH2375545 * 100mm 10mm Each Case of 10

SCH2375546 100mm 15mm Each Case of 10

SCH2375548 * 100mm 20mm Each Case of 10

SCH2375551 * 120mm 20mm Each Case of 10

SCH2375552 * 150mm 25mm Each Case of 10

SCH2375556 * 180mm 30mm Each Case of 10

SCH2375559 * 200mm 30mm Each Case of 10

SCH2375561 * 200mm 50mm Each Case of 10

45

General G

lassware

>>

Petri D

ishers &

Watc

h G

lasses

4545

Watch Glasses

Kimble Petri Dishes

Schott Duran Watch Glasses, with Fused Rim, Soda Lime Glass

Schott Duran Petri Dishes, Steriplan, Soda Lime Glass

Item Code Diameter Pack Size Unit

SCH2332124 * 40mm Each Case of 10

SCH2332132 * 50mm Each Case of 10

SCH2332134 * 60mm Each Case of 10

SCH2332138 * 70mm Each Case of 10

SCH2332141 * 80mm Each Case of 10

SCH2332143 * 90mm Each Case of 10

SCH2332146 * 100mm Each Case of 10

SCH2332151 * 120mm Each Case of 10

SCH2332152 * 125mm Each Case of 10

SCH2332157 * 150mm Each Case of 10

SCH2332161 * 200mm Each Case of 10

SCH2332166 * 250mm Each Each

* denotes products not stocked

Genera

l Gla

ssw

are

46

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

46

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Separating FunnelsGlassco separating funnels are produced from ASTM E-438 Type 1 Class A BORO 3.3 heat resistant glass. All Glassco funnels are manufactured as per ISO 4800 standard. The printing is done in white colour.

Glassco Squibb Separating Funnels, Plain, PTFE Stopcock

Glassco Cylindrical Dropping Funnels, Graduated, PTFE Stopcock

Glassco Pear Separating Funnels, Plain, PTFE Stopcock

Item Code Capacity Stopper Size Bore Pack Size Unit

GLS149.202.02 * 50mL 19/26 2.5mm Each Each

GLS149.202.03 100mL 19/26 2.5mm Each Each

GLS149.202.04 250mL 29/32 4mm Each Each

GLS149.202.05 500mL 29/32 4mm Each Each

GLS149.202.06 1,000mL 29/32 6mm Each Each

GLS149.202.07 2,000mL 29/32 6mm Each Each

Item Code Capacity Stopper Size Bore Pack Size Unit

GLS158.202.04 * 250mL 29/32 4mm Each Each

GLS158.202.05 * 500mL 29/32 4mm Each Each

GLS158.202.06 * 1,000mL 29/32 6mm Each Each

Item Code Capacity Stopper Size Bore Pack Size Unit

GLS152.202.02 * 50mL 19/26 2.5mm Each Each

GLS152.202.03 100mL 19/26 2.5mm Each Each

GLS152.202.05 500mL 29/32 4mm Each Each

GLS152.202.06 1,000mL 29/32 6mm Each Each

GLS152.202.07 * 2,000mL 29/32 6mm Each Each

47

General G

lassware

>>

Sep

arating Fu

nnels &

Cond

ense

rs

4747

Condensers

Glassco Squibb Separating Funnels, Plain, PTFE StopcockGlassco Liebig Condensers, Glass Hose Connections

Glassco Coil Condensers, Glass Hose Connections

Glassco Cylindrical Dropping Funnels, Graduated, PTFE Stopcock

Glassco Pear Separating Funnels, Plain, PTFE Stopcock

Item Code Effective Length Cone Size Socket Size Pack Size Unit

GLS182.202.01 160mm 14/23 14/23 Each Each

GLS182.202.01A * 160mm 19/26 19/26 Each Each

GLS182.202.02 250mm 19/26 19/26 Each Each

GLS182.202.03 250mm 24/29 24/29 Each Each

GLS182.202.04 * 300mm 19/26 19/26 Each Each

GLS182.202.05 * 300mm 24/29 24/29 Each Each

GLS182.202.06 * 300mm 29/32 29/32 Each Each

GLS182.202.10 * 400mm 24/29 24/29 Each Each

GLS182.202.11 * 400mm 29/32 29/32 Each Each

Item Code Effective Length Cone Size Socket Size Pack Size Unit

GLS183.202.01 * 160mm 14/23 14/23 Each Each

GLS183.202.01A * 160mm 19/26 19/26 Each Each

GLS183.202.03 * 250mm 19/26 19/26 Each Each

GLS183.202.04 * 250mm 24/29 24/29 Each Each

GLS183.202.04A * 250mm 29/32 29/32 Each Each

GLS183.202.05 * 300mm 24/29 24/29 Each Each

GLS183.202.06 * 300mm 29/32 29/32 Each Each

GLS183.202.07 * 400mm 29/32 29/32 Each Each

* denotes products not stocked

Genera

l Gla

ssw

are

48

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

48

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Glassco Allihn Condensers, Glass Hose Connections

Soxhlet Extractors

Item Code Effective Length Cone Size Socket Size Pack Size Unit

GLS190.202.05 * 160mm 14/23 14/23 Each Each

GLS190.202.06 * 160mm 19/26 19/26 Each Each

GLS190.202.07 * 250mm 14/23 14/23 Each Each

GLS190.202.08 * 250mm 19/26 19/26 Each Each

GLS190.202.09 * 250mm 24/29 24/29 Each Each

GLS190.202.10 * 300mm 24/29 24/29 Each Each

GLS190.202.11 * 300mm 29/32 29/32 Each Each

GLS190.202.12 * 400mm 24/29 24/29 Each Each

GLS190.202.13 * 400mm 29/32 29/32 Each Each

Item Code Capacity Cone Size Socket Size Pack Size Unit

GLS211.202.04 * 100mL 29/32 45/40 Each Each

GLS211.202.05 * 150mL 29/32 45/40 Each Each

GLS211.202.06 * 250mL 29/32 45/40 Each Each

GLS211.202.08 * 500mL 29/32 60/46 Each Each

GLS211.202.09 * 1,000mL 29/32 71/51 Each Each

49

General G

lassware

>>

Cond

ense

rs & F

iltration G

lassware

4949

Glassco Allihn Condensers, Glass Hose Connections

Soxhlet Extractors

Filtration Glassware

Glassco Filtration Assembly, 47mm, All Glass, with Funnel, Fritted Base, Cap and Clamp

Millipore Glass Filter Holders, Borosilicate Glass Funnel and Base, Anodised Aluminium Spring Clamp, Silicone Stopper

Item Code Funnel Flask Filter Diameter Pack Size Unit

GLS258.202.01 300mL 1,000mL 47mm Each Each

Item Code Part Funnel Capacity Filter Diameter Pack Size Unit

MILXX1004700 Coarse-frit glass filter support 300mL 47mm Each Each

MILXX1004710 PTFE-faced funnel and base 300mL 47mm Each Each

* denotes products not stocked

Genera

l Gla

ssw

are

50

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

50

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Glassco Filter Gooch Crucibles, with Sintered Disc, Borosilicate Glass

Item Code Capacity Porosity Pack Size Unit

GLS255.G00.01 * 15mL 0 Each Case of 10

GLS255.G01.01 * 15mL 1 Each Case of 10

GLS255.G02.01 * 15mL 2 Each Case of 10

GLS255.G03.01 * 15mL 3 Each Case of 10

GLS255.G04.01 * 15mL 4 Each Case of 10

GLS255.G00.02 * 30mL 0 Each Case of 10

GLS255.G01.02 * 30mL 1 Each Case of 10

GLS255.G02.02 * 30mL 2 Each Case of 10

GLS255.G03.02 * 30mL 3 Each Case of 10

GLS255.G04.02 * 30mL 4 Each Case of 10

GLS255.G00.03 * 50mL 0 Each Case of 10

GLS255.G01.03 * 50mL 1 Each Case of 10

GLS255.G02.03 * 50mL 2 Each Case of 10

GLS255.G03.03 * 50mL 3 Each Case of 10

GLS255.G04.03 * 50mL 4 Each Case of 10

51

General G

lassware

>>

Filtratio

n G

lassware

5151

Glassco Filter Gooch Crucibles, with Sintered Disc, Borosilicate Glass Glassco Buchner Funnels, with Sintered Disc, Borosilicate Glass

Item Code Capacity Porosity Pack Size Unit

GLS256.G00.01 * 35mL 0 Each Case of 2

GLS256.G01.01 * 35mL 1 Each Case of 2

GLS256.G02.01 * 35mL 2 Each Case of 2

GLS256.G03.01 * 35mL 3 Each Case of 2

GLS256.G04.01 * 35mL 4 Each Case of 2

GLS256.G00.02 * 80mL 0 Each Case of 2

GLS256.G01.02 * 80mL 1 Each Case of 2

GLS256.G02.02 * 80mL 2 Each Case of 2

GLS256.G03.02 * 80mL 3 Each Case of 2

GLS256.G04.02 * 80mL 4 Each Case of 2

GLS256.G00.03 * 200mL 0 Each Case of 2

GLS256.G01.03 * 200mL 1 Each Case of 2

GLS256.G02.03 * 200mL 2 Each Case of 2

GLS256.G03.03 * 200mL 3 Each Case of 2

GLS256.G04.03 * 200mL 4 Each Case of 2

GLS256.G00.04 * 500mL 0 Each Case of 2

GLS256.G01.04 * 500mL 1 Each Case of 2

GLS256.G02.04 * 500mL 2 Each Case of 2

GLS256.G03.04 * 500mL 3 Each Case of 2

GLS256.G04.04 * 500mL 4 Each Case of 2

GLS256.G00.05 * 1,000mL 0 Each Case of 2

GLS256.G01.05 * 1,000mL 1 Each Case of 2

GLS256.G02.05 * 1,000mL 2 Each Case of 2

GLS256.G03.05 * 1,000mL 3 Each Case of 2

GLS256.G04.05 * 1,000mL 4 Each Case of 2

* denotes products not stocked

Genera

l Gla

ssw

are

52

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

52

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Jars

Cospak Clear Jars, Caps Sold Separately

Item Code Type Capacity Neck Finish Height Diameter Pack Size Unit

COSH0466 * Clear jar 30mL 38mm 46mm 40mm 160pcs Each

COSTG1146 * Clear jar 125mL 48mm 42pcs Each

COSH15131 Clear jar 250mL 63mm 104mm 67mm 48pcs Each

COSJA500C * Clear jar 500mL 63mm 148mm 78mm 50pcs Each

COS3830 White poly cap 38mm Each Each

COS4832 * Black phenolic wadded cap 48mm Each Each

COS6330 * White poly cap 63mm Each Each

COS6331 * White poly wadded cap 63mm Each Each

Available in Australia Only

Solindex Jars

Item Code Type Pack Size Unit

LABSOL003 Jar solindex Each Each/Case of 25

LABSOL001 * Mixing unit for ADMI solindex Each Each

LABSOL002 * Solindex blades Each Each

LABSOL003 Jar solindex Each Each/Case of 25

Available in New Zealand Only

53

General G

lassware

>>

Jars & M

ore

5353

Cospak Clear Jars, Caps Sold Separately

Solindex Jars

Kimble Chase Babcock Bottles

Item Code Type Pack Size Unit

KIM509-50 * 50% 9g paley cheese Each Case of 3

KIM2085S-50 * Cream test 9g sealed Each Case of 12

Available in Australia Only

Babcock Bottles

Funke Gerber Mojonnier Tubes

Mojonnier Flasks

Item Code Type Stopper Pack Size Unit

FG3870 Round bulb Cork Each Each

FG3871 Flat topped bulb Cork Each Each

Available in New Zealand Only

Item Code Type Pack Size Unit

PEDMAJSTD * Medium wall Each Each

Available in Australia Only

Mojonnier Tubes

* denotes products not stocked

Genera

l Gla

ssw

are

54

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

54

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

Item Code Type Pack Size Unit

CSUROD 6x200mm Each Each/Case of 10

Available in New Zealand Only

RBI434408 6x300mm Each Each

Available in Australia Only

Item Code Type Volume Cone Pack Size Unit

CSUTILT/10 Tilt measure 10mL 24/29 Each Each

CSUWBOAT.10 Weighing boat glass 10mL Each Each

Available in New Zealand Only

Stirring Rods

Miscellaneous

55

General G

lassware

>>

Stirrin

g R

od

s, Misc

ellan

eous &

Mic

rosc

op

e S

lides

5555

LabServ Microscope Slides• LabServ microscope slides are cut from water white, corrosion resistant glass

• All slides have ground and polished edges to prevent injury to fingers

• Superfrost and Colorfrost slides have a permanent opaque frosted area which makes written information permanent and easier to read

• Pre-cleaned

• Individually selected

• Annealed to minimise chipping and breakage

• Thin, flat and resistant to corrosion or fogging

Microscope Slides

Item Code Type Dimensions mm Pack Size Unit

LBS2950RC Plain 75x25mm 100pcs Each

LBS2951RC Frosted 75x25mm 100pcs Each

LBS4951 Superfrost white 75x25mm 100pcs Each/Case of 35

LBS6951 Colorfrost green 75x25mm 100pcs Each/Case of 35

LBS7951 Colorfrost pink 75x25mm 100pcs Each/Case of 35

LBS8951 Colorfrost yellow 75x25mm 100pcs Each/Case of 35

LBSP4981 Polysine frosted 75x25mm 72pcs Each

LBS4951PLUS Superfrost plus 75x25mm 72pcs Each

* denotes products not stocked

Genera

l Gla

ssw

are

56

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

56

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

General Glassware

LabServ Coverslips

Item Code Type Dimensions mm Pack Size Unit

LBS18X18-1 Coverslip No 1 18x18mm 242pcs Each/Case of 10

LBS22X22-1 Coverslip No 1 22x22mm 162pcs Each/Case of 10

LBS22X30-1 Coverslip No 1 22x30mm 119pcs Each/Case of 10

LBS22X40-1 Coverslip No 1 22x40mm 89pcs Each/Case of 10

LBS22X50-1 Coverslip No 1 22x50mm 62pcs Each/Case of 10

LBS22X60-1 Coverslip No 1 22x60mm 59pcs Each/Case of 10

LBS24X50-1 Coverslip No 1 24x50mm 65pcs Each/Case of 10

* denotes products not stocked

LabServ Coverslips

Culture Tubes 58

Closures 62

Centrifuge Tubes 63

Specimen Tubes 64

Durham Tubes 65

Haematocrit Tubes 65

NMR Tubes 66

specialty tubestest,culture &

* denotes products not stocked

Test

, C

ultu

re &

Specia

lty T

ubes

58

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

58

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

58

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Test, Culture & Specialty Tubes

Disposable Culture TubesThe LabServ borosilicate rimless disposable culture tubes have a low thermal expansion coefficient and high chemical resistance, making them ideal for use in the medical, pharmaceutical and analytical industries. The LabServ borosilicate rimless disposable culture tubes conform to USP, Type I and ASTM Type I, Class B standards and are available in a wide range of sizes from 6x50mm to 25x150mm.

Borosilicate glass KIMAX-51 composition assures the best all-around chemical durability of commercial glasses now available for laboratory ware. Complies with ASTM Specification E438, Type I, Class B glass requirements. KIMAX-51 has excellent chemical resistance against sodium leaching - a factor common in soda lime glass products. These are premium quality tubes with sturdy, uniform bottoms and consistent lengths. The 10 and 12 x 75 mm sizes are suitable for cell washing procedures. Tubes are packed in convenient trays for ease of use on bench tops and in drawers. The 10 and 12 x 75 mm sizes fit into Kimble 73510 stainless steel dispensers. The 6 x 50 mm size is often referred to as a “Durham tube”. Trays are shrink wrapped in plastic film with tubes remaining in constant alignment for protection against in-transit breakage and contamination. Designed from ASTM Specification E890.

LabServ Disposable Culture Tubes, Borosilicate Glass, Rimless

Item Code Diameter x Height Pack Size Unit

LBSDCT650 6x50mm 500pcs Each/Case of 8

LBSDCT1075 10x75mm 250pcs Each/Case of 6

LBSDCT1275 12x75mm 250pcs Each/Case of 6

LBSDCT13100 13x100mm 250pcs Each/Case of 6

LBSDCT16100 16x100mm 250pcs Each/Case of 4

LBSDCT16125 16x125mm 250pcs Each/Case of 4

LBSDCT16150 16x150mm 250pcs Each/Case of 4

LBSDCT18150 18x150mm 125pcs Each/Case of 4

LBSDCT20150 * 20x150mm 125pcs Case of 4

LBSDCT25150 * 25x150mm 50pcs Case of 6

Available in Australia Only

* denotes products not stocked 5959

Test, Cultu

re &

Specially Tub

es >>

Disp

osab

le C

ultu

re Tu

bes

5959

Kimble Chase Disposable Culture Tubes, Borosilicate Glass, Rimless

Item Code Diameter x Height Pack Size Unit

CSE73500-650 6x50mm 1000pcs Each

CSE73500-1075 10x75mm 1000pcs Each

CSE73500-1275 12x75mm 1000pcs Each

CSE73500-13100 13x100mm 1000pcs Each

CSE73500-16100 16x100mm 1000pcs Each

CSE73500-16125 16x125mm 1000pcs Each

CSE73500-16150 16x150mm 1000pcs Each

CSE73500-18150 18x150mm 500pcs Each

CSE73500-20150 * 20x150mm 500pcs Each

CSE73500-25150 25x150mm 500pcs Each

Available in Australia Only

Kimble Chase Disposable Culture Tubes, Borosilicate Glass, Rimless

Item Code Diameter x Height Pack Size Unit

KIM73500-650 6x50mm 500pcs Case of 2

KIM73500-1075 10x75mm 250pcs Each/Case of 4

KIM73500-1275 12x75mm 250pcs Each/Case of 4

KIM73500-13100 13x100mm 250pcs Each/Case of 4

KIM73500-16100 16x100mm 250pcs Each/Case of 4

KIM73500-16125 16x125mm 250pcs Each/Case of 4

KIM73500-16150 16x150mm 250pcs Case of 4

KIM73500-18150 18x150mm 125pcs Each/Case of 4

KIM73500-18150 18x150mm 125pcs Each/Case of 4

KIM73500-20150 20x150mm 125pcs Case of 4

KIM73500-25150 25x150mm 125pcs Case of 4

Available in New Zealand Only

LabServ Disposable Culture Tubes, Borosilicate Glass, Rimless

* denotes products not stocked

Test

, C

ultu

re &

Specia

lty T

ubes

60

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

60

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

60

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Test, Culture & Specialty Tubes

Reusable Culture TubesKIMAX culture tubes are made from KG-33 glass tubing, with fire-polished top rims and uniform wall thickness for maximum heat transfer and chemical resistance. Durable white ceramic enamel marking spot. Designed from ASTM Specification E982, Type IV requirements.

Kimble Chase Reusable Culture Tubes, with Rim

Item Code Diameter x Height Overflow Capacity Pack Size Unit

KIM45048-1075 * 10x75mm 4mL 72pcs Case of 10

KIM45048-1275 * 12x75mm 6mL 72pcs Case of 10

KIM45048-13100 13x100mm 10mL 72pcs Case of 10

KIM45048-16100 * 16x100mm 15mL 72pcs Case of 8

KIM45048-16125 * 16x125mm 20mL 72pcs Case of 8

KIM45048-16150 16x150mm 24mL 72pcs Case of 8

KIM45048-18150 18x150mm 28mL 72pcs Case of 8

KIM45048-20150 * 20x150mm 36mL 72pcs Case of 4

KIM45048-25150 * 25x150mm 55mL 72pcs Case of 4

* denotes products not stocked 6161

Test, Cultu

re &

Specially Tub

es >>

Reusab

le C

ultu

re Tu

bes

6161

KIMAX culture tubes are made from tubing with uniform wall thickness for maximum heat transfer and chemical resistance. Thread finish complies with Glass Packaging Institute (GPI) requirements. Cap has a PTFE-faced rubber liner and is not attached. Designed from ASTM E982, Type VI, Class B requirements.

Kimble Chase Reusable Culture Tubes, with PTFE-Faced Rubber Liner Threaded Cap Unattached

Item Code Diameter x Height Overflow Capacity Pack Size Unit

KIM45066A-13100 * 13x100mm 8mL 72pcs Case of 4

KIM45066A-16100 * 16x100mm 12mL 72pcs Case of 4

KIM45066A-16125 * 16x125mm 16mL 72pcs Case of 4

KIM45066A-16150 * 16x150mm 20mL 72pcs Case of 4

KIM45066A-20125 * 20x125mm 25mL 48pcs Case of 4

KIM45066A-20150 * 20x150mm 30mL 48pcs Case of 4

KIM45066A-25150 * 25x150mm 50mL 36pcs Case of 4

Kimble Chase Reusable Culture Tubes, with Rim

* denotes products not stocked

Test

, C

ultu

re &

Specia

lty T

ubes

62

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

62

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

62

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Test, Culture & Specialty Tubes

Test Tube ClosuresClosures for culture tubes and flasks. Colour Coded - natural, red, green, yellow and blue available.

Kimble Chase KIM-KAP, Polypropylene

Item Code Colour Diameter Pack Size Unit

KIM73660-13 * Natural 13mm 500pcs Case of 2

KIM73660-16 * Natural 16mm 500pcs Case of 2

KIM73660-18 * Natural 18mm 500pcs Case of 2

KIM73660-20 * Natural 20mm 250pcs Case of 2

KIM73660-25 * Natural 25mm 250pcs Case of 2

KIM73660-38 * Natural 38mm 125pcs Case of 2

* denotes products not stocked 6363

Test, Cultu

re &

Specially Tub

es >>

Test Tu

bes C

losu

res &

Centrifu

ge Tu

bes

6363

Centrifuge Tubes

Glassco Centrifuge Tubes, Conical Bottom, Graduated

Glassco Centrifuge Tubes, Conical Bottom, Plain

Glassco Centrifuge Tubes, Round Bottom, Graduated

Item Code OD x height Capacity Pack Size Unit

GLS088.202.01 * 13x100mm 5mL 50pcs Each

GLS088.202.02 * 15x110mm 10mL 50pcs Each

GLS088.202.03 * 17x120mm 15mL 50pcs Each

GLS088.202.04 * 22x125mm 25mL 50pcs Each

GLS088.202.05 * 28x125mm 50mL 50pcs Each

Item Code OD x height Capacity Pack Size Unit

GLS089.202.02 * 13x100mm 5mL 50pcs Each

GLS089.202.03 * 15x110mm 10mL 50pcs Each

GLS089.202.05 * 17x120mm 15mL 50pcs Each

GLS089.202.06 * 22x125mm 25mL 50pcs Each

GLS089.202.07 * 28x125mm 50mL 50pcs Each

Item Code OD x height Capacity Pack Size Unit

GLS094.202.01 * 16x110mm 12mL 50pcs Each

GLS094.202.02 * 24x110mm 30mL 50pcs Each

GLS094.202.03 * 28x110mm 40mL 50pcs Each

GLS094.202.04 * 30x110mm 50mL 50pcs Each

GLS094.202.05 * 45x110mm 100mL 50pcs Each

GLS094.202.07 * 55x116mm 200mL 50pcs Each

Kimble Chase KIM-KAP, Polypropylene

* denotes products not stocked

Test

, C

ultu

re &

Specia

lty T

ubes

64

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

64

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

64

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Test, Culture & Specialty Tubes

Specimen TubesSamco Specimen Tubes, Soda Glass, Flat Bottom, with Polyethylene Push Cap

Item Code Diameter x Height Wall Thickness Pack Size Unit

SAMG050/17 * 10x38mm 0.6mm 250pcs Each

SAMG050/18 * 10x50mm 0.6mm 250pcs Each

SAMG050/19 * 12x38mm 0.85mm 100pcs Each

SAMG050/20 12x50mm 0.85mm 100pcs Each

SAMG050/22 * 12x75mm 0.85mm 100pcs Each

SAMG050/24 16x50mm 0.85mm 100pcs Each

SAMG050/25 * 16x75mm 0.85mm 100pcs Each

SAMG050/26 19x50mm 0.85mm 100pcs Each

SAMG050/27 * 19x75mm 0.85mm 100pcs Each

SAMG050/28 25x50mm 0.85mm 100pcs Each

SAMG050/29 * 25x75mm 0.85mm 100pcs Each

SAMG050/30 * 25x100mm 0.85mm 100pcs Each

SAMG050/31 * 25x150mm 0.85mm 100pcs Each

* denotes products not stocked 6565

Test, Cultu

re &

Specially Tub

es >>

Sp

ecim

en Tu

bes &

More

6565

Durham TubesSamco neutral glass test tubes will withstand moderate temperature change.

Haematocrit TubesKimble Chase brand micro-haematocrit tubes are manufactured from soda lime glass, packed in plastic vials with reclosable snap-lock caps to maintain cleanliness. Ends may be sealed by flame, sealing clay or patented caps. They are available in borosilicate glass as a special order. Heparinised capillary tubes are treated to prevent blood clotting. Ammonium Heparin does not interfere with sodium identification.

Samco Durham Tubes, Neutral Glass

Kimble Chase Haematocrit Tubes

Item Code Diameter x Height Wall Thickness Pack Size Unit

SAMG010/21 6.5x25mm 0.65mm 250pcs Each

SAMG010/22 * 6.5x30mm 0.65mm 250pcs Each

SAMG010/23 * 7.5x35mm 0.65mm 250pcs Each

SAMG010/24 * 7.5x50mm 0.65mm 250pcs Each

Item Code Type Width (mm) Pack Size Unit

CSE2501 Heparin 75 200pcs Each/Case of 12

CSE2502 Plain 75 200pcs Each/Case of 12

Samco Specimen Tubes, Soda Glass, Flat Bottom, with Polyethylene Push Cap

* denotes products not stocked

Test

, C

ultu

re &

Specia

lty T

ubes

66

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Test, Culture & Specialty Tubes

NMR TubesKontes thrift tubes are manufactured from KIMAX® N-51A borosilicate glass and their performance is assured by state of the art manufacturing and inspection processes for camber and concentricity. Caps attached.

Kontes NMR Tubes, Thrift Quality, 5mm, N-51A Borosilicate Glass, Caps Attached

Item CodeApprox. Frequency (MHz)

Length (in) Wall Thickness Pack Size Unit

KON897150-0007 * 500 7 0.38mm 5pcs Each

KON897150-0008 * 500 8 0.38mm 5pcs Each

KON897140-0007 * 400 7 0.38mm 5pcs Each

KON897140-0008 * 400 8 0.38mm 5pcs Each

KON897130-0007 * 300 7 0.38mm 5pcs Each

KON897130-0008 * 300 8 0.38mm 5pcs Each

KON897120-0007 * 200 7 0.38mm 5pcs Each

KON897110-0007 * >200 7 0.38mm 5pcs Each

KON897110-0008 * >200 8 0.38mm 5pcs Each

* denotes products not stocked

interchangeable glassware

Flasks 68

Stoppers 74

Adapters 75

Kontes NMR Tubes, Thrift Quality, 5mm, N-51A Borosilicate Glass, Caps Attached

* denotes products not stocked

Inte

rchan

geab

le G

lass

war

e

68

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Interchangeable Glassware

Flasks Glassco flasks are manufactured from ASTM 438 Type 1 Class BORO 3.3 heat resistant glass. All come with thick uniform wall thickness and are printed with white enamel. All flasks comply to their respective DIN/ISO/ASTM and USP standards.

Glassco Round Bottom Flasks, Single Neck

Item Code Capacity Socket SizeApprox. Overall Height

Diameter Pack Size Unit

GLS057.202.05 25mL 14/23 65mm 33mm Each Case of 10

GLS057.202.06 25mL 19/26 85mm 41mm Each Case of 10

GLS057.202.08 50mL 14/23 90mm 51mm Each Case of 10

GLS057.202.09 50mL 19/26 90mm 51mm Each Case of 10

GLS057.202.10 50mL 24/29 115mm 51mm Each Case of 10

GLS057.202.11 100mL 14/23 105mm 64mm Each Case of 10

GLS057.202.12 100mL 19/26 105mm 64mm Each Case of 10

GLS057.202.13 100mL 24/29 105mm 64mm Each Case of 10

GLS057.202.20 250mL 14/23 140mm 85mm Each Case of 10

GLS057.202.21 250mL 19/26 140mm 85mm Each Case of 10

GLS057.202.22 250mL 24/29 140mm 85mm Each Case of 10

GLS057.202.25 500mL 19/26 163mm 105mm Each Case of 10

GLS057.202.30 1,000mL 24/29 200mm 131mm Each Case of 10

* denotes products not stocked

Interchangeab

le G

lassware

>>

Flasks

69

Glassco Round Bottom Flasks, Two Necks

Item Code Capacity Centre Socket Size Side Socket Size Pack Size Unit

GLS059.202.01 * 50mL 24/29 14/23 Each Each

GLS059.202.02 * 50mL 29/32 14/23 Each Each

GLS059.202.03 100mL 24/29 14/23 Each Each

GLS059.202.04 100mL 24/29 19/26 Each Each

GLS059.202.05 * 100mL 29/32 14/23 Each Each

GLS059.202.06 250mL 24/29 14/23 Each Each

GLS059.202.07 250mL 24/29 19/26 Each Each

GLS059.202.08 * 250mL 29/32 14/23 Each Each

GLS059.202.09 * 500mL 24/29 14/23 Each Each

GLS059.202.10 * 500mL 24/29 19/26 Each Each

GLS059.202.11 * 500mL 29/32 14/23 Each Each

GLS059.202.12 * 1,000mL 24/29 14/23 Each Each

GLS059.202.13 * 1,000mL 24/29 19/26 Each Each

GLS059.202.14 * 1,000mL 29/32 14/23 Each Each

GLS059.202.15 * 2,000mL 34/35 19/26 Each Each

Glassco Round Bottom Flasks, Single Neck

* denotes products not stocked

Inte

rchan

geab

le G

lass

war

e

70

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Interchangeable Glassware

Glassco Round Bottom Flasks, Three Necks, Angular

Item Code Capacity Centre Socket Size Side Socket Size Pack Size Unit

GLS060.202.01 * 100mL 19/26 14/23 Each Each

GLS060.202.02 * 100mL 24/29 14/23 Each Each

GLS060.202.03 * 100mL 24/29 19/26 Each Each

GLS060.201.03A * 100mL 29/32 14/23 Each Each

GLS060.202.04 * 250mL 19/26 19/26 Each Each

GLS060.202.05 250mL 24/29 14/23 Each Each

GLS060.202.06 * 250mL 24/29 19/26 Each Each

GLS060.202.07 * 250mL 29/32 14/23 Each Each

GLS060.202.08 * 250mL 29/32 19/26 Each Each

GLS060.201.08A * 250mL 29/32 29/32 Each Each

GLS060.202.09 * 500mL 24/29 14/23 Each Each

GLS060.202.10 * 500mL 24/29 19/26 Each Each

GLS060.202.11 * 500mL 29/32 14/23 Each Each

GLS060.202.12 * 500mL 29/32 19/26 Each Each

GLS060.201.12A * 500mL 29/32 29/32 Each Each

GLS060.202.13 * 1,000mL 24/29 14/23 Each Each

GLS060.202.14 * 1,000mL 24/29 19/26 Each Each

GLS060.202.15 * 1,000mL 29/32 14/23 Each Each

GLS060.202.16 * 1,000mL 29/32 19/26 Each Each

GLS060.202.17 * 1,000mL 29/32 29/32 Each Each

GLS060.202.18 * 2,000mL 24/29 19/26 Each Each

GLS060.202.19 * 2,000mL 29/32 24/29 Each Each

GLS060.202.20 * 2,000mL 29/32 29/32 Each Each

* denotes products not stocked

Volu

metric

Glassw

are >>

Flasks

71

Pear Shaped Flasks, Single Neck

Evaporating Flasks

Pear Shaped Flasks, Two Necks

Item Code Capacity Socket Size Approx. DiameterApprox. Overall Height

Pack Size Unit

GLS062.202.06 * 25mL 14/23 38mm 90mm Each Case of 10

GLS062.202.07 * 50mL 14/23 48mm 110mm Each Case of 10

GLS062.202.09 * 100mL 14/23 58mm 125mm Each Case of 10

Item Code Capacity Socket SizeApprox. Overall Height

Pack Size Unit

GLS069.202.01 * 50mL 29/32 94mm Each Case of 10

GLS069.202.02 * 100mL 24/29 110mm Each Case of 10

GLS069.202.03 * 100mL 29/32 110mm Each Case of 10

GLS069.202.04 * 250mL 24/29 140mm Each Case of 10

GLS069.202.05 * 250mL 29/32 140mm Each Case of 10

GLS069.202.06 * 500mL 24/29 170mm Each Case of 10

GLS069.202.07 * 500mL 29/32 170mm Each Case of 10

GLS069.202.08 * 1,000mL 24/29 210mm Each Case of 10

GLS069.202.09 * 1,000mL 29/32 210mm Each Case of 10

GLS069.202.10 * 2,000mL 29/32 250mm Each Case of 6

Item Code CapacityCentre Socket Size

Side Socket Size

Approx. Overall Height

Pack Size Unit

GLS063.202.01 * 50mL 14/23 14/23 110mm Each Each

GLS063.202.02 * 100mL 14/23 14/23 125mm Each Each

Glassco Round Bottom Flasks, Three Necks, Angular

* denotes products not stocked

Inte

rchan

geab

le G

lass

war

e

72

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Interchangeable Glassware

Kjeldahl Flasks

Item Code Capacity Socket Size Approx. Height Pack Size Unit

GLS070.202.01 * 50mL 19/26 162mm Each Case of 2

GLS070.202.02 * 100mL 19/26 162mm Each Case of 2

GLS070.202.03 * 100mL 24/29 265mm Each Case of 2

GLS070.202.04 * 300mL 24/29 295mm Each Case of 2

GLS070.202.05 * 500mL 24/29 305mm Each Case of 2

GLS070.202.06 * 800mL 24/29 325mm Each Each

* denotes products not stocked

Volu

metric

Glassw

are >>

Flasks

73

Conical Flasks

Item Code Capacity Socket SizeApprox. Overall Diameter

Approx. Overall Height

Pack Size Unit

GLS071.202.06 * 25mL 14/23 75mm 42mm Each Case of 10

GLS071.202.07 * 25mL 19/26 75mm 42mm Each Case of 10

GLS071.202.08 * 50mL 14/23 85mm 51mm Each Case of 10

GLS071.202.09 50mL 19/26 85mm 51mm Each Case of 10

GLS071.202.10 50mL 24/29 85mm 64mm Each Case of 10

GLS071.202.11 * 100mL 14/23 105mm 64mm Each Case of 10

GLS071.202.12 100mL 19/26 105mm 64mm Each Case of 10

GLS071.202.13 100mL 24/29 105mm 64mm Each Case of 10

GLS071.202.14 * 100mL 29/32 105mm 64mm Each Case of 10

GLS071.202.15 * 150mL 19/26 118mm 74mm Each Case of 10

GLS071.202.16 * 150mL 24/29 118mm 74mm Each Case of 10

GLS071.202.17 * 150mL 29/32 118mm 74mm Each Case of 10

GLS071.202.18 * 250mL 19/26 140mm 85mm Each Case of 10

GLS071.202.19 * 250mL 24/29 140mm 85mm Each Case of 10

GLS071.202.20 * 250mL 29/32 140mm 85mm Each Case of 10

GLS071.202.22 * 500mL 19/26 175mm 105mm Each Case of 10

GLS071.202.22A * 500mL 24/29 175mm 105mm Each Case of 10

GLS071.202.23 * 500mL 29/32 175mm 105mm Each Case of 10

GLS071.202.25 * 1,000mL 24/29 220mm 131mm Each Case of 10

GLS071.202.26 * 1,000mL 29/32 220mm 131mm Each Case of 10

GLS071.202.27 * 1,000mL 34/35 220mm 131mm Each Case of 10

GLS071.202.28 * 2,000mL 29/32 280mm 166mm Each Case of 6

GLS071.202.29 * 2,000mL 34/35 280mm 166mm Each Case of 6

Kjeldahl Flasks

* denotes products not stocked

Inte

rchan

geab

le G

lass

war

e

74

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Interchangeable Glassware

Stoppers

Glassco Stoppers, Hollow, Flat Bottom

Item Code Socket Size Shape Pack Size Unit

GLS011.202.01 * 10/19 Hexagonal Each Case of 100

GLS011.202.02 * 12/21 Hexagonal Each Case of 100

GLS011.202.02A 14/23 Hexagonal Each Case of 100

GLS011.202.03 19/26 Hexagonal Each Case of 100

GLS011.202.04 24/29 Hexagonal Each Case of 100

GLS011.202.05 29/32 Hexagonal Each Case of 100

GLS011.202.06 34/35 Hexagonal Each Case of 100

* denotes products not stocked

Volu

metric

Glassw

are >>

S

tpp

ers &

Ad

apte

rs

75

Adapters Glassco interchangeable glassware is manufactured from ASTM E-438 Class A BORO 3.3 glass. All joints are first made on semi automatic machines and are then ground with diamond tools for better taper and precision, and then polished to give better finish. All the joints go through strict checks on high vacuum machines for leak check. The different kinds of adapters are then prepared by skilled glassblowers as per the respective standards.

Glassco Reduction Adapters

Item Code Socket Size Cone Size Pack Size Unit

GLS013.202.01 * 14/23 14/23 Each Case of 10

GLS013.202.01A 14/23 19/26 Each Case of 10

GLS013.202.02 14/23 24/29 Each Case of 10

GLS013.202.03 14/23 29/32 Each Case of 10

GLS013.202.04 19/26 24/29 Each Case of 10

GLS013.202.05 19/26 29/32 Each Case of 10

GLS013.202.06 19/26 34/35 Each Case of 10

GLS013.202.07 * 19/26 40/38 Each Case of 10

GLS013.202.08 * 19/26 45/40 Each Case of 10

GLS013.202.09 * 19/26 55/44 Each Case of 10

GLS013.202.10 24/29 29/32 Each Case of 10

GLS013.202.11 24/29 34/35 Each Case of 10

GLS013.202.12 * 24/29 40/38 Each Case of 10

GLS013.202.13 * 24/29 45/40 Each Case of 10

GLS013.202.14 24/29 50/42 Each Case of 10

GLS013.202.15 * 24/29 55/44 Each Case of 10

GLS013.202.16 29/32 34/35 Each Case of 10

GLS013.202.17 * 29/32 40/38 Each Case of 10

GLS013.202.18 * 29/32 45/40 Each Case of 10

GLS013.202.19 * 34/35 40/38 Each Case of 10

GLS013.202.20 * 34/35 45/40 Each Case of 10

GLS013.202.21 * 34/35 50/42 Each Case of 10

Glassco Stoppers, Hollow, Flat Bottom

* denotes products not stocked

Inte

rchan

geab

le G

lass

war

e

76

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Interchangeable Glassware

Glassco Expansion Adapters

Glassco Swan Neck Adapters, with Screw Thread to Accept Thermometers, etc.

Item Code Socket Size Cone Size Pack Size Unit

GLS014.202.01 19/26 14/23 Each Case of 10

GLS014.202.02 24/29 14/23 Each Case of 10

GLS014.202.03 24/29 19/26 Each Case of 10

GLS014.202.03A 29/32 14/23 Each Case of 10

GLS014.202.04 29/32 19/26 Each Case of 10

GLS014.202.05 29/32 24/29 Each Case of 10

GLS014.202.06 * 34/35 19/26 Each Case of 10

GLS014.202.07 * 34/35 24/29 Each Case of 10

GLS014.202.08 * 34/35 29/32 Each Case of 10

GLS014.202.09 * 40/38 24/29 Each Case of 10

GLS014.202.10 * 45/40 29/32 Each Case of 10

Item Code Socket Size Cone Size Pack Size Unit

GLS018.202.01 * 14/23 19/26 Each Each

GLS018.202.01A * 19/26 19/26 Each Each

GLS018.202.02 * 19/26 24/29 Each Each

GLS018.202.03 * 24/29 24/29 Each Each

GLS018.202.04 * 29/32 29/32 Each Each

* denotes products not stocked

Volu

metric

Glassw

are >>

A

dap

ters

77

Glassco Short Stem Adapters

Glassco Long Stem Adapters

Glassco Straight Receiver Adapters

Item Code Socket Size Approx. Length Pack Size Unit

GLS019.202.01 * 14/23 65mm Each Case of 10

GLS019.202.02 * 19/26 65mm Each Case of 10

GLS019.202.03 * 24/29 65mm Each Case of 10

GLS019.202.04 * 29/32 65mm Each Case of 10

Item Code Socket Size Approx. Length Pack Size Unit

GLS019.202.05 * 14/23 190mm Each Case of 10

GLS019.202.06 * 19/26 200mm Each Case of 10

GLS019.202.07 * 24/29 200mm Each Case of 10

GLS019.202.08 * 29/32 200mm Each Case of 10

Item Code Socket Size Pack Size Unit

GLS020.202.01 * 14/23 Each Case of 10

GLS020.202.02 * 19/26 Each Case of 10

GLS020.202.03 * 24/29 Each Case of 10

GLS020.202.04 * 29/32 Each Case of 10

Glassco Expansion Adapters

Glassco Swan Neck Adapters, with Screw Thread to Accept Thermometers, etc.

* denotes products not stocked

Inte

rchan

geab

le G

lass

war

e

78

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Interchangeable Glassware

Glassco Bend Adapters, with Vacuum Connection and Screw Thread Adapter

Glassco Straight Adapters, with Vacuum Connection and Screw Thread Adapter

Glassco Receiver Adapters, with Multiple Connections and Screw Thread

Item Code Socket Size Cone Size Pack Size Unit

GLS022.201.01 * 14/23 14/23 Each Each

GLS022.201.02 * 14/23 19/26 Each Each

GLS022.201.03 * 19/26 19/26 Each Each

GLS022.201.04 * 19/26 24/29 Each Each

GLS022.201.05 * 24/29 24/29 Each Each

GLS022.201.06 * 24/29 29/32 Each Each

GLS022.201.07 * 29/32 29/32 Each Each

Item Code Socket Size Cone Size Pack Size Unit

GLS022.202.01 * 14/23 14/23 Each Each

GLS022.202.02 * 14/23 19/26 Each Each

GLS022.202.02A * 19/26 19/26 Each Each

GLS022.202.03 * 19/26 24/29 Each Each

GLS022.202.04 * 24/29 24/29 Each Each

GLS022.202.05 * 24/29 29/32 Each Each

GLS022.202.06 * 29/32 29/32 Each Each

Item Code Socket Size Cone Size Pack Size Unit

GLS024.202.01 * 14/23 14/23 Each Each

GLS024.202.02 * 14/23 19/26 Each Each

GLS024.202.03 * 19/26 19/26 Each Each

* denotes products not stocked

Volu

metric

Glassw

are >>

A

dap

ters

79

Glassco Plain Bend Receiver Adapters

Glassco Recovery Bends, with Sloping Socket

Item Code Socket Size Cone Size Pack Size Unit

GLS025.202.00 * 14/23 14/23 Each Each

GLS025.202.0A * 14/23 19/26 Each Each

GLS025.202.01 * 19/26 19/26 Each Each

GLS025.202.02 * 19/26 24/29 Each Each

GLS025.202.03 * 24/29 24/29 Each Each

GLS025.202.04 * 29/32 29/32 Each Each

Item Code Cone Size to Fit Flask Cone Size to Fit Condenser Pack Size Unit

GLS026.202.01 * 14/23 14/23 Each Each

GLS026.202.02 * 24/29 14/23 Each Each

GLS026.202.03 * 19/26 19/26 Each Each

GLS026.202.04 * 24/29 19/26 Each Each

GLS026.202.05 * 29/32 19/26 Each Each

GLS026.202.06 * 29/32 29/32 Each Each

GLS026.202.07 * 24/29 24/29 Each Each

GLS026.202.08 * 34/35 24/29 Each Each

GLS026.202.09 * 29/32 24/29 Each Each

GLS026.202.10 * 34/35 34/35 Each Each

Glassco Bend Adapters, with Vacuum Connection and Screw Thread Adapter

Glassco Straight Adapters, with Vacuum Connection and Screw Thread Adapter

Glassco Receiver Adapters, with Multiple Connections and Screw Thread

* denotes products not stocked

Inte

rchan

geab

le G

lass

war

e

80

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Interchangeable Glassware

Glassco Recovery Bends, Vertical

Glassco Splash Heads, Vertical, Pear Shaped

Item Code Cone Size to Fit Flask Cone Size to Fit Condenser Pack Size Unit

GLS027.202.01 * 14/23 14/23 Each Each

GLS027.202.02 * 19/26 19/26 Each Each

GLS027.202.03 * 24/29 24/29 Each Each

GLS027.202.04 * 24/29 24/29 Each Each

GLS027.202.05 * 29/32 29/32 Each Each

Item Code Socket Size Cone Size Pack Size Unit

GLS031.202.01 * 14/23 14/23 Each Each

GLS031.202.02 * 19/26 19/26 Each Each

GLS031.202.03 * 24/29 19/26 Each Each

GLS031.202.04 * 24/29 24/29 Each Each

GLS031.202.05 * 29/32 19/32 Each Each

Glassco Splash Heads, Vertical

Item Code Socket Size Cone Size Pack Size Unit

GLS030.202.01 * 14/23 14/23 Each Each

GLS030.202.02 * 19/26 24/29 Each Each

GLS030.202.03 * 29/32 29/32 Each Each

* denotes products not stocked

Volu

metric

Glassw

are >>

A

dap

ters

81

Glassco Splash Heads, Sloping, Pear Shaped

Item Code Socket Size Cone Size Pack Size Unit

GLS032.202.01 * 14/23 14/23 Each Each

GLS032.202.02 * 19/26 19/26 Each Each

GLS032.202.03 * 24/29 19/26 Each Each

GLS032.202.04 * 24/29 24/29 Each Each

GLS032.202.05 * 29/32 29/32 Each Each

Glassco Adapter Cones, with Stem to Rubber Tubing, Right Angle Connection

Glassco Adapter Sockets to Rubber Tubing, with Screw Thread

Item Code Cone Size Pack Size Unit

GLS036.202.01 14/23 Each Each

GLS036.202.02 19/26 Each Each

GLS036.202.03 24/29 Each Each

GLS036.202.04 * 29/32 Each Each

Item Code Cone Size Pack Size Unit

GLS038.202.01 * 14/23 Each Each

GLS038.202.02 * 19/26 Each Each

GLS038.202.03 * 24/29 Each Each

GLS038.202.04 * 29/32 Each Each

Glassco Recovery Bends, Vertical

Glassco Splash Heads, Vertical, Pear Shaped

Glassco Splash Heads, Vertical

* denotes products not stocked

related products

Inte

rchan

geab

le G

lass

war

e

82

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Interchangeable GlasswareGlassco Socket to Cone Adapters, with Side Arm and Screw Thread

Item Code Socket Size Cone Size Pack Size Unit

GLS039.202.01 * 14/23 14/23 Each Each

GLS039.202.02 * 14/23 19/26 Each Each

GLS039.202.03 * 14/23 24/29 Each Each

GLS039.202.04 * 14/23 29/32 Each Each

GLS039.202.05 * 19/26 19/26 Each Each

GLS039.202.06 * 19/26 24/29 Each Each

GLS039.202.07 * 19/26 29/32 Each Each

GLS039.202.08 * 24/29 24/29 Each Each

GLS039.202.09 * 24/29 29/32 Each Each

GLS039.202.10 * 29/32 29/32 Each Each

* denotes products not stocked

Baskets 84

Drying Racks 84

Pipette Teats 84

Bench Protectors 85

Detergents 85

Water Stills 86

related products

Glassco Socket to Cone Adapters, with Side Arm and Screw Thread

* denotes products not stocked

Rela

ted P

roducts

84

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Related Products

Baskets

Drying Racks

Pipette Teats

Met-App Test Tube Baskets, Autoclavable

Met-App Drying Racks, Autoclavable, White Nylon Coated

LabServ Rubber Teats, for use with Pasteur Pipettes and Glass Droppers

Item Code Type Dimensions (mm) Pack Size Unit

MET4015-150 * White nylon coated 150x150x150 Each Each

MET4015-200 * White nylon coated 200x200x200 Each Each

MET4017-150 * Stainless steel 150x150x150 Each Each

MET4017-200 * Stainless steel 200x200x200 Each Each

Item Code Mount Dimensions (mm) Pack Size Unit

MET4050 Wall mounted 570x600 Each Each

MET4055 * Bench mounted 360x500 Each Each

Item Code Colour Pack Size Unit

LBS444260 Red 10pcs Each

Relate

d P

roducts >>

S

ub

-Sectio

n

85

Met-App Test Tube Baskets, Autoclavable

Met-App Drying Racks, Autoclavable, White Nylon Coated

LabServ Rubber Teats, for use with Pasteur Pipettes and Glass Droppers

Bench ProtectorsBenchkote™ is an absorbent, impermeable material designed to protect laboratory surfaces against hazardous spills. The material features a high-quality, smooth, absorbent Whatman paper which quickly absorbs liquid spills, and a laminated polyethylene layer that prevents flow-through to the working surface. After use the sheet is incinerated or disposed of according to local regulations.

Whatman Benchkote™

Item Code Type Dimensions Pack Size Unit

WHA2300-916 Sheets 460x570mm 50pcs Each

WHA2300-599 * Pad 460x570mm 50pcs Each

WHA2300-731 Reel 460mmx50m Each Each

WHA2300-772 * Reel 920mmx50m Each Each

Detergents

Decon Detergents

Item Code Type Size Pack Size Unit

DEC90-5L Decon 90 liquid concentrate 5L Each Case of 4

DECACIDRINSE * Acid rinse liquid 5L Each Each

DECDECMATIC-5L * Decomatic liquid 5L Case of 4 Case of 4

DECDRI-DECN-5KG Dri-decon granular concentrate 5kg Each Case of 4

* denotes products not stocked

Rela

ted P

roducts

86

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Related Products

Water Stills• The Merit is the ideal choice for budget conscious laboratories that can’t afford to

compromise on quality

• It combines economy and high performance with a host of other features which comparable stills cannot match

• Glass construction with long life metal heating element

• Two independent safety thermostats

• Wall mountable

• Output: 4 litres/hour, single distilled

Stuart Merit Water Still

Labglass Water Stills

Item Code Type Pack Size Unit

BIBW4000 Water Still Merit Each Each

Available in New Zealand Only

Item Code Type Output Feed Pack Size Unit

LABRG1 * Cascade 3L/hr Single Each Each

LABRG2 * Cascade 3L/hr Dual Each Each

LABRG3 * Delta 3-6L/hr Single Each Each

Available in Australia Only

The metal still cases are attractively finished in a durable powder coating. Each still maybe wall, shelf or bench mounted. The still monitors the water level in any reservoir to which you connect it, and controls the operation of the still, turning it on and off as the water level changes in the reservoir. Together with over-temperature and feed water supply failure protection, this allows 24-hour unattended operation of all stills.

technical data

Stuart Merit Water Still

Labglass Water Stills

technical data

Technic

al D

ata

88

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

88

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Technical Data

Glassco NABL Accreditation

Care and Use — Cleaning Methods

Glassco’s Calibration Laboratory has undertaken accreditation for its system for calibration and testing as per ISO 17025:2005. Glassco’s Calibration Laboratory is NABL approved. NABL has an MRA under the Asia Pacific Laboratory Accreditation Cooperation (APLAC) and the International Laboratory Accreditation Cooperation (ILAC), which means the calibration provided to customers for volumetric ware is acceptable in calibration laboratories worldwide.

Care should be exercised when using most cleaning solutions as they can cause skin irritations or severe burns on contact. Dilute solutions become concentrated as the water evaporates; therefore, always flush the exposed area immediately with large quantities of water.

The list of methods given here is by no means complete, but offers a fairly wide variety and should cover all the usual contaminants, as well as the more important special cases.

It is frequently desirable to give glassware a preliminary rinse or soak with an organic solvent to remove grease, followed by a water rinse. The rinsing with water must be done thoroughly if acid will be used later to clean the glassware.

Unless autoclaving is necessary, glassware should be cleaned as soon as possible after use to avoid setting and caking of residues. Pipettes, for example, may be placed in a convenient jar containing a weak antiseptic solution immediately after use. Autoclaving is necessary to disinfect glassware that may have been used to contain potentially dangerous biological fluids.

There is a wide variety of cleaning agents available that will remove surface contaminants such as silicone and other organic and biological residues that may interfere with trace analyses. These cleaners are available in biodegradable, phosphate-free and chromium-free formulations if desired, and can be obtained from Thermo Fisher Scientific.

Results of calibration are guaranteed for precision as per the DIN, ISO, USP & ASTM standards. The calibrations performed by Glassco calibration laboratory are conducted under ISO 17025:2005.

NOTE: If wiping or other mechanical cleaning action is necessary, it should be done gently using non-abrasive cleaners and wiping materials. The use of abrasive materials will damage the glass surface, degrading its inherent strength.

There are some specific contaminants that may require specialised cleaning methods, and some are given here: 1. Permanganate stains. Use a mixture of equal volume of 3% sulfuric acid and 3% hydrogen peroxide.2. Iron stains. Use a solution containing one part hydrochloric acid and one part water.3. Bacteriological material. Glassware should be soaked in a suitable disinfectant solution or steam autoclaved followed by cleaning with a suitable agent.

CAUTIONS: Before using any cleaning solution, refer to its Material Safety Data Sheet for precautions to be observed during use. Some of the cleaning materials used may leave trace residue unless the rinsing process is carried out thoroughly. While such traces may not be harmful if the object of cleaning is to prepare the glassware for calibration, they can give trouble in certain laboratory operations. When glassware is to be calibrated, the final rinsings must be performed with distilled water. If an article is to be dried after cleaning, as is necessary for all vessels marked “To Contain”, ethyl alcohol or acetone (American Chemical Society Specification) may be used. Drying may be hastened by blowing clean, dry air into the vessel (or sucking the air through the vessel). Efficient air filters must be provided to remove any particles.

Technical D

ata >>

Glassw

are

8989

Glassware Safety

Care and Use — Cleanliness of Apparatus

You play by common, ordinary, everyday rules, the kinds of things you’d do naturally if you just took time to think about them:1. Don’t get cut – it hurts you and your productivity.2. Don’t drop glassware – avoid the bruises that lead to breakage.3. Don’t use chipped or broken glassware – it’s dangerous and breaks more readily.4. Don’t mouth pipette – you could inhale a toxic substance, burn your mouth, or cut your lip.5. Don’t leave pipettes sticking out of beakers or flasks – an invitation for an accident.6. Insert tubing carefully. Use a protective towel for your hand and lubricate the tubing.

The usual criterion of cleanliness of glass apparatus is uniform wetting of the surface by distilled water. Certain contaminants, especially grease, adhering to the walls prevent them from being uniformly wetted, and there is a tendency for water to collect into drops.

Imperfect wetting causes irregularities in capacity of volumetric glassware by distorting the meniscus, and also by affecting the volume of the residue adhering to the walls after emptying instruments calibrated to deliver the indicated volume.

Even when the surface of the vessel is uniformly wetted, variations in the apparent capacity still may occur, due to contamination of the liquid surface by minute quantities of fatty or other organic substances which produce a change in surface tension affecting the shape of the meniscus. The cleaning, rinsing and drying, therefore, must be carried out in such a way as to prevent this from happening.

The choice of the procedure to be used in cleaning glassware depends on the nature of the contaminant. In many cases special reagents or methods must be used to remove a particular substance. Before listing the more important methods, it is desirable to make a few general statements.

GlassGlasses used in chemical apparatus have excellent resistance to acids, except hydrofluoric. Strong alkaline solutions, such as hot caustic solutions, will attack any glass if contact is prolonged. This is true even

7. Dispose of broken glassware in a special receptacle.8. Carry large containers carefully, using a bottle carrier.9. Clean and rinse glassware very well with deionised water, then let it drain dry on a clean, lint-free towel.

To back up the rules, you need a formal laboratory safety program. It begins with a written safety policy, a safety committee, and regular safety inspections. That way, you can investigate accidents thoroughly, keep a record and analysis of them, and promote safety awareness all the time. It could lead you to the best safety record ever.

though a particular glass may not exhibit any visible effect, due to the solubility of the reaction products. Dilute detergent solutions, up to about 2% strength, will have no serious effect on the glass, unless the glass is exposed for unnecessarily long periods or the detergent is allowed to dry on the glass.

Coloured GraduationsThe scales and inscriptions of many items of Kimble glassware are coloured by staining a thin layer of the glass. Since the coloured portion is of the same composition as the glass object, the resistance to chemical attack is the same as that of the rest of the glass. Here, the colour can be removed only by dissolving a layer of glass from the surface. Some Kimble volumetric glassware has fused on, ceramic enamel printed lines and inscriptions. These fused-on enamels are quite resistant to acids and alkalies. In most cases they should last as long as the piece of apparatus if cared for properly. However, by their nature, they cannot be as resistant as the ware to which they adhere. Consequently, the graduated lines should not be subjected to prolonged immersion in acids or alkalies. Whenever the lines are wetted by reagents, they should be rinsed as soon as conveniently possible.

Safety PrecautionsWith many pieces of glassware, it is necessary or desirable to fill by suction when cleaning. Do not suck up acid or other cleaners by mouth. In fact, do not pipette by mouth at all. Use hand held, manual or electronic pipetting aids

Technic

al D

ata

90

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

90

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Technical Data

Care and Use — Ground-Glass Surfaces

Recommendations for the Care and Use of Glassware

AbrasivesDo not use abrasives on glassware, particularly volumetric ware. The surface will be marred in time, and the resultant scratches may prevent proper drainage or act as resting places for adulterants which will be difficult to remove.

Water for RinsingWhen preparing a piece of glassware for calibration, rinsing with tap water should be followed by a thorough rinsing with distilled water. Sufficient

Ground-glass joints and stopcocks should never be used when dry. Although ground-glass surfaces seal well without the use of lubricants, it is advisable to lubricate them to prevent sticking and breakage. Ground surfaces must be cleaned prior to lubrication—dust, dirt and particulate

matter may score the surface and cause leakage.Different lubricants are used for these operating conditions:Silicone grease—for high temperature and high vacuumGlycerin—for long term reflux or extractionHydrocarbon grease—for general laboratory use

Lubricating Ground-Glass Joints1. Lubricate joints that must be airtight and when glassware contains

A. TO AVOID SERIOUS AND PERSONAL INJURY, AVOID ABRASIONSAn abrasion reduces the strength of glass, making it more susceptible to breakage under impact and/or thermal shock. Thermal shock may result from sudden changes in temperature or use on either a burner or hot plate. Serious injuries could result if breakage occurs while glass holds heated and/or corrosive liquid.B. RECOMMENDED GLASSWARE CLEANING AND HANDLING PROCEDURESProper Cleaning Procedure1. Washing machines may be used. Support racks on the washer must be well maintained. The support pins should be coated with a nonabrasive material to prevent metal to glass contact and scratching.

material may be deposited on the surface by tap water to cause erratic results, particularly with small items, even though water wets the surface uniformly. Even in ordinary cleaning processes, the use of deionised water is recommended.

Adherent Organic ResiduesNever attempt to remove such residues by the application of direct heat. Permanent strains may be introduced and, what is more important, the calibration of volumetric apparatus may be changed.

strong alkaline solutions.2. Lubricate only the upper part of the inner joint. A properly lubricated joint appears clear, without striations.3. Do not allow grease to come in contact with vapour or liquid and cause contamination.

Lubricating StopcocksSpread two circular bands of grease around the stopcock plug. Insert the plug into the barrel and twist several times until the assembly is completely transparent. Be careful not to use too much lubricant or the bore will become plugged.

2. For manual washing, use only plastic core brushes that have soft nonabrasive bristles. Soft, clean sponges or other wiping materials may be used. DO NOT USE THESE BRUSHES OR WIPING MATERIALS WITH ABRASIVE CLEANERS. Keep them clean. Scotch Brite and similar scouring pads will scratch glass and should not be used.3. Inspect glassware before each use and discard if scratched, chipped, cracked or damaged in any way.4. Many commercial glass cleaners are available. Follow the manufacturer’s directions for the use of these products since some are corrosive and can damage the glass.5. Organic solvents are acceptable cleaning agents when conditions warrant their use.

Technical D

ata >>

Glassw

are

9191

Recommendations for the Care and Use of NMR Tubes

A. TO AVOID SERIOUS AND PERSONAL INJURY, AVOID ABRASIONS AND

IMPACTSAbrasions reduce the strength of glass, making it more susceptible to breakage under impact and/or thermal shock. Thermal shock may result from sudden changes in temperature or use on either a burner or hot plate. Serious injuries could result if breakage occurs while glass holds heated and/or corrosive liquid. Glass will break as a result of impact. Use care when handling to avoid impacting hard objects, such as spigots,

other glassware, counter tops, etc.B. RECOMMENDED GLASSWARE CLEANING AND HANDLING

EQUIPMENT AND PROCEDURESProper Cleaning Procedure1. Kimble Chase offers several styles of NMR tube washers:KON897033-0003 5-place 3mm Tube WasherKON897033-0005 5-place 5mm Tube WasherKON897030-0005 Single-place 5mm Tube WasherKON459960-0000 Single-place 10mm Tube, Cuvette, and Cell Washer2. Before use, rinse or clean the tube with distilled water and dry properly.3. Empty and rinse reusable tubes as soon as possible after use. Always

properly discard disposable NMR tubes as soon as possible after use.4. Use of a fume hood is recommended when cleaning NMR tubes. Popular cleaning solutions include acetone, distilled water, and methanol or ethyl alcohol, as well as organic solvents. Difficult cleaning jobs may require the use of mineral acid or fuming nitric acid soaks. Final rinses of distilled water or acetone are recommended depending on the intended use.5. After cleaning, properly dry by air or with a nitrogen gas stream.6. Inspect tubes before each use and discard if scratched, chipped, cracked or damaged in any way.7. Clean the outside of the tube in order to prevent introduction of dirt or impurities to the probe or the internal mechanisms of the NMR machine.8. Always store NMR tubes in dry, particle free environments. Improper Cleaning Procedure and Use:1. Never use chromic acid, or any caustic or alkaline solutions with an NMR tube.2. Never dry tubes in an oven for more than 30 minutes at 125ºC.3. Never store tubes in an oven. Excessive heat can cause warpage.4. Never use any tube that does not roll evenly on flat surfaces, or exhibits any physical abnormality.

Improper Cleaning Procedure:1. Do not place metal or other hard objects, such as spatulas, glass stirring rods, or brushes with metal parts, inside the glassware. This will scratch the glass and cause eventual breakage and injury.2. Do not use strong alkaline products and hydrofluoric acid as cleaning agents; they are glass dissolvers and can damage the glassware and eventually cause breakage which can result in injury.3. Do not use any abrasive cleansers, including soft cleansers (i.e. Ajax, Comet, Old Dutch, Soft Scrub, etc.), as these will scratch the glass and cause eventual breakage and injury.4. Do not place hands inside glassware while wearing any jewellery, particularly diamond rings, as these will score the inside of the glassware and eventually cause breakage and injury.5. Do not heat glassware to temperatures (>426˚C) needed to burn out carbon residues. This will result in the introduction of permanent stresses in the glass that will eventually cause the glassware to break resulting in

possible injury.C. AVOID IMPACTGlass will break as a result of impact. Use care when handling to avoid impacting hard objects, such as spigots, other glassware, counter tops, etc.

D. HEATING GLASSWARE1. Use wire gauze when heating over open flame.2. Use either low or medium heat settings when using a hot plate. High hot plate settings will cause excessive localised heating of the glassware and will eventually cause breakage and possible injury.3. Do not heat glassware designated as heavy duty unless recommended by the manufacturer. Even though these items have added mechanical strength, they are more susceptible to breakage from thermal shock when heated.4. Do not allow the contents of the container to boil dry as this may induce permanent stresses that will eventually cause breakage. Discard containers that have been boiled dry.DO NOT evacuate or pressurise unless recommended.E. CENTRIFUGE TUBESRCF values can be significantly reduced if the glass tubes have been scratched or otherwise physically abused resulting in surface damage and lowered glass strength.

Technic

al D

ata

92

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

92

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Technical Data

Care and Handling of Volumetric Glassware

“To Contain ” versus “To Deliver”Proper use of calibrated volumetric glassware requires that the user be informed whether the ware is a “to contain” or “to deliver” vessel. All Kimble calibrated ware is marked either “TC” or “TD”. When the graduation line denotes the volume contained in the calibrated vessel, the ware is marked “TC”. When the graduation line indicates the volume delivered from the vessel, the ware is marked “TD”. When a vessel is calibrated “TD”, it differs from a “TC” calibrated vessel in that a drainage holdback error, the amount of water required to wet the inner surface of the vessel in contact with the water, is added to the “TC” volume. The “TD” vessel then delivers the same volume as contained in a “TC” vessel. Product descriptions in this catalog usually state the method of calibration used. (The International Standards Organization designation for “to contain” is “IN” and “to deliver”, is “EX”.)

Pipettes Calibrated “To Deliver” (EX)The pipette is clamped in a vertical position and the 3-way stopcock connected to it with rubber tubing. The bent arm of the stopcock has a length of rubber hose attached which can be held in the mouth or connected to a vacuum line. Distilled water at the temperature of the room is placed in the large beaker. The water is stirred before use, care being taken not to introduce air into it. Before making a weighing, the pipette is filled one or more times from the beaker by applying suction through the stopcock, in order to bring the pipette to the temperature of the water. Finally the pipette is filled to about 10 mm above the mark, the stopcock closed, and the beaker removed.

The stopcock now is opened to connect the pipette to the straight vertical tube and the water lowered slowly to the 0 line. During this emptying, the edge of the tip is kept in contact with the side of the beaker. The rate of descent of the water is controlled by a finger applied to the upper end of this tube. After setting to 0, the stopcock is closed. Then the temperature of the water in the large beaker is taken and this reading is used as the temperature of the water in the pipette. All deliveries should start at the 0 line.

To start the delivery into the receiver the stopcock is opened fully, again connecting pipette and vertical tube. The plug is not touched after this, any control needed being exercised by the forefinger on the vertical tube. The same precautions are taken as for burettes against splashing of water and wetting the upper part of the neck of the receiver.

Where delivery of a measuring or serological pipette is very rapid, the forefinger must be held on the vertical tube from the start of delivery, but water is retarded as little as possible without losing control. For weighings of intermediate lines, water is allowed to empty until a few mm above the line. Then a finger on the vertical tube is used to slow up the delivery so that the water can be set accurately at the mark. The tip is kept in constant contact with the receiving vessel throughout the delivery. Then the receiver is withdrawn and the stopcock closed. When the pipette has an opaque ring or rings near the top, this indicates that the amount of water remaining in the tip after free delivery has ceased is to be blown out and added to the original delivery. A count of two seconds is made after free delivery has ended and while the neck and tip are still in contact, then air is blown through the rubber hose on the bent arm of the stopcock to eject the liquid in the tip. The neck of the bottle is removed from contact immediately after this. Give only one puff, strong enough to expel the liquid. The time of two seconds has been selected as being the average length of time required in actual service after free delivery has ceased to insert the top of the pipette in the mouth preparatory to blowing through.

Pipettes Calibrated “To Contain” (IN)If the capacity is from a mark to the tip, the pipette should be weighed dry, filled with water to the mark and reweighed. To hold the pipette a saddle may be used on the balance pan. The pipette may be set up as explained previously and the filling and setting to the mark accomplished in the same way. Then, a rubber cap or a piece of rubber tubing closed by a short glass rod is slipped up over the tip and the pipette is removed from the stand and weighed. The first weighing of the dry pipette should include the rubber cap or rubber tubing.

When the indicated volume is between marks, the pipette is filled completely up to the top mark, weighed, dried and then filled up to bottom mark and weighed. The difference in weight is the apparent weight of the water contained between the two marks. In this case the weight of the empty pipette is not needed.

Flasks and Cylinders Calibrated “To Contain” (IN)Flasks and cylinders calibrated to contain are cleaned, dried and weighed empty, filled accurately and weighed again. The difference between the two weights, of course, is the apparent weight of the volume contained.

Flasks and Cylinders Calibrated “To Deliver” (EX)If flasks and cylinders calibrated to deliver are to be calibrated, it will be

Technical D

ata >>

Glassw

are

9393

found best to weigh the filled piece first, empty it and weigh again. The second weight includes the film remaining on the walls after delivery. In all cases, the top of the flask or cylinder should be closed by a cap of some type to minimise evaporation losses. Care must also be taken in handling not to deposit moisture or grease from the hands on the surface of the glass. Therefore, the actual contact with the glass should be by means of a clean cloth, gloves or secure holding device. The entire neck of a flask is wetted by the distilled water and a drainage time of about 2 minutes allowed before completing the setting. To fill a cylinder, the water is allowed to run down one side only, although the entire wall is wetted for about 10 mm above the line to be calibrated by rotation or slightly tipping in several directions. A drainage time of about 2 minutes is allowed before the final adjustment is made. For the final adjustment, a pipette or dropper with a finely drawn point should be used. The temperature of the water can be taken in the filled piece just after the weighing has been completed unless the volume is small. In the latter case, if the thermometer happens to be at a different temperature, the reading obtained may be in error due to the effect of the comparatively large bulk of the thermometer in heating or cooling the water. The alternative is to fill the flask from a reservoir and use the temperature of the water in the reservoir. To calibrate centrifuge tubes, Babcock test bottles and similar articles by weighing the water contained, use the methods outlined for flasks and cylinders, except that the wall is wetted above the line being checked only far enough to insure a correctly shaped meniscus.

FILLING AND EMPTYINGThe results obtained with volumetric apparatus depend not only on the accuracy with which the ware is calibrated, but also on the method of use. Insofar as possible, users should manipulate the instruments in exactly the same way as the manufacturer does when locating the calibration lines. The instructions given here apply particularly to apparatus used with a liquid which wets the glass and must be followed in every respect to obtain the most accurate results when such apparatus is to be calibrated. Since mercury does not wet glass, the factors of importance are cleanliness, the use of an ascending meniscus when possible, and the tapping of the vessel before reading the meniscus.

The following rules have been suggested by the National Bureau of Standards. (These requirements may seem at times to be unduly detailed, but they are based on exact knowledge of the behavior of the various types of apparatus as determined experimentally.)

BurettesBurettes should be held in a vertical position and filled to about 10 mm above the 0 line. Any liquid on the outside of the tip is removed at this

time with clean filter paper. The setting to the 0 line is made by slowly emptying the excess liquid into a beaker or other receptacle with the side touching the edge of the tip. Any liquid remaining at the tip after setting has been made is touched-off against the wet side of the receptacle. When delivery is started, stopcocks should be completely open, even though it is necessary to slow the delivery near the end of a titration. If an exact quantity is desired, the liquid is slowed down when it is about 10 mm above the final line in order to set the meniscus accurately at this line. As soon as delivery has been completed the tip is touched to the side of the receiver and the latter removed from contact. Measurements made in laboratories with burettes ordinarily are from the 0 mark. Other initial points may be used on precision apparatus without serious error, but this is not advised with burets having very rapid delivery.

CylindersIn filling a cylinder the liquid is allowed to flow down one side only. However, the entire wall is wetted for about 10 mm above the meniscus, by a gentle rotation of the cylinder or, preferably, by tipping it slightly in several directions. Here, a drainage time of about 2 minutes is allowed before completing the setting. The delivery of the contents of a cylinder is accomplished in the same way as described for a flask.

(NOTE: These directions apply when highly accurate deliveries are wanted. In ordinary laboratory work where measurements are of approximate volumes only, no special precautions in filling and emptying cylinders are necessary.) You should bear in mind, however, that the accuracy you achieve is dependent on your method. Good method, consistently applied, will yield good results. Poor or sloppy methods will yield poor results.

FlasksWhen a solution is made up to a definite strength in a volumetric flask, the entire neck usually is wet at the time the volume is adjusted, due to the mixing process. Consequently, in filling flasks the entire neck is wetted by the distilled water. A drainage time of about 2 minutes is allowed before completing the setting.If a flask is calibrated to deliver its indicated capacity, the delivery is made by gradually inclining the flask, avoiding, as much as possible, agitation of the contents and sloshing around of the liquid. The process should take half a minute. At the end of the emptying the instrument should be nearly vertical and should be held so for another half minute. Then the drop adhering to the lip should be touched off against the wet surface of the receiving vessel.

PipettesPipettes also are held in a vertical position and filled to about 10 mm

Technic

al D

ata

94

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

94

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

Technical Data

above the 0 line. The technique of setting to this line is the same as used for burettes. The rate of outflow at this point is controlled by slight pressure of the forefinger on the top. With MEASURING and SEROLOGICAL PIPETTES, delivery is unrestricted, unless the liquid descends so rapidly that it would be impossible to stop at the desired place. In this case, however, delivery should be as fast as possible while retaining control with a finger. The tip is touched to the side of the receiver when delivery is completed and then removed immediately, except for certain types of serological pipette. These are “calibrated for blowout”, i.e., to deliver the indicated capacity when the small amount remaining in the tip after free delivery has ceased is blown out (with tip in contact with the wet side of the receiver, if possible) and added to the initial volume. As mentioned before, all blowout pipettes are marked with either a wide opaque ring, two narrower opaque rings near the top, or two printed rings near the top.

(NOTE: With measuring pipettes of small capacity, there may be a tendency for free delivery to cease before the liquid reaches the lowest graduation lines. If this is so, the tip should be kept in contact with the receiving vessel during the delivery, and not just to touch off the last drop when delivery is finished.)

VOLUMETRIC PIPETTES are held in a vertical position and outflow is unrestricted. The tip is touched to the wet surface of the receiving vessel and kept in contact with it until the water has ceased to flow. A count of two is made and the tip then withdrawn horizontally from contact with the receiver. The water remaining in the tip is not blown out, except in the case of Ostwald pipette used in biochemical work. These pipettes are usually “calibrated for blowout” and are marked also with an opaque ring near the top.

Physical Properties of Glass

Glass is an inorganic product of fusion that has cooled to a rigid condition without crystallising and, therefore, has no melting point as such. There are, however, four temperatures that are of interest to the glassblower. They are:

1. The Working Point — the temperature at which glass has a viscosity of 104 poises. At this temperature, glass is soft enough for most lampworking or sealing operations.

2. The Softening Point — the temperature at which glass has a viscosity of 107.6 poises. In this temperature range glass will deform noticeably under its own weight: ASTM C 338.

3. The Annealing Point — the temperature at which the internal stress caused by rapid cooling from lampworking or forming temperatures may be substantially removed in a matter of minutes. It is determined by measuring the elongation rate versus temperature of a fiber of glass under conditions prescribed by ASTM Designation C 336. The values given herein are typical for production glasses.

4. The Strain Point — the temperature at which the internal strain in a glass is substantially relieved only after a matter of hours and not at a commercially desirable rate. It is determined by extrapolation of annealing point data for fiber elongation: ASTM C 336.

Technical D

ata >>

Glassw

are

9595

Table 2

Physical Properties of KG-33 and N-51A Glasses

KG-33 N-51A

Working Point 1255°C 1140°C

Strain Point 513°C 530°C

Annealing Point 565°C 570°C

Softening Point 827°C 785°C

Linear Coefficient of Expansion (from 0 to 300°C), in./in./°C 32x10-7 55x10-7

Density grams per cm3 2.22 2.33

Refractive Index—Sodium D line (.5893 microns) 1.47 1.49

Visible Light Transmission, 2 mm thickness 92% 91%

Specific Heat (in g. cals per g. deg.) 0.204 0.204

(25 to 175°C) (25 to 175°C)

Thermal Conductivity (in cals/cm/cm2/sec/°C) 0.0027 0.0026

Technic

al D

ata

96

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Technical Data

Ground Ware

is the symbol used to designate “standard taper” interchangeable joints, stoppers and stopcocks, complying with the requirements of ASTM E675 for stopcocks, stoppers and reagent bottle necks and E676 for interchangeable joints. All mating parts are finished to a 1:10 taper.

The size of a particular piece appears after the appropriate symbol. Due primarily to the greater variety of apparatus equipped with fittings, a number of different types of identifications are used, as follows: Apparatus and Bottles• For joints - a two part number, as 24/40, with 24 being the

approximate diameter in mm at the large end of the taper, and 40 the axial length of taper, also in mm.

• For bottles - a single number, as 19, with 19 being the approximate diameter in mm of the opening at top of neck.

• For glass stopcocks - a single number, as 2, with 2 being the approximate diameter in mm of the bore or bores through the plug.

Flasks• For volumetric and Erlenmeyer flasks, graduated cylinders, etc.

a single number as 19, with 19 again being the approximate diameter in mm at top of neck; however, there are differences in dimensions between the bottle and flask stoppers, see the individuals listings in this catalogue.

is the designation for “spherical (semi-ball) joints” complying with ASTM E677.

The complete designation of a spherical joint also consists of a two part number, as 12/2, with 12 being the approximate diameter in mm of the ball and 2 the bore in mm of the ball and the socket.

is the symbol used to designate “product standard” compliance. Kimble glass stop cocks with plugs made of PTFE meet the requirements of ASTM Specification E911. The symbol is used to designate that Kimble stopcocks comply with this standard. All mating parts are finished to a 1:5 taper.

Finally, for the PTFE plug ware, a single number is used, as with stopcocks. Thus, 2 means a stopcock with a bore of approximately 2 mm in the plug.

Standard Taper Symbol Spherical Joint Symbol

Product Standard Symbol

Technical D

ata >>

Gro

und

Ware

97

Technic

al D

ata

98

Labo

rato

ry G

lass

war

e C

atal

ogue

201

2/13

* denotes products not stocked

Technical Data

Ground Ware

Standard Dimensions for Full-length InterchangeableTaper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

7/25............. 5 25 7.5 10/30............ 7 30 10.0 12/30.......... 9.5 30 12.5 14/35............ 11 35 14.5 19/38............ 15 38 18.8

24/40............ 20 40 24.0 29/42............ 25 42 29.2 34/45............ 30 45 34.5 40/50............ 35 50 40.0 45/50............ 40 50 45.0

50/50............ 45 50 50.0 55/50............ 50 50 55.0 60/50............ 55 50 60.0 71/60............ 65 60 71.0103/60 ........... 97 60 103.0

Standard Dimensions for Short-length InterchangeableTaper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

5/8............. 4.2 8 5.0 7/10............ 6.5 10 7.510/7 ............ 9.3 7 10.0

10/10 ........... 9.0 10 10.012/10 ...........11.5 10 12.514/10 ...........13.5 10 14.5

19/10 ...........17.8 10 18.824/12 ...........22.8 12 24.029/12 ...........28.0 12 29.234/12 ...........33.3 12 34.540/12 ...........38.8 12 40.0

45/12 ...........43.8 12 45.050/12 ...........48.8 12 50.055/12 ...........53.8 12 55.060/12 ...........58.8 12 60.071/15 ...........69.5 15 71.0

Standard Dimensions for Medium-lengthInterchangeable Taper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

5/12................ 3.8 12 5.07/15................ 6.0 15 7.5

10/18................ 8.2 18 10.012/18...............10.7 18 12.514/20...............12.5 20 14.5

19/22...............16.6 22 18.824/25...............21.5 25 24.029/26...............26.6 26 29.234/28...............31.7 28 34.540/35...............36.5 35 40.0

Standard Dimensions for InterchangeableSpherical-Ground Joints

Standard NominalJoint Size Nominal Tube Gauging BallNumber Diameter Diameter Diameter

( Designation) mm I.D. mm inches

7/1 ................. 7 1 .28125 ± .00005 12/1 ............... 12 1 .5000 ± .0001 12/1.5 ............ 12 1.5 .5000 ± .0001 12/2 ............... 12 2 .5000 ± .0001 12/3 ............... 12 3 .5000 ± .0001 12/5 ............... 12 5 .5000 ± .0001

18/7 ............... 18 7 .7500 ± .0001 18/9 ............... 18 9 .7500 ± .0001 28/12 ............. 28 12 1.1250 ± .00015 28/15 ............. 28 15 1.1250 ± .00015 35/20 ............. 35 20 1.3750 ± .00015

35/25 ............. 35 25 1.3750 ± .00015 40/25 ............. 40 25 1.6500 ± .00015 50/30 ............. 50 30 2.0000 ± .00015 65/40 ............. 65 40 2.5000 ± .0002 75/50 ............. 75 50 3.0000 ± .00025102/75 ...........102 75 4.0000 ± .0003

Standard Dimensions for Full-length InterchangeableTaper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

7/25............. 5 25 7.5 10/30............ 7 30 10.0 12/30.......... 9.5 30 12.5 14/35............ 11 35 14.5 19/38............ 15 38 18.8

24/40............ 20 40 24.0 29/42............ 25 42 29.2 34/45............ 30 45 34.5 40/50............ 35 50 40.0 45/50............ 40 50 45.0

50/50............ 45 50 50.0 55/50............ 50 50 55.0 60/50............ 55 50 60.0 71/60............ 65 60 71.0103/60 ........... 97 60 103.0

Standard Dimensions for Short-length InterchangeableTaper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

5/8............. 4.2 8 5.0 7/10............ 6.5 10 7.510/7 ............ 9.3 7 10.0

10/10 ........... 9.0 10 10.012/10 ...........11.5 10 12.514/10 ...........13.5 10 14.5

19/10 ...........17.8 10 18.824/12 ...........22.8 12 24.029/12 ...........28.0 12 29.234/12 ...........33.3 12 34.540/12 ...........38.8 12 40.0

45/12 ...........43.8 12 45.050/12 ...........48.8 12 50.055/12 ...........53.8 12 55.060/12 ...........58.8 12 60.071/15 ...........69.5 15 71.0

Standard Dimensions for Medium-lengthInterchangeable Taper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

5/12................ 3.8 12 5.07/15................ 6.0 15 7.5

10/18................ 8.2 18 10.012/18...............10.7 18 12.514/20...............12.5 20 14.5

19/22...............16.6 22 18.824/25...............21.5 25 24.029/26...............26.6 26 29.234/28...............31.7 28 34.540/35...............36.5 35 40.0

Standard Dimensions for InterchangeableSpherical-Ground Joints

Standard NominalJoint Size Nominal Tube Gauging BallNumber Diameter Diameter Diameter

( Designation) mm I.D. mm inches

7/1 ................. 7 1 .28125 ± .00005 12/1 ............... 12 1 .5000 ± .0001 12/1.5 ............ 12 1.5 .5000 ± .0001 12/2 ............... 12 2 .5000 ± .0001 12/3 ............... 12 3 .5000 ± .0001 12/5 ............... 12 5 .5000 ± .0001

18/7 ............... 18 7 .7500 ± .0001 18/9 ............... 18 9 .7500 ± .0001 28/12 ............. 28 12 1.1250 ± .00015 28/15 ............. 28 15 1.1250 ± .00015 35/20 ............. 35 20 1.3750 ± .00015

35/25 ............. 35 25 1.3750 ± .00015 40/25 ............. 40 25 1.6500 ± .00015 50/30 ............. 50 30 2.0000 ± .00015 65/40 ............. 65 40 2.5000 ± .0002 75/50 ............. 75 50 3.0000 ± .00025102/75 ...........102 75 4.0000 ± .0003

Technical D

ata >>

Gro

und

Ware

99

Standard Dimensions for Full-length InterchangeableTaper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

7/25............. 5 25 7.5 10/30............ 7 30 10.0 12/30.......... 9.5 30 12.5 14/35............ 11 35 14.5 19/38............ 15 38 18.8

24/40............ 20 40 24.0 29/42............ 25 42 29.2 34/45............ 30 45 34.5 40/50............ 35 50 40.0 45/50............ 40 50 45.0

50/50............ 45 50 50.0 55/50............ 50 50 55.0 60/50............ 55 50 60.0 71/60............ 65 60 71.0103/60 ........... 97 60 103.0

Standard Dimensions for Short-length InterchangeableTaper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

5/8............. 4.2 8 5.0 7/10............ 6.5 10 7.510/7 ............ 9.3 7 10.0

10/10 ........... 9.0 10 10.012/10 ...........11.5 10 12.514/10 ...........13.5 10 14.5

19/10 ...........17.8 10 18.824/12 ...........22.8 12 24.029/12 ...........28.0 12 29.234/12 ...........33.3 12 34.540/12 ...........38.8 12 40.0

45/12 ...........43.8 12 45.050/12 ...........48.8 12 50.055/12 ...........53.8 12 55.060/12 ...........58.8 12 60.071/15 ...........69.5 15 71.0

Standard Dimensions for Medium-lengthInterchangeable Taper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

5/12................ 3.8 12 5.07/15................ 6.0 15 7.5

10/18................ 8.2 18 10.012/18...............10.7 18 12.514/20...............12.5 20 14.5

19/22...............16.6 22 18.824/25...............21.5 25 24.029/26...............26.6 26 29.234/28...............31.7 28 34.540/35...............36.5 35 40.0

Standard Dimensions for InterchangeableSpherical-Ground Joints

Standard NominalJoint Size Nominal Tube Gauging BallNumber Diameter Diameter Diameter

( Designation) mm I.D. mm inches

7/1 ................. 7 1 .28125 ± .00005 12/1 ............... 12 1 .5000 ± .0001 12/1.5 ............ 12 1.5 .5000 ± .0001 12/2 ............... 12 2 .5000 ± .0001 12/3 ............... 12 3 .5000 ± .0001 12/5 ............... 12 5 .5000 ± .0001

18/7 ............... 18 7 .7500 ± .0001 18/9 ............... 18 9 .7500 ± .0001 28/12 ............. 28 12 1.1250 ± .00015 28/15 ............. 28 15 1.1250 ± .00015 35/20 ............. 35 20 1.3750 ± .00015

35/25 ............. 35 25 1.3750 ± .00015 40/25 ............. 40 25 1.6500 ± .00015 50/30 ............. 50 30 2.0000 ± .00015 65/40 ............. 65 40 2.5000 ± .0002 75/50 ............. 75 50 3.0000 ± .00025102/75 ...........102 75 4.0000 ± .0003

Standard Dimensions for Full-length InterchangeableTaper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

7/25............. 5 25 7.5 10/30............ 7 30 10.0 12/30.......... 9.5 30 12.5 14/35............ 11 35 14.5 19/38............ 15 38 18.8

24/40............ 20 40 24.0 29/42............ 25 42 29.2 34/45............ 30 45 34.5 40/50............ 35 50 40.0 45/50............ 40 50 45.0

50/50............ 45 50 50.0 55/50............ 50 50 55.0 60/50............ 55 50 60.0 71/60............ 65 60 71.0103/60 ........... 97 60 103.0

Standard Dimensions for Short-length InterchangeableTaper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

5/8............. 4.2 8 5.0 7/10............ 6.5 10 7.510/7 ............ 9.3 7 10.0

10/10 ........... 9.0 10 10.012/10 ...........11.5 10 12.514/10 ...........13.5 10 14.5

19/10 ...........17.8 10 18.824/12 ...........22.8 12 24.029/12 ...........28.0 12 29.234/12 ...........33.3 12 34.540/12 ...........38.8 12 40.0

45/12 ...........43.8 12 45.050/12 ...........48.8 12 50.055/12 ...........53.8 12 55.060/12 ...........58.8 12 60.071/15 ...........69.5 15 71.0

Standard Dimensions for Medium-lengthInterchangeable Taper-Ground Joints

ComputedDiameter at

Standard Approximate Approximate Large End ofJoint Size Diameter at Length of Ground ZoneNumber Small End Ground Zone (Gauging Point)

( Designation) mm mm mm

5/12................ 3.8 12 5.07/15................ 6.0 15 7.5

10/18................ 8.2 18 10.012/18...............10.7 18 12.514/20...............12.5 20 14.5

19/22...............16.6 22 18.824/25...............21.5 25 24.029/26...............26.6 26 29.234/28...............31.7 28 34.540/35...............36.5 35 40.0

Standard Dimensions for InterchangeableSpherical-Ground Joints

Standard NominalJoint Size Nominal Tube Gauging BallNumber Diameter Diameter Diameter

( Designation) mm I.D. mm inches

7/1 ................. 7 1 .28125 ± .00005 12/1 ............... 12 1 .5000 ± .0001 12/1.5 ............ 12 1.5 .5000 ± .0001 12/2 ............... 12 2 .5000 ± .0001 12/3 ............... 12 3 .5000 ± .0001 12/5 ............... 12 5 .5000 ± .0001

18/7 ............... 18 7 .7500 ± .0001 18/9 ............... 18 9 .7500 ± .0001 28/12 ............. 28 12 1.1250 ± .00015 28/15 ............. 28 15 1.1250 ± .00015 35/20 ............. 35 20 1.3750 ± .00015

35/25 ............. 35 25 1.3750 ± .00015 40/25 ............. 40 25 1.6500 ± .00015 50/30 ............. 50 30 2.0000 ± .00015 65/40 ............. 65 40 2.5000 ± .0002 75/50 ............. 75 50 3.0000 ± .00025102/75 ...........102 75 4.0000 ± .0003

1338168170-01-0512-GRP©2012 Thermo Fisher Scientific Inc. All rights reserved.

Australia: For customer service, call 1300-735-292 Visit us online at: www.thermofisher.com.auNew Zealand: For customer service, call 0800-933-966 Visit us online at: www.thermofisher.co.nz

© 2012 Thermo Fisher Scientific Inc. All rights reserved. Specifications, terms & pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

Thermo Fisher Scientific is committed to working with you to increase

efficiency, giving you the freedom to focus on your research. Our goal is

to help you succeed. However you measure success, we can provide the

resources and the programs to help you achieve it. By choosing Thermo

Fisher, you have selected a partner with over a century of experience.