CHAMBER FOR TESTING WATERTIGHTNESS, AIR … · In an increasing number of refractory ... CONCRETE...

23
WINDOWS AND DOORS EN 12155:2000 Air permeability EN 1027:2000 Watertightness EN 12211:2000 Resistance to wind load CURTAIN WALLING EN 12155:2000 Watertightness EN 12153:2000 Air permeability EN 12179:2000 Resistance to wind load Width 4000 mm Height 4000 mm Depth 200 mm INTERNAL CHAMBER DIMENSIONS Free standing chamber Over head Crane Test piece fixation in sample chamber Positive or negative rapid changes for test pressure. ± 10 % of accuracy about measuring the quantity of water supplied ± 5 % of accuracy about positive or negative test pressures, steady or fluctuating applied across the specimen ± 5 % of accuracy about air flow into or out of the chamber Adjustable device for spraying water as 2 L/ m 2 ×min (m 2 ×min) CHAMBER FOR TESTING WATERTIGHTNESS, AIR PERMEABILITY AND RESISTANCE TO WIND LOAD OF FACADE WINDOWS, DOORS AND CURTAIN WALLS, TEST SPECIMEN 4 m X 4 m , FR-TEST- WIN. 400

Transcript of CHAMBER FOR TESTING WATERTIGHTNESS, AIR … · In an increasing number of refractory ... CONCRETE...

WINDOWS AND DOORS

EN 12155:2000 Air permeability

EN 1027:2000 Watertightness

EN 12211:2000 Resistance to wind load

CURTAIN WALLING

EN 12155:2000 Watertightness

EN 12153:2000 Air permeability

EN 12179:2000 Resistance to wind load

Width 4000 mm

Height 4000 mm

Depth 200 mm

INTERNAL CHAMBER DIMENSIONS

Free standing chamber

Over head Crane

Test piece fixation in sample chamber

Positive or negative rapid changes for test

pressure.

± 10 % of accuracy about measuring the

quantity of water supplied

± 5 % of accuracy about positive or negative

test pressures, steady or fluctuating applied

across the specimen ± 5 % of accuracy about air flow into or out

of the chamber

Adjustable device for spraying water as 2 L/ m2×min

(m2×min)

CHAMBER FOR TESTING WATERTIGHTNESS, AIR PERMEABILITY AND

RESISTANCE TO WIND LOAD OF FACADE WINDOWS, DOORS AND

CURTAIN WALLS, TEST SPECIMEN 4 m X 4 m ,

FR-TEST- WIN. 400

Measuring amount of water supplied within an accuracy of 10 %.

Measuring range of test pressure: 0 Pa to 4000 Pa

The display and measuring range of air leakage: 0 m3/h to 10 m3/h.

Corrosion protected materials

Closed circulated water system.

Amount of water supplied within an accuracy 10 %

Range of test pressure 0 Pa to 4000 Pa

Range of air leakage 0 m3/h to 100 m3/h.

Angle of Spray 110º -120º

Pressure working range 2-5 bars

Top row nozzle 2 L/min ± 0,2

Nozzle rate 1 L/min ± 0,1 (selectable)

SPRAYING SYSTEM

Applies a continuous regularly dispersed film of water

Circular cone nozzles

WINDOWS AND DOORS

EN 1026:2000 Air permeability

EN 1027:2000 Water-tightness

EN 12211:2000 Resistance to wind load

CURTAIN WALLING

EN 12153:2000 Water-tightness

EN 12155:2000 Air permeability

EN 12179:2000 Resistance to wind load

INTERNAL CHAMBER

DIMENSIONS

Width 3000 mm

Height 3000 mm

Depth 200 mm

± 10 % of accuracy about measuring the quanti-

ty of water supplied

± 5 % of accuracy about positive or negative

test pressures, steady or fluctuating applied

across the specimen ± 5 % of accuracy about air flow into or out of

the chamber

Free standing chamber

Overhead Crane

Test piece fixation in sample chamber

Positive or negative rapid changes for test

pressure.

SPRAYING SYSTEM

Applies a continuous regularly dispersed film of water

Circular cone nozzles

Angle of Spray 110º -120º

Pressure working range 2-5 bars

Top row nozzle 2 L/min ± 0,2

Nozzle rate 1 L/min ± 0,1 L per nozzle

(selectable)

GUARDED HOT BOX

DETERMINATION OF THERMAL TRANSMITTANCE

EN ISO 8990:1996 Thermal insulation

EN 12412-2:2003 Thermal performance of windows,

doors and shutters

EN 12412-4:2003 Thermal performance of windows,

doors and shutters (Part 4 Roller

shutter boxes )

EN ISO 12567-1:2010

+ AC: 2010 Thermal performance of windows

and doors, Part 1: Complete windows

and doors

EN ISO 12567-2:2005 Thermal performance of windows

and doors,Part 2: Roof windows and

other projecting windows.

Instrumentation and automated control

Metering box walls

Automatic data acquisition and documentation

Sample plate sıze 300x300 mm

U-factor range (0.1 - 4) W/(m2×K)

Temperature range (Cold) 18°C to +5 °C

Temperature range (Warm) +5 °C to +40 °C

Accuracy ± 5%

Power Supply 3 x (380-400) V, 50 Hz

GUARDED HOT PLATE APPARATUS

Thermal Cunductivity 5 Mw/(m-K)

Thermal Resistance 0,2 (m2×K)/W

5 (m2×K)/W.

Sample Plate Size 300x300 mm

Sample Size 10 mm - 200 mm

Temperature

Plate Size

10 °C and 40 °C

5 K to 15 K

Reproducibility < 0.5%.

Accuracy < 1%.

Power Supply 220 V—50 Hz

FR TEST HTPL F 300-XM

ISO 8302:1991 Thermal insulation

EN 1946-2:1999 Thermal performance of building

products and components .Part 2:

Measurements by guarded hot plate

method.

EN 12664:2001 Dry and moist products of medium

and low thermal resistance

EN 12667:2001 Products of high and medium ther-

mal resistance

EN 12939:2000 Thick products of high and medium

thermal resistance.

FR-AG 45

Horizontal Rotating

Table

Table Diameter 750 mm

Rotation 30 ± 1

Test Track

Inside Radius 120 mm

Outside Radius 320 mm

Width 200 ± 0.5

Hardness 200 HB 2.5/187.5

Specimen Holder U Frame

Thickness 40 mm 5 ± 1 mm

Test Force 295 +-1 N

Power Supply 380-400 V - 50 Hz,

1 or 3 phase.

Accessory:

Artificial corundum sand

EN 13892-3:2014

EN 13892-3:2014

EN 14157:2004 Natural stone

EN 1338:2003 Concrete paving blocks

EN 1339:2003 Concrete paving flags

EN 1340:2003 Concrete kerb units

EN 13892-3:2014 Screed materials

BÖHME ABRADER FOR DETERMINATION OF

WEAR RESISTANCE

DATA LOGGER FOR VIBRATING WIRE SENSORS

Channel Quantity 16

Measurement Accuracy ± 0.05%

Power Supply 220 V—50 Hz

QUALITY DOCUMENTS

ASTM D4435-84:1998 Clauses 1 to 10

ASTM D4436-84:1998 Clauses 1 to 11

EN 5080-1:1993 Clauses 7, 8 and 9

DIN 21521-2:1993 Clauses 6 and 7

EN 124:2011 Clause 8

EN 1537:2011 Clause 9

EN ISO 9969: 2009 Clause 8

SRPS U.M1.046:1984 Clauses 1 to 5

SRPS U.M1.047:1987 Clauses 1 to 6

PREFERENCES

Subsequent compression test-

ing 0.0006d

Rotating grinding head power 3.2 kW

Rotating grinding head power 1500 RPM

Radial displacement of the unit Right-left swing

Base table 100 mm cubes (three) 150 mm cubes (three)

Vertical clearance and travel of

the grinding head 200 mm side length

Cylinders 150 mm / 300 mm

Height

Power Supply 380-400 V, 50 Hz, 3

ph.

PREFERENCES

QUALITY

DOCUMENTS

EN 12390-2:2009

EN 12390-1:2012 Size and shape of the

samples

GRINDER FOR CONCRETE SAMPLES

Grinding head abrasion sectors impregnated with

diamond.

ACCESSORY:

Base table cylinders Ø 150 mm

Cubes side lengths 100 mm,

150 mm

200 mm

Clamping 100 mm cubes (three)

150 mm cubes (three)

TEST EQUIPMENT FOR COMPRESSION STRENGTH, FLEXURE

STRENGTH, ELASTIC MODULUS, AND SPLITTING TENSILE

STRENGTH OF CONCRETE

EN 12390-4:2000 Part 4: Compressive strength

EN 12390-3:2009 Part 3: Compressive strength

of test specimens

EN 772-1:2011 Part 1: Determination of

compressive strength

EN 12390-5:2009 Part 5: Flexural strength of

test specimens

EN 12390-6:2009 Part 5: Flexural strength of

test specimens

EN 12390-13:2013 Part 13: Determination of

secant modulus of elasticity in

compression

EN 1338:2003

+ AC:2006 Concrete paving blocks

EN 1339:2003

+ AC:2006 Concrete paving flags

EN 1340:2003

+ AC:2006 Concrete kerb units

Servo-hydraulic system

Hydraulic pump with oil-flow control

220-230 V / 50 Hz Power supply

The most advanced ultra-sonic test system for accurately identifying basic characteristics of

coarse grained materials such as concrete, wood, masonry, ceramic, graphite and more!

ÜRÜN MODELİ DE-ĞİŞCEK!!!

Applications

Locate Honey Combs and Voids in Concrete

Locate Cracks in Concrete, Ceramics, Masonry or Stone

Determine Fire Damage Extent in Concrete or Masonry

Crack Depth Determination

Determining Young's Modulus ( with optional Shear Wave Transducers )

Find Hidden Areas of Rotting Wood

Features & Benefits

System has a direct digital read-out of transit time, and read out of wave form on daylight display,

back lit LCD.

Rugged and splash resistant case is built for tough construction environments. Portable, and light

weight with both rechargeable battery and standard A-C power.

Includes a signal and trigger output for use with external oscilliscope or other data input device. Di-

gital calibration means no special bar required. Trigger levels and Signal amplification can be digitally

adjusted.

USB interface for computer control. Velocilinx™ software allows complete control of the system as

well as data upload to a PC and data analysis.

Direct reading of calculated P-wave velocity and S-wave velocity. The unit can also calculate modu-

lus of elasticity of material using optional S-Wave Transducers. Direct reading of Poisson's ratio.

Product Information

Concrete

The (ÜRÜN İSMİ YAZILACAK!!!!!!!) is widely used and accepted for quality control and inspection of

concrete. It can measure and correlate concrete strength to standard strength measurement, permitting non-

destructive testing of complete structures. It will identify honeycombs, voids, frozen concrete, cracks and

other non-homogenous conditions in concrete. Ultrasonic testing can be applied to new and old structures,

slabs,

Columns, walls, fire damaged areas, hydroelectric structures, pipe, prefab and pre-stressed beams, cylinders

and other concrete forms. A wide range of transducers are available.

Ceramics

(ÜRÜN İSMİ YAZILACAK!!!) has been successfully applied to a range of ceramic products--including tile,

refractory bricks and blocks, and kiln furniture--as well as graphite. In an increasing number of refractory

and ceramic applications, the ultrasonic pulse velocity testing technique has been used with positive results.

UPV testing has enabled users to improve their production processes, increase the integrity and quality of

their products, and reduce scrap and reject rates-thereby saving both time and money. In today's economy,

such bottom-line benefits are difficult to ignore.

Frequency range 24 to 500 kHz, based on transducers selec-ted.

Receiver sensitivity 250 micro volts, between 30 kHz and 100 kHz.

Receiver input impedance approximately 100 k Ohms.

Transit time measurement 0.1 to 6553.5 microseconds, direct digital display.

Measurement accuracy 0.1 microseconds.

Transmitter output pulse 1000/500V, 2 microseconds.

Transmitter pulse group rate selectable 1, 3 or 10.

Gain Selection 1, 5, 10, 25, 50, 100, 250, 500

Battery 14 Volt. 4-10 hours continuous use (Lithium Ion).

Display 320 by 240; backlit for daylight use.

Storage 1800 plus readings

Software Windows XP compatible.

Temperature 0° - 50°C

Instr. Weight 6 lbs. (2.75 Kg)

Ship Weight 17 lbs. (7.7 Kg)

Dimensions 4.5" x 8.5" x 10.5" (114.3mm x 223.5mm x 267mm)

TECHNICAL FEATURES

WATER IMPERMEABILITY APPARATUS FOR CONCRETE

EN 12390-8:2009

The device’s

water pressure

during testing

500 kPa ± 50

kPa.

holding water

pressure time

72 Hours

Monitors the quantity of water that

enters the test specimen

Compressor

Water pressure regulation.

Manometer

Corrosion protected materials

ACCESSORIES

Gasket 200 mm / 150 mm

CONCRETE TEST HAMMER

Digital hammers for the quick and easy determination of the strength of concrete.

Product Information

FORE digital test hammers are an advanced, completely automated system for estimating concrete

compressive strength. Its calculation, memory and recording functions allow for quick, easy and accu-

rate test results.

Discard values for multiple test results can be set; the mean, median and compressive strength can also

be calculated. The addition of modern microprocessor technology allows the data to be stored, printed

and transferred to a personal computer for further analysis, or inclusion in your reports.

The unit comes with an integrated alpha “ numeric digital display, and control panel. You can switch

between standard or metric units.

The field printer mounts on the belt for ease of use. Connection to a personal computer is via the RS-

232 interface.

Automatic calculation of mean rebound number, compressive strength and more; Field Printer, PC

connection and software for downloading.

Automatic calculation of mean rebound number, compressive strength and more; Application: Rapid

estimate of concrete strength.

Display 2x16 Trans “ reflective

Construction All Aluminum for rugged construction environment

Operating Temperature 0° to 50° C (32° to 122° F)

Batteries 2 ˜AA™

Ap. Size 100mm x 100mm x 270mm ( 4 x 4 x 10 )

Ap. Weight 1.6 Kg ( 3.5 lbs.)

Printer Size 64mm x 49mm x 31mm ( 2.5 x 1.9 x 1.2 )

Weight: up to 0.270 kg ( 0.6 lbs ) with paper

Battery Internal Lithium ion with 1 yr. approximate life

Charger 100VAC “ 240VAC 5 VDC 3.0A

Operating Temperature 0° to 50° C (32° to 122° F)

Software Windows PC Compatible / USB interface required

Impact energy 2.207 N.m+- 10%

Measurement Range 10 MPa to 70 MPa

Display Resulation Average 0.2 MPa

Compression Strenght MPa

TECHNICAL SPECIFICATIONS

EN 997:2012

EN 14688:2006

EN 997:2012

EN 14688:2006

EN 14688:2006

TESTING APPARATUS FOR STATIC LOAD OF SANITARY

WARE

QUALITY STANDARDS

Fixation of wall hung WC pans and wash basins Laying wooden beam 100 mm

Cross Section 100 mm

TEST ARRANGEMENT

LOADING MECHANISM

Vertical load 1.5 ± 0.01 kN

Non-Corroding protected materials

TESTING EQUIPMENT FOR WC FLUSH

EN 997:2012 WC pans and

WC suites

with integral

trap.

EN 997:2012 5.2.3, 5.2.4,

5.2.6, 5.7.2.4,

5.7.2.5,

5.7.2.7, 6.10

EN 997:2012 Annex A

EN 997:2012 Annex C

QUALITY STANDARDS

Pressure transducer

Non-Corroding Protected Materials

220 V - 50 Hz Power Supply

EQUIPMENT FOR DETERMINATION OF FREEZE/THAW

RESISTANCE OF MASONRY CLAY UNITS AND PAVING BRICKS

QUALITY STANDARDS

EN 1344:2013 clauses 4.2.2, annex C

EQUIPMENT FOR TESTING CERAMIC TILE ANTI-SLIP PROPERTY - SLIPPERI-

NESS METERING PLATFORM

TECHNICAL SPECIFICATIONS

DIN 51130:2014-

02

Workrooms and fields of

activities with slip dan-

ger

DIN 51097:1992-

11 wet-loaded barefoot are-

as;

Panel Holder

Dimansions 100 cm x 50

cm

Inclination

precision

0,1°

Range of

working an-

gles

0°-45°.

QUALITY STANDARDS

Sturdy construction

Actuator Controlling System

Non-corroding or corrosion protected materials

220-230 V - 50 Hz. Power supply

ACCESSORY

Operator shoes DIN 51130:2014-02

Inclination precision 0,1°

Range of working angles 0°-45°.

Sole material IRHD hardness 72 ± 2

Calibration boards DIN 51130:2014-02

VENTILATED DRYING OVEN

Inner chamber volume 0.75 m3

Temperature 50 °C - up to 250 °C

Thermostatic control 110 °C within ± 5 °C

Power supply 220 V - 50 Hz

QUALITY STANDARDS

Forced air circulation

Non-corroding materials

Digital display

Over-temperature safety

Perforated shelves of non-corroding materials.

TECHNICAL SPECIFICATIONS

EN 932-5:2012 Standards for testing for

general properties

EN 932-5:2012/

AC:2014 Standards for testing for

general properties

EN 1097-5:2008 Tests for mechanical and

physical properties

DRYING OVEN WITH NATURAL CONVECTION

Inner chamber volume 0.5 m3

Adjustable Temperature 50 °C to - up to 290 C

Thermostatic control 110 °C within ± 5 °C

Power supply 220—230 V - 50 Hz

QUALITY STANDARDS

Natural convection

Non-corroding materials

Digital display

Digital thermoregulation

Over-temperature safety

Perforated shelves of non-corroding materials. Electronic timer

TECHNICAL SPECIFICATIONS

EN 772-11:2011 Determination of water

absorption

EN 772-3:1998 Determination of net

volume and percentage

of voids

EN 539-2:2013 Determination of physi-

cal characteristics

EN ISO 10545 Series of international

standards on ceramic