CATHODE RAY OSCILLOSCOPE

Page 2: Chepter 5 eim

TOPICS COVERED :Introduction to CROBlock diagram of CRODetailed description of CRTMulti –Input OscilloscopeLissajous PatternsTypes of Oscilloscope and it’s application

Page 3: Chepter 5 eim

HOW A CRO LOOKS LIKE

Page 4: Chepter 5 eim

INTRODUCTION TO CROVersatile electronic instrument giving

visual display of signals Used for measurement of frequency ,

amplitude, phase etc.Also used in determining the nature and

characteristics of various components. Has a high bandwidth range thus making

it a sensitive and accurate device.Easier to use as the internal routine act as

a guide to the user.

Page 5: Chepter 5 eim

BASIC DIAGRAM

Page 6: Chepter 5 eim

ANOTHER SCOOP….

Page 7: Chepter 5 eim

WORKING OF A CRO

Page 8: Chepter 5 eim

CATHODE RAY TUBE

The main parts of Cathode Ray Tube are:

•Electron Gun Assembly•Focusing Anodes•Deflection Plates Assembly•Screen for CRT

Page 9: Chepter 5 eim
Page 10: Chepter 5 eim

Electr

on Gun

Page 11: Chepter 5 eim

Anodes

Page 12: Chepter 5 eim

Deflection Plates

Page 13: Chepter 5 eim

Fluorescent Screen

Page 14: Chepter 5 eim

Multi-Input OscilloscopeOscilloscope can have multiple input and display facilities.

Page 15: Chepter 5 eim

The most common one is of - TWO INPUTS.

Although FOUR and EIGHT inputs are available for special applications

Page 16: Chepter 5 eim

There are primary two types of multi-input oscilloscope :-

Single Beam Oscilloscope

Dual Beam Oscilloscope Both of them can be converted into a further Number of traces.

Page 17: Chepter 5 eim

Dual Trace Oscilloscopes

Page 18: Chepter 5 eim

In this oscilloscope two separate vertical input channels are used.

There are two common operating modes for the Electronic Switch, called Alternate and Chop which can be selected from the instrument’s front panel.

Dual Trace Oscilloscopes

Page 19: Chepter 5 eim

BLOCK DIAGRAM

Page 20: Chepter 5 eim

Dual Beam OscilloscopeThe Dual Beam Oscilloscope has two separate electron beams , and therefore two completely separate vertical channels.

Page 21: Chepter 5 eim

There are two methods used for generating the two electron beams within the CRT.

The first method is :-

Double gun tube

Split Beam

Page 22: Chepter 5 eim

Multiple input CRO works in following two modes

alternate modechopped mode

Page 23: Chepter 5 eim

Alternate mode

In alternate mode the an electronic switch alternates between sig A & B.

Page 24: Chepter 5 eim

Waveform in alternate mode

Page 25: Chepter 5 eim

Chopped modeIn the chopped mode the switch free runs at very high frequency.

Page 26: Chepter 5 eim

Waveform of Chopped Mode

Page 27: Chepter 5 eim

Lissajous Pattern

When two sinusoidal voltage signals of equal frequency having some phase difference are applied to the deflection plates of CRO, a straight line or an ellipse appears on the screen these figures are called Lissajous figures or Lissajous curves or pattern.

Page 28: Chepter 5 eim

Some examples of lissajous figures……..

Page 29: Chepter 5 eim

With the help of lissajous figures we can measure…….

FrequencyPhase

Page 30: Chepter 5 eim

Frequency Measurement

Fx/Fy = Hp/Vp

Fx = Unknown frequencyFy = Known frequencyHp = Points on horizontal tangenciesVp = Points on vertical tangencies

Page 31: Chepter 5 eim

Phase Measurement

sin Ф = c/b

Page 32: Chepter 5 eim

Digital Storage Oscilloscope

Page 33: Chepter 5 eim

BLOC

BLOCK DIAGRAM OF DSO

Page 34: Chepter 5 eim

Advantage Of DSO

Stores waveform for infinite time

Digitize waveform can be processed in any way

Writing speed is more

Processing of signal is easy

Page 35: Chepter 5 eim

Analog Storage Oscilloscope

Page 36: Chepter 5 eim

Trace storage is an extra feature

They used direct-view storage CRTs

The storage is accomplished using the principle of secondary emission

Briefings

Page 37: Chepter 5 eim

Data can be stored to infinite time

Image quality is good

Writing speed is high

Processing of signal is easy

Data can be stored for finite time

Image quality is not poor

Writing speed is poor

Processing of signal is difficult

Difference between ASO & DSODSO

ASO

Page 38: Chepter 5 eim

THANK u