Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr....
Transcript of Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr....
![Page 1: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/1.jpg)
Dr. Subash ArunGuide
Dr. Srinivas Murki
Changes in Blood Pressure and Echocardiographic Parameters in
Neonates with Shock – An Observational Study
Hyderabad, INDIAwww.fernandezhospital.foundation
![Page 2: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/2.jpg)
Introduction
▪ Diagnosis and Management of shock is challenging
▪ Routine clinical parameters - very low diagnostic utility
▪ Bedside ECHO: Routine practice for managing shock in NICU
![Page 3: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/3.jpg)
Existing Evidence
▪ Only few studies evaluated the role of fECHO in neonatal Shock (e.g. Saini et al and Baske et al)
▪ These studies evaluated Hemodynamics at onset of shock
▪ Comparison with control is missing
▪ Enrolled newborns with only septic shock
![Page 4: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/4.jpg)
Study Objective
To evaluate the changes in
▪ Blood pressure (systole, diastole, mean arterial pressure i.e. MAP) and
▪ Echocardiographic markers of
Preload
Diastolic function
Systolic function
Onset of Shock Complete Resolution of shock
![Page 5: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/5.jpg)
Patients
▪ All neonates with shock included in study
Exclusions
▪ Received fluid boluses or inotropes prior to enrollment
▪ Neonates having major congenital anomalies
▪ Neonates undergoing therapeutic hypothermia
![Page 6: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/6.jpg)
Methods
▪ Prospective observational study
▪ October 2017 to May 2019
▪ Fernandez Hospital, Hyderabad – Tertiary care hospital
▪ Consent : At admission to NICU for possible enrollment
▪ All newborns were screened for features of shock hourly
▪ Newborns diagnosed with shock were monitored for
Clinical parameters
ECHO parameters
![Page 7: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/7.jpg)
Shock defined as
Any 2 of following 6 parameters*
▪ HR>180/min
▪ CRT>3 sec
▪ Core to periphery difference >30C
▪ Base Excess >-5 in blood gas/ Lactate > 2 times normal
▪ Hypotension:
▪ Oliguria* International paediatric sepsis consensus conference, Goldstein B et al
![Page 8: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/8.jpg)
Echocardiographic Evaluation
Echo imaging was done only by PI who was trained by pediatric cardiologist.
▪ IVC collapsibility index
▪ Left ventricular end diastolic volume (LVEDV)
▪ Mitral E/A ratio
▪ Isovolumetric relaxation time (IVRT)
▪ Left ventricular output
▪ Ejection Fraction
▪ Right ventricular output
Preload
Diastolic function
Systolic function
![Page 9: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/9.jpg)
Shock Resolution
All of the following should be present-
▪ Heart rate 120 to 160 per min
▪ Capillary refill time < 3 seconds
▪ Blood pressure : >30 mm of Hg/ >5th GA
> 5th Centile for GA or systolic BP >2SD
▪ Urine output : >1 ml/kg/hour
▪ Normal peripheries Core to peripheral temperature < 3°C
▪ Not on inotropes
▪ No acidosis and normal lactate
![Page 10: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/10.jpg)
Primary Outcome
▪ Median Change in
– Clinical Parameters
– Echo Parameters
At Onset of shock and at complete resolution of shock
![Page 11: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/11.jpg)
Secondary Outcome
▪ Comparison of Clinical diagnosis versus echo diagnosis of Shock
![Page 12: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/12.jpg)
Protocol
▪ For logistic and ethical reasons, only feasible parameters were recorded before giving bolus and rest either before or during saline bolus infusion / starting of inotropes
▪ Echo images - reviewed by pediatric cardiologist blinded to clinical findings
▪ Shock Management - as per standard unit protocol
▪ Clinical and echo parameters -repeated after resolution
![Page 13: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/13.jpg)
Sample Size and Statistics
▪ No a-priori sample estimation done
▪ Median changes in clinical and Echo parameters at onset and after resolution of shock done by Wilcoxon signed rank test
▪ All the analysis was done using statistical software packages SPSS version 23 (IBM, New York)
![Page 14: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/14.jpg)
Results
![Page 15: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/15.jpg)
Infants admitted to NICU (N=1416)
Infants Diagnosed with shock
(N= 59)
Infants enrolled for study (N= 37)
Infants for paired analysis (N=31)
Excluded cases before
enrollement(N=22)
Excluded cases after enrollment
from paired analysis (N=6)
Study flow chart
![Page 16: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/16.jpg)
Characteristics/ Variables Baseline data
Gestational Age (weeks) 30±3
Maternal age (years) 28.5±3.8
Birth weight (grams) 1213±448
Male gender (%) 20 (54)
Small for date (%) 9 (24.3)
Age at shock (days) 3.5 (2.5,6)
Weight loss at shock (%) 7.9±4
Blood pH at shock 7.20 (± 0.07)
Base Excess at shock 9.87 (± 2.5)
Blood culture +ve sepsis (%) 21 (56.8)
Probable sepsis (%) 6 (16.2)
HsPDA (%) 6 (16.2)
Baseline Characteristics
![Page 17: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/17.jpg)
Indicator of shock Number(percent)N=37
HR>180/min 35(94.5)
CRT>3 sec 26(70)
Core to periphery difference >30C 30(81)
Base Excess >-5 in blood gas 33(89.18)
Elevated Lactate > 2 times 35(94.5)
Hypotension 0(00)
Oliguria 0(00)
Diagnosis of Shock
![Page 18: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/18.jpg)
Parameters Medians (IQR) P value
At shock After resolution
HR(per min) 186(183,190) 140(138,146) <0.001
SBP(mm Hg) 61(56,68) 65(62,68) 0.75
DBP(mm Hg) 32(30,38) 39(36,42) 0.001
MAP(mm Hg) 46(40,50) 48(46,51) 0.007
Changes in Clinical Parameter at Onset and Resolution of Shock
![Page 19: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/19.jpg)
Parameters Medians (IQR) P value
At shock After resolution
IVC Collapsibility Index % 42(23,48) 25(18,33) <0.001
LVEDV(ml) 5.8(2.9,9.6) 8(5,13) 0.003
Changes in Preload Parameters at Onset and Resolution of Shock
![Page 20: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/20.jpg)
Parameters Medians (IQR) P value
At shock After resolution
IVRT(milliseconds) 42(39,47) 39(34,44) 0.002
E/A ratio 0.77(0.7,0.8) 0.75(0.66,0.8) 0.25
Changes in Diastolic cardiac function at onset and resolution of Shock
![Page 21: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/21.jpg)
Parameters Medians (IQR) P value
At shock After resolution
LVO(ml/kg/min) 165(115,213) 179(141,241) 0.15
RVO(ml/kg/min) 246(181,298) 213(171,314) 1.0
Left Ventricular stroke volume(ml)
1(0.7,1.3) 1.47(1.3,1.8) <0.001
Right Ventricular stroke volume(ml)
1.4(1.2,1.8) 2(1.4,2.6) <0.001
EF (%) 69(62,74) 75(71,79) <0.001
Changes in Systolic Cardiac Function at onset and Resolution of Shock
![Page 22: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/22.jpg)
Parameters Medians (IQR) P value
At shock After resolution
SVR Index(mmHg/ml/kg/min)
0.27(0.22,0.38) 0.26(0.17,0.33) 0.4
Systemic Vascular resistance (SVR) Index : MAP/LVO
Changes in SVR Index at Onset and Resolution of Shock
![Page 23: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/23.jpg)
Time of resolution of shock Number (%)
12 to 24 hours 4(13%)
24 to 48 hours 17(55%)
48 to 72 hours 9(29%)
>72 hours 1(3.2%)
Time for Resolution of Shock
![Page 24: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/24.jpg)
Secondary Outcomes ▪ Clinical Diagnosis of Shock
Hypovolemic shock- 5 (14%)
Cardiogenic shock - 3 (8%)
Clear classification not possible - 29 (78%)
▪ Echo Diagnosis of Shock
Hypovolemic shock- 3 (8%)
Cardiogenic shock – 8 (22%)
Clear classification not possible– 26 (70%)
![Page 25: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/25.jpg)
Study Strengths▪ First study to Echo Parameters at onset and after
shock resolution
▪ Ideal study in which each infant acted as its own control
▪ Identified the median differences in Clinical and Echo parameters in newborns with shock
▪ Includes newborns with all types of shock (not only sepsis)
▪ Cardiologist blinded to the clinical details
![Page 26: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/26.jpg)
Median Changes (Onset vs. Resolution)
▪ Preload PVI 12%
IVC CI 13%
LVEDV 2.3ml
▪ Diastolic Cardiac Function IVRT 4msMitral E/A 0.03
▪ Systolic Cardiac Function LVSV 0.3ml
RVSV 0.4ml
EF 7%
▪ Marker of Distributive shock SVR Index 0.04
![Page 27: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/27.jpg)
Clinical Application of Study Findings
![Page 28: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/28.jpg)
Clinical Implications
▪ Identify infants at risk for shock at admission to
NICU
▪ Evaluate IVC collapsibility index, MAP and Echo
parameters at admission or as early as possible
▪ Revaluate the same parameters at onset of shock to
– Classify pathophysiology of shock
– Manage shock from pathophysiology
![Page 29: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/29.jpg)
Hypovolemic shock(median change)
Cardiogenic shock
Distributive shock(median change)
Diastolic dysfunction
(median change)
Systolic dysfunction
(median change)
1. IVC Collapsibility Index>13%
2. LVEDV < 2.3 ml
1. IVRT>4ms2. E/A
ratio>0.03
1. LSV<0.3ml2. RSV<0.4ml3. EF<7%
SVR Index < 0.04(mmHg/ml/kg/min)
![Page 30: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/30.jpg)
Study Limitations
▪ Exclusively inborn neonates
▪ Sample size small
![Page 31: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/31.jpg)
Conclusion
Our study highlights the need for baseline documentation of clinical and echo parameters and to observe their changes at onset of shock. Future validation is needed to manage infants with shock based on the changes observed in this study
![Page 32: Changes in Blood Pressure and Echocardiographic Parameters ... · Dr. Subash Arun Guide Dr. Srinivas Murki Changes in Blood Pressure and Echocardiographic Parameters in Neonates with](https://reader036.fdocuments.in/reader036/viewer/2022070720/5ee018c5ad6a402d666b5847/html5/thumbnails/32.jpg)