1 Design Features Elegant design The design, elegant and considered in all details , harmonizes well with all type of interiors C-shape Coil The unit is equipped with C-shape coil, big exchange area, distribute air equally, high efficiency. Quite centrifugal fan Quite centrifugal fan, with ABS fan wheel, high efficiency and low noise. Service-Friendly Manual Air Vent Air vent hand valve is conveniently located over the drain pan and does not require any tools to vent the coil High quality drain pump Unit ship standard with high quality drain pump , 0.7m liſt high. Fresh air and branch air duct connection Prepared fresh air duct and branch air duct interface customers can seet the convenience to connect fresh air and branch air duct at site. P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low noise, suitable for office building, meeting room, and restaurant. Units are standard supplied with remote controller, drain pump and nylon filter. Introduction www.innovair.com Chilled Water 4-Way Ceiling Cassette CW Series

Transcript of Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use...

Page 1: Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low

1

Design FeaturesElegant designThe design, elegant and considered in all details , harmonizes well with all type of interiors

C-shape CoilThe unit is equipped with C-shape coil, big exchange area, distribute air equally, high efficiency.

Quite centrifugal fanQuite centrifugal fan, with ABS fan wheel, high efficiency and low noise.

Service-Friendly Manual Air VentAir vent hand valve is conveniently located over the drain pan and does not require any tools to vent the coil

High quality drain pumpUnit ship standard with high quality drain pump , 0.7m lift high.

Fresh air and branch air duct connectionPrepared fresh air duct and branch air duct interface customers can seet the convenience to connect fresh air and branch air duct at site.

P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low noise, suitable for office building, meeting room, and restaurant.Units are standard supplied with remote controller, drain pump and nylon filter.

Introduction

www.innovair.com

Chilled Water4-Way Ceiling Cassette

CW Series

Page 2: Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low

2www.innovair.com

General Data

Performance DateThe performance data lists regular EU stendard, ARI 440 standard and District Cooling. For more conditions, please refer to our selection software.1. Standard ratingThe following rating conditions are used:Cooling:Entering air temperature: +27℃DB; +19.5℃WBWater inlet/outlet: ++7/12℃

Heating:Entering air temperature: +20℃DBWater inlet temperature: +50℃Water flow rate as for the cooling conditions.

Spec CW4-003 CW4-004 CW4-005 CW4-006 CW4-008 CW4-010 CW4-012 CW4-014 CW4-017

Nominal Air volum e CFM 300 400 500 600 800 1000 1200 1400 1700

Coil

Copper tube 3/8”(9.52m m) OD seamless c opper tube

Fins H i e ff ic ie nc y w avy c orrugated a lum in iu m b lu e f in s

Fins per Inch FPI 12 12 12 12 12 12 12 12 12

Coil length mm 1480 1480 1790 1790 1790 2200 2200 2200 2520

Coil hight mm 200 200 225 225 225 250 250 250 250

Fan Fan type C en t r if u g a l b a c k w ar d cu r v e , A B S w h ee l, d ir e c t d r iv en

Qty pcs 1 1 1 1 1 1 1 1 1

AC Motor

Voltage 220- 240V / 1P h/ 50- 60H Z ,110- 127V / 1P h/ 50H ZMotors peed 3 s p e e d

Qty pcs 1 1 1 1 1 1 1 1 1Max power

input W 46 60 85 106 147 217 286 308 330

EC Motor

220- 240V / 1P h/ 50- 60H Z ,110- 127V / 1P h/ 50H ZQty pcs 1 1 1 1 1 1 1 1 1

Max power input W 30 40 50 60 80 88 200 228 258

Noise level at 1.0m distance

H dB(A) 38 43 46 45 50 51 52 55 58

M dB(A) 36 41 44 42 47 49 50 49 52

L dB(A) 34 38 39 39 44 47 48 47 50

Water p ip e

Cooling coil 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P

Heating coil (4 pipes unit) 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P 3/ 4”F T P

Drain pipe 3/ 4”M T P3/ 4”M T P

3/ 4”M T P

3/ 4”M T P

3/ 4”M T P 3/ 4”M T P 3/ 4”M T P 3/ 4”M T P 3/ 4”M T P

Package Dimension

L mm 720 720 850 850 850 1000 1000 1000 1200

W mm 720 720 850 850 850 1000 1000 1000 1200

H mm 370 370 370 370 370 370 370 370 370

Net Weight kg 25 25 29 29 29 37 37 37 59

Chilled Water 4-Way Ceiling CassetteTWP Series

Page 3: Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low

3www.innovair.com

2rows, 2pipes

The following rating conditions are used:Cooling:Entering air temperature: +27℃DB; +19.5℃WBWater inlet/outlet: +7/12℃

Heating:Entering air temperature: +20℃DBWater inlet/outlet: +70℃/60℃

Model

Air flo

H

CFM

320 366 509 667 819 1011 1165 1401 1701

M 284 304 424 571 619 921 995 1089 1236

L 181 188 365 437 440 792 836 942 995

Total Cooling Capacity

H

KW

3.66 3.91 5.42 6.75 7.96 10.15 11.37 13.17 16.11

M 3.32 3.36 4.67 5.95 6.35 9.41 10.02 10.77 12.47

L 2.27 2.26 4.13 4.79 4.81 8.33 8.70 9.59 10.46

Sensible Cooling Capacity

H

KW

2.44 2.66 3.69 4.63 5.50 6.96 7.83 9.11 11.08

M 2.21 2.28 3.16 4.07 4.35 6.43 6.86 7.40 8.50

L 1.49 1.51 2.79 3.25 3.26 5.67 5.93 6.56 7.09

HeatingCapacity

H 4.30 4.73 6.54 8.07 9.46 12.00 13.38 15.36 18.51

M KW 3.92 4.07 5.64 7.15 7.61 11.18 11.87 12.70 14.57

L 2.63 2.77 5.01 5.79 5.82 9.95 10.38 11.38 12.32

Water Flow Rate

H

L/S

0.17 0.19 0.26 0.32 0.38 0.48 0.54 63.00 0.77

M 0.16 0.16 0.22 0.28 0.30 0.45 0.48 0.51 0.60

L 0.11 0.11 0.20 0.23 0.23 0.40 0.42 0.46 0.50

WaterPressure Drop

H

Kpa

33.89 14.03 15.16 20.58 25.94 29.17 34.22 42.02 63.85

M 29.57 11.35 12.29 17.27 18.91 26.23 28.62 31.69 44.59

L 17.33 6.50 10.34 12.71 12.82 22.10 23.50 26.92 34.84

Chilled Water4-Way Ceiling Cassette

TWP Series

CW4-004 CW4-005 CW4-006 CW4-008 CW4-010 CW4-012 CW4-014 CW4-017 CW4-007

Page 4: Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low

4www.innovair.com

2+1rows, 4pipes

Performance Date2. ARI-440 Standard ratingThe following rating conditions are used:Cooling:Entering air temperature: +80℉DB; +67℉WBWater inlet/outlet: +45/55℉

Heating:Entering air temperature: +68℉DBWater inlet temperature: +140℉Water flow rate as for the cooling conditions.

Model

Air floH

CFM

320 366 5 0 9 6 6 7 8 1 9 1 0 1 1 1 1 6 5 1 4 0 1 1 7 0 1

M 2 8 4 3 0 4 4 2 4 5 7 1 6 1 9 9 2 1 9 9 5 1 0 8 9 1 2 3 6

L 1 8 1 1 8 8 3 6 5 4 3 7 4 4 0 7 9 2 8 3 6 9 4 2 9 9 5

TotalCoolingCapacity

H

K W

2 .9 2 3 .2 5 4 .5 3 5 .5 9 6 .5 5 8 .4 2 9 .4 0 1 0 .8 4 1 3 .3 2

M 2 .6 6 2 .8 1 3 .9 2 4 .9 5 5 .2 7 7 .8 3 8 .3 2 8 .9 2 1 0 .3 9

L 1 .8 2 1 .8 8 3 .4 8 4 .0 1 4 .0 3 6 .9 5 7 .2 6 7 .9 7 8 .7 6

SensibleCoolingCapacity

H

K W

1 .9 0 2 .1 3 2 .9 7 3 .7 0 4 .3 8 5 .5 3 6 .2 0 7 .1 9 8 .7 6

M 1 .7 3 1 .8 3 2 .5 5 3 .2 6 3 .4 8 5 .1 2 5 .4 5 5 .8 7 6 .7 6

L 1 .2 6 1 .3 0 2 .2 5 2 .6 2 2 .6 3 4 .5 3 4 .7 3 5 .2 1 5 .6 7

HeatingCapacity

H 3 . 5 2 3 . 8 5 5 . 4 1 6 . 4 5 7 . 3 6 9 . 3 1 1 0 . 1 9 1 1 . 4 4 1 3 . 8 0

M K W 3 .2 6 3 .4 1 4 .7 9 5 .8 3 6 .1 4 8 .7 6 9 .2 1 9 .7 6 1 1 .2 8

L 2 .3 9 2 .4 6 4 .3 3 4 .8 9 4 .9 1 7 .9 5 8 .2 3 8 .8 9 9 .8 1

CoolingWater FlowRate

H

L/S

0 .1 4 0 .1 5 0 .2 2 0 .2 7 0 .3 1 0 .4 0 0 .4 5 0 .5 2 0 .6 4

M 0 .1 3 0 .1 3 0 .1 9 0 .2 4 0 .2 5 0 .3 7 0 .4 0 0 .4 3 0 .5 0

L 0 .0 9 0 .0 9 0 .1 7 0 .1 9 0 .1 9 0 .3 3 0 .3 5 0 .3 8 0 .4 2

CoolingWaterPressure Drop

H

Kpa

1 5 . 4 3 1 7 . 9 3 1 5 . 6 5 2 1 . 0 4 2 6 . 2 9 4 5 . 9 4 5 3 . 6 5 6 5 . 4 4 1 0 0 . 1 0

M 1 3 . 5 4 1 4 . 6 2 1 2 . 7 8 1 7 . 7 5 1 9 . 3 9 4 1 . 4 7 4 5 . 1 4 4 9 . 8 2 7 0 . 6 6

L 8 . 1 4 8 . 5 3 1 0 . 8 2 1 3 . 2 1 1 3 . 3 2 3 5 . 1 2 3 7 . 2 7 4 2 . 4 9 5 5 . 5 9

HeatingWater FlowRate

H

L/S

0 .0 8 0 .0 9 0 .1 3 0 .1 5 0 .1 8 0 .2 2 0 .2 4 0 .2 7 0 .3 3

M 0 .0 8 0 .0 8 0 .1 1 0 .1 4 0 .1 5 0 .2 1 0 .2 2 0 .2 3 0 .2 7

L 0 .0 6 0 .0 6 0 .1 0 0 .1 2 0 .1 2 0 .1 9 0 .2 0 0 .2 1 0 .2 3

HeatingWaterPressure Drop

H

Kpa

9 . 2 4 1 0 . 4 4 1 1 . 5 5 1 4 . 6 9 1 7 . 5 9 1 9 . 8 7 2 2 . 4 9 2 6 . 3 4 3 9 . 0 2

M 8 . 3 0 8 . 8 3 9 . 7 8 1 2 . 8 0 1 3 . 7 4 1 8 . 3 0 1 9 . 5 9 2 1 . 2 0 2 9 . 6 0

L 5 . 4 3 5 . 6 5 8 . 5 2 1 0 . 0 5 1 0 . 1 1 1 6 . 0 2 1 6 . 8 1 1 8 . 6 7 2 4 . 4 5

Chilled Water4-Way Ceiling Cassette

TWP Series

CW4-004 CW4-005 CW4-006 CW4-008 CW4-010 CW4-012 CW4-014 CW4-017 CW4-007

Page 5: Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low

5www.innovair.com

2rows, 2pipes

The following rating conditions are used:Cooling:Entering air temperature: +80℉DB; +67℉WBWater inlet/outlet: +45/55℉

Heating:Entering air temperature: +68℉DBWater inlet/outlet: +180℉/+140℉

Model

Air flo

H

CFM

320 366 509 667 819 1011 1165 1401 1701

M 284 304 424 571 619 921 995 1089 1236

L 181 188 365 437 440 792 836 942 995

Total Cooling Capacity

H

Btu/h

11809 12492 17372 21536 25359 32424 36280 41946 51468

M 10717 10751 14949 19010 20273 30103 32014 34403 39966

L 7338 7270 13242 15324 15427 26690 27850 30649 33584

Sensible Cooling Capacity

H

Btu/h

7952 8635 12014 15017 17816 22594 25393 29522 35973

M 7201 7406 10273 13208 14130 20888 22287 23993 27645

L 4881 4915 9044 10546 10614 18430 19283 21297 23072

Heating Capacity

H 19318 21126 29249 36007 42151 53652 59728 68465 82595

M Btu/h 17611 18260 25290 31980 34096 49932 53072 56826 65154

L 12014 12253 22423 25836 26109 44471 46314 50854 55188

Water Flow Rate

H

Gpm

2.38 2.54 3.49 4.28 5.07 6.50 7.29 8.40 10.30

M 2.22 2.22 3.01 3.80 4.12 6.02 6.50 6.97 8.08

L 1.43 1.43 2.69 3.01 3.17 5.39 5.55 6.18 6.82

Water Pressure Drop

H

ftH2O

9.17 3.75 4.05 5.48 6.89 7.78 9.14 11.16 17.03

M 8.01 3.03 3.29 4.61 5.04 7.01 7.64 8.45 11.94

L 4.48 1.69 2.78 3.41 3.43 5.91 6.29 7.19 9.35

Chilled Water4-Way Ceiling Cassette

TWP Series

CW4-004 CW4-005 CW4-006 CW4-008 CW4-010 CW4-012 CW4-014 CW4-017 CW4-007

Page 6: Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low

6www.innovair.com

2+1rows, 4pipes

Mode l

Air flo

H

CFM

320 366 509 667 819 1 0 1 1 1 1 6 5 1 4 0 1 1 7 0 1

M 284 304 424 571 619 921 995 1 0 8 9 1 2 3 6

L 181 188 365 437 440 792 836 942 995

Total Cooling Capacity

H

Btu/h

9 2 4 9 1 0 2 7 3 1 4 3 3 5 1 7 6 1 1 2 0 6 1 5 2 6 6 5 6 2 9 7 2 7 3 4 1 9 8 4 2 1 8 5

M 8 4 3 0 8 9 0 8 1 2 4 2 3 1 5 6 3 2 1 6 6 2 1 2 4 8 1 3 2 6 3 4 8 2 8 2 2 6 3 3 0 0 4

L 5 8 0 2 6 0 0 7 1 1 0 5 8 1 2 6 9 6 1 2 7 6 5 2 2 0 8 2 2 3 0 3 8 2 5 2 5 6 2 7 8 8 4

Sensible Cooling Capacity

H

Btu/h

6 1 4 3 6 8 6 0 9 5 9 1 1 1 9 4 6 1 4 0 9 6 1 7 8 5 0 2 0 0 3 4 2 3 2 0 8 2 8 3 2 8

M 5 5 9 7 5 9 0 4 8 2 5 9 1 0 5 4 6 1 1 2 2 9 1 6 5 5 3 1 7 6 4 5 1 8 9 7 6 2 1 9 1 1

L 4 0 6 1 4 2 3 2 7 3 0 4 8 4 6 4 8 4 9 8 1 4 6 4 2 1 5 3 2 4 1 6 8 6 0 1 8 3 6 2

Heating Capacity

H

Btu/h

1 1 9 4 6 1 3 0 0 4 1 8 2 6 0 2 1 5 7 0 2 4 4 7 1 3 1 6 7 3 3 4 5 4 0 3 8 6 3 5 4 7 1 6 8

M 1 1 0 9 2 1 1 5 7 0 1 6 2 4 6 1 9 5 9 1 2 0 6 1 5 2 9 8 9 8 3 1 3 6 5 3 3 1 4 0 3 8 8 4 0

L 8 2 5 9 8 4 6 4 1 4 7 4 4 1 6 5 5 3 1 6 6 2 1 2 7 2 3 6 2 8 1 5 7 3 0 3 0 7 3 3 9 2 5

CoolingWater FlowRate

H

Gpm

1 .9 0 2 .0 6 2 .8 5 3 .4 9 4 .1 2 5 .3 9 6 .0 2 6 .8 2 8 .5 6

M 1 .7 4 1 .7 4 2 .5 4 3 .1 7 3 .3 3 5 .0 7 5 .2 3 5 .7 1 6 .6 6

L 1 .1 1 1 .2 7 2 .2 2 2 .5 4 2 .5 4 4 .4 4 4 .6 0 5 .0 7 5 .5 5

CoolingWaterPressure Drop

H

ft 2O

4 .0 7 4 .7 2 4 .1 1 5 .5 1 6 .8 6 1 2 .1 0 1 4 .1 0 1 7 .1 7 2 6 .3 7

M 3 .5 8 3 .8 5 3 .3 7 4 .6 6 5 .0 8 1 0 .9 3 1 1 .8 9 1 3 .1 1 1 8 .7 0

L 2 .1 7 2 .2 7 2 .8 6 3 .4 8 3 .5 1 9 .2 9 9 .8 5 1 1 .2 1 1 4 .7 5

HeatingWater FlowRate

H

Gpm

0 .6 3 0 .6 3 0 .9 5 1 .1 1 1 .2 7 1 .5 9 1 .7 4 1 .9 0 2 .3 8

M 0 .4 8 0 .6 3 0 .7 9 0 .9 5 0 .9 5 1 .4 3 1 .5 9 1 .5 9 1 .9 0

L 0 .4 8 0 .4 8 0 .7 9 0 .7 9 0 .7 9 1 .4 3 1 .4 3 1 .5 9 1 .7 4

HeatingWaterPressure Drop

H

ft 2O

1 .0 3 1 .1 6 1 .2 8 1 .6 1 1 .9 1 2 .2 2 2 .5 1 2 .9 2 4 .4 0

M 0 .9 3 0 .9 9 1 .0 9 1 .4 1 1 .5 1 2 .0 5 2 .1 9 2 .3 7 3 .3 7

L 0 .6 2 0 .6 5 0 .9 5 1 .1 2 1 .1 2 1 .8 1 1 .8 9 2 .0 9 2 .8 0

Chilled Water4-Way Ceiling Cassette

TWP Series

CW4-004 CW4-005 CW4-006 CW4-008 CW4-010 CW4-012 CW4-014 CW4-017 CW4-007

Page 7: Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low

7www.innovair.com

2rows, 2pipes

3. District Cooling Standard ratingThe following rating conditions are used:Cooling:Entering air temperature: +24.4℃DB; +17.2℃WBWater inlet/outlet: +5.5/14.4℃

Model A B C D

CW4-003 680 580 614 424CW4-004 680 580 614 424CW4-005 830 705 737 338CW4-006 830 705 737 338CW4-008 830 705 737 338CW4-010 980 832 864 416CW4-012 980 832 864 416CW4-014 980 832 864 416CW4-017 1140 960 992 488

Model

Air f low

H

CFM

320 366 509 667 819 1011 1165 1401 1701M 284 304 424 571 619 921 995 1089 1236L 181 188 365 437 440 792 836 942 995

Total Cooling Capacity

H

KW

2.44 2.42 3.37 4.10 4.76 6.24 6.92 7.91 9.90M 1.56 1.47 2.94 3.66 3.88 5.82 6.16 6.59 7.83L 1.42 1.62 2.63 3.01 3.02 5.21 5.42 5.92 6.66

Sensible Cooling Capacity

H

KW

2.00 2.11 2.94 3.66 4.32 5.52 6.19 7.18 8.80M 1.81 1.82 2.53 3.23 3.45 5.12 5.45 5.86 6.80L 1.24 1.22 2.24 2.59 2.61 4.52 4.73 5.21 5.70

Water Flow Rate

H

L/S

0.07 0.06 0.09 0.11 0.13 0.17 0.19 0.21 0.27M 0.06 0.06 0.08 0.10 0.10 0.16 0.17 0.18 0.21L 0.04 0.04 0.07 0.08 0.08 0.14 0.15 0.16 0.18

Water Pressure Drop

H

Kpa

8.57 3.19 3.46 4.56 5.63 6.56 7.59 9.15 14.38M 7.54 2.63 2.86 3.89 4.23 5.96 6.45 7.08 10.34L 4.58 1.59 2.44 2.95 2.97 5.10 5.39 6.10 8.25

Dimensional Data

Chilled Water4-Way Ceiling Cassette

TWP Series

CW4-004 CW4-005 CW4-006 CW4-008 CW4-010 CW4-012 CW4-014 CW4-017 CW4-007

Page 8: Chilled Water 4-Way Ceiling Cassette - Innovair · P4CM 4-way ceiling cassette fan coil units use square panel design, 4-way air outlet, distribute air equally, run steady with low

8www.innovair.com

C

D

Chilled Water4-Way Ceiling Cassette

TWP Series