Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio...

18
Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT

description

Motivation DNBI has been installed on TJ-II CXRS local measurements of Ion Temperatures Poloidal & Toroidal Velocities Electric fields Impurity densities using experimental data + simulation code A lot of work to do…

Transcript of Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio...

Page 1: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Charge Exchange Spectroscopic Diagnostic for the TJ-II

José Miguel Carmona Torres

Laboratorio Nacional de FusionEURATOM-CIEMAT

Page 2: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Contents

• Motivation• Stellarator TJ-II• Diagnostic Neutral Beam Injector• Multichannel Diagnostic• Beam Characterization• Interaction and corrections• Estimation of Counts

Page 3: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Motivation

•DNBI has been installed on TJ-II

•CXRS local measurements of

IonTemperatures

Poloidal & ToroidalVelocities

Electric fieldsImpurity densities using experimental

data + simulation code

A lot of work to do…

Page 4: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Contents

• Motivation• Diagnostic Neutral Beam Injector• Stellarator TJ-II• Multichannel Diagnostic• Beam Characterization• Interaction and corrections• Estimation of Counts

Page 5: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Stellarator TJ-II

•An Heliac Flexible device•Minor and mayor radii from 0.22 m to 1.5 m•B created by external coils (Bmax=1 T)•ECRH y NBI heating•Plasma cross section is bean-shaped

TJ-II Mag. flux surfaces for 2 diferent magnetic configurations. Magnetic Islands appers on diferent configurations as 58_83_61 .

Fully tridimensional plasma structure with easy access to portholes

Page 6: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Contents

• Motivation• Stellarator TJ-II• Diagnostic Neutral Beam Injector• Multichannel Diagnostic• Beam Characterization• Interaction and corrections• Estimation of Counts

Page 7: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Diagnostic Neutral Beam Injector

DNBISECTOR

A7

TOPPORTHOLE

NBI_1 NBI_2

Scheme of DNBI

Picture of DNBI installed in the TJ-II

Dnbi Parameters-Focal length 170 cm-Pulse length 5 ms -Beam Energy ~30 KeV-1/e divergence <0.7 º-1/e radius at focus ~21 mm-Extracted ion current 4 A/cm2

-Beam Components (H,H2,H3) ~90%, ~8%, 2%

DNBI sector A7, mounted on a support structureRev. Sci. Instrum. 75, 3499 (2004)

Page 8: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Contents

• Motivation• Stellarator TJ-II• Diagnostic Neutral Beam Injector• Multichannel Diagnostic• Beam Characterization• Interaction and corrections• Estimation of Counts

Page 9: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Multichannel Diagnostic

Canon 85 mmF/1.2 l USM

12 fiber arrayFiberguide Industries

diameter 600m

Holospec Spectrographf/1.8 high resolution and high dispertion grating

CCD Pixis Princeton Instrum. back-illuminated 1024 x 1024 Pixels (13 m)

J.M. Carmona et al. HTTP Conference 2006, Virginia, USA

*

* Ilustration from Alcator

Page 10: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Multichannel Diagnostic

J.M. Carmona et al. Rev. Sci. Instrum. 77, (2006) In press

Page 11: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Contents

• Motivation• Stellarator TJ-II• Diagnostic Neutral Beam Injector• Multichannel Diagnostic• Beam Characterization• Interaction and corrections• Estimation of Counts

Page 12: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Beam CharacterizationHypothesis:• Homogeneos source• Elemental beams emitted from source dS• of neutrals Termal Distrib.Multiple sum of coaxial Gaussians

V

2

2

exp)(),(zrzgrzzj f

b

b

t

b

TE

vv

2

2

• Convolution between Gaussians and Q(rz)=Q(r1-z/zf)

20,exp0,),( rzj

Izjrzj

j(z,0) I

a2

z*2

z2 1 exp a2

z*2

Neutral beam profile in vacuum:

2

*

2

2

*

2 0,expexp1),( 2

2

rzjIz

azz

aIrzj

P. Bosshard Thesis, TCV

Page 13: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Contents

• Motivation• Stellarator TJ-II• Diagnostic Neutral Beam Injector• Multichannel Diagnostic• Beam Characterization• Interaction and corrections• Estimation of Counts

Page 14: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Interaction and corrections

totimpimp

totpp

b

eee nn

vv

n

•Beam attenuation by means of collisions

z

z

dzzIzIdzI

dI

0

exp)(/)( 0 attenuation coefficient

Proton and Imp.densities?

eeff

impeeff

p nZZ

Znn

ZZZ

n)1(

11

Page 15: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Interaction and corrections•Some corrections on are needed ve

ADAS databaseVneutrals<<Velectrons

f (Te)

•Vneutrals=30 KeV Vneutrals106 m/s Velectrons107 m/s

e

be

b

e

e

eber T

EvMT

mEvvv 132

b

e

Mmwith

32

effreff TvE 2/32/1 2

2/1 ebeeff TETT

J.M. Carmona et al. EPS Conference. Tarragona 2005

Page 16: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Contents

• Motivation• Stellarator TJ-II• Diagnostic Neutral Beam Injector• Multichannel Diagnostic• Beam Characterization• Interaction and corrections• Estimation of Counts

Page 17: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Estimation of Counts

•Photons? Charge-Exchange

h (CVI 87)

•Number of photons

PCX

14

Aij(8 7)

Aijv i N idl

i

N imp t sist

Branching RatioRate coefficients for 30, 15, 10 KeV Optical window, lens, fibers, coupling,

spectrograph and CCD total efficiency

Page 18: Charge Exchange Spectroscopic Diagnostic for the TJ-II José Miguel Carmona Torres Laboratorio Nacional de Fusion EURATOM-CIEMAT.

Some results

An ‘artistic view’ of the simulation code, showing attenuated (red) vs non-attenuated beam (green)

First measurements are expected to be obtained in the next campaign