BEFORE YOU BEGIN
Verify that input volts match available supply voltage
Use with single motor applications only
Install where no saw dust or metal can enter the enclosure
Verify your motor will operate on 1 phase 208 / 240 volts.
CFW10
Connect 3 Phase LinesConnect Single Phase LinesMount Securely
Ramp Up to SpeedPress StartConnect Power
1 2 3
4 5 6
Call Us for Support(Toll-Free) 1-877-474-8209
This quick start guide has been created by TEMCo Industrial Power Supply™ to provide you with easy to understand instructions on how to install your CFW10 variable frequency drive.
TE TEMCoINDUSTRIAL POWER SUPPLY
FREQUENCY MOTOR SPEED
60 100%45 75%30 50%15 25%
QUICK START GUIDECFW10
Step 1 - Mount the Drive Securely• Drive must be mounted such as to prevent metal shavings or sawdust from entering the unit.• Drives are for indoor use only. Use a weatherproof enclosure for outdoor instillations.• Allow at least 5 inches of space all around the drive for proper ventilation.
Step 2 - Single Phase Supply• Use a wire size appropriate for drive supply amps. Consult an electrician if you are unsure.• Strip approximately 3/8” from the end of the wire and be sure that wire is seated fully in terminal before tightening.• Be sure to ground drive and enclosure.
Step 3 - Three Phase Load• Use wire size appropriate for load amps. Consult an electrician if you are unsure.• Strip approximately 3/8” from the end of the wire and be sure that wire is seated fully in terminal before tightening.
Step 4 - Power On• 120 and 240 volt drives may be wired with a plug, or hardwired to your circuit panel.• When using a plug, select one rated for the voltage and amperage of your drive.• When hardwiring your unit, most building codes require a mechanical disconnect to be installed within sight of the unit.
Step 5 - Startup• Press the Start / Stop button, the motor will begin to accelerate.• When starting your drive for the first time, the speed will be very slow. After ramping up to your desired speed, the drive will remember your settings and automatically accelerate to that speed on startup.• Press the Start / Stop button again to stop the motor.
Step 6 - Ramp to Speed• Press the up and down arrow keys to change the motor speed.• The display on the unit shows the output frequency of the drive. The chart below shows the relationship between frequency and motor speed.
Directions
For more advanced features, or further support call us toll-free at 1-877-474-8209