CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... ·...

104

Transcript of CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... ·...

Page 1: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a
Page 2: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

201

No matter how large your premises and whatever your air conditioning needs, there is a Daikin chilled water system to suit your requirements. It is a system that has proved its worth in a multiplicity of situations - from industrial sites to retail warehouses, hotels and department stores.

The careful development of closely matched compressor/refrigerant combinations, has enabled Daikin to produce complete ranges of water chillers — genuinely optimised for use with R-134a, R-407C and R-410A refrigerants.

Daikin chillers offer the ultimate in flexibility and control — a reflection of the advanced technology inherent within them. Unique in their precision, power, low operating noise, easy maintenance and low running costs, Daikin chillers represent the sure and safe route to an indoor environment that is comfortable, clean and consistent.

As a manufacturer that makes its own refrigerant and compressors, Daikin has total control at the production stage. Daikin also offers a complete range of air handling units to meet modern day requirements for better indoor air quality and increased insulation standards.

It is this unique combination of advanced technology, experience and reliability that makes Daikin the obvious choice and long term solution for the professional.

CHILLERSAir-Cooled 206

EWAQ-ACV3 206EWYQ-ACV3 207EWAQ-ACW1 208EWYQ-ACW1 209EUWAC-FZW 210EUWA*-KAZW 212EUWY*-KAZW 213EWAQ-DAYN 214EWYQ-DAYN 215EWAD-MBYN 216EWAD-AJYNN 217EWAD-AJYNN/A 218EWAD-AJYNN/Q 219EWAD-AJYNN/H 220EWAD-AJYNN/S 221EWAD-AJYNN/X 222EWYD-BZSS 224EWYD-BZSL 225EWAD-C-SS/SL 226EWAD-C-SR 227EWAD-C-XS/XL 228EWAD-C-XR 229EWAD-C-PS/PL 230EWAD-C-PR 231

Water-Cooled 232

EWWP-KAW1N 233EWWD-MBYN 234EWWD-DJYNN 235EWWD-DJYNN/A 236EWWD-EJYNN 237EWWD-EJYNN/A 238EWWD-BJYNN 239EWWQ-AJYNN 240EWWQ-AJYNN/A 241

Condenserless Chiller 242

EWLP-KAW1N 242EWLD-MBYN 243EWLD-DJYNN 244EWLD-EJYNN 245

Centrifugal Chiller 246

DWSC, DWDC 246

DICN (Daikin Integrated Chiller Network) 248EHMC (Hydraulic Module) 249EKBT (Buff er Tank) 249

For more information on Options & Accessories, please refer to page 296 of this catalogue.

�������������

NEW

NEW*

NEW

NEW

NEW

NEW

NEW

NEW

NEW*

NEW

NEW

NEW

NEW

NEW

NEW

Page 3: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

APPLIED SYSTEMS PORTFOLIO

23

0

25

4

20

9

32

9

35

8

39

5

42

3

330

360

400

420

2222

32

9

35

8

39

5

42

3

330

360

400

420

2222

80

10

5

15

2

18

2

13

1

2 2 2 2 21 1 2

080

100

130

150

180

210

240

260

18

,4

11

,6

23

,8

5 8 10

1 1 1

12

1

14

9

17

1

22

6

28

6

33

0

37

2

150

170

240

300

340

380

120

1 1 1 2 2 2 2

18

4

19

8

22

5

24

5

26

1

27

5

29

8

32

1

37

0

40

1

190

200

230

260

280

300

320

340

360

400

2222222222

24

7

27

5

30

1

32

7

35

1

37

6

40

1

260

280

320

340

360

380

420

2 2 2 2 2 2 2

19

5

20

8

23

3

25

6

27

4

28

9

30

6

33

6

38

1

42

6

200

210

240

260

280

300

320

340

400

222222222

20

3

23

1

25

3

27

1

28

62

99

30

9

40

0

240

210

260

280

300

320

340

400

2 2 2 2 2 2 2 2

509,1

17,1

21 25 34 403

7

46

54

27

24

18

12

5 8 10 12 16

20

24

2221111

1 1 1 1 2 2 2

11,3

18 22,5

26,5

37 46,6

55,3

8 10 12 16 20 245

1 1 1 1 2 2 2

2 2 2 21 1 2 2

2 2 2 2 2 21 1

080

100

130

150

180

210

230

16

5

19

9

22

5

25

8

88

11

4

28

4

149

250

77

145

18

3

23

4

25

2

10

0

136

21

1

324

324

349

297

297

349

379

379

410

410

270

270

333

333

250

250

270

270

290

290

320

320

340

330

370

360

380

370

410

400

430

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2 2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

25

424

8

27

326

6

29

229

1

32

431

6

33

933

1

36

535

5

38

237

2

41

340

3

425

7,1

11

5,2

6

005

006

007

011

1 1 1

8,5

009

1

9,5

010

1 1

13

013

1

900

9

1

011

1

11

5,6

5

7,7

5

10

11

,5

13

14

6,3

5

1

1

1

12

,5

1

1 1 1 1 1

7,1

11

5,2

6

005

006

007

011

1 1 1

8,5

009

1

9,5

010

1 1

13

013

1

900

9

1

11

011

1

Type Compr. Refr. Mode Reference Packshot 0 17.5 200

A/C

SWING R-410A s EWAQ005-007ACV3EWAQ009-011ACV3

SCROLL R-410AEWAQ009-013ACW1

SWING R-410A EWYQ005-007ACV3EWYQ009-011ACV3

SCROLL R-410AEWYQ009-013ACW1

SCROLL

R-407C

EUWAC5-10FZW

EUWA*5-24KAZW

EUWY*5-24KAZW

R-410A

EWAQ080-260DAYN

EWYQ080-250DAYN

SCREW R-134a

EWAD120-600MBYNN

EWAD190-600AJYNN

EWAD260-650AJYNN/A

EWAD210-500AJYNN/Q

EWAD200-600AJYNN/H

EWAD330-550AJYNN/S

EWAD330-550AJYNN/X

EWYD250-580BZSS

EWYD250-570BZSL

EWAD650-C17C-SS/SL

EWAD620-C16C-SR

EWAD760-C19C-XS/XL

EWAD740-C19C-XR

EWAD820-C14C-PS/PL

EWAD810-C14C-PR

202

, 4

0 5566 3 441 2

33331

301

3

1

37

638

0

3716

2

80

080

23

0

2

240

1

2

297

22

333

3

2

379

338

03

2

2

38

297

2

333

33033

2

2

331

379

37037

02

372

4, 44343

7

1788

1

0 5566 3 1 444411 2

149

2

1021

99

21

29

832

0

98

23

124

0

2

27

128

0

2

99

23

324

0

2

27

428

0

2

30

632

0

2

38

140

0

2

54

5 7 99

42 3 66 88

22 11 55 55

63

56

3

77

57

1

10

33333331

2,5

13

1303

55

1

Page 4: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Portfolio Air-Cooled Units

42

3

51

5

45

9

48

8

420

460

490

520

2222

42

3

51

5

45

9

48

8

420

460

490

520

2222

44

9

52

5

60

5

460

520

600

2 2 2

51

0

55

1

58

8

45

1

47

8

440

480

500

550

600

22222

50

1

53

1

58

2

62

7

500

550

600

650

2 2 2 2

50

2

42

6

46

8

52

9

60

0

56

1

420

460

480

500

550

600

222222

42

8

44

8

50

1

440

460

500

2 2 2

443

443

463

463

475

475

530

530

558

558

615

615

440

460

450

510

490

520

510

580

570

2 3

3

3

3

3

3

3

3

2

2

2

2

3

3

3

3

3

3

3

3

43

6

45

744

8

50

549

3

52

251

0

58

356

7

75

6

83

0

88

9

12

80

10

01

11

96

10

74

13

49

15

96

15

26

14

09

16

85

17

68

18

58

760

830

890

990

C10

C11

C12

C13

C14

C15

C16

C17

C18

C19

22222 3 3 3333222

73

6

82

1

80

98

11

89

0

87

58

66

97

59

56

12

47

13

90

13

59

13

02

13

78

14

86

15

50

16

39

17

22

18

13

97

4

10

74

10

53

10

41

11

58

11

32

11

68

12

79

12

51

740

820

810

810

890

880

870

980

960

970

C11

C10

C10

C12

C11

C11

C13

C13

C12

C14

C14

C13

C14

C15

C16

C17

C18

C19

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2 3 3 3 3 3 3

64

7

74

4

83

2

11

53

96

7

91

2

16

22

10

64

14

19

15

38

17

14

650

740

830

910

970

C11

C12

C14

C15

C16

C17

2 2 2 2 2 2 2 3 3 3 3

61

9

71

5

78

9

13

67

87

6

11

12

10

20

14

71

16

23

15

56

620

720

790

880

C10

C11

C13

C14

C15

C16

2 2 2 2 2 2 2 3 3 3

A/C = Air Cooled

W/C = Water Cooled

C/C = Condenserless Chiller

= Cooling Only

= Heating Only

= Heat Pump

= Heating

= Cooling

/A High Efficiency Unit

/Q Standard Efficiency Unit, Extra Low Noise

/H High Ambient Unit

/S Standard Seasonal Efficiency Inverter Unit

/X High Seasonal Efficiency Inverter Unit

500 1,000 2,000

203

kW

45

946

0

2

45

946

0

2

746

04

0

3

45

558

3

615

48

849

0

2

48

849

0

2

558

3

615

61

962

0

2

13

67

C13

2

16

23

C16

3

11

96

C11

2

88

C

10

53

C10

2

13

59

13

59

C14

C14

2

9049

3

493

10

01

990

60

560

0

55

155

0

2

44

846

0

2

3 55 000 222 88

10

64

C11

2

16

22

C16

3

17

14

C17

96

797

0

2

13

78

C14

18

13

C19

89

0

Page 5: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Type Compr. Refr. Mode Reference Packshot 0 17.5 200

W/C

SCROLL R-407CEWWP014-065KAW1N

EWWP090-195KAW1

SCREW

R-134a

EWWD120-540MBYNN

EWWD170-600DJYNN

EWWD190-650DJYNN/A

EWWD340-C18EJYNN

EWWD360-C12EJYNN/A

EWWD380-C11BJYNN

R-410A

EWWQ400-C20AJYNN

EWWQ440-C22AJYNN/A

CENTRI-FUGAL

R-134a

DWSC

DWDC

C/C

SCROLL R-407C EWLP012-65KAW1N

SCREW R-134a

EWLD120-540MBYNN

EWLD160-550DJYNN

EWLD320-C17EJYNN

APPLIED SYSTEMS PORTFOLIO

1

300

420

42

8

2

400

38

1

2

360

35

2

2

320

31

5

2

270

27

0

1

240

24

4

1

190

18

9

1

160

16

0

1

2712,1

20 5431 40 62

012

020

026

030

045

055

065

1 1 1 1 2 2 2

120

170

240

260

340

400

480

17

0

11

6

23

5

34

0

26

5

40

5

47

0

2221111

43

344

0

1

36

236

0

1

36

9

44

5

380

460

11

46

0

33

3

39

4

340

400

460

1 1 1

38

840

0

1

43

144

0

1

15,4

35 41 52 71 8126 105

124

142

153

164

176

213

224

235

246

19501

4

022

028

035

045

055

065

090

110

120

130

145

155

165

175

185

195

100

8613 21 28 32 43 56 65 195

99 112

121

130

142

155

168

177

186

222222222222211 211

1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2

18

3

12

3

27

3

24

9

43

2

36

6

120

180

240

280

360

440

14

7

21

6

29

0

32

7

43

1

1 1 1 1 2 2

1 1 1 1 2

16

5

20

1

25

3

28

0

37

2

40

2

44

8

170

210

260

300

320

380

420

460

1 1 1 1 2 2 2 2

18

6

22

3

27

6

30

7

36

6

40

8

44

4

190 230

280

320

380

400

460

2221111

226

1

271

1

336

1

378

1

446

2

208

252

318

356

418

465

1 1 1 1 2 2

420

42

8

1

400

39

1

1

320

32

8

1

66 33 66 77 66 88 44

8 22 0000 22 5555 88 77 5577 66

e

2002

0

6206

5

2

4004

5

2

240

23

5

1

270

27

0

400

38

1

2

420

42

8

88855 1 000

7

22 22 88

418

884

4466

0

2

27

8020

1

33

154

1

65065

2

9000

86

2

105

2

301313

2

55115

15

1767

75117

2

2131

2 3

22 8 74 7 6 3

35035

32

420

42

8

666 33 776666 77 66 8888 4444

271

1

30

378

1

300

204

Page 6: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

500 1,000 2,000 9,000

Portfolio Water-Cooled Units

A/C = Air Cooled

W/C = Water Cooled

C/C = Condenserless Chiller

= Cooling Only

= Heating Only

= Heat Pump

= Heat Recovery

= Heating

= Cooling

kW

1

4500

2 2

600

9000

550

52

5

2

480

47

5

2

480

500

540

50

0

47

0

53

0

222

11

34

C12

2

10

38

C11

2

93

395

0

2

97

6C1

0

2

86

685

0

2

79

580

0

2

72

075

0

2

57

360

0

1

50

650

0

1

52

1

73

4

81

6

89

5

97

6

10

50

550

750

850

900

C10

C11

111111

60

70

5

64

0

53

8

78

2

550

650

700

800

11

55

3

C12

12

04

3

C13

12

74

3

C14

13

46

3

C15

14

01

3

C16

14

55

3

C17

15

10

3

C18

1 2 2 2

84

485

0

2

91

090

0

2

10

27

C10

2

98

695

0

2

47

4

74

2

65

1

57

4

88

0

81

3

10

77

10

28

89

1

98

0

12

10

14

88

13

52

12

81

16

20

17

83

19

28

20

93

2 2 2 2 1 2 2 2 2

480

600

650

750

800

850

900

C10

C11

C12

C13

C14

C15

C16

C17

C18

C19

C20

1 1 1 1 2 1 2 2 1

52

7

81

8

74

0

65

3

99

3

11

39

11

82

13

97

12

97

14

79

16

05

17

69

19

01

20

61

21

96

1 2 2 2 2 1 2 2 2 2

550

650

750

800

950

C10

C11

C12

C13

C14

C15

C16

C18

C19

C20

C22

1 1 1 1 1 2

52

2

49

8

54

6

500

520

540

50

5

58

0

61

7

65

5

2 2 2

22 2 2

49

4

55

6

500

600

2 2

49

6

60

4

54

0

500

550

650

222

741

2

495

2

539

2

601

2

655

2

504

563

623

705

22 2 2

C17

14

22

3

C16

13

70

3

C15

13

19

3

C14

12

67

3

C13

11

88

3

C12

11

25

3

800

78

8

2

850

85

0

2

900

91

9

2

950

96

6

2

C11

10

78

3

C10

10

03

3

750

73

0

2

650

65

7

2

600

59

6

2

500

50

4

1

66 00 444

005

00

49

0050

44 66

6

88

085

0

1

98

0

13

52

C15

20

93

20

93

2

C20

C20

54

6665

55

5006060

0

2

61

77

66

12

10

C13

89 29 44

6

850

85

0

2

C10

10

03

3

C15

13

19

3

50

650

0

86

6

93

395

0

2

6666 000066 4444

49

60050

0955

12

04

3

C13

99

395

0

1

20

61

C20

2

600

600

1

4500

4500

9,0

205

Page 7: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Mini-Chiller

› Optimised for use with R-410A.

› Inverter controlled swing compressor

› Inverter controlled scroll compressor

› ESEER up to 4.57

› Sound operation down to 62dBA

› PE treated condenser coil

› Built-in hydraulic module

› Adaptive control possibility

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWEERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Type Brazed plate

Water volume lMinimum water volume in the system lWater flow rate Min l/minNominal Water Flow Cooling l/min

Air heat exchanger Type Tube type Hi-XSSExternal static pressure Cooling kPaExpansion vessel Volume lCompressor Type Hermetically sealed swing compressor Inverter hermetically sealed scroll compressor

Model QuantitySound Power Cooling dBASound Pressure Cooling Rated dBA

Night quiet dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Inverter Electronic expansion valve

Power Supply 1~/230V/50HzPiping connections Water heat exchanger inlet, outlet / drain 1'' mbsp / hose nipple 1/2'' fbsp -

Piping / Diameter Inch - 3 / G 5/4/"

BRC1D52

005 006 007 009 010 011

5.2 6.0 7.1 8.5 9.5 11.01.89 2.35 2.95 2.74 3.19 3.822.75 2.55 2.41 3.11 2.98 2.883.75 3.83 3.87 4.57 4.52 4.46

805x1,190x360 1,435x1,418x382100 180104 -

- 1.0110 -12 16

14.9 17.2 20.4 24.4 27.2 31.5

49.4 45.1 38.3 60.2 57.5 53.06 10

162 63 6448 50 51

- 455 ~ 20 5 ~ 22

10 ~ 43 10 ~ 46R-410A

1.7 2.951

206

EWAQ-ACV3

EWAQ005AC

Page 8: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Mini-Chiller

› Optimised for use with R-410A

› Inverter controlled swing compressor

› Inverter controlled scroll compressor

› ESEER up to 4.57

› PE treated condenser coil

› Built-in hydraulic module

› Sound operation down to 62dBA

› Built-in hydraulic module

› Adaptive control possibility

BRC1D52

HEATING & COOLINGCAPACITY CLASS

Capacity Cooling kWHeating kW

Power input Cooling kWHeating kW

EERESEERCOPDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Type Brazed plate

Water volume lMinimum water volume in the system lWater flow rate Min l/minNominal Water Flow Cooling l/min

Heating l/minAir heat exchanger Type Tube type Hi-XSSExternal static pressure Cooling kPa

Heating kPaExpansion vessel Volume lCompressor Type Hermetically sealed swing compressor Inverter hermetically sealed scroll compressor

Model QuantitySound Power Cooling dBA

Heating dBASound Pressure Cooling Rated dBA

Night quiet dBAHeating Rated dBA

Night quiet dBAOperation Range Water side Cooling °CDB

Heating °CDBAir side Cooling °CDB

Heating °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Inverter Electronic expansion valve

Power Supply 1~/230V/50HzPiping connections Water heat exchanger inlet, outlet / drain 1'' mbsp / hose nipple 1/2'' fbsp -

Piping / Diameter Inch - 3 / G 5/4/"

005 006 007 009 010 011

5.2 6.0 7.1 8.5 9.5 11.05.65 6.35 7.75 10.0 11.5 13.01.89 2.35 2.95 2.74 3.19 3.821.97 2.24 2.83 2.91 3.38 3.862.75 2.55 2.41 3.11 2.98 2.88

- 4.57 4.52 4.462.87 2.83 2.74 3.44 3.40 3.37

805 x 1,190 x 360 1,435 x 1,418 x 382100 180104 -

- 1.0110 -12 16

14.9 17.2 20.4 24.4 27.2 31.517.5 19.5 23.5 28.7 33.0 37.5

49.4 45.1 38.3 60.2 57.5 53.044.5 40.3 30.7 55.2 50.0 41.8

6 10

162 63 64

- 6448 50 51

- 4548 49 51

- 425 ~ 20 5 ~ 22

25 ~ 50 25 ~ 50 10 ~ 43 10 ~ 46-15 ~ 25 -15 ~ 35

R-410A1.7 2.95

1

207

EWYQ-ACV3

EWYQ009AC

Page 9: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Mini-Chiller

› Optimised for use with R-410A

› Inverter controlled scroll compressor

› ESEER up to 4.68

› Built-in hydraulic module

- No buffer tank required

- Standard pump included

- Option high pump

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWEERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Type Brazed plate

Water volume lMinimum water volume in the system lWater flow rate Min l/minNominal Water Flow Cooling l/min

Air heat exchanger Type Hi-XSSExternal static pressure Cooling kPaExpansion vessel Volume lCompressor Type Inverter hermetically sealed scroll compressor

Model QuantitySound Power Cooling dBASound Pressure Cooling Rated dBA

Night quiet dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3N~/400V/50HzPiping connections Water heat exchanger inlet, outlet / drain

Piping / Diameter Inch 3 / G 5/4

BRC1D52

009 011 013

9.0 11.0 13.22.96 3.82 5.103.04 2.88 2.594.68 4.63 4.52

1,435 x 1,418 x 382180

-

1.01-

1625.8 31.5 37.8

58.9 53.0 45.710

164 6651 52

455 ~ 22

10 ~ 46R-410A

2.951

-

208

EWAQ-ACW1

EWAQ009AC

Page 10: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Mini-Chiller

› Optimised for use with R-410A.

› Inverter controlled scroll compressor

› ESEER up to 4.68

› Built-in hydraulic module

- No buffer tank required

- Standard pump included

- Option high pump

BRC1D52

HEATING & COOLINGCAPACITY CLASS

Capacity Cooling kWHeating kW

Power input Cooling kWHeating kW

EERESEERCOPDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Type Brazed plate

Water volume lMinimum water volume in the system lWater flow rate Min l/minNominal Water Flow Cooling l/min

Heating l/minAir heat exchanger Type Hi-XSSExternal static pressure Cooling kPa

Heating kPaExpansion vessel Volume lCompressor Type Inverter hermetically sealed scroll compressor

Model QuantitySound Power Cooling dBA

Heating dBASound Pressure Cooling Rated dBA

Night quiet dBAHeating Rated dBA

Night quiet dBAOperation Range Water side Cooling °CDB

Heating °CDBAir side Cooling °CDB

Heating °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3N~/400V/50HzPiping connections Water heat exchanger inlet, outlet / drain -

Piping / Diameter Inch 3 / G 5/4

009 011 013

9.0 11.0 13.211.0 12.5 14.02.96 3.82 5.103.23 3.70 4.193.04 2.88 2.594.68 4.63 4.523.41 3.38 3.34

1,435 x 1,418 x 382180

-

1.01-

1625.8 31.5 37.831.5 35.8 40.1

58.9 53.0 45.751.9 44.2 36.7

10

164 66

6451 52

4551

42 435 ~ 22

25 ~ 50 10 ~ 46-15 ~ 35R-410A

2.951

209

EWYQ-ACW1

EWYQ009AC

Page 11: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Centrifugal Fan

› Optimised for use with R-407C

› Daikin scroll compressor

› Electronic DDC controller

› Standard phase sequence controller

› High static pressure (up to 150Pa)

› Pressure gauges

› Standard operation range down to -10°C

› Regulating switch

› Water inlet or outlet temperature control

› Input contacts / available outputs

› Input: ON/OFF (per circuit), Pump/flow switch

› Output: compressor operation, summary alarm, pump relay contact

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps %EERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Brased plate, one per circuitMinimum water volume in the system lWater flow rate

Min l/minNominal l/minMax l/min

Air heat exchanger Type Cross fin coil/Hi-X tubes and PE coated waffle louvre finsFan Nominal air flow m³/minCompressor Type Hermetically sealed scroll compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Thermostatic expansion valve

Power Supply 3N~/400V/50HzPiping connections Evaporator water inlet/outlet fbsp 1''

Evaporator water drain field installation

5 8 10

11.6 18.4 23.85.25 7.78 9.85

0-1002.21 2.37 2.42

1,345 x 856 x 630 1,290 x 1,180 x 630 1,395 x 1,330 x 630164 224 261166 228 266

101 153 21216 23 2833 53 6864 92 112

1.17 1.83 2.10

163 66 69

-10 (OPZL) ~ 21-10 ~ 43R-407C

2.1 3.9 4.71

210

EUWAC-FZW

MICRO CHILLER

EUWAC8FZW

Page 12: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a
Page 13: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled

› Optimised for use with R-407C

› Daikin scroll compressor

› Reduced installation time thanks to integrated pump and/or buffer tank

› Possibility for a 200 l buffer tank (KAZ-series)

› Low operating sound level

› Improved serviceability

› Main switch

› Water flow switch

› 3 different design options available

› EUWAN chiller without integrated hydraulic module

› EUWAP chiller with integrated hydraulic module (pump,

expansion vessel, hydraulic components)

› EUWAB chiller with integrated hydraulic module (buffer

tank, pump, expansion vessel, hydraulic components)

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps %EERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Brased plateMinimum water volume in the system lWater flow rate

Min l/minNominal l/minMax l/min

Air heat exchanger Type Cross fin coil/Hi-X tubes and PE coated waffle louvre finsNominal static height unit Heating kPaBuffer tank volume Volume lFan Nominal air flow m³/minCompressor Type Hermetically sealed scroll compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Thermostatic expansion valve

Power Supply 3N~/400V/50HzPiping connections Evaporator water inlet/outlet MBSP 1-1/4'' 2''

Evaporator water drain 15 mm

N5 P5 B5 N8 P8 B8 N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24

11.3 17.9 22.5 26.5 37.0 46.6 55.34.52 4.64 7.38 7.39 8.79 8.74 11.50 15.2 15.0 18.1 17.9 24.0

0-100 0-50-1002.51 2.44 2.42 2.56 2.57 2.30 2.42 2.47 2.57 2.60 2.30

1,230 x 1,290 x 734 1,450 x 1,290 x 734 1,321 x 2,580 x 734 1,541 x 2,580 x 734150 168 180 215 229 241 245 259 271 248 262 274 430 448 460 490 508 520 496 514 526152 171 239 218 232 300 248 262 330 251 265 335 436 457 525 496 518 586 503 524 592

54 85 108 126 88 111 13216 26 32 38 53 67 7932 51 64 76 106 134 15865 102 129 152 212 267 317

- 205 205 - 154 154 - 123 123 - 105 105 - 187 187 - 137 137 - 100 100- - 55 - - 55 - - 55 - - 55 - - 55 - - 55 - - 55

160 170 2x 170

1 267 76 78 79 81

-10 (OPZL) ~ 25-15 ~ 43R-407C

3.9 4.6 6.0 4.6+4.6 5.9+5.9 6.0+6.01 2

212

EUWA*-KAZW

MICRO CHILLER

EUWAN16KAZW

Page 14: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled

› Optimised for use with R-407C

› Daikin scroll compressor

› Reduced installation time thanks to integrated pump and/or buffer tank

› Possibility for a 200 l buffer tank (KAZ-series)

› Low operating sound level

› Improved serviceability

› Main switch

› Water flow switch

› 3 different design options available

› EUWYN chiller without integrated hydraulic module

› EUWYP chiller with integrated hydraulic module (pump,

expansion vessel, hydraulic components)

› EUWYB chiller with integrated hydraulic module (buffer

tank, pump, expansion vessel, hydraulic components)

HEATING & COOLINGCAPACITY CLASS

Capacity Cooling kWHeating kW

Power input Cooling kWHeating kW

Capacity Steps %EERCOP (Eurovent)Dimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Type Brased plate

Minimum water volume in the system lWater flow rate

Min l/minMax l/min

Nominal Water Flow

Cooling l/minHeating l/min

Nominal water pressure drop

Cooling kPaHeating kPa

Air heat exchanger Type Cross fin coil/Hi-X tubes and PE coated waffle louvre finsNominal static height unit Heating kPaBuffer tank volume Volume lFan Nominal air flow m³/minCompressor Type Hermetically sealed scroll compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Cooling °CDB

Heating °CDBAir sidetemperature

Cooling °CDBHeating °CDB

Refrigerant circuit Refrigerant typeRefrigerant charge kgNo of circuitsRefrigerant control Thermostatic expansion valve

Power Supply 3N~/400V/50HzPiping connections Evaporator water inlet/outlet MBSP 1-1/4'' 2''

Evaporator water drain 15mm

N5 P5 B5 N8 P8 B8 N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24

9.1 17.1 21.0 25.0 34.2 40.0 50.011.9 18.5 24.0 27.0 37.0 46.0 54.03.78 7.45 7.46 8.57 11.4 14.9 16.3 22.84.59 7.10 9.10 10.8 14.2 17.4 21.6

0-100 0-50-1002.40 2.30 2.45 2.20 2.30 2.45 2.20

2.60 2.64 2.50 2.61 2.64 2.501,230 x 1,290 x 734 1,450 x 1,290 x 734 1,321 x 2,580 x 734 1,541 x 2,580 x 734

163 181 193 227 241 253 258 272 284 258 272 284 455 473 485 516 534 546 516 534 546165 184 252 230 244 312 261 275 343 261 275 343 461 482 550 522 544 612 522 544 612

43 82 100 119 82 96 11921 31 38 45 61 72 8968 106 137 155 212 263 30926 49 60 72 98 115 14334 53 69 77 106 132 15510 25 24 33 12 1917 29 31 38 14 16 22

- 205 - 160 - 127 - 100 - 195 - 147 - 111- 55 - 55 - 55 - 55 - 55 - 55 - 55

160 170

1 267 76 78 79 81

-10 (OPZL) ~ 2035 ~ 50-15 ~ 43-10 ~ 21R-407C

4.6 4.7 5.4 10.2 10.8 11.21 2

213

EUWY*-KAZW

MICRO CHILLER

EUWYN16KAZW

Page 15: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Multiple Scroll

› R-410A refrigerant

› Multiple compressors per circuit

› Reliable and efficient scroll with high EER values

› Good part load efficiency (seasonal EER)

› Anti-corrosion treated aluminium coils

› Low operating noise levels

› Easy 'plug and play' installation

› Fans protected against abnormal operation

(4 - 8 fans depending on unit size)

› Safety valves in each circuit

› Electronic circuit breakers

› Electronic expansion valve

› True dual plate brazed plate heat exchanger

› All hydronics can be accessed easily from 3 sides (no surrounding cabinet)

› Separate switchbox for easy access

› Compressors and controls at side of unit

› Increased reliability via 2 independent refrigerant

circuits (EWAQ130-260DAYN)

› Double circuit heat exchanger (from >100 kW)

› Non hermetic filter/dryer

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps %EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Type Brased plate

Minimum water volume in the system lWater flow rate

Min l/minMax l/min

Nominal Water Flow Cooling l/minNominal water pressure drop Cooling kPa

Air heat exchanger Type Cross fin coil / Hi-Xss tubes and PE coated waffle finsFan Nominal air flow m³/min

Speed rpmCompressor Type Scroll compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Water heat exchanger inlet / outlet 3"od 3"

Water heat exchanger drain 1/2"g

080 100 130 150 180 210 240 260

80 105 131 152 182 209 236 25426.4 36.2 46.6 56.3 64.5 74.6 82.8 94.0

0-50-100 0-25-50-75-100 21/29-43/50/57-71/79-100 0-25-50-75-100 22/28-40/50/56-72/78-100 0-25-50-75-1003.03 2.90 2.81 2.70 2.82 2.80 2.85 2.704.12 4.00 4.34 4.22 4.36 4.32 4.20 4.002,311 x 2,000 x 2,566 2,311 x 2,000 x 2,631 2,311 x 2,000 x 3,081 2,311 x 2,000 x 4,850

1,350 1,400 1,500 1,550 1,800 1,850 3,150 3,2501,365 1,415 1,517 1,569 1,825 1,877 3,189 3,292

358 470 295 341 408 468 529 569115 151 188 218 261 300 339 364459 602 754 871 1,043 1,198 1,355 1,456229 301 377 436 522 599 677 72859 58 52 49 52 53 51 47

780 800 860 1290 1600880 900 970 900

2 486 88 89 90 91

-10 (OPZL) ~ 25-15 ~ 43R-410A

33 19+19 25+25 29+29 28+28 39+391 2

214

EWAQ-DAYN

PCASO

EWAQ130-150DAYN

Page 16: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Multiple Scroll

› R-410A refrigerant

› Multiple compressors per circuit

› Reliable and efficient scroll with high EER values

› Good part load efficiency (seasonal EER)

› Anti-corrosion treated aluminium coils

› Low operating noise levels

› Easy 'plug and play' installation

› Fans protected against abnormal operation (4 - 8 fans depending on unit size)

› Safety valves in each circuit

› Electronic circuit breakers

› Electronic expansion valve

› True dual plate brazed plate heat exchanger

› All hydronics can be accessed easily from 3 sides (no surrounding cabinet)

› Separate switchbox for easy access

› Compressors and controls at side of unit

› Increased reliability via 2 independent refrigerant circuits (EWYQ130-250DAYN)

› Double circuit heat exchanger (from >100 kW)

› Non hermetic filter/dryer

HEATING & COOLINGCAPACITY CLASS

Capacity Cooling kWHeating kW

Power input Cooling kWHeating kW

Capacity Steps %EERCOP (Eurovent)ESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Type Brased plate

Minimum water volume in the system lWater flow rate

Min l/minMax l/min

Nominal Water Flow

Cooling l/minHeating l/min

Nominal water pressure drop

Cooling kPaHeating kPa

Air heat exchanger Type Cross fin coil / Hi-Xss tubes and PE coated waffle finsFan Nominal air flow m³/min

Speed rpmCompressor Type Scroll compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Cooling °CDB

Heating °CDBAir side Cooling °CDB

Heating °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Water heat exchanger inlet / outlet 3"od 3"

Water heat exchanger drain 1/2"g 1/2"g

080 100 130 150 180 210 230 250

77.0 100 136 145 183 211 231 25287.7 114 149 165 199 225 258 28126.5 36.2 47.6 55.7 63.8 75.3 82.2 93.530.0 38.1 49.6 58.8 68.0 77.0 84.2 96.6

0-50-100 0-25-50-75-100 21/29-43/50/57-71/79-100 0-25-50-75-100 22/28-44/50/56-72/78-100 0-25-50-75-1002.91 2.76 2.86 2.6 2.87 2.80 2.81 2.702.92 2.99 3 2.81 2.93 2.92 3.06 2.914.00 3.81 4.31 4.07 4.33 4.23 4.20 4.002,311 x 2,000 x 2,566 2,311 x 2,000 x 2,631 2,311 x 2,000 x 3,081 2,311 x 2,000 x 4,850

1,400 1,450 1,550 1,600 1,850 1,900 3,200 3,3001,415 1,465 1,567 1,619 1,875 1,927 3,239 3,342

393 511 334 370 446 504 578 629110 143 195 208 262 302 331 361503 654 854 946 1,141 1,290 1,479 1,611221 287 390 416 525 605 662 722251 327 427 473 570 645 740 806

36 43 38 41 44 39 3847 46 51 49 48 50 48 46

780 800 860 1,290 1,600880 900 970 900

2 486 88 89 90 91

-10 (OPZL) ~ 2525 ~ 50-15 ~ 43-10 ~ 21R-410A

33 37 22+22 32+32 39+391 2

215

EWYQ-DAYN

PCASO

EWYQ130-150DAYN

Page 17: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled

› All models are PED pressure vessel approved

› Daikin semi-hermetic single screw stepless compressor

› Optimised for use with R-134a

› Advanced pCO² DDC controller

› Standard operation range down to -15°C ambient

› High quality, anti-corrosion treated components as standard

› Reverse phase protection as standard

› Moisture indicator as standard

› Victaulic joints as standard

› Flow switch as standard

› Low operating sound level - extra low noise option available

› DICN (Daikin Integrated Chiller Network) operation

as standard within same series

› Evaporator heater tape as standard on all units

› Double refrigeration circuit (from 240kW on)

› Chilled water temperatures down to -10°C on standard unit (parameter in

the service menu of the PCO² digital controller must be set by the installer)

› Hi-esp fans (up to 150Pa) available as option

› High energy efficiency ratio

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 30-100 (stepless) 15-100 (stepless)EERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Type Shell and tube

Minimum water volume in the system lWater flow rate

Min l/minMax l/min

Nominal Water Flow Cooling l/minNominal water pressure drop Cooling kPa

Air heat exchanger Type Cross fin coil/Hi-X tubes and PE coated waffle louvre finsFan Nominal air flow m³/min

Speed rpmCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Thermostatic expansion valve Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet 3'' victaulic coupling 4'' victaulic coupling 5'' victaulic coupling 6'' victaulic coupling

Evaporator water drain 1/2'' g-f uni-iso 228/1

120 150 170 240 300 340 380 460 520 600

121 149 171 226 286 330 372 449 525 60541.1 54.1 64.9 83.7 105 136 130 170 210 263

2.94 2.75 2.63 2.7 2.72 2.43 2.86 2.64 2.5 2.32,221x3,973x1,109 2,250 x 4,280 x 2,238 2,250 x 5,901 x 2,238

1,391 1,600 1,705 2,710 3,210 3,260 5,335 5,595 5,775 5,8551,441 1,663 1,768 2,790 3,340 3,390 5,497 5,779 5,959 6,039

590 730 840 550 700 810 910 1,100 1,280 1,480150 200 300 395 540 640 870490 725 930 1,165 1,580 1,880345 427 492 649 820 946 1,066 1,287 1,505 1,73440.1 18.6 24.8 41 36.6 49.1 20.8 25.6 35.1 46.6

960 1,920 2,880730 900 730 900

1 287 94 92 90 97 95 97 98 100 101

-10 ~ 16-15 ~ 43R-134a

26 37 42 30+30 41+41 44+44 65+65 65+70 70+701 2

216

EWAD-MBYN

pCO2

EWAD170MBYN

Page 18: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Standard Efficiency

› Stepless single-screw compressor

› Optimised for use with R-134a

› 2 truly independent refrigerant circuits

› Standard anti-corrosion treated

› DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops

› Fitted standard with evaporator heater tape

› Condenser protection grilles are available throughout the whole range

› All models are PED pressure vessel approved

› Partial and total heat recovery option available

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 12.5 - 100 (stepless)EERESEER

Dimensions Height x Width x Depth mm

Weight Machine weight kgOperating Weight kg

Water Heat Exchanger Evaporator

Type Plate to plate heat exchanger Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaAir heat exchanger Type Grooved tubes and ALU coated louvred finsFan Nominal air flow m³/min

Speed rpmCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet 3" 4" 5.5''

Evaporator water drain 1/2'' gas

190 200 230 260 280 300 320 340 360 400 440 480 500 550 600

184.0 197.8 225.0 245.0 261.0 275.0 298.4 321.0 370.0 401.3 451.0 478.7 510.1 551.0 588.081.3 79.6 84.6 93.5 101.3 108.3 119.4 123.4 133.4 155.7 167.0 177.6 186.9 195.6 202.9

2.26 2.48 2.66 2.62 2.58 2.54 2.5 2.6 2.77 2.58 2.7 2.73 2.82 2.93.17 3.46 3.59 2.52 3.58 3.66 3.53 3.80 2.58 3.24 3.23 3.09 3.17 3.23

2,340 x 2,235 x 2,240 2,340 x 2,235 x 3,140 2,340 x 2,235 x

4,0402,340 x 2,235

x 3,140 2,340 x 2,235 x 4,040

2,380 2,466 2,766 2,806 2,846 3,166 3,186 3,552 3,932 3,997 4,052 4,092 4,1222,405 2,497 2,859 2,896 2,936 3,279 3,299 3,680 4,102 4,161 4,216 4,252 4,282

25 31 93 90 113 128 170 164 160311 374 327 333 361 368 503 512 920.32 1,240.87 1,317.08 1,403.20 1,516.00 1,617.81527 567 645 702 748 788 855 920 1,061 1,150.41 1,292.57 1,371.96 1,461.67 1,579.17 1,685.22985 1,182 1,033 1,053 1,141 1,162 1,164 1,590 1,618 1,380.49 1,551.09 1,646.35 1,754.00 1,895.01 2,022.2628.7 23 39 44.5 43 46 54 33.5 43 49.7 59.1 52.2 57.4 54.1 60

918 894 1,374 1,356 1,338 1,836 1,938 2,694 2,640 2,580900 890

293.7 94.3 94.7 97.2 95.8 96.7 98.2 98.7

-8~15-18 (OPLA)~44

R-134a36 42 48 50 54 58 66 56 70 76 82 87 92

2

217

EWAD-AJYNN

pCO2

EWAD300AJYNN

Page 19: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - High Efficiency

› High efficiency

› Stepless single-screw compressor

› Optimised for use with R-134a

› 2 truly independent refrigerant circuits

› Standard anti-corrosion treated

› DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops

› Fitted standard with evaporator heater tape

› Condenser protection grilles are available throughout the whole range

› All models are PED pressure vessel approved

› Partial and total heat recovery option available

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 12.5 - 100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaAir heat exchanger Type Grooved tubes and ALU coated louvred finsFan Nominal air flow m³/min

Speed rpmCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet 4" 6.5''

Evaporator water drain 1/2'' gas

260 280 320 340 360 380 420 500 550 600 650

247.0 275.0 301.5 327.0 351.0 376.0 401.0 501.4 531.5 582.2 626.679.2 87.3 94.2 103.8 112.8 120.2 127.5 160.6 170.9 183.5 195.4

3.12 3.15 3.20 3.15 3.11 3.13 3.15 3.12 3.11 3.17 3.213.99 3.89 4.01 4.04 3.91 3.63 3.60 3.61 3.56 3.37

2,340 x 2,235 x 3,140 2,340 x 2,235 x4,040 2,340 x 2,235 x 4,9402,866 3,186 3,286 3,366 3,376 3,321 3,386 4,252 4,642 4,6522,959 3,299 3,399 3,530 3,535 3,480 3,545 4,515 4,905 4,908

93 113 164 159 263 256373 489 495 537 586 593 598 1,152.09 1,221.25 1,337.75 1,439.77708 788 864 937 1,006 1,078 1,150 1,440.11 1,526.57 1,672.19 1,799.71

1,180 1,546 1,565 1,697 1,853 1,876 1,890 1,728.14 1,831.88 2,006.63 2,159.6636.0 26.0 30.5 29.5 33.0 37.0 56.6 66.2 55.9 62.7

1,338 1,836 1,782 2,640 2,580 3,228900 890

296.8 97.2 99.7 98.7 99.2

-8~15-18 (OPLA)~48

R-134a58 66 76 73 76 86 100

2

218

EWAD-AJYNN/A

pCO2

EWAD-AJYNN/A

Page 20: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Standard Efficiency - Extra Low Noise

› Standard efficiency - extra low noise

› Stepless single-screw compressor

› Optimised for use with R-134a

› 2 truly independent refrigerant circuits

› Standard anti-corrosion treated

› DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops

› Fitted standard with evaporator heater tape

› Condenser protection grilles are available throughout the whole range

› All models are PED pressure vessel approved

› Partial and total heat recovery option available

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 12.5 - 100 (stepless)EERESEER

Dimensions Height x Width x Depth mm

Weight Machine weight kgOperating Weight kg

Water Heat Exchanger Evaporator

Type Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaAir heat exchanger Type Grooved tubes and ALU coated louvred finsFan Nominal air flow m³/min

Speed rpmCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet 4" 5.5''

Evaporator water drain 1/2'' gas

210 240 260 280 300 320 340 400 440 460 500

203.0 231.1 252.7 270.8 286.1 299.4 308.8 400.5 428.5 458.4 500.879.8 85.2 93.7 104.5 114.5 126.1 136.3 156.0 173.8 182.4 189.9

2.54 2.71 2.70 2.59 2.50 2.37 2.27 2.57 2.47 2.51 2.643.86 4.05 4.02 3.96 3.83 3.73 3.57 3.40 3.33 3.30 3.29

2,340 x 2,235 x 3,140 2,340 x 2,235 x 4,040 2,340 x 2,235 x 4,940

3,046 3,366 3,466 3,546 3,556 3,567 3,722 3,912 3,9723,136 3,479 3,579 3,710 3,715 3,737 3,892 4,076 4,136

90 113 164 159 170 164364 474 483 518 566 572 571 918.27 982.47 1,051.02 1,148.24582 662 724 776 820 858 885 1,147.84 1,228.09 1,313.78 1,435.30

1,152 1,500 1,527 1,637 1,790 1,809 1,807 1,377.41 1,473.70 1,576.54 1,722.3625.5 19.5 22.5 21.0 22.5 24.0 47.2 53.9 48.3 54.1

774 1,074 1,032 1,704 1,644 1,926 2,208500

284.3 84.7 85.7 86.2

-8~15-10~44R-134a

58 62 66 71 76 81 862

219

EWAD-AJYNN/Q

pCO²

EWAD340AJYNN/Q

Page 21: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - High Ambient

› High ambient

› Stepless single-screw compressor

› Optimised for use with R-134a

› 2 truly independent refrigerant circuits

› Standard anti-corrosion treated

› DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops

› Fitted standard with evaporator heater tape

› Condenser protection grilles are available throughout the whole range

› All models are PED pressure vessel approved

› Partial and total heat recovery option available

COOLING ONLY

Capacity (Eurovent) Cooling kWNominal input (Eurovent) Cooling kWCapacity Steps % 12.5 - 100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Plate to plate heat exchanger Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaAir heat exchanger Type Grooved tubes and ALU coated louvred finsFan Nominal air flow m³/min

Speed rpmCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet 3" 4" 5.5''

Evaporator water drain 1/2'' gas

200 210 240 260 280 300 320 340 400 420 460 480 500 550 600

194.6 208.3 233.5 256.1 273.7 289.3 306.4 335.6 381.2 426.0 468.1 502.1 529.5 561.0 600.477.2 75.6 83.0 91.0 97.8 103.9 112.1 120.3 127.4 146.5 160.3 170.8 180.1 192.2 198.4

2.52 2.76 2.81 2.8 2.78 2.73 2.79 2.99 2.91 2.92 2.94 2.92 3.033.23 3.49 3.40 3.44 3.49 3.52 3.41 3.67 3.39 3.30 3.29 3.15 3.17 3.23

2,340 x 2,235 x 2,240 2,340 x 2,235 x 3,140 2,340 x 2,235 x 4,040 2,340 x 2,235 x 4,9402,380 2,466 2,766 2,806 2,846 3,166 3,186 3,942 4,202 4,277 4,332 4,392 4,4022,405 2,497 2,859 2,896 2,936 3,279 3,299 4,112 4,372 4,441 4,496 4,552 4,562

25 31 93 90 113 170 164 160314 378 331 337 366 369 373 507 518 976.74 1,073.26 1,151.22 1,214.04 1,286.27 1,376.60558 597 669 734 785 829 878 962 1,093 1,220.92 1,341.58 1,439.03 1,517.55 1,607.83 1,720.75994 1,194 1,045 1,065 1,157 1,167 1,179 1,603 1,638 1,465.11 1,609.90 1,726.83 1,821.07 1,929.40 2,064.9031.5 25.0 41.0 47.5 46.0 50.5 55.5 36.0 44.5 53.1 63.1 55.9 61.4 55.9 61.6

1,434 1,368 2,154 2,100 2,046 2,874 2,580 3,372 3,300 3,228900 890

298.2 98.8 99.2 101 96.7 97.7 99.2 99.7

-8~15-18 (OPLA)~48

R-134a36 42 44 55 56 58 66 70 90 95 100

2

220

EWAD-AJYNN/H

CAPACITY CLASS

Capacity

Power input

pCO2

EWAD400AJYNN/H

Page 22: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Standard Seasonal Inverter

› All models are PED pressure vessel approved

› Inverter stepless single-screw compressor

› Optimised for use with R-134a

› 2 truly independent refrigerant circuits

› DX shell and tube evaporator - one pass refrigerant

side to minimize pressure drops

› Quick start-up

› Standard electronic expansion valve

› ESEER up to 4.70

› Good part load efficiency

› Power factor >0.95

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 13.5-100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger evaporator

Type Shell and tubeMinimum water volume in the system lWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaAir heat exchanger Type Louvered finsFan Nominal air flow m³/min

Speed rpmCompressor Type Single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB -9.5 (OPZL) ~ 15

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

330 360 400 420 460 490 520

329 358 395 423 459 488 515120 136 147 159 168 181 193

2.74 2.63 2.68 2.66 2.74 2.71 2.674.59 4.60 4.55 4.59 4.57 4.70 4.60

2,355 x 2,234 x 4,381 2,355 x 2,234 x 5,281 2,355 x 2,234 x 6,1814,190 4,590 4,9904,440 4,840 5,240

1,277 1,389 1,533 1,641 1,781 1,893 1,998271 264 256 248515 565 622 673 727 768 814943 1,026 1,132 1,213 1,316 1,399 1,476

1,360 1,491 1,637 1,759 1,935 2,025 2,13960 61 72 67 78 69 76

1,960 2,450 2,940700

2102.8 103.2 103.6

-10~45R-134a

73 99 105 114 118 1212

168.3

221

EWAD-AJYNN/S

pCO2

EWAD-AJYNN/S

Page 23: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - High Seasonal Efficiency Inverter

› High seasonal efficiency inverter

› ESEER up to 5.01

› All models are PED pressure vessel approved

› Inverter stepless single-screw compressor

› Optimised for use with R-134a

› EER up to 2.79

› 2 truly independent refrigerant circuits

› DX shell and tube evaporator – one pass

refrigerant side to minimize pressure drops

› Good part load efficiency

› Power factor > 0.95

› Quick start-up

› Standard electronic expansion valve

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 13.5-100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger evaporator

Type Shell and tubeMinimum water volume in the system lWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaAir heat exchanger Type Louvered finsFan Nominal air flow m³/min

Speed rpmCompressor Type Single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Water side Min~Max °CDB -9.5 (OPZL) ~ 15

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm 168.3

330 360 400 420 460 490 520

329 358 395 423 459 488 515118 135 145 157 165 178 190

2.78 2.66 2.73 2.70 2.79 2.75 2.714.79 4.82 4.78 4.84 4.81 5.01 4.84

2,355 x 2,234 x 4,381 2,355 x 2,234 x 5,281 2,355 x 2,234 x 6,1814,190 4,590 4,9904,440 4,840 5,240

1,277 1,389 1,533 1,641 1,781 1,893 1,998271 264 256 248515 565 622 673 727 768 814943 1,026 1,132 1,213 1,316 1,399 1,476

1,360 1,491 1,637 1,759 1,935 2,025 2,13960 61 72 67 78 69 76

1,960 2,450 2,940700

2102.8 103.2 103.6

-10~45R-134a

73 99 105 114 118 1212

222

EWAD-AJYNN/X

pCO2

EWAD-AJYNN/X

Page 24: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a
Page 25: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Heat Pump Inverter

› Optimised for use with R-134a

› Cooling range: 254 - 583 kW

› Heating range: 270 - 615 kW

› EER range up to 2.87

› Standard electronic expansion valave

› DX shell and tube evaporator - one pass refrigerant

side to minimize pressure drops

› Seasonal quietness

› Low starting current

› No gas boiler required

› Optimised defrost cycles

› Optimum ESEER values

› Partial and heat recovery option available

› PID microprocessor control

› Power factor up to 0.95

› 2-3 truly independent refrigerant circuits

› Standard operation range down to -12°C

› Available in two sound level configurations

HEATING & COOLINGEWYD-BZSS (Standard efficiency - Standard noise)

Capacity Cooling kWHeating kW

Power input Cooling kWHeating kW

Capacity Steps % 13 - 100 (stepless) 9 - 100 (stepless)EERCOPESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating weight kgWater Heat Exchanger Type Single pass shell and tube

Water volume lNominal water flow rate

Cooling l/sHeating l/s

Nominal water pressure drop

Cooling kPaHeating kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Nominal air flow l/s

Speed rpmCompressor Type Semi-hermetic single screw compressor Inverter driven

Quantity No.Sound level Sound Power Cooling dBA

Heating dBASound Pressure Cooling dBA

Heating dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

250 270 290 320 340 370 380 410 440 460 510 520 580

254 273 292 324 339 365 382 413 436 457 505 522 583270 297 324 333 349 379 410 443 463 475 530 558 61590.3 100 109 116 124 134 142 152 163 161 178 186 21590.4 99 107 117 124 132 141 155 165 164 176 184 205

2.81 2.74 2.69 2.79 2.74 2.73 2.68 2.72 2.68 2.83 2.83 2.81 2.712.98 2.99 3.03 2.84 2.80 2.87 2.90 2.85 2.81 2.90 3.02 3.04 3.004.05 4.04 4.01 4.07 4.01 4.02 3.94 4.03 4.01 4.31 4.13 4.13 4.05

2,335x2,254x3,547 2,335x2,254x4,381 2,335x2,254x5,281 2,335x2,254x6,5833,410 3,455 3,500 3,870 3,940 4,010 4,390 5,015 5,495 5,735 5,7353,550 3,595 3,640 4,010 4,068 4,138 4,518 5,255 5,724 5,964 5,953

138 133 128 240 229 21812.12 13.03 13.94 15.46 16.21 17.42 18.25 19.72 20.81 21.83 24.11 24.92 27.8712.89 14.18 15.49 15.89 16.66 18.11 19.57 21.15 22.14 22.68 25.33 26.65 29.39

37 42 48 53 58 53 57 46 51 61 50 53 6542 49 58 55 60 57 65 52 57 66 55 60 71

31,728 42,304 52,880 63,456920

2 3100.5 101.2 101.8 103.6100.5 101.2 101.8 103.682.1 82.3 82.5 83.7

82.1 82.3 82.5 83.7-8~15

-10~45R-134a

88 94 100 118 121 124 148 177 183 1862 3

139.7 219.1

224

EWYD-BZ

EWYD250BZSS

Page 26: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

HEATING & COOLINGEWYD-BZSL (Standard effi ciency - Low noise)

Capacity Cooling kWHeating kW

Power input Cooling kWHeating kW

Capacity Steps % 13 - 100 (stepless) 9 - 100 (stepless)EERCOPESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating weight kgWater Heat Exchanger Type Single pass shell and tube

Water volume lNominal water fl ow rate

Cooling l/sHeating l/s

Nominal water pressure drop

Cooling kPaHeating kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Nominal air fl ow Cooling l/s

Heating l/sSpeed Cooling rpm

Heating rpmCompressor Type Semi-hermetic single screw compressor

Quantity No.Sound level Sound Power Cooling dBA

Heating dBASound Pressure Cooling dBA

Heating dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

250 270 290 320 330 360 370 400 430 450 490 510 570

248 266 291 316 331 355 372 403 425 448 493 510 567270 297 324 333 349 379 410 443 463 475 530 558 61588.5 98.0 109.0 113.0 122.0 132.0 142.0 149.0 161.0 156.0 174.0 183.0 214.090.4 99.0 107.0 117.0 124.0 132.0 141.0 155.0 165.0 164.0 176.0 184.0 205.0

2.80 2.70 2.66 2.79 2.72 2.68 2.62 2.71 2.64 2.87 2.83 2.79 2.652.98 2.99 3.03 2.84 2.80 2.87 2.90 2.85 2.81 2.90 3.02 3.04 3.004.18 4.16 4.11 4.29 4.18 4.16 4.13 4.19 4.14 4.31 4.29 4.23 4.10

2,335 x 2,254 x 3,547 2,335 x 2,254 x 4,381 2,335 x 2,254 x 5,281 2,335 x 2,254 x 6,5833,750 3,795 3,840 4,210 4,280 4,350 4,730 5,525 6,005 6,245 6,2453,888 3,933 3,978 4,343 4,408 4,478 4,858 5,765 6,234 6,474 6,463

138 133 128 240 229 21811.83 12.70 13.89 15.12 15.83 16.98 17.77 19.28 20.30 21.39 23.56 24.34 27.1112.89 14.18 15.49 15.89 16.66 18.11 19.57 21.15 22.14 22.68 25.33 26.65 29.39

36 40 48 51 55 50.32 54.62 44.07 48.40 59.16 48 51 6242 49 58 55 60 57 65 52 57 66 55 60 71

24,432 32,576 40,720 48,86431,728 42,304 52,880 63,456

715920

2 394.0 94.7 95.3 97.094.9 96.1 96.7 98.475.6 75.8 76.0 77.276.5 77.2 77.4 78.6

-8~15-10~45R-134a

88 94 100 118 121 124 148 177 183 1862 3

139.7 219.1

225

Page 27: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Standard Efficiency

› Standard efficiency

› All models are PED pressure vessel approved

› Stepless single-screw compressor

› Optimised for use with R-134a

› 11 sizes to cover a range from 647 up to 1,714 kW

› EER range up to 2.93

› 2-3 truly independent refrigerant circuits

› Standard electronic expansion valve

› DX shell and tube evaporator - one pass refrigerant

side to minimize pressure drops

› Available in three sound level configurations

› Partial and heat recovery option available

› New MicroTech III controller

COOLING ONLY EWAD~C-SS/SL (Standard noise / Low noise)

Capacity (Eurovent) Cooling kWNominal input (Eurovent) Cooling kWCapacity Steps % 12.5 - 100 (stepless) 7.0 - 100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight (EWAD~C-SS) Machine weight kg

Operating weight kgWeight (EWAD~C-SL) Machine weight kg

Operating weight kgWater Heat Exchanger Type Single pass shell and tube

Water volume lNominal water flow rate Cooling l/sNominal water pressure drop Cooling kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Nominal air flow l/s

Speed rpmCompressor Type Semi-hermetic single screw compressor

Quantity No.Sound level (EWAD~C-SS) Sound Power Cooling dBA

Sound Pressure Cooling dBASound level (EWAD~C-SL) Sound Power Cooling dBA

Sound Pressure Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

650 740 830 910 970 C11 C12 C14 C15 C16 C17

647 744 832 912 967 1,064 1,152 1,419 1,538 1,622 1,714221 262 299 318 351 378 402 500 551 580 618

2.93 2.84 2.78 2.87 2.76 2.82 2.86 2.84 2.79 2.8 2.773.95 3.87 3.89 3.84 3.8 3.88 3.84 3.88 3.9 3.87 3.78

2,540x2,285x6,185 2,540x2,285x7,085 2,540x2,285x7,985 2,540x2,285x10,185 2,540x2,285x11,0855,630 5,740 5,760 6,280 6,560 7,010 7,280 10,310 10,320 10,710 10,7705,910 5,990 6,010 6,530 6,810 7,250 7,520 10,730 11,110 11,2605,920 6,030 6,050 6,570 6,850 7,300 7,570 10,750 10,770 11,150 11,2106,200 6,280 6,300 6,820 7,100 7,540 7,810 11,170 11,550 11,700

266 251 243 421 408 47430.90 35.56 39.74 43.60 46.21 50.85 55.04 67.78 73.50 77.51 81.89

73 59 52 61 68 63 72 47 59 65 73

53,444 53,444 53,444 64,133 64,133 74,822 85,510 106,888 106,888 117,577 117,577920

2 399.5 100.0 100.9 101.1 101.5 101.7 102.9 103.0 103.2 103.379.0 79.5 80.4 80.6 81.0 81.1 81.296.0 96.1 97.5 97.1 97.6 98.1 99.1 99.5 99.575.5 75.6 76.5 76.6 76.8 76.9 77.2 77.3 77.4

-8~15-18~46R-134a

128 146 144 162 178 260 2612 3

168.3 219.1

226

EWAD-C-S

CapacityPower input

EWAD C14C-SL

Page 28: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

COOLING ONLYEWAD~C-SR (Reduced noise)

Capacity (Eurovent) Cooling kWNominal input (Eurovent) Cooling kWCapacity Steps % 12.5 - 100 (stepless) 7.0 - 100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating weight kgWater Heat Exchanger Type Single pass shell and tube

Water volume lNominal water fl ow rate Cooling l/sNominal water pressure drop Cooling kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Nominal air fl ow l/s

Speed rpmCompressor Type Semi-hermetic single screw compressor

Quantity No.Sound level Sound Power Cooling dBA

Sound Pressure Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

620 720 790 880 920 C10 C11 C13 C14 C15 C16

619 715 789 876 922 1,020 1,112 1,367 1,471 1,556 1,623223 272 315 331 369 395 417 517 576 603 647

2.77 2.62 2.51 2.65 2.5 2.59 2.67 2.64 2.55 2.58 2.514.08 3.96 3.98 3.99 4 3.96 3.96 3.9 3.87 3.9 3.83

2,540 x 2,285 x 6,185 2,540 x 2,285 x 7,085 2,540 x 2,285 x 7,985 2,540 x 2,285 x 10,185 2,540 x 2,285 x 11,0855,920 6,030 6,050 6,570 6,850 7,300 7,570 10,750 10,770 11,150 11,2106,200 6,280 6,300 6,820 7,100 7,540 7,810 11,170 11,550 11,700

266 251 243 421 408 47429.57 34.15 37.71 41.83 44.05 48.75 53.11 65.32 70.28 74.32 77.57

67 55 47 57 62 58 68 44 54 60 66

41,006 41,006 41,006 49,207 49,207 57,408 65,610 82,012 82,012 90,213 90,213715

2 391.5 92.0 92.5 93.0 93.5 93.8 94.8 94.9 95.1 95.271.0 71.5 72 72.5 72.6 72.7 72.9 73.0 73.1

-8~15-18~46R-134a

128 146 144 162 178 260 2612 3

168.3 219.1

227

CapacityPower input

Page 29: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - High Efficiency

› High efficiency

› All models are PED pressure vessel approved

› Stepless single-screw compressor

› Optimised for use with R-134a

› 14 sizes to cover a range from 756 up to 1,858 kW

› EER range up to 3.29

› 2-3 truly independent refrigerant circuits

› Standard electronic expansion valve

› DX shell and tube evaporator - one pass refrigerant

side to minimize pressure drops

› Available in three sound level configurations

› Partial and heat recovery option available

› New MicroTech III controller

COOLING ONLYEWAD~C-XS/XL (Standard noise / Low noise)

Capacity Cooling kWPower input Cooling kWCapacity Steps % 12.5 - 100 (stepless) 7.0 - 100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight (EWAD~C-XS) Machine weight kg

Operating weight kgWeight (EWAD~C-XL) Machine weight kg

Operating weight kgWater Heat Exchanger Type Single pass shell and tube

Water volume lNominal water flow rate Cooling l/sNominal water pressure drop Cooling kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Nominal air flow l/s

Speed rpmCompressor Type Semi-hermetic single screw compressor

Quantity No.Sound level (EWAD~C-XS) Sound Power Cooling dBA

Sound Pressure Cooling dBASound level (EWAD~C-XL) Sound Power Cooling dBA

Sound Pressure Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

760 830 890 990 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19

756 830 889 1,001 1,074 1,196 1,280 1,349 1,409 1,526 1,596 1,685 1,768 1,858233 253 278 307 338 364 400 411 437 474 504 533 561 590

3.25 3.28 3.2 3.26 3.18 3.29 3.2 3.29 3.23 3.22 3.17 3.16 3.15 3.154.02 4.11 4.02 4.11 4.05 4.14 4.02 4.28 4.23 4.19 4.17 4.16 4.13 4.13

2,540x2,285x6,185 2,540x2,285x7,085 2,540x2,285x7,985 2,540x2,285x9,785 2,540x2,285x11,985 2,540x2,285x12,885 2,540x2,285x13,785 2,540x2,285x14,6855,990 6,340 6,360 7,190 7,470 8,220 8,240 8,900 10,560 11,310 11,570 11,900 12,260 12,6006,240 6,580 6,600 7,600 7,870 8,610 8,630 9,890 11,040 12,170 12,430 12,760 13,140 13,4706,280 6,630 6,650 7,480 7,760 8,510 8,530 9,190 11,000 11,760 12,010 12,350 12,700 13,0406,520 6,870 6,890 7,880 8,160 8,900 8,920 10,180 11,490 12,610 12,870 13,200 13,580 13,910

251 243 403 386 979 491 850 871 85036.10 39.67 42.49 47.82 51.32 57.13 61.18 64.45 67.34 72.90 76.24 80.48 84.47 88.79

80 56 64 61 69 45 51 71 77 57 62 68 64 37

64,133 74,822 74,822 85,510 85,510 106,888 106,888 106,888 128,266 128,266 128,266 138,954 149,643 160,332920

2 3100.2 100.5 101.4 101.9 102.4 102.5 102.9 103.1 103.2 103.5 103.7 103.9

79.7 80.2 80.7 80.3 80.4 80.5 80.7 80.9 80.8 8196.8 97.4 98 98.2 98.8 98.9 99.6 100 100.2 100.476.3 76.5 76.9 77.1 76.7 76.8 77.1 77.2 77.3 77.4 77.5

-8~15-18~50R-134a

146 162 182 214 225 291 297 312 328 3432 3

168.3 219.1 273 219.1 273

228

EWAD-C-X

EWAD C12C-XR

Page 30: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

COOLING ONLYEWAD~C-XR (Reduced noise)

Capacity Cooling kWPower input Cooling kWCapacity Steps % 12.5 - 100 (stepless) 7.0 - 100 (stepless)EERESEER

Dimensions Height x Width x Depth mm

Weight Machine weight kgOperating weight kg

Water Heat Exchanger Type Single pass shell and tubeWater volume lNominal water fl ow rate Cooling l/sNominal water pressure drop Cooling kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Nominal air fl ow l/s

Speed rpmCompressor Type Semi-hermetic single screw compressor

Quantity No.Sound level Sound Power Cooling dBA

Sound Pressure Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

740 810 870 970 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19

736 811 866 974 1,041 1,168 1,247 1,302 1,378 1,486 1,550 1,639 1,722 1,813235 254 281 309 343 365 404 415 438 479 513 541 567 595

3.14 3.2 3.08 3.15 3.03 3.2 3.08 3.14 3.15 3.1 3.03 3.03 3.04 3.044.29 4.36 4.23 4.34 4.24 4.38 4.25 4.33 4.34 4.26 4.26 4.2 4.21 4.2

2,540 x 2,285 x 6,185

2,540 x 2,285 x 7,085

2,540 x 2,285 x 7,985 2,540 x 2,285 x 9,785 2,540 x 2,285 x 11,985 2,540 x 2,285

x 12,8852,540 x 2,285

x 13,7852,540 x 2,285

x 14,6856,280 6,630 6,650 7,480 7,760 8,510 8,530 9,190 11,000 11,760 12,010 12,350 12,700 13,0406,520 6,870 6,890 7,880 8,160 8,900 8,920 10,180 11,490 12,610 12,870 13,200 13,580 13,910

251 243 403 386 979 491 850 871 85035.17 38.74 41.36 46.54 49.76 55.78 59.56 62.21 65.85 70.98 74.07 78.32 82.30 86.61

76 54 61 58 65 43 49 67 74 54 59 65 61 35

49,207 57,408 65,610 82,012 98,414 106,616 114,817 123,018715

2 392 92.3 93.5 93.7 94.3 94.5 94.4 95.1 95.2 95.3 95.6 95.7 95.9

71.5 72.3 72.5 72.2 72.3 72.6 72.8 72.9 73.0-8~15

-18~50R-134a

146 162 182 214 225 291 297 312 328 3432 3

168.3 219.1 273 219.1 273

229

Page 31: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Air Cooled - Premium Efficiency

› Premium efficiency

› All models are PED pressure vessel approved

› Stepless single-screw compressor

› Optimised for use with R-134a

› 7 sizes to cover a range from 821 up to 1,390 kW

› EER range up to 3.64

› 2 truly independent refrigerant circuits

› Standard electronic expansion valave

› DX shell and tube evaporator - one pass refrigerant

side to minimize pressure drops

› Available in three sound level configurations

› Partial and heat recovery option available

› New MicroTech III controller

COOLING ONLYEWAD~C-PS/PL (Standard noise / Low noise)

Capacity (Eurovent) Cooling kWNominal input (Eurovent) Cooling kWCapacity Steps % 12.5 - 100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight (EWAD~C-PS) Machine weight kg

Operating weight kgWeight (EWAD~C-PL) Machine weight kg

Operating weight kgWater Heat Exchanger Type Single pass shell and tube

Water volume lNominal water flow rate Cooling l/sNominal water pressure drop Cooling kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Nominal air flow l/s

Speed rpmCompressor Type Semi-hermetic single screw compressor

Quantity No.Sound level (EWAD~C-XS) Sound Power Cooling dBA

Sound Pressure Cooling dBASound level (EWAD~C-XL) Sound Power Cooling dBA

Sound Pressure Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

820 890 980 C11 C12 C13 C14

821 890 975 1,074 1,158 1,279 1,390225 249 274 301 330 363 396

3.64 3.58 3.56 3.56 3.51 3.52 3.514.44 4.5 4.41 4.53 4.39 4.44 4.31

2,540x2,285x8,885 2,540x2,285x9,785 2,540x2,285x11,085 2,540x2,285x11,9857,530 7,660 8,290 8,550 9,390 9,7308,130 8,.700 9,330 9,590 10,380 10,7207,820 7,950 8,580 8,840 10,380 10,0208,420 8,990 9,620 9,880 10,670 11,010

599 1,043 1,027 995 97939.22 42.53 46.6 51.3 55.31 61.12 66.41

57 65 30 61 69 60 73

96,199 106,888 117,577 128,266920

2101 101.8 102.3 102.6 102.979.5 80.0 80.5 80.4 80.598.4 98.8 99.9 99.3 99.676.9 77 77.1 77.2

-8~15-18~52R-134a

204 202 204 220 252 2542

219.1 273

230

EWAD-C-P

CapacityPower input

EWAD C12C-PS

Page 32: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

COOLING ONLYEWAD~C-PR (Reduced noise)

Capacity (Eurovent) Cooling kWNominal input (Eurovent) Cooling kWCapacity Steps % 12.5 - 100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating weight kgWater Heat Exchanger Evaporator

Type Single pass shell and tubeWater volume lNominal water fl ow rate Cooling l/sNominal water pressure drop Cooling kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Nominal air fl ow l/s

Speed rpmCompressor Type Semi-hermetic single screw compressor

Quantity No.Sound level Sound Power Cooling dBA

Sound Pressure Cooling dBAOperation Range Water side Min~Max °CDB

Air side Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

810 880 960 C10 C11 C13 C14

809 875 956 1,053 1,132 1,251 1,359219 244 272 299 330 364 396

3.7 3.58 3.51 3.52 3.43 3.44 3.434.63 4.59 4.54 4.59 4.5 4.53 4.51

2,540 x 2,285 x 8,885 2,540 x 2,285 x 9,785 2,540 x 2,285 x 11,085 2,540 x 2,285 x 11,9857,820 7,950 8,580 8,840 10,380 10,0208,420 8,990 9,620 9,880 10,670 11,010

599 1,043 1,027 995 97938.65 41.81 45.69 50.30 54.11 59.76 64.95

56 63 29 59 66 58 70

73,811 82,012 90,213 98,414715

292.7 93.4 93.8 94.1 94.471.2 71.7 72

-8~15-18~52R-134a

204 202 204 220 252 2542

219.1 273

231

CapacityPower input

Page 33: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled

› Daikin scroll compressor

› Optimised for use with R-407C

› Electronic DDC controller

› Low operating sound level

› Low energy consumption

› Extension possible up to 195kW

› Compact dimensions and low refrigerant volume

› Easy installation and maintenance

› Stainless steel plate heat exchanger

› Remote cooling or heating selection

› Water/water heat pump, with water reversibility

› Compatible with hydraulic module

› For EWWP014-065KAW1N following components are standard included:

main switch, pressure ports, flow switch, filter, shut-off valves and air purge

HEATING ONLY & COOLING ONLY

Capacity Cooling kWPower input Cooling kWCapacity StepsEERDimensions Height x Width x Depth mmWeight Machine weight kgWater Heat Exchanger Evaporator

Type Brased plateMinimum water volume in the system lWater flow rate

Min l/minNominal l/minMax l/min

Water Heat Exchanger Condenser

Type Brased plateWater flow rate

Min l/minNominal l/minMax l/min

Compressor Type Hermetically sealed scroll compressorModel Quantity

Sound Power Cooling dBAOperation Range Evaporator Min~Max °C

Condenser Min~Max °CRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Thermostatic expansion valve

Power Supply 3N~/400V/50HzPiping connections Evaporator water inlet/outlet mm FBSP 25 FBSP 40 2 x 2 x FBSP 38 3 x 2 x FBSP 38

Evaporator water drain Field installationCondenser water inlet/outlet mm FBSP 25 FBSP 40 2 x 2 x FBSP 38 3 x 2 x FBSP 38Condenser water drain Field installation

EWWP-KAW1N

014 022 028 035 045 055 065 90 100 110 120 130 145 155 165 175 185 195

13.0 21.5 28.0 32.5 43.0 56.0 65.0 86.0 99.0 112 121 130 142 155 168 177 186 1953.61 5.79 7.48 8.75 11.80 15.50 17.60 23.6 27.3 31.0 33.1 35.2 39.1 42.8 46.5 48.6 50.7 52.8

1 2 4 63.6 3.71 3.74 3.71 3.64 3.61 3.69 3.64 3.63 3.61 3.66 3.69 3.63 3.62 3.61 3.64 3.67 3.69

600 x 600 x 600 600 x 600 x 1,200 1,200 x 600 x 1,200 1,800 x 600 x 1,200118 155 165 172 300 320 334 600 620 640 654 668 920 940 960 974 988 1,002

62 103 134 155 205 268 311 205 268 311 205 268 31119 31 40 47 62 80 93 123 142 161 173 186 204 222 241 254 267 28037 62 80 93 123 161 186 247 284 321 347 373 407 444 482 507 533 55975 123 161 186 247 321 373 493 568 642 694 745 814 889 963 1,015 1,066 1,118

24 39 51 59 79 102 118 157 181 205 221 237 260 283 307 323 339 35548 78 102 118 157 205 237 314 362 410 442 474 519 567 614 647 679 71195 157 203 237 314 410 474 629 724 819 883 948 1,038 1,133 1,229 1,293 1,357 1,422

1 2 4 664 71 67 74 71 75 77 73 76 78 79

-10(OPZL) ~ 2020 ~ 55R-407C

1.2 2 2.5 3.1 4.6 5.6 9.2 10.2 11.2 13.8 14.8 15.8 16.81 2 4 6

232

CAPACITY CLASS

MICRO CHILLER

EWWP014-035KAW1

Page 34: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

EWWP014-035KAW1N

EWWP090-130KAW1N

EWWP145-195KAW1N

233

pCO²

SELECTION TABLE 1 MODULE (KA-SERIES) 2 MODULES (KA-SERIES) 3 MODULES (KA-SERIES)

Capacity index

Cooling capacity (kW)

Heating capacity (kW)

UNIT+

CONTROL(Factory mounted)

EWWP014KAW1NEWWP022KAW1NEWWP028KAW1NEWWP035KAW1NEWWP045KAW1NEWWP055KAW1NEWWP065KAW1N

UNIT ONLY(Without Control)

EWWP045KAW1MEWWP055KAW1MEWWP065KAW1M

CONTROL(Kit)

ECB 1 MUWECB 2 MUWECB 3 MUW

For example: for a 121 kW -HP system, select : EWWP055KAW1 + EWWP065KAW1

014 022 028 035 045 055 065 090 100 110 120 130 145 155 165 175 185 195

13.0 21.5 28.0 32.5 43.0 56.0 65.0 86.0 99.0 112 121 130 142 155 168 177 186 195

16 26.2 35.3 41 52.5 71 81 105 124 142 153 164 176 195 213 224 235 246

1 - - - - - - - - - - - - - - - - -- 1 - - - - - - - - - - - - - - - -- - 1 - - - - - - - - - - - - - - -- - - 1 - - - - - - - - - - - - - -- - - - 1 - - - - - - - - - - - - -- - - - - 1 - - - - - - - - - - - -- - - - - - 1 - - - - - - - - - - -- - - - 1 - - 2 1 - - - 2 1 - - - -- - - - - 1 - - 1 2 1 - 1 2 3 2 1 -- - - - - - 1 - - - 1 2 - - - 1 2 3- - - - 1 1 1 - - - - - - - - - -- - - - - - - 1 1 1 1 1 - - - - - -- - - - - - - - - - - - 1 1 1 1 1 1

Page 35: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled

› All models are PED pressure vessel approved

› Daikin semi-hermetic single screw stepless compressor

› All components optimised for use with R-134a refrigerant

› Advanced pCO² DDC controller

› Moisture indicator as standard

› Victaulic joints as standard

› Low operating sound level - extra low noise option available

› DICN (Daikin Integrated Chiller Network) operation

as standard within same series

› Double refrigeration circuit (from 360kW on)

› Chilled water temperatures down to -10°C on standard unit (parameter in

the service menu of the PCO² digital controller must be set by the installer)

› Modular design

HEATING ONLY & COOLING ONLYCAPACITY CLASS

Capacity Cooling kWHeating kW

Power input Cooling kWHeating kW

Capacity Steps % 30-100 (stepless) 15-100 (stepless)EERCOPDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Brased plate, one per circuitMinimum water volume in the system lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaWater Heat Exchanger Condenser

Type Shell and tubeWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Heating kPaCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power LwA dBAOperation Range Evaporator Min~Max °C

Condenser Min~Max °CRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuits

Refrigerant control Thermostatic expansion valve Electronic expansion valve 2x Thermostatic expansion valve

1x Thermostatic expansion valve 2x Electronic expansion valve 2 x Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet 3" OD victaulic coupling 3" victaulic coupling

Evaporator water drain Field installationCondenser water inlet/outlet 2'' 1/2 victaulic 3'' victaulicRelief device outlet 1x1'' 2x1'' 3x1'' 4x1''

120 180 240 280 360 440 500 520 540

123 183 249 273 366 432 498 522 546147 216 290 327 431 505 580 617 65528.7 45.2 61.6 69.2 90.5 107 123 131 13834.5 54 72.8 83.4 108 127 146 156 167

4.29 4.05 4.04 3.95 4.04 4.05 3.98 3.964.26 4.00 3.98 3.92 3.99 3.98 3.97 3.96 3.92

1,018 x 2,681 (3,051) x 930 1,018 x 2,681 (3,254) x 930 2,000 x 2,681 (3,254) x 9301,000 1,273 1,527 1,623 2,546 2,800 3,034 3,150 3,3461,032 1,318 1,588 1,693 2,636 2,906 3,156 3,281 3,485

600 890 1,220 1,330 895 1,055 1,215 1,275 1,335175 265 350 400 525 625 700 750 800353 525 714 783 1,049 1,238 1,428 1,496 1,565700 1,070 1,400 1,600 2,100 2,500 2,800 3,000 3,200

21 + 2 + 23 25 + 3 + 28 26 + 7 + 33 22 + 9 + 31 2x (25 + 3 + 28) 25 + 3 + 28 + 26 + 7 + 33 2x (26 + 7 + 33 ) 26 + 7 + 33 + 22 + 9 + 31 2x (22 + 9 + 31)

217 336 450 520 670 790 900 970 1,040435 654 890 981 1,309 1,545 1,781 1,871 1,962800 1,050 1,230 1,370 2,100 2,290 2,470 2,600 2,73025 30 38 30 + 30 30 + 38 38 + 38

1 287 93 94 93 96

- 10 ~ 2010 ~ 50 20 ~ 60 20 ~ 50 20 ~ 60

R-134a18 35 37 38 70 72 74 75 76

1 2

234

EWWD-MBYN

pCO2

EWWD540MBYN

Page 36: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled - Standard Efficiency

› All models are PED pressure vessel approved

› Stepless single-screw compressor

› Optimised for use with R-134a

› Cooling range: 165.5-555.7kW

› EER range up to 4

› 1-2 truly independent refrigerant circuits

› Standard electronic expansion valve

› DX shell and tube evaporator – one pass refrigerant

side for easy oil circulation and return

› Partial and total heat recovery option available

HEATING ONLY & COOLING ONLYCAPACITY CLASS

Capacity Cooling kWHeating kW

Power input Cooling kWCapacity Steps % 25-100 (stepless) 12.5-100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaWater Heat Exchanger Condenser

Type Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Heating kPaCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Pressure Cooling dBAOperation Range Evaporator Min~Max °CDB

Condenser Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water drain 1/2'' gas

170 210 260 300 320 380 420 460 500 600

165.5 201.2 252.8 280.4 333.9 372.2 402.5 448.3 493.7 555.7207.6 251.9 317.7 355.7 418.2 465.3 503.9 563.4 622.7 705.542.1 50.7 64.9 75.4 84.3 93.1 101.4 115.1 129.0 150.2

3.93 3.97 3.90 3.72 3.96 4.00 3.97 3.89 3.83 3.705.00 5.04 4.95 4.72 5.28 5.33 5.29 5.19 5.10 4.93

1,860 x 920 x 3,435 1,880 x 860 x 4,3051,393 1,410 1,503 2,687 2,697 2,702 2,757 2,7621,470 1,480 1,650 2,840 2,850 2,860 2,970

60 56 123 118 113 173 168218 220 349 380 425 430 553 612 613474 577 725 804 957 1,067 1,154 1,285 1,415 1,593688 694 1,105 1,104 1,201 1,344 1,360 1,749 1,935 1,93947.5 69 43 53 63.5 63 72 54 53.5 67.5

13 15 26 28 30303 357 363 368 603 659 718 726 729 741595 722 911 1,020 1,199 1,334 1,445 1,615 1,785 2,024959 1,128 1,147 1,162 1,908 2,083 2,270 2,296 2,305 2,34438.5 41 63 77 39.5 41 40.5 49.5 60 74.5

1 269.7 71.7

-8 ~ 1525 ~ 40R-134a

50 1001 2

235

EWWD-DJYNN

pCO2

EWWD260DJYNN

Page 37: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled - High Efficiency

› High efficiency

› All models are PED pressure vessel approved

› Stepless single-screw compressor

› Optimised for use with R-134a

› Cooling range: 186.4-603.9kW

› EER range up to 4.73

› 1-2 truly independent refrigerant circuits

› Standard electronic expansion valve

› DX shell and tube evaporator – one pass refrigerant

side for easy oil circulation and return

› Partial and total heat recovery option available

HEATING ONLY & COOLING ONLYCAPACITY CLASS

Capacity Cooling kWHeating kW

Power input Cooling kWCapacity Steps % 25-100 (stepless) 12.5-100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaWater Heat Exchanger Condenser

Type Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Heating kPaCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Pressure Cooling dBAOperation Range Evaporator Min~Max °C

Condenser Min~Max °CRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50Hz

190 230 280 320 380 400 460 500 550 650

186.4 223.3 276.5 306.7 366.3 408.2 443.6 496.0 540.5 603.9226.1 271.4 335.8 378.1 445.6 495.4 538.6 600.8 654.9 741.639.7 48.1 59.3 71.4 79.3 87.2 95.0 104.8 114.4 137.7

4.70 4.64 4.66 4.30 4.62 4.68 4.67 4.73 4.72 4.395.97 5.90 5.92 5.46 6.15 6.24 6.23 6.31 6.30 5.85

1,860 x 920 x 3,435 1,880 x 860 x 4,3051,650 1,665 1,680 2,800 2,945 2,955 2,975 2,9901,800 1,810 1,820 3,020 3,280 3,290 3,315 3,340

125 120 110 170 285 280341 342 424 419 606 763 760 720 726 725534 640 793 879 1,050 1,170 1,272 1,422 1,549 1,731

1,080 1,082 1,340 1,325 1,917 2,414 2,403 2,277 2,297 2,29324.5 35 44 30 23.5 28 39 45.5 57

22 25 44 47 50 59 68497 550 609 648 994 1,089 1,202 1,362 1,533 1,542648 778 963 1,084 1,277 1,420 1,544 1,722 1,877 2,126

1,572 1,740 1,925 2,048 3,145 3,444 3,801 4,306 4,847 4,87717 20 25 28 16.5 17 16.5 16 15 19

1 269.7 71.7

-8 ~ 1525 ~ 40R-134a

50 1001 2

236

EWWD-DJYNN/A

pCO2

EWWD650DJYNN/A

Page 38: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled

› All models are PED pressure vessel approved

› Stepless single-screw compressor

› Optimised for use with R-134a

› Cooling range: 333-1,510 kW

› EER range: 4.28-4.66

› 1-2-3 truly independent refrigerant circuits

› Standard electronic expansion valve

› DX shell and tube evaporator – one pass

refrigerant side to minimize pressure drops

› Partial and total heat recovery option available

HEATING ONLY & COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Shell and tubeWater volume lWater fl ow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaWater Heat Exchanger Condenser

Type Shell and tubeWater volume lWater fl ow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPa

Compressor Type Screw compressorModel Quantity

Sound Power Cooling dBAOperation Range Evaporator Min~Max °C -8 (OPZL) ~ 15

Condenser Min~Max °CRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve -

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

Condensor water inlet/outlet

340 400 460 550 650 700 800 850 900 950 C10 C12 C13 C14 C15 C16 C17 C18

333 394 460 538 640 705 782 844 910 986 1,027 1,155 1,204 1,274 1,346 1,401 1,455 1,51071.45 85.84 100.86 120.36 141.34 155.85 171.32 185.55 200.01 218.45 236.91 254.34 267.70 282.46 298.23 316.48 334.72 352.964.66 4.59 4.56 4.47 4.53 4.52 4.56 4.55 4.51 4.33 4.54 4.50 4.51 4.51 4.43 4.35 4.28

1,983 x 1,430 x 3,533 2,245 x 1,350 x 4,769 2,398 x 2,153 x 4,4702,640 2,745 2,772 5,056 5,121 5,205 5,219 5,233 5,268 6,079 6,097 6,136 6,174 6,192 6,210 6,2285,051 5,203 5,244 9,543 9,623 9,730 9,754 9,779 9,826 6,718 6,744 6,776 6,805 6,831 6,856 6,883

1,058 1,263 1,478 1,729 868 957 1,088 1,144 1,204 1,346 1,356 718 754 793 832 871 909 948179.4 214.2 250.5 293.1 356.9 393.2 447.3 470.2 494.7 553.3 557.5 651.2 684 719.1 755.3 790.2 825.1 860954.1 1,128.7 1,318.1 1,542.6 1,834.6 2,019.8 2,242.3 2,420.6 2,609.2 2,827.4 2,943.9 3,312.1 3,451.6 3,652.1 3,859.2 4,015.7 4,172.2 4,328.8

1,614.6 1,898.8 2,214.4 2,587.7 3,021.1 3,320.3 3,687.3 3,994 4,233.4 4,642.1 4,701.7 5,368.5 5,581.7 5,965.6 6,344.2 6,588.5 6,832.8 7,077.137.02 50.09 53.74 61.91 55.15 44.15 58.38 53.42 53.15 66.29 51.25 51.73 55.72 44.69 57.68 61.96 66.37 70.92

1,871 2,199 2,568 2,864 1,538 1,676 1,855 1,977 2,102 2,257 2,278 1,237 1,303 1,372 1,440 1,486 1,533 1,579317 372.3 435.8 484.8 632.2 688.9 762.6 812.6 864.1 927.9 936.4 1,122.5 1,182.3 1,244.5 1,306.2 1,348.5 1,390.7 1,433

1,158.9 1,374.8 1,607.2 1,887.6 2,239.8 2,466.5 2,733.4 2,952.5 3,182.6 3,453.6 3,623 4,041.2 4,219 4,461.9 4,714.1 4,922.9 5,131.8 5,340.61,868.3 2,207 2,576.6 3,017.3 3,516.5 3,870.2 4,296.6 4,654.2 4,940.1 5,416.2 5,532.1 6,265.4 6,523.5 6,963.4 7,401.7 7,709.2 8,016.7 8,324.2

26.35 27.95 29.76 25.65 24.78 + 24.78

25.41 + 26.37

27.65 + 27.65

28.04 + 25.97

26.45 + 26.45

22.66 + 24.04

23.82 + 23.82 3x 24.08 2x 24.08+

22.2824.55 + 2x 22.95 3x 23.86 2x 23.86 +

23.0923.86 + 2x 23.09 3x23.09

1 2 393.6 94.6 96.6 96.9 97.3 97.8 98.9 99.8 98.3 98.6 100.6 101.2 101.8

15~55R-134a

54 52 108 106 104 1561 2 3

168.30 219.105"

237

EWWD-EJYNN

pCO2

EWWD-EJYNN

Page 39: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled - High Efficiency

› High efficiency

› All models are PED pressure vessel approved

› Stepless single-screw compressor

› Optimised for use with R-134a

› Cooling range: 362-1,134 kW

› EER range: 4.72-5.12

› 1 or 2 truly independent refrigerant circuits

› Standard electronic expansion valve

› DX shell and tube evaporator – one pass

refrigerant side to minimize pressure drops

HEATING ONLY & COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaWater Heat Exchanger Condenser

Type Shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaCompressor Type Screw compressor

Model QuantitySound Power Cooling dBAOperation Range Evaporator Min~Max °C -8 (OPZL) ~ 15

Condenser Min~Max °CRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

Condensor water inlet/outlet

360 440 500 600 750 800 850 950 C10 C11 C12

362 433 506 573 720 795 866 933 976 1,038 1,13470.68 85.32 100.09 120.35 141.56 155.84 170.45 184.75 199.04 219.92 239.925.12 5.08 5.06 4.76 5.09 5.1 5.08 5.05 4.9 4.72 4.73

1,983 x 1,430 x 3,533 2,245 x 1,350 x 4,7692,640 2,745 2,772 5,056 5,121 5,205 5,219 5,233 5,2685,051 5,203 5,244 9,543 9,623 9,730 9,754 9,779 9,826

1,127 1,350 1,582 1,801 948 1,052 1,146 1,240 1,301 1,382 1,515191.1 229 268.2 305.3 389.8 432.6 471 509.7 534.9 567.9 622.8

1,036.6 1,241.5 1,451.2 1,642.6 2,063.2 2,278.4 2,483.4 2,676 2,797.6 2,975.2 3,249.82,280.1 2,720.9 3,170.1 3,559.6 4,479.1 4,925.7 5,368.3 5,762.2 6,003.3 6,395.9 6,960.6

64 48 54 68 58 68 56 64 72 46 52

1,923 2,262 2,653 2,938 1,604 1,758 1,901 2,060 2,187 2,295 2,457326.1 384.2 450 497.7 659.3 722.5 781.4 846.9 898.8 943.5 1,010

1,239.2 1,486.1 1,738.1 1,987.6 1,234.8 1,498.8 1,485 1,708.8 1,684.2 1,987.2 1,969.22,034.8 2,432.7 2,836.1 3,206.3 3,996.8 4,396.3 4,797.9 5,150.9 5,384.9 5,766.7 6,270.747.67 47.19 51.37 66.03 48.07 46.92 49.83 64.97

1 293.6 94.6 96.6 96.9 97.3 97.8 98.9 99.8 98.3 98.6

15~55R-134a

54 52 108 106 1041 2

168.30 219.104''

238

EWWD-EJYNN/A

pCO2

EWWD-EJYNN/A

Page 40: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled

› Cooling range: 369–1,050kW

› Super high efficiency: EER up to 5.84

› Very high EER values at part loads condition (ESEER up to 7.4)

› 1 and 2 stepless single-screw compressors

› Optimised for use with R-134a

› Flooded evaporator

› Expansion valve with liquid level control

› All models are PED pressure vessel approved

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 25-100 (stepless) 12.5-100 (stepless)EERESEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Flooded shell and tubeWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaWater Heat Exchanger Condenser

Water volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Heating kPaCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Pressure Cooling dBAOperation Range Evaporator Min~Max °CDB

Condenser Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water drain 1/2'' gas

380 460 550 750 850 900 C10 C11

369 445 521 734 816 895 976 1,05065 77.9 90 129 142 155 167 180

5.68 5.71 5.79 5.69 5.75 5.77 5.84 5.836.44 6.47 6.56 7.16 7.23 7.32 7.37 7.40

2,250 x 3,625 x 1,551 2,250 x 3,860 x 1,551 2,300 x 4,145 x 1,743 2,300 x 4,145 x 1,808 2,300 x 4,145 x 1,9103,089 3,370 3,603 5,546 5,636 6,007 6,448 6,5983,250 3,588 3,870 5,911 6,045 6,460 6,972 7,163

78 107 134 184 210 281 302565 615 776 932 1,216 1,209 1,382 1,632

1,058 1,276 1,494 2,104 2,339 2,566 2,798 3,0101,788 1,945 2,455 2,946 3,846 3,825 4,370 5,162

35 43 37 51 37 45 41 3483 111 133 181 199 243 263

665 948 1,086 1,478 1,703 1,904 1,924 2,1461,244 1,499 1,752 2,474 2,746 3,010 3,277 3,5262,103 2,998 3,435 4,675 5,386 6,020 6,085 6,786

35 25 26 28 26 25 29 27

1 278 79 80 81 81.5 82 82.5 83

-8 ~ 1521 ~ 50R-134a

130 165 180 200 215 230 274 2901

239

EWWD-BJYNN

pCO²

EWWDC11BJYNN

Page 41: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled - Standard Efficiency

› All models are PED pressure vessel approved

› Cooling range: 388-2,093kW

› EER range up to 4.64

› ESEER up to 5.37

› 1 or 2 stepless single-screw compressors

› 1 or 2 truly independent refrigerant circuits

› Shell and tube heat exchanger

› Optimised for use with R-410A

› Standard electronic expansion valve

› Compact design

› Partial heat recovery available

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWNominal input Cooling kW

Capacity Steps % 25-100 (stepless) 12.5-100 (stepless)

25-100 (stepless) 12.5-100 (stepless) 25-100

(stepless) 12.5-100 (stepless)

EERESEER

Dimensions Height x Width x Depth mm

Weight Machine weight kgOperating Weight kg

Water Heat Exchanger Evaporator

Type Shell and tubeWater volume lWater flow rate

Min l/minMax l/min

Nominal water pressure drop Cooling kPaWater Heat Exchanger Condenser

Type Shell and tubeWater volume lWater volume lWater flow rate

Min l/minMax l/min

Nominal water pressure drop Cooling kPaCompressor Type Semi hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Evaporator Min~Max °CDB

Condenser Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm 168.3 219.1 273.0

Condenser water inlet/outlet 5'' 5" 5'' 6" 5'' 6" 5" 6" 5" 6"

400 480 600 650 750 800 850 900 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20

387.96 474.13 574.36 651.45 742.14 812.53 880.09 891.19 980.45 1,028.15 1,077.43 1,210.09 1,281.09 1,352.09 1,488.14 1,620.34 1,783.43 1,928.13 2,092.7387.37 106.27 130.44 147.86 169.73 175.22 206.4 194.02 212.97 245.47 236.90 261.72 279.05 296.39 339.95 375.37 408.72 441.58 475.47

4.44 4.46 4.40 4.41 4.37 4.64 4.26 4.59 4.6 4.19 4.55 4.62 4.59 4.56 4.38 4.32 4.36 4.37 4.404.95 4.98 4.97 4.72 5.37 4.60 5.36 5.34 4.53 5.33 5.36 5.35 5.29 4.93 4.82 4.89 4.87

1,846 x1,065 x3,431 2,000x1,226 x3,440 1,846 x1,266 x3,561

2,170x1,350 x4,902

1,846x1,266 x3,561 2,170x1,350x4,902 1,846x1,266

x3,5612,379x1,350

x4,912 2,455x1,350x4,835 2,547x1,350x4,844 2,547x1,350 x4,809

1,933 1,967 2,283 2,332 2,407 3,921 2,427 3,949 3,988 2,457 4,344 4,529 4,536 4,607 4,988 4,999 5,053 5,204 5,2892,135 2,169 2,543 2,628 2,777 4,422 2,795 4,463 4,496 2,812 4,780 5,186 5,200 5,280 5,602 5,615 5,670 5,881 5,970

124 118 176 170 274 344 266 344 325 251 325 538 505 495 539 527664 812 986 1,118 1,225 1,385 1,279 1,522 1,673 1,283 1,845 2,062 2,188 2,314 2,391 2,501 2,925 3,267 3,667

1,258 1,354 1,860 2,108 2,415 2,649 2,859 2,898 3,189 3,342 3,492 3,937 4,160 4,383 4,840 5,255 5,785 6,238 6,76849.43 64.65 45.04 47.92 54.74 53.80 50.22 63.54 59.07 57.23 70.01 45.37 50.28 55.40 59.86 69.74 89.42 98.78 122.57

79 92 84 162 97 79 102 79 92 104 52 60 60 68 54 54 61 61 77- 79 - 92 - 60 68 54 57 61 77

813 994 1,210 1,371 1,506 1,683 1,579 1,854 2,037 1,589 2,251 2,508 2,664 2,821 2,937 3,080 3,595 4,015 4,5001,541 1,878 2,282 2,587 2,968 3,220 3,530 3,882 4,139 4,260 4,789 5,066 5,345 5,945 6,472 7,112 7,666 8,30760.15 64.35 67.91 66.02 16.46 64.44 20.43 66.55 67.64 25.92 70.09 73.40 69.77 16.52 19.31 16.93 17.08 15.02

1 2 1 2 1 2100.2 101.2 102.3 101.5 104.7 102.3 104.7 105.1 103.2 104.7 105.2 106.5 105.8 106.2 106.6 107.1 107.5

-4~1025~45R-410A

80 90 100 85+85 100 85+85 100 95+95 100+100 130+1301 2 1 2 1 2

240

EWWQ-AJYNN

pCO2

EWWQ400AJYNN

Page 42: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Water Cooled - High Efficiency

› All models are PED pressure vessel approved

› Cooling range: 431-2,196kW

› EER range up to 5.09

› ESEER up to 5.98

› 1 or 2 stepless single-screw compressors

› 1 or 2 truly independent refrigerant circuits

› Shell and tube heat exchanger

› Optimised for use with R-410A

› Standard electronic expansion valve

› Compact design

› Partial heat recovery available

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kW

Capacity Steps % 25-100 (stepless) 12.5-100 (stepless)

25-100 (stepless) 12.5-100 (stepless)

EERESEER

Dimensions Height x Width x Depth mm

Weight Machine weight kgOperating Weight kg

Water Heat Exchanger Evaporator

Type Shell and tubeWater volume lWater flow rate

Min l/minMax l/min

Nominal water pressure drop Cooling kPaWater Heat Exchanger Condenser

Type Shell and tubeWater volume lWater volume lWater flow rate

Min l/minMax l/min

Nominal water pressure drop Cooling kPaCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Evaporator Min~Max °CDB

Condenser Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm 219.1 273.0

Condenser water inlet/outlet 5'' 5"

440 550 650 750 800 950 C10 C11 C12 C13 C14 C15 C16 C18 C19 C20 C22

431 527 653 740 818 993 1,059 1,139 1,182 1,297 1,397 1,479 1,605 1,769 1,901 2,061 2,19686.67 104.72 128.28 145.95 162.04 196.57 209.49 232.06 233.11 257.54 274.77 291.86 321.48 356.36 390.31 425.94 460.72

4.97 5.03 5.09 5.07 5.05 5.06 4.91 5.07 5.04 5.08 5.07 4.99 4.96 4.87 4.84 4.775.58 5.61 5.69 5.67 5.64 5.39 5.89 5.28 5.87 5.88 5.98 5.93 5.67 5.71 5.48 5.50 5.38

2,000x1,211x3,987 2,001x1,218 x3,855

2,000x1,266 x3,854

2,001x1,448 x3,891

2,453x1,350 x4,985

2,001x1,448 x3,891 2,453x1,350x4,985 2,547x1,350x4,844 2,547x1,350x4,809

2,322 2,403 2,738 2,407 2,427 4,775 2,457 4,831 4,873 4,919 4,969 5,117 5,388 5,408 5,4142,594 2,685 2,745 3,158 2,815 3,056 5,431 3,086 5,479 5,512 5,546 5,606 5,794 5,843 6,110 6,118 6,124

220 213 200 334 325 538 587 538 575 563 551 495 484 535 527733 898 1,114 1,262 1,438 1,733 1,805 1,994 2,016 2,213 2,383 2,523 2,811 3,097 3,334 3,617 3,862

1,407 1,718 2,133 2,419 2,651 3,234 3,462 3,695 3,862 4,237 4,563 4,823 5,219 5,749 6,158 6,671 7,09455.77 68.81 71.54 64.27 57.46 53.85 53.69 68.89 64.23 55.13 67.85 75.14 70.1 89.12 91.3 113.04 126.77

52 69 81 86 83 91 69 91 73 76 75 86 91 91 91 91 91- 70 - 76 86 91

881 1,076 1,332 1,511 1,723 2,076 2,162 2,400 2,414 2,652 2,852 3,021 3,374 3,721 4,019 4,365 4,6721,691 2,060 2,552 2,896 3,176 3,875 4,147 4,447 4,624 5,077 5,461 5,774 6,264 6,908 7,422 8,049 8,58150.16 39.75 42.38 46.94 59.79 64.73 40.10 83.56 47.93 48.17 49.20 46.82 44.26 61.21 60.50 79.00

1 2 1 2100.9 101.7 102.6 102.7 102.0 102.9 105.2 103.8 105.6 106.1 106.5 105.8 106.2 106.6 107.1 107.5

-4~1025~45R-410A

95 110 130 120+120 130 120+120 130+1301 2 1 2

241

EWWQ-AJYNN/A

pCO2

EWWQC22AJYNN/A

Page 43: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Condenserless Chiller

› Daikin scroll compressor

› Optimised for use with R-407C

› Electronic DDC controller

› Low operating sound level

› Low energy consumption

› Compact dimensions and low refrigerant volume

› Easy installation and maintenance

› Stainless steel plate heat exchanger

› Compatible with hydraulic module

› For EWLP012-065KAW1N following components are standard included:

main switch, pressure ports, flow switch, filter, shut-off valves and air purge

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity StepsEERDimensions Height x Width x Depth mmWeight Machine weight kgWater Heat Exchanger Evaporator

Type Brased plateMinimum water volume in the system lWater flow rate

Min l/minNominal l/minMax l/min

Compressor Type Hermetically sealed scroll compressorModel Quantity

Sound Power Cooling dBAOperation Range Evaporator Min~Max °CDB

Condensing temperature Min~Max °CDBRefrigerant circuit Refrigerant type

No of circuitsRefrigerant control Thermostatic expansion valve

Power Supply 3N~/400V/50HzPiping connections Evaporator water inlet/outlet mm FBSP 25 FBSP 40

Evaporator water drain Field installationLiquid line connection mm 9.52 flare 12.7 flare 2x12.7 flareDischarge line connection mm 12.7 flare 19.1 flare 2x19.1 flare

012 020 026 030 040 055 065

12.1 20.0 26.8 31.2 40.0 53.7 62.44.2 6.6 8.5 10.1 13.4 17.8 20.3

1 22.88 3.03 3.15 3.09 2.99 3.02 3.07

600 x 600 x 600 600 x 600 x 1,200108 141 147 151 252 265 274

62 103 134 155 205 268 31117 29 38 45 57 77 8935 57 77 89 115 154 17969 115 153 179 229 307 358

1 264 71 67 74

-10(OPZL) ~ 2025 ~ 60R-407C

1 2

242

EWLP-KAW1N

MICRO CHILLER

EWLP014KAW1N

Page 44: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Condenserless Chiller

› All models are PED pressure vessel approved

› Daikin semi-hermetic single screw stepless compressor

› All components optimised for use with R-134a refrigerant

› Advanced pCO² DDC controller

› Moisture indicator as standard

› Victaulic joints as standard

› Low operating sound level - extra low noise option available

› DICN (Daikin Integrated Chiller Network) operation

as standard within same series

› Double refrigeration circuit (from 340kW on)

› Chilled water temperatures down to -10°C on standard unit (parameter in

the service menu of the PCO² digital controller must be set by the installer)

› Modular design

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 30-100 (stepless) 15-100 (stepless)EERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Brased plate, one per circuitWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Evaporator Min~Max °CDB

Condensing temperature Min~Max °CDBRefrigerant circuit Refrigerant type

No of circuitsRefrigerant control Thermostatic expansion valve Electronic expansion valve 2x Thermostatic

expansion valve1x Thermostatic expansion valve

1x Electronic expansion valve 2x Thermostatic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet 3'' OD victaulic coupling 3'' victaulic coupling

Evaporator water drain Field installationLiquid line connection 7/8'' 1'' 1/8 1'' 3/8 2x1/8'' 1''1/8 + 1''3/8 2x1'' 3/8Discharge line connection 2'' 1/8 2'' 5/8 2x(2''1/8) 2'' 1/8 + 2'' 5/8 2x(2''5/8)

120 170 240 260 340 400 480 500 540

116 170 235 265 340 405 470 500 53032.0 49.8 66.5 77.9 99.6 116 133 144 156

3.63 3.41 3.53 3.40 3.41 3.49 3.53 3.47 3.41,018 x 2,681 (3,051) x 930 1,018 x 2,681 (3,254) x 930 2,000 x 2,681 (3,254) x 930

891 1,110 1,342 1,428 2,220 2,452 2,684 2,770 2,856907 1,130 1,369 1,462 2,260 2,497 2,738 2,831 2,924

570 830 1,150 1,300 830 990 1,150 1,220 1,295175 265 350 400 525 625 700 750 800333 487 674 760 975 1,161 1,347 1,434 1,520700 1,070 1,400 1,600 2,100 2,500 2,800 3,000 3,200

21 + 2 + 23 25 + 3 + 28 26 + 6 + 32 22 + 8 + 30 2x (25 + 3 + 28 ) 25 + 3 + 28 + 26 + 7 + 33 2x (26 + 7 + 33) 26 + 7 + 33 + 22 + 9 + 31 2x (22 + 9 + 31 )

1 287 93 94 93 96

-10 ~ 2025-55 25 ~ 62 25 ~ 55 25 ~ 62

R-134a1 2

243

EWLD-MBYN

pCO²

EWLD120MBYN

Page 45: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Condenserless Chiller

› Cooling range: 161 - 526 kW

› 1-2 truly independent refrigerant circuits

› Optimised for use with R-134a

› Stepless single-screw compressor

› All models are PED pressure vessel approved

› DX shell and tube evaporator – one pass refrigerant

side for easy oil circulation and return

› Electronic expansion device as standard

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWCapacity Steps % 25-100 (stepless) 12.5-100 (stepless)EERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Shell and tube - direct expansionWater volume lWater flow rate

Min l/minNominal l/minMax l/min

Nominal water pressure drop Cooling kPaCompressor Type Semi-hermetic single screw compressor

Model QuantitySound Power Cooling dBAOperation Range Evaporator Min~Max °CDB

Condensing temperature Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm 88.9 114.3 139.7

160 190 240 280 320 360 380 420 480 550

160.6 189.0 244.0 270.4 315.5 352.2 381.1 428.3 475.7 525.945.4 54.3 65.9 74.6 90.6 99.7 108.6 120 131.5 148

3.54 3.48 3.7 3.62 3.48 3.53 3.51 3.57 3.62 3.551,860 x 1,000 x 3,700 1,942 x 1,100 x 4,400

1,280 1,398 2,442 2,446 2,501 2,5061,337 1,516 2,560 2,670

1,151 1,354 1,749 1,938 1,130 1,262 1,365 1,535 1,704 1,884230.20 270.90 349.74 387.58 452.22 504.83 546.25 613.90 681.84 753.80460.39 541.81 699.47 775.16 904.44 1,009.65 1,092.50 1,227.81 1,363.69 1,507.60649.15 763.95 986.26 1,092.97 1,275.27 1,423.61 1,540.42 1,731.21 1,922.80 2,125.71

48 69 43 53 64 63 72 54 68

1 288 90.5

-8 ~ 1525 ~ 50R-134a

5 101 2

244

EWLD-DJYNN

��!�

Page 46: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Condenserless Chiller

› Cooling range: 328-1,422kW

› EER range: 3.51-3.91

› Stepless single-screw compressor

› Optimised for use with R-134a

› 1 or 2 truly independent refrigerant circuits

› Standard electronic expansion valve

› DX shell and tube evaporator – one pass refrigerant

side for easy oil circulation and return

› All models are PED pressure vessel approved

COOLING ONLYCAPACITY CLASS

Capacity Cooling kWPower input Cooling kWEERDimensions Height x Width x Depth mmWeight Machine weight kg

Operating Weight kgWater Heat Exchanger Evaporator

Type Shell and tubeWater flow rate Nominal l/minNominal water pressure drop Cooling kPa

Compressor Type Screw compressorModel Quantity

Sound Power Cooling dBAOperation Range Evaporator Min~Max °CDB -8 (OPZL) ~ 15

Condensing temperature Min~Max °CDBRefrigerant circuit Refrigerant type

Refrigerant charge kgNo of circuitsRefrigerant control Electronic expansion valve

Power Supply 3~/400V/50HzPiping connections Evaporator water inlet/outlet mm

320 400 420 500 600 650 750 800 850 900 950 C10 C11 C12 C13 C14 C15 C16 C17

328 391 428 504 596 657 730 788 850 919 966 1,003 1,078 1,125 1,188 1,267 1,319 1,370 1,42283.8 100 116 137 165 181 198 214 231 252 271 279 296 312 329 347 366 386 405

3.91 3.69 3.68 3.61 3.63 3.69 3.68 3.65 3.56 3.59 3.64 3.60 3.61 3.65 3.60 3.55 3.511,921 x 1,461 x 3,338 2,113 x 1,350 x 4,332 2,398 x 2,153 x 4,4701,861 1,869 1,884 3,331 3,339 3,347 3,356 3,364 3,412 5,146 5,167 5,188 5,2082,054 2,052 2,056 3,602 3,603 3,604 3,605 3,645 5,667 5,671 5,677 5,680

939 1,119.8 1,227.6 1,445.6 1,709.6 1,884.1 2,093 2,258.3 2,436.5 2,634 2,768.2 2,874.6 3,090.3 3,223.9 3,407 3,631.7 3,780.2 3,928.8 4,077.433.7 46.27 47.28 54.12 48.57 38.96 51.57 47.15 46.98 58.35 45.07 52.23 45.67 49.28 41.21 50.8 54.6 58.53 62.57

1 2 393.6 94.6 96.6 96.9 97.3 97.8 98.8 99.8 98.3 98.6 99.8 100.6 101.2 101.8

-R-134a

51 2 3

168.30 219.10

245

EWLD-EJYNN

��!�

Page 47: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

246

› Single compressor unit up to 4.5MW › Dual compressor unit on single circuit up to 9MW › Optional variable speed drives (VFD) for superior partload performance › Compressor unloading down to 5% for dual compressor units and 10% for single

compressor units without hot gas bypass › Control flexibility for easy integration into BMS

WIDE CHOICE OF CAPACITIES AND EFFICIENCIES

Single compressor

› DWSC: 300 kW - 4,500 kW - Approximately 1.1 million possible chiller offerings with combination options of motors, impellers, gears and vessels

Dual compressor

› DWDC: 600 kW - 9,000 kW - Approximately 0.75 million possible chiller offerings with

combination options of motors, impellers, gears and vessels

VARIABLE FREQUENCY DRIVE OPTION (VFD)

› Inverter technology greatly improving part load efficiency › Reducing annual energy costs

HIGH EFFICIENCY

› COP up to 7 at full load › COP up to 12 at partial load (when coupled with inverter VFD)

POWER LOSS DAMAGE PROTECTION

Power failures do not allow chillers to proceed through their normal shutdown sequence. Poor lubrication at this point can damage the bearings and reduce compressor life. The

compressors are equipped with a lubricant reservoir and a piston with a compressed spring that provides pressurized lubricant to the bearings during the coast-down period. Also, the compressors decelerate quickly due to the low inertia.

Piston

Lubricant reservoir

REFRIGERANT STORAGE CAPABILITY

The condensers are sized to hold the entire chiller refrigerant charge and are provided with the necessary valves to isolate this charge. This feature eliminates the need for separate storage vessels in most applications.

DWSC / DWDC DAIKIN WATER COOLED CHILLERS WITH CENTRIFUGAL COMPRESSORS

Page 48: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

247

D D D D

UNMATCHED UNLOADING

Unloading to 10% of full load for a DWSC single compressor chiller and 5% for a DWDC dual compressor unit, without using inefficient hot gas bypass. This unloading capability provides improved stability of the chilled water temperature and less harmful cycling of compressors.Movable discharge diffuser increases stability and reduces vibrations.

Moveable diffuser closing off impeller discharge area

LOW OPERATIONAL SOUND LEVEL

Liquid Injection

A small amount of liquid refrigerant is taken from the condenser and injected into the compressor discharge area. The liquid droplets absorb sound energy and reduce the compressor's overall operational sound level. The droplets evaporate and reduce discharge superheat.

Quieter as chiller unloads

Daikin’s design results in a reduction in sound levels at lower loads, where most chillers spend most of their operating hours.

ONE DWDC DUAL COMPRESSOR CHILLER VERSUS TWO SINGLE COMPRESSOR

CHILLERS

› Lower equipment costs than two separate chillers › Lower installation cost than two separate chillers › Lower annual operating cost than either one large or two small chillers › Less equipment room space required than for two separate chillers

(smaller footprint) › Capacity reduction to 5% of design value › Standby redundancy for most of the cooling season options of motors, impellers, gears

and vessels

EXCELLENT PART LOAD EFFICIENCY

When one compressor is running, it is able to utilize the heat transfer area of the entire chiller, twice the amount found on a single compressor chiller. This huge amount of surface provides exceptional part load efficiency. The addition of VFDs to the dual compressor chiller produces a very high ARI certified Integrated Part Load Value (IPLV).

PARTIAL LOADS EFFICIENCY FOR 2,000 kW CENTRIFUGAL UNIT

DWSC: single compressorDWDC: double compressorVFD: compressor inverterSpecific selections can vary up or down from this example.

10.0

9.0

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.07.0 7.4 9.7 10.0

Page 49: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Daikin Integrated Chiller Network

APPLICABLE SERIES:

› EWAQ080-260DAYN (R-410A)

› EWYQ080-250DAYN (R-410A)

› EWAP110-540MBYN (R-407C)

› EWTP110-540MBYN (R-407C)

› EWAD120-340MBYN (R-134a)

› EWWD120-540MBYN (R-134a)

› EWLD120-540MBYN (R-134a)

Daikin chillers can be equipped with DICN which allows the simultaneous operation of up to 4 chillers as if they were a

single unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control and is

also useful for back up purposes, ensuring that the necessary amount of cooling is available and guaranteeing reliable

operation of the chiller plant.

This function enables a Daikin 2MW chiller plant to be operated via a single controller.

Please note that DICN is only possible within the same series.

248

D.I.C.N.

Page 50: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Hydraulic Module

› 3 models available

› 100 l tank for all sizes

› freeze up protection

› high static pump (option)

› standard drain kit (for indoor use)

› standard dual pressure ports (before & behind the pump)

HYDRAULIC MODULEEHMC-AV

Nominal flow l/minNominal static height mH

2O

Nominal input WDimensions (HxWxD) mmMachine weight kgSound power dBASound pressure dBAPower supply V1 1~/230V/50HzOperation range Water side °C

Air side °CDBPiping connections Evaporator water inlet/outlet

Drain connection

BUFFER TANK

Water flow

mH2O

55

50

45

40

35

30

25

20

15

10

5

00 20 40 60 80 100 120 140 160 180 200 220 240 260 WF (l/min)

LEGENDS

Pump characteristics1. EHMC30AV10802. EHMC10AV1080 &

EHMC15AV10803. EHMC30AV10104. EHMC10AV1010 &

EHMC15AV1010

Hydraulic module + filter pressures losses5. EHMC15/30AV1010 &

EHMC15/30AV10806. EHMC10AV1010 &

EHMC10AV1080

MODEL Description Volume Dimensions Unit weight

EKBT Buffer tank with cabinet 200l 1,284x637x754 86,5

EKBT500N Buffer tank 500l 710x1,670 70

EKBTC10N Buffer tank 1,000l 860x2,020 100

EKBT500C Buffer tank with cabinet 500l 1,200x1,200x1,950 160

EKBTC10C Buffer tank with casing 1,000l 1,200x1,450x1,950 185

10 15 30

1010 1080 1010 1080 1010 1080

62 88 18717 34 15 27 10 27

630 1,050 650 1,070 1,070 2,0901,284x635x688 1,284x635x688 1,284x635x688

99 101 102 104 105 11163 63 6352 52 52

-10°C ~ 55°C-10°C ~ 43°C

1" BSPF 2" BSPF 2-1/2" BSPF1/2"

249

EHMC

EHMC10-15-30AV1010

Page 51: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a
Page 52: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

251

�� ��YRZ�\ RSXFWB 253FWB-J 254FWD 255FWV 256FWT 257FWM 258FWL 259FWC 260FWF 261

Page 53: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Concealed Ceiling Unit

› Height of the units only 240mm for all the sizes

› 3, 4 or 6 stage row cooling coil

› Drain pan to collect the condensate from: heat

exchanger and regulating valves

› 7-speed electrical motors (with thermal protection on windings)

› All 7 speeds pre-wired in the factory in the terminal block of the switch box

› Standard air filter: removable from the bottom

› Electronic controller with water probe, available in

standard, advanced and advanced plus version

FWB

2-PIPE

Power input High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kWHeating (4-pipe)* High kW

Dimensions Height x Width x Depth mmMachine weight kgSound level Sound power High dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/h

Available pressure High PaStandard heat exchanger Water volume lWater connections Std. heat exchanger inchCurrent input High APower supply 1~/230V/50Hz

* Heating module available as option

�� �� �� �� � � �� �� ��106 192 294

2.61 3.14 3.49 5.08 5.45 6.47 7.57 8.67 10.341.88 2.16 2.34 3.6 3.87 4.4 5.23 5.96 6.95.47 6.01 6.47 10.31 11.39 12.28 15.05 16.85 18.78

3.14 5.99 12.8239x1,039x609 239x1,389x609 239x1,739x609

23 24 26 31 33 35 43 45 4858 60 69

448 539 598 873 936 1,111 1,299 1,488 1,774480 527 567 904 999 1,077 1,319 1,479 1,647

8 14 11 15 8 14 21 267 10 8 12 7 10 16 15 18

400 800 1,20071 65 59

1.1 1.5 2.2 1.6 2.1 3.2 2.1 2.8 4.23/4

0.51 0.94 1.28

252

FWB

FWEC1A FWEC2AFWEC3A

FWB04AAT

Page 54: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Concealed Ceiling Unit

› Wide operating range

› Quiet operation via enlarged fan wheels

› Easy maintenance: filter can be removed from both sides

and beneath (maximum filter size is 400mm)

› Flexibility (2-pipe or 4-pipe)

› 4 speed fan motor (3 selectable)

› Direct driven centrifugal fans

› Flexibility via interchangeable water connection side

› High power air flow

› Slim and compact aesthetic design

› Available static pressure of 30 Pa

› Extended drain pan as standard

› Filter as standard

› Plenum as standard

› Insulated with self-extinguishing class 1 heat insulation

FWB-J

2-PIPE 4-PIPE

Power input High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kWHeating (4-pipe) High kW

Dimensions Height x Width x Depth mm

Machine weight kgSound level Sound power High dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/h

Available pressure High PaStandard heat exchanger Water volume lWater connections Std. heat exchanger inchCurrent input High APower supply 1~/220-240V/50Hz

�� �� �� �� � � �� �� �� �� �� �� �� � � �� ��

34 53 57 54 86 121 117 134 164 166 34 51 54 84 117 137 1631.64 2.67 2.99 3.34 4.81 5.31 6.16 7.26 8.49 8.99 1.67 2.67 3.03 4.88 5.33 6.53 8.210.94 1.88 1.95 2.07 3.40 4.15 4.39 5.06 6.37 6.41 0.97 1.83 1.93 3.41 4.01 4.91 6.282.16 3.62 3.97 4.11 6.30 7.47 8.09 9.64 11.57 11.71 2.12 3.69 3.87 6.40 7.52 9.01 11.09

- 2.49 3.92 4.43 6.70 8.16 9.56 11.68

251 x 814 x 590

251 x 984 x 590 251 x 1,114 x 590 251 x 1,314

x 590 251 x 1,564 x 590 251 x 1,664 x 590 251 x 1,924 x 590 251 x 814

x 590251 x 984

x 590251 x 1,114

x 590251 x 1,314

x 590251 x 1,564

x 590251 x 1,664

x 590251 x 1,924

x 590

20.0 23.0 28.0 31.0 33.0 44.0 48.0 52.0 50.0 56.0 22.0 27.0 31.0 36.0 48.0 52 5647.5 52 49 50 52 55 55.5 56 47 52 50 52 55 56386 549 739 803 1,022 1,109 1,338 1,523 1,764 1,910 386 530 724 986 1,138 1,296 1,660386 549 738 802 1,020 1,107 1,336 1,524 1,764 1,911 387 530 725 985 1,139 1,299 1,660

10.91 8.34 15.64 11.22 31.31 12.56 7.62 9.83 21.71 16.81 10.95 8.24 15.67 29.95 9.24 12.49 19.388.86 6.76 12.84 9.21 25.87 11.13 6.57 8.60 18.56 14.46 8.94 6.64 12.84 24.16 7.89 9.76 16.50262 428 431 428 757 945 950 1,066 1,463 1,341 220 424 437 747 898 1,112 1,385

300.69 0.95 1.14 1.52 1.44 1.82 2.42 2.62 2.36 3.14 0.92 1.26 1.52 1.92 2.42 2.62 3.14

R3/40.15 0.24 0.26 0.25 0.39 0.55 0.53 0.61 0.75 0.75 0.15 0.23 0.25 0.38 0.53 0.62 0.74

253

FWB-J

FWB02JT

Page 55: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Flexi Type Unit

› Quick fixing system for wall/ceiling mounting

› Straight duct connector is mounted to discharge side

› Standard air filter : removable from the bottom

› Electronic controller with water probe, available in

standard, advanced and advanced plus version

FWD

2-PIPE 4-PIPE

Power input High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kWHeating (4-pipe) High kW

Dimensions Height x Width x Depth mmMachine weight kgSound level Sound power High dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/h

Available pressure High PaStandard heat exchanger Water volume lWater connections Std. heat exchanger inchCurrent input High APower supply 1~/230V/50Hz

�� � �� �� ��� �� ��� �� � �� �� ��� �� ���234 349 443 714 1,197 234 349 443 714 1,1973.90 6.20 7.80 8.82 11.90 16.40 18.30 3.90 6.20 7.80 8.82 11.90 16.40 18.303.08 4.65 6.52 7.16 9.36 12.80 14.10 3.08 4.65 6.52 7.16 9.36 12.80 14.104.05 7.71 9.43 10.79 14.45 19.81 21.92 -

- 4.49 6.62 9.21 15.86 21.15280x754x559 280x964x559 280x1,174x559 352x1,174x718 352x1,384x718 280x754x559 280x964x559 280x1,174x559 352x1,174x718 352x1,384x718

33 41 47 49 65 77 80 35 43 50 52 71 83 8666 69 72 74 78 66 69 72 74 78

674 1,064 1,339 1,514 2,056 2,833 3,140 674 1,064 1,339 1,514 2,056 2,833 3,140674 1,064 1,339 1,514 2,056 2,833 3,140 349 581 808 1,392 1,85617 24 16 26 34 45 17 24 16 26 34 4514 20 13 21 28 37 9 15 13 12 16

800 1,250 1,600 2,200 3,000 800 1,250 1,600 2,200 3,00066 58 68 64 97 145 134 63 53 63 59 92 138 128

1.06 1.42 1.79 2.38 2.5 4.02 5.03 0.35 0.47 0.59 1.42 1.723/4 1 3/4 1

0.95 1.58 1.97 3.21 5.37 5.37 0.95 1.58 1.97 3.21 5.37

254

FWD

FWD04AFWD04A FWEC1A FWEC2AFWEC3A

Page 56: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Floor Standing Unit

› Quick fixing system for wall mounting

› Pre-assembled 3-way/4-port ON/OFF valves are available

› Valve packages are insulated, no extra drain pan required

› Valve packages contain balancing valves and sensor pocket

› Fast-on connections for electrical options : no tools needed

› Quick removal of washable filter

› Electrical heater : no relay up to 2kW capacity

› Electronic controller with water probe, available in

standard, advanced and advanced plus version

FWV

2-PIPE 4-PIPE

Power consumption High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kWHeating (4-pipe) High kW

Dimensions Height x Width x Depth mmMachine weight kgSound level Sound power High dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/hStandard heat exchanger Water volume lPiping connections Water inlet/outlet inchCurrent input High APower supply 1~/230V/50Hz

�� �� �� �� � �� �� �� �� �� �� � �� ��37 53 56 98 182 244 37 53 56 98 182 244

1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.881.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.852.14 2.57 3.81 5.63 6.36 7.83 10.03 -

- 1.90 2.10 3.08 5.05 5.30 7.91 9.30564x774x226 564x984x226 564x1,194x226 564x1,404x251 564x774x226 564x984x226 564x1,194x226 564x1,404x25119 20 25 30 31 41 20 21 26 32 33 4445 50 47 52 56 61 66 45 50 47 52 56 61 66

265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816

13 11 12 14 12 19 13 11 12 14 12 199 11 9 10 9 16 7 8 5 10 8 9

319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,3620.5 0.7 1 1.4 2.1 0.5 0.7 1.0 1.4 2.1 2.1

1/2 3/4 1/2 3/40.17 0.24 0.25 0.44 0.43 0.80 1.12 0.17 0.24 0.25 0.44 0.43 0.80 1.12

255

FWV

FWV02CAT ECFWMB6FWEC1A FWEC2AFWEC3A

Page 57: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Wall Mounted Unit

› Wide operating range

› Quiet operation with auto-swing comfort

› Easy to install and maintain

› 3 speed fan motor

› Double-intake centrifugal fans

› Excellent air flow and air distribution

› Flexibility via interchangeable water connection side

› High power air flow

› Insulated with self-extinguishing class 1 heat insulation

› Removable washable air filter

(self-extinguishing class 1)

› Slim and compact aesthetic design

› Wireless remote control up to 9m distance, availability

of a wired or simplified controller

› LED indicator gives an indication on the (normal

or wrong) operation of the unit

FWT

2-PIPE

Power input High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kW

Dimensions Height x Width x Depth mmMachine weight kgSound level Sound power High dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/hStandard heat exchanger Water volume lWater connections Std. heat exchanger inchCurrent input High ARequired power supply 1~/220-240V/50Hz

�� �� �� �� �

24 25 29 66 692.34 2.78 3.22 4.54 5.281.74 2.03 2.35 3.65 4.333.02 3.75 4.10 6.01 6.74

260x799x198 260x899x198 304x1,062x22210 12 16

53 55 61 64402 478 554 781 908402 478 554 781 90848.3 64.7 69.3 50.3 69.342 58.6 60.6 50.6 70.6

467 510 586 1,070 1,1210.49 0.57 0.85

1/2''0.11 0.13 0.29 0.30

256

FWT

MERCA WRC COA-HPAFWT05-06AAT SRC

Page 58: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Flexi Type Unit

› Quick fixing system for wall/ceiling mounting

› Pre-assembled 3-way/4-port ON/OFF valves are available

› Valve packages are insulated, no extra drain pan required

› Valve packages contain balancing valves and sensor pocket

› Fast-on connections for electrical options : no tools needed

› Quick removal of washable filter

› Electrical heater: no relay up to 2kW capacity

› Electronic controller with water probe, available in

standard, advanced and advanced plus version

FWM

2-PIPE 4-PIPE

Power input High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kWHeating (4-pipe) High kW

Dimensions Height x Width x Depth mmMachine weight kgSound level Sound power High dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/hStandard heat exchanger Water volume lWater connections Std. heat exchanger inchCurrent input High ARequired power supply 1~/230V/50Hz

�� �� �� �� � �� �� �� �� �� �� � �� ��37 53 56 98 182 244 37 53 56 98 182 244

1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.881.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.852.14 2.57 3.81 5.63 6.36 7.83 10.03 -

- 1.90 2.10 3.08 5.05 5.30 7.91 9.30535x584x224 535x794x224 535x1,004x224 535x1,214x249 535x584x224 535x794x224 535x1,004x224 535x1,214x24914 15 19 23 32 15 16 20 25 3445 50 47 52 56 61 66 45 50 47 52 56 61 66

265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816

13 11 12 14 12 19 13 11 12 14 12 199 11 9 10 9 16 7 8 5 10 8 9

319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,3620.5 0.7 1 1.4 2.1 0.5 0.7 1 1.4 2.1

1/2 3/4 1/2 3/40.17 0.24 0.25 0.44 0.43 0.80 1.12 0.17 0.24 0.25 0.44 0.43 0.80 1.12

257

FWM

FWM01CFWM01C FWEC1A FWEC2AFWEC3A

Page 59: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Flexi Type Unit

› Quick fixing system for wall/ceiling mounting

› Pre-assembled 3-way/4-port ON/OFF valves are available

› Valve packages are insulated, no extra drain pan required

› Valve packages contain balancing valves and sensor pocket

› Fast-on connections for electrical options : no tools needed

› Quick removal of washable filter

› Electrical heater : no relay up to 2kW capacity

› Electronic controller with water probe, available in

standard, advanced and advanced plus version

FWL

2-PIPE 4-PIPE

Power input High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kWHeating (4-pipe) High kW

Dimensions Height x Width x Depth mmMachine weight kgSound level Sound power dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/hStandard heat exchanger Water volume lWater connections Std. heat exchanger inchCurrent input High ARequired power supply 1~/230V/50Hz

�� �� �� �� � �� �� �� �� �� �� � �� ��37 53 56 98 182 244 37 53 56 98 182 244

1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.881.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.852.14 2.57 3.81 5.63 6.36 7.83 10.03 -

- 1.90 2.10 3.08 5.05 5.30 7.91 9.30564x774x226 564x984x226 564x1,194x226 564x1,404x251 564x774x226 564x984x226 564x1,194x226 564x1,404x25120 21 27 32 33 44 21 22 28 34 35 4645 50 47 52 56 61 66 45 50 47 52 56 61 66

265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816

13 11 12 14 12 19 13 11 12 14 12 199 11 9 10 9 16 7 8 5 10 8 9

319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,3620.5 0.7 1 1.4 2.1 0.5 0.7 1 1.4 2.1

1/2 3/4 1/2 3/40.17 0.24 0.25 0.44 0.43 0.80 1.12 0.17 0.24 0.25 0.44 0.43 0.80 1.12

258

FWL

FWL03CFWL03C ECFWMB6FWEC1A FWEC2AFWEC3A

Page 60: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a
Page 61: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

4-Way Blow Ceiling Mounted Cassette

› Wide operating range

› Quiet operation with auto-swing comfort

› Easy to install and maintain

› Flexibility (2-pipe or 4-pipe)

› 3 speed fan motor

› Double-intake centrifugal fans

› 4 way air discharge and air swing

› Air suction from underneath

› High power air flow

› Slim front panel and aesthetic design

› Removable washable air filter

(self-extinguishing class 1)

› Built-in high pressure drain pump (up to 700mm

condensate water can be pumped)

› Wireless controller as standard with decoration panel kit

FWC

2-PIPE 4-PIPE

Power input High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kWHeating (4-pipe) High kW

Dimensions Height x Width x Depth mmMachine weight kgSound level Sound power High dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/hStandard heat exchanger Water volume lWater connections Std. heat exchanger inchCurrent power input High ARequired power supply 1~/220-240V/50Hz

� �� �� �� �� �� �� �� �� �

127 151 164 192 253 122 138 153 184 2326.63 7.50 8.80 9.95 10.80 3.81 3.96 4.63 5.01 5.164.90 5.40 6.40 7.10 7.70 3.40 3.52 4.07 4.40 4.548.40 9.50 11.00 12.00 12.90 -

- 10.55 10.99 12.51 13.48 13.77335x820x821

31 32 35 38 40 31 32 35 38 4052 55 60 61 64 52 55 60 61 64

1,140 1,290 1,514 1,711 1,858 655 681 796 862 8881,140 1,290 1,514 1,711 1,858 -24.8 30.8 41.6 52.2 69.3 3.56 3.78 4.94 5.7 5.9621.4 26.8 35.3 45.2 64.1 -

1,310 1,380 1,560 1,740 1,840 1,310 1,380 1,560 1,740 1,8402.693/4''

0.52 0.64 0.68 0.79 1.06 0.53 0.61 0.67 0.8 1.02

260

FWC

FWC08AAT SRC MERCA WRC COA-HPA

Page 62: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

4-Way Blow Ceiling Mounted Cassette

› Quiet operation with auto-swing comfort

› Easy to install and maintain

› 3 speed fan motor

› Double-intake centrifugal fans

› 4 way air discharge and air swing

› Air suction from underneath

› High power air flow

› Slim front panel and aesthetic design

› Tile size decoration panel

› Removable washable air filter

(self-extinguishing class 1)

› Built-in high pressure drain pump (up to 700mm

condensate water can be pumped)

› Wireless controller as standard with decoration panel kit

FWF

2-PIPE

Power input High WCapacity Cooling Total High kW

Cooling Sensible High kWHeating (2-pipe) High kW

Dimensions Height x Width x Depth mmMachine weight kgSound level Sound power dBAWater flow Cooling l/h

Heating l/hWater pressure drop Cooling kPa

Heating kPaFan Air flow rate High m³/hStandard heat exchanger Water volume lWater connections Std. heat exchanger inchCurrent input High ARequired power supply 1~/220-240V/50Hz

�� �� ��

51 75 782.34 4.10 4.251.97 3.06 3.243.22 5.12 5.42

250x570x57022 2354 53 56

402 705 731402 705 73167.3 68.6 68.861.9 70.5 71.2

662 7310.56 1.15 1.15

3/40.22 0.30 0.34

261

FWF

FWF-AT SRC MERCA WRC COA-HPA

Page 63: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

262

174

Daikin Air Handling Units

The Daikin Air Handling Units are based on a completely modular design,

capable of adapting to the needs of a variety of installation types. A wide

standard range covers air fl ow rates from 1,100m³/h up to 124,000m³/h while

paying special attention to energy effi ciency.

System highlights

› Custom modular design with variable dimensioning

› Rigid 40mm and 60mm extruded aluminium profile structure

› Double wall 25mm and 50mm foam or rockwool filled panels

› Component flexibility for total air treatment: Heat Recovery &

Humidification

› Air flow rates from 1,100 up to 124,000m3/h

Aluminium profile with thermal break

Robust thermal-break construction

The air handling unit is constructed of aluminium, using anodised aluminium

profi les and double-walled panels.

The profi les have a section of 40x40mm or 60x60mm.

The 60x60mm profi les are also available in a thermal-break version.

The following insulation material is used between the sheets:

› Polyurethane foam (40-50 kg/m3)

› Mineral wool, glued to the panel (90 kg/m3)

The panels are available as fl at panels or as step panels,

which permit to obtain a fl at surface inside the unit.

The inner and outer sheet of the panel can be made with the following

materials:

› Plastisol

› Galvanised steel

› Aluminium

› Stainless steel

› Pre-painted

STANDARD 01-09

Air flow rate (m3/h) x 1,000

Mo

de

l si

ze

X������!?�(L�

X������!?�(L�

X������!��(L�

X������!��(L�

STANDARD 10-18

Mo

de

l si

ze

Air flow rate (m3/h) x 1,000

STANDARD 19-27

Mo

de

l si

ze

Air flow rate (m3/h) x 1,000

X������!?�(L�

X������!?�(L�

X������!��(L�

X������!��(L�

X������!?�(L�

X������!?�(L�

X������!��(L�

X������!��(L�

Page 64: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

263

Mineral wool

Flat panel

Step panel

Model sizeAir fl ow rate at

2.5m/sLength Height

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

Filters

› Pre-filters:

- Pleated filter (G3,G4)

- Flat filter (G1,G2)

› Medium efficiency filter:

- Bag filters (rigid or soft) (F5 ÷ F9)

› High efficiency filters (up to H13)

› Active carbon filters

- Adsorption filters

- Deodorizing filters

Centrifugal fans

› Forward bladed fans

› Backward bladed fans

› Centrifugal fan

› Belt or direct drive

Other

› Damper

› Mixed section

› Empty section

› Gas burner section

› Drip tray

Humidifiers

› Surface evaporation humidifier

› Water spray humidifier

› Steam humidifier (on network with generator)

› Atomized water spray humidifier

Heat exchangers

› Material:

Cu/Al

Cu/Alprepaint

Cu/Cu

galvanised Fe

RVS304

RVS316

› Water coil

› Steam coil

› Direct expansion coil

› Superheated water coil

› Electric coils

Heat recovery

› Heat wheel ( efficiency 70 ÷75%)

› Plate heat exchanger (efficiency 50 ÷60%)

› Twincoil heat exchanger (efficiency 50 ÷60%)

COMPONENTS OF AIR HANDLING UNITS

« O ffer ing a complete range: f rom standard model s izes to customised solut ions. »

1,105 850 550

1,550 900 600

1,980 950 650

2,570 1,000 780

3,170 1,150 780

3,550 1,150 800

4,000 1,250 800

4,800 1,300 850

5,560 1,350 900

6,600 1,550 900

7,950 1,550 1,100

9,320 1,650 1,100

10,050 1,650 1,150

13,200 1,850 1,400

19,200 2,100 1,500

25,300 2,650 1,500

31,500 2,750 1,750

37,000 3,220 1,800

43,400 3,090 2,100

51,300 3,340 2,250

58,000 3,820 2,250

67,500 4,040 2,400

78,000 4,490 2,450

84,700 4,490 2,700

98 000 4,890 2,850

111,000 5,490 2,850

124,000 5,990 3,000

Page 65: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a
Page 66: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Daikin offers a wide range of condensing units for medium and low temperature refrigeration applications. Daikin refrigeration units combine efficiency and reliability with easy installation and maintenance.

Q��QR�Q�SRY Conveni-pack 266ZEAS condensing units 270Commercial condensing units 272High capacity inverter controlled condensing units 273

NEW

NEW

Page 67: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

In other words, a single Conveni-pack system combines:

› interior units for heating and cooling

› refrigeration showcases

› deep-freeze cabinets.

Why do you need Conveni-Pack?

› a low energy system

› limits your CO2 emissions

› optimises your available space

› satisfies your customer comfort

The food retailing revolution that saves space and energy consumption

Conveni-pack is a highly innovative and revolutionary system that has been

developed by Daikin to address the requirements of a challenging retail envi-

ronment.

Conveni-pack integrates heating, cooling and low/high temperature

refrigeration in one system.

Heating, cooling and refrigeration in one system?

You are not dreaming. Conveni-pack consists of heating, cooling AND low/

high refrigeration units, all combined in a single, compact and integrated

system.

Until now, conventional systems for low/high refrigeration, heating and cooling

systems have been separated from one another, requiring space and numerous

piping connections.

Conveni-pack totally revolutionises this approach.

It consists of an inverter driven outdoor unit and indoor air conditioning units

that can be connected to low/high temperature refrigeration cabinets and/or

unit coolers.

A revolution based on a great tradition

It’s no surprise that Daikin has innovated such a revolutionary concept, because

Conveni-pack is based on a pioneering system that Daikin introduced back in

1985.

Daikin’s Variable Refrigerant Volume (VRV®) technology transformed the

industry’s approach to cooling and heating large buildings. For the first time,

multiple indoor heating and cooling units could be connected to a single

outdoor unit. Furthermore, the volume of the refrigerant could be varied to

respond to changing needs.

The benefits of VRV® are impressive: more accurate temperature

control, increased reliability, unheard of efficiencies, and most

importantly, energy and cost savings.

Since then, VRV® has become an industry standard and is currently

recognised as one of the most efficient and reliable ways to heat and

cool all types of buildings.

Following in the footsteps of VRV®, comes Conveni-pack, a state-of-the-

art solution for today’s urban retail environment.

266

CONVENI-PACK

Page 68: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

What store size is Conveni-Pack suitable for?

Conveni-pack is specifically designed and developed for small to medium-sized

stores or petrol stations. Furthermore, the concept is scalable, so can be easily

expanded as your facility grows.

Small stores

For small convenience stores and petrol stations, a single Conveni-pack system

is all that is required. Compared to conventional systems, a great advantage of

Conveni-pack for a small store is the simplified piping required to connect the

Conveni-pack outdoor unit to the indoor services. Instead of eight pipes you

need just three, as fewer units have to be inter-connected.

Medium-sized stores

For larger applications, multiple outdoor units can be connected to a variety of

refrigeration systems and air conditioning units. What’s more, the modularity

of the Conveni-pack system maximises installation flexibility. Outdoor

units can be grouped into blocks or rows, or distributed

around the building, to meet specific requirements

of the installation. Additionally, the outdoor units

can be located above or below the refrigeration

cabinets, inside the building and with long runs if

required.

To select multiple systems, use the combined

refrigeration and air conditioning loads, as shown in

the illustration. Conventional air conditioning or integral

refrigeration systems are added where required. This process

maximizes the benefits of using Conveni-pack.

267

Page 69: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Outdoor unit

The inverter driven outdoor unit has a smaller footprint than standard systems

and requires less piping to connect it to the indoor units.

Very quiet operation

Global average sound level pressure at 10m

› Refrigeration high load: 46 dBA

› Refrigeration high load with partial heat recovery: 42 dBA

› Night time operation, low refrigeration load : 31 dBA

The outdoor unit can even be quieter with the sound insulation kit option.

What’s included in the Conveni-Pack system?

The great flexibility of Conveni-pack means you can select exactly the number

of systems you require, as well as various indoor unit options to maximise your

investment.

4-way blow ceiling

mounted cassette

4-way blow ceiling

suspended cassette

Ceiling suspended unit

2-way blow ceiling

mounted cassette

High ESP ducted unit Low ESP ducted unit

Round flow cassette

Air conditioning indoor units

› Round flow cassettes are suitable for the majority of applications.

›› 360° air discharge ensures uniform air flow and temperature distribution

›› Fresh air intake: up to 20 % (optional kit required)

›› Comfortable horizontal air discharge ensures draught

free operation and prevents ceiling soiling

› Ceiling suspended units can be used where no ceiling cavity is available.

› Concealed ceiling units are available in high or low External Static

Pressure (ESP) versions for installation where control over the distribution

is required, for example between aisles of refrigeration cabinets, or

as an energy efficient alternative to direct electric air curtains.

Energy saving

Using Conveni-pack can reduce annual energy consumption by as much as 50%

when compared to conventional systems, by using optimised controls, inverter

technology and heat recovery. The controls and inverter provide a baseline

efficiency gain of 27% and heat recovery can provide up to 23% further energy

saving depending on the outdoor temperature.

1 2 3 4 5 6 7 8 9 10 11 12 13

12000

10000

8000

6000

4000

2000

Month

kW

h

Conventional System

Conveni-pack

60% saving in

Winter

20% saving in Summer 50%

average over the

year

268

Page 70: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Freezer booster pack

Conveni-pack can be provided with a freezer booster pack for use with low

temperature refrigeration. This option brings additional energy savings and

simplifies installation by limiting the length of heavily insulated pipe required.

The freezer booster pack is installed indoors.

The freezer booster pack contains a satellite compressor which provides the

first compression stage from -35°C into the suction line of the high temperature

refrigeration. The second stage compression is performed in the outdoor unit.

This allows significantly lower compression rates, energy consumption and end

temperatures.

Air conditioning network service systems online monitoring service

Air conditioning network service systems is a 24-hour, 7/7 online monitoring

service for Conveni-pack that increases the quality of periodic inspection and

maintenance. Air conditioning network service systems immediately detects if a

malfunction occurs before the tenants are even aware of the situation.

Reliable periodic inspection ensures Conveni-pack always performs at top levels

and continues to deliver its energy-saving benefits. Air conditioning network

service systems supports this by providing engineers with valuable diagnostic

information.

269

Page 71: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

ZEAS CONDENSING UNITS

A comprehensive product range with 1, 2 or 3 compressors

› Medium temperature applications : 12.2 to 37.0 kW at -10°C /+32°C

› Low temperature applications 5.4 to 15.1 kW at -35/+32°C

Inverter controlled scroll compressors open the door to VRV® technology for commercial refrigeration.

Medium temperature

Power supply 3~/380-415V/50Hz

Capacity (2) kW

Range of suction pressure equivalent saturation temperature "�Range of outdoor temperature "�Dimensions Height x Width x Depth mm

Heat exchanger Cross fin coil

Compressor

N° of compressors

Type Hermetically sealed scroll type

Swept volume m3/h

Number of revolutions r.p.m

Motor output × number of compressors kW

Starting method Direct-on-line (Inverter system)

Fan

Type Propeller fan

Motor output kW

Air flow rate m3/min

Drive Direct drive

Connecting pipesLiquid pipe Ø 9.5 C1220T (Brazing connection) Ø 12.7 C1220T (Brazing connection)

Gas pipe Ø 19.1 C1220T (Brazing connection) Ø 25.4 C1220T (Brazing connection) Ø 31.8 C1220T (Brazing connection)

Receiver volume l

Mass

RefrigerantType

Charge volume kg

Refrigerant oilRefrigerant oil name DAPHNE FVC68D

Charge volume l

Sound pressure (3)At 1m dBA

At 10m dBA

Maximum starting current (380V/400V/415V) A - -

Nominal running current (380V/400V/415V) A

(1) shows the salt damage-proof specification machine.(2) Rated conditions of the refrigeration equipment : Saturated temperature equivalent to suction pressure : -10°C, Outdoor air: 32°C, Suction SH: 10°C(3) Measurement place: Front: 1m, Height: 1.5m according to EN13900(4) (E) Special coating for harsh environmental conditions (option)

Designed for outdoor use, the condensing units are a perfect medium capacity

commercial refrigeration solution for cold stores or freezer rooms, food retails,

petrol stations shops, etc in low and medium temperature applications

LRMEQ5AY1(E )(4) LRMEQ6AY1(E )(4) LRMEQ8AY1(E )(4) LRMEQ10AY1(E)(4) LRMEQ12AY1(E)(4) LRMEQ15AY1(E)(4) LRMEQ20AY1(E)(4)

12.2 14.4 18.6 21.8 24.4 32.2 37.0

-20 ~ +10

-15 ~ +43

1,680 × 635 × 765 1,680 × 930 × 765 1,680 × 1,240 × 765

1 1 2 2 2 3 3

10.04 13.85 19.68 23.36 25.27 30.00 35.80

4,740 6,540 4,320/ 2,900 6,060/ 2,900 6,960/2,900 5,640/2,900/2,900 6,960/2,900/2,900

2.3 3.2 2.1+3.6 3.0+3.6 3.4+3.6 2.8+3.6+3.6 3.4+3.6+3.6

0.35×1 0.75×1 0.75×2

95 102 171 179 191 230 240

5.4 8.1 12.1

175 255 355

R-410A

5.2 7.9 11.5

1.7+2.5 1.7+2.1+3.0 1.7+2.1+2.1+4.0

55 56 57 59 61 62 63

34 36 37 39 41 42 43

78 / 74 / 72 79 / 75 / 73 89 / 84 / 81

7.5 / 7.0 / 6.8 9.4 / 8.9 / 8.6 12.7 / 12.0 / 11.8 15.2 / 14.4 / 14.0 18.1 / 17.2 / 16.7 37.7 / 21.6 / 20.8 27.3 / 25.8 / 25.0

270

LRMEQ5-6AY1 LRMEQ8-10-12AY1 LRMEQ15-20AY1

Page 72: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

› System solution for variable refrigeration load systems

› Single or multiple evaporators and cabinets can be connected

› Booster compressor for low temperature application can be connected to a medium temperature condenser unit

› High energy efficiency with DC inverter

› Very quiet

› Very compact

› Refrigerant: R-410A

› Easy to install

Low temperature LRLEQ5AY1(E)(4) LRLEQ6AY1(E)(4) LRLEQ8AY1(E)(4) LRLEQ10AY1(E)(4) LRLEQ12AY1(E)(4) LRLEQ15AY1(E)(4) LRLEQ20AY1(E)(4)

Power supply 3~/380-415V/50Hz

Capacity (2) kW

Range of suction pressure equivalent saturation temperature "�Range of outdoor temperature "�Dimensions Height x Width x Depth mm

Heat exchanger Cross fin coil

Compressor

N° of compressors

Type Hermetically sealed scroll type

Swept volume m3/h

Number of revolutions r.p.m

Motor output × number of compressors kW

Stating method Direct-on-line(Inverter system)

Fan

Type Propeller fan

Motor output kW

Air flow rate m3/min

Drive Direct drive

Connecting pipesLiquid pipe Ø 9.5 C1220T (Brazing connection) Ø 12.7 C1220T (Brazing connection)

Gas pipe Ø 19.1 C1220T (Brazing connection) Ø 25.4 C1220T (Brazing connection) Ø 31.8 C1220T (Brazing connection)

Receiver volume l

Mass

RefrigerantType

Charge volume kg

Refrigerant oilRefrigerant oil name DAPHNE FVC68D

Charge volume l

Sound pressure (3)At 1m dBA

At 10m dBA

Maximum starting current (380V/400V/415V) A

Nominal running current (380V/400V/415V) A

(1) shows the salt damage-proof specification machine.(2) Rated conditions of the refrigeration equipment : Saturated temperature equivalent to suction pressure : -35°C, Outdoor air: 32°C, Suction SH: 10°C (3) Measurement place: Front: 1m, Height: 1.5m according to EN13900 (4) (E) Special coating for harsh environmental conditions (option)

LRLEQ5AY1(E)(4) LRLEQ6AY1(E)(4) LRLEQ8AY1(E)(4) LRLEQ10AY1(E)(4) LRLEQ12AY1(E)(4) LRLEQ15AY1(E)(4) LRLEQ20AY1(E)(4)

5.4 6.3 8.0 9.4 10.3 13.6 15.1

-45 ~ -20

-15 ~ +43

1,680 × 635 × 765 1,680 × 930 × 765 1,680 × 1,240 × 765

1 1 2 2 2 3 3

10.04 13.85 19.68 23.36 25.27 30.00 35.80

4,740 6,540 4,320/ 2,900 6,060/ 2,900 6,960/2,900 5,640/2,900/2,900 6,960/2,900/2,900

2.3 3.2 2.1+3.6 3.0+3.6 3.4+3.6 2.8+3.6+3.6 3.4+3.6+3.6

0.35×1 0.75×1 0.75×2

95 102 171 179 191 230 240

5.4 8.1 12.1

175 255 355

R410A

5.2 7.9 11.5

1.7+2.5 1.7+2.1+3.0 1.7+2.1+2.1+4.0

55 56 57 59 61 62 63

34 36 37 39 41 42 43

- - 78 / 74 / 72 79 / 75 / 73 89 / 84 / 81

6.7 / 6.4 / 6.2 8.4 / 8.0 / 7.7 11.3 / 10.7 / 10.4 14.0 / 13.3 / 12.9 14.7 / 14.0 / 13.6 19.7 / 18.6 / 17.9 21.5 / 20.4 / 19.6

271

Page 73: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

COMMERCIAL CONDENSING UNITS

Model

Se

rie

s

HP Capacity** Electrical Data Condenser Dimensions Weight Sound

pressure

R-404A

-10/+32°C

R-134a

-10/+32°CPower Input

Nominal

Current

(A)

Airfl ow

(m3/h)Width (mm)

Depth

(mm)

Height

(mm)(kg)

dBA at

10m*

Med

ium

Tem

per

atur

esLo

w T

emp

erat

ures

* Sound pressure level measured following ISO 3744.

** Rated conditions of the refrigeration equipment: SH = 10 K; SC = 0 K

Designed for outdoor use, the condensing units are a perfect commercial refrigeration solution for cold stores or freezer rooms, small food retails,

restaurants, petrol station shops, etc in low and medium temperature applications.

Main benefits

› Low operation sound level

› Easy to install - fully equipped - packaged

› Energy efficiency and performance

› Robust and reliable design

Installer benefits

› Small, compact and robust for easy handling and installation in limited

space

› Fully factory tested and pre-wired electrical box for quick and easy

installation and commissioning

› Easy service thanks to very accessible components behind removable

robust panels

› Parts and support available in the complete Daikin network

End-user benefits

› Very quiet operation

› Strong anti-corrosion housing for long life, even in harsh

environmental conditions

› Dependable units, with proven component reliability and fully

qualified for the most demanding applications

› Reduced energy consumption, thanks to efficient compressors and

condenser fan speed control (except series 1)

› Fully packaged unit at a competitive price

JEHCCU0050M1 1 0.5 871 - 1~/230V/50Hz 3.95 1,910 865 345 485 46 29

JEHCCU0088M1 1 0.88 1,478 - 1~/230V/50Hz 4.70 1,910 865 345 485 46 29

JEHCCU0150M1 2 1.5 2,062 1,229 1~/230V/50Hz 6.6 3,040 1,109 478 649 82 37

JEHCCU0150M3 2 1.5 2,062 1,229 3~/400V/50Hz 2.7 3,040 1,109 478 649 82 37

JEHCCU0225M1 2 2.25 3,451 1,958 1~/230V/50Hz 10.9 2,620 1,109 478 649 89 36

JEHCCU0225M3 2 2.25 3,451 1,958 3~/400V/50Hz 4.0 2,620 1,109 478 649 89 36

JEHCCU0300M1 2 3 4,506 2,948 1~/230V/50Hz 15.0 2,620 1,109 478 649 89 37

JEHCCU0300M3 2 3 4,506 2,948 3~/400V/50Hz 4.9 2,620 1,109 478 649 89 37

JEHCCU0400M3 3 4 6,527 3,925 3~/400V/50Hz 6.4 6,130 1,334 530 883 120 36

JEHCCU0500M3 3 5 8,021 4,823 3~/400V/50Hz 8.2 6,130 1,334 530 883 120 40

JEHCCU0600M3 3 6 8,897 5,860 3~/400V/50Hz 8.5 5,160 1,334 530 883 126 40

JEHCCU0675M3 3 6.75 9,756 6,153 3~/400V/50Hz 10.0 5,160 1,334 530 883 126 42

JEHCCU0825M3 4 8.25 11,010 7,083 3~/400V/50Hz 12.0 10,830 1,244 510 1,431 204 42

JEHCCU1000M3 4 10 13,528 8,667 3~/400V/50Hz 13.5 10,830 1,244 510 1,431 205 42

-30/+32°C

JEHCCU0075L1 1 0.75 562 1~/230V/50Hz 4.28 1,910 865 345 485 46 30

JEHCCU0175L1 2 1.75 1,277 1~/230V/50Hz 4.4 3,040 1,109 478 649 86 35

JEHCCU0175L3 2 1.75 1,277 3~/400V/50Hz 2.1 3,040 1,109 478 649 86 35

JEHCCU0225L1 2 2.25 2,044 1~/230V/50Hz 9.2 2,620 1,109 478 649 92 38

JEHCCU0225L3 2 2.25 2,044 3~/400V/50Hz 3.4 2,620 1,109 478 649 92 38

JEHCCU0350L3 3 3.5 2,567 3~/400V/50Hz 3.3 6,130 1,334 530 883 125 38

JEHCCU0400L3 3 4 3,757 3~/400V/50Hz 6.1 6,130 1,334 530 883 125 38

JEHCCU0725L3 4 7.25 5,549 3~/400V/50Hz 7.5 10,830 1,244 510 1,431 203 41

JEHCCU0825L3 4 8.25 7,514 3~/400V/50Hz 9.7 10,830 1,244 510 1,431 203 40

272

Page 74: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

HIGH CAPACITY INVERTER CONTROLLED CONDENSING UNITS

�������� !������" #������$ !����

�� �� �� %&��'�

A comprehensive product range with 1 or 2 compressors and 4 to 10

condenser fans

› Chilled application: 113 - 417 kW

(at T0 = -10°C / Tamb = +32°C / R-404A)

› Frozen application: 37 - 159 kW

(at T0 = -35°C / Tamb = +32°C / R-404A)

Designed for outdoor use, the large condensing units are a perfect medium

to high capacity refrigeration solution for cold stores, distribution platforms,

supermarkets, food processing, etc in low and medium temperature

applications

These industrial condensing units are real workhorses

designed for maximum performance in minimum space.

› High energy efficiency: inverter controlled compressor,

economizer, high performance condenser

› Possibility of having a stand-by compressor

› Very quiet

› Easy installation, ready to connect evaporators

› Integrated starter and control panel with electronic controller

› Approved according to EN 378-2008 (safety,

pressure, EMC and voltage directive)

› Refrigerants: R-404A, R-134a, R-407C, R-507A

�#�$� �#�%� �#%$� �#$��$#'$� �#�%� �#%$� $#$'(

273

Page 75: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a
Page 76: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

��

OPTIONS & ACCESSORIES

CONTROL SYSTEMS 276

Individual control systems 276

Wired remote control 276Infrared remote control 276Simplifi ed built-in remote control for hotel applications 276Simplifi ed remote control 276

Centralised control systems 277

Centralised remote control 277Unifi ed on/off control 277Schedule timer 277

Network solutions 278

278

279

280

281

281

OPTIONS, CONTROL SYSTEMS & ACCESSORIES 282

Split 282Sky Air® 284VRV® Outdoor 288VRV® Indoor 292Ventilation 294Applied Systems 296

NEW

Page 77: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

BRC1E51AWired remote control

User-friendly remote control with contemporary design. › Easy to use: all main functions directly accessible › Easy setup: improved graphical user interface for advanced menu settings › Real time clock with auto update to daylight saving time › Schedule timer with holiday setting, improved

weekly timer and home leave operation › Supports multiple languages (English, German, Dutch,

Spanish, Italian, Portuguese, French, Greek, Russian, Turkish) › Built-in backup power: when a power failure occurs

all settings remain stored up to 48 hours

Display › Operating mode › Heat Recovery Ventilation (HRV) in operation › Cool / heat changeover control › Centralised control indication › Group control indication › Set temperature › Air flow direction › Programmed time › Inspection test / operation › Fan speed › Clean air filter › Defrost / hot start › Malfunction

BRC1D52Wired remote control

› Schedule timer:• Five day actions can be set as follows:

- set point: unit is switched ON and normal operation is maintained - OFF: unit is switched OFF - limits: unit is switched ON and min./max. control

(cf. limit operation for more details) › Home leave (frost protection): during absence, the

indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF

› User friendly HRV function, thanks to the introduction of a button for ventilation mode and fan speed

› Constantly monitoring of the system for malfunctions in a total of 80 components

› Immediate display of fault location and condition › Reduction of maintenance time and costs

BRC4*/BRC7*Infrared remote control

Operation buttons: ON/OFF, timer mode start/stop, timer mode on/off, programme time, temperature setting, air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only), operating mode, fan speed control, filter sign reset, inspection / test indication

Display: Operating mode, battery change, set temperature, air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only), programmed time, inspection/test operation, fan speed

BRC3A61Simplified built-in remote control for hotel

applications

Compact, user friendly unit, ideal for use in hotel bedrooms

Operation buttons: ON/OFF, fan speed control, temperature setting

Display: Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost/hot start, malfunction

BRC2C51Simplified remote control

Simple, compact and easy to operate unit, suitable for use in hotel bedrooms

Operation buttons: ON/OFF, operating mode selection, fan speed control, temperature setting

Display: Cool/heat changeover control, Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost/hot start, malfunction adjustment, operating mode selection, fan speed control, filter sign reset, inspection test/operation

Individual Control Systems

276

BRC3A61BRC2C51BRC4*/BRC7*BRC1D52BRC1E51A

Page 78: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Centralised control of the VRV® system can be achieved via 3 user friendly compact controls: centralised remote control, unified on/off control and schedule timer. These controls may be used independently or in combination where 1 group = several (up to 16) indoor units in combination and 1 zone = several groups in combination.A centralised remote control is ideal for use in tenanted commercial buildings subject to random occupation, enabling indoor units to be classified in groups per tenant (zoning). The schedule timer programmes the schedule and operation conditions for each tenant and the control can easily be reset according to varying requirements.

DCS302C51Centralised remote control

Providing individual control of 64 groups (zones) of indoor units.

• a maximum of 64 groups (128 indoor units, max. 10 outdoor units) can be controlled

• a maximum of 128 groups (128 indoor units, max. 10 outdoor units) can be controlled via 2 centralised remote controls in separate locations

• zone control• group control• malfunction code display• maximum wiring length of 1,000m (total:

2,000m)• air flow direction and air flow rate of HRV can

be controlled• expanded timer function

DCS301B51Unified ON/OFF control

Providing simultaneous and individual control of 16 groups of indoor units.

• a maximum of 16 groups (128 indoor units) can be controlled

• 2 remote controls in separate locations can be used

• operating status indication (normal operation, alarm)

• centralised control indication• maximum wiring length of 1,000m (total:

2,000m)

DST301B51Schedule timer

Enabling 64 groups to be programmed.

• a maximum of 128 indoor units can be controlled

• 8 types of weekly schedule • a maximum of 48 hours back up power supply• a maximum wiring length of 1,000m (total:

2,000m)

Centralised Control Systems

277

DST301B51DCS301B51DCS302C51

Page 79: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Network Solutions

FUNCTIONS

1. Monitoring FunctionsYou can monitor your air conditioning units by simply sending a text message with your mobile phone with the word “Report”: › Start/stop › Operation mode (fan/cool/heat) › Temperature setting › Error code

2 . Control FunctionsYou can control your air conditioning units by simply sending a text message via your mobile phone: › Start/stop › Operation mode (fan/cool/heat) › Temperature setting

3. Error NotificationWhen an error occurs, a text message will be sent automatically to your mobile phone (error notification).

4. Stand alone operation › Rotation function › Backup operation function.

Basic solution for control of

Sky Air® and VRV®

› monitoring function › control function › error notification

Mobile phoneUp to 4 units / 1 adapter

GSM modem

RS232C

DS-NET adapter

278

BRC1D52

Page 80: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Network Solutions

LANGUAGES

› English › French › German › Italian › Spanish › Dutch › Portuguese

SYSTEM LAYOUT

› Up to 2 x 64 indoor units can be controlled › Onboard Ethernet port (web

browser + e-mail) › Digital i/o contacts (option) › Touch panel (full colour

LCD via icon display)

MANAGEMENT

› Web application & internet compatibility

- Monitoring & control according to user

- Remote monitoring & control of more than

one building

- Remote monitoring & control of more than

one building via internet

› Power Proportional Distribution: PPD (option)

› PPD data is available on the internet › Easy management of

electricity consumption › Enhanced history function

CONTROL

› Individual control (set point, start/stop, fan speed) (max. 2 x 64 groups/indoor units)

› Set back shedule › Enhanced scheduling function

(8 schedules, 17 patterns) › Flexible grouping in zones › Yearly schedule › Fire emergency stop control › Interlocking control › Increased HRV monitoring

and control function › Automatic cooling / heating change-over › Heating optimization › Temperature limit › Password security: 3 levels (general,

administration & service) › Quick selection and full control › Simple navigation

MONITORING

› Visualisation via Graphical User Interface (GUI)

› Icon colour display change function › Indoor units operation mode › Error messages via e-mail &

mobile phone (option) › Indication fi lter replacement › Multi PC

COST PERFORMANCE

› Free cooling function › Labour saving › Easy installation › Compact design: limited installation space › Overall energy saving

OPEN INTERFACE

› Communication to any third party controller (domotics, BMS, etc.) is possible via open interface

› Http option

CONNECTABLE TO

› VRV®

› HRV › Sky Air® (via interface adapter) › Split (via interface adapter)

Detailed & easy monitoring and operation of

VRV® systems

(max. 2 X 64 groups/indoor units).

Malfunction

Remote monitoring/control via internet, e-mail

PPD data is available on the internet

Onboard

Ethernet port

Links to the wattmeter when using the PPD

(option) function

Pi-port

Public line

Air conditioning Network

Service System

CSV output of PPD (option)

result

third party controller (domotics,

BMS, etc.)

Ethernet Fire alarm

DIII-NET

DIO unit

DI unit

Controls drain

pump lighting etc.

Monitoring of

room enter/

exit sign

DIII-NET Allows monitoring/control of up to

64 units (groups) of A/Cs and equipment

DIII-NET PLUS

adapter

Forced OFF contact input

HRV

HRV

Indoor units

Indoor units

RS-232C

Onboard

modem

PCMCIA

fl ash

memory

279

Page 81: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Network Solutions

LANGUAGES

› English

› French

› German

› Italian

› Spanish

› Dutch

› Portuguese

SYSTEM LAYOUT

› Up to 1,024 indoor units can

be controlled (by 4 iPUs)

› Ethernet TCPIP / 10 base / T communication

› Integrated digital contacts on the

Intelligent Processing Unit (iPU)

- 20 general input ports

- 2 digital outputs

› Stand alone operation of the

iPU for minimum 48 hours

› Compatible with UPS shutdown software

MANAGEMENT

› Web access (option)

› Power Proportional Distribution (option)

› Operational history management (start/

stop, malfunction, operation hours)

› Generation of reports (graphics &

tables) (daily, weekly, monthly)

› Peak load shedding

› Advanced tenant management

› Sliding temperature

› Eco mode (option)

› Pre-cooling and -heating function

CONTROL

› Individual control (setpoint, start/stop,

fan speed) (max. 1,024 indoor units)

› Group control (100 groups)

› Schedule control (128 programs)

› Fire emergency stop control (32 programs)

› Interlocking control

› Setpoint limitation

› Automatic cooling/heating change-over

› Power failure/release control

› Temperature limit (automatic start)

› Timer extension

MONITORING

› Visualisation via a Graphical User

Interface (GUI) featuring free layout

› Operation mode of indoor units

› Fault indication

› Indication filter replacement

› Setpoint indication

› Operation time monitoring

› Multi PC

› On-line help

COST PERFORMANCE

› Labour saving

› Easy installation

› Compact design: limited installation space

› Overall energy saving

CONNECTABLE TO

› VRV®

› HRV

› Sky Air® (via interface adapter)

› Split (via interface adapter)

Full control and management of VRV® systems

(Maximum 200 groups)

DIII-NET

DIII-NET

DIII-NET

Web Access

Sub PC

ETH

ERN

ET

Intranet/InternetWeb Access

Malfunction report by E-Mail

Dio unit

· Elevator· Pump· Lighting,...

Power supply facility

Ai unit

Daikin Central Air Conditioning System

VRV® SystemLocal

monitoring & control

Air Conditioning Network Service System (Optional Maintenance Service)

HRV

Electricity Measurement

Fire alarm

(Via Internet)

DAM602B51/52

DIII-N

ET

DMS502A51(monitoring only)

Windows Vista® Compatible

280

~

~

Page 82: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Network Solutions

Open network integration of VRV® monitoring and

control functions into LonWorks networks › Interface for Lon connection

to LonWorks® networks › Communication via Lon®

protocol (twisted pair wire) › 64 units connectable per DMS-IF › Unlimited sitesize › Quick and easy installation

LON® BMS

Fire alarm System

Security

BUILDING CONTROL NETWORK

adapter

LonTalk

LonTalk

LonPoint LonPoint

ETH

ERN

ET (T

CP/

IP)

adapter

DMS504B51

Local Control

DIII- NET

VRV®

Outdoor unit

HRV

Remote Control

DAIKIN A/C INFRASTRUCTURE

Network Solutions

› PPDdata is available on BMS system › Interface for BMS system › Communication via BACnet protocol

(connection via Ethernet) › 256 units connectable per

BACnet gateway › Unlimited sitesize › Easy and fast installation

BAC

NET

/ E

THER

NET

Fire alarm Security

Local Control

DIII- NET

VRV®

Outdoor unit

Remote Control

DAIKIN A/C INFRASTRUCTURE

Power supply facility

Pump Lighting Elevator

HRV

DAM602B51/52

Integrated control system for seamless connection

between VRV® and BMS systems

BUILDING CONTROL NETWORK

281

BACnet Interface

LonWorks Interface

Page 83: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

INDOOR UNITS - CONTROL SYSTEMS FTXR28E FTXR42E FTXR50E CTXU25G CTXU35G CTXU42G CTXU50G FTXG25J

Wired remote control

Wiring adapter for time clock Normal open contact KRP413A1S (1) KRP413A1S (1)

Remote control Normal open pulse contact KRP413A1S (1) KRP413A1S (1)

Centralised control board Up to 5 rooms KRC72A (2) KRC72A (2)

Central remote control DCS302CA51 (4) DCS302CA51

Unified on/off control DCS301BA51 (4) DCS301BA51

Schedule timer DST301BA51 (4) DST301BA51

Interface adapter KRP928BA2S (3) KRP928BA2S (3)

Notes

(1) Wiring adapter supplied by daikin. Time clock and other devices: to be purchased locally.

(2) Wiring adapter is also required for each indoor unit.

(3) For DIII-net adapter

(4) Only for Europe

INDOOR UNITS FTXR28E FTXR42E FTXR50E CTXU25G CTXU35G CTXU42G CTXU50G FTXG25J*

Air purification and deodorising filter set without frame KAF974B42S

Air supply filter with frame KAF963A43

Anti-theft protection for remote control KKF936A4 KKF910A4

Suction grille

Titanium apatite photocatalytic air-purification filter without frame KAF970A47 (1)

Photocatalytic deodorising filter, with frame

Photocatalytic deodorising filter, without frame

Air purification filter, with frame

Air purification filter, without frame

Notes

(1) Standard accessory

INDOOR UNITS - CONTROL SYSTEMS FTX20GV* FTX25GV* FTX35GV* FTXS20G FTXS25G

Wired remote control BRC944A2B (4)

Wiring adapter for time clock Normal open contact

Remote control Normal open pulse contact

Centralised control board Up to 5 rooms

Central remote control

Unified on/off control

Schedule timer

Interface adapter KRP980A1 (3)

Notes

(1) Wiring adapter supplied by Daikin. Time clock and other devices: to be purchased locally.

(2) Wiring adapter is also required for each indoor unit.

(3) For DIII-net adapter

(4) Only for Europe

INDOOR UNITS FTX20GV* FTX25GV* FTX35GV* FTXS20G FTXS25G

Anti-theft protection for remote control KKF917A4

Suction grille

Titanium apatite photocatalytic air-purification filter without frame KAF971A42 (1)

Notes

(1) Standard accessory

OUTDOOR UNITS RXR28E RXR42E RXR50E RX20GV* RX25GV* RX35GV* RXS20G RXS25G RXS35G

Air direction adjustment grille KPW937A4 KPW937B4 KPW937AA4

Drain plug KKP937A4 KKP937A4 KKP937A4 KPW9

Refrigerant branch piping for twin

Extension hose set for humidification (2m) KPMH942A402

Relay joint for humidification (10pcs.) KPMJ942A4

L-shape cuffs for humidification (10pcs) KPMH950A4L

Hose for humidification (10m)(l) KPMH942A42

Hose for humidification (15m)(l)

Branch provider (2 rooms)

Branch provider (3 rooms)

Options & Control Systems

282

Page 84: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

FTXG35J CTXG50J FDXS25E FDXS35E FDXS50C FDXS60C FVXS25F FVXS35F FVXS50F FLXS25B FLXS35B FLXS50B FLXS60B

BRC944B2(4)

KRP413AA1S (1) KRP413A1S (1) KRP413A1S (1) KRP413A1S (1) KRP413A1S (1)

KRP413AA1S (1) KRP413A1S (1) KRP413A1S (1) KRP413A1S (1) KRP413A1S (1)

KRC72A (2) KRC72A (2) KRC72A (2) KRC72A (2) KRC72A (2)

DCS302CA51 (4) DCS302CA51 (4) DCS302CA51 (4) DCS302CA51(4) DCS302CA51 (4)

DCS301BA51 (4) DCS301BA51 (4) DCS301BA51 (4) DCS301BA51(4) DCS301BA51 (4)

DST301BA51 (4) DST301BA51 (4) DST301BA51(4) DST301BA51(4) DST301BA51 (4)

KRP928BA2S (3) KRP928BA2S (3) KRP928BA2S (3) KRP928BA2S (3) KRP928BA2S (3)

FTXG35J* CTXG50J* FDXS25E FDXS35E FDXS50C FDXS60C FVXS25F FVXS35F FVXS50F FLXS25B FLXS35B FLXS50B FLXS60B

KKF910A4 KKF917AA4 KKF917AA4 KKF936A4 KKF917AA4

KDGF19A45 KDGF19A45

KAF968A42 (1)

KAZ917B41

KAZ917B42

KAF925B41

KAF925B42

FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G FTXL20G FTXL25G FTXL35G

BRC944B2 (4)

KRP413AA1S (1) KRP413AA1S (1)

KRP413AA1S (1) BRC944A2B (4)

KRC72A (2) KRC72A (2)

DCS302CA51 (4) DCS302CA51 (4)

DCS301BA51 (4) DCS301BA51 (4)

DST301BA51 (4) DST301BA51 (4)

KRP928BA2S (3) KRP928BA2S (3)

FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G FTXL20G FTXL25G FTXL35G

KKF910A4 KKF917A4 KKF910A4

KAF968A42 (1) KAF952B42 (1) KAF968A42 (1)

RXS42G RXS50G RXS60G RXS60F* RXS71F* RXL20G RXL25G RXL35G RXG25J RXG35J 3MXS/4MXS/5MXS 2MXU-G RMXS-EV

KPW945AA KPW45AA4 KPW945AA4 KPW937AA4 KPW945AA4 KPW937AA4 KKPW945AA4 KKPW945AA4

937AA4 KKP937A4 KKP945A4 KKP937A4 KKP937A4 KKPJF180

KHRQ22M20TA

KPMH996A10S

KPMH996A11S

BPMKS9672B2 BPMKS9672B2

BPMKS9673B3 BPMKS9673B3

��������� ���� ���������������������

��������� ���� ���������������������

��������� ���� ���������������������

��������� ���� ���������������������

283

Split

Page 85: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

INDOOR UNITS - CONTROL SYSTEMS FFQ25B FFQ35B FFQ50B FFQ60B FDQ125B FDQ200B FDQ250B FDBQ25B FBQ35C

Wired remote control BRC1DA528/BRC1E51A7 (9) BRC1D528/BRC1E51A7(9) BRC1D528/BRC1E51A7(9)

Infrared remote control (heat pump) BRC7E530W (10)

Simplified remote control

Remote control for hotel use

Centralised remote control DCS302CA51 (2) DCS302CA51 (2)

Unified ON/OFF control DCS301BA51 (2) DCS301BA51 (2)

Schedule timer DST301BA51 (2) DST301BA51 (2)

Adapter for wiring KRP1BA57 (4) KRP1BA54 (1)

Adapter for external ON/OFF and monitoring/for electrical appendices KRP4AA53 (4) KRP4AA51 (1)

Interface adapter for Sky Air® DTA112BA51 DTA112BA51

Installation box for adapter PCB KRP1BA101

Remote sensor KRCS01-1

Remote ON/OFF, forced OFF EKROROA EKROROA

Electrical box with earth terminal (3 blocks)

Electrical box with earth terminal (2 blocks)

Set back time clock

Intelligent touch controller

Remote control for 2 remote control systems

Adapter for wiring (hour meter) EKRP1B2A (5) EKRP1B2A (5)

Options PCB for external electrical heater, humidifier and/or hour meter EKRP1B2A (6)

External adapter for outdoor unit (installation on indoor unit)

Mounting plate for adapter PCB

Notes

(1) Installation box (KRP4AA93) for adapter PCB is necessary

(2) Interface adapter for Sky Air® series (DTA112BA51) is necessary

(3) Installation box for adapter PCB(KRP4A95) is necessary

(4) Installation box for adapter PCB (KRP1BA101) is necessary

(5) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.

(6) Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment.

(7) Mounting plate KRP4A96 is required fpr these options. Maximum 2 options PCBs can be mounted.

(8) Installations box is necessary for these adapters

(9) Included all the languages:English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish.

(10) For Europe

(11) If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for each indoor unit is required

INDOOR UNITS FFQ25B FFQ35B FFQ50B FFQ60B FDQ125B FDQ200B FDQ250B FDBQ25B FBQ35C FBQ50C

Replacement long-life filter KAFQ441BA60

Drain-up kit

Sealing member of air discharge outlet KDBH44BA60 BYBS45D

Decoration panel BYFQ60B

Decoration panel option

Fresh air intake kit (min. 20% fresh air) KDAJ25K56A

Fresh air intake kit (direct installation type) KDDQ44XA60

Panel spacer KDBQ44BA60

Notes(1) The BYCQ140CW1W has white insulations. Be informed that information of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140CW1W decoration panel in environments exposed to concentrations of dirt.(2) Decoration panel option EKBYBSD is required for direct mounting of the decoration panel of the unit.

Options & Control Systems

284

Page 86: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

FBQ50C FBQ60C FBQ71C FBQ100C FBQ125C FBQ140C FMDQ50B FMDQ60B FMDQ71B FMDQ100B FMDQ125B FVQ71B FVQ100B FVQ125B FAQ71B FAQ100B

BRC1D528/BRC1E51A7 (9) BRC1D528/BRC1E51A7 (9) BRC1D528/BRC1E51A7 (9)

BRC4C65 BRC4C65 BRC7EA618 BRC7CA510W

BRC2C51

BRC3A61

DCS302CA51 (2) DCS302CA51 DCS302CA51(2) DCS302CA51

DCS301BA51 (2) DCS301BA51 DCS301BA51(2) DCS301BA51

DST301BA51 (2) DST301BA51 DST301BA51(2) DST301BA51

KRP1BA54 (1) KRP1BA57 (3)

KRP4A51 (1) KRP2A51 (6) (7) (11) /KRP4A51 (7) (11) KRP4AA52 (3) KRP4AA51(1)

DTA112BA51 DTA112BA51 DTA112BA51

KRP1H98/KRPJ98 KRP4A95 KRP4AA93

KRCS01-4B KRCS01-1A

EKRORO3 EKROROA

KJB311A KJB311AA

KJB212A KJB212AA

BRC15A51

DCS601C51(2)

BRC1C61

EKRP1C11/KRP1C12 (8)

EKRP1B2A (6)(7) EKRP1B2A

DTA104A61 (6) (7) (11)

KRP4A96 KRP4A96

FBQ60C FBQ71C FBQ100C FBQ125C FBQ140C FMDQ50B FMDQ60B FMDQ71B FMDQ100B FMDQ125B FVQ71B FVQ100B FVQ125B FAQ71B FAQ100B

KAFJ95L160

K-KDU572CVE

BYBS71D BYBS125D

BYBS45D (2) BYBS71D (2) BYBS125D (2)

EKBYBSD

KDAJ25KA71A KDAJ25KA140A KDAJ25K56A KDAJ25K71A KDAJ25K140A

KEK26-1A

EKBYBSD

285

Page 87: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Options & Control Systems

INDOOR UNITS - CONTROL SYSTEMS FHQ35B FHQ50B FHQ60B FHQ71B FHQ100B FHQ125B FUQ71B FUQ100B FUQ125B

Wired remote control BRC1D528/BRC1E51A7 (6) BRC1D528/BRC1E51A7 (6)

Infrared remote control (heat pump) BRC7EA63W BRC7CA528W

Centralised remote control DCS302CA51 DCS302CA51

Unified ON/OFF control DCS301BA51 DCS301BA51

Schedule timer DST301BA51 DST301BA51

Adapter for wiring KRP1BA54

Adapter for external ON/OFF and monitoring/for electrical appendices KRP4AA52(1) KRP4AA53(1)

Interface adapter for Sky Air® DTA112BA51 DTA112BA51

Installation box for adapter PCB KRP1CA93 KRP1BA97

Remote sensor KRCS01-1A KRCS01-1A

Remote ON/OFF, forced OFF EKROROA EKROROA

Electrical box with earth terminal (3 blocks) KJB311AA KJB311AA

Electrical box with earth terminal (2 blocks) KJB212AA KJB212AA

Adapter for wiring (hour meter) EKRP1B2A

Notes

(1) Installation box for adapter PCB is necessary

(2) Interface adapter for Sky Air® series (DTA112BA51) is necessary

(3) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.

(4) Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment.

(5) Mounting plate KRP4A96 is required for these options. Maximum 2 options PCBs can be mounted.

(6) Included all the languages:English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish.

(7) For Europe

(8) Option not available in combination with BYCQ140CGW1

(9) When using decoration panel BYCQ140CGW1, wiring adapter (hour meter) KRP1C12 must be used

(10) When using decoration panel BYCQ140CGW1, installation box for adapter PCB KRP1J98 must be used

INDOOR UNITS FHQ35B FHQ50B FHQ60B FHQ71B FHQ100B FHQ125B FUQ71B FUQ100B FUQ125B

Replacement long-life filter KAFJ501DA56 KAFJ501DA80 KAF501DA80 KAF501DA112 KAF501DA160 KAF495FA140

Drain-up kit KDU50N60VE KDU50N125VE

L-type piping kit (upward direction) KHFP5MA35 KHFP5MA63 KHFP5MA160 KHFP49MA140

Sealing member of air discharge outlet KDBH49FA80 KDBH49FA140

Decoration panel for air discharge KDBT49FA80 KDBT49FA140

Vertical flap kit KDGJ49FA80 KDGJ49FA140

Decoration panel

Fresh air intake kit (min. 20% fresh air)

Notes(1) The BYCQ140CW1W has white insulations. Be informed that information of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140CW1W decoration panel in environments exposed to

concentrations of dirt.

(2) To be able to control the BYCQ140CGW1, the controller BRC1E* is needed

(3) The BYCQ140CGW1 is not compatible with mini-VRV®, multi and split non inverter outdoor units

(4) Option not available in combination with BYCQ140CGW1

OUTDOOR UNITS RZQ(S)71EV1/D* RZQ(S)100EV1/D* RZQ(S)125EV1/D* RZQ(S)140EV1/D*

Air direction adjustment grille EKDK04

Central drain plug

Refrigerant branch piping

For twin KHRQ22M20TA8 (KHRQ58T)(1)

For triple KHRQ127H8 (KHRQ58T)(1)

For double twin KHRQ22M20TA8(KHRQ58T)(x3)(1)

Demand adapter kit KRP58M51

Notes

(1) For RZQ100-140EW1 in combination FCQH71D8, use the refrigerant branch piping mentioned between brackets.

286

Page 88: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

FCQ35C8 FCQ50C8 FCQ60C8 FCQ71C8 FCQ100C8 FCQ125C8 FCQ140C8 FCQH71D8 FCQH100D8 FCQH125D8 FCQH140D8 FMCQ50A8 FMCQ60A8 FMCQ71A8 FMCQ100A8 FMCQ125A8

BRC1D528/BRC1E51A7(6) BRC1D528/BRC1E51A7(6) BRC1D528/BRC1E51A7(6)

BRC7F532F (8) BRC7F532F (8) BRC7F532F

DCS302CA51 DCS302CA51 DCS302CA51

DCS301BA51 DCS301BA51 DCS301BA51

DST301BA51 DST301BA51 DST301BA51

KRP1BA57/KRP4AA53 (1)(8) KRP1BA57/KRP4AA53 (1)(8) KRP1BA57/KRP4AA53 (1)(8)

KRP1H98/KRP1J98 (10) KRP1H98/KRP1J98 (10) KRP1H98/KRP1J98 (10)

KRCS01-4 KRCS01-4 KRCS01-4

EKRORO2 EKRORO2

KJB212AA KJB212AA KJB212AA

EKRP1C11/KRP1C12 (1)(9) EKRP1C11/KRP1C12 (1)(9) EKRP1C11/KRP1C12 (1)(9)

FCQ35C8 FCQ50C8 FCQ60C8 FCQ71C8 FCQ100C8 FCQ125C8 FCQ140C8 FCQH71D8 FCQH100D8 FCQH125D8 FCQH140D8 FMCQ50A8 FMCQ60A8 FMCQ71A8 FMCQ100A8 FMCQ125A8

KAFP551K160 KAFP551K160 KAFP551K160

KDBHQ55C140 KDBHQ55C140 KDBHQ55C140

BYCQ140CW1 + BYCQ140CW1W (1) + BYCQ140CGW1 (2)(3) BYCQ140CW1 + BYCQ140CW1W(1) + BYCQ140CGW1 (2)(3) BYCQ140CW1 + BYCQ140CW1W (1) + BYCQ140CGW1 (2)(3)

KDDQ55C140 (4) KDDQ55C140 (4) KDDQ55C140 (4)

RZQ100EW1* RZQ125EW1* RZQ140EW1* RZQ200C RZQ250C CMSQ200A CMSQ250A

EKDK04 KWC26B280 KWC26B160 KWC26B280

KHRQ22M20TA(KHRQ58T) (1) KHRQ22M20TA KHRQ22M29H

KHRQ127H8 (KHRQ58T) (1) KHRQ250H7 KHRQ22M20T KHRQ22M20T/KHRQ22M29T9

KHRQ127H8 (KHRQ58T) (x3) (1) KHRQ22M20TA(x3)

KRP58M51 KRP58M51

��������� ���� ���������������������

287

Page 89: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Options & accessories

VRV ® OUTDOOR UNITSVRVIII® heat recovery (high COP and small footprint combination)

VRV®-Q heat recovery

replacement VRV®

VRVIII® heat pump optimised

for heating

REYQ8P9 REYQ12P9 REMQ8P9 REMQ14-16P8REYQ18-

48P8/P9RQEQ-P RTSQ14P

REYQ10P8 REYQ14-16P8 REMQ10P8 REMQ12P9 REMHQ12P9 REYHQ16-24P RTSYQ10P RTSYQ16P RTSYQ20P

Cool/heat selector

Fixing box

REFNET header

KHRQ23M29H KHRQ23M29H KHRQ22M29H (8)

KHRQ23M64H KHRQ23M64H KHRQ22M64H

KHRQ23M75H KHRQ23M75H

REFNET joint

KHRQ23M20T KHRQ22M20T

KHRQ23M29T9 KHRQ22M29T9

KHRQ23M64T KHRQ23M64T KHRQ22M64T

KHRQ23M75T

Outdoor unit multi piping con-nection kit

For 2 outdoor units BHFQ23P907 BHFQ22P1007

For 3 outdoor units BHFQ23P1357

Central drain pan kit KWC25C450 (2) KWC26C280 (2) KWC26C450 (2)

Digital pressure gauge kit BHGP26A1(3)

Increase height difference between indoor & outdoor to 90m

BS Box for H/R BSVQ250P8B

Central BS Box for H/R BSV4Q100P8B

Sound reduction kit for BSVQ Box EKBSVQLNP (4)

BP Box for connection to stylish indoor units

Wind cover

Full set KPS25C450( 5) KPS26C280 (5) KPS26C504 (5)

Top/discharge KPS25C450T (5) KPS26C280T (5) KPS26C504T (5)

Rear/suction KPS25C450B (5) KPS26C280B (5) KPS26C504B (5)

Left/suction KPS26C504L(5)

Right/suction KPS26C504R (5)

Snowbreak hood

Kit (inlet + outlet) KPS26C280 (9) KPS26C504 (9) KPS26C280 (9)

Air outlet KPS26C280T (9) KPS26C504T (9) KPS26C280T (9)

Left side air inlet KPS26C504L (9) KPS26C504L (9)

Right side air inlet KPS26C504R (9) KPS26C504R (9)

Back side air inlet KPS26C280B (9) KPS26C504B (9) KPS26C280B (9)

VRV ® OUTDOOR UNITS VRV®-WIII standard series - heat recovery

RWEYQ8P RWEYQ10P RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P RWEYQ26P RWEYQ28P RWEYQ30P

Cool/heat selector

Fixing box KJB111A

REFNET header

KHRP25M33H (max. 8 branch)

KHRP25M72H (max. 8 branch)

KHRP25M73H (max. 8 branch)

REFNET joint

KHRP25A22T

KHRP25A33T

KHRP25A72T

Outdoor unit multi piping connection kitFor 2 outdoor units BHFP26MA56

For 3 outdoor units BHFP26MA84

Central drain pan kit KHRP25A73T

Strainer kitBWU26A15

BWU26A20

External control adapter for outdoor unit DTA104A62

Notes

(1) All options are kits

(2) Central drain pan kit shall be combined based on the outdoor multi connection table

(3) Only 1 option per installation is needed

(4) Only available for standard bsvq boxes (not possible for central BSVQ). Allows to reduce operating sound of BSVQ box (requires 1 sound kit per BSVQ box)

(5) Only required for technical cooling (outdoor temperature <5°C). For more information contact your local dealer

(6) 1 Option per module is required

(7) The option should be installed inside the outdoor unit, only needed in case outdoor unit is installed above indoor

(8) Ø 25.4 Gas pipe in KHRQ22M29H is not available for DENV refnet. This is only required for the 10HP model using size uo AND with an indoor connection ratio of less than 80%

(9) Snowbreak hoods are field supply. For technical drawings and more information contact your local Daikin dealer. Snowbreak hoods are advised to be installed when regular snowfall occurs.

288

Page 90: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

VRV® air cooled outdoor systems

VRVIII® heat pump (high COP and small footprint combination)VRVIII® heat pump with connection to stylish

indoor unitsVRV®III-S heat pump

VRV®-Q heat pump

replacement VRV®

RXYQ8PRXYQ20-54P(A)/

P8(A)

RXYQ5P RXYQ10P RXYQ12P RXYHQ12P8 RXYQ14-18P RXYHQ16-36P8 RXYQ8-10PR RXYQ12PR RXYQ14-18PRRXYSQ4PAV/

RXYSQ4PAY

RXYSQ5PAV/

RXYSQ5PAY

RXYSQ6PAV/

RXYSQ6PAYRQYQ-P

KRC19-26A6 KRC19-26A6 KRC19-26A6

KJB111A KJB111A KJB111A

KHRQ22M29H KHRQ22M29H KHRQ22M29H

KHRQ22M64H KHRQ22M64H

KHRQ22M75H

KHRQ22M20T KHRQ22M20T KHRQ22M20T

KHRQ22M29T9 KHRQ22M29T9

KHRQ22M64T KHRQ22M64T

KHRQ22M75T

BHFQ22P1007

BHFQ22P1517

KWC26B160 KWC26B280 KWC26B450 (2) KWC26B280 KWC26B450 KKPJ5F180

BHGP26A1 (3) BHGP26A1

EKLD90P12 EKLD90P18 (6/7)

BPMKS967B2

BPMKS967B3

Outdoor

VRV® water cooled outdoor systems

VRV®-WIII standard series - heat pumpVRV®-WIII geothermal series -

heat recovery

VRV®-WIII geothermal series -

heat pump

RWEYQ8P RWEYQ10P RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P RWEYQ26P RWEYQ28P RWEYQ30P RWEYQ8PR RWEYQ10PR RWEYQ8PR RWEYQ10PR

KRC19-26A KRC19-26A

KJB111A KJB111A KJB111A

KHRP26M33H (max. 8 branch) KHRP25M33H(max. 8 branch) KHRP26M33H(max. 8 branch)

KHRP26M72H (max. 8 branch)

KHRP26M73H (max. 8 branch)

KHRP26A22T KHRP25A22T KHRP26A22T

KHRP26A33T KHRP25A33T KHRP26A33T

KHRP2A72T

BHFP22MA56

BHFP22MA84

KHRP26A73T

BWU26A15 BWU26A15 BWU26A16

BWU26A20 BWU26A20 BWU26A21

DTA104A62 DTA104A62 DTA104A63

289

Page 91: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Options & accessories

FXFQ20-63P9 FXFQ80-125P9 FXZQ20-50M9 FXCQ20-32M8 FXCQ40-50M8 FXCQ63M8 FXCQ80-125M8

Decoration panel BYCQ140CW1 / BYCQ140CW1W (4)/ BYCQ140CGW1 (3) BYFQ60B BYBC32G BYBC50G BYBC63G BYBC125G

Decoration panel option

Replacement long life filter (non-woven type) KAFP551K160

Fresh air intake kit (20% fresh air intake)(chamber type) KDDQ55C140 (5)

Fresh air intake kit (direct installation type) KDDQ44XA60

Sealing member of air discharge outlet KDBHQ55C140 (3) KDBH44BA60

Panel spacer KDBH44B60

Replacement long life filter KAFQ441B60 KAFJ531G36 KAFJ531G56 KAFJ531G80 KAFJ531G160

High efficiency filter 65% KAFJ532G36 (1) KAFJ532G56 (1) KAFJ532G80 (1) KAFJ532G160 (1)

High efficiency filter 90% KAFJ533G36 (1) KAFJ533G56 (1) KAFJ533G80 (1) KAFJ533G160 (1)

Filter chamber for bottom suction KDDFJ53G36 KDDFJ53G56 KDDFJ53G80 KDDFJ53G160

Air discharge grille

Air discharge blind panel

Flexible duct (with shutter)

Insulation kit for high humidity

Air discharge adapter for round duct

FXMQ20-25-32P7 FXMQ40P7 FXMQ50-63P7 FXMQ80P7 FXMQ100-125P7 FXMQ200-250MA FXAQ20-63P FXHQ32MA

Decoration panel BYBS32D BYBS45D BYBS71D BYBS71D BYBS125D

Decoration panel option EKBYBSD

Sealing member of air discharge outlet

Replacement long life filter KAFJ371L280

High efficiency filter 65% KAFJ372L280

High efficiency filter 90% KAFJ373L280

Air discharge adapter for round duct KDAJ25K36A KDAJ25K56A KDAJ25K71A KDAJ25K140A

Drain pump kit KDU30L250VE K-KDU572EVE KDU50M60

Replacement long life filter (resin net) KAFJ501DA56

L-type piping kit (for upward direction) KHFP5M35

Air discharge decoration panel

Vertical flap kit

Notes:

(1) Filter chamber is required when installing a high efficiency filter

(2) To be able to control the BYCQ140CGW1, wired remote control BRC1E51A is needed

(3) BYCQ140CGW1 is not compatible with VRV®III-S

(4) The BYCQ140CW1W has white insulations. Be informed that information of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140CW1W decoration panel in environments exposed to

concentrations of dirt.

(5) Option not available in combination with BYCQ140CGW1

290

Page 92: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

FXKQ25-40MA FXKQ63MA FXDQ20-25M9 FXDQ20-32PB FXDQ40-50NB FXDQ63NB FXSQ20-32P FXSQ40-50P FXSQ63-80P FXSQ100-140P

BYK45F BYK71F BYBS32D BYBS45D BYBS71D BYBS125D

EKBYBSD

KPBJ52F56 KPBJ52F80

KAFJ521F56 KAFJ521F80

K-HV7AW K-HV9AW

KPBJ52F56W KPBJ52F80W

KFDJ52F56 KFDJ52F80

KDT25N32 KDT25N50 KDT25N63

KDAJ25KA36A KDAJ25KA56A KDAJ25KA71A KDAJ25KA140A

FXHQ63MA FXHQ100MA FXUQ71MA FXUQ100MA FXUQ125MA FXLQ20-25P FXLQ32-40P FXLQ50-63P FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA

KDBHJ49F80 KDBHJ49F140

KAFJ495F140 KAFJ361K28 KAFJ361K45 KAFJ361K71 KAFJ361K28 KAFJ361K45 KAFJ361K71 KAFJ361K28 KAFJ361K45 KAFJ361K71

KDU50M61 KDU50M125

KAFJ501DA80 KAFJ501DA112

KHFP5M63 KHFP5M63 KHFP49M63

KDBTJ49F80 KDBTJ49F140

KDGJ49F80 KDGJ49F140

291

Indoor

Page 93: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

OTHERS FXFQ FXZQ FXCQ FXKQ FXDQ-M9

Wiring adapter 6 KRP1B57 (1) KRP1B61 KRP1B61

Wiring adapter 7 EKRP1C11 / KRP1C12 (1) (9) EKRP1B2 EKRP1B2 (2)

Wiring adapter for electrical appendices (control and monitoring P1 P2) KRP2A526 (1) KRP2A52 (1) KRP2A51 (1) KRP2A61 KRP2A51

Wiring adapter for electrical appendices (control and monitoring F1 F2) KRP4AA53 (1) KRP4A53 (1) KRP4A51 (1) KRP4A51 KRP4A51

Remote sensor KRCS01-4 KRCS01-1 KRCS01-1 KRCS01-1 KRCS01-1

Installation box / mounting plate for adapter PCB KRP1H98 / KRP1J98 (10) KRP1BA101 KRP1B96 (4/5)

Electrical box with earth terminal (3 blocks) KJB311A KJB311A KJB311A KJB311A

Electrical box with earth terminal (2 blocks) KJB212A KJB212A KJB212A KJB212A KJB212A

Noise filter (for electromagnetic interface only) KEK26-1A KEK26-1A KEK26-1A KEK26-1A

External control adapter (for C/H zone, input LNO & Demand) DTA104A52 DTA104A51 (1) DTA104A61 DTA104A61

Interface adapter for Sky Air® series (to connect Sky Air® indoor to F1 F2)

Connector for forced on/forced off

Multi tenant option DTA114A61 (3) EKMTAC (11) EKMTAC (11)

Notes

(1) Installation box is required

(2) Fixing box is KRP1A90

(3) Mounting plate KRP4A96 is required. Maximum 2 option PCB can be mounted.

(4) Up to 2 adapters can be fixed per installation box

(5) Only 1 installation box can be installed per indoor unit

(6) For output 4 signals: Hour meter, fan, auxiliary electric heater, humidifier

(7) For output 2 signals: Hour meter, fan

(8) Option not available in combination with BYCQ140CGW1

(9) When using decoration panel BYCQ140CGW1, wiring adapter KRP1C12 must be used

(10) When using decoration panel BYCQ140CGW1, installation box KRP1J98 must be used

(11) This kit contains parts to connect with 10 multi tenant indoor units

INDIVIDUAL CONTROL SYSTEMS FXFQ FXZQ FXCQ FXKQ FXDQ-M9

Wired remote control BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52

Infrared remote control Heat pump BRC7F532F (8) BRC7E530 BRC7C62 BRC4C61 BRC4C62

Simplified remote control BRC2C51

Simplified remote control for hotel use BRC3A61

CENTRALISED CONTROL SYSTEMS FXFQ FXZQ FXCQ FXKQ FXDQ-M9

Centralised remote control DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51

Unified ON/OFF control DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51

Schedule timer DST301B51 DST301B51 DST301B51 DST301B51 DST301B51

Options & accessories

292

Page 94: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

FXDQ-PB FXDQ-NB FXSQ FXMQ-P7 FXMQ-MA FXAQ FXUQ FXHQ FXLQ FXNQ

KRP1B56 KRP1C64 (3) KRP1B61 KRP4A53 KRP1B3 KRP1B61 KRP1B61

EKRP1B2A (3) EKRP1B2A (3)

KRP2A53 KRP2A51 KRP2A51 (3) KRP2A61 KRP2A51 (1) KRP2A62 (1) KRP2A51 KRP2A51

KRP4A54 KRP4A51 KRP4A51 (3) KRP4A51 KRP4A51 (1) KRP4A52 (1) KRP4A51 KRP4A51

KRCS01-1 KRCS01-4 KRCS01-4 KRCS01-1 KRCS01-1 KRCS01-1 KRCS01-1 KRCS01-1 KRCS01-1

KRP1BA101 KRP4A96 (4/5) KRP4A96 (4/5) KRP4A93 (4/5) KRP1B97 KRP1C93 (4)

KJB311A KJB311A KJB311A KJB311A KJB311A KJB311A KJB311A KJB311A KJB311A

KJB212A KJB212A KJB212A KJB212A KJB212A KJB212A KJB212A KJB212A KJB212A

KEK26-1A KEK26-1A KEK26-1A KEK26-1A KEK26-1A KEK26-1A KEK26-1A KEK26-1A

DTA104A53 DTA104A61 DTA104A61 DTA104A61 DTA104A61 DTA104A62 DTA104A61 DTA104A61

DTA102A52

EKRORO

EKMTAC (11) DTA114A61 (3) DTA114A61 DTA114A61

FXDQ-PB FXDQ-NB FXSQ FXMQ-P7 FXMQ-MA FXAQ FXUQ FXHQ FXLQ FXNQ

BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52

BRC4C62 BRC4C65 BRC4C66 BRC4C65 BRC7E618 BRC7C528 BRC7E63 BRC4C62 BRC4C62

BRC2C51 BRC2C51 BRC2C51 BRC2C51 BRC2C51 BRC2C51

BRC3A61 BRC3A61 BRC3A61 BRC3A61 BRC3A61 BRC3A61

FXDQ-PB FXDQ-NB FXSQ FXMQ-P7 FXMQ-MA FXAQ FXUQ FXHQ FXLQ FXNQ

DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51

DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51

DST301B51 DST301B51 DST301B51 DST301B51 DST301B51 DST301B51 DST301B51 DST301B51 DST301B51

293

Indoor

Page 95: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

OTHERS VAM-FA VKM-GA(M)

Wiring adapter for electrical appendices (control and monitoring P1 P2) KRP2A61 KRP2A61

Wiring adapter for electrical appendices (control and monitoring F1 F2)

Adapter for humidifier (running ON signal output) KRP50-2 KRP50-2

Adapter for heater control kit BRP4A50 BRP4A50

Remote sensor

Notes

(1) Cool/heat selector required for operation

(2) Do not connect the system to DIII-net devices (Intelligent controller, Intelligent Manager, LonWorks interface, BACnet interface…).

OTHERS VAM150FA VAM250FA VAM350FA VAM500FA VAM650FA VAM800FA VAM1000FA

High efficiency filter

YAFM323F15 YAFM323F25 YAFM323F35 YAFM323F50 YAFM323F65 YAFM323F100

-65%

-90%

Replacement air filter YAFF323F15 YAFF323F25 YAFF323F35 YAFF323F50 YAFF323F65 YAFF323F100

Replacement long life filter

Filter chamber (1)

SilencerKDDM24A50 KDDM24A100 KDDM24A100

Nom. piping diameter ø200mm ø250mmm

Duct adapterNom. piping diameter

Drain pump kit

Adapter for wiring

Central drain pan

Central drain plug

Cool/heat selector

Fixing box

Notes

(1) Filter chamber has a suction-type flange. (Main unit does not).

Some options may not be usable due to the equipment installations conditions. Please conrfirm prior to ordering.

Some options may not be used in combination.

Operating sound may increase somewhat depending on the options used.

INDIVIDUAL CONTROL SYSTEMS VAM-FA VKM-GA(M)

Wired remote control BRC1E51A / BRC1D52 BRC1E51A / BRC1D52

VAM wired remote control BRC301B61 BRC301B61

CENTRALISED CONTROL SYSTEMS VAM-FA VKM-GA(M)

Centralised remote control DCS302C51 DCS302C51

Unified ON/OFF control DCS301B51 DCS301B51

Schedule timer DST301B51 DST301B51

Options & accessories

294

Page 96: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

FXMQ-MF EKEQDCB (2) EKEQDCB (2) EKEQMCB (2)

KRP2A61

KRP4A51 KRP4A51

KRCS01-1

VAM1500FA VAM2000FA VKM50GA(M) VKM80-100GA(M) FXMQ125MF FXMQ200-250MF ERQ100-125AV1 ERW140AV1 ERQ125AW1 ERQ200-250AW1

YAFM323F65X2 YAFM323F100X2 KAF241G80M KAF241G100M

KAFJ372L140 KAFJ372L280

KAFJ373L140 KAFJ373L280

YAFF323F65X2 YAFF323F100X2 KAF242G80M KAF242G100M

KAFJ371L140 KAFJ371L280

KDJ3705L140 KDJ3705L280

KDDM24A100X2 KDDM24B100

ø250mm ø250mm

YDFA25A1

ø250mm

KDU30L250VE

KRP1B61

KWC26B160 KWC26B280

KKPJ5F180 KKPJ5F180

KRC19-26A6

KJB111A

FXMQ-MF EKEQDCB (2) EKEQDCB (2) EKEQMCB (2)

BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 BRC1E51A / BRC1D52 (1) BRC1E51A / BRC1D52 (1)

FXMQ-MF EKEQDCB (2) EKEQDCB (2) EKEQMCB (2)

DCS302C51

DCS301B51

DST301B51

295

Ventilation

Page 97: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Options

Option Combination & Exceptions:

/A High Efficiency Unit

/Q Standard Efficiency Unit, Extra Low Noise

/H High Ambient Unit

/S Inverter Unit

/X Seasonal High Efficiency Inverter Unit

A/C Air Cooled

W/C Water Cooled

C/F Centrifugal Fan

C/C Condenserless Chiller

Cooling Only

Heating Only

Heat Pump

(1) Unit Length Increase By 230mm

(2) Unit Length Increase By 310mm

(3) Not Available With Option OPLN

(4) High Pressure Side Gauge

(5) Only for SL, XL & PL versions

(6) OPLR Liquid Receiver option available

(7) EKRP1HB option kit available

(8) Footprint could increase

(9) Possible incompatability with pumps. Contact factory.

Type Compr. Refr Mode Reference Products

Integrated Hydronics Noise & Head

Single

pump

contact

Twin

pump

contact

Single

pump

Twin

pump

High ESP

pump

High

ESP twin

pump

Buffer

tank

Reduced

Noise

Low

noise

Inverter

fans

OPSC OPTC OPSP OPTP OPHP OPHT OPBT OPRN OPLN OPIF

A/C

SWING R-410AEWAQ-ACV3P 005-006-007 STD

EWYQ-ACV3P 005-006-007 STD

SCROLL

R-410A

EWAQ-ACV3 (7) 009-010-011 STD

EWAQ-ACW1 (7) 009-011-013 STD

EWYQ-ACV3 (7) 009-010-011 STD

EWYQ-ACW1 (7) 009-011-013 STD

R-407C

EUWAC-FZW 5-8-10

EUWAN-KAZW 5-8-10-12-16-20-24

EUWAP-KAZW 5-8-10-12-16-20-24 •

EUWAB-KAZW 5-8-10-12-16-20-24 • STD

EUWYN-KAZW 5-8-10-12-16-20-24

EUWYP-KAZW 5-8-10-12-16-20-24 •

EUWYB-KAZW 5-8-10-12-16-20-24 • STD

R-410AEWAQ-DAYNN 080-100-130-150-180-210-240-260 • • • • • • • •(3)

EWYQ-DAYNN 080-100-130-150-180-210-230-250 • • • • • • • •(3)

SCREW R-134a

EWAD-MBYNN120-150-170-240-300-340 •

380-460-520-600 • •

EWAD-AJYNN

190-200 •(1) •(2)(3) •(1) •(2)(3) •

230-260-280-300-320-340-360 • • • • •

400 • • • •

440-480-500-550-600 • • • • •(3) •

EWAD-AJYNN / A260-280-320-340-360-380-420 • • • • •

500-550-600-650 • • • • •

EWAD-AJYNN / Q210-240-260-280-300-320-340

400-440-460-500

EWAD-AJYNN / H

200-210 •(1) •(2)(3) •(1) •(2)(3)

240-260-280-300-320-340-400 • • • •

420-460-480-500-550-600 • • • •

EWAD-AJYNN/S 330-360-400-420-460-490-520 • • • • •(3)

EWAD-AJYNN/X 330-360-400-420-460-490-520 • • • • •(3) •

EWYD-BZSS 250-270-290-320-340-370-380-410-440-460-510-520-580 • • • •

EWYD-BZSL 250-270-290-320-330-360-370-400-430-450-490-510-570 STD

EWAD-C-SS/SL 650-740-830-910-970-C11-C12-C14-C15-C16-C17 • • STD (5)

EWAD-C-SR 620-720-790-880-920-C10-C11-C13-C14-C15-C16 • • • STD

EWAD-C-XS/XL 760-830-890-990-C10-C11-C12-C13-C14-C15-C16-C17-C18-C19 • • STD (5)

EWAD-C-XR 740-810-870-970-C10-C11-C12-C13-C14-C15-C16-C17-C18-C19 • • • STD

EWAD-C-PS/PL 820-890-980-C11-C12-C13-C14 • • STD (5)

EWAD-C-PR 810-880-960-C10-C11-C13-C14 • • STD

W/C

SCROLL R-407CEWWP-KAW1N 014-022-028-035-045-055-065

EWWP-KAW1M 045-055-065

SCREW

R-134a

EWWD-MBYNN 120-180-240-280-360-440-500-520-540 •

EWWD-DJYNN 170-210-260-300-320-380-420-460-500-600 •

EWWD-DJYNN / A190-230-280-320-380-400-460-500 •

550-650 •

EWWD-EJYNN (6)340-400-460-550-650-700-800-850-900-950-C10-C12-C13-C14-C15-C16-C17-C18

EWWD-EJYNN/A (6) 360-440-500-600-750-800-850-950-C10-C11-C12

EWWD-BJYNN 380-460-550-750-850-900-C10-C11

R-410a

EWWQ-AJYNN400-480-600-650-750-800-850-900-C10-C11-C12-C13-C14-C15-C16-C17-C18-C19-C20

EWWQ-AJYNN / A440-550-650-750-800-950-C10-C11-C12-C13-C14-C15-C16-C18-C19-C20-C22

C/C

SCROLL R-407C EWLP-KAW1N 012-020-026-030-040-055-065

SCREW R-134a

EWLD-MBYNN 120-170-240-260-340-400-480-500-540 •

EWLD-DJYNN (6) 160-190-240-280-320-360-380-420-480-550 •

EWLD-EJYNN (6)320-400-420-500-600-650-750-800-850-900-950- C10-C11-C12-C12-C14-C15-C16-C17

296

Page 98: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Pressure Control Heat Recovery LWE Electrical Refrigerant Condenser Misc

Fan

Silent

Low

Ambient

High ESP

fans

Total

Heat

Recovery

Partial

Heat

Recovery

High

Glycol

Low

Glycol

Evaporator

heater tape

Main

switch

Soft

starter

Power

factor

0,9

A / V

meter

Address

card

No

switchbox

Electronic

Expansion

Valve

Dual

pressure

relief valve

Suction

stop

valve

GaugesCoil

guards

Blank

Cu / Al

coils

Cu / Sn

coils

Cu / Cu

coils

Cu / Ni

heat

exchanger

Spring Anti

Vibration

Mounts

OPFS OPLA OPHF OPTR OPPR OPZH OPZL OP10 OP52 OPSS OPPF OP57 OPAC OPNS OPEX OP03 OP12 OPGA OPCG OPAL OPSN OPCU OPNI OPSVM

• •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • STD • •(s) •(s) •

• • STD • •(s) •(s) •

• STD • • •(s) •(s) •

• STD • • •(s) •(s) •

• • •(8)(9) • STD STD STD STD • • •(s) STD •(4) • • • • •

• • •(8)(9) • STD STD STD STD • • •(s) STD •(4) • • • • •

• • •(8)(9) • STD STD STD STD • • • •(s) STD •(4) • • • • •

• • •(8)(9) • STD STD STD STD • • • •(s) STD •(4) • • • • •

• • •(8)(9) • STD STD STD STD • • •(s) STD •(4) • • • • •

• • •(8)(9) • STD STD STD STD • • • •(s) STD •(4) • • • • •

STD •(8)(9) • STD STD STD STD • • •(s) STD •(4) • • • • •

STD •(8)(9) • STD STD STD STD • • • •(s) STD •(4) • • • • •

• • •(8)(9) • STD STD STD STD • • •(s) STD •(4) • • • • •

• • •(8)(9) • STD STD STD STD • • •(s) STD •(4) • • • • •

• • •(8)(9) • STD STD STD STD • • • •(s) STD •(4) • • • • •

•(8)(9) • STD STD STD STD STD •(s) STD •(4) • • • • •

•(8)(9) • STD STD STD STD STD •(s) STD •(4) • • • • •

• • • • STD STD STD •(s) STD •(4) • • • • •

• • • STD STD STD •(s) STD •(4) • • • • •

• •(9) • • • STD STD • • • STD STD •(s) •(4) • • • • •

• •(9) • • • STD STD • • • STD STD •(s) •(4) • • • • •

• •(9) • • • STD STD • • • STD STD •(s) •(4) • • • • •

• •(9) • • • STD STD • • • STD STD •(s) •(4) • • • • •

• •(9) • • • STD STD • • • STD STD •(s) •(4) • • • • •

• •(9) • • • STD STD • • • STD STD •(s) •(4) • • • • •

• •

• • STD

• • •(s) •(s)

• • STD STD STD • • • STD •(s) STD STD •

• • STD STD STD • • • STD •(s) STD STD •

• • STD STD STD • • • STD •(s) STD STD •

• • STD STD STD • • • STD •(s) •(s) STD •

• • STD STD STD • • • STD •(s) •(s) STD •

• STD STD STD • • • STD •(s) •(s) STD •

• STD STD STD • • • STD •(s) •(s) STD •

• STD • • • STD •(s) •(s) STD •

• STD STD STD • • • STD •(s) •(s) STD •

• STD STD STD • • • STD •(s) •(s) STD •

• STD STD STD • • • STD •(s) •(s) STD •

• STD STD STD • • • STD •(s) •(s) STD •

• •

• • •(s) •(s)

• STD STD STD • • • STD •(s) •(s) STD

STD STD STD • • • STD •(s) •(s) STD

STD STD STD • • • STD •(s) •(s) STD

(s) OP12 & OP03 need to be added to meet Swedish national law 1992: 16

Applied systems

297

Page 99: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Type Compr. Refr. Mode Reference

GaugesSoft

starterCommunication cards

LON

gateway

Modbus gateway

Bacnet gateway

EK

GA

U5

/8K

A

EK

GA

U1

0/1

2K

A

EK

GA

U1

6K

A

EK

GA

U2

0/2

4K

A

EK

GA

U2

5/3

0H

EK

SS

EK

AC

10

B

EK

AC

30

A

EK

AC

20

0A

EK

AC

20

0J

EK

AC

PG

EK

AC

BA

C

EK

AC

LO

N

EK

LO

NP

G

EK

BM

SM

BA

EK

BM

SB

NA

EK

BN

PG

EK

BM

SB

NJ

EK

RU

MC

EK

RU

PC

A/C

SWING R-410AEWAQ005-007ACV3

EWYQ005-007ACV3

SCROLL

R-410A

EWAQ009-011ACV3

EWAQ009-013ACW1

EWYQ009-011ACV3

EWYQ009-013ACW1

R-407C

EUWAC5-8-10FZW • •(1) •(1) •(1)

EUWAN5-8KAZW • • • •(1) •(1) •(1)

EUWAN10-12KAZW • • • •(1) •(1) •(1)

EUWAN16KAZW • • •(1) •(1) •(1)

EUWAN20-24KAZW • • •(1) •(1) •(1)

EUWAP5-8KAZW • • • •(1) •(1) •(1)

EUWAP10-12KAZW • • • •(1) •(1) •(1)

EUWAP16KAZW • • •(1) •(1) •(1)

EUWAP20-24KAZW • • •(1) •(1) •(1)

EUWAB5-8KAZW • • • •(1) •(1) •(1)

EUWAB10-12KAZW • • • •(1) •(1) •(1)

EUWAB16KAZW • • •(1) •(1) •(1)

EUWAB20-24KAZW • • •(1) •(1) •(1)

EUWYN5-8KAZW • • • •(1) •(1) •(1)

EUWYN10-12KAZW • • • •(1) •(1) •(1)

EUWYN16KAZW • • •(1) •(1) •(1)

EUWYN20-24KAZW • • •(1) •(1) •(1)

EUWYP5-8KAZW • • • •(1) •(1) •(1)

EUWYP10-12KAZW • • • •(1) •(1) •(1)

EUWYP16KAZW • • •(1) •(1) •(1)

EUWYP20-24KAZW • • •(1) •(1) •(1)

EUWYB5-8KAZW • • • •(1) •(1) •(1)

EUWYB10-12KAZW • • • •(1) •(1) •(1)

EUWYB16KAZW • • •(1) •(1) •(1)

EUWYB20-24KAZW • • •(1) •(1) •(1)

R-410A

EWAQ080-210DAYNN • • •

EWAQ240-260DAYNN • • •

EWYQ080-210DAYNN • • •

EWYQ230-250DAYNN • • •

SCREW R-134a

EWAD120-600MBYNN • •(2) •(2) •

EWAD190-600AJYNN • • •

EWAD260-650AJYNN/A • • •

EWAD210-500AJYNN/Q • • •

EWAD200-600AJYNN/H • • •

EWAD330-520AJYNN/S • • •

EWAD330-520AJYNN/X • • •

ChillerAccessories

(1) To install EKBMSMBA, EKBMSBNA and EKRUMC, EKAC10B needs to be installed on the unit.

(2) To install EKBMSMBA and EKBMSBNA, EKAC200A needs to be installed on the unit.

(3) (2 pieces are needed)

(4) Including WRC-COA / WRC-HPA

(5) only available for cooling only application

298

Page 100: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Remote user

interfaceBuffer tanks

Com-

mon

leaving

water

sensor

Plant

VisorModem

Conver-

ter

RS485

to

RS232

Conver-

ter

RS485

to USB

Waterpipe Kit Hydraulic module Low noise kit Switch box

EK

RU

PG

EK

RU

PC

J

EK

RU

PC

K

EK

BT

EK

BT

50

0N

EK

BT

C1

0N

EK

BT

50

0C

EK

BT

C1

0C

EK

CLW

S

EK

PV

2J

EK

MO

DE

M

EK

GS

MO

D

EK

CO

N

EK

CO

NU

SB

EK

GN

21

0

EK

GN

26

0

EH

MC

10

A1

0

EH

MC

10

A8

0

EH

MC

15

A1

0

EH

MC

15

A8

0

EH

MC

30

A1

0

EH

MC

30

A8

0

EK

LS

1

EK

LS

2

EC

B1

MU

W

EC

B2

MU

W

EC

B3

MU

W

• •

• •

• •

• •

• •

• • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

Applied systems

299

Page 101: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Type: FWM, FWL, FWV1 2 3 4 6 8 10 FWV FWL FWM

Description

Additional single row heat exchanger ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6 x x x

Electric heater EEH01A6 EEH02A6 EEH03A6 EEH06A6 EEH10A6 x x x

2-pipe 3-way valve E2MV03A6 E2MV06A6 E2MV10A6 x x x

4-pipe 3-way valve E4MV03A6 E4MV06A6 E4MV10A6 x x x

Fan stop thermostat YFSTA6 x x x

Air intake & discharge grille EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6 - - x

Supporting feet ESFV06A6 ESFV10A6 x - x

Supporting feet � grille ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6 x - -

Fresh air intake EFA02A6 EFA03A6 EFA06A6 EFA10A6 x x x

Rear panel ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6 x x -

Control electromechanical ECFWMB6 x x -

Electronic controller - on board FWEC1A, FWEC2A, FWEC3A x x -

Electronic controller - remote FWEC1A, FWEC2A, FWEC3A x x x

Master slave option EPIMSA6 x x x

Vertical drainpan EDPVA6 x x x

Horizontal drainpan EDPHA6 - x x

On board installation kit FWECKA x x x

Temperature sensor kit FWTSKA x x x

Relative humidity sensor kit FWHSKA x x x

Type: FWT, FWF and FWCFWT FWC FWF

Description

Standard wired remote control MERCA

Simplified wired remote control SRC-COA

Simplified wired remote control SRC-HPA

2-pipe 3-way valve - - MCKCW2T3VN

2-pipe 3-way valve - MCKAW2T3VN -

4-pipe 3-way valve - MCKAWH4T3VN -

Wireless control for cooling only WRC-COB

Wireless control for heat pump WRC-HPB

Decoration panel 900 x 900 2-pipe (4) - DCP900TB -

Decoration panel 900 x 900 4-pipe (4) - DCP900FB -

Decoration panel 600x600 - - DCP600TB

Fan coil

(1) To install EKBMSMBA, EKBMSBNA and EKRUMC, EKAC10B needs to be installed on the unit.

(2) To install EKBMSMBA and EKBMSBNA, EKAC200A needs to be installed on the unit.

(3) (2 pieces are needed)

(4) Including WRC-COA / WRC-HPA

Type Compr. Refr. Mode Reference

GaugesSoft

starterCommunication cards

LON

gateway

Modbus gateway

Bacnet gateway

EK

GA

U5

/8K

A

EK

GA

U1

0/1

2K

A

EK

GA

U1

6K

A

EK

GA

U2

0/2

4K

A

EK

GA

U2

5/3

0H

EK

SS

EK

AC

10

B

EK

AC

30

A

EK

AC

20

0A

EK

AC

20

0J

EK

AC

PG

EK

AC

BA

C

EK

AC

LO

N

EK

LO

NP

G

EK

BM

SM

BA

EK

BM

SB

NA

EK

BN

PG

EK

BM

SB

NJ

EK

RU

MC

EK

RU

PC

W/C

SCROLL R-407C

EWWP014KAW1N • • •(1) •(1) •(1)

EWWP022KAW1N • • •(1) •(1) •(1)

EWWP028KAW1N • • •(1) •(1) •(1)

EWWP035KAW1N • • •(1) •(1) •(1)

EWWP045KAW1N • •(1) •(1) •(1)

EWWP055-065KAW1N • •(1) •(1) •(1)

EWWP045-055-065KAW1M

SCREW

R-134a

EWWD120-540MBYNN • •(2) •(2) •

EWWD170-600DJYNN • • •

EWWD190-650DJYNN/A • • •

EWWD340-C18EJYNN • • •

EWWD360-C12EJYNN/A • • •

EWWD380-C11BJYNN • • •

R-410AEWWQ400-C20AJYNNEWWQ440-C22AJYNN/A

• • •

• • •

C/C

SCROLL R-407C

EWLP012KAW1N • • •(1) •(1) •(1)

EWLP020KAW1N • • •(1) •(1) •(1)

EWLP026KAW1N • • •(1) •(1) •(1)

EWLP030KAW1N • • •(1) •(1) •(1)

EWLP040KAW1N • •(1) •(1) •(1)

EWLP055-065KAW1N • •(1) •(1) •(1)

SCREW R-134a

EWLD120-540MBYNN • •(2) •(2) •

EWLD160-550DJYNN • • •

EWLD320-C17EJYNN • • •

ChillerAccessories

300

Page 102: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Remote user interface Buffer tanks

Com-

mon

leaving

water

sensor

Plant

VisorModem

Conver-

ter

RS485

to

RS232

Conver-

ter

RS485

to USB

Waterpipe Kit Hydraulic module Low noise kit Switch box

EK

RU

PG

EK

RU

PC

J

EK

RU

PC

K

EK

BT

EK

BT

50

0N

EK

BT

C1

0N

EK

BT

50

0C

EK

BT

C1

0C

EK

CLW

S

EK

PV

2J

EK

MO

DE

M

EK

GS

MO

D

EK

CO

N

EK

CO

NU

SB

EK

GN

21

0

EK

GN

26

0

EH

MC

10

A1

0

EH

MC

10

A8

0

EH

MC

15

A1

0

EH

MC

15

A8

0

EH

MC

30

A1

0

EH

MC

30

A8

0

EK

LS

1

EK

LS

2

EC

B1

MU

W

EC

B2

MU

W

EC

B3

MU

W

• • •

• • •

• • • • •

• • •

• • • • • (3)

• • • (3)

• • •

• • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • •

• • •

• • • • •

• • •

• • • • • (3)

• • • (3)

• • • • •

• • • • • • • • • •

• • • • • • • • • •

Type: FWD4 6 8 10 12 16 18

Description

Electric heater: small EDEH04A6 EDEHS06A6 EDEHS10A6 EDEHS12A6 EDEHS18A6

Electric heater: big EDEH04A6 EDEHB06A6 EDEHB10A6 EDEHB12A6 EDEHB18A6

2-pipe 3-way valve ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6

4-pipe 3-way valve ED4MV04A6 ED4MV10A6 2xED2MV12A6 2 x ED2MV18A6

Vertical Drainpan EDDPV10A6 EDDPV18A6

Horizontal Drainpan EDDPH10A6 EDDPH18A6

Fan stop thermostat YFSTA6

Fresh air intake EDMFA04A6 EDMFA06A6 EDMFA10A6 EDMFA12A6 EDMFA18A6

Electronic controller - remote FWEC1A, FWEC2A, FWEC3A

Power interface - EPIB6

Master slave interface EPIMSA6 -

On board installation kit FWECKA

Temperature sensor kit FWTSKA

Relative humidity sensor kit FWHSKA

Type: FWB-A2-4 5-7 8-10

Description

Additional heat exchanger EAH04A6 EAH07A6 EAH10A6

3-way valve add. h/e E2MV307A6 E2MV310A6

2-way valve add. h/e E2MV207A6 E2MV210A6

Electric Heater Factory mounted

Fan stop thermostat YFSTA6

Power interface - EPIB6

Master slave interface EPIMSA6

Electronic controller - remote FWEC1A, FWEC2A, FWEC3A

On board installation kit FWECKA

Temperature sensor kit FWTSKA

Relative humidity sensor kit FWHSKA

Type: FWB-J

Description

2-pipe 3-way valve MCWCN

4-pipe 3-way valve MCWHN

Applied systems

301

Page 103: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

HEATING & COOLING1) nominal cooling capacities are based on:Indoor temperature 27°CDB/19°CWBOutdoor temperature 35°CDBRefrigerant piping length 7.5m - 8/5m VRV®

Level difference 0m2) nominal heating capacities are based on:Indoor temperature 20°CDBOutdoor temperature 7°CDB/6°CWBRefrigerant piping length 7.5m - 8/5m VRV®

Level difference 0m

APPLIED SYSTEMSAir-cooled Cooling only Evaporator: 12°C/7°C Ambient: 35°CDB

Heat pump Evaporator: 12°C/7°C Ambient: 35°CCondenser: 40°C/45°C Ambient: 7°CDB/6°CWB

Water-cooled Cooling only Evaporator: 12°C/7°CCondenser: 30°C/35°C

Heating only Evaporator: 12°C/7°CCondenser: 40°C/45°C

Condenserless chiller Evaporator: 12°C/7°CCondensing temperature: 45°C / liquid temperature: 40°C

Fan coil units Cooling Room temperature: 27°C/19°CEntering water temperature: 7°C/12°C

Heating Room temperature: 20°CWater inlet temperature: 50°C (2-pipe)/70°C (4-pipe)

)!+��,-))./

012%�#���3#��453121�#���6�$�3#��453�21�#���6�$�37���3#��457(�45�3%21�#�%�3#��453821�#�����$�37�����%�3#��457(�45+12%��#$��3#��45/12%�#$��3#��45

8�9,-�;�<�!�=;0;!�,

�>��3���?���@��������1�#���6�$�3#��45������������������B�� �����@�F

0B���@�������@����J��������@���J����� ���B������ ������������ ������B�@���F;����������J�J��@�#�����������B������� ����� �@��� ��J��������K�������@��� ������������������������B��� B�� ������M��P�QF0B���@����?����J�������M���@��J��@����� �����B�V��?��W?B� B���@����@� ���������F>������������������������������� ���@���@��� B�� ������M��P�F

���

Page 104: CHILLERS - Начало: СОФКЛИМА БГ ФИРМА ЗА ... Daikin 2010 EN... · 2013-10-24 · EUWA*5-24KAZW EUWY*5-24KAZW R-410A EWAQ080-260DAYN EWYQ080-250DAYN SCREW R-134a

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

PRELIMINARY

emura

GE

NE

RA

L C

AT

AL

OG

UE

20

10

CLIMATE COMFORTAll seasons

Heating

Air conditioning

Applied Systems

Refrigeration

2010General

EC

PE

N1

0-5

00

_P

• C

D •

10

/09

• C

op

yrig

ht

Da

ikin

Th

e p

rese

nt

pu

blic

ati

on

su

pe

rse

de

s E

CP

EN

09

-50

0

Pri

nte

d in

Be

lgiu

m b

y La

nn

oo

(w

ww

.lan

no

op

rin

t.b

e),

a co

mp

any

wh

ose

co

nce

rn

for

the

en

viro

nm

en

t is

se

t in

th

e E

MA

S an

d IS

O 1

40

01

sys

tem

s.

Re

spo

nsi

ble

ed

ito

r: D

aik

in E

uro

pe

N.V

., Z

an

dvo

ord

est

raa

t 3

00

, B-8

40

0 O

ost

en

deThe present leaflet is drawn up by way of information only and does not constitute an offer binding upon

Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge.

No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular

purpose of its content and the products and services presented therein. Specifications are subject to change

without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in

the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is

copyrighted by Daikin Europe N.V.

Daikin Europe N.V. participates in the Eurovent Certification

Programme for Air Conditioners (AC), Liquid Chilling

Packages (LCP) and Fan Coil Units (FC); the certified data of

certified models are listed in the Eurovent Directory. Multi

units are Eurovent certified for combinations up to 2

indoor units.

Daikin’s unique position as a manufacturer of air

conditioning equipment, compressors and refrigerants

has led to its close involvement in environmental issues.

For several years Daikin has had the intention to become

a leader in the provision of products that have limited

impact on the environment. This challenge demands

the eco design and development of a wide range

of products and an energy management system,

resulting in energy conservation and a reduction of

waste. Daikin products are distributed by:

������������

Introducing Daikin Emura.

Designed in Europe for European climates, it ’s an

inspired new look at air conditioning.

Blending iconic design and engineering excellence,

it will be loved by anyone who wants their home

to look beautiful and feel comfortable.

www.daikinemura.eu

FORM. FUNCTION. REDEFINED.