Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc....

190
Non-Confidential Business Information (Non-CBI) Certification Test Report Travis Industries, Inc. Model: Medium Flush Wood Insert Wood-Fired Fireplace Insert Prepared for: Travis Industries, Inc. 4800 Harbour Pointe Blvd SW Mukilteo, WA 98275 Prepared by: OMNI-Test Laboratories, Inc. 13327 NE Airport Way Portland, OR 97230 (503) 643-3788 Test Period: April 28, 2020 – April 30, 2020 Report Date: May 20, 2020 Report Number: 0028WN123E All data and information contained in this report are confidential and proprietary to Travis Industries, Inc. Its significance is subject to the adequacy and representative character of the samples and to the comprehensiveness of the tests, examinations, or surveys made. The contents of this report cannot be copied or quoted, except in full, without specific, written authorization from Travis Industries, Inc. and OMNI-Test Laboratories, Inc. No use of the OMNI-Test Laboratories, Inc. name, logo, or registered mark (O-TL) is permitted, except as expressly authorized by OMNI-Test Laboratories, Inc. in writing.

Transcript of Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc....

Page 1: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Non-Confidential Business Information (Non-CBI)

Certification Test Report Travis Industries, Inc.

Model: Medium Flush Wood InsertWood-Fired Fireplace Insert

Prepared for: Travis Industries, Inc. 4800 Harbour Pointe Blvd SW Mukilteo, WA 98275 Prepared by: OMNI-Test Laboratories, Inc. 13327 NE Airport Way Portland, OR 97230 (503) 643-3788

Test Period: April 28, 2020 – April 30, 2020

Report Date: May 20, 2020

Report Number: 0028WN123E

All data and information contained in this report are confidential and proprietary to Travis Industries, Inc. Its significance is subject to the adequacy and representative character of the samples and to the comprehensiveness of the tests, examinations, or surveys made. The contents of this report cannot be copied or quoted, except in full, without specific, written authorization from Travis Industries, Inc. and OMNI-Test Laboratories, Inc. No use of the OMNI-Test Laboratories, Inc. name, logo, or registered mark (O-TL) is permitted, except as expressly authorized by OMNI-Test Laboratories, Inc. in writing.

Page 2: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

AUTHORIZED SIGNATORIES

This report has been reviewed and approved by the following authorized signatories:

Evaluator:

__________________________ Bruce Davis, Testing Manager OMNI-Test Laboratories, Inc.

Reviewer:

___________________________ Alex Tiegs, QA Administrator OMNI-Test Laboratories, Inc.

________________________________________________________________________Alex Tiegs, QA AdAdAdAdAdAdAdAdAdAdAdAdAdAddministrator OMNI-Test Laborooooooooooooo atories, Inc.

___________ ____________________________________________________________________________________________________________________ _Bruce Davis Testing Manager

Page 3: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

TABLE OF CONTENTS

PREFACE ............................................................................................................... (3 pages)

1. SAMPLING PROCEDURES AND TEST RESULTS........................................................4 Introduction ..........................................................................................................................5 Individual Run summaries ...................................................................................................6

Summary Tables Table 1 - Particulate Emissions Results ...............................................................................7 Table 2 - Particulate Emissions Results (First Hour)...........................................................7 Table 3 – B415.1 Efficiency and CO Emissions .................................................................7 Table 4 - Test Facility Conditions .......................................................................................8 Table 5 – Kindling and Start-up Fuel Description Summary ..............................................8 Table 6 - Fuel Measurements and Cordwood Descriptions - Test .......................................9 Table 7 - Dilution Tunnel Gas Measurements and Sampling Data .....................................9 Table 10 - Test Configurations ..........................................................................................10

2. PHOTOGRAPHS/APPLIANCE DESCRIPTION/DRAWINGS ......................................11 Fuel Photographs ...............................................................................................................13 Appliance Description .......................................................................................................19

3. TEST DATA BY RUN ......................................................................................................20 Run 1 ..................................................................................................................................26 Run 2 ..................................................................................................................................48 Run 3 ..................................................................................................................................57 Run 4 ..................................................................................................................................76 Run 5 ..................................................................................................................................86

4. QUALITY ASSURANCE/QUALITY CONTROL ........................................................105 Sample Analysis...............................................................................................................107

Calibrations – ASTM E2515, ASTM E3053 ...................................................................118 Example Calculations ......................................................................................................133

5. Firebox Volume ...............................................................................................................145

Appendix A Alt-125 E3053 Letter

Appendix B LABELING & OWNER’S MANUAL

3 of 190

Page 4: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

Section 1 Sampling Procedures and Test Results

4 of 190

Page 5: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

INTRODUCTION

Travis Industries, Inc. retained OMNI to perform U.S. Environmental Protection Agency (EPA) certification testing on the Medium Flush Wood Insert wood stove. The Medium Flush Wood Insert wood stove is a non-Catalytic type room heater. The firebox is constructed of mild steel. Usable firebox volume was measured to be 2.2 cubic feet and the stove is vented through 6” flue collar located on the stove top.

Testing was performed at Travis Industries. The altitude of the laboratory is 108 feet above sea level. The unit was received in good condition and logged in on 4/27/20, then assigned and labeled with OMNI ID #2408. OMNI representative Bruce Davis conducted the certification testing and completed all testing by 4/30/2020.

This report is organized in accordance with the EPA-recommended outline and is summarized in the Table of Contents immediately preceding this section. The results in this report are limited to the item submitted.

SAMPLING PROCEDURE

The Medium Flush Wood Insert wood stove was tested in accordance with the U.S. EPA 40 CFR Part 60, Subpart AAA – Standards of Performance for New Residential Wood Heaters using ASTM E2515, ASTM E3053, and EPA Alt-125. Particulate emissions were measured using sampling trains consisting of two Teflon coated 47mm filters (front and back). See Appendix A for details on EPA Alt-125.

The model Medium Flush Wood Insert was tested for thermal efficiency and carbon monoxide (CO) emissions in accordance with CSA B415.1-10 using Douglas Fir cordwood.

SUMMARY OF RESULTS

The weighted average emissions of the three test runs included in the results indicate a particulate emission rate of 2.45 grams per hour. Particulate emissions were sampled on three of the high burn fuel loads, run one was omitted on a two for one basis. The Medium Flush Wood Insert results are within the EPA 2020 emissions limit of 2.5 g/h for affected products tested with cordwood.

The proportionality results for all 4 test runs were acceptable. Quality check results for each test run are presented in Section 2 of this report.

5 of 190

Page 6: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

INDIVIDUAL RUN SUMMARIES

Run 1 - Test procedures followed to produce a high burn rate with a primary air setting of fully open. Observed burn rate was calculated at 3.62 kg/hr. Emissions results were calculated using particulate sampling from kindling, start-up fuel, and test fuel load combined (cold to hot). Burn rate, and efficiency were calculated using data from the test fuel load only (hot to hot). This test was omitted from the weighted average by conducting two additional high burn tests, only two thirds of results in any burn rate category are used.

Run 2 - Test procedures were followed to produce a Low burn rate with a primary air setting of full closed. Observed burn rate was calculated at 1.16 kg/hr. Emissions and efficiency results were calculated using a hot to hot burn cycle, a coal bed generated by the high burn conducted in test one was used. No anomalies occurred, this test run was determined to be valid for inclusion in the weighted average.

Run 3 - Test procedures followed to produce a high burn rate with a primary air setting of fully open. Observed burn rate was calculated at 4.02 kg/hr. Emissions results were calculated using particulate sampling from kindling, start-up fuel, and test fuel load combined (cold to hot). Burn rate, and efficiency were calculated using data from the test fuel load only (hot to hot). No anomalies occurred, this test run was determined to be valid for inclusion in the weighted average.

Run 4 - Test procedures were followed to produce a Medium burn rate with a primary air setting of 0.375” from full closed. Observed burn rate was calculated at 1.43 kg/hr. Emissions and efficiency results were calculated using a hot to hot burn cycle, a coal bed generated by the high burn conducted in test three was used. No anomalies occurred, this test run was determined to be valid for inclusion in the weighted average.

Run 5 - Test procedures followed to produce a high burn rate with a primary air setting of fully open. Observed burn rate was calculated at 3.90 kg/hr. Emissions results were calculated using particulate sampling from kindling, start-up fuel, and test fuel load combined (cold to hot). Burn rate, and efficiency were calculated using data from the test fuel load only (hot to hot). No anomalies occurred, this test run was determined to be valid for inclusion in the weighted average.

6 of 190

Page 7: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

Table 1 – Particulate Emissions

Run

Burn Rate Calculated from a Hot to Hot burn

cycle (kg/hr dry)

ASTM E2515 Emissions

(g/hr)

ASTM E3053 Weighting Factor

(%)

ASTM E3053 Weighted Emissions

(g/hr)

1 3.62 1.6.03 N/A N/A

2 1.16 2.20 40 0.880

3 4.02 1.4.15 10 0.415

4 1.43 2.07 40 0.828

5 3.90 1.3.24 10 0.324 The sum of weighted particulate emission of 4 test runs: 2.45grams per hour.

Run number 1 was omitted on a two for one basis in the high burn category. 1. Based on a cold start including kindling and start-up fuel.

Table 2 – Particulate Emissions (First Hour)

Run

ASTM E2515 Emissions – First Hour

(g/hr)

2 9.85

3 2.81

4 11.80

5 3.45

Table 3 – B415.1 Efficiency and CO Emissions

RunHeat

Output(BTU/hr)

HHV Efficiency

(%)

LHVEfficiency

(%)

CO Emissions (g/MJ Output)

CO Emissions (g/kg Dry Fuel)

CO Emissions (g/min)

2 15,853 72.9 78.8 6.40 92.39 1.78

3 55,395 72.0 77.8 2.40 34.21 2.33

4 19,250 71.9 77.7 5.67 80.73 1.92

5 52,897 70.3 76.0 2.37 33.06 2.21

Weighted average HHV efficiency of 4 test runs: 72.2%.

Average CO Emissions of four tests: 2.06 g/min

7 of 190

Page 8: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

Table 4 – Test Facility Conditions

Run

Room Temperature (°F)

Barometric Pressure(Hg)

Air Velocity(ft/min)

Before After Before After Before After

2 75 73 29.73 29.67 <50 <50

3 69 78 29.35 29.35 <50 <50

4 79 75 29.35 29.45 <50 <50

5 69 75 29.56 29.58 <50 <50

Table 5 – Kindling and Start-up Fuel Description SummaryDouglas Fir Cordwood

Run

KindlingWeight

Wet Basis(lbs)

Start-upFuel Weight Wet Basis

(lbs)

ResidualStart-upfuel weight (lbs)

1 4.00 6.00 2.4

3 4.40 6.70 2.5

5 4.30 6.20 3.3

8 of 190

Page 9: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Table 6 – Fuel Measurement and Cordwood Description Summary – TEST Douglas Fir Cordwood

Run

Test Fuel Wet Basis

(lbs)

FireboxVolume

(ft3)

Fuel Loading Density Wet

Basis(lbs/ft3)

Test Fuel Dry Basis

(lbs)

Test Fuel Consumed

During Test Dry Basis (lbs)

PieceLength

(in)

1 22.08 2.2 10.0 (18.11+3.60

+4.96) 1

26.67 21.90

4@13

2@15

2 25.91 2.2 11.8 21.68 21.70 4@13

2@15

3 22.44 2.2 10.2 (18.65+3.97

+5.49) 1

28.11 23.2

3@13

2@15

4 26.63 2.2 12.1 22.25 22.3 4@13

2@15

5 21.77 2.2 9.9 (17.88+3.93

+5.02) 1

26.82 21.40

3@13

2@15

1, 2, 3, 4 sum of test load, kindling and start-up fuel weights

Table 7 – Dilution Tunnel Gas Measurements and Sampling Data Summary

RunLength of Test

(min)

Average Dilution Tunnel Gas Measurements

Velocity(ft/sec)

Flow Rate(dscf/min)

Temperature(°F)

2 510 19.76 217.7 89

3 185 20.26 211.8 112

4 425 20.0 215.7 95

5 174 20.01 211.3 110

9 of 190

Page 10: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Table 10 – Test Configurations

Run Startup Procedures Combustion Air

1

Fuel Loading: Kindling and start-up fuel loaded together; a torch was used for 20 seconds to establish a top down fire. At 62 minutes placed fuel load into the firebox. Loading required less than 1 minute to complete. Door: For kindling and start-up fuel, loading door was closed by 30 seconds. Test fuel load: fuel loading door was closed by 5 minutes. Primary Air: Air control fully open for the entire test. Secondary: No user control for secondary air. Fan: Fan turned onto high automatically 51 minutes after lighting fire, remained on high for the entire test. Bypass: Not used

Fully open for entire test.

2

Fuel Loading: Test fuel loaded onto coal bed generated by test number 1 in under 1 minute. Door: Cracked open for 4 minutes 27 seconds, then closed. Primary Air: Fully open, then set to full closed by 14 minutes. Secondary: No user control for secondary air. Fan: On high for entire test. Bypass: Not used for loading test fuel load.

Fully open for first 14 minutes, then set to full closed.

3

Fuel Loading: Kindling and start-up fuel loaded together; a torch was used for 20 seconds to establish a top down fire. At 75 minutes placed fuel load into the firebox. Loading required less than 1 minute to complete. Door: For kindling and start-up fuel, loading door was closed by 30 seconds. Test fuel load: fuel loading door was closed by 2 minute and 20 seconds. Primary Air: Air control fully open for the entire test. Secondary: No user control for secondary air. Fan: Fan turned onto high automatically 56 minutes after lighting fire, remained on high for the entire test. Bypass: Not used

Fully open for entire test.

4

Fuel Loading: Test fuel loaded onto coal bed generated by test number 3 in under 1 minute. Door: Cracked open for 3 minutes 20 seconds, then closed. Primary Air: Fully open, then set to full closed by 11 minutes and 20 seconds. then set to 0.375” from full closed by 14 minutes. Secondary: No user control for secondary air. Fan: On high for entire test. Bypass: Not used for loading test fuel load.

Fully open for first 14 minutes, then

set to 0.375” from full closed.

5

Fuel Loading: Kindling and start-up fuel loaded together; a torch was used for 20 seconds to establish a top down fire. At 64 minutes placed fuel load into the firebox. Loading required less than 1 minute to complete. Door: For kindling and start-up fuel, loading door was closed by 35 seconds. Test fuel load: fuel loading door was closed by 2 minutes and 30 seconds. Primary Air: Air control fully open for the entire test. Secondary: No user control for secondary air. Fan: Fan turned onto high automatically 53 minutes after lighting fire, remained on high for the entire test. Bypass: Not used

Fully open for entire test.

10 of 190

Page 11: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Section 2 Photographs/Appliance Description/Drawings

11 of 190

Page 12: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Travis Industries, Inc. Medium Flush Wood Insert

Test Dates: April 28, 2020 – April 30, 2020

12 of 190

Page 13: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Travis Industries, Inc.Medium Flush Wood Insert

Run 1 – Kindling and start-up fuel Run 1 Kindling and start-up fuel

Run 1 – Ignition of kindling Run 1 Fuel load

13 of 190

Page 14: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Travis Industries, Inc.Medium Flush Wood Insert

Run 1 – Test Fuel Load In Stove Run 1 Remaining Coal bed

Run 2 – Test Fuel Load Run 2 Coal Bed Prior To Loading

14 of 190

Page 15: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 2 – Test Fuel Loaded into Stove Run 2 Remaining Coal After Test

Run 3 – Kindling and start-up fuel Run 3 Ignition of kindling

15 of 190

Page 16: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 3 – Test Fuel Load Run 3 – Test Fuel Loaded into Stove

Run 4 – Coal Bed Prior To Loading Run 4 Test Fuel Load

16 of 190

Page 17: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 4 – Test Fuel Loaded into Stove Run 4 Remaining Coal After Test

Run 5 – Kindling and start-up fuel Run 5 Ignition of kindling

Note: Photo not available for report.

17 of 190

Page 18: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 5 – Coal bed From Start-up and Kindling Run 5 – Test Fuel Load

Run 5 Test Fuel Loaded into Stove

18 of 190

Page 19: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

HEATER DESCRIPTION

Appliance Manufacturer: Travis Industries, Inc.

Wood Stove Model: Medium Flush Wood Insert

Type: Non-Catalytic Wood Burning Insert

WOOD HEATER INFORMATION

Materials of Construction: The unit is constructed primarily of mild steel. The firebox is lined with fire brick that measures 4.5 x 9.0”. The feed door has a 23.0 x 9.20 glass panel and ¼” fiberglass rope gasket.

Air Introduction System: Air is introduced into three different areas of the fire chamber and is controlled by one sliding control rod. Secondary air is introduced into the rear of the fire box through the bottom, it is then channeled up into the secondary air tubes located under the baffle. Air wash air is introduced through an opening in the bottom of the fire box near the front. It is then channeled up to a manifold across the top of the door, air is directed down across the glass and into the fire chamber. A lower primary air orifice is mounted on the firebox floor near the loading door. Air is routed through the bottom of the firebox and into the lower orifice manifold, it is then directed horizontally into the coal bed near the front of the combustion chamber.

Combustion Control Mechanisms: Combustion air control mechanism is a sliding rod with flat plates attached that cover and uncover air inlets when the rod is pushed in or pulled out.

Combustor: N/A

Internal Baffles: A brick baffle is mounted near the top of the fire chamber. A sliding flue bypass is incorporated into the baffle, when opened it allow products of combustion to bypass the baffle system and flow directly to the flue outlet. When closed products of combustion are directed around the front of the baffle system and then back to the flue outlet.

Other Features: Two Fasco 90 CFM room air fans are offered as standard equipment; tested model had a variable speed control mounted in the power supply cord.

Flue Outlet: The 6” diameter flue outlet is located at the rear of the top of the appliance.

WOOD HEATER OPERATING INSTRUCTIONS

Specific Written Instructions: See Section 4 of this report. All markings and instruction materials were reviewed for content prior to printing.

19 of 190

Page 20: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Section 3 Test Data by Run

20 of 190

Page 21: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Fueling instructions for use with ASTM E3053 17Medium Flush Wood High burn Procedure

Test Fuel: Douglas FirFollow the guidelines of the cordwood standard (E3053 17) for correct moisture and weightratios for the Kindling, startup, core and sub loads. The nominal length for the core and subload is 14”.

Startup and kindling loading:Kindling and startup should be loaded as follows for a top down start:

1) 2 medium sized piece (1” x 3” – 2” x 4” by 10” long +/ 1”) of kindling oriented parallel tothe sides of the firebox approximately spaced 6” +/ 1” apart.

2) 2 larger pieces (2” x 2” – 3” x 3” by 10” long +/ 1”) of startup fuel placed perpendicularto the bottom layer. In the middle of the 2 large startup pieces place one medium sizedkindling piece that’s 10” long making sure to leave approximately a ¾” gap betweeneach piece.

3) Repeat step 2 alternating front back/side side (see pic below) until you get 4 5 totallayers depending on the weight restriction of the startup/kindling fuel (leaving enoughextra kindling weight for step 4/5, usually about 0.5 1 lb.)

4) Take 5 pieces of small kindling (1/4” x 1/2” and 5” long +/ 1/2”) and place them on topof the last layer perpendicular in orientation, leaving small gaps 1/8” to ¼” between.

5) Finally, take small kindling pieces (no greater than ¼” x ¼”) and build a cabin style stackon top of the layer of kindling from step 4. Each layer should have 3 4 pieces of kindlingthat are between 4” and 5” in length with 0.5” 3/4” in between each other. Build theselayers until they are about 1” away from the secondary air tubes.

6) With the air control fully open and bypass closed use a hand held propane torch toignite only the top 3 layers of the small kindling cabin at the very top. Use the torch onlyto start the very top on fire (approximately 20 30 seconds). Immediately close the doorafter ensuring the top layer is lit.

21 of 190

Page 22: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

High Fire Test Start:

High fire fuel load should be loaded approximately 1 lb before the bottom of the allowable coalbed range.

The fuel load consists of a bottom layer of 3 pieces and a top layer of 2 pieces. The bottom layershould be comprised of 3 pieces loaded North South with the top layer being only two piecesloaded East West. Upon loading, the bottom layer should have 1” (+/ 1/2”) between eachpiece and centered east west. The top layer should be loaded towards the back of the firebox inan East West fashion leaving a 1” to 2” gap between the two pieces while being centered EastWest.

High Fire Test End:

The test should be ended at the bottom of the allowable weight range.

22 of 190

Page 23: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Fueling instructions for use with ASTM E3053 17Medium Flush Wood Medium and Low burn Procedure

Test Fuel: Douglas FirFollow the guidelines of the cordwood standard (E3053 17) for correct moisture and weightratios for the core and sub loads. The nominal length is 14”

Coal Bed:The coal bed is always a result of running a high burn. As soon as the high burn has beencompleted, move the bigger raw pieces toward the middle and front of the firebox stacked upfor best combustion to get a uniform coal bed prior to the next fuel load.

Settings & Fuel Loading:Low Fire: Fully closedMedium Fire: 3/8” from fully closed.

Fuel Loading:Low and Medium fire should be loaded with a coal bed of approximately 4.0 lbs +/ 0.5 lbs.Level the coal bed before you start sampling and make sure that any large pieces of charcoalget moved to the side to allow room for the fuel load. Keep the bypass closed and the aircontrol fully open.

Low Burn:

The fuel load consists of a bottom layer of 4 pieces and a top layer of 2 pieces. The bottom layershould be comprised of 4 pieces loaded north south with the top layer being 2 pieces loadedeast west. Upon loading, the bottom layer should be loaded so the ends are against the backwall and a 1/2” – 1” gap between all 4 pieces with the wood centered left to right in the firebox.The top rear piece should be loaded east west and fully to the rear of the firebox. The top frontpiece should be loaded such that a 1 to 2 inch gap between it and the east west top piecebehind it.After the fuel is loaded crack the door approximately 1” until secondary combustion is visiblebehind the top front piece. Once visible, close the door (approximately 3 4 minutes after thestart of sampling). After 13 15 minutes from the beginning of sampling, shut down the aircontrol to the fully closed position.

23 of 190

Page 24: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Medium Burn:

The fuel load consists of a bottom layer of 4 pieces and a top layer of 2 pieces. The bottom layershould be comprised of 4 pieces loaded north south with the top layer being only 2 piecesloaded east west. Upon loading, the bottom layer should have 1/2” – 1” gap between all piecesand centered east west. The top rear piece should be loaded all the way to the back, positionedeast west and have approximately a 1 2” gap in between it and the top front piece. After thefuel is loaded crack the door approximately 1” until secondary combustion is visible behind thetop front piece. Once visible, close the door (approximately 3 4 minutes after the start ofsampling). After 13 15 minutes from the beginning of sampling, shut down the air control to the3/8” open medium setting.

24 of 190

Page 25: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Conditioning Data - ASTM E3053/ ASTM E2515Manufacturer:

Model:Tracking No.:

Project No.:Test Date:

Technician:Operation Category:

Elapsed Time (hr)

Flue Gas Temp(° F)

Elapsed Time (hr)

Flue Gas Temp(° F)

0 452.0 26 430.01 418.0 27 403.02 408.0 28 327.03 337.0 29 255.04 213.0 30 190.05 205.0 31 153.06 198.0 32 147.07 195.0 33 210.08 183.0 34 178.09 462.0 35 426.0

10 467.0 36 385.011 352.0 37 306.012 290.0 38 258.013 240.0 39 220.014 220.0 40 186.015 198.0 41 166.016 165.0 42 146.017 409.0 43 144.018 442.0 44 448.019 296.0 45 387.020 243.0 46 367.021 209.0 47 248.022 185.0 48 214.023 182.0 49 202.024 171.0 50 172.025 169.0

Technician Signature:___________________________

Travis IndustriesMedium Flush Wood

24080028WN123E

March - April 2020Travis Industries

Control No. P-SSAR-0003 Low Burn Run 225 of 190

Page 26: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 1

High Burn 1-minute data

Emissions Results (Cold to Hot Cycle)

26 of 190

Page 27: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.46 ft/sec.2408 180 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 215.9 scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 11 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.43 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "HgInitial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102

"H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox Back Firebox Left Firebox

RightAvg. Stove

Surface Stack Filter 1 Dryer Exit 1 Filter 2 Dryer Exit

2 AmbientDraft

("H2O)CO2

(%)CO (%)

0 0.000 0.000 1.08 68 -1.3 1.84 68 -0.88 68 0.100 10.0 66 66 66 66 66 66 67 82 65 82 65 66 -0.013 0.07 0

1 0.163 0.136 0.16 0.14 1.79 68 -1.3 2.22 68 -1.9 69 0.100 88 78 10.0 0 68 66 66 66 66 66 67 81 63 81 65 66 -0.015 0.48 0

2 0.334 0.300 0.17 0.16 1.77 69 -1.2 2.28 68 -1.81 69 0.110 88 89 10.0 0 74 66 66 66 66 68 67 81 63 80 65 67 -0.028 2.01 0.16

3 0.505 0.462 0.17 0.16 1.74 69 -1.3 2.25 68 -1.62 69 0.110 88 88 9.9 -0.1 84 66 66 66 66 70 67 81 62 80 65 67 -0.020 3.75 0.61

4 0.674 0.625 0.17 0.16 1.74 69 -1.5 2.32 68 -1.82 69 0.100 91 93 9.9 0 93 66 66 67 66 72 67 80 62 80 65 67 -0.025 6.68 0.93

5 0.847 0.790 0.17 0.17 1.79 69 -1.5 2.31 69 -1.72 70 0.110 89 90 9.9 0 99 66 67 67 67 73 67 80 62 80 66 67 -0.028 5.06 0.49

6 1.019 0.953 0.17 0.16 1.78 69 -1.6 2.28 69 -1.96 70 0.100 93 93 9.8 -0.1 105 66 67 67 67 74 67 80 62 80 66 67 -0.031 4.43 0.24

7 1.190 1.116 0.17 0.16 1.77 69 -1.5 2.27 69 -1.64 71 0.100 92 93 9.8 0 112 67 67 68 67 76 67 80 62 80 66 67 -0.033 4.62 0.22

8 1.360 1.279 0.17 0.16 1.78 69 -1.5 2.27 69 -1.95 72 0.100 92 93 9.7 -0.1 117 67 67 68 68 77 67 80 62 80 66 67 -0.035 4.56 0.12

9 1.532 1.442 0.17 0.16 1.77 69 -1.3 2.25 69 -1.97 72 0.100 93 93 9.6 -0.1 122 67 68 69 69 79 68 80 62 80 66 67 -0.035 4.31 0.09

10 1.702 1.604 0.17 0.16 1.76 69 -1.6 2.25 69 -1.99 73 0.100 92 93 9.6 0 127 67 68 70 70 80 68 80 62 80 66 67 -0.037 4.17 0.08

11 1.877 1.768 0.18 0.16 1.82 69 -1.8 2.26 69 -1.56 74 0.100 95 94 9.5 -0.1 134 67 69 71 71 82 68 80 62 79 66 67 -0.039 4.94 0.19

12 2.050 1.930 0.17 0.16 1.81 69 -1.4 2.26 69 -1.62 75 0.100 94 93 9.4 -0.1 142 68 70 72 72 85 68 80 62 79 66 67 -0.040 5.38 0.23

13 2.223 2.093 0.17 0.16 1.81 69 -1.5 2.26 69 -1.58 75 0.100 94 93 9.3 -0.1 150 68 70 73 73 87 68 80 62 81 66 67 -0.041 4.86 0.15

14 2.396 2.255 0.17 0.16 1.79 69 -1.6 2.21 69 -1.76 77 0.100 94 93 9.2 -0.1 163 68 71 74 74 90 68 80 62 82 66 67 -0.046 5.08 0.15

15 2.568 2.416 0.17 0.16 1.77 69 -1.7 2.22 69 -2.04 79 0.100 94 92 9.1 -0.1 179 69 72 76 75 94 68 80 62 82 66 67 -0.049 6.3 0.26

16 2.741 2.580 0.17 0.16 1.80 69 -1.8 2.31 69 -1.72 80 0.100 94 94 9.0 -0.1 191 69 73 78 77 98 68 80 62 83 66 67 -0.048 6.18 0.28

17 2.914 2.744 0.17 0.16 1.81 69 -1.8 2.28 69 -1.67 81 0.100 94 94 8.9 -0.1 206 70 74 80 79 102 68 80 62 83 66 67 -0.052 5.68 0.15

18 3.087 2.907 0.17 0.16 1.80 69 -1.5 2.30 69 -1.64 83 0.100 94 94 8.8 -0.1 225 70 76 82 80 107 68 80 62 83 66 67 -0.054 6.56 0.22

19 3.260 3.071 0.17 0.16 1.78 69 -1.6 2.29 69 -1.69 85 0.100 95 95 8.7 -0.1 247 71 77 84 82 112 69 80 62 83 66 67 -0.055 7.3 0.36

20 3.432 3.235 0.17 0.16 1.78 69 -1.9 2.26 69 -1.65 86 0.100 94 95 8.5 -0.2 263 72 79 87 84 117 69 80 62 83 66 68 -0.057 6.99 0.41

21 3.604 3.398 0.17 0.16 1.79 69 -1.6 2.26 69 -1.99 89 0.100 94 95 8.4 -0.1 289 73 80 90 87 124 69 80 62 84 66 68 -0.061 7.43 0.37

22 3.775 3.560 0.17 0.16 1.78 69 -1.5 2.26 69 -1.67 92 0.100 94 94 8.2 -0.2 327 74 82 93 89 133 69 81 62 84 66 68 -0.062 8.24 0.36

23 3.948 3.725 0.17 0.17 1.79 69 -1.7 2.31 69 -1.91 94 0.100 95 96 8.0 -0.2 354 75 84 97 92 140 69 81 62 84 66 68 -0.063 8.12 0.39

24 4.120 3.888 0.17 0.16 1.75 69 -1.8 2.27 69 -2.1 96 0.100 95 95 7.9 -0.1 378 76 86 101 95 147 69 81 62 85 66 68 -0.064 8.17 0.43

25 4.291 4.051 0.17 0.16 1.75 69 -1.9 2.25 69 -2.36 98 0.100 95 95 7.7 -0.2 404 77 89 105 98 155 69 81 62 85 66 68 -0.067 8.03 0.39

26 4.462 4.214 0.17 0.16 1.87 69 -2.4 2.24 69 -2.15 100 0.100 95 95 7.5 -0.2 433 79 91 109 101 163 70 81 63 86 66 68 -0.067 8.49 0.41

27 4.632 4.374 0.17 0.16 1.76 69 -4.3 2.08 69 -3.13 101 0.100 94 94 7.2 -0.3 456 80 94 113 104 169 70 81 63 86 67 69 -0.069 8.47 0.39

28 4.799 4.536 0.17 0.16 1.74 69 -10.1 2.06 69 -6.11 104 0.100 93 95 7.1 -0.1 475 82 97 118 108 176 70 81 63 86 67 69 -0.069 8.83 0.39

29 4.969 4.696 0.17 0.16 1.72 69 -11.3 2.21 69 -9.61 105 0.100 95 94 7.0 -0.1 494 84 100 122 111 182 71 81 63 86 67 69 -0.069 8.95 0.41

30 5.137 4.858 0.17 0.16 1.60 69 -11.5 2.19 69 -10.52 106 0.100 94 95 6.8 -0.2 508 85 103 127 115 188 71 81 63 86 67 69 -0.070 8.77 0.41

31 5.294 5.015 0.16 0.16 1.43 69 -12.1 1.85 69 -7.37 107 0.100 88 93 6.6 -0.2 525 87 107 130 119 194 71 81 64 86 67 69 -0.069 9.05 0.42

32 5.443 5.187 0.15 0.17 1.30 69 -12.3 2.23 69 -1.55 108 0.100 83 101 6.4 -0.2 535 90 110 132 123 198 71 81 64 86 67 69 -0.071 9.02 0.41

33 5.602 5.351 0.16 0.16 1.79 69 -1.4 2.27 70 -1.6 111 0.090 94 102 6.2 -0.2 548 92 115 134 126 203 72 82 64 85 67 69 -0.072 9.38 0.26

34 5.774 5.515 0.17 0.16 1.78 69 -1.7 2.27 70 -1.8 111 0.090 101 102 6.0 -0.2 560 94 119 138 130 208 72 82 64 85 67 69 -0.070 9.8 0.2

35 5.946 5.677 0.17 0.16 1.79 69 -1.4 2.26 70 -1.6 111 0.090 101 101 5.8 -0.2 566 97 123 142 134 212 72 82 64 86 67 69 -0.070 8.54 0.26

36 6.118 5.841 0.17 0.16 1.78 70 -1.7 2.27 70 -1.95 112 0.090 101 102 5.6 -0.2 575 99 126 146 138 217 72 82 65 86 67 69 -0.071 9.03 0.25

37 6.290 6.004 0.17 0.16 1.78 70 -1.7 2.27 70 -1.94 113 0.090 101 102 5.4 -0.2 586 102 130 151 142 222 72 82 65 86 67 70 -0.071 9.65 0.19

38 6.462 6.167 0.17 0.16 1.77 70 -1.4 2.28 70 -2 113 0.090 101 102 5.3 -0.1 593 105 134 156 146 227 72 83 65 86 67 70 -0.071 9.34 0.13

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 12 High Burn Run 1

27 of 190

re:__________________________________ ________________________ _____

Page 28: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.46 ft/sec.2408 180 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 215.9 scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 11 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.43 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "HgInitial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102

"H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox Back Firebox Left Firebox

RightAvg. Stove

Surface Stack Filter 1 Dryer Exit 1 Filter 2 Dryer Exit

2 AmbientDraft

("H2O)CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

39 6.635 6.331 0.17 0.16 1.77 70 -1.4 2.27 70 -2.09 113 0.090 102 102 5.2 -0.1 599 108 138 161 150 231 72 82 65 86 67 70 -0.071 8.99 0.14

40 6.806 6.495 0.17 0.16 1.78 70 -1.4 2.27 70 -1.92 114 0.090 101 102 5.0 -0.2 607 111 141 166 155 236 72 83 66 86 67 70 -0.071 8.85 0.13

41 6.979 6.658 0.17 0.16 1.78 70 -1.5 2.26 70 -2.06 113 0.100 97 96 4.9 -0.1 611 114 144 172 160 240 72 83 66 85 67 70 -0.070 8.79 0.12

42 7.151 6.820 0.17 0.16 1.78 70 -1.7 2.28 70 -2.1 113 0.090 101 101 4.7 -0.2 612 118 148 177 165 244 73 83 66 85 68 70 -0.070 8.53 0.14

43 7.323 6.984 0.17 0.16 1.77 70 -1.6 2.27 70 -2.1 113 0.090 101 102 4.6 -0.1 614 121 151 183 170 248 73 83 66 85 68 70 -0.070 8.77 0.13

44 7.496 7.147 0.17 0.16 1.78 70 -1.4 2.26 70 -2.1 114 0.090 102 102 4.4 -0.2 616 124 155 188 175 252 73 83 66 85 68 70 -0.070 8.8 0.12

45 7.667 7.310 0.17 0.16 1.78 70 -1.4 2.27 70 -1.73 113 0.090 101 102 4.2 -0.2 620 128 158 194 180 256 73 83 67 85 68 70 -0.070 9.04 0.09

46 7.840 7.474 0.17 0.16 1.78 70 -1.7 2.27 70 -1.82 114 0.090 102 102 4.1 -0.1 625 131 162 199 186 261 74 83 67 85 68 71 -0.070 9.36 0.09

47 8.012 7.637 0.17 0.16 1.78 70 -1.6 2.25 70 -1.71 114 0.090 102 102 3.9 -0.2 629 134 165 205 191 265 74 83 67 85 68 70 -0.069 9.23 0.1

48 8.184 7.800 0.17 0.16 1.77 70 -1.7 2.27 71 -1.6 114 0.090 102 101 3.8 -0.1 633 138 169 211 197 270 464 83 67 85 68 71 -0.069 9.13 0.07

49 8.357 7.964 0.17 0.16 1.78 70 -1.5 2.27 71 -1.86 114 0.090 102 102 3.6 -0.2 636 142 173 217 201 274 484 83 68 85 68 71 -0.069 9.14 0.08

50 8.529 8.127 0.17 0.16 1.79 70 -1.4 2.25 71 -1.95 113 0.090 101 101 3.5 -0.1 637 145 177 223 208 278 481 83 68 85 68 71 -0.069 8.76 0.1

51 8.701 8.290 0.17 0.16 1.79 70 -1.7 2.28 71 -2.1 113 0.090 101 101 3.4 -0.1 635 149 180 229 214 281 476 83 68 84 68 71 -0.068 8.65 0.09

52 8.874 8.454 0.17 0.16 1.78 71 -1.6 2.28 71 -1.67 110 0.090 102 102 3.3 -0.1 621 132 171 224 209 271 458 83 68 84 68 71 -0.066 8.52 0.11

53 9.047 8.617 0.17 0.16 1.77 71 -1.6 2.26 71 -2.02 109 0.090 101 101 3.2 -0.1 612 131 168 222 209 268 441 83 68 84 68 71 -0.064 7.98 0.22

54 9.219 8.780 0.17 0.16 1.77 71 -1.6 2.27 71 -1.71 108 0.090 101 101 3.1 -0.1 604 131 166 220 210 266 432 83 68 84 69 72 -0.058 7.54 0.36

55 9.392 8.944 0.17 0.16 1.79 71 -1.4 2.28 71 -2.1 107 0.090 101 101 3.0 -0.1 596 131 166 219 210 264 422 84 69 84 69 72 -0.058 7.49 0.41

56 9.565 9.108 0.17 0.16 1.78 71 -1.4 2.27 71 -2.02 107 0.090 101 101 2.9 -0.1 588 130 166 219 211 263 415 84 69 84 69 72 -0.057 7.26 0.45

57 9.737 9.270 0.17 0.16 1.77 71 -1.4 2.27 71 -1.61 106 0.090 101 100 2.8 -0.1 580 131 166 219 212 262 412 84 69 84 69 72 -0.058 7.52 0.39

58 9.910 9.434 0.17 0.16 1.78 71 -1.7 2.29 71 -1.66 105 0.090 101 101 2.7 -0.1 577 130 167 219 212 261 405 84 69 84 69 72 -0.057 7.31 0.45

59 10.082 9.598 0.17 0.16 1.79 71 -1.5 2.27 71 -1.8 105 0.090 101 101 2.6 -0.1 573 131 168 219 214 261 401 84 69 84 69 72 -0.055 7.1 0.55

60 10.255 9.761 0.17 0.16 1.79 71 -1.7 2.27 71 -2.05 104 0.090 101 101 2.5 -0.1 565 131 169 220 215 260 394 84 69 84 69 71 -0.055 7.06 0.55

61 10.427 9.924 0.17 0.16 1.79 71 -1.5 2.28 72 -2.1 104 0.090 100 100 2.4 -0.1 554 132 170 220 217 259 393 84 69 84 69 72 -0.055 7.03 0.54

62 10.600 10.088 0.17 0.16 1.76 71 -1.4 2.25 72 -1.79 138 0.090 104 104 22.1 19.68 535 133 174 221 218 256 378 84 69 85 69 72 -0.053 6.27 0.58

63 10.771 10.250 0.17 0.16 1.75 71 -1.6 2.26 72 -1.67 138 0.090 103 103 21.6 -0.48 526 133 177 222 219 255 430 84 69 85 70 72 -0.059 4.17 0.38

64 10.943 10.413 0.17 0.16 1.77 71 -1.7 2.27 72 -2.14 134 0.090 103 103 21.3 -0.3 524 134 179 222 221 256 465 85 69 85 70 72 -0.063 4.36 0.45

65 11.114 10.576 0.17 0.16 1.76 71 -1.7 2.24 72 -1.85 126 0.090 102 102 21.2 -0.1 537 135 181 223 222 260 485 85 70 86 70 72 -0.062 5.64 0.4

66 11.288 10.738 0.17 0.16 1.80 72 -1.6 2.25 72 -1.96 128 0.090 104 102 20.9 -0.3 552 136 182 224 223 263 478 85 70 86 69 72 -0.063 7.87 0.58

67 11.462 10.902 0.17 0.16 1.80 72 -1.5 2.29 72 -1.98 124 0.090 103 103 20.7 -0.2 587 136 184 225 224 271 519 85 70 86 70 72 -0.067 11.02 0.63

68 11.636 11.066 0.17 0.16 1.82 72 -1.6 2.28 72 -1.91 124 0.090 103 103 20.5 -0.2 611 137 184 225 225 276 535 85 70 86 70 72 -0.067 11.54 0.5

69 11.809 11.229 0.17 0.16 1.81 72 -1.6 2.27 72 -2.14 125 0.090 103 102 20.2 -0.3 624 138 184 225 226 279 548 85 70 86 70 72 -0.066 11.55 0.49

70 11.981 11.392 0.17 0.16 0.88 72 -4 2.27 72 -1.98 126 0.090 102 102 19.9 -0.3 641 137 184 225 227 283 553 85 70 84 69 73 -0.066 11.9 0.51

71 12.152 11.555 0.17 0.16 1.78 72 -1.5 2.27 72 -2.04 125 0.090 102 102 19.7 -0.2 650 137 183 226 227 285 543 85 70 85 70 72 -0.066 11.31 0.76

72 12.324 11.718 0.17 0.16 1.76 72 -1.5 2.26 72 -1.95 127 0.090 102 102 19.5 -0.2 658 138 182 225 228 286 554 85 70 86 71 73 -0.073 11.23 0.74

73 12.496 11.881 0.17 0.16 1.77 72 -1.7 2.26 72 -1.96 127 0.090 102 102 19.3 -0.2 668 138 182 226 228 288 554 85 71 87 71 73 -0.071 11.78 0.52

74 12.667 12.044 0.17 0.16 1.78 72 -1.5 2.25 72 -2.01 127 0.090 102 102 19.0 -0.3 671 138 181 226 228 289 549 86 71 87 71 73 -0.072 11.24 0.57

75 12.840 12.207 0.17 0.16 1.77 72 -1.5 2.26 73 -1.93 127 0.090 103 102 18.8 -0.2 674 138 180 226 228 289 547 86 71 87 70 73 -0.072 10.88 0.53

76 13.012 12.370 0.17 0.16 1.76 72 -1.6 2.26 73 -1.85 128 0.090 102 102 18.6 -0.2 683 139 180 226 229 291 553 86 71 87 69 72 -0.073 10.98 0.43

77 13.184 12.533 0.17 0.16 1.76 72 -1.5 2.23 73 -2.04 129 0.090 102 102 18.3 -0.3 693 142 181 228 230 295 563 86 71 87 69 72 -0.074 11.31 0.36

78 13.356 12.694 0.17 0.16 1.75 72 -1.6 2.24 73 -1.74 130 0.090 103 101 18.0 -0.3 702 142 180 229 232 297 574 86 71 87 70 72 -0.076 11.73 0.39

79 13.528 12.857 0.17 0.16 1.77 72 -1.6 2.22 73 -1.98 130 0.090 103 103 17.9 -0.1 714 143 180 230 232 300 576 86 72 87 70 72 -0.076 11.99 0.34

Control No. P-SSAR-0003 Page 6 of 12 High Burn Run 1

28 of 190

ature:___e:e:e::e:e:e:e:e _____________________ _____________

Page 29: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.46 ft/sec.2408 180 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 215.9 scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 11 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.43 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "HgInitial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102

"H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox Back Firebox Left Firebox

RightAvg. Stove

Surface Stack Filter 1 Dryer Exit 1 Filter 2 Dryer Exit

2 AmbientDraft

("H2O)CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

80 13.700 13.020 0.17 0.16 1.77 72 -1.7 2.24 73 -2.01 130 0.090 103 103 17.6 -0.3 723 143 179 230 233 302 574 86 72 87 70 73 -0.075 11.97 0.3

81 13.872 13.183 0.17 0.16 1.77 72 -1.6 2.27 73 -2.26 129 0.090 102 102 17.4 -0.2 730 143 178 231 233 303 566 86 72 87 70 73 -0.072 11.57 0.3

82 14.045 13.347 0.17 0.16 1.78 72 -1.8 2.25 73 -2.25 129 0.090 103 103 17.2 -0.2 731 143 177 231 234 303 557 86 72 87 70 73 -0.073 11.58 0.27

83 14.217 13.510 0.17 0.16 1.79 73 -1.6 2.25 73 -2.22 128 0.090 102 102 17.0 -0.2 732 144 176 232 234 304 549 86 72 87 70 74 -0.072 11.41 0.25

84 14.389 13.673 0.17 0.16 1.79 73 -1.5 2.26 73 -2.16 127 0.090 102 102 16.8 -0.2 728 144 175 233 235 303 536 86 73 87 70 74 -0.072 10.57 0.29

85 14.562 13.837 0.17 0.16 1.78 73 -1.6 2.28 73 -2.17 125 0.090 103 103 16.6 -0.2 719 145 174 234 236 302 522 86 73 86 70 74 -0.070 9.77 0.4

86 14.735 14.000 0.17 0.16 1.77 73 -1.8 2.25 73 -1.77 124 0.090 102 102 16.4 -0.2 712 146 174 235 237 301 516 86 73 86 70 74 -0.071 9.36 0.56

87 14.908 14.163 0.17 0.16 1.78 73 -1.8 2.26 73 -1.77 125 0.090 103 102 16.2 -0.2 709 146 173 236 238 300 520 86 73 86 71 74 -0.071 9.65 0.56

88 15.080 14.327 0.17 0.16 1.78 73 -1.7 2.26 73 -1.82 124 0.090 102 103 16.0 -0.2 707 147 173 237 239 301 525 86 74 86 71 74 -0.070 10.03 0.5

89 15.253 14.490 0.17 0.16 1.78 73 -1.6 2.24 73 -1.96 125 0.090 103 102 15.8 -0.2 709 147 173 238 240 301 529 86 74 87 71 74 -0.072 10.48 0.46

90 15.425 14.653 0.17 0.16 1.77 73 -1.5 2.25 73 -1.92 126 0.090 102 102 15.5 -0.3 717 149 172 239 241 304 542 86 74 87 71 74 -0.074 11.26 0.35

91 15.598 14.816 0.17 0.16 1.77 73 -1.7 2.26 73 -2.25 127 0.090 103 102 15.4 -0.1 725 150 172 239 242 306 555 86 74 87 71 74 -0.075 12.2 0.24

92 15.770 14.979 0.17 0.16 1.76 73 -1.5 2.24 73 -2.16 129 0.090 102 102 15.1 -0.3 738 150 171 240 244 309 569 86 74 87 71 74 -0.076 13.13 0.2

93 15.942 15.141 0.17 0.16 1.78 73 -1.7 2.25 74 -2.05 129 0.090 102 102 14.8 -0.3 744 152 171 240 246 311 567 86 75 87 71 75 -0.076 13.19 0.19

94 16.115 15.305 0.17 0.16 1.77 73 -1.8 2.26 74 -2.22 129 0.090 103 103 14.7 -0.1 752 152 171 241 248 313 566 86 75 87 71 75 -0.075 12.77 0.18

95 16.287 15.468 0.17 0.16 1.77 73 -1.7 2.23 74 -2.28 129 0.090 102 102 14.4 -0.3 756 153 171 242 250 314 565 86 75 87 71 75 -0.074 12.61 0.2

96 16.460 15.630 0.17 0.16 1.77 73 -1.5 2.25 74 -2.26 130 0.090 103 102 14.2 -0.2 761 154 171 243 253 316 562 86 75 87 71 75 -0.074 12.53 0.18

97 16.632 15.794 0.17 0.16 1.78 73 -1.5 2.25 74 -2.24 129 0.090 102 103 14.0 -0.2 761 156 171 244 256 318 558 86 76 87 72 74 -0.073 12.15 0.2

98 16.805 15.957 0.17 0.16 1.78 73 -1.6 2.23 74 -2.15 128 0.090 103 102 13.8 -0.2 762 158 170 245 258 319 555 86 76 87 72 73 -0.074 11.95 0.21

99 16.978 16.119 0.17 0.16 1.77 74 -1.7 2.25 74 -1.8 128 0.090 103 102 13.6 -0.2 762 158 171 246 261 320 551 87 76 87 72 73 -0.075 11.67 0.23

100 17.150 16.283 0.17 0.16 1.77 74 -1.6 2.23 74 -2.22 128 0.090 102 103 13.4 -0.2 762 160 172 247 264 321 547 87 76 87 72 73 -0.074 11.58 0.22

101 17.323 16.446 0.17 0.16 1.76 74 -1.7 2.24 74 -2.12 127 0.090 102 102 13.2 -0.2 759 160 172 248 267 321 542 87 76 87 72 74 -0.073 11.39 0.26

102 17.495 16.609 0.17 0.16 1.78 74 -1.7 2.25 74 -2.04 127 0.090 102 102 13.0 -0.2 757 161 172 249 270 322 537 87 76 87 72 74 -0.074 11.25 0.29

103 17.669 16.773 0.17 0.16 1.77 74 -1.5 2.24 74 -1.79 126 0.090 103 103 12.8 -0.2 756 162 172 250 272 322 537 87 77 87 72 75 -0.073 11.24 0.24

104 17.841 16.936 0.17 0.16 1.77 74 -1.7 2.24 74 -2.02 126 0.090 102 102 12.5 -0.3 753 163 173 251 275 323 534 87 77 87 72 76 -0.074 11.18 0.3

105 18.014 17.099 0.17 0.16 1.77 74 -1.7 2.26 74 -2.15 126 0.090 102 102 12.4 -0.1 751 165 173 252 277 324 535 87 77 87 72 75 -0.074 11.21 0.31

106 18.186 17.262 0.17 0.16 1.78 74 -1.8 2.26 74 -2.1 126 0.090 102 102 12.2 -0.2 753 166 174 253 280 325 534 87 77 87 72 75 -0.074 11.16 0.32

107 18.359 17.425 0.17 0.16 1.78 74 -1.6 2.24 74 -1.81 126 0.090 102 102 12.0 -0.2 751 167 174 254 282 326 535 87 77 87 72 75 -0.073 11.28 0.24

108 18.532 17.588 0.17 0.16 1.78 74 -1.8 2.25 75 -2.25 126 0.090 102 102 11.9 -0.1 752 168 175 255 284 327 535 87 77 87 72 76 -0.073 11.32 0.26

109 18.704 17.752 0.17 0.16 1.77 74 -1.6 2.26 75 -2.02 126 0.090 102 102 11.7 -0.2 752 169 175 256 287 328 535 87 78 87 72 76 -0.072 11.51 0.24

110 18.878 17.915 0.17 0.16 1.78 74 -1.7 2.25 75 -2.16 126 0.090 103 102 11.5 -0.2 750 170 176 257 289 328 535 87 78 87 72 76 -0.071 11.58 0.24

111 19.050 18.077 0.17 0.16 1.78 75 -1.6 2.25 75 -1.78 126 0.090 102 101 11.3 -0.2 750 171 176 258 291 329 535 87 78 87 72 77 -0.072 11.69 0.21

112 19.223 18.241 0.17 0.16 1.78 75 -1.5 2.26 75 -2.28 126 0.090 102 102 11.1 -0.2 750 172 177 260 293 330 536 87 78 87 72 76 -0.073 11.73 0.2

113 19.396 18.404 0.17 0.16 1.78 75 -1.6 2.24 75 -1.8 125 0.090 102 102 10.9 -0.2 751 173 178 261 295 332 536 87 78 87 72 77 -0.073 11.77 0.18

114 19.569 18.567 0.17 0.16 1.78 75 -1.5 2.25 75 -2.28 125 0.090 102 102 10.7 -0.2 750 173 178 262 298 332 537 87 78 87 72 74 -0.073 11.91 0.14

115 19.741 18.730 0.17 0.16 1.79 75 -1.5 2.25 75 -1.89 125 0.090 102 102 10.5 -0.2 751 174 179 263 300 333 534 87 78 87 72 76 -0.072 11.89 0.12

Control No. P-SSAR-0003 Page 7 of 12 High Burn Run 1

29 of 190

ure:____________:_________::___:: _______________________________________________________________________ _________________________________________________________________________ ___________________________________________________________________________________________________________

Page 30: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.46 ft/sec.2408 180 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 215.9 scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 11 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.43 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "HgInitial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102

"H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox Back Firebox Left Firebox

RightAvg. Stove

Surface Stack Filter 1 Dryer Exit 1 Filter 2 Dryer Exit

2 AmbientDraft

("H2O)CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

116 19.914 18.893 0.17 0.16 1.78 75 -1.5 2.24 75 -2.27 125 0.090 102 102 10.3 -0.2 752 174 179 265 301 334 534 87 78 87 72 76 -0.072 11.73 0.16

117 20.087 19.056 0.17 0.16 1.78 75 -1.5 2.25 75 -1.83 125 0.090 102 102 10.1 -0.2 752 175 181 266 304 336 533 87 78 88 72 77 -0.070 11.78 0.17

118 20.260 19.220 0.17 0.16 1.78 75 -1.5 2.26 75 -2.24 125 0.090 102 102 9.9 -0.2 752 177 181 268 306 337 533 87 78 88 72 77 -0.070 11.67 0.18

119 20.433 19.383 0.17 0.16 1.77 75 -1.6 2.23 75 -1.84 125 0.090 102 102 9.7 -0.2 758 178 182 269 308 339 535 87 79 88 72 76 -0.071 11.6 0.18

120 20.606 19.546 0.17 0.16 1.78 75 -1.7 2.25 75 -2.28 125 0.090 102 102 9.5 -0.2 761 179 182 271 311 341 533 87 79 88 72 77 -0.071 11.89 0.19

121 20.779 19.710 0.17 0.16 1.78 75 -1.7 2.26 75 -1.79 125 0.090 102 102 9.3 -0.2 760 180 184 272 313 342 532 87 79 88 72 77 -0.070 11.76 0.16

122 20.952 19.873 0.17 0.16 1.78 75 -1.8 2.24 75 -2.28 125 0.090 102 102 9.2 -0.1 759 180 184 274 315 342 529 87 79 88 73 76 -0.070 11.73 0.13

123 21.125 20.035 0.17 0.16 1.78 75 -1.8 2.25 75 -1.79 124 0.090 102 101 9.1 -0.1 756 181 185 275 316 343 528 87 79 88 73 75 -0.070 11.71 0.13

124 21.298 20.199 0.17 0.16 1.79 75 -1.8 2.25 76 -2.28 124 0.090 102 102 8.9 -0.2 756 183 186 276 319 344 526 87 79 88 73 75 -0.070 11.71 0.13

125 21.471 20.362 0.17 0.16 1.79 75 -1.7 2.23 76 -1.85 123 0.090 102 101 8.8 -0.1 753 183 187 277 321 344 522 87 79 87 73 75 -0.070 11.65 0.14

126 21.644 20.525 0.17 0.16 1.78 75 -1.7 2.26 76 -1.93 124 0.090 102 101 8.6 -0.2 752 183 188 279 322 345 521 87 79 87 73 75 -0.069 11.58 0.16

127 21.818 20.689 0.17 0.16 1.78 75 -1.7 2.26 76 -1.81 123 0.090 103 102 8.4 -0.2 749 184 189 280 325 345 520 87 79 87 71 75 -0.070 11.57 0.14

128 21.990 20.853 0.17 0.16 1.79 76 -1.5 2.24 76 -1.94 123 0.090 101 102 8.3 -0.1 748 185 189 282 327 346 520 87 79 87 71 76 -0.069 11.6 0.12

129 22.164 21.016 0.17 0.16 1.78 76 -1.6 2.26 76 -2.29 123 0.090 102 101 8.1 -0.2 748 187 190 283 329 347 520 87 79 87 71 76 -0.069 11.48 0.12

130 22.337 21.179 0.17 0.16 1.78 76 -1.5 2.26 76 -2.15 123 0.090 102 101 7.9 -0.2 749 187 191 284 332 349 517 87 78 87 70 76 -0.069 11.38 0.1

131 22.511 21.343 0.17 0.16 1.79 76 -1.7 2.25 76 -2.07 123 0.090 102 102 7.8 -0.1 747 186 192 286 334 349 516 87 78 87 70 76 -0.067 11.32 0.09

132 22.684 21.506 0.17 0.16 1.79 76 -1.6 2.25 76 -2.29 122 0.090 102 101 7.6 -0.2 746 187 192 287 336 350 514 87 78 87 70 75 -0.068 11.28 0.09

133 22.857 21.669 0.17 0.16 1.79 76 -1.5 2.26 76 -2.26 122 0.090 102 101 7.4 -0.2 747 188 193 288 338 351 515 87 77 88 71 76 -0.067 11.26 0.09

134 23.031 21.833 0.17 0.16 1.78 76 -1.6 2.26 76 -1.84 122 0.090 102 102 7.3 -0.1 746 188 194 290 339 351 515 86 77 88 71 76 -0.068 11.26 0.07

135 23.204 21.997 0.17 0.16 1.77 76 -1.7 2.26 76 -2.09 122 0.090 102 102 7.1 -0.2 748 189 194 291 341 353 514 86 77 88 71 76 -0.068 11.32 0.08

136 23.377 22.160 0.17 0.16 1.79 76 -1.8 2.25 76 -2.17 122 0.090 102 101 7.0 -0.1 749 189 195 292 343 354 515 86 76 88 70 76 -0.068 11.33 0.09

137 23.551 22.324 0.17 0.16 1.79 76 -1.6 2.25 76 -1.93 122 0.090 102 102 6.8 -0.2 751 190 196 294 344 355 514 86 76 88 70 76 -0.068 11.31 0.1

138 23.724 22.487 0.17 0.16 1.78 76 -1.5 2.25 76 -2.26 121 0.090 102 101 6.7 -0.1 749 189 196 295 346 355 510 86 76 88 70 76 -0.067 11.16 0.11

139 23.898 22.650 0.17 0.16 1.78 76 -1.8 2.24 76 -1.81 121 0.090 102 101 6.6 -0.1 747 190 197 296 348 356 509 86 75 88 70 76 -0.068 10.86 0.14

140 24.071 22.814 0.17 0.16 1.79 76 -1.5 2.24 77 -2.21 121 0.090 102 102 6.4 -0.2 744 190 198 297 349 356 506 86 75 88 71 75 -0.067 10.74 0.15

141 24.245 22.976 0.17 0.16 1.78 76 -1.5 2.24 77 -1.97 120 0.090 102 100 6.3 -0.1 741 191 198 297 351 356 504 86 75 87 71 76 -0.066 10.65 0.15

142 24.418 23.139 0.17 0.16 1.78 76 -1.6 2.25 77 -1.81 120 0.090 101 101 6.2 -0.1 737 190 199 298 352 355 499 86 75 87 71 76 -0.068 10.41 0.18

143 24.591 23.303 0.17 0.16 1.79 76 -1.7 2.24 77 -2.03 119 0.090 101 101 6.1 -0.1 734 191 199 299 354 355 493 86 74 87 71 76 -0.068 10.17 0.22

144 24.765 23.466 0.17 0.16 1.79 77 -1.5 2.24 77 -2.09 119 0.090 102 101 5.9 -0.2 730 190 200 300 355 355 491 86 74 87 70 76 -0.068 10.1 0.23

145 24.939 23.629 0.17 0.16 1.79 77 -1.6 2.25 77 -1.83 119 0.090 102 101 5.8 -0.1 727 191 201 300 357 355 490 86 74 87 70 76 -0.068 10.04 0.24

Control No. P-SSAR-0003 Page 8 of 12 High Burn Run 1

30 of 190

ure:___________________________________________ __________________________ ____

Page 31: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.46 ft/sec.2408 180 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 215.9 scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 11 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.43 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "HgInitial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102

"H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox Back Firebox Left Firebox

RightAvg. Stove

Surface Stack Filter 1 Dryer Exit 1 Filter 2 Dryer Exit

2 AmbientDraft

("H2O)CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

146 25.112 23.793 0.17 0.16 1.78 77 -1.8 2.24 77 -2.21 118 0.090 101 101 5.7 -0.1 724 191 202 301 358 355 490 86 74 87 70 76 -0.067 10 0.25

147 25.286 23.956 0.17 0.16 1.79 77 -1.8 2.24 77 -1.82 118 0.090 102 101 5.6 -0.1 720 191 202 301 359 355 488 86 73 87 69 76 -0.067 9.88 0.25

148 25.460 24.119 0.17 0.16 1.80 77 -1.6 2.25 77 -2.32 118 0.090 102 101 5.5 -0.1 718 192 203 302 360 355 484 86 73 87 69 75 -0.067 9.74 0.26

149 25.633 24.283 0.17 0.16 1.79 77 -1.5 2.25 77 -1.84 117 0.090 101 101 5.4 -0.1 714 193 203 302 361 355 481 86 73 88 69 75 -0.067 9.69 0.28

150 25.808 24.445 0.18 0.16 1.79 77 -1.8 2.24 77 -2.3 117 0.090 102 100 5.2 -0.2 711 193 204 302 362 354 478 86 73 88 69 76 -0.067 9.57 0.3

151 25.981 24.608 0.17 0.16 1.80 77 -1.6 2.25 77 -1.85 116 0.090 101 101 5.1 -0.1 708 193 204 302 363 354 476 86 72 88 69 75 -0.066 9.5 0.31

152 26.156 24.772 0.17 0.16 1.80 77 -1.5 2.24 77 -2.24 116 0.090 102 101 5.0 -0.1 705 193 205 303 364 354 475 86 72 88 69 75 -0.067 9.39 0.32

153 26.329 24.934 0.17 0.16 1.79 77 -1.7 2.24 77 -2.3 116 0.090 101 100 4.9 -0.1 701 193 205 303 365 353 473 85 72 88 69 76 -0.066 9.26 0.34

154 26.503 25.097 0.17 0.16 1.78 77 -1.5 2.24 77 -1.9 116 0.090 102 101 4.8 -0.1 697 194 206 303 366 353 471 85 72 88 69 76 -0.066 9.19 0.35

155 26.677 25.261 0.17 0.16 1.79 77 -1.8 2.24 77 -2.22 116 0.090 102 101 4.7 -0.1 694 194 206 304 366 353 469 85 71 88 69 76 -0.066 9.09 0.39

156 26.851 25.424 0.17 0.16 1.80 77 -1.6 2.23 77 -1.85 115 0.090 101 100 4.6 -0.1 689 193 206 304 366 352 465 85 71 87 69 76 -0.065 9.05 0.41

157 27.025 25.587 0.17 0.16 1.79 77 -1.5 2.22 77 -1.83 115 0.090 101 100 4.5 -0.1 686 193 206 304 367 351 464 85 71 87 69 77 -0.065 9.03 0.43

158 27.199 25.750 0.17 0.16 1.80 77 -1.5 2.38 77 -2.02 114 0.090 101 100 4.4 -0.1 682 193 207 305 367 351 462 85 71 87 69 77 -0.065 8.99 0.44

159 27.373 25.915 0.17 0.16 1.80 77 -1.7 2.29 77 -1.95 114 0.090 101 102 4.3 -0.1 678 195 207 305 367 350 461 85 71 87 69 76 -0.064 8.94 0.45

160 27.546 26.079 0.17 0.16 1.79 77 -1.6 2.29 77 -1.95 114 0.090 101 101 4.3 0 675 195 207 305 367 350 458 85 70 87 69 75 -0.065 8.87 0.48

161 27.721 26.244 0.18 0.16 1.79 77 -1.6 2.29 77 -1.96 114 0.090 102 102 4.2 -0.1 671 195 208 306 367 349 459 85 70 87 69 75 -0.064 8.97 0.49

162 27.894 26.409 0.17 0.16 1.79 77 -1.7 2.28 77 -2.08 114 0.090 101 102 4.1 -0.1 669 195 208 306 367 349 457 85 70 87 69 75 -0.064 9 0.5

163 28.069 26.574 0.18 0.17 1.79 77 -1.7 2.28 77 -2.4 114 0.090 102 102 4.0 -0.1 668 196 209 306 367 349 459 85 70 87 69 74 -0.065 9.06 0.48

164 28.242 26.738 0.17 0.16 1.79 77 -1.5 2.27 78 -2 113 0.090 101 101 3.9 -0.1 667 196 209 307 367 349 456 86 70 87 69 74 -0.065 9.14 0.44

165 28.416 26.903 0.17 0.16 1.79 77 -1.8 2.28 78 -2.15 113 0.090 101 101 3.8 -0.1 666 195 210 307 367 349 458 86 70 87 69 75 -0.065 9.27 0.41

166 28.590 27.068 0.17 0.17 1.79 77 -1.6 2.26 78 -2.18 113 0.090 101 101 3.7 -0.1 665 196 211 308 366 349 458 85 69 87 69 74 -0.065 9.29 0.39

167 28.764 27.232 0.17 0.16 1.79 78 -1.8 2.28 78 -2.46 114 0.090 101 101 3.6 -0.1 666 196 211 309 366 350 456 85 69 88 69 74 -0.065 9.36 0.37

168 28.938 27.397 0.17 0.16 1.79 77 -1.6 2.28 78 -2.4 113 0.090 101 101 3.5 -0.1 665 196 212 309 366 350 457 85 69 87 69 74 -0.065 9.39 0.37

169 29.111 27.562 0.17 0.17 1.80 78 -1.5 2.28 78 -2.41 113 0.090 101 101 3.4 -0.1 665 197 212 310 365 350 457 85 69 87 69 74 -0.065 9.37 0.37

170 29.286 27.726 0.18 0.16 1.79 78 -1.8 2.27 78 -2.26 113 0.090 102 101 3.3 -0.1 666 196 213 311 365 350 455 85 69 87 69 75 -0.065 9.29 0.4

171 29.460 27.890 0.17 0.16 1.78 78 -1.8 2.27 78 -2.42 113 0.090 101 101 3.2 -0.1 666 195 214 312 364 350 453 85 69 87 69 76 -0.065 9.31 0.4

172 29.634 28.055 0.17 0.16 1.79 78 -1.8 2.27 78 -2.45 113 0.090 101 101 3.1 -0.1 664 195 215 313 364 350 453 85 69 87 69 76 -0.064 9.37 0.42

173 29.808 28.220 0.17 0.16 1.80 78 -1.5 2.27 78 -2.26 113 0.090 101 101 3.1 0 663 195 215 314 363 350 453 85 69 87 69 76 -0.063 9.36 0.42

174 29.982 28.384 0.17 0.16 1.79 78 -1.7 2.27 78 -2.36 112 0.090 101 101 3.0 -0.1 663 195 216 315 362 350 453 85 68 87 70 77 -0.064 9.5 0.37

175 30.156 28.548 0.17 0.16 1.79 78 -1.7 2.27 78 -2.06 112 0.090 101 101 2.9 -0.1 663 195 217 315 362 350 453 85 68 87 70 77 -0.064 9.57 0.36

176 30.330 28.713 0.17 0.17 1.81 78 -1.7 2.26 78 -2.11 112 0.090 101 101 2.8 -0.1 662 195 218 316 361 350 452 85 68 87 70 76 -0.064 9.68 0.34

177 30.505 28.877 0.18 0.16 1.79 78 -1.5 2.25 78 -2.48 113 0.090 102 101 2.7 -0.1 662 195 220 317 361 351 452 85 68 87 70 75 -0.064 9.63 0.35

178 30.679 29.041 0.17 0.16 1.80 78 -1.5 2.26 78 -2.01 112 0.090 101 101 2.6 -0.1 661 195 221 318 360 351 453 85 68 87 70 75 -0.063 9.59 0.34

179 30.854 29.205 0.18 0.16 1.79 78 -1.8 2.27 78 -2.26 112 0.090 102 101 2.5 -0.1 662 195 223 319 360 352 451 85 68 87 70 75 -0.063 9.53 0.35

180 31.028 29.370 0.17 0.17 1.80 78 -1.5 2.27 78 -2.27 112 0.090 101 101 2.4 -0.1 663 197 224 320 360 353 451 85 68 87 70 76 -0.063 9.53 0.33Avg/Tot 31.028 29.370 0.17 0.16 1.77 73 2.25 73 113 0.092 100 100 286.8 70 86 69 73 -0.065

Control No. P-SSAR-0003 Page 9 of 12 High Burn Run 1

31 of 190

re:______________________________________________________________ ___ _________________________________________________ _______________________________________________________________________________________________________________________________ ___

Page 32: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis Industries Equipment Numbers: Model: Medium Flush Wood

Tracking No.: 2408Project No.: 0028WN122E

Run #: 1Date: 4/28/20

TRAIN 1 (First Hour emissions)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg B. Front filter catch Filter T233S 102.4 99.3 3.1 C. Rear filter catch Filter 0.0 D. Probe catch* Probe 0.0 E. Filter seals catch* Seals 0.0

Sub-Total Total Particulate, mg: 3.1

TRAIN 1 (Post First Hour Change-out)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg B. Front filter catch Filter T227AP 202.1 196.5 5.6 C. Rear filter catch Filter T235S 102.2 98.9 3.3 D. Probe catch* Probe 23 114078.5 114077.3 1.2 E. Filter seals catch* Seals R961 3350.6 3350.1 0.5

Sub-Total Total Particulate, mg: 10.6

Train 1 Aggregate Total Particulate, mg: 13.7

TRAIN 2Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg A. Front filter catch Filter T227BP 197.0 194.0 3.0 B. Rear filter catch Filter T234S 108.9 100.1 8.8 C. Probe catch* Probe 24 114128.8 114127.5 1.3 D. Filter seals catch* Seals R962 3298.1 3297.5 0.6

Total Particulate, mg: 13.7

AMBIENTSample Component Reagent Filter # or Weights

Probe # Final, mg Tare, mg Particulate, mg A. Front filter catch* Filter 0.0

Total Particulate, mg: 0.0

Component Equations: A. Front filter catch Final (mg) - Tare (mg) = Particulate, mg B. Rear filter catch Final (mg) - Tare (mg) = Particulate, mg C. Probe catch Final (mg) - Tare (mg) = Particulate, mg

Technician Signature:_____________________________________________________

*Particulate catch that results in a negative number, is assumed to be zero for probes and seals, negative numbers for filters are assumed to be part of the seal weight.

Wood Heater Lab Data - ASTM E3053 / ASTM E2515

Control No. P-SSAR-0003 High Burn Run 132 of 190

____________________________________________ ____________________________________ _____

Page 33: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN122ETracking No.: 2408

Run: 1Test Date:

Burn Rate 3.31 kg/hr dry

Average Tunnel Temperature 113 degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs 20.46 feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd 12955.8 dscf/hour

Average Delta p 0.092 inches H20Total Time of Test 180 minutes

Total Sample Volume - Vm 0.000 cubic feet 31.028 cubic feet 29.370 cubic feet 10.255 cubic feetAverage Gas Meter Temperature 73 degrees Fahrenheit 73 degrees Fahrenheit 73 degrees Fahrenheit 70 degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd 0.000 dscf 30.285 dscf 28.602 dscf 10.076 dscf

Total Particulates - mn 0 mg 13.7 mg 13.7 mg 3.1 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf 0.00045 grams/dscf 0.00048 grams/dscf 0.00031 grams/dscfTotal Particulate Emissions - ET 0.00 grams 17.58 grams 18.62 grams 3.99 gramsParticulate Emission Rate 0.00 grams/hour 5.86 grams/hour 6.21 grams/hour 1.33 grams/hourEmissions Factor 1.77 g/kg 1.87 g/kg 0.47 g/kg

Difference from Average Total Particulate Emissions 0.52 grams 0.52 grams

Complete Test RunTotal Particulate Emissions - ET 18.10 gramsParticulate Emission Rate 6.03 grams/hourEmissions Factor 1.82 grams/kg

First Hour EmissionsTotal Particulate Emissions - ET 3.99 gramsParticulate Emission Rate 1.33 grams/hourEmissions Factor 0.47 grams/kg

7.5% of Average Total Particulate Emissions 1.36 grams

Technician Signature:_____________________________________________________

OKOKOK

Stove Surface ∆T NOT ACCEPTABLE

OK

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.HECK 10 MIN. INTERVAL PRO-RATPro-Rate Variation

OK

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

Dual Train Comparison Results Are Acceptable

Filter Temps < 90 °F OK

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/28/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

Control No. P-SSAR-0003 High Burn Run 133 of 190

e:____________________________________ _______________________________ ___

Page 34: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 VersionCordwood Fuel Load Calculators 10 lb/ft3 Nominal Load DensityCore 45 65% of Total Load Weight, Remainder 35 55% of Total Load Weight

Values to be input manuallyFor All Usable Firebox Volumes High Fire Test OnlyNominal Required Load Density (wet basis) 10 lb/ft3

Usable Firebox Volume 2.20 ft3

Total Nom. Load Wt. Target 22.00 lbTotal Load Wt. Allowable Range 20.90 to 23.10 lbCore Target Wt. Allowable Range 9.90 to 14.30 lbRemainder Load Wt. Allowable Range 7.70 to 12.10 lb

Mid PointCore Load Pc. Wt. Allowable Range 3.30 to 5.50 lb 4.40Remainder Load Pc. Wt. Allowable Range 2.20 to 12.10 lb 7.15 Fuel Piece Moisture Reading (% dry basis)

Pc. # 1 2 3 Ave.Core Load Piece Wt. Actual 1 3.61 lb In Range 18.6 18.3 19 18.6 In Range 3.04 lb 1.38 kg

2 4.15 lb In Range 24.4 22.5 24.4 23.8 In Range 3.35 lb 1.52 kg3 4.29 lb In Range 23.8 23.8 22 23.2 In Range 3.48 lb 1.58 kg

Core Load Total. Wt. Actual 12.05 lb In RangePc. #

Remainder Load Piece Wt. 1 4.84 lb In Range 25.8 25 23.8 24.9 In Range 3.88 lb 1.76 kg(1 to 3 Pcs.) 2 2.77 lb In Range 19.5 21 17.7 19.4 In Range 2.32 lb 1.05 kg

3 2.42 lb In Range 18.6 19 18.7 18.8 In Range 2.04 lb 0.92 kgRemainder Load Tot. Wt. Act 10.03 lb In Range Total Load Ave. MC (% dry basis) 21.9 In RangeTotal Load Wt. Actual 22.08 lb In Range Total Load Ave. MC % (wet basis) 18.0Core % of Total Wt. 55% In Range 45 65% Total Test Load Weight (dry basis) 18.11 lb 8.22 kgRemainder % of Total Wt. 45% In Range 35 55%Actual Load % of Nominal Target 100% In Range 95 105% Kindling Moisture (% dry basis)Actual Fuel Load Density 10.0 lb/ft3 11.2 11.4 11 11.2 In Range 3.60 lb 1.63 kgKindling and Start up Fuel Start up Fuel Moisture Readings (% dry basis)Maximim Kindling Wt. (20% of Tot. Load Wt.) 4.42 lb 20.3 22.8 19.5 20.9 In Range 4.96 lb 2.25 kgActual Kindling Wt. 4.00 lb In Range 18.1%Maximum Start up Fuel Wt. (30% of Tot. Load Wt.) 6.62 lb Total Wt. All Fuel Added (dry basis) 26.67 lb 12.10 kgActual Start up Fuel Wt. 6.00 lb In Range 27.2% Total Wt. All Fuel Burned (dry basis) 21.9 lb 9.9 kgAllowable Residual Start up Fuel Wt. Range 2.2 to 4.4 lb Mid PointActual Residual Start up Fuel Wt. 2.4 lb In Range 3.3Total Wt. All Fuel Added (wet basis) 32.08 lbHigh Fire Test Run End Point Range Low High Mid PointBased on Fuel Load Wt. (w/tares) 2.0 to 2.4 lb 2.2Actual Fuel Load Ending Wt. 2.4 lb In Range

Pc. Wt. Dry Basis

THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING JURISDICTION AND THE PRESIDENT OF THE SOCIETY. COPYRIGHT ASTM, 100 BARR HARBOR DRIVE, WEST CONSHOHOCKEN, PA 19428. ALL RIGHTS RESERVED.

34 of 190

Page 35: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

35 of 190

Page 36: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

36 of 190

Page 37: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 1

High Burn 1-minute data

Efficiency and Heat Output Results Kindling and start-up fuel removed from calculations

37 of 190

Page 38: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 118 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.90 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "Hg Initial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102 "H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter

1 (ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer Exit

1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

0 19.7 535 133 174 221 218 256 378 84 69 85 69 72 -0.053 6.27 0.58

1 19.2 526 133 177 222 219 255 430 84 69 85 70 72 -0.059 4.17 0.38

2 18.9 524 134 179 222 221 256 465 85 69 85 70 72 -0.063 4.36 0.45

3 18.8 537 135 181 223 222 260 485 85 70 86 70 72 -0.062 5.64 0.4

4 18.5 552 136 182 224 223 263 478 85 70 86 69 72 -0.063 7.87 0.58

5 18.3 587 136 184 225 224 271 519 85 70 86 70 72 -0.067 11.02 0.63

6 18.1 611 137 184 225 225 276 535 85 70 86 70 72 -0.067 11.54 0.5

7 17.8 624 138 184 225 226 279 548 85 70 86 70 72 -0.066 11.55 0.49

8 17.5 641 137 184 225 227 283 553 85 70 84 69 73 -0.066 11.9 0.51

9 17.3 650 137 183 226 227 285 543 85 70 85 70 72 -0.066 11.31 0.76

10 17.1 658 138 182 225 228 286 554 85 70 86 71 73 -0.073 11.23 0.74

11 16.9 668 138 182 226 228 288 554 85 71 87 71 73 -0.071 11.78 0.52

12 16.6 671 138 181 226 228 289 549 86 71 87 71 73 -0.072 11.24 0.57

13 16.4 674 138 180 226 228 289 547 86 71 87 70 73 -0.072 10.88 0.53

14 16.2 683 139 180 226 229 291 553 86 71 87 69 72 -0.073 10.98 0.43

15 15.9 693 142 181 228 230 295 563 86 71 87 69 72 -0.074 11.31 0.36

16 15.6 702 142 180 229 232 297 574 86 71 87 70 72 -0.076 11.73 0.39

17 15.5 714 143 180 230 232 300 576 86 72 87 70 72 -0.076 11.99 0.34

18 15.2 723 143 179 230 233 302 574 86 72 87 70 73 -0.075 11.97 0.3

19 15.0 730 143 178 231 233 303 566 86 72 87 70 73 -0.072 11.57 0.3

20 14.8 731 143 177 231 234 303 557 86 72 87 70 73 -0.073 11.58 0.27

21 14.6 732 144 176 232 234 304 549 86 72 87 70 74 -0.072 11.41 0.25

22 14.4 728 144 175 233 235 303 536 86 73 87 70 74 -0.072 10.57 0.29

23 14.2 719 145 174 234 236 302 522 86 73 86 70 74 -0.070 9.77 0.4

24 14.0 712 146 174 235 237 301 516 86 73 86 70 74 -0.071 9.36 0.56

25 13.8 709 146 173 236 238 300 520 86 73 86 71 74 -0.071 9.65 0.56

26 13.6 707 147 173 237 239 301 525 86 74 86 71 74 -0.070 10.03 0.5

27 13.4 709 147 173 238 240 301 529 86 74 87 71 74 -0.072 10.48 0.46

28 13.1 717 149 172 239 241 304 542 86 74 87 71 74 -0.074 11.26 0.35

29 13.0 725 150 172 239 242 306 555 86 74 87 71 74 -0.075 12.2 0.24

30 12.7 738 150 171 240 244 309 569 86 74 87 71 74 -0.076 13.13 0.2

31 12.4 744 152 171 240 246 311 567 86 75 87 71 75 -0.076 13.19 0.19

32 12.3 752 152 171 241 248 313 566 86 75 87 71 75 -0.075 12.77 0.18

33 12.0 756 153 171 242 250 314 565 86 75 87 71 75 -0.074 12.61 0.2

34 11.8 761 154 171 243 253 316 562 86 75 87 71 75 -0.074 12.53 0.18

35 11.6 761 156 171 244 256 318 558 86 76 87 72 74 -0.073 12.15 0.2

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 11 High Burn Run 1_efficiency

38 of 190

re:________________________________

Page 39: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 118 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.90 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "Hg Initial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102 "H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter

1 (ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer Exit

1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

36 11.4 762 158 170 245 258 319 555 86 76 87 72 73 -0.074 11.95 0.21

37 11.2 762 158 171 246 261 320 551 87 76 87 72 73 -0.075 11.67 0.23

38 11.0 762 160 172 247 264 321 547 87 76 87 72 73 -0.074 11.58 0.22

39 10.8 759 160 172 248 267 321 542 87 76 87 72 74 -0.073 11.39 0.26

40 10.6 757 161 172 249 270 322 537 87 76 87 72 74 -0.074 11.25 0.29

41 10.4 756 162 172 250 272 322 537 87 77 87 72 75 -0.073 11.24 0.24

42 10.1 753 163 173 251 275 323 534 87 77 87 72 76 -0.074 11.18 0.3

43 10.0 751 165 173 252 277 324 535 87 77 87 72 75 -0.074 11.21 0.31

44 9.8 753 166 174 253 280 325 534 87 77 87 72 75 -0.074 11.16 0.32

45 9.6 751 167 174 254 282 326 535 87 77 87 72 75 -0.073 11.28 0.24

46 9.5 752 168 175 255 284 327 535 87 77 87 72 76 -0.073 11.32 0.26

47 9.3 752 169 175 256 287 328 535 87 78 87 72 76 -0.072 11.51 0.24

48 9.1 750 170 176 257 289 328 535 87 78 87 72 76 -0.071 11.58 0.24

49 8.9 750 171 176 258 291 329 535 87 78 87 72 77 -0.072 11.69 0.21

50 8.7 750 172 177 260 293 330 536 87 78 87 72 76 -0.073 11.73 0.2

51 8.5 751 173 178 261 295 332 536 87 78 87 72 77 -0.073 11.77 0.18

52 8.3 750 173 178 262 298 332 537 87 78 87 72 74 -0.073 11.91 0.14

53 8.1 751 174 179 263 300 333 534 87 78 87 72 76 -0.072 11.89 0.12

54 7.9 752 174 179 265 301 334 534 87 78 87 72 76 -0.072 11.73 0.16

55 7.7 752 175 181 266 304 336 533 87 78 88 72 77 -0.070 11.78 0.17

56 7.5 752 177 181 268 306 337 533 87 78 88 72 77 -0.070 11.67 0.18

57 7.3 758 178 182 269 308 339 535 87 79 88 72 76 -0.071 11.6 0.18

58 7.1 761 179 182 271 311 341 533 87 79 88 72 77 -0.071 11.89 0.19

59 6.9 760 180 184 272 313 342 532 87 79 88 72 77 -0.070 11.76 0.16

60 6.8 759 180 184 274 315 342 529 87 79 88 73 76 -0.070 11.73 0.13

61 6.7 756 181 185 275 316 343 528 87 79 88 73 75 -0.070 11.71 0.13

62 6.5 756 183 186 276 319 344 526 87 79 88 73 75 -0.070 11.71 0.13

63 6.4 753 183 187 277 321 344 522 87 79 87 73 75 -0.070 11.65 0.14

64 6.2 752 183 188 279 322 345 521 87 79 87 73 75 -0.069 11.58 0.16

65 6.0 749 184 189 280 325 345 520 87 79 87 71 75 -0.070 11.57 0.14

66 5.9 748 185 189 282 327 346 520 87 79 87 71 76 -0.069 11.6 0.12

67 5.7 748 187 190 283 329 347 520 87 79 87 71 76 -0.069 11.48 0.12

68 5.5 749 187 191 284 332 349 517 87 78 87 70 76 -0.069 11.38 0.1

69 5.4 747 186 192 286 334 349 516 87 78 87 70 76 -0.067 11.32 0.09

70 5.2 746 187 192 287 336 350 514 87 78 87 70 75 -0.068 11.28 0.09

71 5.0 747 188 193 288 338 351 515 87 77 88 71 76 -0.067 11.26 0.09

Control No. P-SSAR-0003 Page 6 of 11 High Burn Run 1_efficiency

39 of 190

re:________________________________

Page 40: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 118 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.90 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "Hg Initial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102 "H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter

1 (ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer Exit

1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

72 4.9 746 188 194 290 339 351 515 86 77 88 71 76 -0.068 11.26 0.07

73 4.7 748 189 194 291 341 353 514 86 77 88 71 76 -0.068 11.32 0.08

74 4.6 749 189 195 292 343 354 515 86 76 88 70 76 -0.068 11.33 0.09

75 4.4 751 190 196 294 344 355 514 86 76 88 70 76 -0.068 11.31 0.1

76 4.3 749 189 196 295 346 355 510 86 76 88 70 76 -0.067 11.16 0.11

77 4.2 747 190 197 296 348 356 509 86 75 88 70 76 -0.068 10.86 0.14

78 4.0 744 190 198 297 349 356 506 86 75 88 71 75 -0.067 10.74 0.15

79 3.9 741 191 198 297 351 356 504 86 75 87 71 76 -0.066 10.65 0.15

80 3.8 737 190 199 298 352 355 499 86 75 87 71 76 -0.068 10.41 0.18

81 3.7 734 191 199 299 354 355 493 86 74 87 71 76 -0.068 10.17 0.22

82 3.5 730 190 200 300 355 355 491 86 74 87 70 76 -0.068 10.1 0.23

83 3.4 727 191 201 300 357 355 490 86 74 87 70 76 -0.068 10.04 0.24

84 3.3 724 191 202 301 358 355 490 86 74 87 70 76 -0.067 10 0.25

85 3.2 720 191 202 301 359 355 488 86 73 87 69 76 -0.067 9.88 0.25

86 3.1 718 192 203 302 360 355 484 86 73 87 69 75 -0.067 9.74 0.26

87 3.0 714 193 203 302 361 355 481 86 73 88 69 75 -0.067 9.69 0.28

88 2.8 711 193 204 302 362 354 478 86 73 88 69 76 -0.067 9.57 0.3

89 2.7 708 193 204 302 363 354 476 86 72 88 69 75 -0.066 9.5 0.31

90 2.6 705 193 205 303 364 354 475 86 72 88 69 75 -0.067 9.39 0.32

91 2.5 701 193 205 303 365 353 473 85 72 88 69 76 -0.066 9.26 0.34

92 2.4 697 194 206 303 366 353 471 85 72 88 69 76 -0.066 9.19 0.35

93 2.3 694 194 206 304 366 353 469 85 71 88 69 76 -0.066 9.09 0.39

94 2.2 689 193 206 304 366 352 465 85 71 87 69 76 -0.065 9.05 0.41

95 2.1 686 193 206 304 367 351 464 85 71 87 69 77 -0.065 9.03 0.43

96 2.0 682 193 207 305 367 351 462 85 71 87 69 77 -0.065 8.99 0.44

97 1.9 678 195 207 305 367 350 461 85 71 87 69 76 -0.064 8.94 0.45

98 1.9 675 195 207 305 367 350 458 85 70 87 69 75 -0.065 8.87 0.48

99 1.8 671 195 208 306 367 349 459 85 70 87 69 75 -0.064 8.97 0.49

100 1.7 669 195 208 306 367 349 457 85 70 87 69 75 -0.064 9 0.5

101 1.6 668 196 209 306 367 349 459 85 70 87 69 74 -0.065 9.06 0.48

102 1.5 667 196 209 307 367 349 456 86 70 87 69 74 -0.065 9.14 0.44

103 1.4 666 195 210 307 367 349 458 86 70 87 69 75 -0.065 9.27 0.41

104 1.3 665 196 211 308 366 349 458 85 69 87 69 74 -0.065 9.29 0.39

105 1.2 666 196 211 309 366 350 456 85 69 88 69 74 -0.065 9.36 0.37

106 1.1 665 196 212 309 366 350 457 85 69 87 69 74 -0.065 9.39 0.37

107 1.0 665 197 212 310 365 350 457 85 69 87 69 74 -0.065 9.37 0.37

Control No. P-SSAR-0003 Page 7 of 11 High Burn Run 1_efficiency

40 of 190

e:________________________________

Page 41: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 118 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.90 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "Hg Initial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102 "H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °F

Vstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter

1 (ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer Exit

1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

108 0.9 666 196 213 311 365 350 455 85 69 87 69 75 -0.065 9.29 0.4

109 0.8 666 195 214 312 364 350 453 85 69 87 69 76 -0.065 9.31 0.4

110 0.7 664 195 215 313 364 350 453 85 69 87 69 76 -0.064 9.37 0.42

111 0.7 663 195 215 314 363 350 453 85 69 87 69 76 -0.063 9.36 0.42

112 0.6 663 195 216 315 362 350 453 85 68 87 70 77 -0.064 9.5 0.37

113 0.5 663 195 217 315 362 350 453 85 68 87 70 77 -0.064 9.57 0.36

114 0.4 662 195 218 316 361 350 452 85 68 87 70 76 -0.064 9.68 0.34

115 0.3 662 195 220 317 361 351 452 85 68 87 70 75 -0.064 9.63 0.35

116 0.2 661 195 221 318 360 351 453 85 68 87 70 75 -0.063 9.59 0.34

117 0.1 662 195 223 319 360 352 451 85 68 87 70 75 -0.063 9.53 0.35

118 0.0 663 197 224 320 360 353 451 85 68 87 70 76 -0.063 9.53 0.33Avg/Tot 0.000 0.000 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! 96.6 74 87 70 75 -0.069

Control No. P-SSAR-0003 Page 8 of 11 High Burn Run 1_efficiency

41 of 190

e:______________________________________ ______________________________________ ____

Page 42: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN122ETracking No.: 2408

Run: 1Test Date:

Burn Rate 3.62 kg/hr dry

Average Tunnel Temperature #DIV/0! degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs #DIV/0! feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd #DIV/0! dscf/hour

Average Delta p #DIV/0! inches H20Total Time of Test 118 minutes

Total Sample Volume - Vm 0.000 cubic feet 0.000 cubic feet 0.000 cubic feet 0.000 cubic feetAverage Gas Meter Temperature 75 degrees Fahrenheit #DIV/0! degrees Fahrenheit #DIV/0! degrees Fahrenheit #DIV/0! degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd 0.000 dscf #DIV/0! dscf #DIV/0! dscf #DIV/0! dscf

Total Particulates - mn 0 mg 0 mg 0 mg 0 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf #DIV/0! grams/dscf #DIV/0! grams/dscf #DIV/0! grams/dscfTotal Particulate Emissions - ET #DIV/0! grams #DIV/0! grams #DIV/0! grams #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hour #DIV/0! grams/hour #DIV/0! grams/hour #DIV/0! grams/hourEmissions Factor #DIV/0! g/kg #DIV/0! g/kg #DIV/0! g/kg

Difference from Average Total Particulate Emissions #DIV/0! grams #DIV/0! grams

Complete Test RunTotal Particulate Emissions - ET #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hourEmissions Factor #DIV/0! grams/kg

First Hour EmissionsTotal Particulate Emissions - ET #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hourEmissions Factor #DIV/0! grams/kg

7.5% of Average Total Particulate Emissions #DIV/0! grams

Technician Signature:_____________________________________________________

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/28/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

#DIV/0!

Filter Temps < 90 °F OKOKOK

#DIV/0!

Stove Surface ∆T OK

OK

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.HECK 10 MIN. INTERVAL PRO-RATPro-Rate Variation

#DIV/0!

Control No. P-SSAR-0003 High Burn Run 1_efficiency

42 of 190

___________________________________

Page 43: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Manufacturer:Travis Industries Technician Signature:Model:edium Flush Wood

Date: 04/28/20Run: 1

Control #: 0028WN122E Test Duration: 118

Output Category: IV

HHV Basis LHV BasisOverall Efficiency 70.7% 76.4%

Combustion Efficiency 97.7% 97.7%Heat Transfer Efficiency 72% 78.2%

Output Rate (kJ/h) 52,188 49,506 (Btu/h)Burn Rate (kg/h) 3.72 8.21 (lb/h)

Input (kJ/h) 73,784 69,992 (Btu/h)

Test Load Weight (dry kg) 7.33 16.14 dry lbMC wet (%) 17.96554553MC dry (%) 21.90

Particulate (g ) #DIV/0!CO (g) 251

Test Duration (h) 1.97

Emissions Particulate COg/MJ Output #DIV/0! 2.45

g/kg Dry Fuel #DIV/0! 34.28g/h #DIV/0! 127.69

lb/MM Btu Output #DIV/0! 5.69

Air/Fuel Ratio (A/F) 9.98

VERSION: 2.2 12/14/2009

Test Results in Accordance with CSA B415.1-09

Wood Heater Efficiency Results - CSA B415.1

43 of 190

re:

B415.1

Page 44: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 VersionCordwood Fuel Load Calculators 10 lb/ft3 Nominal Load DensityCore 45 65% of Total Load Weight, Remainder 35 55% of Total Load Weight

Values to be input manuallyFor All Usable Firebox Volumes High Fire Test OnlyNominal Required Load Density (wet basis) 10 lb/ft3

Usable Firebox Volume 2.20 ft3

Total Nom. Load Wt. Target 22.00 lbTotal Load Wt. Allowable Range 20.90 to 23.10 lbCore Target Wt. Allowable Range 9.90 to 14.30 lbRemainder Load Wt. Allowable Range 7.70 to 12.10 lb

Mid PointCore Load Pc. Wt. Allowable Range 3.30 to 5.50 lb 4.40Remainder Load Pc. Wt. Allowable Range 2.20 to 12.10 lb 7.15 Fuel Piece Moisture Reading (% dry basis)

Pc. # 1 2 3 Ave.Core Load Piece Wt. Actual 1 3.61 lb In Range 18.6 18.3 19 18.6 In Range 3.04 lb 1.38 kg

2 4.15 lb In Range 24.4 22.5 24.4 23.8 In Range 3.35 lb 1.52 kg3 4.29 lb In Range 23.8 23.8 22 23.2 In Range 3.48 lb 1.58 kg

Core Load Total. Wt. Actual 12.05 lb In RangePc. #

Remainder Load Piece Wt. 1 4.84 lb In Range 25.8 25 23.8 24.9 In Range 3.88 lb 1.76 kg(1 to 3 Pcs.) 2 2.77 lb In Range 19.5 21 17.7 19.4 In Range 2.32 lb 1.05 kg

3 2.42 lb In Range 18.6 19 18.7 18.8 In Range 2.04 lb 0.92 kgRemainder Load Tot. Wt. Act 10.03 lb In Range Total Load Ave. MC (% dry basis) 21.9 In RangeTotal Load Wt. Actual 22.08 lb In Range Total Load Ave. MC % (wet basis) 18.0Core % of Total Wt. 55% In Range 45 65% Total Test Load Weight (dry basis) 18.11 lb 8.22 kgRemainder % of Total Wt. 45% In Range 35 55%Actual Load % of Nominal Target 100% In Range 95 105% Kindling Moisture (% dry basis)Actual Fuel Load Density 10.0 lb/ft3 11.2 11.4 11 11.2 In Range 3.60 lb 1.63 kgKindling and Start up Fuel Start up Fuel Moisture Readings (% dry basis)Maximim Kindling Wt. (20% of Tot. Load Wt.) 4.42 lb 20.3 22.8 19.5 20.9 In Range 4.96 lb 2.25 kgActual Kindling Wt. 4.00 lb In Range 18.1%Maximum Start up Fuel Wt. (30% of Tot. Load Wt.) 6.62 lb Total Wt. All Fuel Added (dry basis) 26.67 lb 12.10 kgActual Start up Fuel Wt. 6.00 lb In Range 27.2% Total Wt. All Fuel Burned (dry basis) 21.9 lb 9.9 kgAllowable Residual Start up Fuel Wt. Range 2.2 to 4.4 lb Mid PointActual Residual Start up Fuel Wt. 2.4 lb In Range 3.3Total Wt. All Fuel Added (wet basis) 32.08 lbHigh Fire Test Run End Point Range Low High Mid PointBased on Fuel Load Wt. (w/tares) 2.0 to 2.4 lb 2.2Actual Fuel Load Ending Wt. 2.4 lb In Range

Pc. Wt. Dry Basis

THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING JURISDICTION AND THE PRESIDENT OF THE SOCIETY. COPYRIGHT ASTM, 100 BARR HARBOR DRIVE, WEST CONSHOHOCKEN, PA 19428. ALL RIGHTS RESERVED.

44 of 190

Page 45: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 1

High Burn 10-minute data

Proportional Rate Verification

This data set is presented to verify that when proportional rates are calculated at the required 10-minute interval, required specification that only one reading can be outside of the 90% to 110% are maintained.

45 of 190

Page 46: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 1Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.43 ft/sec.2408 180 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 236.1 scfm Technician Signature:________________________________0028WN122E Recording Interval: 10 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 216.3 scfm28-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 10:28 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.90 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.72 29.73 29.73 "Hg Initial dP 0.100 0.104 0.102 0.070 0.092 0.104 0.104 0.094 0.102 "H2O

OMNI Equipment Numbers: Temp: 68 68 68 68 68 68 68 68 68 °FVstrav 20.67 ft/sec Vscent 21.24 ft/sec Fp 0.973

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

0 0.000 0.000 1.08 68 -1.3 1.84 68 -0.88 68 0.100

10 1.702 1.604 0.17 0.16 1.76 69 -1.6 2.25 69 -1.99 73 0.100 92 92 0

20 3.432 3.235 0.17 0.16 1.78 69 -1.9 2.26 69 -1.65 86 0.100 95 94 0

30 5.137 4.858 0.17 0.16 1.60 69 -11.5 2.19 69 -10.52 106 0.100 95 96 0

40 6.806 6.495 0.17 0.16 1.78 70 -1.4 2.27 70 -1.92 114 0.090 99 102 0

50 8.529 8.127 0.17 0.16 1.79 70 -1.4 2.25 71 -1.95 113 0.090 102 102 0

60 10.255 9.761 0.17 0.16 1.79 71 -1.7 2.27 71 -2.05 104 0.090 101 101 0

70 11.981 11.392 0.17 0.16 0.88 72 -4 2.27 72 -1.98 126 0.090 103 103 0

80 13.700 13.020 0.17 0.16 1.77 72 -1.7 2.24 73 -2.01 130 0.090 103 103 0

90 15.425 14.653 0.17 0.16 1.77 73 -1.5 2.25 73 -1.92 126 0.090 102 103 0

100 17.150 16.283 0.17 0.16 1.77 74 -1.6 2.23 74 -2.22 128 0.090 102 102 0

110 18.878 17.915 0.17 0.16 1.78 74 -1.7 2.25 75 -2.16 126 0.090 102 102 0

120 20.606 19.546 0.17 0.16 1.78 75 -1.7 2.25 75 -2.28 125 0.090 102 102 0

130 22.337 21.179 0.17 0.16 1.78 76 -1.5 2.26 76 -2.15 123 0.090 102 102 0

140 24.071 22.814 0.17 0.16 1.79 76 -1.5 2.24 77 -2.21 121 0.090 102 101 0

150 25.808 24.445 0.17 0.16 1.79 77 -1.8 2.24 77 -2.3 117 0.090 102 101 0

160 27.546 26.079 0.17 0.16 1.79 77 -1.6 2.29 77 -1.95 114 0.090 101 101 0

170 29.286 27.726 0.17 0.16 1.79 78 -1.8 2.27 78 -2.26 113 0.090 101 101 0

180 31.028 29.370 0.17 0.16 1.80 78 -1.5 2.27 78 -2.27 112 0.090 101 101 0Avg/Tot 31.028 29.370 0.17 0.16 1.69 73 2.23 73 112 0.092 100 100 0.0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 8 High Burn Run 1_10 min data

46 of 190

ture:::::_________________________________ ____________________________________ _____________________________________________________________________________________________________

Page 47: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN122ETracking No.: 2408

Run: 1Test Date:

Burn Rate 3.28 kg/hr dry

Average Tunnel Temperature 112 degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs 20.43 feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd 12978.7 dscf/hour

Average Delta p 0.092 inches H20Total Time of Test 180 minutes

Total Sample Volume - Vm 0.000 cubic feet 31.028 cubic feet 29.370 cubic feet 10.255 cubic feetAverage Gas Meter Temperature #DIV/0! degrees Fahrenheit 73 degrees Fahrenheit 73 degrees Fahrenheit 73 degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd #DIV/0! dscf 30.281 dscf 28.603 dscf 10.008 dscf

Total Particulates - mn 0 mg 0 mg 0 mg 0 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf 0.00000 grams/dscf 0.00000 grams/dscf 0.00000 grams/dscfTotal Particulate Emissions - ET 0.00 grams 0.00 grams 0.00 grams 0.00 gramsParticulate Emission Rate 0.00 grams/hour 0.00 grams/hour 0.00 grams/hour 0.00 grams/hourEmissions Factor 0.00 g/kg 0.00 g/kg #DIV/0! g/kg

Difference from Average Total Particulate Emissions 0.00 grams 0.00 grams

Complete Test RunTotal Particulate Emissions - ET 0.00 gramsParticulate Emission Rate 0.00 grams/hourEmissions Factor 0.00 grams/kg

First Hour EmissionsTotal Particulate Emissions - ET 0.00 gramsParticulate Emission Rate 0.00 grams/hourEmissions Factor #DIV/0! grams/kg

7.5% of Average Total Particulate Emissions 0.00 grams

Technician Signature:_____________________________________________________

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/28/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

Dual Train Comparison Results Are Acceptable

Filter Temps < 90 °F OKOKOKOK

Stove Surface ∆T OK

NOT ACCEPTABLE

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.OKPro-Rate Variation

#DIV/0!

Control No. P-SSAR-0003 High Burn Run 1_10 min data47 of 190

________________ _______________________________________ _________________________________________________________________________ _____________________________ _

Page 48: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 2

Low Burn

48 of 190

Page 49: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 2Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.76 ft/sec.2408 510 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.1 scfm Technician Signature:________________________________0028WN123E Recording Interval: 10 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 217.7 scfm28-Apr-20 Dilution Tunnel Static: -0.182 "H2O Post-Test Leak Check (1): 0.000 cfm @ 6 in. Hg

Beginning Clock Time: 13:47 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 6 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.50 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.73 29.67 29.70 "Hg Initial dP 0.082 0.088 0.088 0.080 0.082 0.086 0.088 0.080 0.090 "H2O

OMNI Equipment Numbers: Temp: 78 78 78 78 78 78 78 78 78 °FVstrav 19.55 ft/sec Vscent 20.14 ft/sec Fp 0.971

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

0 0.000 0.000 2.26 78 -1.55 1.54 78 -0.3 109 0.090 25.9 589 199 245 322 355 342 375 82 69 81 64 75 -0.057 2.8 0.45

10 1.637 1.739 0.16 0.17 2.27 78 -1.65 1.78 78 -1.6 132 0.090 103 103 24.0 -1.9 724 188 241 306 339 360 603 86 63 86 70 75 -0.077 12.08 0.56

20 3.276 3.468 0.16 0.17 2.24 78 -2.11 1.76 78 -1.6 107 0.090 101 100 22.3 -1.7 706 172 213 276 311 336 369 85 63 85 71 75 -0.061 6.23 0.51

30 4.917 5.194 0.16 0.17 2.29 78 -1.77 1.75 78 -1.6 104 0.090 101 100 21.1 -1.2 734 159 194 252 282 324 392 84 65 85 68 74 -0.062 10.04 0.33

40 6.568 6.920 0.17 0.17 2.29 78 -1.72 1.75 78 -1.6 102 0.090 101 100 19.8 -1.3 708 148 180 235 261 306 378 83 66 85 70 74 -0.061 9.52 0.49

50 8.218 8.664 0.17 0.17 2.28 78 -2.02 1.81 78 -1.9 101 0.090 101 101 18.6 -1.2 702 142 170 224 247 297 382 83 66 85 72 75 -0.061 10.09 0.33

60 9.866 10.416 0.16 0.18 2.28 78 -1.99 1.81 78 -1.6 103 0.090 101 101 17.3 -1.3 736 135 161 217 236 297 402 84 67 86 72 73 -0.062 11.49 0.16

70 11.515 12.168 0.16 0.18 2.27 78 -1.73 1.81 78 -1.7 103 0.090 101 101 16.0 -1.3 754 131 156 215 228 297 407 85 68 86 73 74 -0.063 12.15 0.13

80 13.160 13.920 0.16 0.18 2.25 78 -1.59 1.80 78 -1.7 104 0.090 101 102 14.6 -1.4 775 129 153 217 228 300 414 85 69 86 73 76 -0.063 12.54 0.11

90 14.805 15.672 0.16 0.18 2.27 78 -2.04 1.82 78 -1.6 102 0.090 101 101 13.5 -1.1 760 126 152 221 225 297 394 85 69 86 73 77 -0.062 11.35 0.16

100 16.450 17.427 0.16 0.18 2.29 78 -1.56 1.82 78 -1.7 101 0.090 101 101 12.4 -1.1 732 125 152 226 220 291 376 85 70 86 73 75 -0.060 10.45 0.28

110 18.096 19.182 0.16 0.18 2.27 79 -2.05 1.81 79 -1.7 99 0.090 101 101 11.5 -0.9 718 125 153 229 217 288 364 84 70 86 74 75 -0.058 10.05 0.32

120 19.745 20.937 0.16 0.18 2.27 79 -1.67 1.81 79 -1.7 98 0.090 101 101 10.7 -0.8 695 124 153 229 214 283 352 84 70 86 74 75 -0.057 9.76 0.36

130 21.392 22.692 0.16 0.18 2.28 79 -1.96 1.81 79 -1.6 97 0.090 101 101 9.9 -0.8 677 123 153 228 211 278 344 84 70 86 74 75 -0.056 9.48 0.4

140 23.041 24.447 0.16 0.18 2.27 79 -2.06 1.82 79 -1.9 95 0.090 100 101 9.2 -0.7 660 122 153 227 209 274 334 84 70 85 74 75 -0.054 9.23 0.5

150 24.693 26.204 0.17 0.18 2.29 79 -1.88 1.80 79 -1.6 94 0.090 101 101 8.5 -0.7 638 122 154 226 207 269 322 84 70 86 74 75 -0.052 9.1 0.52

160 26.343 27.958 0.17 0.18 2.28 79 -2.04 1.81 79 -1.9 94 0.090 100 101 7.8 -0.7 623 121 155 224 206 266 318 84 71 86 74 74 -0.049 9.08 0.52

170 27.994 29.713 0.17 0.18 2.28 79 -1.71 1.80 79 -1.7 93 0.090 100 101 7.2 -0.6 610 121 157 222 206 263 315 84 71 85 74 75 -0.049 9.17 0.46

180 29.644 31.467 0.17 0.18 2.28 79 -1.87 1.80 79 -1.9 93 0.090 100 100 6.5 -0.7 601 121 158 220 207 261 308 84 71 85 73 75 -0.047 8.72 0.56

190 31.295 33.220 0.17 0.18 2.29 79 -1.58 1.81 79 -1.8 91 0.090 100 100 6.1 -0.4 565 120 160 217 207 254 291 83 71 85 74 75 -0.044 7.61 0.92

200 32.946 34.973 0.17 0.18 2.29 79 -1.78 1.80 79 -1.6 90 0.090 100 100 5.6 -0.5 528 119 162 212 207 246 278 83 72 86 73 75 -0.040 7.27 1.11

210 34.597 36.724 0.17 0.18 2.29 79 -1.98 1.80 79 -1.7 88 0.090 100 100 5.3 -0.3 495 119 165 210 206 239 264 83 72 85 73 76 -0.042 7.04 1.25

220 36.248 38.476 0.17 0.18 2.29 79 -1.71 1.79 79 -1.5 88 0.090 100 100 4.9 -0.4 474 119 169 211 204 235 256 83 72 85 73 75 -0.040 7.21 1.34

230 37.899 40.226 0.17 0.18 2.28 79 -1.78 1.80 79 -1.8 86 0.090 100 100 4.7 -0.2 451 119 173 212 203 232 239 83 72 85 73 75 -0.040 6.75 1.45

240 39.549 41.976 0.17 0.18 2.28 79 -1.81 1.80 79 -1.8 85 0.090 100 100 4.3 -0.4 434 120 177 213 203 229 227 83 72 85 73 75 -0.037 6.7 1.79

250 41.197 43.725 0.16 0.17 2.27 79 -1.54 1.80 78 -1.5 84 0.090 99 100 4.1 -0.2 417 121 183 215 202 228 219 83 72 85 73 74 -0.040 6.4 2.12

260 42.846 45.472 0.16 0.17 2.28 79 -1.64 1.79 78 -1.5 84 0.090 99 99 3.9 -0.2 398 121 186 214 204 225 209 82 73 85 73 73 -0.038 6.23 2.13

270 44.494 47.220 0.16 0.17 2.27 78 -1.54 1.79 78 -1.5 83 0.090 100 99 3.6 -0.3 394 121 190 213 208 225 209 82 73 85 73 74 -0.036 7.26 1.78

280 46.141 48.968 0.16 0.17 2.26 78 -1.62 1.79 78 -1.7 83 0.090 99 99 3.4 -0.2 394 121 193 213 214 227 209 82 73 85 73 74 -0.036 7.26 1.87

290 47.789 50.715 0.16 0.17 2.27 78 -1.55 1.78 78 -1.8 83 0.090 100 99 3.2 -0.2 392 122 196 213 219 228 206 82 73 85 73 74 -0.035 6.9 2.01

300 49.436 52.464 0.16 0.17 2.28 78 -1.68 1.80 78 -1.8 83 0.090 99 99 3.0 -0.2 387 123 197 212 220 228 201 82 73 85 73 74 -0.035 6.76 2.16

310 51.084 54.214 0.16 0.18 2.26 78 -1.9 1.80 78 -1.7 82 0.090 99 99 2.8 -0.2 373 123 197 210 219 224 193 82 73 84 73 74 -0.034 5.98 2.43

320 52.732 55.963 0.16 0.17 2.26 78 -1.85 1.80 78 -1.6 82 0.090 99 99 2.6 -0.2 358 123 198 206 218 221 186 82 73 84 73 74 -0.034 5.85 2.27

330 54.378 57.712 0.16 0.17 2.28 78 -1.85 1.79 78 -1.7 81 0.090 99 99 2.5 -0.1 346 121 199 203 215 217 183 82 73 84 73 74 -0.033 5.88 2.23

340 56.025 59.461 0.16 0.17 2.27 78 -1.57 1.80 78 -1.6 81 0.090 99 99 2.3 -0.2 339 121 202 201 211 215 180 82 73 84 72 74 -0.033 6.16 2.34

350 57.673 61.211 0.16 0.18 2.27 78 -2.02 1.80 78 -1.8 81 0.090 99 99 2.1 -0.2 332 120 205 200 208 213 178 82 73 84 72 74 -0.031 5.84 2.37

360 59.319 62.960 0.16 0.17 2.27 78 -1.74 1.81 78 -1.9 81 0.090 99 99 2.0 -0.1 326 119 207 197 205 211 172 82 73 85 72 73 -0.031 5.88 2.11

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 9 Low Burn Run 2

49 of 190

e:_________________________________________

Page 50: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 2Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.76 ft/sec.2408 510 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.1 scfm Technician Signature:________________________________0028WN123E Recording Interval: 10 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 217.7 scfm28-Apr-20 Dilution Tunnel Static: -0.182 "H2O Post-Test Leak Check (1): 0.000 cfm @ 6 in. Hg

Beginning Clock Time: 13:47 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 6 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.50 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.73 29.67 29.70 "Hg Initial dP 0.082 0.088 0.088 0.080 0.082 0.086 0.088 0.080 0.090 "H2O

OMNI Equipment Numbers: Temp: 78 78 78 78 78 78 78 78 78 °FVstrav 19.55 ft/sec Vscent 20.14 ft/sec Fp 0.971

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

370 60.966 64.711 0.16 0.18 2.27 78 -1.56 1.80 78 -1.7 80 0.090 99 99 1.8 -0.2 321 117 205 193 202 208 171 81 73 85 72 73 -0.032 5.68 2.22

380 62.613 66.461 0.16 0.18 2.28 78 -1.7 1.80 77 -1.8 80 0.090 99 99 1.7 -0.1 312 116 201 189 200 204 166 81 73 85 72 73 -0.031 5.49 2.21

390 64.259 68.210 0.16 0.17 2.28 78 -1.97 1.80 77 -1.5 79 0.090 99 99 1.5 -0.2 303 115 198 183 198 199 159 81 73 84 72 73 -0.029 5.44 2.01

400 65.906 69.960 0.16 0.18 2.27 77 -1.82 1.79 77 -1.8 79 0.090 99 99 1.4 -0.1 296 114 195 177 196 196 156 81 73 84 72 73 -0.029 5.47 1.95

410 67.552 71.709 0.16 0.17 2.25 77 -1.71 1.80 77 -1.5 79 0.090 99 99 1.3 -0.1 289 113 193 170 194 192 155 81 74 84 72 73 -0.029 5.61 1.81

420 69.199 73.460 0.16 0.18 2.27 77 -1.97 1.80 77 -1.7 79 0.090 99 99 1.1 -0.2 285 112 191 165 191 189 154 81 74 84 72 73 -0.029 5.54 1.81

430 70.845 75.209 0.16 0.17 2.28 77 -1.55 1.80 77 -1.8 79 0.090 99 99 1.0 -0.1 281 111 191 161 190 187 151 81 74 84 72 73 -0.028 5.53 1.99

440 72.492 76.959 0.16 0.18 2.27 77 -1.78 1.79 77 -1.6 78 0.090 99 99 0.9 -0.1 277 109 191 158 188 185 150 81 74 84 72 73 -0.028 5.18 2.18

450 74.138 78.709 0.16 0.18 2.27 77 -1.92 1.80 77 -1.8 78 0.090 99 99 0.8 -0.1 276 107 191 155 186 183 150 81 73 84 72 73 -0.028 6.16 1.94

460 75.784 80.459 0.16 0.18 2.27 77 -1.85 1.81 77 -1.8 78 0.090 99 99 0.6 -0.2 273 106 190 154 183 181 148 81 74 84 72 73 -0.027 5.55 1.99

470 77.429 82.210 0.16 0.18 2.28 77 -1.73 1.80 77 -1.9 78 0.090 99 99 0.5 -0.1 268 105 190 152 179 179 146 81 73 84 72 73 -0.027 5.54 2.09

480 79.076 83.959 0.16 0.17 2.26 77 -1.64 1.80 77 -1.6 78 0.090 99 99 0.4 -0.1 265 103 191 151 176 177 144 81 73 84 72 73 -0.026 5.34 2.19

490 80.722 85.709 0.16 0.18 2.27 77 -1.52 1.80 77 -1.5 78 0.090 99 99 0.3 -0.1 262 102 190 149 173 175 144 81 73 84 72 73 -0.026 5.39 2.24

500 82.367 87.459 0.16 0.18 2.28 77 -2.03 1.78 77 -1.7 78 0.090 99 99 0.1 -0.2 259 102 189 147 171 174 142 81 73 84 72 72 -0.026 5.09 2.18

510 84.012 89.207 0.16 0.17 2.27 77 -1.94 1.80 77 -1.9 78 0.090 99 99 0.0 -0.1 256 101 187 145 169 172 142 81 73 84 72 73 -0.025 5.25 2.1Avg/Tot 84.012 89.207 0.16 0.17 2.27 78 1.79 78 89 0.090 100 100 170.4 71 85 72 74 -0.042

Control No. P-SSAR-0003 Page 6 of 9 Low Burn Run 2

50 of 190

re:___________________________

Page 51: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis Industries Equipment Numbers: Model: Medium Flush Wood

Tracking No.: 2408Project No.: 0028WN123E

Run #: 2Date: 4/28/20

TRAIN 1 (First Hour emissions)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg B. Front filter catch Filter T236S 105.5 98.3 7.2 C. Rear filter catch Filter 0.0 D. Probe catch* Probe 0.0 E. Filter seals catch* Seals 0.0

Sub-Total Total Particulate, mg: 7.2

TRAIN 1 (Post First Hour Change-out)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg B. Front filter catch Filter T228AP 197.4 193.6 3.8 C. Rear filter catch Filter 0.0 D. Probe catch* Probe 25 114300.7 114299.9 0.8 E. Filter seals catch* Seals R963 4140.3 4138.1 2.2

Sub-Total Total Particulate, mg: 6.8

Train 1 Aggregate Total Particulate, mg: 14.0

TRAIN 2Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg A. Front filter catch Filter T228BP 206.1 193.2 12.9 B. Rear filter catch Filter 0.0 C. Probe catch* Probe 27 114276.1 114275.1 1.0 D. Filter seals catch* Seals R965 3361.1 3360.8 0.3

Total Particulate, mg: 14.2

AMBIENTSample Component Reagent Filter # or Weights

Probe # Final, mg Tare, mg Particulate, mg A. Front filter catch* Filter 0.0

Total Particulate, mg: 0.0

Component Equations: A. Front filter catch Final (mg) - Tare (mg) = Particulate, mg B. Rear filter catch Final (mg) - Tare (mg) = Particulate, mg C. Probe catch Final (mg) - Tare (mg) = Particulate, mg

Technician Signature:_____________________________________________________

*Particulate catch that results in a negative number, is assumed to be zero for probes and seals, negative numbers for filters are assumed to be part of the seal weight.

Wood Heater Lab Data - ASTM E23053 / ASTM E2515

Control No. P-SSAR-0003 Low Burn Run 251 of 190

:_______________________ ______________

Page 52: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN123ETracking No.: 2408

Run: 2Test Date:

Burn Rate 1.16 kg/hr dry

Average Tunnel Temperature 89 degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs 19.76 feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd 13063.8 dscf/hour

Average Delta p 0.090 inches H20Total Time of Test 510 minutes

Total Sample Volume - Vm 0.000 cubic feet 84.012 cubic feet 89.207 cubic feet 9.866 cubic feetAverage Gas Meter Temperature 74 degrees Fahrenheit 78 degrees Fahrenheit 78 degrees Fahrenheit 78 degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd 0.000 dscf 81.273 dscf 85.947 dscf 9.544 dscf

Total Particulates - mn 0 mg 14 mg 14.2 mg 7.2 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf 0.00017 grams/dscf 0.00017 grams/dscf 0.00075 grams/dscfTotal Particulate Emissions - ET 0.00 grams 19.13 grams 18.35 grams 9.85 gramsParticulate Emission Rate 0.00 grams/hour 2.25 grams/hour 2.16 grams/hour 9.85 grams/hourEmissions Factor 1.94 g/kg 1.86 g/kg 3.02 g/kg

Difference from Average Total Particulate Emissions 0.39 grams 0.39 grams

Complete Test RunTotal Particulate Emissions - ET 18.74 gramsParticulate Emission Rate 2.20 grams/hourEmissions Factor 1.90 grams/kg

First Hour EmissionsTotal Particulate Emissions - ET 9.85 gramsParticulate Emission Rate 9.85 grams/hourEmissions Factor 3.02 grams/kg

7.5% of Average Total Particulate Emissions 1.41 grams

Technician Signature:_____________________________________________________

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/28/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

Dual Train Comparison Results Are Acceptable

Filter Temps < 90 °F OKOKOKOK

Stove Surface ∆T NOT ACCEPTABLE

OK

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.OKPro-Rate Variation OK

Control No. P-SSAR-0003 Low Burn Run 252 of 190

_________________________ ___________ _____

Page 53: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Manufacturer: Travis Industries Technician Signature:Model:edium Flush Wood

Date: 04/28/20Run: 2

Control #: 0028WN123E Test Duration: 510

Output Category: II

HHV Basis LHV BasisOverall Efficiency 72.9% 78.8%

Combustion Efficiency 93.5% 93.5%Heat Transfer Efficiency 78% 84.3%

Output Rate (kJ/h) 16,712 15,853 (Btu/h)Burn Rate (kg/h) 1.16 2.55 (lb/h)

Input (kJ/h) 22,918 21,741 (Btu/h)

Test Load Weight (dry kg) 9.83 21.67 dry lbMC wet (%) 16.31799163MC dry (%) 19.50

Particulate (g ) 18.74CO (g) 909

Test Duration (h) 8.50

Emissions Particulate COg/MJ Output 0.13 6.40

g/kg Dry Fuel 1.91 92.39g/h 2.20 106.89

lb/MM Btu Output 0.31 14.86

Air/Fuel Ratio (A/F) 11.98

VERSION: 2.2 12/14/2009

Test Results in Accordance with CSA B415.1-09

Wood Heater Efficiency Results - CSA B415.1

53 of 190

e:

Page 54: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 VersionCordwood Fuel Load Calculators 12 lb/ft3 Nominal Load DensityCore 45 65% of Total Load Weight, Remainder 35 55% of Total Load Weight

Values to be input manuallyFor Usable Firebox Volumes up to 3.0 ft3 Low and Medium Fire

Nominal Required Load Density (wet basis) 12 lb/ft3

Usable Firebox Volume 2.20 ft3

Total Nom. Load Wt. Target 26.4 lbTotal Load Wt. Allowable Range 25.08 to 27.72 lbCore Target Wt. Allowable Range 11.88 to 17.16 lbRemainder Load Wt. Allowable Range 9.24 to 14.52 lb

Mid PointCore Load Fuel Pc. Wt. Allowable Range 3.96 to 6.60 lb 5.28Remainder Load Pc. Wt. Allowable Range 2.64 to 7.92 lb 5.28 Fuel Piece Moisture Reading (% dry basis)

Pc. # 1 2 3 Ave.Core Load Piece Wt. Actual 1 4.34 lb In Range 18.7 18.3 18.8 18.6 In Range 3.66 lb 1.66 kg

2 4.37 lb In Range 20.5 20 18.1 19.5 In Range 3.65 lb 1.66 kg3 4.02 lb In Range 19.2 18.6 19.4 19.1 In Range 3.38 lb 1.53 kg

Core Load Total. Wt. Actual 12.73 lb In RangePc. #

Remainder Load Piece Wt. 1 6.62 lb In Range 20.1 17.7 17.8 18.5 In Range 5.58 lb 2.53 kg(2 or 3 Pcs.) 2 3.13 lb In Range 18.4 19.5 17.8 18.6 In Range 2.64 lb 1.20 kg

3 3.44 lb In Range 23.8 22.6 25.4 23.9 In Range 2.77 lb 1.26 kgRemainder Load Piece Weight Ratio Small/Large 47% In Range 67% Total Load Ave. MC % (dry basis) 19.5 In RangeRemainder Load Tot. Wt. Act 13.18 lb In Range Total Load Ave. MC % (wet basis) 16.3Total Load Wt. Actual 25.91 lb In Range Total Test Load Weight (dry basis) 21.68 lb 9.83 kgCore % of Total Wt. 49% In Range 45 65% Total Fuel Weight Burned During Test Run (dry basis) 21.7 lb 9.83 kgRemainder % of Total Wt. 51% In Range 35 55%Actual Load % of Nominal Target 98% In Range 95 105%Actual Fuel Load Density 11.8 lb/ft3

Allowable Charcoal Bed Wt. Range (lb) 2.6 to 5.1 Mid PointActual Charcoal Bed Wt. 3.7 lb In Range 3.9Actual Fuel Load Ending Wt. 0.0 lb Valid Test 90%Total Wt. of Fuel Burned During Test Run lb. 25.9 lb

Pc. Wt. Dry Basis

THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING JURISDICTION AND THE PRESIDENT OF THE SOCIETY. COPYRIGHT ASTM, 100 BARR HARBOR DRIVE, WEST CONSHOHOCKEN, PA 19428. ALL RIGHTS RESERVED.

54 of 190

Page 55: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

55 of 190

Page 56: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

56 of 190

Page 57: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 3 Non-Particulate Sampling High Burn

57 of 190

Page 58: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.26 ft/sec.2408 185 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 222.0 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.8 scfm29-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 14 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.18 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP 0.086 0.090 0.090 0.078 0.082 0.090 0.094 0.080 0.092 "H2O

OMNI Equipment Numbers: Temp: 70 70 70 70 70 70 70 70 70 °FVstrav 19.76 ft/sec Vscent 20.34 ft/sec Fp 0.971

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

0 0.000 0.000 1.80 71 -0.61 1.99 71 -0.9 70 0.100 11.1 69 69 69 69 69 69 69 83 67 85 67 69 -0.012 0.04 0

1 0.145 0.164 0.15 0.16 2.27 71 -1.54 1.78 71 -1.5 71 0.100 81 87 11.1 0 71 69 69 69 69 69 78 82 66 84 67 69 -0.015 0.31 0.01

2 0.309 0.337 0.16 0.17 2.25 71 -1.97 1.78 72 -1.5 71 0.090 96 97 11.0 -0.1 80 69 70 69 69 71 82 81 66 84 68 69 -0.016 4.31 0.42

3 0.473 0.510 0.16 0.17 2.22 71 -1.96 1.76 72 -1.4 71 0.090 96 97 11.0 0 86 69 70 69 69 73 93 81 67 84 68 69 -0.020 6.72 1

4 0.638 0.684 0.17 0.17 2.31 71 -1.6 1.78 72 -1.7 71 0.090 97 98 11.0 0 92 69 70 70 70 74 107 81 67 83 68 69 -0.023 5.84 0.8

5 0.804 0.857 0.17 0.17 2.30 72 -1.69 1.76 72 -1.7 72 0.090 98 97 10.9 -0.1 97 69 70 70 70 75 120 80 67 83 68 69 -0.027 4.86 0.36

6 0.969 1.030 0.17 0.17 2.29 72 -1.68 1.75 72 -1.4 72 0.090 97 97 10.9 0 104 70 70 70 70 77 136 80 67 83 68 69 -0.029 4.9 0.31

7 1.134 1.202 0.17 0.17 2.26 72 -1.9 1.75 72 -1.6 73 0.090 97 97 10.8 -0.1 110 70 70 71 71 78 147 80 67 83 68 69 -0.031 4.56 0.2

8 1.298 1.374 0.16 0.17 2.26 72 -2.03 1.74 72 -1.7 73 0.090 96 97 10.8 0 115 70 71 72 71 80 153 80 67 83 68 69 -0.031 4.08 0.16

9 1.462 1.546 0.16 0.17 2.24 72 -1.57 1.73 71 -1.4 73 0.090 96 97 10.7 -0.1 119 70 71 72 72 81 156 80 67 83 68 69 -0.031 3.87 0.14

10 1.626 1.717 0.16 0.17 2.22 72 -1.64 1.73 71 -1.6 73 0.090 96 96 10.7 0 124 70 72 73 73 82 157 80 67 83 68 69 -0.031 3.26 0.18

11 1.790 1.891 0.16 0.17 2.26 72 -1.65 1.80 72 -1.5 74 0.090 97 98 10.6 -0.1 129 70 73 74 74 84 161 80 67 83 68 69 -0.033 3.3 0.16

12 1.954 2.065 0.16 0.17 2.25 72 -1.55 1.79 72 -1.6 74 0.090 97 98 10.6 0 134 71 74 75 75 86 170 80 67 83 68 69 -0.034 3.48 0.15

13 2.118 2.239 0.16 0.17 2.26 72 -1.96 1.79 72 -1.5 74 0.090 97 98 10.5 -0.1 140 71 74 77 76 88 174 80 66 83 68 69 -0.034 3.77 0.14

14 2.282 2.413 0.16 0.17 2.23 72 -1.96 1.78 72 -1.4 75 0.090 97 98 10.5 0 146 71 75 78 78 90 183 80 66 83 68 69 -0.038 3.63 0.12

15 2.445 2.586 0.16 0.17 2.23 72 -2.03 1.77 72 -1.8 76 0.090 96 97 10.4 -0.1 159 72 76 79 79 93 205 80 66 83 68 69 -0.041 4.98 0.1

16 2.608 2.759 0.16 0.17 2.23 72 -1.71 1.77 72 -1.7 77 0.090 96 98 10.3 -0.1 173 72 77 80 80 96 221 80 66 83 68 69 -0.042 5.24 0.08

17 2.771 2.931 0.16 0.17 2.21 72 -1.62 1.75 72 -1.6 78 0.090 96 97 10.2 -0.1 185 72 78 81 81 99 232 80 66 83 68 69 -0.044 5.27 0.07

18 2.933 3.103 0.16 0.17 2.20 72 -1.8 1.74 72 -1.6 79 0.090 96 97 10.1 -0.1 195 73 79 83 83 103 246 80 66 83 68 69 -0.046 5.52 0.08

19 3.098 3.278 0.17 0.18 2.30 72 -1.68 1.84 72 -2 80 0.090 98 99 10.0 -0.1 205 73 80 85 85 106 262 80 66 83 68 69 -0.048 6.27 0.17

20 3.264 3.456 0.17 0.18 2.30 72 -2.16 1.83 72 -1.7 82 0.090 98 101 9.9 -0.1 218 74 81 86 86 109 272 80 66 83 68 69 -0.048 6.15 0.17

21 3.429 3.632 0.17 0.18 2.29 72 -1.68 1.83 72 -1.6 83 0.090 98 100 9.8 -0.1 229 75 83 88 88 113 284 80 65 83 68 69 -0.050 5.9 0.18

22 3.594 3.808 0.17 0.18 2.29 72 -1.83 1.83 72 -2 84 0.090 98 100 9.7 -0.1 243 75 84 90 90 116 297 81 65 83 69 69 -0.052 6.53 0.22

23 3.759 3.985 0.17 0.18 2.29 72 -2.08 1.82 72 -1.7 86 0.090 98 101 9.6 -0.1 267 76 86 93 92 123 323 81 65 83 69 69 -0.055 7.35 0.26

24 3.924 4.161 0.17 0.18 2.27 72 -2.13 1.82 72 -1.9 88 0.090 98 100 9.5 -0.1 294 77 87 95 94 129 343 81 65 83 69 69 -0.058 7.86 0.28

25 4.088 4.337 0.16 0.18 2.26 72 -1.68 1.82 72 -1.9 90 0.090 98 100 9.3 -0.2 325 78 89 98 97 137 367 81 65 83 69 70 -0.060 8.14 0.32

26 4.252 4.512 0.16 0.18 2.27 72 -1.83 1.81 72 -1.7 92 0.090 98 100 9.1 -0.2 355 79 92 101 99 145 386 81 65 83 69 70 -0.061 8.68 0.38

27 4.417 4.688 0.17 0.18 2.26 72 -2.05 1.81 72 -1.7 94 0.090 99 101 8.9 -0.2 382 80 94 105 102 153 403 81 65 84 69 70 -0.063 8.45 0.35

28 4.581 4.863 0.16 0.18 2.24 72 -1.93 1.81 72 -2 95 0.090 98 100 8.8 -0.1 409 81 97 108 105 160 410 81 65 84 69 70 -0.064 8.48 0.36

29 4.744 5.038 0.16 0.18 2.24 72 -1.99 1.78 72 -1.9 97 0.090 98 101 8.6 -0.2 436 82 100 113 108 168 424 81 65 84 69 70 -0.065 8.69 0.43

30 4.908 5.213 0.16 0.18 2.27 72 -1.95 1.78 72 -1.8 98 0.090 99 101 8.5 -0.1 451 84 104 117 111 173 433 82 65 84 69 70 -0.065 8.81 0.43

31 5.073 5.386 0.17 0.17 2.24 72 -2.25 1.77 72 -1.9 99 0.090 99 100 8.3 -0.2 467 86 107 121 114 179 435 82 65 84 69 70 -0.066 8.67 0.45

32 5.236 5.561 0.16 0.18 2.27 72 -1.9 1.79 72 -1.9 100 0.090 98 101 8.1 -0.2 487 87 111 126 118 186 442 82 65 84 69 70 -0.066 8.85 0.45

33 5.400 5.734 0.16 0.17 2.25 72 -1.92 1.74 72 -2.2 101 0.090 99 100 7.9 -0.2 501 89 114 130 121 191 441 83 65 84 69 70 -0.066 8.65 0.43

34 5.566 5.907 0.17 0.17 2.29 72 -2.43 1.70 72 -2.2 102 0.090 100 100 7.7 -0.2 514 91 118 135 125 197 450 83 65 84 69 70 -0.067 8.62 0.43

35 5.730 6.078 0.16 0.17 2.19 72 -2.2 1.63 72 -3.1 103 0.090 99 99 7.5 -0.2 529 93 122 139 128 202 456 83 65 84 69 71 -0.067 8.79 0.39

36 5.893 6.247 0.16 0.17 2.18 72 -3.24 1.45 72 -6.8 103 0.090 99 98 7.3 -0.2 541 95 126 142 132 207 456 83 65 84 69 71 -0.068 8.76 0.39

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 13 High Burn Run 3

58 of 190

ure:_________________ __________________

Page 59: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.26 ft/sec.2408 185 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 222.0 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.8 scfm29-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 14 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.18 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP 0.086 0.090 0.090 0.078 0.082 0.090 0.094 0.080 0.092 "H2O

OMNI Equipment Numbers: Temp: 70 70 70 70 70 70 70 70 70 °FVstrav 19.76 ft/sec Vscent 20.34 ft/sec Fp 0.971

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

37 6.057 6.412 0.16 0.17 1.95 73 -5.56 1.51 72 -11.7 103 0.090 99 95 7.2 -0.1 550 97 130 144 136 211 455 83 65 84 69 71 -0.066 8.9 0.39

38 6.207 6.563 0.15 0.15 2.34 73 -11.02 1.49 72 -11.6 104 0.090 91 87 7.1 -0.1 556 99 133 146 140 215 447 82 65 84 69 71 -0.066 8.41 0.42

39 6.362 6.732 0.16 0.17 1.79 73 -12.79 1.76 73 -1.4 103 0.090 94 97 6.9 -0.2 558 101 137 150 144 218 442 82 66 83 69 71 -0.066 8.18 0.38

40 6.505 6.905 0.14 0.17 1.82 73 -12.63 1.76 73 -1.4 104 0.090 86 100 6.8 -0.1 559 104 141 153 148 221 443 82 66 84 69 71 -0.067 8.11 0.31

41 6.670 7.079 0.17 0.17 2.28 73 -2.03 1.79 73 -1.7 104 0.090 100 100 6.7 -0.1 565 106 145 157 152 225 448 81 66 84 69 71 -0.066 8.39 0.22

42 6.834 7.253 0.16 0.17 2.23 73 -2.04 1.78 73 -1.5 104 0.090 99 100 6.5 -0.2 570 109 148 161 156 229 447 82 66 84 69 71 -0.066 8.12 0.22

43 6.998 7.427 0.16 0.17 2.25 73 -1.99 1.77 73 -1.5 104 0.090 99 100 6.3 -0.2 575 111 151 165 160 232 452 82 66 84 69 71 -0.067 8.07 0.23

44 7.162 7.601 0.16 0.17 2.26 73 -1.98 1.77 73 -1.5 105 0.090 99 100 6.2 -0.1 583 114 154 170 164 237 461 82 66 84 70 71 -0.067 8.73 0.23

45 7.326 7.774 0.16 0.17 2.25 73 -1.91 1.78 73 -1.5 105 0.090 99 100 6.1 -0.1 588 117 156 174 169 241 458 82 66 84 70 71 -0.066 8.55 0.21

46 7.490 7.949 0.16 0.18 2.25 73 -2.01 1.78 73 -1.5 106 0.090 99 101 5.9 -0.2 591 119 158 179 173 244 457 83 66 84 70 71 -0.066 8.28 0.21

47 7.654 8.123 0.16 0.17 2.25 73 -2.04 1.77 73 -1.7 106 0.090 99 101 5.8 -0.1 595 122 161 183 178 248 462 83 66 84 70 72 -0.067 8.57 0.17

48 7.819 8.297 0.17 0.17 2.26 73 -1.69 1.76 73 -1.6 107 0.090 100 101 5.6 -0.2 599 125 163 188 183 252 463 83 66 84 70 72 -0.067 8.79 0.15

49 7.983 8.470 0.16 0.17 2.23 73 -1.57 1.77 73 -1.5 107 0.090 99 100 5.5 -0.1 603 128 164 193 187 255 466 83 66 84 70 71 -0.067 8.75 0.15

50 8.146 8.644 0.16 0.17 2.24 73 -2.05 1.77 73 -1.8 108 0.090 99 101 5.3 -0.2 608 131 166 198 192 259 473 83 66 84 70 71 -0.068 9.06 0.14

51 8.310 8.818 0.16 0.17 2.25 73 -1.58 1.77 73 -1.5 108 0.090 99 101 5.1 -0.2 614 134 168 203 198 263 480 83 66 84 70 72 -0.068 9.49 0.11

52 8.474 8.991 0.16 0.17 2.32 73 -2.14 1.79 73 -1.8 108 0.090 99 100 5.0 -0.1 618 137 171 208 203 267 478 83 66 84 70 72 -0.068 9.11 0.1

53 8.642 9.167 0.17 0.18 2.33 74 -2.11 1.83 73 -1.8 109 0.090 102 102 4.9 -0.1 622 140 173 213 208 271 480 83 66 84 70 72 -0.068 9.54 0.11

54 8.809 9.343 0.17 0.18 2.35 74 -1.98 1.81 73 -1.6 109 0.090 101 102 4.7 -0.2 625 144 177 218 213 275 478 83 66 84 71 72 -0.067 9.01 0.11

55 8.977 9.519 0.17 0.18 2.34 74 -2.09 1.83 73 -1.6 109 0.090 102 102 4.6 -0.1 627 147 181 223 218 279 476 83 66 84 71 72 -0.068 8.79 0.13

56 9.145 9.696 0.17 0.18 2.35 74 -1.82 1.82 73 -1.6 108 0.090 102 102 4.5 -0.1 627 135 173 221 217 275 470 83 66 84 71 72 -0.067 8.83 0.12

57 9.312 9.872 0.17 0.18 2.35 74 -1.74 1.82 74 -1.8 107 0.090 101 102 4.3 -0.2 626 131 170 219 216 272 464 84 66 84 71 72 -0.066 9.23 0.12

58 9.479 10.048 0.17 0.18 2.35 74 -2.03 1.83 74 -1.7 107 0.090 101 102 4.2 -0.1 617 132 167 217 216 270 455 84 66 84 71 73 -0.065 8.68 0.15

59 9.647 10.224 0.17 0.18 2.33 74 -1.66 1.82 74 -1.9 106 0.090 101 102 4.1 -0.1 613 132 166 216 216 269 452 84 66 84 71 73 -0.065 8.41 0.17

60 9.814 10.400 0.17 0.18 2.33 74 -1.91 1.81 74 -1.6 107 0.090 101 102 4.0 -0.1 611 132 166 216 216 268 453 84 66 84 71 73 -0.065 8.96 0.14

61 9.981 10.576 0.17 0.18 2.34 74 -1.8 1.82 74 -1.9 107 0.090 101 102 3.9 -0.1 612 132 166 216 217 269 454 84 67 84 71 73 -0.065 9.35 0.11

62 10.148 10.752 0.17 0.18 2.29 74 -2.02 1.79 74 -1.9 107 0.090 101 102 3.7 -0.2 609 133 166 216 218 268 451 83 67 84 71 73 -0.064 9.2 0.13

63 10.314 10.927 0.17 0.17 2.27 74 -1.7 1.79 74 -1.9 107 0.090 100 101 3.5 -0.2 607 132 167 217 219 268 447 83 67 84 71 73 -0.063 8.97 0.16

64 10.478 11.101 0.16 0.17 2.24 74 -1.8 1.79 74 -1.9 107 0.090 99 100 3.4 -0.1 606 133 169 218 220 269 448 83 67 84 71 73 -0.064 8.85 0.18

65 10.643 11.276 0.17 0.17 2.27 74 -1.92 1.78 74 -1.9 107 0.090 100 101 3.3 -0.1 605 134 170 219 222 270 447 84 67 84 71 73 -0.064 9.2 0.14

66 10.808 11.451 0.16 0.18 2.27 74 -1.79 1.79 74 -1.7 107 0.090 100 101 3.2 -0.1 605 134 171 221 223 271 447 84 67 84 72 73 -0.063 9.16 0.13

67 10.974 11.625 0.17 0.17 2.27 74 -1.6 1.79 74 -1.6 106 0.090 100 100 3.1 -0.1 604 136 172 222 225 272 443 84 67 84 72 73 -0.064 8.68 0.15

68 11.138 11.800 0.16 0.18 2.25 75 -1.65 1.78 74 -1.6 106 0.090 99 101 3.0 -0.1 600 136 174 224 227 272 439 84 67 84 72 73 -0.063 8.25 0.2

69 11.303 11.974 0.17 0.17 2.25 75 -1.57 1.78 74 -1.8 106 0.090 99 100 2.9 -0.1 597 137 176 226 229 273 436 84 67 84 72 73 -0.062 8.33 0.21

70 11.467 12.148 0.16 0.17 2.27 75 -1.65 1.79 74 -1.6 105 0.090 99 100 2.8 -0.1 593 138 178 227 231 273 435 84 67 84 72 73 -0.063 8.34 0.18

71 11.632 12.323 0.16 0.18 2.26 75 -1.61 1.78 74 -1.9 105 0.090 99 101 2.7 -0.1 591 138 180 229 233 274 429 84 67 84 72 74 -0.063 8.14 0.21

72 11.797 12.497 0.17 0.17 2.25 75 -1.69 1.76 74 -1.6 104 0.090 99 100 2.6 -0.1 587 140 181 230 235 275 423 84 67 84 72 74 -0.062 7.71 0.33

73 11.961 12.671 0.16 0.17 2.25 75 -1.85 1.77 75 -1.6 104 0.090 99 100 2.6 0 581 141 183 232 237 275 416 84 67 84 72 74 -0.061 7.29 0.37

Control No. P-SSAR-0003 Page 6 of 13 High Burn Run 3

59 of 190

re:____________________ ____________________

Page 60: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.26 ft/sec.2408 185 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 222.0 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.8 scfm29-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 14 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.18 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP 0.086 0.090 0.090 0.078 0.082 0.090 0.094 0.080 0.092 "H2O

OMNI Equipment Numbers: Temp: 70 70 70 70 70 70 70 70 70 °FVstrav 19.76 ft/sec Vscent 20.34 ft/sec Fp 0.971

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

74 12.126 12.844 0.16 0.17 2.25 75 -1.65 1.78 75 -1.6 103 0.090 99 99 2.5 -0.1 574 141 185 233 239 274 405 84 67 84 72 74 -0.050 6.74 0.48

75 12.290 13.018 0.16 0.17 2.25 75 -1.88 1.76 75 -1.8 134 0.090 101 103 22.4 19.9 552 143 189 235 241 272 382 85 67 85 72 74 -0.063 3.91 0.26

76 12.454 13.192 0.16 0.17 2.24 75 -1.59 1.75 75 -1.9 136 0.090 101 103 22.0 -0.4 539 144 192 236 242 271 439 85 67 85 72 74 -0.071 2.52 0.36

77 12.620 13.366 0.17 0.17 2.31 75 -1.9 1.81 75 -1.9 123 0.090 102 102 21.8 -0.2 565 146 195 237 244 277 501 85 67 85 72 74 -0.071 7.12 0.44

78 12.787 13.542 0.17 0.18 2.31 75 -2.1 1.80 75 -1.7 120 0.090 102 103 21.6 -0.2 598 146 197 238 245 285 524 85 67 85 72 73 -0.072 11.84 0.58

79 12.953 13.717 0.17 0.18 2.31 75 -1.86 1.79 75 -1.8 120 0.090 101 102 21.3 -0.3 627 148 198 239 246 292 536 85 67 85 72 74 -0.072 11.23 0.76

80 13.119 13.892 0.17 0.17 2.30 75 -2.12 1.78 75 -1.7 121 0.090 101 102 21.1 -0.2 653 149 199 240 246 297 563 85 67 85 72 74 -0.073 12.11 0.44

81 13.285 14.067 0.17 0.18 2.29 75 -1.76 1.80 75 -1.7 124 0.090 102 102 20.8 -0.3 679 150 199 241 247 303 589 86 67 86 72 75 -0.076 13.2 0.42

82 13.451 14.242 0.17 0.18 2.30 75 -1.94 1.79 75 -1.9 125 0.090 102 102 20.4 -0.4 701 151 199 241 247 308 597 86 67 86 72 75 -0.075 14.92 0.46

83 13.618 14.416 0.17 0.17 2.30 75 -1.67 1.77 75 -2 127 0.090 103 102 20.1 -0.3 721 152 198 242 248 312 608 86 67 86 72 75 -0.077 14.16 0.44

84 13.783 14.590 0.16 0.17 2.27 75 -1.66 1.79 75 -1.7 129 0.090 101 102 19.9 -0.2 747 153 198 242 248 318 615 86 67 86 72 75 -0.078 15.29 0.42

85 13.948 14.765 0.17 0.18 2.29 75 -1.7 1.78 75 -1.9 130 0.090 102 103 19.6 -0.3 763 154 198 243 249 321 626 86 67 86 73 75 -0.080 15.66 0.42

86 14.114 14.939 0.17 0.17 2.28 75 -1.83 1.77 75 -2 132 0.090 102 102 19.2 -0.4 778 154 197 244 250 325 631 87 67 86 73 75 -0.079 16.57 0.86

87 14.280 15.113 0.17 0.17 2.28 75 -2.11 1.78 75 -1.7 133 0.090 102 103 18.8 -0.4 790 155 196 245 251 327 629 87 67 86 73 75 -0.079 17 0.83

88 14.445 15.287 0.17 0.17 2.29 75 -2.13 1.78 75 -1.8 133 0.090 102 103 18.3 -0.5 798 156 195 246 252 329 629 87 67 86 73 75 -0.079 16.8 0.71

89 14.610 15.461 0.16 0.17 2.27 75 -1.85 1.77 75 -1.7 133 0.090 102 103 18.1 -0.2 806 157 195 248 254 332 628 87 68 86 73 75 -0.079 16.73 0.64

90 14.775 15.635 0.17 0.17 2.28 75 -1.69 1.77 75 -2 133 0.090 102 103 17.8 -0.3 815 158 195 250 257 335 630 87 68 86 73 75 -0.079 16.58 0.57

91 14.941 15.808 0.17 0.17 2.29 75 -1.68 1.77 75 -1.9 134 0.090 103 102 17.7 -0.1 824 158 194 252 259 337 631 87 68 86 73 76 -0.079 16.38 0.55

92 15.107 15.982 0.17 0.17 2.28 76 -1.85 1.77 75 -1.7 135 0.090 102 103 17.4 -0.3 830 159 194 254 262 340 631 87 68 86 73 76 -0.078 16.47 0.59

93 15.272 16.155 0.17 0.17 2.26 76 -2.17 1.75 75 -1.7 135 0.090 102 102 16.9 -0.5 839 160 195 257 265 343 634 87 68 87 73 76 -0.079 16.95 0.66

94 15.437 16.328 0.16 0.17 2.28 76 -2.08 1.76 75 -1.8 135 0.090 102 102 16.8 -0.1 847 160 195 260 269 346 633 87 68 87 73 76 -0.078 17.21 0.68

95 15.602 16.501 0.17 0.17 2.28 76 -2.08 1.76 75 -1.8 136 0.090 102 102 16.5 -0.3 850 161 196 263 272 348 633 88 68 87 73 76 -0.079 16.9 0.55

96 15.768 16.674 0.17 0.17 2.28 76 -1.85 1.75 76 -2 136 0.090 103 102 16.2 -0.3 858 162 196 266 275 351 630 88 69 87 73 76 -0.078 16.79 0.52

97 15.933 16.846 0.16 0.17 2.26 76 -1.74 1.75 76 -1.9 135 0.090 102 101 15.9 -0.3 864 162 197 269 279 354 622 88 69 87 72 76 -0.077 16.41 0.45

98 16.098 17.019 0.16 0.17 2.28 76 -2.02 1.75 76 -1.7 135 0.090 102 102 15.6 -0.3 864 161 197 272 281 355 619 87 69 87 73 76 -0.076 16.09 0.36

99 16.263 17.192 0.17 0.17 2.29 76 -2.14 1.76 76 -1.7 134 0.080 108 108 15.3 -0.3 868 163 198 275 285 358 617 87 69 87 73 76 -0.075 15.8 0.31

100 16.430 17.365 0.17 0.17 2.27 76 -2.07 1.75 76 -1.8 134 0.090 103 102 15.0 -0.3 867 163 199 278 288 359 613 87 69 87 73 75 -0.076 15.56 0.27

101 16.595 17.538 0.16 0.17 2.28 76 -1.96 1.75 76 -2 134 0.090 102 102 14.8 -0.2 869 165 200 281 291 361 613 86 69 87 73 76 -0.075 15.56 0.27

102 16.760 17.710 0.17 0.17 2.29 76 -2.17 1.74 76 -1.7 134 0.080 108 107 14.6 -0.2 870 166 201 285 294 363 616 86 70 87 73 77 -0.075 15.62 0.27

103 16.926 17.884 0.17 0.17 2.28 76 -1.89 1.79 76 -1.8 135 0.080 109 109 14.3 -0.3 873 167 202 288 298 366 616 86 70 87 74 77 -0.075 15.72 0.26

104 17.093 18.058 0.17 0.17 2.28 76 -2.13 1.78 76 -2.1 134 0.090 103 102 14.0 -0.3 875 169 203 291 301 368 616 86 70 87 74 77 -0.076 15.84 0.32

105 17.258 18.232 0.16 0.17 2.27 76 -1.87 1.76 76 -2 135 0.080 108 109 13.7 -0.3 874 170 205 294 303 369 616 86 70 87 74 77 -0.075 15.78 0.3

106 17.422 18.408 0.16 0.18 2.28 76 -1.7 1.81 76 -2.1 134 0.080 107 110 13.5 -0.2 876 171 206 297 306 371 614 85 70 86 74 78 -0.075 15.79 0.29

107 17.588 18.583 0.17 0.17 2.28 76 -1.75 1.79 76 -2.3 134 0.090 102 103 13.2 -0.3 872 171 208 301 309 372 610 85 70 86 74 76 -0.073 15.7 0.25

108 17.754 18.757 0.17 0.17 2.26 76 -2.09 1.78 76 -2.2 134 0.080 109 109 13.0 -0.2 873 171 210 303 312 374 606 85 70 86 74 75 -0.074 15.58 0.27

109 17.919 18.932 0.16 0.17 2.27 77 -2.16 1.77 76 -2.3 133 0.090 101 103 12.7 -0.3 872 172 211 307 315 375 602 85 70 86 74 75 -0.074 15.47 0.24

110 18.084 19.104 0.16 0.17 2.28 77 -1.89 1.76 77 -2.1 132 0.090 101 101 12.5 -0.2 871 172 213 309 317 376 597 85 71 86 74 75 -0.074 15.35 0.22

Control No. P-SSAR-0003 Page 7 of 13 High Burn Run 3

60 of 190

re:______________________________

Page 61: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.26 ft/sec.2408 185 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 222.0 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.8 scfm29-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 14 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.18 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP 0.086 0.090 0.090 0.078 0.082 0.090 0.094 0.080 0.092 "H2O

OMNI Equipment Numbers: Temp: 70 70 70 70 70 70 70 70 70 °FVstrav 19.76 ft/sec Vscent 20.34 ft/sec Fp 0.971

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

111 18.249 19.279 0.16 0.18 2.27 77 -2.14 1.80 77 -2.5 132 0.090 101 103 12.3 -0.2 869 173 215 312 320 378 596 86 71 86 75 75 -0.072 15.27 0.21

112 18.415 19.454 0.17 0.18 2.28 77 -1.83 1.78 77 -2.4 132 0.090 102 103 12.0 -0.3 868 173 216 315 322 379 592 86 71 86 75 75 -0.071 15.06 0.19

113 18.580 19.629 0.16 0.18 2.27 77 -2.11 1.77 77 -2.5 131 0.090 101 103 11.8 -0.2 866 175 218 317 325 380 588 86 71 86 75 75 -0.072 14.96 0.18

114 18.745 19.802 0.17 0.17 2.27 77 -2.08 1.77 77 -2.4 131 0.090 101 101 11.5 -0.3 863 176 220 320 328 381 586 85 71 86 75 76 -0.072 14.82 0.16

115 18.910 19.976 0.16 0.17 2.28 77 -2.19 1.75 77 -2.4 130 0.090 101 102 11.4 -0.1 860 177 222 323 331 383 583 85 71 86 75 76 -0.072 14.7 0.15

116 19.076 20.148 0.17 0.17 2.28 77 -2.15 1.72 77 -2.6 130 0.090 102 101 11.1 -0.3 859 178 224 326 334 384 579 85 71 86 75 76 -0.072 14.55 0.16

117 19.241 20.321 0.16 0.17 2.28 77 -1.74 1.76 77 -2.8 129 0.090 101 101 10.9 -0.2 857 178 226 328 336 385 578 85 71 86 75 77 -0.071 14.37 0.15

118 19.406 20.494 0.16 0.17 2.26 77 -2.15 1.76 77 -2.8 129 0.090 101 101 10.7 -0.2 854 180 228 330 339 386 576 85 71 86 75 77 -0.071 14.19 0.15

119 19.571 20.668 0.17 0.17 2.28 77 -1.72 1.81 77 -2.9 128 0.080 107 108 10.4 -0.3 852 180 230 333 341 387 571 85 71 86 75 77 -0.070 13.95 0.15

120 19.737 20.843 0.17 0.18 2.28 77 -1.85 1.76 77 -3.1 127 0.090 102 102 10.3 -0.1 850 181 231 335 344 388 568 85 71 86 75 78 -0.070 13.76 0.15

121 19.902 21.015 0.17 0.17 2.28 77 -1.89 1.71 77 -3.1 127 0.090 101 100 10.1 -0.2 845 184 233 338 347 389 564 85 71 86 75 78 -0.069 13.57 0.16

122 20.067 21.185 0.16 0.17 2.27 78 -1.8 1.68 77 -3 127 0.090 101 99 9.9 -0.2 839 185 235 340 349 390 561 85 71 86 75 78 -0.069 13.32 0.16

123 20.232 21.353 0.16 0.17 2.27 78 -2.14 1.63 78 -3.1 126 0.090 101 98 9.7 -0.2 834 186 238 342 351 390 559 85 71 85 75 78 -0.069 13.13 0.18

124 20.397 21.518 0.16 0.16 2.27 78 -1.73 1.57 78 -3.5 126 0.090 101 96 9.5 -0.2 829 187 240 343 354 391 556 85 71 85 75 78 -0.068 13.08 0.19

125 20.562 21.680 0.17 0.16 2.24 78 -1.74 1.51 78 -3.6 125 0.090 101 94 9.3 -0.2 825 187 242 345 356 391 553 85 71 85 75 78 -0.068 12.96 0.2

126 20.726 21.839 0.16 0.16 2.26 78 -2.08 1.46 78 -3.6 125 0.080 106 98 9.1 -0.2 820 189 243 346 358 391 552 85 71 85 75 79 -0.067 12.87 0.18

127 20.891 21.995 0.16 0.16 2.26 78 -2 1.41 78 -3.4 125 0.090 101 91 9.0 -0.1 818 189 245 348 360 392 548 85 71 85 75 79 -0.067 12.74 0.18

128 21.057 22.149 0.17 0.15 2.27 78 -2.11 1.39 78 -3.5 125 0.090 101 90 8.8 -0.2 813 190 247 349 362 392 544 85 71 85 75 79 -0.068 12.47 0.16

129 21.221 22.301 0.16 0.15 2.24 78 -1.99 1.36 78 -3.6 124 0.090 100 88 8.6 -0.2 811 190 249 350 363 393 545 85 71 85 75 79 -0.067 12.47 0.17

130 21.385 22.452 0.16 0.15 2.25 78 -1.98 1.34 78 -3.6 124 0.090 100 88 8.4 -0.2 807 191 251 351 365 393 541 85 71 85 75 78 -0.067 12.41 0.17

131 21.550 22.604 0.16 0.15 2.25 78 -1.9 1.80 78 -4.8 124 0.090 100 88 8.2 -0.2 802 191 252 352 366 393 540 85 71 85 75 78 -0.066 12.29 0.17

132 21.715 22.777 0.16 0.17 2.26 78 -1.95 1.76 78 -5.2 123 0.090 100 101 8.1 -0.1 799 192 254 353 368 393 537 85 71 86 75 79 -0.066 12.23 0.18

133 21.879 22.951 0.16 0.17 2.24 78 -2.05 1.73 78 -5.2 123 0.090 100 101 7.9 -0.2 796 192 256 354 369 393 533 84 71 86 75 79 -0.066 12.17 0.17

134 22.043 23.124 0.16 0.17 2.25 78 -1.73 1.77 78 -5.4 123 0.090 100 101 7.7 -0.2 793 193 258 355 370 394 533 84 71 86 75 79 -0.066 12.09 0.19

135 22.208 23.298 0.16 0.17 2.26 78 -2.2 1.75 78 -5.6 122 0.090 100 101 7.6 -0.1 791 193 259 356 371 394 530 84 71 86 75 79 -0.065 12.01 0.17

136 22.373 23.471 0.17 0.17 2.24 78 -1.99 1.74 78 -5.4 122 0.090 100 100 7.4 -0.2 787 194 261 357 372 394 528 84 71 86 75 79 -0.065 11.97 0.18

137 22.536 23.644 0.16 0.17 2.24 78 -1.79 1.76 78 -5.5 121 0.090 99 100 7.3 -0.1 784 194 263 358 372 394 525 84 71 86 75 79 -0.065 11.89 0.16

138 22.701 23.818 0.16 0.17 2.24 78 -1.76 1.76 78 -5.5 121 0.090 100 101 7.1 -0.2 781 194 265 359 373 394 522 84 71 86 75 78 -0.064 11.73 0.16

139 22.865 23.991 0.16 0.17 2.24 78 -1.77 1.75 78 -5.7 121 0.090 100 100 7.0 -0.1 781 194 266 359 374 395 519 84 71 86 75 79 -0.064 11.64 0.17

140 23.029 24.165 0.16 0.17 2.23 78 -1.75 1.74 78 -5.7 120 0.090 100 101 6.7 -0.3 776 193 268 360 374 394 518 85 71 85 75 77 -0.063 11.51 0.17

141 23.193 24.338 0.16 0.17 2.27 78 -1.89 1.73 78 -5.5 120 0.090 100 100 6.6 -0.1 772 194 270 361 374 394 514 85 72 85 75 77 -0.063 11.35 0.22

142 23.358 24.513 0.16 0.18 2.27 78 -2.24 1.79 78 -5.9 119 0.090 100 101 6.5 -0.1 769 194 271 362 374 394 510 85 72 85 76 77 -0.064 11.26 0.22

143 23.523 24.688 0.16 0.17 2.25 78 -1.86 1.78 78 -5.9 119 0.090 100 101 6.4 -0.1 767 194 273 362 374 394 510 85 72 85 76 77 -0.063 11.24 0.21

144 23.688 24.863 0.16 0.18 2.24 78 -2.26 1.77 79 -5.7 119 0.090 100 101 6.3 -0.1 765 195 275 362 374 394 508 85 72 85 76 78 -0.063 11.26 0.21

145 23.852 25.037 0.16 0.17 2.25 78 -2.24 1.78 79 -5.9 119 0.090 99 101 6.1 -0.2 761 195 276 363 374 394 508 85 72 85 76 77 -0.063 11.15 0.21

146 24.017 25.211 0.16 0.17 2.23 78 -2.08 1.76 79 -5.7 119 0.090 100 101 6.0 -0.1 759 194 277 363 375 394 508 85 72 85 76 76 -0.063 11.04 0.21

147 24.181 25.385 0.16 0.17 2.22 79 -1.8 1.76 79 -5.8 119 0.090 99 101 5.8 -0.2 758 195 279 364 375 394 507 84 72 85 76 76 -0.062 10.93 0.2

Control No. P-SSAR-0003 Page 8 of 13 High Burn Run 3

61 of 190

ure:_____________ _______________________________________ ___________________________________________ __________________

Page 62: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.26 ft/sec.2408 185 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 222.0 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.8 scfm29-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 14 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.18 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP 0.086 0.090 0.090 0.078 0.082 0.090 0.094 0.080 0.092 "H2O

OMNI Equipment Numbers: Temp: 70 70 70 70 70 70 70 70 70 °FVstrav 19.76 ft/sec Vscent 20.34 ft/sec Fp 0.971

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

148 24.345 25.559 0.16 0.17 2.23 79 -1.8 1.78 79 -5.7 119 0.090 99 101 5.7 -0.1 755 195 280 364 375 394 504 84 72 86 76 76 -0.063 10.84 0.23

149 24.509 25.733 0.16 0.17 2.24 79 -2.09 1.77 79 -5.9 118 0.090 99 101 5.6 -0.1 754 196 282 364 374 394 500 84 72 86 76 77 -0.062 10.59 0.27

150 24.674 25.907 0.16 0.17 2.42 79 -2.2 1.75 79 -5.7 117 0.090 100 100 5.5 -0.1 750 195 283 364 374 393 497 84 72 86 76 77 -0.063 10.45 0.3

151 24.841 26.082 0.17 0.18 2.30 79 -2.29 1.75 79 -6 117 0.090 101 101 5.4 -0.1 748 195 285 363 374 393 494 84 72 86 76 78 -0.062 10.38 0.31

152 25.008 26.255 0.17 0.17 2.32 79 -2.08 1.77 79 -5.8 117 0.090 101 100 5.2 -0.2 745 195 286 363 375 393 492 84 72 86 76 78 -0.062 10.34 0.31

153 25.175 26.429 0.17 0.17 2.32 79 -2.34 1.76 79 -5.8 117 0.090 101 100 5.1 -0.1 743 196 287 363 374 393 491 84 72 86 76 78 -0.061 10.37 0.32

154 25.343 26.603 0.17 0.17 2.32 79 -2.05 1.75 79 -5.8 116 0.090 101 100 5.0 -0.1 740 196 288 362 374 392 489 85 72 86 76 78 -0.061 10.36 0.31

155 25.511 26.777 0.17 0.17 2.33 79 -2.14 1.75 79 -5.9 116 0.090 101 100 4.9 -0.1 738 196 290 362 374 392 487 85 72 86 76 78 -0.061 10.33 0.3

156 25.678 26.950 0.17 0.17 2.31 79 -1.91 1.76 79 -5.9 116 0.090 101 100 4.8 -0.1 736 195 291 361 374 391 485 85 72 86 76 76 -0.061 10.18 0.31

157 25.844 27.124 0.17 0.17 2.30 79 -2.39 1.75 79 -5.8 115 0.090 100 100 4.7 -0.1 734 195 292 361 374 391 484 85 72 86 76 76 -0.061 10.04 0.33

158 26.011 27.297 0.17 0.17 2.31 79 -2.4 1.74 79 -5.9 115 0.090 101 100 4.6 -0.1 730 195 292 360 373 390 484 85 72 86 76 76 -0.061 9.98 0.33

159 26.178 27.471 0.17 0.17 2.31 79 -2.18 1.79 79 -6.2 115 0.090 101 100 4.5 -0.1 728 195 293 359 373 390 481 85 72 86 76 77 -0.060 9.87 0.35

160 26.345 27.647 0.17 0.18 2.32 79 -1.96 1.80 79 -5.9 115 0.090 101 101 4.4 -0.1 726 195 293 359 372 389 478 85 72 86 76 77 -0.060 9.78 0.43

161 26.513 27.822 0.17 0.18 2.30 79 -1.96 1.78 79 -5.9 115 0.090 101 101 4.3 -0.1 725 195 294 358 372 389 476 85 72 85 76 77 -0.060 9.69 0.51

162 26.679 27.997 0.17 0.18 2.31 79 -1.98 1.79 79 -6 114 0.090 100 101 4.2 -0.1 723 194 295 357 371 388 476 85 72 85 76 77 -0.060 9.62 0.54

163 26.846 28.172 0.17 0.18 2.29 79 -1.92 1.76 80 -6.2 114 0.090 101 101 4.1 -0.1 719 195 296 356 371 387 475 85 72 85 76 77 -0.060 9.58 0.59

164 27.013 28.345 0.17 0.17 2.31 80 -2.36 1.74 79 -6 114 0.090 100 100 4.0 -0.1 718 194 296 356 371 387 475 84 72 85 76 77 -0.059 9.67 0.47

165 27.180 28.518 0.17 0.17 2.32 80 -1.92 1.73 80 -6.3 114 0.090 100 99 3.9 -0.1 717 195 297 355 370 387 474 84 72 85 76 78 -0.059 9.66 0.46

166 27.347 28.691 0.17 0.17 2.32 80 -1.98 1.82 80 -6.4 114 0.090 100 99 3.8 -0.1 712 195 297 354 370 386 472 84 72 86 76 78 -0.060 9.63 0.46

167 27.515 28.867 0.17 0.18 2.32 80 -2.34 1.78 80 -6.5 114 0.090 101 101 3.8 0 709 195 298 353 370 385 472 84 72 86 76 76 -0.059 9.65 0.49

168 27.682 29.041 0.17 0.17 2.31 80 -2.1 1.74 80 -6.6 113 0.090 100 100 3.7 -0.1 705 196 299 352 370 384 468 84 72 86 76 75 -0.059 9.64 0.47

169 27.849 29.215 0.17 0.17 2.30 80 -2.02 1.76 80 -6.9 113 0.090 100 100 3.5 -0.2 703 196 299 351 370 384 467 85 72 86 76 77 -0.059 9.59 0.46

170 28.016 29.387 0.17 0.17 2.31 80 -2.05 1.72 80 -7 113 0.090 100 99 3.5 0 697 196 299 350 370 382 468 85 72 86 76 77 -0.059 9.51 0.49

171 28.183 29.561 0.17 0.17 2.31 80 -2.04 1.75 80 -7.5 113 0.090 100 100 3.4 -0.1 694 197 300 349 370 382 463 85 72 86 76 77 -0.058 9.37 0.5

172 28.350 29.734 0.17 0.17 2.31 80 -2.23 1.73 80 -7.8 112 0.090 100 99 3.3 -0.1 690 197 300 349 370 381 461 85 72 86 76 77 -0.059 9.22 0.55

173 28.517 29.906 0.17 0.17 2.29 80 -2.15 1.68 80 -7.8 112 0.090 100 99 3.2 -0.1 687 197 300 348 370 380 460 85 72 86 76 77 -0.060 9.17 0.55

174 28.684 30.074 0.17 0.17 2.29 80 -2.18 1.60 80 -8.1 112 0.090 100 96 3.2 0 683 197 300 347 370 379 456 85 72 86 76 77 -0.060 9.08 0.55

175 28.851 30.244 0.17 0.17 2.30 80 -2.21 1.73 80 -9.4 111 0.090 100 97 3.1 -0.1 679 197 301 346 370 379 453 85 72 86 76 77 -0.061 8.98 0.57

176 29.018 30.413 0.17 0.17 2.30 80 -2.15 1.64 80 -9.5 112 0.090 100 97 3.0 -0.1 675 197 301 346 370 378 449 85 72 86 76 77 -0.060 8.9 0.6

177 29.184 30.586 0.17 0.17 2.29 80 -2.13 1.74 80 -11 111 0.090 100 99 2.9 -0.1 671 197 302 345 370 377 446 85 72 86 76 77 -0.060 8.84 0.6

178 29.352 30.756 0.17 0.17 2.28 80 -2.22 1.61 80 -11.5 111 0.090 101 97 2.8 -0.1 666 198 302 344 370 376 444 85 72 85 76 77 -0.060 8.83 0.6

179 29.518 30.917 0.17 0.16 2.29 80 -2.27 1.46 80 -11.9 111 0.090 100 92 2.8 0 664 197 302 343 370 375 441 85 72 85 76 77 -0.059 8.72 0.66

180 29.684 31.073 0.17 0.16 2.27 80 -2.07 1.74 80 -11.1 110 0.090 100 89 2.7 -0.1 660 198 303 342 370 375 437 84 72 85 76 77 -0.060 8.68 0.66

181 29.850 31.247 0.17 0.17 2.28 80 -1.98 1.74 80 -1.8 110 0.090 100 100 2.6 -0.1 655 197 303 341 370 373 435 84 72 85 77 77 -0.059 8.63 0.68

182 30.017 31.421 0.17 0.17 2.29 80 -2.34 1.78 80 -1.8 110 0.090 100 100 2.6 0 655 198 303 340 370 373 434 84 72 86 76 77 -0.059 8.59 0.67

183 30.183 31.596 0.17 0.18 2.29 80 -1.95 1.77 80 -1.7 110 0.090 100 100 2.5 -0.1 659 199 304 340 370 374 435 84 72 86 76 77 -0.059 8.95 0.5

184 30.349 31.771 0.17 0.18 2.28 80 -1.99 1.78 80 -1.7 110 0.090 100 100 2.4 -0.1 659 199 304 339 370 374 436 84 72 87 76 78 -0.059 8.86 0.48

Control No. P-SSAR-0003 Page 9 of 13 High Burn Run 3

62 of 190

ure:::___________________ ________________________

Page 63: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.26 ft/sec.2408 185 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 222.0 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.8 scfm29-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ 14 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.18 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP 0.086 0.090 0.090 0.078 0.082 0.090 0.094 0.080 0.092 "H2O

OMNI Equipment Numbers: Temp: 70 70 70 70 70 70 70 70 70 °FVstrav 19.76 ft/sec Vscent 20.34 ft/sec Fp 0.971

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

185 30.514 31.945 0.16 0.17 2.28 80 -2.04 1.78 80 -1.5 109 0.090 99 100 2.4 0 661 200 305 339 370 375 437 85 72 87 76 78 -0.060 8.72 0.5Avg/Tot 30.514 31.945 0.16 0.17 2.27 76 1.75 76 112 0.090 100 100 306.0 69 85 73 74 -0.063

Control No. P-SSAR-0003 Page 10 of 13 High Burn Run 3

63 of 190

re:___________________ _________________

Page 64: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis Industries Equipment Numbers: Model: Medium Flush Wood

Tracking No.: 2408Project No.: 0028WN123E

Run #: 3Date: 4/29/20

TRAIN 1 (First Hour emissions)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg B. Front filter catch Filter T237S 100.7 98.6 2.1 C. Rear filter catch Filter 0.0 D. Probe catch* Probe 0.0 E. Filter seals catch* Seals 0.0

Sub-Total Total Particulate, mg: 2.1

TRAIN 1 (Post First Hour Change-out)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg B. Front filter catch Filter T229AP 200.3 195.5 4.8 C. Rear filter catch Filter T239S 101.0 100.3 0.7 D. Probe catch* Probe 16 114267.5 114266.0 1.5 E. Filter seals catch* Seals R966 3372.5 3372.1 0.4

Sub-Total Total Particulate, mg: 7.4

Train 1 Aggregate Total Particulate, mg: 10.3

TRAIN 2Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg A. Front filter catch Filter T229BP 201.6 199.2 2.4 B. Rear filter catch Filter T238S, T241S 202.7 197.6 5.1 C. Probe catch* Probe 17 114563.2 114562.1 1.1 D. Filter seals catch* Seals R967 3543.9 3543.3 0.6

Total Particulate, mg: 9.2

AMBIENTSample Component Reagent Filter # or Weights

Probe # Final, mg Tare, mg Particulate, mg A. Front filter catch* Filter 0.0

Total Particulate, mg: 0.0

Component Equations: A. Front filter catch Final (mg) - Tare (mg) = Particulate, mg B. Rear filter catch Final (mg) - Tare (mg) = Particulate, mg C. Probe catch Final (mg) - Tare (mg) = Particulate, mg

Technician Signature:_____________________________________________________

*Particulate catch that results in a negative number, is assumed to be zero for probes and seals, negative numbers for filters are assumed to be part of the seal weight.

Wood Heater Lab Data - ASTM E3053 / ASTM E2515

Control No. P-SSAR-0003 High Burn Run 364 of 190

__________________________

Page 65: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN123ETracking No.: 2408

Run: 3Test Date:

Burn Rate 3.41 kg/hr dry

Average Tunnel Temperature 112 degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs 20.26 feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd 12707.4 dscf/hour

Average Delta p 0.090 inches H20Total Time of Test 185 minutes

Total Sample Volume - Vm 0.000 cubic feet 30.514 cubic feet 31.945 cubic feet 9.814 cubic feetAverage Gas Meter Temperature 74 degrees Fahrenheit 76 degrees Fahrenheit 76 degrees Fahrenheit 72 degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd 0.000 dscf 29.301 dscf 30.547 dscf 9.481 dscf

Total Particulates - mn 0 mg 10.3 mg 9.2 mg 2.1 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf 0.00035 grams/dscf 0.00030 grams/dscf 0.00022 grams/dscfTotal Particulate Emissions - ET 0.00 grams 13.77 grams 11.80 grams 2.81 gramsParticulate Emission Rate 0.00 grams/hour 4.47 grams/hour 3.83 grams/hour 2.81 grams/hourEmissions Factor 1.31 g/kg 1.12 g/kg 1.04 g/kg

Difference from Average Total Particulate Emissions 0.99 grams 0.99 grams

Complete Test RunTotal Particulate Emissions - ET 12.79 gramsParticulate Emission Rate 4.15 grams/hourEmissions Factor 1.22 grams/kg

First Hour EmissionsTotal Particulate Emissions - ET 2.81 gramsParticulate Emission Rate 2.81 grams/hourEmissions Factor 1.04 grams/kg

7.5% of Average Total Particulate Emissions 0.96 grams

Technician Signature:_____________________________________________________

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/29/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

Dual Train Comparison Results Are Acceptable

Filter Temps < 90 °F OKOKOKOK

Stove Surface ∆T NOT ACCEPTABLE

OK

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.OKPro-Rate Variation OK

Control No. P-SSAR-0003 High Burn Run 365 of 190

:_______________________________

Page 66: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 3

High Burn 1-minute data

Efficiency and Heat Output Results Kindling and start-up fuel removed from calculations

66 of 190

Page 67: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 110 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: #DIV/0! scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm29-Apr-20 Dilution Tunnel Static: "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.30 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP "H2O

OMNI Equipment Numbers: Temp: °FVstrav ft/sec Vscent ft/sec Fp

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

0 0.000 19.9 552 143 189 235 241 272 382 85 67 85 72 74 -0.063 3.91 0.26

1 0.000 0.00 #DIV/0! 19.6 -0.3 539 144 192 236 242 271 439 85 67 85 72 74 -0.071 2.52 0.36

2 0.000 0.00 #DIV/0! 19.4 -0.2 565 146 195 237 244 277 501 85 67 85 72 74 -0.071 7.12 0.44

3 0.000 0.00 #DIV/0! 19.2 -0.2 598 146 197 238 245 285 524 85 67 85 72 73 -0.072 11.84 0.58

4 0.000 0.00 #DIV/0! 18.9 -0.3 627 148 198 239 246 292 536 85 67 85 72 74 -0.072 11.23 0.76

5 0.000 0.00 #DIV/0! 18.7 -0.2 653 149 199 240 246 297 563 85 67 85 72 74 -0.073 12.11 0.44

6 0.000 0.00 #DIV/0! 18.4 -0.3 679 150 199 241 247 303 589 86 67 86 72 75 -0.076 13.2 0.42

7 0.000 0.00 #DIV/0! 18.0 -0.4 701 151 199 241 247 308 597 86 67 86 72 75 -0.075 14.92 0.46

8 0.000 0.00 #DIV/0! 17.7 -0.3 721 152 198 242 248 312 608 86 67 86 72 75 -0.077 14.16 0.44

9 0.000 0.00 #DIV/0! 17.5 -0.2 747 153 198 242 248 318 615 86 67 86 72 75 -0.078 15.29 0.42

10 0.000 0.00 #DIV/0! 17.2 -0.3 763 154 198 243 249 321 626 86 67 86 73 75 -0.080 15.66 0.42

11 0.000 0.00 #DIV/0! 16.8 -0.4 778 154 197 244 250 325 631 87 67 86 73 75 -0.079 16.57 0.86

12 0.000 0.00 #DIV/0! 16.4 -0.4 790 155 196 245 251 327 629 87 67 86 73 75 -0.079 17 0.83

13 0.000 0.00 #DIV/0! 15.9 -0.5 798 156 195 246 252 329 629 87 67 86 73 75 -0.079 16.8 0.71

14 0.000 0.00 #DIV/0! 15.7 -0.2 806 157 195 248 254 332 628 87 68 86 73 75 -0.079 16.73 0.64

15 0.000 0.00 #DIV/0! 15.4 -0.3 815 158 195 250 257 335 630 87 68 86 73 75 -0.079 16.58 0.57

16 0.000 0.00 #DIV/0! 15.3 -0.1 824 158 194 252 259 337 631 87 68 86 73 76 -0.079 16.38 0.55

17 0.000 0.00 #DIV/0! 15.0 -0.3 830 159 194 254 262 340 631 87 68 86 73 76 -0.078 16.47 0.59

18 0.000 0.00 #DIV/0! 14.5 -0.5 839 160 195 257 265 343 634 87 68 87 73 76 -0.079 16.95 0.66

19 0.000 0.00 #DIV/0! 14.4 -0.1 847 160 195 260 269 346 633 87 68 87 73 76 -0.078 17.21 0.68

20 0.000 0.00 #DIV/0! 14.1 -0.3 850 161 196 263 272 348 633 88 68 87 73 76 -0.079 16.9 0.55

21 0.000 0.00 #DIV/0! 13.8 -0.3 858 162 196 266 275 351 630 88 69 87 73 76 -0.078 16.79 0.52

22 0.000 0.00 #DIV/0! 13.5 -0.3 864 162 197 269 279 354 622 88 69 87 72 76 -0.077 16.41 0.45

23 0.000 0.00 #DIV/0! 13.2 -0.3 864 161 197 272 281 355 619 87 69 87 73 76 -0.076 16.09 0.36

24 0.000 0.00 #DIV/0! 12.9 -0.3 868 163 198 275 285 358 617 87 69 87 73 76 -0.075 15.8 0.31

25 0.000 0.00 #DIV/0! 12.6 -0.3 867 163 199 278 288 359 613 87 69 87 73 75 -0.076 15.56 0.27

26 0.000 0.00 #DIV/0! 12.4 -0.2 869 165 200 281 291 361 613 86 69 87 73 76 -0.075 15.56 0.27

27 0.000 0.00 #DIV/0! 12.2 -0.2 870 166 201 285 294 363 616 86 70 87 73 77 -0.075 15.62 0.27

28 0.000 0.00 #DIV/0! 11.9 -0.3 873 167 202 288 298 366 616 86 70 87 74 77 -0.075 15.72 0.26

29 0.000 0.00 #DIV/0! 11.6 -0.3 875 169 203 291 301 368 616 86 70 87 74 77 -0.076 15.84 0.32

30 0.000 0.00 #DIV/0! 11.3 -0.3 874 170 205 294 303 369 616 86 70 87 74 77 -0.075 15.78 0.3

31 0.000 0.00 #DIV/0! 11.1 -0.2 876 171 206 297 306 371 614 85 70 86 74 78 -0.075 15.79 0.29

32 0.000 0.00 #DIV/0! 10.8 -0.3 872 171 208 301 309 372 610 85 70 86 74 76 -0.073 15.7 0.25

33 0.000 0.00 #DIV/0! 10.6 -0.2 873 171 210 303 312 374 606 85 70 86 74 75 -0.074 15.58 0.27

34 0.000 0.00 #DIV/0! 10.3 -0.3 872 172 211 307 315 375 602 85 70 86 74 75 -0.074 15.47 0.24

35 0.000 0.00 #DIV/0! 10.1 -0.2 871 172 213 309 317 376 597 85 71 86 74 75 -0.074 15.35 0.22

36 0.000 0.00 #DIV/0! 9.9 -0.2 869 173 215 312 320 378 596 86 71 86 75 75 -0.072 15.27 0.21

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 11 High Burn Run 3_Efficiency

67 of 190

re:____________ __________________________________________________________________________________________ ______________

Page 68: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 110 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: #DIV/0! scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm29-Apr-20 Dilution Tunnel Static: "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.30 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP "H2O

OMNI Equipment Numbers: Temp: °FVstrav ft/sec Vscent ft/sec Fp

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

37 0.000 0.00 #DIV/0! 9.6 -0.3 868 173 216 315 322 379 592 86 71 86 75 75 -0.071 15.06 0.19

38 0.000 0.00 #DIV/0! 9.4 -0.2 866 175 218 317 325 380 588 86 71 86 75 75 -0.072 14.96 0.18

39 0.000 0.00 #DIV/0! 9.1 -0.3 863 176 220 320 328 381 586 85 71 86 75 76 -0.072 14.82 0.16

40 0.000 0.00 #DIV/0! 9.0 -0.1 860 177 222 323 331 383 583 85 71 86 75 76 -0.072 14.7 0.15

41 0.000 0.00 #DIV/0! 8.7 -0.3 859 178 224 326 334 384 579 85 71 86 75 76 -0.072 14.55 0.16

42 0.000 0.00 #DIV/0! 8.5 -0.2 857 178 226 328 336 385 578 85 71 86 75 77 -0.071 14.37 0.15

43 0.000 0.00 #DIV/0! 8.3 -0.2 854 180 228 330 339 386 576 85 71 86 75 77 -0.071 14.19 0.15

44 0.000 0.00 #DIV/0! 8.0 -0.3 852 180 230 333 341 387 571 85 71 86 75 77 -0.070 13.95 0.15

45 0.000 0.00 #DIV/0! 7.9 -0.1 850 181 231 335 344 388 568 85 71 86 75 78 -0.070 13.76 0.15

46 0.000 0.00 #DIV/0! 7.7 -0.2 845 184 233 338 347 389 564 85 71 86 75 78 -0.069 13.57 0.16

47 0.000 0.00 #DIV/0! 7.5 -0.2 839 185 235 340 349 390 561 85 71 86 75 78 -0.069 13.32 0.16

48 0.000 0.00 #DIV/0! 7.3 -0.2 834 186 238 342 351 390 559 85 71 85 75 78 -0.069 13.13 0.18

49 0.000 0.00 #DIV/0! 7.1 -0.2 829 187 240 343 354 391 556 85 71 85 75 78 -0.068 13.08 0.19

50 0.000 0.00 #DIV/0! 6.9 -0.2 825 187 242 345 356 391 553 85 71 85 75 78 -0.068 12.96 0.2

51 0.000 0.00 #DIV/0! 6.7 -0.2 820 189 243 346 358 391 552 85 71 85 75 79 -0.067 12.87 0.18

52 0.000 0.00 #DIV/0! 6.6 -0.1 818 189 245 348 360 392 548 85 71 85 75 79 -0.067 12.74 0.18

53 0.000 0.00 #DIV/0! 6.4 -0.2 813 190 247 349 362 392 544 85 71 85 75 79 -0.068 12.47 0.16

54 0.000 0.00 #DIV/0! 6.2 -0.2 811 190 249 350 363 393 545 85 71 85 75 79 -0.067 12.47 0.17

55 0.000 0.00 #DIV/0! 6.0 -0.2 807 191 251 351 365 393 541 85 71 85 75 78 -0.067 12.41 0.17

56 0.000 0.00 #DIV/0! 5.8 -0.2 802 191 252 352 366 393 540 85 71 85 75 78 -0.066 12.29 0.17

57 0.000 0.00 #DIV/0! 5.7 -0.1 799 192 254 353 368 393 537 85 71 86 75 79 -0.066 12.23 0.18

58 0.000 0.00 #DIV/0! 5.5 -0.2 796 192 256 354 369 393 533 84 71 86 75 79 -0.066 12.17 0.17

59 0.000 0.00 #DIV/0! 5.3 -0.2 793 193 258 355 370 394 533 84 71 86 75 79 -0.066 12.09 0.19

60 0.000 0.00 #DIV/0! 5.2 -0.1 791 193 259 356 371 394 530 84 71 86 75 79 -0.065 12.01 0.17

61 0.000 0.00 #DIV/0! 5.0 -0.2 787 194 261 357 372 394 528 84 71 86 75 79 -0.065 11.97 0.18

62 0.000 0.00 #DIV/0! 4.9 -0.1 784 194 263 358 372 394 525 84 71 86 75 79 -0.065 11.89 0.16

63 0.000 0.00 #DIV/0! 4.7 -0.2 781 194 265 359 373 394 522 84 71 86 75 78 -0.064 11.73 0.16

64 0.000 0.00 #DIV/0! 4.6 -0.1 781 194 266 359 374 395 519 84 71 86 75 79 -0.064 11.64 0.17

65 0.000 0.00 #DIV/0! 4.3 -0.3 776 193 268 360 374 394 518 85 71 85 75 77 -0.063 11.51 0.17

66 0.000 0.00 #DIV/0! 4.2 -0.1 772 194 270 361 374 394 514 85 72 85 75 77 -0.063 11.35 0.22

67 0.000 0.00 #DIV/0! 4.1 -0.1 769 194 271 362 374 394 510 85 72 85 76 77 -0.064 11.26 0.22

68 0.000 0.00 #DIV/0! 4.0 -0.1 767 194 273 362 374 394 510 85 72 85 76 77 -0.063 11.24 0.21

69 0.000 0.00 #DIV/0! 3.9 -0.1 765 195 275 362 374 394 508 85 72 85 76 78 -0.063 11.26 0.21

70 0.000 0.00 #DIV/0! 3.7 -0.2 761 195 276 363 374 394 508 85 72 85 76 77 -0.063 11.15 0.21

71 0.000 0.00 #DIV/0! 3.6 -0.1 759 194 277 363 375 394 508 85 72 85 76 76 -0.063 11.04 0.21

72 0.000 0.00 #DIV/0! 3.4 -0.2 758 195 279 364 375 394 507 84 72 85 76 76 -0.062 10.93 0.2

73 0.000 0.00 #DIV/0! 3.3 -0.1 755 195 280 364 375 394 504 84 72 86 76 76 -0.063 10.84 0.23

Control No. P-SSAR-0003 Page 6 of 11 High Burn Run 3_Efficiency

68 of 190

re:____________________________________________

Page 69: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 110 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: #DIV/0! scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm29-Apr-20 Dilution Tunnel Static: "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.30 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP "H2O

OMNI Equipment Numbers: Temp: °FVstrav ft/sec Vscent ft/sec Fp

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

74 0.000 0.00 #DIV/0! 3.2 -0.1 754 196 282 364 374 394 500 84 72 86 76 77 -0.062 10.59 0.27

75 0.000 0.00 #DIV/0! 3.1 -0.1 750 195 283 364 374 393 497 84 72 86 76 77 -0.063 10.45 0.3

76 0.000 0.00 #DIV/0! 3.0 -0.1 748 195 285 363 374 393 494 84 72 86 76 78 -0.062 10.38 0.31

77 0.000 0.00 #DIV/0! 2.8 -0.2 745 195 286 363 375 393 492 84 72 86 76 78 -0.062 10.34 0.31

78 0.000 0.00 #DIV/0! 2.7 -0.1 743 196 287 363 374 393 491 84 72 86 76 78 -0.061 10.37 0.32

79 0.000 0.00 #DIV/0! 2.6 -0.1 740 196 288 362 374 392 489 85 72 86 76 78 -0.061 10.36 0.31

80 0.000 0.00 #DIV/0! 2.5 -0.1 738 196 290 362 374 392 487 85 72 86 76 78 -0.061 10.33 0.3

81 0.000 0.00 #DIV/0! 2.4 -0.1 736 195 291 361 374 391 485 85 72 86 76 76 -0.061 10.18 0.31

82 0.000 0.00 #DIV/0! 2.3 -0.1 734 195 292 361 374 391 484 85 72 86 76 76 -0.061 10.04 0.33

83 0.000 0.00 #DIV/0! 2.2 -0.1 730 195 292 360 373 390 484 85 72 86 76 76 -0.061 9.98 0.33

84 0.000 0.00 #DIV/0! 2.1 -0.1 728 195 293 359 373 390 481 85 72 86 76 77 -0.060 9.87 0.35

85 0.000 0.00 #DIV/0! 2.0 -0.1 726 195 293 359 372 389 478 85 72 86 76 77 -0.060 9.78 0.43

86 0.000 0.00 #DIV/0! 1.9 -0.1 725 195 294 358 372 389 476 85 72 85 76 77 -0.060 9.69 0.51

87 0.000 0.00 #DIV/0! 1.8 -0.1 723 194 295 357 371 388 476 85 72 85 76 77 -0.060 9.62 0.54

88 0.000 0.00 #DIV/0! 1.7 -0.1 719 195 296 356 371 387 475 85 72 85 76 77 -0.060 9.58 0.59

89 0.000 0.00 #DIV/0! 1.6 -0.1 718 194 296 356 371 387 475 84 72 85 76 77 -0.059 9.67 0.47

90 0.000 0.00 #DIV/0! 1.5 -0.1 717 195 297 355 370 387 474 84 72 85 76 78 -0.059 9.66 0.46

91 0.000 0.00 #DIV/0! 1.4 -0.1 712 195 297 354 370 386 472 84 72 86 76 78 -0.060 9.63 0.46

92 0.000 0.00 #DIV/0! 1.4 0 709 195 298 353 370 385 472 84 72 86 76 76 -0.059 9.65 0.49

93 0.000 0.00 #DIV/0! 1.3 -0.1 705 196 299 352 370 384 468 84 72 86 76 75 -0.059 9.64 0.47

94 0.000 0.00 #DIV/0! 1.1 -0.2 703 196 299 351 370 384 467 85 72 86 76 77 -0.059 9.59 0.46

95 0.000 0.00 #DIV/0! 1.1 0 697 196 299 350 370 382 468 85 72 86 76 77 -0.059 9.51 0.49

96 0.000 0.00 #DIV/0! 1.0 -0.1 694 197 300 349 370 382 463 85 72 86 76 77 -0.058 9.37 0.5

97 0.000 0.00 #DIV/0! 0.9 -0.1 690 197 300 349 370 381 461 85 72 86 76 77 -0.059 9.22 0.55

98 0.000 0.00 #DIV/0! 0.8 -0.1 687 197 300 348 370 380 460 85 72 86 76 77 -0.060 9.17 0.55

99 0.000 0.00 #DIV/0! 0.8 0 683 197 300 347 370 379 456 85 72 86 76 77 -0.060 9.08 0.55

100 0.000 0.00 #DIV/0! 0.7 -0.1 679 197 301 346 370 379 453 85 72 86 76 77 -0.061 8.98 0.57

101 0.000 0.00 #DIV/0! 0.6 -0.1 675 197 301 346 370 378 449 85 72 86 76 77 -0.060 8.9 0.6

102 0.000 0.00 #DIV/0! 0.5 -0.1 671 197 302 345 370 377 446 85 72 86 76 77 -0.060 8.84 0.6

103 0.000 0.00 #DIV/0! 0.4 -0.1 666 198 302 344 370 376 444 85 72 85 76 77 -0.060 8.83 0.6

104 0.000 0.00 #DIV/0! 0.4 0 664 197 302 343 370 375 441 85 72 85 76 77 -0.059 8.72 0.66

105 0.000 0.00 #DIV/0! 0.3 -0.1 660 198 303 342 370 375 437 84 72 85 76 77 -0.060 8.68 0.66

106 0.000 0.00 #DIV/0! 0.2 -0.1 655 197 303 341 370 373 435 84 72 85 77 77 -0.059 8.63 0.68

107 0.000 0.00 #DIV/0! 0.2 0 655 198 303 340 370 373 434 84 72 86 76 77 -0.059 8.59 0.67

108 0.000 0.00 #DIV/0! 0.1 -0.1 659 199 304 340 370 374 435 84 72 86 76 77 -0.059 8.95 0.5

109 0.000 0.00 #DIV/0! 0.0 -0.1 659 199 304 339 370 374 436 84 72 87 76 78 -0.059 8.86 0.48

110 0.000 0.00 #DIV/0! 0.0 0 661 200 305 339 370 375 437 85 72 87 76 78 -0.060 8.72 0.5

Control No. P-SSAR-0003 Page 7 of 11 High Burn Run 3_Efficiency

69 of 190

e:_________________ ________________

Page 70: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 3Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 110 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: #DIV/0! scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm29-Apr-20 Dilution Tunnel Static: "H2O Post-Test Leak Check (1): 0.000 cfm @ 1 in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.30 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.35 29.35 "Hg Initial dP "H2O

OMNI Equipment Numbers: Temp: °FVstrav ft/sec Vscent ft/sec Fp

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Avg/Tot 0.000 0.000 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! 103.0 71 86 75 77 -0.067

Control No. P-SSAR-0003 Page 8 of 11 High Burn Run 3_Efficiency

70 of 190

:__________________________________

Page 71: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN123ETracking No.: 2408

Run: 3Test Date:

Burn Rate 4.02 kg/hr dry

Average Tunnel Temperature #DIV/0! degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs #DIV/0! feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd #DIV/0! dscf/hour

Average Delta p #DIV/0! inches H20Total Time of Test 110 minutes

Total Sample Volume - Vm 0.000 cubic feet 0.000 cubic feet 0.000 cubic feet 0.000 cubic feetAverage Gas Meter Temperature 77 degrees Fahrenheit #DIV/0! degrees Fahrenheit #DIV/0! degrees Fahrenheit #DIV/0! degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd 0.000 dscf #DIV/0! dscf #DIV/0! dscf #DIV/0! dscf

Total Particulates - mn 0 mg 12.2 mg 13.2 mg 3.6 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf #DIV/0! grams/dscf #DIV/0! grams/dscf #DIV/0! grams/dscfTotal Particulate Emissions - ET #DIV/0! grams #DIV/0! grams #DIV/0! grams #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hour #DIV/0! grams/hour #DIV/0! grams/hour #DIV/0! grams/hourEmissions Factor #DIV/0! g/kg #DIV/0! g/kg #DIV/0! g/kg

Difference from Average Total Particulate Emissions #DIV/0! grams #DIV/0! grams

Complete Test RunTotal Particulate Emissions - ET #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hourEmissions Factor #DIV/0! grams/kg

First Hour EmissionsTotal Particulate Emissions - ET #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hourEmissions Factor #DIV/0! grams/kg

7.5% of Average Total Particulate Emissions #DIV/0! grams

Technician Signature:_____________________________________________________

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/29/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

#DIV/0!

Filter Temps < 90 °F OKOKOK

#DIV/0!

Stove Surface ∆T OK

OK

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.#DIV/0!Pro-Rate Variation

OK

Control No. P-SSAR-0003 High Burn Run 3_Efficiency71 of 190

____________________________________________________________ ____________________________________________________________________________________________ _______________________________________________________________________ ___________________

Page 72: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Manufacturer: Travis Industries Technician Signature:Model:edium Flush Wood

Date: 04/29/20Run: 3

Control #: 0028WN123E Test Duration: 110

Output Category: IV

HHV Basis LHV BasisOverall Efficiency 72.0% 77.8%

Combustion Efficiency 97.6% 97.6%Heat Transfer Efficiency 74% 79.7%

Output Rate (kJ/h) 58,396 55,395 (Btu/h)Burn Rate (kg/h) 4.09 9.02 (lb/h)

Input (kJ/h) 81,100 76,932 (Btu/h)

Test Load Weight (dry kg) 7.51 16.54 dry lbMC wet (%) 16.87448047MC dry (%) 20.30

Particulate (g ) #DIV/0!CO (g) 257

Test Duration (h) 1.83

Emissions Particulate COg/MJ Output #DIV/0! 2.40

g/kg Dry Fuel #DIV/0! 34.21g/h #DIV/0! 140.04

lb/MM Btu Output #DIV/0! 5.57

Air/Fuel Ratio (A/F) 8.71

VERSION: 2.2 12/14/2009

Test Results in Accordance with CSA B415.1-09

Wood Heater Efficiency Results - CSA B415.1

72 of 190

:

Page 73: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 VersionCordwood Fuel Load Calculators 10 lb/ft3 Nominal Load DensityCore 45 65% of Total Load Weight, Remainder 35 55% of Total Load Weight

Values to be input manuallyFor All Usable Firebox Volumes High Fire Test OnlyNominal Required Load Density (wet basis) 10 lb/ft3

Usable Firebox Volume 2.20 ft3

Total Nom. Load Wt. Target 22.00 lbTotal Load Wt. Allowable Range 20.90 to 23.10 lbCore Target Wt. Allowable Range 9.90 to 14.30 lbRemainder Load Wt. Allowable Range 7.70 to 12.10 lb

Mid PointCore Load Pc. Wt. Allowable Range 3.30 to 5.50 lb 4.40Remainder Load Pc. Wt. Allowable Range 2.20 to 12.10 lb 7.15 Fuel Piece Moisture Reading (% dry basis)

Pc. # 1 2 3 Ave.Core Load Piece Wt. Actual 1 3.61 lb In Range 18.6 18.3 19 18.6 In Range 3.04 lb 1.38 kg

2 4.15 lb In Range 24.4 22.5 24.4 23.8 In Range 3.35 lb 1.52 kg3 4.29 lb In Range 23.8 23.8 22 23.2 In Range 3.48 lb 1.58 kg

Core Load Total. Wt. Actual 12.05 lb In RangePc. #

Remainder Load Piece Wt. 1 4.84 lb In Range 25.8 25 23.8 24.9 In Range 3.88 lb 1.76 kg(1 to 3 Pcs.) 2 2.77 lb In Range 19.5 21 17.7 19.4 In Range 2.32 lb 1.05 kg

3 2.42 lb In Range 18.6 19 18.7 18.8 In Range 2.04 lb 0.92 kgRemainder Load Tot. Wt. Act 10.03 lb In Range Total Load Ave. MC (% dry basis) 21.9 In RangeTotal Load Wt. Actual 22.08 lb In Range Total Load Ave. MC % (wet basis) 18.0Core % of Total Wt. 55% In Range 45 65% Total Test Load Weight (dry basis) 18.11 lb 8.22 kgRemainder % of Total Wt. 45% In Range 35 55%Actual Load % of Nominal Target 100% In Range 95 105% Kindling Moisture (% dry basis)Actual Fuel Load Density 10.0 lb/ft3 11.2 11.4 11 11.2 In Range 3.60 lb 1.63 kgKindling and Start up Fuel Start up Fuel Moisture Readings (% dry basis)Maximim Kindling Wt. (20% of Tot. Load Wt.) 4.42 lb 20.3 22.8 19.5 20.9 In Range 4.96 lb 2.25 kgActual Kindling Wt. 4.00 lb In Range 18.1%Maximum Start up Fuel Wt. (30% of Tot. Load Wt.) 6.62 lb Total Wt. All Fuel Added (dry basis) 26.67 lb 12.10 kgActual Start up Fuel Wt. 6.00 lb In Range 27.2% Total Wt. All Fuel Burned (dry basis) 21.9 lb 9.9 kgAllowable Residual Start up Fuel Wt. Range 2.2 to 4.4 lb Mid PointActual Residual Start up Fuel Wt. 2.4 lb In Range 3.3Total Wt. All Fuel Added (wet basis) 32.08 lbHigh Fire Test Run End Point Range Low High Mid PointBased on Fuel Load Wt. (w/tares) 2.0 to 2.4 lb 2.2Actual Fuel Load Ending Wt. 2.4 lb In Range

Pc. Wt. Dry Basis

THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING JURISDICTION AND THE PRESIDENT OF THE SOCIETY. COPYRIGHT ASTM, 100 BARR HARBOR DRIVE, WEST CONSHOHOCKEN, PA 19428. ALL RIGHTS RESERVED.

73 of 190

Page 74: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

74 of 190

Page 75: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

75 of 190

Page 76: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 4

Low Burn

76 of 190

Page 77: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 4Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.00 ft/sec.2408 425 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 220.6 scfm Technician Signature:________________________________0028WN123E Recording Interval: 5 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 215.7 scfm28-Apr-20 Dilution Tunnel Static: -0.180 "H2O Post-Test Leak Check (1): 0.000 cfm @ 8 in. Hg

Beginning Clock Time: 16:09 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 6 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.68 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.45 29.40 "Hg Initial dP 0.090 0.092 0.092 0.072 0.090 0.090 0.088 0.082 0.091 "H2O

OMNI Equipment Numbers: Temp: 82 82 82 82 82 82 82 82 88 °FVstrav 20.00 ft/sec Vscent 20.57 ft/sec Fp 0.972

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

0 0.000 0.000 0.83 80 0.57 1.27 80 -0.1 108 0.090 26.6 568 202 296 331 365 352 357 84 74 82 75 79 -0.048 4.68 1.03

5 0.819 0.870 0.16 0.17 2.24 81 -2.11 1.76 81 -0.1 133 0.090 102 102 26.1 -0.53 488 196 287 331 356 332 422 88 71 88 75 79 -0.060 2.39 0.24

10 1.643 1.730 0.16 0.17 2.26 80 -1.85 1.69 81 -0.1 124 0.090 102 100 24.8 -1.3 607 188 272 320 341 346 560 87 71 85 75 79 -0.067 11.87 1.3

15 2.474 2.601 0.17 0.17 2.29 80 -1.99 1.78 81 -0.1 122 0.090 103 102 23.5 -1.3 715 179 255 307 323 356 529 87 71 85 75 79 -0.064 13.49 0.94

20 3.304 3.474 0.17 0.17 2.28 80 -2.03 1.77 80 -0.4 113 0.090 102 101 22.8 -0.7 734 171 240 292 309 349 463 87 72 83 75 79 -0.061 11.57 0.41

25 4.131 4.344 0.17 0.17 2.27 80 -1.96 1.76 80 -0.2 112 0.090 101 101 22.0 -0.8 754 165 227 278 297 344 468 87 72 84 76 79 -0.061 11.58 0.39

30 4.957 5.214 0.17 0.17 2.24 80 -1.97 1.77 80 -0.4 111 0.090 101 101 21.1 -0.9 755 159 215 266 287 336 455 87 73 84 76 79 -0.061 11.21 0.47

35 5.783 6.091 0.17 0.18 2.26 80 -1.96 1.78 80 -0.1 109 0.090 101 101 20.3 -0.8 734 154 206 256 278 326 429 87 74 84 76 79 -0.058 10.26 0.64

40 6.608 6.966 0.17 0.18 2.26 80 -2.19 1.77 80 -0.5 107 0.090 101 101 19.6 -0.7 711 151 198 247 270 315 418 87 74 84 76 79 -0.057 9.98 0.75

45 7.432 7.840 0.16 0.17 2.25 80 -2.45 1.76 80 -0.5 107 0.090 100 101 18.8 -0.8 712 148 193 242 264 312 431 87 73 84 76 79 -0.058 11.08 0.56

50 8.255 8.712 0.16 0.17 2.24 80 -2.05 1.78 80 -0.5 109 0.090 101 101 18.0 -0.8 746 145 187 237 259 315 456 87 73 85 76 78 -0.059 12.74 0.35

55 9.079 9.586 0.16 0.17 2.25 80 -2.08 1.77 80 -0.2 109 0.090 101 101 17.2 -0.8 755 144 182 235 257 315 455 87 73 84 76 78 -0.058 12.66 0.29

60 9.904 10.460 0.17 0.17 2.24 80 -2.21 1.77 80 -0.4 109 0.090 101 101 16.4 -0.8 764 141 179 234 256 315 456 87 72 84 77 77 -0.059 13.41 0.31

65 10.727 11.333 0.16 0.17 2.24 80 -2.05 1.77 80 -0.2 111 0.090 101 101 15.5 -0.9 769 140 177 234 256 315 466 87 73 85 77 77 -0.059 14.56 0.55

70 11.546 12.202 0.16 0.17 2.24 81 -1.76 1.75 80 -0.4 111 0.090 100 101 14.7 -0.8 784 140 176 237 257 319 469 87 73 85 77 77 -0.059 14.56 0.41

75 12.365 13.065 0.16 0.17 2.21 81 -2.11 1.71 81 -0.5 111 0.090 100 100 13.8 -0.9 793 140 176 240 260 322 465 86 73 85 77 77 -0.059 14.42 0.38

80 13.199 13.943 0.17 0.18 2.29 81 -1.84 1.78 81 -0.5 110 0.090 102 101 13.0 -0.8 791 141 176 243 263 323 457 86 73 85 77 77 -0.058 14 0.36

85 14.032 14.806 0.17 0.17 2.27 81 -1.87 1.68 81 -0.6 110 0.090 102 100 12.2 -0.8 790 141 177 246 265 324 448 86 73 84 77 78 -0.057 13.86 0.23

90 14.863 15.646 0.17 0.17 2.28 81 -1.84 1.61 81 -0.8 109 0.090 101 97 11.5 -0.7 790 141 178 249 267 325 444 86 73 84 77 78 -0.057 13.7 0.2

95 15.693 16.467 0.17 0.16 2.28 82 -1.9 1.55 81 -0.8 109 0.090 101 95 10.8 -0.7 787 142 179 251 269 326 439 86 74 85 78 78 -0.058 13.43 0.24

100 16.523 17.332 0.17 0.17 2.27 82 -2.09 1.74 81 -0.9 108 0.090 101 100 10.1 -0.7 787 142 181 254 271 327 434 85 74 85 77 79 -0.057 13.08 0.19

105 17.354 18.209 0.17 0.18 2.28 82 -1.86 1.81 82 -1.1 107 0.090 101 101 9.5 -0.6 781 143 182 257 272 327 429 85 73 85 77 79 -0.056 12.81 0.18

110 18.184 19.085 0.17 0.18 2.28 82 -2.33 1.74 82 -1.1 106 0.090 101 100 8.9 -0.6 772 142 184 259 272 326 422 85 72 84 77 77 -0.056 12.71 0.17

115 19.013 19.948 0.17 0.17 2.28 82 -2.01 1.77 82 -1.5 106 0.090 101 99 8.4 -0.5 760 140 185 262 272 324 411 85 71 84 77 78 -0.055 12.06 0.17

120 19.844 20.825 0.17 0.18 2.28 82 -2.14 1.80 82 -1.4 104 0.090 101 100 7.9 -0.5 747 140 187 265 271 322 403 85 70 84 77 77 -0.054 11.55 0.19

125 20.674 21.704 0.17 0.18 2.29 82 -2.27 1.78 82 -1.3 104 0.090 101 101 7.5 -0.4 737 139 188 267 270 320 397 85 69 85 77 78 -0.054 11.33 0.25

130 21.504 22.570 0.17 0.17 2.28 82 -1.86 1.69 82 -1.4 103 0.090 100 99 7.1 -0.4 743 138 189 269 268 321 398 85 69 84 77 77 -0.053 11.51 0.26

135 22.334 23.418 0.17 0.17 2.27 82 -2.34 1.55 82 -2.2 103 0.090 100 97 6.6 -0.5 742 138 191 270 267 322 389 85 68 84 77 77 -0.053 10.92 0.25

140 23.163 24.283 0.17 0.17 2.27 82 -2 1.80 82 -2.4 102 0.090 100 99 6.3 -0.3 714 138 193 271 267 317 373 85 68 84 77 79 -0.051 9.65 0.38

145 23.993 25.162 0.17 0.18 2.27 82 -2.3 1.77 82 -2.4 100 0.090 100 100 6.0 -0.3 697 137 194 269 266 313 368 85 68 84 77 79 -0.049 9.39 0.47

150 24.823 26.034 0.17 0.17 2.27 82 -2.07 1.78 82 -3 100 0.090 100 100 5.7 -0.3 686 137 194 268 264 310 362 84 68 84 77 78 -0.050 9.56 0.43

155 25.653 26.908 0.17 0.17 2.26 82 -2.31 1.78 82 -3 99 0.090 100 100 5.4 -0.3 666 136 195 267 262 305 352 84 67 84 77 78 -0.048 9.35 0.51

160 26.483 27.787 0.17 0.18 2.28 82 -1.87 1.81 82 -3 98 0.090 100 100 5.2 -0.2 644 136 196 269 260 301 341 84 67 84 77 79 -0.046 8.85 0.57

165 27.313 28.669 0.17 0.18 2.27 82 -2.22 1.79 81 -2.8 97 0.090 100 101 5.0 -0.2 618 136 197 271 257 296 326 84 67 83 77 79 -0.045 7.68 0.88

170 28.144 29.542 0.17 0.17 2.27 82 -2.32 1.79 82 -3.3 96 0.090 100 99 4.8 -0.2 592 137 199 271 255 291 312 84 67 84 76 79 -0.043 7.38 1.04

175 28.975 30.423 0.17 0.18 2.28 81 -1.91 1.80 82 -3 95 0.090 100 100 4.7 -0.1 565 135 201 269 251 284 305 84 67 84 77 75 -0.043 7.58 1.01

180 29.806 31.306 0.17 0.18 2.29 82 -1.92 1.80 82 -3.1 95 0.090 100 100 4.5 -0.2 548 134 203 268 247 280 300 83 67 84 77 77 -0.041 7.56 1.11

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 10 Medium Burn Run 4

77 of 190

e:_________________________________________ ______________________________________ _____________________

Page 78: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 4Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.00 ft/sec.2408 425 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 220.6 scfm Technician Signature:________________________________0028WN123E Recording Interval: 5 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 215.7 scfm28-Apr-20 Dilution Tunnel Static: -0.180 "H2O Post-Test Leak Check (1): 0.000 cfm @ 8 in. Hg

Beginning Clock Time: 16:09 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 6 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.68 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.45 29.40 "Hg Initial dP 0.090 0.092 0.092 0.072 0.090 0.090 0.088 0.082 0.091 "H2O

OMNI Equipment Numbers: Temp: 82 82 82 82 82 82 82 82 88 °FVstrav 20.00 ft/sec Vscent 20.57 ft/sec Fp 0.972

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

185 30.637 32.190 0.17 0.18 2.29 82 -2.2 1.81 82 -3.3 94 0.090 100 100 4.4 -0.1 532 134 206 266 244 276 294 83 68 84 77 77 -0.040 7.62 1.25

190 31.469 33.079 0.17 0.18 2.30 82 -2.09 1.84 82 -3.2 93 0.090 100 101 4.2 -0.2 516 133 210 264 241 273 285 83 68 84 77 76 -0.038 7.19 1.41

195 32.301 33.964 0.17 0.18 2.29 82 -2.21 1.79 82 -3 92 0.090 100 100 4.1 -0.1 513 134 213 262 241 273 281 83 68 84 77 78 -0.040 7.75 0.92

200 33.133 34.847 0.17 0.18 2.29 82 -1.88 1.81 82 -2.9 92 0.090 100 100 4.0 -0.1 509 134 215 260 242 272 280 83 68 84 76 77 -0.041 7.64 0.98

205 33.966 35.732 0.17 0.18 2.29 82 -2.29 1.82 82 -2.8 91 0.090 100 100 3.8 -0.2 502 136 216 258 245 271 278 83 68 84 76 77 -0.041 7.55 1.23

210 34.798 36.622 0.17 0.18 2.29 82 -1.84 1.83 82 -2.9 91 0.090 100 101 3.7 -0.1 495 137 217 257 247 271 271 83 68 84 76 78 -0.040 7.06 1.6

215 35.629 37.514 0.17 0.18 2.28 81 -1.89 1.85 82 -2.7 91 0.090 100 101 3.6 -0.1 483 137 217 255 249 268 269 83 68 84 76 78 -0.038 7.74 1.31

220 36.461 38.410 0.17 0.18 2.28 81 -2.12 1.85 81 -2.7 90 0.090 100 102 3.4 -0.2 474 137 218 253 250 266 264 84 69 83 76 78 -0.038 7.15 1.54

225 37.293 39.309 0.17 0.18 2.29 81 -2.13 1.87 81 -3 90 0.090 100 102 3.3 -0.1 460 138 220 251 250 264 260 84 69 83 76 77 -0.038 7.06 1.55

230 38.124 40.198 0.17 0.18 2.29 81 -2.23 1.79 81 -2.8 90 0.090 100 101 3.2 -0.1 455 138 221 248 250 262 256 84 69 83 76 76 -0.037 7.14 1.57

235 38.956 41.076 0.17 0.18 2.28 81 -2.03 1.80 81 -2.6 89 0.090 100 99 3.1 -0.1 449 137 223 246 250 261 253 84 69 83 76 76 -0.036 7.12 1.46

240 39.788 41.957 0.17 0.18 2.29 81 -1.89 1.81 81 -2.6 89 0.090 100 100 3.0 -0.1 440 137 225 245 250 259 248 85 69 83 76 77 -0.036 6.94 1.45

245 40.619 42.840 0.17 0.18 2.29 81 -1.86 1.80 81 -2.6 89 0.090 100 100 2.9 -0.1 434 137 226 243 250 258 245 85 69 83 76 76 -0.035 6.66 1.63

250 41.450 43.724 0.17 0.18 2.29 81 -2.21 1.80 81 -2.5 88 0.090 99 100 2.8 -0.1 426 136 226 241 249 256 243 85 69 83 76 76 -0.035 6.78 1.64

255 42.280 44.609 0.17 0.18 2.29 81 -2.02 1.80 81 -2.6 88 0.090 99 100 2.7 -0.1 422 138 227 239 250 255 238 85 70 83 75 77 -0.034 6.61 1.68

260 43.111 45.496 0.17 0.18 2.29 81 -2.21 1.83 81 -2.5 88 0.090 99 100 2.6 -0.1 415 137 225 237 250 253 240 85 70 83 75 77 -0.034 6.72 1.65

265 43.942 46.378 0.17 0.18 2.29 80 -2.18 1.77 81 -2.5 88 0.090 100 100 2.5 -0.1 414 136 225 235 249 252 237 85 70 83 75 76 -0.036 6.46 1.79

270 44.773 47.253 0.17 0.18 2.27 80 -2.3 1.78 81 -2.3 87 0.090 100 99 2.4 -0.1 409 134 224 233 248 250 233 85 70 83 75 76 -0.036 6.3 1.69

275 45.603 48.131 0.17 0.18 2.27 80 -1.99 1.79 80 -2.3 87 0.090 99 99 2.3 -0.1 404 133 224 231 246 248 232 85 70 83 75 75 -0.035 5.99 1.71

280 46.433 49.010 0.17 0.18 2.27 80 -2.32 1.80 80 -2.3 87 0.090 99 100 2.2 -0.1 397 132 224 229 245 245 229 85 70 83 75 76 -0.035 5.82 1.78

285 47.263 49.891 0.17 0.18 2.27 80 -2.3 1.79 80 -2.6 86 0.090 99 100 2.1 -0.1 386 131 224 227 243 242 226 85 70 83 75 75 -0.035 5.61 1.86

290 48.093 50.773 0.17 0.18 2.27 80 -1.85 1.81 80 -2.6 86 0.090 99 100 2.0 -0.1 379 130 224 225 241 240 223 85 70 83 75 75 -0.035 5.52 1.95

295 48.923 51.658 0.17 0.18 2.27 80 -2.22 1.82 80 -2.4 86 0.090 99 100 1.9 -0.1 371 129 223 223 238 237 221 85 70 83 75 75 -0.034 5.24 1.99

300 49.753 52.545 0.17 0.18 2.28 80 -2.19 1.83 80 -2.4 86 0.090 99 100 1.8 -0.1 365 128 223 220 236 234 216 85 71 83 75 76 -0.033 5.15 2.02

305 50.583 53.434 0.17 0.18 2.28 80 -1.89 1.84 80 -2.3 85 0.090 99 100 1.7 -0.1 358 127 224 218 233 232 212 85 71 83 75 76 -0.033 5.15 1.88

310 51.413 54.327 0.17 0.18 2.28 80 -2.05 1.86 80 -2.3 85 0.090 99 101 1.7 0 351 126 224 215 230 229 209 85 71 82 75 76 -0.032 5.13 1.91

315 52.243 55.216 0.17 0.18 2.29 79 -1.88 1.78 80 -2.2 85 0.090 99 100 1.6 -0.1 344 124 225 213 226 226 205 85 71 83 75 76 -0.032 5.03 1.92

320 53.074 56.095 0.17 0.18 2.28 79 -2.31 1.80 80 -2.2 84 0.090 99 99 1.5 -0.1 339 123 226 211 223 224 203 84 71 83 75 76 -0.032 5.27 1.86

325 53.904 56.974 0.17 0.18 2.29 79 -2.05 1.81 79 -2.3 84 0.090 99 99 1.4 -0.1 336 121 228 209 219 223 201 84 71 82 75 75 -0.032 5.25 1.86

330 54.734 57.857 0.17 0.18 2.29 79 -1.81 1.81 79 -2.2 84 0.090 99 100 1.4 0 332 120 228 208 216 221 199 84 71 82 75 76 -0.032 5.29 1.8

335 55.565 58.740 0.17 0.18 2.29 79 -2.07 1.82 79 -2.2 84 0.090 99 100 1.3 -0.1 328 120 228 207 212 219 198 84 71 82 75 74 -0.032 5.14 1.81

340 56.395 59.626 0.17 0.18 2.28 79 -2.25 1.83 79 -2.4 84 0.090 99 100 1.2 -0.1 326 119 229 206 210 218 195 84 71 83 74 75 -0.031 5.12 1.82

345 57.224 60.513 0.17 0.18 2.29 79 -1.93 1.83 79 -2.1 84 0.090 99 100 1.1 -0.1 324 118 230 206 208 217 195 84 71 83 74 76 -0.031 5.15 1.85

350 58.054 61.401 0.17 0.18 2.26 79 -2.25 1.84 79 -2.4 83 0.090 99 100 1.0 -0.1 320 118 230 204 205 215 193 84 71 82 74 76 -0.031 5.29 1.78

355 58.883 62.276 0.17 0.18 2.27 79 -2.31 1.79 79 -2 83 0.090 99 99 1.0 0 316 115 229 202 202 213 193 84 71 83 74 75 -0.031 5.26 1.86

360 59.712 63.152 0.17 0.18 2.27 79 -2.12 1.78 79 -2.3 83 0.090 99 99 0.9 -0.1 314 114 228 200 200 211 193 84 71 82 74 76 -0.031 5.25 1.87

365 60.541 64.028 0.17 0.18 2.28 79 -2.1 1.80 79 -2.3 83 0.090 99 99 0.8 -0.1 310 112 227 198 199 209 189 84 71 82 74 75 -0.031 4.78 1.95

Control No. P-SSAR-0003 Page 6 of 10 Medium Burn Run 4

78 of 190

ure:______________________________

Page 79: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 4Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.00 ft/sec.2408 425 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 220.6 scfm Technician Signature:________________________________0028WN123E Recording Interval: 5 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 215.7 scfm28-Apr-20 Dilution Tunnel Static: -0.180 "H2O Post-Test Leak Check (1): 0.000 cfm @ 8 in. Hg

Beginning Clock Time: 16:09 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 6 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 19.68 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.35 29.45 29.40 "Hg Initial dP 0.090 0.092 0.092 0.072 0.090 0.090 0.088 0.082 0.091 "H2O

OMNI Equipment Numbers: Temp: 82 82 82 82 82 82 82 82 88 °FVstrav 20.00 ft/sec Vscent 20.57 ft/sec Fp 0.972

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

370 61.370 64.906 0.17 0.18 2.28 79 -1.83 1.78 79 -2 83 0.090 99 99 0.7 -0.1 305 111 226 195 197 207 186 83 71 82 74 76 -0.030 4.74 2

375 62.200 65.785 0.17 0.18 2.28 79 -2.26 1.79 79 -2 83 0.090 99 99 0.7 0 302 110 223 193 196 205 185 83 71 82 74 76 -0.030 4.64 2.06

380 63.029 66.664 0.17 0.18 2.29 79 -1.83 1.80 79 -1.9 83 0.090 99 99 0.6 -0.1 301 110 222 191 195 204 184 83 72 82 74 75 -0.029 5.25 1.46

385 63.859 67.546 0.17 0.18 2.27 79 -1.82 1.80 79 -1.9 82 0.090 99 100 0.5 -0.1 299 109 220 189 194 202 183 83 72 82 74 75 -0.029 5.22 1.44

390 64.688 68.426 0.17 0.18 2.29 79 -1.82 1.81 79 -2 82 0.090 99 99 0.5 0 297 107 219 187 192 200 181 83 72 83 74 76 -0.028 5.22 1.43

395 65.517 69.307 0.17 0.18 2.27 79 -2.09 1.82 79 -1.9 82 0.090 99 99 0.4 -0.1 296 106 219 186 191 200 179 83 72 82 74 76 -0.028 5.23 1.42

400 66.346 70.188 0.17 0.18 2.27 79 -2.17 1.82 79 -2.1 82 0.090 99 99 0.3 -0.1 295 106 217 185 190 199 179 83 72 82 74 76 -0.029 4.88 1.6

405 67.174 71.070 0.17 0.18 2.28 78 -2.13 1.81 79 -2.1 82 0.090 99 100 0.3 0 293 105 216 183 189 197 180 83 72 82 74 75 -0.029 4.97 1.47

410 68.003 71.952 0.17 0.18 2.28 78 -1.88 1.81 78 -2.2 82 0.090 99 100 0.2 -0.1 290 105 216 183 188 196 179 83 72 82 74 75 -0.029 4.8 1.6

415 68.832 72.835 0.17 0.18 2.29 78 -1.86 1.81 78 -2.2 82 0.090 99 100 0.1 -0.1 287 104 215 182 187 195 178 83 72 82 74 74 -0.028 4.64 1.71

420 69.661 73.718 0.17 0.18 2.29 78 -1.83 1.83 78 -1.9 82 0.090 99 100 0.1 0 285 105 214 181 187 194 176 83 72 82 74 75 -0.028 4.87 1.41

425 70.490 74.601 0.17 0.18 2.29 78 -1.81 1.82 78 -2.1 82 0.090 99 100 0.0 -0.1 283 105 214 181 187 194 176 83 72 82 74 75 -0.028 4.91 1.41Avg/Tot 70.490 74.601 0.17 0.18 2.26 80 1.78 80 95 0.090 100 100 158.4 71 83 76 77 -0.043

Control No. P-SSAR-0003 Page 7 of 10 Medium Burn Run 4

79 of 190

e:________________________________

Page 80: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis Industries Equipment Numbers: Model: Medium Flush Wood

Tracking No.: 2408Project No.: 0028WN123E

Run #: 4Date: 4/28/20

TRAIN 1 (First Hour emissions)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg B. Front filter catch Filter T240S 107.1 98.5 8.6 C. Rear filter catch Filter 0.0 D. Probe catch* Probe 0.0 E. Filter seals catch* Seals 0.0

Sub-Total Total Particulate, mg: 8.6

TRAIN 1 (Post First Hour Change-out)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg B. Front filter catch Filter T230AP 199.0 197.8 1.2 C. Rear filter catch Filter 0.0 D. Probe catch* Probe 28 114752.2 114750.8 1.4 E. Filter seals catch* Seals R968 3353.7 3353.6 0.1

Sub-Total Total Particulate, mg: 2.7

Train 1 Aggregate Total Particulate, mg: 11.3

TRAIN 2Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mg A. Front filter catch Filter T230BP 206.3 197.1 9.2 B. Rear filter catch Filter 0.0 C. Probe catch* Probe 29 114278.0 114276.7 1.3 D. Filter seals catch* Seals R969 3560.2 3559.9 0.3

Total Particulate, mg: 10.8

AMBIENTSample Component Reagent Filter # or Weights

Probe # Final, mg Tare, mg Particulate, mg A. Front filter catch* Filter 0.0

Total Particulate, mg: 0.0

Component Equations: A. Front filter catch Final (mg) - Tare (mg) = Particulate, mg B. Rear filter catch Final (mg) - Tare (mg) = Particulate, mg C. Probe catch Final (mg) - Tare (mg) = Particulate, mg

Technician Signature:_____________________________________________________

*Particulate catch that results in a negative number, is assumed to be zero for probes and seals, negative numbers for filters are assumed to be part of the seal weight.

Wood Heater Lab Data - ASTM E23053 / ASTM E2515

Control No. P-SSAR-0003 Medium Burn Run 480 of 190

:__________________________________________________________ _________________________________ _____ _____________________________________________________________________________________________________

Page 81: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN123ETracking No.: 2408

Run: 4Test Date:

Burn Rate 1.43 kg/hr dry

Average Tunnel Temperature 95 degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs 20.00 feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd 12942.8 dscf/hour

Average Delta p 0.090 inches H20Total Time of Test 425 minutes

Total Sample Volume - Vm 0.000 cubic feet 70.490 cubic feet 74.601 cubic feet 9.904 cubic feetAverage Gas Meter Temperature 77 degrees Fahrenheit 80 degrees Fahrenheit 80 degrees Fahrenheit 81 degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd 0.000 dscf 67.213 dscf 70.825 dscf 9.432 dscf

Total Particulates - mn 0 mg 11.3 mg 10.8 mg 8.6 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf 0.00017 grams/dscf 0.00015 grams/dscf 0.00091 grams/dscfTotal Particulate Emissions - ET 0.00 grams 15.41 grams 13.98 grams 11.80 gramsParticulate Emission Rate 0.00 grams/hour 2.18 grams/hour 1.97 grams/hour 11.80 grams/hourEmissions Factor 1.52 g/kg 1.38 g/kg 3.04 g/kg

Difference from Average Total Particulate Emissions 0.72 grams 0.72 grams

Complete Test RunTotal Particulate Emissions - ET 14.70 gramsParticulate Emission Rate 2.07 grams/hourEmissions Factor 1.45 grams/kg

First Hour EmissionsTotal Particulate Emissions - ET 11.80 gramsParticulate Emission Rate 11.80 grams/hourEmissions Factor 3.04 grams/kg

7.5% of Average Total Particulate Emissions 1.10 grams

Technician Signature:_____________________________________________________

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/28/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

Dual Train Comparison Results Are Acceptable

Filter Temps < 90 °F OKOKOKOK

Stove Surface ∆T NOT ACCEPTABLE

OK

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.OKPro-Rate Variation OK

Control No. P-SSAR-0003 Medium Burn Run 481 of 190

:____________________________ ______________ ______

Page 82: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Manufacturer: Travis Industries Technician Signature:Model:edium Flush Wood

Date: 04/28/20Run: 4

Control #: 0028WN123E Test Duration: 425

Output Category: III

HHV Basis LHV BasisOverall Efficiency 71.9% 77.7%

Combustion Efficiency 94.3% 94.3%Heat Transfer Efficiency 76% 82.4%

Output Rate (kJ/h) 20,293 19,250 (Btu/h)Burn Rate (kg/h) 1.43 3.14 (lb/h)

Input (kJ/h) 28,234 26,783 (Btu/h)

Test Load Weight (dry kg) 10.10 22.25 dry lbMC wet (%) 16.44617741MC dry (%) 19.68

Particulate (g ) 2.07CO (g) 815

Test Duration (h) 7.08

Emissions Particulate COg/MJ Output 0.01 5.67

g/kg Dry Fuel 0.21 80.73g/h 0.29 115.06

lb/MM Btu Output 0.03 13.18

Air/Fuel Ratio (A/F) 11.47

VERSION: 2.2 12/14/2009

Test Results in Accordance with CSA B415.1-09

Wood Heater Efficiency Results - CSA B415.1

82 of 190

Page 83: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 VersionCordwood Fuel Load Calculators 12 lb/ft3 Nominal Load DensityCore 45 65% of Total Load Weight, Remainder 35 55% of Total Load Weight

Values to be input manuallyFor Usable Firebox Volumes up to 3.0 ft3 Low and Medium Fire

Nominal Required Load Density (wet basis) 12 lb/ft3

Usable Firebox Volume 2.20 ft3

Total Nom. Load Wt. Target 26.4 lbTotal Load Wt. Allowable Range 25.08 to 27.72 lbCore Target Wt. Allowable Range 11.88 to 17.16 lbRemainder Load Wt. Allowable Range 9.24 to 14.52 lb

Mid PointCore Load Fuel Pc. Wt. Allowable Range 3.96 to 6.60 lb 5.28Remainder Load Pc. Wt. Allowable Range 2.64 to 7.92 lb 5.28 Fuel Piece Moisture Reading (% dry basis)

Pc. # 1 2 3 Ave.Core Load Piece Wt. Actual 1 5.97 lb In Range 19.3 18.6 18.8 18.9 In Range 5.02 lb 2.28 kg

2 4.27 lb In Range 18.9 23.2 18.4 20.2 In Range 3.55 lb 1.61 kg3 4.25 lb In Range 22.7 21.3 24.5 22.8 In Range 3.46 lb 1.57 kg

Core Load Total. Wt. Actual 14.48 lb In RangePc. #

Remainder Load Piece Wt. 1 5.50 lb In Range 20 17.6 18.8 18.8 In Range 4.63 lb 2.10 kg(2 or 3 Pcs.) 2 3.55 lb In Range 18.7 20.5 17.9 19.0 In Range 2.98 lb 1.35 kg

3 3.11 lb In Range 17.9 18 19.2 18.4 In Range 2.63 lb 1.19 kgRemainder Load Piece Weight Ratio Small/Large 57% In Range 67% Total Load Ave. MC % (dry basis) 19.6 In RangeRemainder Load Tot. Wt. Act 12.15 lb In Range Total Load Ave. MC % (wet basis) 16.4Total Load Wt. Actual 26.63 lb In Range Total Test Load Weight (dry basis) 22.25 lb 10.09 kgCore % of Total Wt. 54% In Range 45 65% Total Fuel Weight Burned During Test Run (dry basis) 22.3 lb 10.09 kgRemainder % of Total Wt. 46% In Range 35 55%Actual Load % of Nominal Target 101% In Range 95 105%Actual Fuel Load Density 12.1 lb/ft3

Allowable Charcoal Bed Wt. Range (lb) 2.7 to 5.3 Mid PointActual Charcoal Bed Wt. 4.1 lb In Range 4.0Actual Fuel Load Ending Wt. 0.0 lb Valid Test 90%Total Wt. of Fuel Burned During Test Run lb. 26.6 lb

Pc. Wt. Dry Basis

THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING JURISDICTION AND THE PRESIDENT OF THE SOCIETY. COPYRIGHT ASTM, 100 BARR HARBOR DRIVE, WEST CONSHOHOCKEN, PA 19428. ALL RIGHTS RESERVED.

83 of 190

Page 84: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

84 of 190

Page 85: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

85 of 190

Page 86: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 5

High Burn

86 of 190

Page 87: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.01 ft/sec.2408 174 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 223.8 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.3 scfm30-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.29 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP 0.090 0.090 0.092 0.074 0.086 0.090 0.096 0.080 0.094 "H2O

OMNI Equipment Numbers: Temp: 71 71 71 71 71 71 71 71 71 °FVstrav 19.83 ft/sec Vscent 20.51 ft/sec Fp 0.967

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

0 0.000 0.000 1.74 71 -1.03 1.37 71 0.2 71 0.090 10.5 71 71 72 71 71 71 70 81 67 83 67 69 -0.004 0.05 0

1 0.149 0.156 0.15 0.16 2.31 71 -1.74 1.74 71 0 71 0.090 88 86 10.5 0 77 71 72 71 71 72 79 80 66 81 67 69 -0.006 0.53 0.01

2 0.314 0.327 0.17 0.17 2.30 71 -1.98 1.72 71 0.1 71 0.090 98 94 10.5 0 80 71 72 71 71 73 78 80 66 80 67 69 -0.005 1.9 0.06

3 0.478 0.497 0.16 0.17 2.26 71 -1.76 1.70 71 0.1 71 0.090 97 94 10.5 0 83 71 72 71 71 74 76 80 66 80 68 69 -0.002 5.52 0.4

4 0.641 0.667 0.16 0.17 2.25 71 -1.99 1.70 71 -0.1 71 0.090 97 94 10.4 -0.1 88 71 72 71 71 75 87 80 66 79 68 69 -0.008 2.55 0.25

5 0.806 0.841 0.17 0.17 2.31 71 -1.67 1.82 71 -0.2 71 0.090 98 96 10.4 0 91 71 72 72 71 75 96 80 66 79 68 69 -0.011 5.84 0.8

6 0.972 1.016 0.17 0.18 2.31 71 -2.05 1.81 71 0 71 0.090 98 97 10.4 0 93 71 72 72 71 76 102 80 66 79 68 69 -0.012 4.37 0.74

7 1.136 1.191 0.16 0.18 2.28 71 -1.67 1.79 71 -0.1 71 0.090 97 97 10.3 -0.1 95 71 72 72 72 76 108 80 66 79 68 69 -0.014 3.88 0.6

8 1.300 1.364 0.16 0.17 2.28 71 -1.8 1.79 71 -0.1 72 0.090 97 96 10.3 0 99 71 72 72 72 77 115 80 66 80 68 69 -0.016 3.56 0.29

9 1.464 1.538 0.16 0.17 2.28 71 -2.04 1.77 71 -0.2 72 0.100 92 91 10.3 0 102 71 72 73 73 78 121 80 66 80 68 69 -0.017 3.19 0.28

10 1.628 1.711 0.16 0.17 2.26 71 -1.96 1.76 71 -0.1 72 0.090 97 96 10.2 -0.1 106 71 73 73 73 79 129 80 66 80 68 69 -0.019 3.59 0.21

11 1.791 1.886 0.16 0.18 2.25 71 -1.57 1.76 71 -0.2 73 0.090 97 97 10.2 0 113 71 73 74 74 81 142 80 66 80 68 69 -0.022 4.29 0.25

12 1.956 2.058 0.17 0.17 2.31 71 -1.69 1.81 71 -0.2 73 0.090 98 95 10.1 -0.1 121 71 74 74 74 83 156 80 66 80 68 69 -0.024 4.19 0.21

13 2.122 2.233 0.17 0.18 2.31 71 -1.92 1.81 71 0.1 74 0.090 99 97 10.0 -0.1 127 72 74 75 75 85 164 80 65 80 68 69 -0.025 4.11 0.17

14 2.286 2.409 0.16 0.18 2.28 71 -1.7 1.81 71 -0.2 74 0.090 97 97 9.9 -0.1 135 72 75 76 76 87 179 80 65 80 68 69 -0.029 4.29 0.26

15 2.450 2.582 0.16 0.17 2.28 71 -1.76 1.80 71 0.1 75 0.090 97 96 9.9 0 143 72 75 76 77 89 194 80 65 80 68 69 -0.030 5.21 0.27

16 2.614 2.757 0.16 0.18 2.28 71 -1.81 1.78 71 0.1 76 0.090 98 97 9.8 -0.1 154 72 76 78 78 92 207 81 65 80 68 69 -0.032 5.01 0.28

17 2.778 2.930 0.16 0.17 2.25 71 -1.64 1.77 71 0.1 77 0.090 98 96 9.7 -0.1 168 73 77 79 79 95 225 81 65 80 68 69 -0.035 5.45 0.25

18 2.941 3.104 0.16 0.17 2.26 71 -2.03 1.77 71 0.1 78 0.090 97 97 9.6 -0.1 180 73 78 80 81 98 237 81 65 80 68 69 -0.037 5.76 0.19

19 3.104 3.276 0.16 0.17 2.26 71 -2.08 1.77 71 -0.1 79 0.090 97 96 9.5 -0.1 192 73 79 81 82 101 252 81 65 80 68 69 -0.038 5.72 0.26

20 3.268 3.448 0.16 0.17 2.25 71 -2.14 1.75 71 0.1 80 0.090 98 96 9.4 -0.1 206 74 80 83 83 105 260 81 65 81 68 69 -0.038 5.82 0.3

21 3.430 3.620 0.16 0.17 2.24 71 -1.67 1.74 71 -0.1 81 0.090 97 96 9.3 -0.1 220 74 81 85 85 109 271 81 64 81 68 69 -0.042 5.7 0.35

22 3.593 3.793 0.16 0.17 2.32 71 -2.25 1.81 71 -0.2 83 0.090 98 97 9.2 -0.1 235 75 82 87 87 113 287 81 64 81 68 69 -0.043 6.51 0.36

23 3.758 3.968 0.17 0.18 2.31 71 -2.19 1.81 71 -0.1 83 0.090 99 98 9.1 -0.1 244 75 84 89 88 116 296 82 64 81 68 69 -0.043 6.55 0.32

24 3.923 4.143 0.17 0.18 2.30 71 -2.22 1.79 71 0 85 0.090 99 98 8.9 -0.2 263 76 86 91 90 121 311 82 64 81 68 69 -0.045 6.48 0.33

25 4.087 4.316 0.16 0.17 2.30 71 -2.26 1.79 71 -0.3 86 0.090 98 97 8.7 -0.2 280 77 87 93 92 126 324 82 64 81 68 70 -0.047 7.09 0.36

26 4.252 4.491 0.17 0.18 2.29 72 -2.26 1.78 71 -0.1 88 0.090 99 98 8.6 -0.1 291 77 89 96 94 129 333 82 64 81 68 70 -0.049 7.12 0.45

27 4.416 4.664 0.16 0.17 2.28 72 -2 1.78 71 -0.3 89 0.090 99 97 8.5 -0.1 307 78 92 100 97 135 348 83 64 81 68 70 -0.050 7.4 0.54

28 4.580 4.837 0.16 0.17 2.27 72 -1.84 1.77 72 -0.1 91 0.090 99 97 8.2 -0.3 330 79 94 103 100 141 371 83 64 82 68 69 -0.054 7.58 0.48

29 4.743 5.010 0.16 0.17 2.27 72 -2.03 1.75 71 0 94 0.090 98 98 8.1 -0.1 363 80 96 107 103 150 410 83 64 82 68 70 -0.056 8.55 0.45

30 4.906 5.183 0.16 0.17 2.25 72 -2.28 1.81 71 -0.1 95 0.090 99 98 8.0 -0.1 390 81 99 111 106 157 422 83 64 82 68 70 -0.055 8.85 0.38

31 5.069 5.358 0.16 0.18 2.24 72 -2.04 1.82 72 -0.2 97 0.090 99 99 7.8 -0.2 416 83 102 115 109 165 430 84 64 83 69 70 -0.057 8.03 0.4

32 5.232 5.533 0.16 0.18 2.25 72 -2.09 1.81 72 -0.1 98 0.090 99 99 7.5 -0.3 440 84 105 120 113 172 444 84 64 83 69 70 -0.058 8.68 0.34

33 5.394 5.708 0.16 0.18 2.22 72 -2.18 1.81 72 -0.4 99 0.090 98 99 7.3 -0.2 460 86 108 124 116 179 453 84 64 83 69 70 -0.058 8.8 0.3

34 5.557 5.882 0.16 0.17 2.29 72 -1.95 1.80 72 -0.3 101 0.090 99 99 7.2 -0.1 479 87 111 128 120 185 461 84 64 83 69 70 -0.059 8.99 0.28

35 5.721 6.057 0.16 0.18 2.29 72 -2.1 1.79 72 -0.3 102 0.090 100 99 7.1 -0.1 501 89 114 131 124 192 472 84 63 83 69 70 -0.060 9.28 0.28

36 5.885 6.230 0.16 0.17 2.27 72 -1.95 1.78 72 -0.2 104 0.090 100 98 6.9 -0.2 522 92 117 134 128 199 483 85 64 83 69 70 -0.061 9.57 0.23

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 12 High Burn Run 5

87 of 190

e:________________________________________________

Page 88: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.01 ft/sec.2408 174 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 223.8 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.3 scfm30-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.29 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP 0.090 0.090 0.092 0.074 0.086 0.090 0.096 0.080 0.094 "H2O

OMNI Equipment Numbers: Temp: 71 71 71 71 71 71 71 71 71 °FVstrav 19.83 ft/sec Vscent 20.51 ft/sec Fp 0.967

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

37 6.048 6.404 0.16 0.17 2.28 72 -1.93 1.78 72 -0.4 105 0.090 99 99 6.8 -0.1 538 94 121 138 132 205 493 85 64 83 69 70 -0.061 9.91 0.22

38 6.212 6.577 0.16 0.17 2.27 72 -2.37 1.78 72 -0.4 106 0.090 100 98 6.6 -0.2 553 96 124 141 136 210 494 85 63 83 69 70 -0.061 9.77 0.19

39 6.376 6.750 0.16 0.17 2.25 72 -2.39 1.77 72 -0.1 106 0.090 100 98 6.4 -0.2 564 99 127 146 141 215 494 85 64 84 69 71 -0.061 9.4 0.19

40 6.538 6.922 0.16 0.17 2.25 72 -1.91 1.75 72 -0.3 106 0.090 99 98 6.2 -0.2 571 102 130 150 145 220 489 85 64 84 69 71 -0.060 9.05 0.16

41 6.701 7.093 0.16 0.17 2.25 72 -2.32 1.74 72 -0.2 107 0.090 100 97 6.1 -0.1 576 105 132 155 150 224 491 85 64 84 69 71 -0.061 8.92 0.14

42 6.864 7.265 0.16 0.17 2.21 72 -2.09 1.72 72 -0.1 107 0.090 100 98 5.9 -0.2 581 108 135 161 155 228 487 85 64 84 69 71 -0.060 8.72 0.15

43 7.027 7.438 0.16 0.17 2.27 72 -2.02 1.82 72 -0.3 107 0.090 100 98 5.7 -0.2 586 111 139 166 159 232 485 85 64 84 69 71 -0.060 8.5 0.16

44 7.191 7.614 0.16 0.18 2.28 72 -2.31 1.81 72 -0.4 107 0.090 100 100 5.6 -0.1 591 114 141 171 164 236 485 85 64 84 69 71 -0.061 8.64 0.16

45 7.355 7.789 0.16 0.18 2.27 72 -2.05 1.80 72 -0.2 108 0.090 100 100 5.5 -0.1 598 117 145 176 170 241 490 85 64 84 69 71 -0.062 8.63 0.15

46 7.518 7.963 0.16 0.17 2.26 72 -2.46 1.79 72 -0.3 108 0.090 100 99 5.3 -0.2 608 121 148 182 175 247 494 85 64 84 69 71 -0.061 9.14 0.1

47 7.681 8.137 0.16 0.17 2.24 72 -2.07 1.77 72 -0.6 109 0.090 100 99 5.2 -0.1 616 124 151 187 180 252 494 85 64 84 70 71 -0.061 8.99 0.09

48 7.844 8.309 0.16 0.17 2.23 72 -2.23 1.76 72 -0.3 109 0.090 100 98 5.0 -0.2 623 128 155 192 185 257 496 86 64 84 70 71 -0.061 9.05 0.08

49 8.006 8.482 0.16 0.17 2.23 72 -2.54 1.75 72 -0.3 109 0.090 99 99 4.9 -0.1 630 131 158 197 190 261 497 86 64 84 70 72 -0.061 8.99 0.08

50 8.168 8.653 0.16 0.17 2.22 72 -2.44 1.75 72 -0.6 109 0.090 99 98 4.7 -0.2 636 135 162 203 196 266 490 86 64 84 70 71 -0.061 9.29 0.07

51 8.333 8.827 0.17 0.17 2.29 72 -2.17 1.80 72 -0.3 109 0.090 101 99 4.6 -0.1 637 138 166 208 202 270 484 86 64 84 70 71 -0.060 8.39 0.1

52 8.497 9.001 0.16 0.17 2.27 73 -2.27 1.79 72 -0.7 109 0.090 100 99 4.5 -0.1 636 142 170 213 208 274 478 86 64 84 70 70 -0.060 7.92 0.14

53 8.661 9.175 0.16 0.17 2.27 73 -2.17 1.77 72 -0.4 108 0.090 100 99 4.4 -0.1 634 146 174 219 213 277 473 86 64 84 70 70 -0.060 7.69 0.15

54 8.825 9.348 0.16 0.17 2.30 73 -2.63 1.80 73 -0.8 107 0.090 100 98 4.3 -0.1 628 139 171 220 214 274 465 86 64 84 70 70 -0.059 7.27 0.19

55 8.990 9.522 0.17 0.17 2.29 73 -2.31 1.76 73 -0.5 106 0.090 101 99 4.2 -0.1 622 133 166 218 213 270 450 86 64 84 70 71 -0.057 7.23 0.26

56 9.154 9.693 0.16 0.17 2.29 73 -2.34 1.73 73 -0.8 105 0.090 100 97 4.1 -0.1 618 131 164 216 213 268 440 85 64 84 70 70 -0.057 7.13 0.35

57 9.319 9.865 0.17 0.17 2.28 73 -2.79 1.78 73 -0.8 105 0.090 100 98 4.0 -0.1 608 130 162 214 213 265 430 85 64 83 70 70 -0.056 7.12 0.41

58 9.483 10.039 0.16 0.17 2.26 73 -2.38 1.78 73 -0.7 104 0.090 100 99 3.9 -0.1 598 130 162 213 213 263 420 85 64 83 71 71 -0.055 6.72 0.46

59 9.628 10.210 0.15 0.17 2.35 73 -1.66 1.74 73 -0.7 104 0.090 88 97 3.7 -0.2 590 130 161 212 213 261 418 85 64 83 71 71 -0.055 6.71 0.45

60 9.790 10.383 0.16 0.17 2.23 73 -2.11 1.75 73 -1.1 103 0.090 98 98 3.6 -0.1 584 130 162 212 214 260 415 85 64 83 71 72 -0.055 6.95 0.4

61 9.954 10.554 0.16 0.17 2.26 73 -2.02 1.74 73 -0.8 103 0.090 100 97 3.5 -0.1 581 130 162 212 215 260 418 85 64 83 71 72 -0.054 7.4 0.33

62 10.117 10.726 0.16 0.17 2.23 73 -1.79 1.82 73 -1 103 0.090 99 97 3.5 0 577 131 162 212 216 260 417 85 64 83 71 72 -0.054 7.47 0.32

63 10.280 10.901 0.16 0.17 2.32 73 -2.07 1.80 73 -1.1 103 0.090 99 99 3.4 -0.1 573 131 163 212 217 259 417 85 64 83 71 72 -0.054 7.28 0.33

64 10.446 11.069 0.17 0.17 2.28 73 -1.88 1.40 73 -1.5 134 0.090 104 98 21.8 18.4 562 134 164 213 219 258 451 86 64 83 71 72 -0.058 7.37 0.33

65 10.611 11.229 0.17 0.16 2.26 73 -2.14 1.61 73 -7.2 135 0.090 103 93 21.3 -0.5 548 134 166 215 221 257 459 87 64 83 71 73 -0.064 2.42 0.23

66 10.774 11.397 0.16 0.17 2.28 73 -1.97 1.76 73 -11.1 136 0.090 102 98 21.1 -0.2 576 134 168 217 223 264 575 87 64 84 71 73 -0.061 7.05 0.37

67 10.938 11.574 0.16 0.18 2.30 73 -1.91 1.91 73 -9.8 122 0.090 101 102 20.7 -0.4 609 136 169 218 225 271 526 87 64 84 71 73 -0.060 10.49 0.58

68 11.103 11.762 0.16 0.19 2.29 73 -2.27 1.80 73 -0.2 122 0.090 102 108 20.5 -0.2 636 138 170 219 227 278 552 87 64 83 71 73 -0.062 10.93 0.72

69 11.266 11.935 0.16 0.17 2.26 74 -2 1.76 73 0.1 122 0.090 100 100 20.3 -0.2 665 137 170 221 229 284 575 87 64 83 71 73 -0.064 13.05 0.88

70 11.430 12.108 0.16 0.17 2.27 74 -1.89 1.95 73 -0.1 123 0.090 101 100 20.0 -0.3 691 137 171 222 231 290 586 87 64 85 72 73 -0.065 13.22 0.81

71 11.594 12.280 0.16 0.17 2.27 74 -2.26 1.75 73 -0.2 124 0.090 101 99 19.7 -0.3 710 137 171 223 232 295 588 87 64 86 71 73 -0.066 12.89 0.79

72 11.757 12.455 0.16 0.18 2.27 74 -2.22 1.85 74 -0.2 124 0.090 101 101 19.5 -0.2 729 138 170 224 234 299 594 87 64 87 71 73 -0.068 12.99 0.64

73 11.920 12.632 0.16 0.18 2.26 74 -1.93 1.84 74 -0.2 124 0.090 101 102 19.3 -0.2 749 138 170 225 236 304 595 87 64 88 71 73 -0.067 12.82 0.57

Control No. P-SSAR-0003 Page 6 of 12 High Burn Run 5

88 of 190

_______________________________

Page 89: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.01 ft/sec.2408 174 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 223.8 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.3 scfm30-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.29 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP 0.090 0.090 0.092 0.074 0.086 0.090 0.096 0.080 0.094 "H2O

OMNI Equipment Numbers: Temp: 71 71 71 71 71 71 71 71 71 °FVstrav 19.83 ft/sec Vscent 20.51 ft/sec Fp 0.967

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

74 12.084 12.809 0.16 0.18 2.26 74 -2.28 1.84 74 -0.1 126 0.080 108 108 19.0 -0.3 764 139 170 226 237 307 601 87 64 88 72 73 -0.069 13.1 0.55

75 12.248 12.985 0.16 0.18 2.26 74 -1.85 1.84 74 -0.1 127 0.090 102 102 18.8 -0.2 776 139 169 226 239 310 606 87 64 87 71 73 -0.068 13.69 0.47

76 12.411 13.162 0.16 0.18 2.26 74 -2.02 1.84 74 0.1 127 0.090 101 102 18.5 -0.3 780 140 169 228 240 311 602 87 64 87 72 73 -0.069 13.6 0.4

77 12.574 13.338 0.16 0.18 2.25 74 -2.07 1.84 74 0 127 0.080 107 108 18.2 -0.3 782 141 168 229 242 312 596 86 64 86 72 73 -0.068 13.11 0.33

78 12.738 13.515 0.16 0.18 2.26 74 -1.97 1.83 74 -0.2 126 0.080 108 108 18.0 -0.2 785 141 168 230 243 313 589 86 64 86 72 73 -0.068 13.45 0.35

79 12.900 13.691 0.16 0.18 2.25 74 -2.04 1.84 74 -0.3 126 0.080 106 108 17.7 -0.3 789 142 167 231 245 315 584 86 64 86 72 73 -0.067 12.92 0.3

80 13.064 13.867 0.16 0.18 2.25 74 -2.11 1.84 74 -0.2 126 0.080 108 108 17.6 -0.1 796 142 167 233 246 317 590 86 65 86 72 73 -0.068 12.91 0.35

81 13.228 14.044 0.16 0.18 2.26 74 -2.28 1.84 74 -0.2 127 0.080 108 108 17.3 -0.3 803 143 167 235 248 319 597 86 65 86 72 73 -0.068 13.46 0.38

82 13.391 14.221 0.16 0.18 2.25 74 -1.87 1.83 74 -0.2 127 0.080 107 108 17.0 -0.3 806 143 167 236 249 320 597 86 65 86 72 73 -0.069 13.69 0.35

83 13.554 14.397 0.16 0.18 2.26 74 -1.88 1.84 74 0.1 127 0.080 107 108 16.7 -0.3 805 144 167 238 251 321 592 87 65 86 72 74 -0.067 13.57 0.3

84 13.717 14.574 0.16 0.18 2.26 74 -1.79 1.84 74 -0.1 126 0.080 107 108 16.5 -0.2 805 145 167 241 252 322 587 86 65 86 72 74 -0.066 13.36 0.25

85 13.880 14.750 0.16 0.18 2.25 74 -1.8 1.84 74 0 126 0.080 107 108 16.3 -0.2 808 145 166 243 253 323 579 86 65 86 72 73 -0.067 12.79 0.24

86 14.044 14.927 0.16 0.18 2.25 74 -1.87 1.84 74 -0.3 125 0.080 108 108 16.2 -0.1 809 145 167 245 255 324 577 86 65 86 72 74 -0.067 12.52 0.25

87 14.208 15.104 0.16 0.18 2.25 74 -2.16 1.84 74 -0.2 126 0.080 108 108 16.0 -0.2 810 146 167 247 256 325 578 86 65 86 72 73 -0.067 12.69 0.25

88 14.370 15.280 0.16 0.18 2.24 75 -2.25 1.84 75 -0.1 126 0.090 100 101 15.8 -0.2 808 147 167 250 258 326 586 87 65 86 73 74 -0.067 12.87 0.3

89 14.534 15.457 0.16 0.18 2.26 75 -2.23 1.83 75 -0.3 127 0.080 107 108 15.6 -0.2 809 148 167 252 259 327 588 87 65 86 73 74 -0.067 13.43 0.42

90 14.697 15.633 0.16 0.18 2.26 75 -1.98 1.84 75 0.1 126 0.090 101 101 15.3 -0.3 812 149 168 254 260 329 584 87 65 86 73 74 -0.066 13.3 0.39

91 14.860 15.810 0.16 0.18 2.25 75 -2.27 1.83 75 -0.1 126 0.090 101 102 15.0 -0.3 811 149 168 257 262 329 583 87 65 87 73 73 -0.066 13.21 0.35

92 15.023 15.987 0.16 0.18 2.25 75 -2.24 1.84 75 -0.3 126 0.090 101 102 14.7 -0.3 808 150 169 259 264 330 579 87 65 87 73 74 -0.067 13.16 0.38

93 15.187 16.163 0.16 0.18 2.24 75 -1.81 1.84 75 -0.2 126 0.090 101 101 14.5 -0.2 807 151 170 261 266 331 581 87 66 87 72 74 -0.065 13.19 0.34

94 15.350 16.339 0.16 0.18 2.24 75 -2.3 1.84 75 -0.2 125 0.090 101 101 14.2 -0.3 805 151 170 264 268 332 578 87 66 87 72 74 -0.066 12.95 0.3

95 15.513 16.516 0.16 0.18 2.25 75 -2.09 1.82 75 -0.2 125 0.090 101 102 13.9 -0.3 806 152 171 266 270 333 578 87 66 87 73 75 -0.065 13.01 0.3

96 15.676 16.693 0.16 0.18 2.23 75 -2.29 1.84 75 -0.2 125 0.080 107 108 13.8 -0.1 809 153 172 268 272 335 577 87 66 87 72 74 -0.065 12.95 0.28

97 15.839 16.869 0.16 0.18 2.24 75 -1.95 1.83 75 -0.3 125 0.090 101 101 13.6 -0.2 806 154 172 270 275 335 578 87 66 87 73 74 -0.065 12.67 0.28

98 16.002 17.046 0.16 0.18 2.24 75 -2.23 1.84 75 -0.1 125 0.090 101 102 13.5 -0.1 806 156 173 272 277 337 574 87 66 87 73 74 -0.065 12.64 0.27

99 16.166 17.223 0.16 0.18 2.23 75 -2.26 1.84 75 -0.1 125 0.090 101 102 13.2 -0.3 805 156 174 274 280 338 570 87 66 87 73 73 -0.065 12.48 0.27

100 16.328 17.400 0.16 0.18 2.24 75 -1.88 1.84 75 -0.3 124 0.090 100 102 13.0 -0.2 807 157 175 276 282 339 565 87 66 87 73 74 -0.064 12.31 0.29

101 16.491 17.576 0.16 0.18 2.24 75 -1.81 1.84 75 -0.1 124 0.090 100 101 12.8 -0.2 807 158 176 278 284 341 561 87 66 87 73 74 -0.063 12.16 0.26

102 16.655 17.753 0.16 0.18 2.24 75 -1.9 1.83 75 -0.2 123 0.090 101 102 12.6 -0.2 806 159 177 279 286 341 560 87 66 87 73 74 -0.064 11.96 0.27

103 16.818 17.929 0.16 0.18 2.23 75 -1.94 1.84 75 0.1 123 0.090 100 101 12.4 -0.2 805 159 177 281 289 342 557 87 66 87 73 74 -0.064 12.02 0.23

104 16.981 18.107 0.16 0.18 2.26 75 -2.23 1.84 75 -0.1 123 0.090 100 102 12.2 -0.2 802 159 179 283 290 343 555 87 66 87 73 74 -0.063 11.82 0.25

105 17.145 18.283 0.16 0.18 2.25 75 -2 1.82 76 0 123 0.090 101 101 12.0 -0.2 801 161 179 284 292 343 553 87 66 87 73 74 -0.063 11.71 0.28

106 17.307 18.460 0.16 0.18 2.23 75 -1.8 1.84 76 -0.3 123 0.090 100 101 11.7 -0.3 800 160 181 286 294 344 553 87 66 87 73 75 -0.063 11.7 0.3

107 17.471 18.637 0.16 0.18 2.25 75 -1.98 1.84 76 0 122 0.090 101 101 11.5 -0.2 799 160 182 287 295 345 551 87 66 87 73 75 -0.064 11.59 0.29

108 17.634 18.813 0.16 0.18 2.24 75 -2.28 1.84 76 -0.3 122 0.090 100 101 11.4 -0.1 797 161 183 288 297 345 548 87 66 87 73 75 -0.063 11.42 0.31

109 17.797 18.990 0.16 0.18 2.23 75 -2.26 1.83 76 0 122 0.090 100 101 11.2 -0.2 795 162 184 289 298 346 547 88 66 87 73 75 -0.063 11.4 0.34

110 17.960 19.167 0.16 0.18 2.24 75 -2.06 1.84 76 -0.1 121 0.090 100 101 11.0 -0.2 792 162 185 291 300 346 544 88 66 87 73 75 -0.063 11.46 0.31

Control No. P-SSAR-0003 Page 7 of 12 High Burn Run 5

89 of 190

re:________________________________________________ ___

Page 90: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.01 ft/sec.2408 174 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 223.8 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.3 scfm30-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.29 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP 0.090 0.090 0.092 0.074 0.086 0.090 0.096 0.080 0.094 "H2O

OMNI Equipment Numbers: Temp: 71 71 71 71 71 71 71 71 71 °FVstrav 19.83 ft/sec Vscent 20.51 ft/sec Fp 0.967

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

111 18.124 19.343 0.16 0.18 2.25 75 -1.86 1.84 76 -0.1 121 0.090 101 101 10.8 -0.2 789 163 186 291 301 346 543 88 66 87 73 75 -0.063 11.39 0.33

112 18.287 19.520 0.16 0.18 2.23 75 -2.25 1.83 76 0 121 0.090 100 101 10.7 -0.1 786 164 188 292 302 346 543 88 66 87 73 75 -0.063 11.4 0.33

113 18.450 19.697 0.16 0.18 2.25 76 -2.24 1.82 76 -0.3 121 0.090 100 101 10.5 -0.2 785 165 189 293 303 347 543 88 66 87 73 75 -0.063 11.4 0.36

114 18.614 19.874 0.16 0.18 2.25 76 -2.28 1.84 76 -0.2 121 0.090 101 101 10.3 -0.2 784 166 190 294 305 348 541 88 66 87 73 75 -0.063 11.52 0.35

115 18.776 20.051 0.16 0.18 2.24 76 -1.83 1.84 76 -0.3 121 0.090 99 101 10.1 -0.2 784 166 191 295 306 348 543 88 66 87 73 75 -0.063 11.65 0.34

116 18.939 20.228 0.16 0.18 2.25 76 -1.86 1.84 76 -0.2 121 0.090 100 101 10.0 -0.1 779 166 192 296 307 348 543 87 66 86 73 75 -0.063 11.84 0.32

117 19.103 20.405 0.16 0.18 2.25 76 -2.29 1.84 76 0 121 0.090 101 101 9.8 -0.2 777 167 193 297 308 348 546 87 66 85 73 75 -0.062 12.11 0.29

118 19.266 20.582 0.16 0.18 2.24 76 -1.82 1.85 76 -0.2 121 0.090 100 101 9.6 -0.2 777 167 195 298 309 349 547 87 66 85 73 75 -0.062 12.2 0.28

119 19.429 20.759 0.16 0.18 2.25 76 -2.05 1.85 76 -0.3 121 0.090 100 101 9.5 -0.1 775 168 196 299 310 350 547 87 66 85 73 75 -0.062 12.37 0.24

120 19.593 20.936 0.16 0.18 2.25 76 -1.9 1.84 76 -0.3 121 0.090 101 101 9.3 -0.2 777 169 198 301 311 351 545 87 66 85 73 75 -0.063 12.41 0.24

121 19.755 21.113 0.16 0.18 2.24 76 -1.81 1.84 76 -0.1 121 0.090 99 101 9.1 -0.2 777 169 199 302 313 352 547 87 66 85 73 75 -0.062 12.42 0.23

122 19.918 21.290 0.16 0.18 2.25 76 -1.86 1.84 76 0 121 0.090 100 101 8.9 -0.2 778 169 201 303 314 353 547 87 66 85 73 75 -0.062 12.51 0.22

123 20.082 21.467 0.16 0.18 2.24 76 -2.24 1.85 77 -0.3 121 0.090 101 101 8.7 -0.2 783 170 203 305 316 355 547 87 66 85 73 76 -0.063 12.51 0.22

124 20.245 21.644 0.16 0.18 2.22 76 -1.83 1.84 77 -0.1 121 0.090 100 101 8.4 -0.3 781 171 204 306 317 356 546 87 66 85 73 75 -0.062 12.39 0.21

125 20.408 21.821 0.16 0.18 2.24 76 -2.19 1.84 77 0 121 0.090 100 101 8.3 -0.1 780 171 206 307 318 356 544 87 66 85 73 75 -0.062 12.25 0.2

126 20.571 21.997 0.16 0.18 2.23 76 -2.02 1.84 77 -0.1 121 0.090 100 100 8.1 -0.2 779 171 208 308 320 357 542 87 67 85 73 75 -0.061 12.14 0.21

127 20.734 22.175 0.16 0.18 2.22 76 -1.92 1.84 77 -0.3 120 0.080 106 108 7.9 -0.2 782 172 210 309 321 359 539 87 67 85 73 75 -0.061 12.03 0.2

128 20.897 22.351 0.16 0.18 2.24 76 -2.19 1.84 77 -0.2 120 0.090 100 100 7.8 -0.1 780 173 212 311 323 360 538 87 67 86 74 76 -0.061 11.91 0.2

129 21.060 22.529 0.16 0.18 2.24 76 -1.82 1.83 77 0 120 0.090 100 102 7.6 -0.2 778 174 213 311 324 360 537 87 67 86 74 75 -0.061 11.78 0.2

130 21.223 22.705 0.16 0.18 2.23 76 -2 1.83 77 -0.2 120 0.090 100 100 7.5 -0.1 780 175 216 312 325 362 536 87 67 86 74 75 -0.060 11.8 0.19

131 21.386 22.882 0.16 0.18 2.24 76 -1.82 1.84 77 0 120 0.090 100 101 7.3 -0.2 779 175 217 313 326 362 535 87 67 86 74 75 -0.061 11.68 0.18

132 21.550 23.059 0.16 0.18 2.24 76 -2.31 1.84 77 -0.3 119 0.090 100 101 7.1 -0.2 780 176 219 314 327 363 534 87 67 86 74 75 -0.061 11.71 0.19

133 21.712 23.235 0.16 0.18 2.23 76 -1.82 1.83 77 0 119 0.090 99 100 6.9 -0.2 779 176 221 315 328 364 531 87 67 86 74 75 -0.061 11.67 0.18

134 21.875 23.413 0.16 0.18 2.24 76 -2.28 1.84 77 -0.1 119 0.090 100 101 6.8 -0.1 779 176 223 315 329 364 531 87 67 86 73 75 -0.060 11.76 0.17

135 22.039 23.589 0.16 0.18 2.24 76 -2.18 1.84 77 -0.3 119 0.090 100 100 6.7 -0.1 778 177 225 316 330 365 532 87 67 86 73 75 -0.060 11.77 0.16

136 22.202 23.766 0.16 0.18 2.23 76 -2.31 1.84 77 0 119 0.090 100 101 6.5 -0.2 777 177 227 317 330 366 532 88 67 86 73 75 -0.060 11.68 0.17

137 22.365 23.943 0.16 0.18 2.24 76 -2.31 1.83 77 0 119 0.090 100 101 6.4 -0.1 777 178 229 318 331 367 530 87 67 86 73 75 -0.059 11.64 0.16

138 22.529 24.120 0.16 0.18 2.25 76 -2.27 1.84 77 0 118 0.090 100 101 6.2 -0.2 777 178 230 319 332 367 528 88 67 86 73 75 -0.059 11.54 0.16

139 22.691 24.297 0.16 0.18 2.23 76 -2.17 1.84 77 0 119 0.090 99 101 6.1 -0.1 776 179 233 319 332 368 527 88 67 86 73 75 -0.058 11.49 0.16

140 22.854 24.473 0.16 0.18 2.25 76 -2.25 1.83 77 0 119 0.090 100 100 5.9 -0.2 774 179 235 320 333 368 525 88 67 86 73 76 -0.058 11.44 0.17

141 23.017 24.650 0.16 0.18 2.22 77 -2.02 1.83 77 -0.3 118 0.090 100 101 5.8 -0.1 772 179 236 321 333 368 520 88 67 86 73 75 -0.058 11.4 0.17

142 23.180 24.826 0.16 0.18 2.24 77 -2.31 1.83 77 -0.2 118 0.090 100 100 5.6 -0.2 769 180 238 322 334 369 520 88 67 86 73 75 -0.058 11.26 0.18

143 23.343 25.003 0.16 0.18 2.24 77 -2.16 1.83 77 0 117 0.090 99 101 5.5 -0.1 766 180 240 322 335 369 518 88 67 86 73 75 -0.057 11.16 0.2

144 23.507 25.180 0.16 0.18 2.23 77 -2.3 1.83 77 0 117 0.090 100 101 5.3 -0.2 766 180 242 323 335 369 514 88 67 86 73 75 -0.058 11 0.2

145 23.669 25.357 0.16 0.18 2.23 77 -2.19 1.82 77 -0.1 117 0.090 99 101 5.2 -0.1 764 181 243 323 336 369 515 88 67 86 73 75 -0.058 10.92 0.2

146 23.832 25.533 0.16 0.18 2.24 77 -2.25 1.84 77 0 116 0.090 99 100 5.1 -0.1 760 181 245 324 336 369 512 88 67 86 73 74 -0.058 10.8 0.21

147 23.996 25.710 0.16 0.18 2.24 77 -2.32 1.84 77 0 116 0.090 100 101 5.0 -0.1 758 181 246 324 337 369 509 88 67 86 73 76 -0.058 10.69 0.22

Control No. P-SSAR-0003 Page 8 of 12 High Burn Run 5

90 of 190

e:________________________________

Page 91: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.01 ft/sec.2408 174 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 223.8 scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 211.3 scfm30-Apr-20 Dilution Tunnel Static: -0.194 "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ 14 in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 20.29 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP 0.090 0.090 0.092 0.074 0.086 0.090 0.096 0.080 0.094 "H2O

OMNI Equipment Numbers: Temp: 71 71 71 71 71 71 71 71 71 °FVstrav 19.83 ft/sec Vscent 20.51 ft/sec Fp 0.967

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

148 24.158 25.887 0.16 0.18 2.23 77 -2.07 1.81 77 0 116 0.090 99 101 4.8 -0.2 755 181 248 325 338 369 507 88 67 86 73 76 -0.056 10.57 0.24

149 24.322 26.064 0.16 0.18 2.24 77 -2.23 1.84 77 0 116 0.090 100 101 4.7 -0.1 754 182 249 325 339 370 506 88 67 86 73 76 -0.057 10.58 0.25

150 24.485 26.241 0.16 0.18 2.24 77 -2.08 1.83 77 -0.2 115 0.090 99 101 4.5 -0.2 751 183 250 325 339 370 506 88 67 86 73 76 -0.056 10.53 0.26

151 24.648 26.417 0.16 0.18 2.23 77 -1.97 1.84 77 0 116 0.090 99 100 4.4 -0.1 751 183 252 325 340 370 506 88 67 86 73 75 -0.058 10.45 0.26

152 24.811 26.594 0.16 0.18 2.24 77 -2.32 1.83 78 -0.1 115 0.090 99 100 4.3 -0.1 750 183 253 325 340 370 502 88 67 86 73 76 -0.058 10.44 0.26

153 24.974 26.771 0.16 0.18 2.23 77 -2.26 1.83 78 -0.3 115 0.090 99 100 4.2 -0.1 745 184 254 325 340 370 502 88 67 86 74 76 -0.058 10.13 0.36

154 25.137 26.948 0.16 0.18 2.23 77 -2.05 1.83 78 -0.3 115 0.090 99 100 4.1 -0.1 742 184 256 325 341 370 501 88 67 86 74 76 -0.057 10.08 0.36

155 25.300 27.124 0.16 0.18 2.24 77 -1.98 1.83 78 -0.2 115 0.090 99 100 4.0 -0.1 739 184 257 325 341 369 500 88 67 86 74 76 -0.057 10 0.39

156 25.464 27.301 0.16 0.18 2.24 77 -1.95 1.84 78 0 114 0.090 100 100 3.9 -0.1 738 185 258 325 342 370 499 88 67 86 74 75 -0.057 9.94 0.37

157 25.626 27.478 0.16 0.18 2.23 77 -1.89 1.83 78 -0.1 114 0.090 99 100 3.8 -0.1 733 186 259 324 343 369 495 88 67 86 73 75 -0.057 9.84 0.38

158 25.789 27.655 0.16 0.18 2.22 77 -1.95 1.83 78 -0.3 114 0.090 99 100 3.6 -0.2 732 186 261 324 343 369 495 88 67 86 74 75 -0.057 9.81 0.4

159 25.952 27.832 0.16 0.18 2.23 77 -2.29 1.83 78 0 114 0.090 99 100 3.5 -0.1 732 186 262 323 344 369 496 88 67 86 74 76 -0.057 9.95 0.34

160 26.115 28.008 0.16 0.18 2.23 77 -2.3 1.83 78 0 114 0.090 99 100 3.4 -0.1 733 187 263 323 344 370 494 88 67 86 74 75 -0.057 9.9 0.35

161 26.278 28.185 0.16 0.18 2.24 77 -2.23 1.84 78 -0.3 114 0.090 99 100 3.3 -0.1 733 186 264 322 345 370 496 88 67 86 74 75 -0.057 9.96 0.33

162 26.441 28.362 0.16 0.18 2.23 77 -1.9 1.83 78 0 114 0.090 99 100 3.2 -0.1 733 187 265 322 346 371 494 88 67 86 74 76 -0.057 9.93 0.31

163 26.604 28.539 0.16 0.18 2.23 77 -2.17 1.83 78 0 113 0.090 99 100 3.1 -0.1 733 187 267 321 347 371 493 88 67 86 74 75 -0.057 9.87 0.31

164 26.767 28.716 0.16 0.18 2.24 77 -2.31 1.84 78 -0.1 113 0.090 99 100 3.0 -0.1 732 188 268 321 348 371 491 89 67 86 74 75 -0.057 9.83 0.33

165 26.930 28.893 0.16 0.18 2.24 77 -1.89 1.83 78 -0.2 113 0.090 99 100 2.9 -0.1 731 188 270 320 348 371 490 89 67 86 74 75 -0.056 9.78 0.34

166 27.092 29.069 0.16 0.18 2.24 77 -2.06 1.84 78 -0.3 112 0.090 98 99 2.8 -0.1 731 188 271 320 349 372 486 89 67 86 74 75 -0.056 9.77 0.33

167 27.255 29.247 0.16 0.18 2.24 77 -1.84 1.83 78 -0.1 112 0.090 99 101 2.7 -0.1 729 189 272 319 350 372 486 89 67 86 74 75 -0.056 9.74 0.36

168 27.419 29.424 0.16 0.18 2.24 77 -2.28 1.83 78 -0.3 112 0.090 100 100 2.6 -0.1 728 189 274 319 350 372 485 89 67 86 74 75 -0.056 9.73 0.37

169 27.581 29.600 0.16 0.18 2.23 77 -2.08 1.83 78 0 112 0.090 98 99 2.5 -0.1 727 189 275 318 351 372 486 89 67 86 74 75 -0.055 9.7 0.36

170 27.744 29.777 0.16 0.18 2.24 77 -1.98 1.83 78 0 112 0.090 99 100 2.4 -0.1 726 190 276 318 351 372 483 89 67 86 74 75 -0.055 9.68 0.38

171 27.907 29.954 0.16 0.18 2.22 77 -2.24 1.83 78 -0.1 112 0.090 99 100 2.4 0 723 190 277 317 352 372 482 89 67 86 74 74 -0.055 9.7 0.39

172 28.070 30.131 0.16 0.18 2.23 77 -1.83 1.83 78 0 111 0.090 99 100 2.3 -0.1 721 190 278 317 353 372 480 89 67 86 74 74 -0.055 9.58 0.4

173 28.233 30.308 0.16 0.18 2.24 77 -2.05 1.84 78 -0.3 111 0.090 99 100 2.2 -0.1 718 191 280 316 353 372 478 89 67 86 74 74 -0.055 9.64 0.38

174 28.396 30.485 0.16 0.18 2.22 77 -2.3 1.84 78 -0.2 111 0.090 99 100 2.1 -0.1 715 191 281 316 353 371 475 89 67 86 74 75 -0.055 9.68 0.38Avg/Tot 28.396 30.485 0.16 0.18 2.25 74 1.81 74 110 0.089 100 100 300.0 65 85 71 73 -0.055

Control No. P-SSAR-0003 Page 9 of 12 High Burn Run 5

91 of 190

e:___________ ___________________________________________________________________________________________ _______________

Page 92: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis Industries Equipment Numbers: Model: Medium Flush Wood

Tracking No.: 2408Project No.: 0028WN123E

Run #: 5Date: 4/30/20

TRAIN 1 (First Hour emissions)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mgB. Front filter catch Filter T242S 102.0 99.4 2.6C. Rear filter catch Filter 0.0D. Probe catch* Probe 0.0E. Filter seals catch* Seals 0.0

Sub-Total Total Particulate, mg: 2.6

TRAIN 1 (Post First Hour Change-out)Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mgB. Front filter catch Filter T231AP 201.1 198.0 3.1C. Rear filter catch Filter 0.0D. Probe catch* Probe 30 114329.1 114327.5 1.6E. Filter seals catch* Seals R970 3312.9 3312.5 0.4

Sub-Total Total Particulate, mg: 5.1

Train 1 Aggregate Total Particulate, mg: 7.7

TRAIN 2Sample Component Reagent Filter, Probe Weights

or Dish # Final, mg Tare, mg Particulate, mgA. Front filter catch Filter T231BP 202.2 198.4 3.8B. Rear filter catch Filter T243S 99.5 97.9 1.6C. Probe catch* Probe 31 114366.1 114364.8 1.3D. Filter seals catch* Seals R971 3261.3 3261.2 0.1

Total Particulate, mg: 6.8

AMBIENTSample Component Reagent Filter # or Weights

Probe # Final, mg Tare, mg Particulate, mgA. Front filter catch* Filter 0.0

Total Particulate, mg: 0.0

Component Equations:A. Front filter catch Final (mg) - Tare (mg) = Particulate, mgB. Rear filter catch Final (mg) - Tare (mg) = Particulate, mgC. Probe catch Final (mg) - Tare (mg) = Particulate, mg

Technician Signature:_____________________________________________________

*Particulate catch that results in a negative number, is assumed to be zero forprobes and seals, negative numbers for filters are assumed to be part of the sealweight.

Wood Heater Lab Data - ASTM E3053 / ASTM E2515

Control No. P-SSAR-0003 High Burn Run 592 of 190

_____________________________________________ _____________________________________

Page 93: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN123ETracking No.: 2408

Run: 5Test Date:

Burn Rate 3.35 kg/hr dry

Average Tunnel Temperature 110 degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs 20.01 feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd 12678.0 dscf/hour

Average Delta p 0.089 inches H20Total Time of Test 174 minutes

Total Sample Volume - Vm 0.000 cubic feet 28.396 cubic feet 30.485 cubic feet 9.790 cubic feetAverage Gas Meter Temperature 73 degrees Fahrenheit 74 degrees Fahrenheit 74 degrees Fahrenheit 72 degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd 0.000 dscf 27.547 dscf 29.439 dscf 9.542 dscf

Total Particulates - mn 0 mg 7.7 mg 6.8 mg 2.6 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf 0.00028 grams/dscf 0.00023 grams/dscf 0.00027 grams/dscfTotal Particulate Emissions - ET 0.00 grams 10.28 grams 8.49 grams 3.45 gramsParticulate Emission Rate 0.00 grams/hour 3.54 grams/hour 2.93 grams/hour 3.45 grams/hourEmissions Factor 1.06 g/kg 0.87 g/kg 1.33 g/kg

Difference from Average Total Particulate Emissions 0.89 grams 0.89 grams

Complete Test RunTotal Particulate Emissions - ET 9.38 gramsParticulate Emission Rate 3.24 grams/hourEmissions Factor 0.97 grams/kg

First Hour EmissionsTotal Particulate Emissions - ET 3.45 gramsParticulate Emission Rate 3.45 grams/hourEmissions Factor 1.33 grams/kg

7.5% of Average Total Particulate Emissions 0.70 grams

Technician Signature:_____________________________________________________

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/30/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

Dual Train Comparison Results Are Acceptable

Filter Temps < 90 °F OKOKOKOK

Stove Surface ∆T NOT ACCEPTABLE

OK

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.OKPro-Rate Variation OK

Control No. P-SSAR-0003 High Burn Run 593 of 190

_________________________ ______________

Page 94: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 VersionCordwood Fuel Load Calculators 10 lb/ft3 Nominal Load DensityCore 45 65% of Total Load Weight, Remainder 35 55% of Total Load Weight

Values to be input manuallyFor All Usable Firebox Volumes High Fire Test OnlyNominal Required Load Density (wet basis) 10 lb/ft3

Usable Firebox Volume 2.20 ft3

Total Nom. Load Wt. Target 22.00 lbTotal Load Wt. Allowable Range 20.90 to 23.10 lbCore Target Wt. Allowable Range 9.90 to 14.30 lbRemainder Load Wt. Allowable Range 7.70 to 12.10 lb

Mid PointCore Load Pc. Wt. Allowable Range 3.30 to 5.50 lb 4.40Remainder Load Pc. Wt. Allowable Range 2.20 to 12.10 lb 7.15 Fuel Piece Moisture Reading (% dry basis)

Pc. # 1 2 3 Ave.Core Load Piece Wt. Actual 1 4.72 lb In Range 19.1 18.8 19.7 19.2 In Range 3.96 lb 1.79 kg

2 4.26 lb In Range 21.9 20.6 21.7 21.4 In Range 3.50 lb 1.59 kg3 4.22 lb In Range 23.8 22.6 21.9 22.8 In Range 3.44 lb 1.56 kg

Core Load Total. Wt. Actual 13.19 lb In RangePc. #

Remainder Load Piece Wt. 1 4.87 lb In Range 24.2 23.2 23.8 23.7 In Range 3.93 lb 1.78 kg(1 to 3 Pcs.) 2 3.72 lb In Range 22.2 20.5 23.2 22.0 In Range 3.05 lb 1.38 kg

3 lb NA NA NA NA lb NA kgRemainder Load Tot. Wt. Act 8.58 lb In Range Total Load Ave. MC (% dry basis) 21.8 In RangeTotal Load Wt. Actual 21.77 lb In Range Total Load Ave. MC % (wet basis) 17.9Core % of Total Wt. 61% In Range 45 65% Total Test Load Weight (dry basis) 17.88 lb 8.11 kgRemainder % of Total Wt. 39% In Range 35 55%Actual Load % of Nominal Target 99% In Range 95 105% Kindling Moisture (% dry basis)Actual Fuel Load Density 9.9 lb/ft3 9.9 8.8 9.5 9.4 In Range 3.93 lb 1.78 kgKindling and Start up Fuel Start up Fuel Moisture Readings (% dry basis)Maximim Kindling Wt. (20% of Tot. Load Wt.) 4.35 lb 22.8 24.6 23.3 23.6 In Range 5.02 lb 2.28 kgActual Kindling Wt. 4.30 lb In Range 19.8%Maximum Start up Fuel Wt. (30% of Tot. Load Wt.) 6.53 lb Total Wt. All Fuel Added (dry basis) 26.82 lb 12.17 kgActual Start up Fuel Wt. 6.20 lb In Range 28.5% Total Wt. All Fuel Burned (dry basis) 21.4 lb 9.7 kgAllowable Residual Start up Fuel Wt. Range 2.2 to 4.4 lb Mid PointActual Residual Start up Fuel Wt. 3.3 lb In Range 3.3Total Wt. All Fuel Added (wet basis) 32.27 lbHigh Fire Test Run End Point Range Low High Mid PointBased on Fuel Load Wt. (w/tares) 2.0 to 2.4 lb 2.2Actual Fuel Load Ending Wt. 2.1 lb In Range

Pc. Wt. Dry Basis

THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING JURISDICTION AND THE PRESIDENT OF THE SOCIETY. COPYRIGHT ASTM, 100 BARR HARBOR DRIVE, WEST CONSHOHOCKEN, PA 19428. ALL RIGHTS RESERVED.

94 of 190

Page 95: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

95 of 190

Page 96: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

96 of 190

Page 97: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Run 5

High Burn 1-minute data

Efficiency and Heat Output Results Kindling and start-up fuel removed from calculations

97 of 190

Page 98: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 110 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: #DIV/0! scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm30-Apr-20 Dilution Tunnel Static: "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.81 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP "H2O

OMNI Equipment Numbers: Temp: °FVstrav ft/sec Vscent ft/sec Fp

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

0 19.7 562 134 164 213 219 258 451 86 64 83 71 72 -0.058 7.37 0.33

1 19.2 -0.5 548 134 166 215 221 257 459 87 64 83 71 73 -0.064 2.42 0.23

2 19.0 -0.2 576 134 168 217 223 264 575 87 64 84 71 73 -0.061 7.05 0.37

3 18.6 -0.4 609 136 169 218 225 271 526 87 64 84 71 73 -0.060 10.49 0.58

4 18.4 -0.2 636 138 170 219 227 278 552 87 64 83 71 73 -0.062 10.93 0.72

5 18.2 -0.2 665 137 170 221 229 284 575 87 64 83 71 73 -0.064 13.05 0.88

6 17.9 -0.3 691 137 171 222 231 290 586 87 64 85 72 73 -0.065 13.22 0.81

7 17.6 -0.3 710 137 171 223 232 295 588 87 64 86 71 73 -0.066 12.89 0.79

8 17.4 -0.2 729 138 170 224 234 299 594 87 64 87 71 73 -0.068 12.99 0.64

9 17.2 -0.2 749 138 170 225 236 304 595 87 64 88 71 73 -0.067 12.82 0.57

10 16.9 -0.3 764 139 170 226 237 307 601 87 64 88 72 73 -0.069 13.1 0.55

11 16.7 -0.2 776 139 169 226 239 310 606 87 64 87 71 73 -0.068 13.69 0.47

12 16.4 -0.3 780 140 169 228 240 311 602 87 64 87 72 73 -0.069 13.6 0.4

13 16.1 -0.3 782 141 168 229 242 312 596 86 64 86 72 73 -0.068 13.11 0.33

14 15.9 -0.2 785 141 168 230 243 313 589 86 64 86 72 73 -0.068 13.45 0.35

15 15.6 -0.3 789 142 167 231 245 315 584 86 64 86 72 73 -0.067 12.92 0.3

16 15.5 -0.1 796 142 167 233 246 317 590 86 65 86 72 73 -0.068 12.91 0.35

17 15.2 -0.3 803 143 167 235 248 319 597 86 65 86 72 73 -0.068 13.46 0.38

18 14.9 -0.3 806 143 167 236 249 320 597 86 65 86 72 73 -0.069 13.69 0.35

19 14.6 -0.3 805 144 167 238 251 321 592 87 65 86 72 74 -0.067 13.57 0.3

20 14.4 -0.2 805 145 167 241 252 322 587 86 65 86 72 74 -0.066 13.36 0.25

21 14.2 -0.2 808 145 166 243 253 323 579 86 65 86 72 73 -0.067 12.79 0.24

22 14.1 -0.1 809 145 167 245 255 324 577 86 65 86 72 74 -0.067 12.52 0.25

23 13.9 -0.2 810 146 167 247 256 325 578 86 65 86 72 73 -0.067 12.69 0.25

24 13.7 -0.2 808 147 167 250 258 326 586 87 65 86 73 74 -0.067 12.87 0.3

25 13.5 -0.2 809 148 167 252 259 327 588 87 65 86 73 74 -0.067 13.43 0.42

26 13.2 -0.3 812 149 168 254 260 329 584 87 65 86 73 74 -0.066 13.3 0.39

27 12.9 -0.3 811 149 168 257 262 329 583 87 65 87 73 73 -0.066 13.21 0.35

28 12.6 -0.3 808 150 169 259 264 330 579 87 65 87 73 74 -0.067 13.16 0.38

29 12.4 -0.2 807 151 170 261 266 331 581 87 66 87 72 74 -0.065 13.19 0.34

30 12.1 -0.3 805 151 170 264 268 332 578 87 66 87 72 74 -0.066 12.95 0.3

31 11.8 -0.3 806 152 171 266 270 333 578 87 66 87 73 75 -0.065 13.01 0.3

32 11.7 -0.1 809 153 172 268 272 335 577 87 66 87 72 74 -0.065 12.95 0.28

33 11.5 -0.2 806 154 172 270 275 335 578 87 66 87 73 74 -0.065 12.67 0.28

34 11.4 -0.1 806 156 173 272 277 337 574 87 66 87 73 74 -0.065 12.64 0.27

35 11.1 -0.3 805 156 174 274 280 338 570 87 66 87 73 73 -0.065 12.48 0.27

36 10.9 -0.2 807 157 175 276 282 339 565 87 66 87 73 74 -0.064 12.31 0.29

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Control No. P-SSAR-0003 Page 5 of 11 High Burn Run 5_Efficiency

98 of 190

re:____________________________

Page 99: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 110 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: #DIV/0! scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm30-Apr-20 Dilution Tunnel Static: "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.81 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP "H2O

OMNI Equipment Numbers: Temp: °FVstrav ft/sec Vscent ft/sec Fp

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

37 10.7 -0.2 807 158 176 278 284 341 561 87 66 87 73 74 -0.063 12.16 0.26

38 10.5 -0.2 806 159 177 279 286 341 560 87 66 87 73 74 -0.064 11.96 0.27

39 10.3 -0.2 805 159 177 281 289 342 557 87 66 87 73 74 -0.064 12.02 0.23

40 10.1 -0.2 802 159 179 283 290 343 555 87 66 87 73 74 -0.063 11.82 0.25

41 9.9 -0.2 801 161 179 284 292 343 553 87 66 87 73 74 -0.063 11.71 0.28

42 9.6 -0.3 800 160 181 286 294 344 553 87 66 87 73 75 -0.063 11.7 0.3

43 9.4 -0.2 799 160 182 287 295 345 551 87 66 87 73 75 -0.064 11.59 0.29

44 9.3 -0.1 797 161 183 288 297 345 548 87 66 87 73 75 -0.063 11.42 0.31

45 9.1 -0.2 795 162 184 289 298 346 547 88 66 87 73 75 -0.063 11.4 0.34

46 8.9 -0.2 792 162 185 291 300 346 544 88 66 87 73 75 -0.063 11.46 0.31

47 8.7 -0.2 789 163 186 291 301 346 543 88 66 87 73 75 -0.063 11.39 0.33

48 8.6 -0.1 786 164 188 292 302 346 543 88 66 87 73 75 -0.063 11.4 0.33

49 8.4 -0.2 785 165 189 293 303 347 543 88 66 87 73 75 -0.063 11.4 0.36

50 8.2 -0.2 784 166 190 294 305 348 541 88 66 87 73 75 -0.063 11.52 0.35

51 8.0 -0.2 784 166 191 295 306 348 543 88 66 87 73 75 -0.063 11.65 0.34

52 7.9 -0.1 779 166 192 296 307 348 543 87 66 86 73 75 -0.063 11.84 0.32

53 7.7 -0.2 777 167 193 297 308 348 546 87 66 85 73 75 -0.062 12.11 0.29

54 7.5 -0.2 777 167 195 298 309 349 547 87 66 85 73 75 -0.062 12.2 0.28

55 7.4 -0.1 775 168 196 299 310 350 547 87 66 85 73 75 -0.062 12.37 0.24

56 7.2 -0.2 777 169 198 301 311 351 545 87 66 85 73 75 -0.063 12.41 0.24

57 7.0 -0.2 777 169 199 302 313 352 547 87 66 85 73 75 -0.062 12.42 0.23

58 6.8 -0.2 778 169 201 303 314 353 547 87 66 85 73 75 -0.062 12.51 0.22

59 6.6 -0.2 783 170 203 305 316 355 547 87 66 85 73 76 -0.063 12.51 0.22

60 6.3 -0.3 781 171 204 306 317 356 546 87 66 85 73 75 -0.062 12.39 0.21

61 6.2 -0.1 780 171 206 307 318 356 544 87 66 85 73 75 -0.062 12.25 0.2

62 6.0 -0.2 779 171 208 308 320 357 542 87 67 85 73 75 -0.061 12.14 0.21

63 5.8 -0.2 782 172 210 309 321 359 539 87 67 85 73 75 -0.061 12.03 0.2

64 5.7 -0.1 780 173 212 311 323 360 538 87 67 86 74 76 -0.061 11.91 0.2

65 5.5 -0.2 778 174 213 311 324 360 537 87 67 86 74 75 -0.061 11.78 0.2

66 5.4 -0.1 780 175 216 312 325 362 536 87 67 86 74 75 -0.060 11.8 0.19

67 5.2 -0.2 779 175 217 313 326 362 535 87 67 86 74 75 -0.061 11.68 0.18

68 5.0 -0.2 780 176 219 314 327 363 534 87 67 86 74 75 -0.061 11.71 0.19

69 4.8 -0.2 779 176 221 315 328 364 531 87 67 86 74 75 -0.061 11.67 0.18

70 4.7 -0.1 779 176 223 315 329 364 531 87 67 86 73 75 -0.060 11.76 0.17

71 4.6 -0.1 778 177 225 316 330 365 532 87 67 86 73 75 -0.060 11.77 0.16

72 4.4 -0.2 777 177 227 317 330 366 532 88 67 86 73 75 -0.060 11.68 0.17

73 4.3 -0.1 777 178 229 318 331 367 530 87 67 86 73 75 -0.059 11.64 0.16

Control No. P-SSAR-0003 Page 6 of 11 High Burn Run 5_Efficiency

99 of 190

ure:___________ ________________________________________________________________________________________________________________

Page 100: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 110 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: #DIV/0! scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm30-Apr-20 Dilution Tunnel Static: "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.81 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP "H2O

OMNI Equipment Numbers: Temp: °FVstrav ft/sec Vscent ft/sec Fp

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

74 4.1 -0.2 777 178 230 319 332 367 528 88 67 86 73 75 -0.059 11.54 0.16

75 4.0 -0.1 776 179 233 319 332 368 527 88 67 86 73 75 -0.058 11.49 0.16

76 3.8 -0.2 774 179 235 320 333 368 525 88 67 86 73 76 -0.058 11.44 0.17

77 3.7 -0.1 772 179 236 321 333 368 520 88 67 86 73 75 -0.058 11.4 0.17

78 3.5 -0.2 769 180 238 322 334 369 520 88 67 86 73 75 -0.058 11.26 0.18

79 3.4 -0.1 766 180 240 322 335 369 518 88 67 86 73 75 -0.057 11.16 0.2

80 3.2 -0.2 766 180 242 323 335 369 514 88 67 86 73 75 -0.058 11 0.2

81 3.1 -0.1 764 181 243 323 336 369 515 88 67 86 73 75 -0.058 10.92 0.2

82 3.0 -0.1 760 181 245 324 336 369 512 88 67 86 73 74 -0.058 10.8 0.21

83 2.9 -0.1 758 181 246 324 337 369 509 88 67 86 73 76 -0.058 10.69 0.22

84 2.7 -0.2 755 181 248 325 338 369 507 88 67 86 73 76 -0.056 10.57 0.24

85 2.6 -0.1 754 182 249 325 339 370 506 88 67 86 73 76 -0.057 10.58 0.25

86 2.4 -0.2 751 183 250 325 339 370 506 88 67 86 73 76 -0.056 10.53 0.26

87 2.3 -0.1 751 183 252 325 340 370 506 88 67 86 73 75 -0.058 10.45 0.26

88 2.2 -0.1 750 183 253 325 340 370 502 88 67 86 73 76 -0.058 10.44 0.26

89 2.1 -0.1 745 184 254 325 340 370 502 88 67 86 74 76 -0.058 10.13 0.36

90 2.0 -0.1 742 184 256 325 341 370 501 88 67 86 74 76 -0.057 10.08 0.36

91 1.9 -0.1 739 184 257 325 341 369 500 88 67 86 74 76 -0.057 10 0.39

92 1.8 -0.1 738 185 258 325 342 370 499 88 67 86 74 75 -0.057 9.94 0.37

93 1.7 -0.1 733 186 259 324 343 369 495 88 67 86 73 75 -0.057 9.84 0.38

94 1.5 -0.2 732 186 261 324 343 369 495 88 67 86 74 75 -0.057 9.81 0.4

95 1.4 -0.1 732 186 262 323 344 369 496 88 67 86 74 76 -0.057 9.95 0.34

96 1.3 -0.1 733 187 263 323 344 370 494 88 67 86 74 75 -0.057 9.9 0.35

97 1.2 -0.1 733 186 264 322 345 370 496 88 67 86 74 75 -0.057 9.96 0.33

98 1.1 -0.1 733 187 265 322 346 371 494 88 67 86 74 76 -0.057 9.93 0.31

99 1.0 -0.1 733 187 267 321 347 371 493 88 67 86 74 75 -0.057 9.87 0.31

100 0.9 -0.1 732 188 268 321 348 371 491 89 67 86 74 75 -0.057 9.83 0.33

101 0.8 -0.1 731 188 270 320 348 371 490 89 67 86 74 75 -0.056 9.78 0.34

102 0.7 -0.1 731 188 271 320 349 372 486 89 67 86 74 75 -0.056 9.77 0.33

103 0.6 -0.1 729 189 272 319 350 372 486 89 67 86 74 75 -0.056 9.74 0.36

104 0.5 -0.1 728 189 274 319 350 372 485 89 67 86 74 75 -0.056 9.73 0.37

105 0.4 -0.1 727 189 275 318 351 372 486 89 67 86 74 75 -0.055 9.7 0.36

106 0.3 -0.1 726 190 276 318 351 372 483 89 67 86 74 75 -0.055 9.68 0.38

107 0.3 0 723 190 277 317 352 372 482 89 67 86 74 74 -0.055 9.7 0.39

108 0.2 -0.1 721 190 278 317 353 372 480 89 67 86 74 74 -0.055 9.58 0.4

109 0.1 -0.1 718 191 280 316 353 372 478 89 67 86 74 74 -0.055 9.64 0.38

110 0.0 -0.1 715 191 281 316 353 371 475 89 67 86 74 75 -0.055 9.68 0.38

Control No. P-SSAR-0003 Page 7 of 11 High Burn Run 5_Efficiency

100 of 190

re:__________________________________________

Page 101: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Run: 5Travis Industries PM Control Modules: 371, 372Medium Flush Wood Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec.2408 110 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: #DIV/0! scfm Technician Signature:________________________________0028WN123E Recording Interval: 1 min Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: #DIV/0! scfm30-Apr-20 Dilution Tunnel Static: "H2O Post-Test Leak Check (1): 0.000 cfm @ in. Hg

Beginning Clock Time: 12:48 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ in. HgPitot Tube Cp: 0.99 Average Test Piece Fuel Moisture: 21.81 Dry Basis %

Meter Box Y Factor: 0.988 (1) 0.985 (2) (Amb)

Barometric Pressure: Begin Middle End Average Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

29.56 29.58 29.57 "Hg Initial dP "H2O

OMNI Equipment Numbers: Temp: °FVstrav ft/sec Vscent ft/sec Fp

Particulate Sampling Data

Elapsed Time (min)

Gas Meter 1

(ft3)

Gas Meter 2

(ft3)

Sample Rate 1 (cfm)

Sample Rate 2 (cfm)

Orifice dH 1

("H2O)

Meter 1 Temp (°F)

Meter 1 Vacuum

("Hg)

Orifice dH 2

("H2O)Meter 2

Temp (°F)

Meter 2 Vacuum

("Hg)

Dilution Tunnel (°F)

Dilution Tunnel

Center dP

Pro. Rate 1

Pro. Rate 2

Scale Reading

Weight Change Firebox Top Firebox

BottomFirebox

Back Firebox Left Firebox Right

Avg. Stove Surface Stack Filter 1 Dryer

Exit 1 Filter 2 Dryer Exit 2 Ambient

Draft ("H2O)

CO2

(%)CO (%)

Wood Heater Test Data - ASTM E3053 / ASTM E2515

Test Date:

Stack Gas DataFuel Weight (lb) Temperature Data (°F)

Velocity Traverse Data

Manufacturer: Model:

Tracking No.: Total Sampling Time: Project No.:

Avg/Tot 0.000 0.000 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! 112.8 66 86 73 74 -0.062

Control No. P-SSAR-0003 Page 8 of 11 High Burn Run 5_Efficiency

101 of 190

ure:______________________________

Page 102: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Travis IndustriesModel: Medium Flush Wood

Project No.: 0028WN123ETracking No.: 2408

Run: 5Test Date:

Burn Rate 3.90 kg/hr dry

Average Tunnel Temperature #DIV/0! degrees FahrenheitAverage Gas Velocity in Dilution Tunnel - vs #DIV/0! feet/secondAverage Gas Flow Rate in Dilution Tunnel - Qsd #DIV/0! dscf/hour

Average Delta p #DIV/0! inches H20Total Time of Test 110 minutes

Total Sample Volume - Vm 0.000 cubic feet 0.000 cubic feet 0.000 cubic feet 0.000 cubic feetAverage Gas Meter Temperature 74 degrees Fahrenheit #DIV/0! degrees Fahrenheit #DIV/0! degrees Fahrenheit #DIV/0! degrees FahrenheitTotal Sample Volume (Standard Conditions) - Vmstd 0.000 dscf #DIV/0! dscf #DIV/0! dscf #DIV/0! dscf

Total Particulates - mn 0 mg 5.5 mg 5.8 mg 2.7 mgParticulate Concentration (dry-standard) - Cr/Cs 0.000000 grams/dscf #DIV/0! grams/dscf #DIV/0! grams/dscf #DIV/0! grams/dscfTotal Particulate Emissions - ET #DIV/0! grams #DIV/0! grams #DIV/0! grams #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hour #DIV/0! grams/hour #DIV/0! grams/hour #DIV/0! grams/hourEmissions Factor #DIV/0! g/kg #DIV/0! g/kg #DIV/0! g/kg

Difference from Average Total Particulate Emissions #DIV/0! grams #DIV/0! grams

Complete Test RunTotal Particulate Emissions - ET #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hourEmissions Factor #DIV/0! grams/kg

First Hour EmissionsTotal Particulate Emissions - ET #DIV/0! gramsParticulate Emission Rate #DIV/0! grams/hourEmissions Factor #DIV/0! grams/kg

7.5% of Average Total Particulate Emissions #DIV/0! grams

Technician Signature:_____________________________________________________

Wood Heater Test Results - ASTM E3053 / ASTM E2515

04/30/20

SAMPLE TRAIN 1 SAMPLE TRAIN 2AMBIENT

QUALITY CHECKSFINAL AVERAGE RESULTS

FIRST HOUR FILTER (TRAIN 1)

#DIV/0!

Filter Temps < 90 °F OKOKOK

#DIV/0!

Stove Surface ∆T OK

OK

Filter Face Velocity (47 mm)Dryer Exit Temp < 80F

Leakage RateAmbient Temp (55-90°F)

Negative Probe Weight Eval.HECK 10 MIN. INTERVAL PRO-RATPro-Rate Variation

OK

Control No. P-SSAR-0003 High Burn Run 5_Efficiency102 of 190

______________________ _______________

Page 103: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Manufacturer: Travis Industries Technician Signature:Model:edium Flush Wood

Date: 04/30/20Run: 5

Control #: 0028WN123E Test Duration: 110

Output Category: IV

HHV Basis LHV BasisOverall Efficiency 70.3% 76.0%

Combustion Efficiency 97.8% 97.8%Heat Transfer Efficiency 72% 77.7%

Output Rate (kJ/h) 55,762 52,897 (Btu/h)Burn Rate (kg/h) 4.00 8.82 (lb/h)

Input (kJ/h) 79,287 75,212 (Btu/h)

Test Load Weight (dry kg) 7.34 16.17 dry lbMC wet (%) 17.90718039MC dry (%) 21.81

Particulate (g ) #DIV/0!CO (g) 243

Test Duration (h) 1.83

Emissions Particulate COg/MJ Output #DIV/0! 2.37

g/kg Dry Fuel #DIV/0! 33.06g/h #DIV/0! 132.33

lb/MM Btu Output #DIV/0! 5.52

Air/Fuel Ratio (A/F) 9.26

VERSION: 2.2 12/14/2009

Test Results in Accordance with CSA B415.1-09

Wood Heater Efficiency Results - CSA B415.1

103 of 190

e:

Page 104: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 VersionCordwood Fuel Load Calculators 10 lb/ft3 Nominal Load DensityCore 45 65% of Total Load Weight, Remainder 35 55% of Total Load Weight

Values to be input manuallyFor All Usable Firebox Volumes High Fire Test OnlyNominal Required Load Density (wet basis) 10 lb/ft3

Usable Firebox Volume 2.20 ft3

Total Nom. Load Wt. Target 22.00 lbTotal Load Wt. Allowable Range 20.90 to 23.10 lbCore Target Wt. Allowable Range 9.90 to 14.30 lbRemainder Load Wt. Allowable Range 7.70 to 12.10 lb

Mid PointCore Load Pc. Wt. Allowable Range 3.30 to 5.50 lb 4.40Remainder Load Pc. Wt. Allowable Range 2.20 to 12.10 lb 7.15 Fuel Piece Moisture Reading (% dry basis)

Pc. # 1 2 3 Ave.Core Load Piece Wt. Actual 1 4.72 lb In Range 19.1 18.8 19.7 19.2 In Range 3.96 lb 1.79 kg

2 4.26 lb In Range 21.9 20.6 21.7 21.4 In Range 3.50 lb 1.59 kg3 4.22 lb In Range 23.8 22.6 21.9 22.8 In Range 3.44 lb 1.56 kg

Core Load Total. Wt. Actual 13.19 lb In RangePc. #

Remainder Load Piece Wt. 1 4.87 lb In Range 24.2 23.2 23.8 23.7 In Range 3.93 lb 1.78 kg(1 to 3 Pcs.) 2 3.72 lb In Range 22.2 20.5 23.2 22.0 In Range 3.05 lb 1.38 kg

3 lb NA NA NA NA lb NA kgRemainder Load Tot. Wt. Act 8.58 lb In Range Total Load Ave. MC (% dry basis) 21.8 In RangeTotal Load Wt. Actual 21.77 lb In Range Total Load Ave. MC % (wet basis) 17.9Core % of Total Wt. 61% In Range 45 65% Total Test Load Weight (dry basis) 17.88 lb 8.11 kgRemainder % of Total Wt. 39% In Range 35 55%Actual Load % of Nominal Target 99% In Range 95 105% Kindling Moisture (% dry basis)Actual Fuel Load Density 9.9 lb/ft3 9.9 8.8 9.5 9.4 In Range 3.93 lb 1.78 kgKindling and Start up Fuel Start up Fuel Moisture Readings (% dry basis)Maximim Kindling Wt. (20% of Tot. Load Wt.) 4.35 lb 22.8 24.6 23.3 23.6 In Range 5.02 lb 2.28 kgActual Kindling Wt. 4.30 lb In Range 19.8%Maximum Start up Fuel Wt. (30% of Tot. Load Wt.) 6.53 lb Total Wt. All Fuel Added (dry basis) 26.82 lb 12.17 kgActual Start up Fuel Wt. 6.20 lb In Range 28.5% Total Wt. All Fuel Burned (dry basis) 21.4 lb 9.7 kgAllowable Residual Start up Fuel Wt. Range 2.2 to 4.4 lb Mid PointActual Residual Start up Fuel Wt. 3.3 lb In Range 3.3Total Wt. All Fuel Added (wet basis) 32.27 lbHigh Fire Test Run End Point Range Low High Mid PointBased on Fuel Load Wt. (w/tares) 2.0 to 2.4 lb 2.2Actual Fuel Load Ending Wt. 2.1 lb In Range

Pc. Wt. Dry Basis

THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING JURISDICTION AND THE PRESIDENT OF THE SOCIETY. COPYRIGHT ASTM, 100 BARR HARBOR DRIVE, WEST CONSHOHOCKEN, PA 19428. ALL RIGHTS RESERVED.

104 of 190

Page 105: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Section 4 Quality Assurance/Quality Control

105 of 190

Page 106: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

QUALITY ASSURANCE/QUALITY CONTROL

OMNI follows the guidelines of ISO/IEC 17025, “General Requirements for the Competence of Testing and Calibration Laboratories,” and the quality assurance/quality control (QA/QC) procedures found in OMNI’s Quality Assurance Manual.

OMNI’s scope of accreditation includes, but is not limited to, the following:

ANSI (American National Standards Institute) for certification of product to safety standards. To perform product safety testing by the International Accreditation Service, Inc. (formerly ICBO ES) under accreditation as a testing laboratory designated TL-130. To perform product safety testing as a “Certification Organization” by the Standards Council of Canada (SCC). Serving as a testing laboratory for the certification of wood heaters by the U.S. Environmental Protection Agency.

This report is issued within the scope of OMNI’s accreditation. Accreditation certificates are available upon request.

The manufacturing facilities and quality control system for the production of the Medium Flush Wood Insert at Travis Industries, Inc. were evaluated to determine if sufficient to maintain conformance with OMNI’s requirements for product certification. OMNI has concluded that the manufacturing facilities, processes, and quality control system are adequate to produce the appliance congruous with the standards and model codes to which it was evaluated.

This report shall not be reproduced, except in full, without the written approval of OMNI-Test Laboratories, Inc.

106 of 190

Page 107: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Sample Analysis Analysis Worksheets

Tared Filter, Probe, and O-Ring Data

107 of 190

Page 108: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

108 of 190

Page 109: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

109 of 190

Page 110: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

110 of 190

Page 111: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

111 of 190

Page 112: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

112 of 190

Page 113: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

113 of 190

Page 114: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

114 of 190

Page 115: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

115 of 190

Page 116: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

116 of 190

Page 117: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

117 of 190

Page 118: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Calibrations

Methods EPA 28R, ASTM E2515, ASTM E3053

ID # Lab Name/Purpose Log Name Attachment Type

132 10 lb Weight Weight Standard, 10 lb. Calibration Certificate

181062211 Platform Scale 1000 lb. at 0.1 resolution Calibration Certificate

283A Audit Weights Troemner 21pc Msas Set Calibration Certificate

371 Sample Box / Dry Gas Meter

Apex Automated Emissions Sampling Box

Calibration Log

372 Sample Box / Dry Gas Meter

Apex Automated Emissions Sampling Box

Calibration Log

410 Microtector Dwyer Microtector Calibration Certificate

559 Vaneometer Dwyer Vaneometer Equipment Record

592 Thermohygrometer Omega Digital Thermohygrometer

Calibration Log

594 Combustion Gas Analyzer

CAI Gas Analyzer See Run Sheet

637 Milligram Balance Analytical Balance - Mettler - Toledo

Calibration Certificate

118 of 190

Page 119: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

119 of 190

Page 120: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

120 of 190

Page 121: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

121 of 190

Page 122: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

122 of 190

Page 123: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI Test Laboratories, Inc.

Thermal Metering System CalibrationY Factor

Previous Calibration Comparision

Manufacturer: Apex Date 7/2/2019Acceptable

Deviation (5%) DeviationModel: XC-60-EP y Factor 0.992 0.0496 0.004Serial Number: 0702003 Acceptance AcceptableOMNI Tracking No.: OMNI-00371Calibrated Orifice: FALSE Current Calibration

Acceptable y Deviation 0.020

Average Gas Meter y Factor

Orifice MeterdH@ Maximum y Deviation 0.008 TRUE

0.988 N/A Acceptable dH@ Deviation N/ACalibration Date: 01/03/20 Maximum dH@ Deviation N/A N/ACalibrated by: B. Davis Acceptance AcceptableCalibration Frequency: 6 monthsNext Calibration Due: 7/3/2020Instrument Range: 1.000 cfmStandard Temp.: 68 oF Reference Standard *Standard Press.: 29.92 "Hg Standard Model Standard Test MeterBarometric Press., Pb: 30.2 "Hg Calibrator S/N OMNI-00001Signature/Date: 1/16/2020 Calib. Date 25-Nov-19

Calib. Value 0.9981 y factor (ref)

Calibration Parameters Run 1 Run 2 Run 3

Reference Meter Pressure ("H2O), Pr 0.00 0.00 0.00DGM Pressure ("H2O), Pd 3.00 1.70 0.90Initial Reference Meter 644.9 636.8 631.5Final Reference Meter 650.008 644.805 636.604Initial DGM 0 0 0Final DGM 5.112 8.045 5.184Temp. Ref. Meter (°F), Tr 76.0 79.0 75.0Temperature DGM (°F), Td 79.0 75.0 78.0Time (min) 26.3 49.3 50.3Net Volume Ref. Meter, Vr 5.108 8.005 5.104Net Volume DGM, Vd 5.112 8.045 5.184Gas Meter y Factor = 0.996 0.982 0.986Gas Meter y Factor Deviation (from avg.) 0.008 0.006 0.002Orifice dH@ N/A N/A N/AOrifice dH@ Deviation (from avg.) N/A N/A N/A

where:1. Deviation = |Average value for all runs - current run value|

** 2. y = [Vr x (y factor (ref)) x (Pb + (Pr/ 13.6)) x (Td + 460) ]/ [Vd x (Pb + (Pd / 13.6)) x (Tr + 460)]** 3. dH@ = 0.0317 x Pd / (Pb (Td + 460)) x [ (Tr + 460) x time) / Vr ]^2

* Reference calibration is traceable to NIST through NIST Test # 40674, Kimble ASTM E1272, or NIST traceable laboratory** Equations come from EPA Method 5The uncertainty of measurement is ±0.14 ft3/min. This is based on the reference standard having a TAR (Test Accuracy Ratio) of at least 4:1.

Yes

Control No. C SSB 0005, Effective Date: 7/7/2011

1/17/20

s

123 of 190

30.2

Page 124: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Control No. C-SFAK-0001, Effective date: 12/2/2015 Page 1 of 1

DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET

Instrument to be calibrated: Pressure Transducer______________

Maximum Range: 0-2” WC ID Number: OMNI-00371

Calibration Instrument: Digital Manometer ID Number: OMNI-00633

Date: 1/13/20 By: B. Davis

This form is to be used only in conjunction with Standard Procedure C-SPC.

*Acceptable tolerance is 4%.

The uncertainty of measurement is ±0.4” WC. This is based on the reference standard having a TAR (Test Accuracy Ratio) of at least 4:1.

Technician signature: Date: _1/13/2020__

Reviewed by: Date: ______

Range of Calibration Point

( WC)

Digital Manometer

Input( WC)

Pressure Gauge Response

( WC)

Difference (Input -

Response)

% Error of Full Span*

0-20% Max. Range 0 - 0.4 0.068 0.073 0.005 0.25

20-40% Max. Range 0.4 - 0.8 0.555 0.561 0.006 0.30

40-60% Max. Range 0.8 – 1.2 0.946 0.950 0.004 0.20

60-80% Max. Range 1.2 – 1.6 1.223 1.230 0.007 0.35

80-100% Max. Range 1.6 – 2.0 1.734 1.735 0.001 0.05

1/17/20

124 of 190

Page 125: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

125 of 190

Page 126: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI Test Laboratories, Inc.

Thermal Metering System CalibrationY Factor

Previous Calibration Comparision

Manufacturer: Apex Date 7/2/2019Acceptable

Deviation (5%) DeviationModel: XC-60-EP y Factor 0.989 0.04945 0.004Serial Number: 0702004 Acceptance AcceptableOMNI Tracking No.: OMNI-00372Calibrated Orifice: FALSE Current Calibration

Acceptable y Deviation 0.020

Average Gas Meter y Factor

Orifice MeterdH@ Maximum y Deviation 0.014 TRUE

0.985 N/A Acceptable dH@ Deviation N/ACalibration Date: 01/06/20 Maximum dH@ Deviation N/A N/ACalibrated by: B. Davis Acceptance AcceptableCalibration Frequency: 6 monthsNext Calibration Due: 7/6/2020Instrument Range: 1.000 cfmStandard Temp.: 68 oF Reference Standard *Standard Press.: 29.92 "Hg Standard Model Standard Test MeterBarometric Press., Pb: 30.33 "Hg Calibrator S/N OMNI-00001Signature/Date: 1/16/2020 Calib. Date 25-Nov-19

Calib. Value 0.9981 y factor (ref)

Calibration Parameters Run 1 Run 2 Run 3

Reference Meter Pressure ("H2O), Pr 0.00 0.00 0.00DGM Pressure ("H2O), Pd 2.00 1.00 0.80Initial Reference Meter 663.4 672.9 682.6Final Reference Meter 672.8 682.505 688.3Initial DGM 0 0 0Final DGM 9.416 9.712 5.872Temp. Ref. Meter (°F), Tr 74.0 74.0 75.0Temperature DGM (°F), Td 76.0 76.0 77.0Time (min) 53.8 30.3 51.8Net Volume Ref. Meter, Vr 9.400 9.605 5.700Net Volume DGM, Vd 9.416 9.712 5.872Gas Meter y Factor = 0.995 0.988 0.971Gas Meter y Factor Deviation (from avg.) 0.011 0.004 0.014Orifice dH@ N/A N/A N/AOrifice dH@ Deviation (from avg.) N/A N/A N/A

where:1. Deviation = |Average value for all runs - current run value|

** 2. y = [Vr x (y factor (ref)) x (Pb + (Pr/ 13.6)) x (Td + 460) ]/ [Vd x (Pb + (Pd / 13.6)) x (Tr + 460)]** 3. dH@ = 0.0317 x Pd / (Pb (Td + 460)) x [ (Tr + 460) x time) / Vr ]^2

* Reference calibration is traceable to NIST through NIST Test # 40674, Kimble ASTM E1272, or NIST traceable laboratory** Equations come from EPA Method 5The uncertainty of measurement is ±0.14 ft3/min. This is based on the reference standard having a TAR (Test Accuracy Ratio) of at least 4:1.

Yes

Control No. C SSB 0005, Effective Date: 7/7/2011

meters

1/17/20

126 of 190

30.33

Page 127: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Control No. C-SFAK-0001, Effective date: 12/2/2015 Page 1 of 1

DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET

Instrument to be calibrated: Pressure Transducer______________

Maximum Range: 0-2” WC ID Number: OMNI-00372

Calibration Instrument: Digital Manometer ID Number: OMNI-00633

Date: 1/13/20 By: B. Davis

This form is to be used only in conjunction with Standard Procedure C-SPC.

*Acceptable tolerance is 4%.

The uncertainty of measurement is ±0.4” WC. This is based on the reference standard having a TAR (Test Accuracy Ratio) of at least 4:1.

Technician signature: Date: _1/13/2020__

Reviewed by: Date: ______

Range of Calibration Point

( WC)

Digital Manometer

Input( WC)

Pressure Gauge Response

( WC)

Difference (Input -

Response)

% Error of Full Span*

0-20% Max. Range 0 - 0.4 0.018 0.017 0.001 0.05

20-40% Max. Range 0.4 - 0.8 0.733 0.732 0.001 0.05

40-60% Max. Range 0.8 – 1.2 1.002 1.001 0.001 0.05

60-80% Max. Range 1.2 – 1.6 1.370 1.368 0.002 0.10

80-100% Max. Range 1.6 – 2.0 1.850 1.851 0.001 0.05

1/17/20

127 of 190

Page 128: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

128 of 190

Page 129: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

129 of 190

Page 130: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

130 of 190

Page 131: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

131 of 190

Page 132: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

JJ Calibrations, Inc.7724 SE Aspen Summit DrivePortland, OR 97266-9217Phone 503.786.3005FAX 503.786.2994

Certificate of CalibrationCertificate Number: 716748

PO:

Property #:

Serial #:

User:

Model:

Description:

Make:

Accuracy:

*Recommended Due:

As Received:As Returned:

Action Taken:

Order Date:

Procedure:

Calibrated on:

Technician:

°C % RHEnvironment:Department:

B729400181

N/A

Mettler Toledo

07/20/2020

Within Tolerance

01/20/202020

135Calibrated

±0.0005gDCN 500887

N/A

19026901/20/2020

OMNI-00637

Analytical Scale, 120g

Within Tolerance40

OnSi te

MS104TS/00

Authorized By: N/A0723.01

723A Rice Lake 1mg-200g (Class 0) Mass Set, 05/22/2020 694890Std ID Manufacturer Model Nomenclature Due Date Trace ID

Standards Used

ParameterUnit UUT UncertaintyMeasurement Description Range

Measurement Data

Before/After Accredited = Min MaxReference *ErrorForce

g 9.7E-05 10.00000 10.0001 0.0001 9.9995 10.0005 gg 1.2E-04 30.00000 30.0003 0.0003 29.9995 30.0005 gg 1.8E-04 60.00000 60.0002 0.0002 59.9995 60.0005 gg 2.4E-04 90.00000 90.0001 0.0001 89.9995 90.0005 gg 3E-04 120.00000 120.0000 0.0000 119.9995 120.0005 g

Remarks: * Many factors may cause the unit to drift out of calibration before the recommended due date. Any reported error is the absolute value between the reference and the unit.

Omni-Test Laboratories13327 NE Airport WayPortland, OR 97230

Calibration

Uncertainties include the effects of the unit.

**

InspectorRev #Issued 1501/22/2020Reviewer 3

This instrument has been calibrated in accordance with the JJ Calibrations Quality Assurance Manual and is traceable to either the SI or to National Institute ofStandards and Technology (NIST). The quality system and this certificate are in compliance with ANSI/NCSL Z540-1-1994, ISO/IEC 17025-2017, ISO

10012-1, the ISO 9000 family and QS 9000. The expanded uncertainties of measurements for this calibration are based upon 95% (2 sigma) confidence limits.Unless stated in the comments, certificates reflect the "Simple Acceptance Rule" as specified by JCGM 106:2012. Unless otherwise stated, a test accuracy ratio

(TAR) of 4:1, if achievable, is maintained. The results reported herein apply only to the calibration of the item described above. This report may not be

Page 1 of 1Certificate: 716748 132 of 190

Page 133: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Example Calculations

133 of 190

Page 134: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Manufacturer: Model:

Run: Category:

BR – Dry burn rate, kg/hr

Vs – Average gas velocity in the dilution tunnel, ft/sec

Qsd – Average gas flow rate in dilution tunnel, dscf/hr

Vm(std) – Volume of gas sampled, corrected to dry standard conditions, dscf

mn – Total particulate matter collected, mg

Cs - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf

ET – Total particulate emissions, g

PR - Proportional rate variation

PMR – Particulate emissions for test run, g/hr

PMF – Particulate emission factor for test run, g/dry kg of fuel burned

Equations and Sample Calculations – ASTM E3053 & E2515

Travis IndustriesMedium Flush Wood2

are provided for each equation. The raw data and printout results from a sample run are also provided for

Equations used to calculate the parameters listed below are described in this appendix. Sample calculations

comparison to the sample calculations.

Control No. P-SSAR-0003 Low Burn Run 2134 of 190

Page 135: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

BR – dry burn rate, kg/hrASTM E2780 equation (5)

60 MFTAdb

Where,

= Total length of test run, min

Sample Calculation:

MBdb = 9.83 kg

= 510 min

60 x 9.83

BR = 1.16 kg/hr

BR =

BR = 510

Control No. P-SSAR-0003 Low Burn Run 2135 of 190

Page 136: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Vs – Average gas velocity in the dilution tunnel, ft/secASTM E2515 equations (9)

Where:

vscent = Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec

vstrav = Dilution tunnel velocity calculated after the multi-point pitot traverse, ft/sec

kp = Pitot tube constant, 85.49

Cp = Pitot tube coefficient: 0.99, unitless

P* = Velocity pressure in the dilution tunnel, in H2O

Ts = Absolute average gas temperature in the dilution tunnel, °R; (°R = °F + 460)

Ps = Absolute average gas static pressure in dilution tunnel, = Pbar + Pg , in Hg

Pbar = Barometric pressure at test site, in. Hg

Pg = Static pressure of tunnel, in. H20; (in Hg = in H20/13.6)

Ms = **The dilution tunnel wet molecular weight; Ms = 28.78 assuming a dry weight of 29 lb/lb-mole

Sample calculation:

19.55

20.14

89.0 + 1/2

Vs = 0.971 x 85.49 x 0.99 x 0.300 x -0.18

13.6Vs = 19.76 ft/s

*The ASTM test standard mistakenly has the square root of the average delta p instead of

the average of the square root of delta p. The current EPA Method 2 is also incorrect. This

was verified by Mike Toney at EPA.

**The ASTM test standard mistakenly identifies Ms as the dry molecular weight. It should be

the wet molecular weight as indicated in EPA Method 2.

28.7829.70 +((

Fp = = 0.971

)460

) x

, ASTM E2515 Equation (1)Fp = Adjustment factor for center of tunnel pitot tube placement, Fp = Vstrav

Vscent

ss

avgsavgppPs MP

TPCkFv )()(

Control No. P-SSAR-0003 Low Burn Run 2136 of 190

Page 137: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Qsd – Average gas flow rate in dilution tunnel, dscf/hrASTM E2515 equation (3)

Where:

3600 = Conversion from seconds to hours (ASTM method uses 60 to convert in minutes)

Bws = Water vapor in gas stream, proportion by volume; assume 2%

A = Cross sectional area of dilution tunnel, ft2

Tstd = Standard absolute temperature, 528 °R

Ps = Absolute average gas static pressure in dilution tunnel, = Pbar + Pg , in Hg

Ts(avg) = Absolute average gas temperature in the dilution tunnel, °R; (°R = °F + 460)

Pstd = Standard absolute pressure, 29.92 in Hg

Sample calculation: -0.18

13.6

89.0 + 460

Qsd = 13063.8 dscf/hr

Qsd = 3600 x (1 - 0.02) x 29.92

19.76 x 0.196 x528

x

29.7 +

std

s

avgs

stdswssd P

PT

TAvBQ)(

)1(3600

Control No. P-SSAR-0003 Low Burn Run 2137 of 190

Page 138: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Vm(std) – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscfASTM E2515 equation (6)

Where:

K1 = 17.64 °R/in. Hg

Vm = Volume of gas sample measured at the dry gas meter, dcf

Y = Dry gas meter calibration factor, dimensionless

Pbar = Barometric pressure at the testing site, in. Hg H = Average pressure differential across the orifice meter, in. H2O

Tm = Absolute average dry gas meter temperature, °R

Sample Calculation:

Using equation for Train 1: 2.27

Vm(std) = 17.64 x 84.012 x 0.988 x 13.6

( 78.1 + 460 )

Vm(std) = 81.273 dscf

Using equation for Train 2: 1.79

Vm(std) = 17.64 x 89.207 x 0.985 x 13.6

( 78.0 + 460 )

Vm(std) = 85.947 dscf

Using equation for ambient train: 0.00

Vm(std) = 17.64 x 0.00 x 0 x 13.6( 74.1 + 460 )

Vm(std) = 0 dscf

(

( 29.7 + )

( 29.7 )+

29.7 + )

Control No. P-SSAR-0003 Low Burn Run 2138 of 190

Page 139: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

mn – Total Particulate Matter Collected, mgASTM E2515 Equation (12)

Where:

mp = mass of particulate matter from probe, mg

mf = mass of particulate matter from filters, mg

mg = mass of particulate matter from filter seals, mg

Sample Calculation:

Using equation for Train 1 (first hour):

mn = 0.0 + 7.2 + 0.0

mn = 7.2 mg

Using equation for Train 1 (post-first hour):

mn = 0.8 + 3.8 + 2.2

mn = 6.8 mg

Train 1 aggregate:

mn = 7.2 + 6.8

mn = 14.0 mg

Using equation for Train 2:

mn = 1 + 12.9 + 0.3

mn = 14.2 mg

gfpn mmmm

Control No. P-SSAR-0003 Low Burn Run 2139 of 190

Page 140: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

Cs - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscASTM E2515 equation (13)

Where:

K2 = Constant, 0.001 g/mg

mn = Total mass of particulate matter collected in the sampling train, mg

Vm(std) = Volume of gas sampled corrected to dry standard conditions, dscf

Sample calculation:

For Train 1:

14.0

81.27

Cs = 0.00017 g/dscf

For Train 2

14.2

85.95

Cs = 0.00017 g/dscf

For Ambient Train

0.0

0

Cr = 0 g/dscf

0.001 x

Cs = 0.001 x

Cr = 0.001 x

Cs =

)(2

stdm

ns V

mKC

Control No. P-SSAR-0003 Low Burn Run 2140 of 190

Page 141: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

ET – Total Particulate Emissions, gASTM E2515 equation (15)

Where:

Cs = Concentration of particulate matter in tunnel gas, g/dscf

Cr = Concentration particulate matter room air, g/dscf

Qstd = Average dilution tunnel gas flow rate, dscf/hr

= Total time of test run, minutes

Sample calculation:

For Train 1

ET = ( 0.000172 - 0 ) x 13063.8 x 510 /60

ET = 19.13 g

For Train 2

ET = ( 0.000165 - 0 ) x 13063.8 x 510 /60

ET = 18.35 g

Average

E = 18.74 g

Total emission values shall not differ by more than 7.5% from the total average emissions

7.5% of the average = 1.41

Train 1 difference = 0.39Train 2 difference = 0.39

stdrsT QccE

Control No. P-SSAR-0003 Low Burn Run 2141 of 190

Page 142: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

PR - Proportional Rate VariationASTM E2515 equation (16)

Where:

= Total sampling time, min

i = Length of recording interval, min

Vmi = Volume of gas sample measured by the dry gas meter during the “ith”

time interval, dcf

Vm = Volume of gas sample as measured by dry gas meter, dcf

Vsi = Average gas velocity in the dilution tunnel during the "ith" time interval, ft/sec

Vs = Average gas velocity in the dilution tunnel, ft/sec

Tmi = Absolute average dry gas meter temperature during the "ith" time interval, oR

Tm = Absolute average dry gas meter temperature, oR

Tsi = Absolute average gas temperature in the dilution tunnel during the "ith" time interval, oR

Ts = Absolute average gas temperature in the dilution tunnel, oR

Sample calculation (for the first 1 minute interval of Train 1):

510 x 1.637 x 19.76 x ( 132.0 + 460 ) x ( 78.1 + 460 )

10 x 84.01 x 20.52 x ( 89.0 + 460 ) x ( 78.0 + 460 )

PR = 103 %

x 100)(PR =

100smisimi

simsmi

TTVVTTVV

PR

Control No. P-SSAR-0003 Low Burn Run 2142 of 190

Page 143: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

PMR – Particulate emissions for test run, g/hrASTM E2780 equation (6)

PMR = 60 (ET/ )

Where,

ET = Total particulate emissions, grams

= Total length of full integrated test run, min

Sample Calculation:

ET (Dual train average) = 18.74 g

= 510 min

PMR = 60 x ( 18.74 / 510 )

PMR = 2.20 g/hr

Control No. P-SSAR-0003 Low Burn Run 2143 of 190

Page 144: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

OMNI-Test Laboratories, Inc.

PMF – Particulate emission factor for test run, g/dry kg of fuel burnedASTM E2780 equation (7)

PMF = ET/MFTAdb

Sample Calculation:

ET (Dual train average) = 18.74 g

MBdb = 9.83 kg

PMF = 18.74 / 9.83

PMF = 1.91 g/kg

Control No. P-SSAR-0003 Low Burn Run 2144 of 190

Page 145: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Section 5

Firebox Volume

145 of 190

Page 146: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

145 of 189

Page 147: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Appendix A Alt-125 E3053 Letter

Page 148: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

147 of 189

Page 149: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

148 of 189

Page 150: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

149 of 189

Page 151: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E

OMNI-Test Laboratories, Inc.

Appendix B Labeling & Owner’s Manual

Page 152: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

DO NOT REMOVE THIS LABELCONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA.

SUITABLE FOR USE IN FACTORY-BUILT (Z.C.) FIREPLACES AND MASONRY FIREPLACES.Report No. 100289794PRT-001

Control No. 4000515

MODEL:

with Nex-Gen™MED. FLUSH WOOD

Certified for USA and Canada

SERIAL NO:

CERTIFIED TO UL STD 1482; CERTIFIED TO ULC STD S628-1993

PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer’s installation and operating instructions. Contact your local building or fire officials about restrictions and installation inspection in your area. Refer to local building codes and manufacturer’s instructions for precautions required for passing a chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue serving another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building or fire officials. This wood heater needs periodic inspection and repair for proper operation. Consult owner’s manual for further information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating instructions in the owner’s manual. Refer to the Intertek Directory of Building Products (https://bpdirectory.intertek.com) for detailed information.

Do not route power cord under or in front of appliance.Replace glass only with 5mm neoceramic orceramic glass.Electrical Rating: 115V., 60 Hz, 1.8 AmpsBlowers: # 228-10069 / 228-10070

OMNI-Test Laboratories, Inc.Report No. 0028WN123E

U.S. ENVIRONMENTAL PROTECTION AGENCYCertified to comply with 2020 particulate emission standards using cord wood.

2.45 g/h, EPA Alt-125, ASTM E3053-17, ASTM 2515-11, CSA B415.1-10

TRAVIS INDUSTRIES, INC.12521 Harbour Reach Drive

Mukilteo, WA 98275

Manufactured by:

www.travisproducts.com

Made in U.S.A.2019 2020 2021 2022 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

DATE OF MANUFACTURE

1312

Page 153: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Medium Flush Wood Insert

(Rectangular or Arched)

with NexGen™ Technology

Manual Masonry Fireplace Insert Zero-Clearance (Metal) Fireplace Insert

Save these instructions for future reference

SAFETY NOTICE: If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Travis Industries, Inc. 12521 Harbour Reach Drive

Mukilteo, WA 98275 www.travisproducts.com

Copyright 2020 , T.I.

$10.00 100-01531 5/14/2020

Listed Tested to: U.L. 1482 & ULC S628

Page 154: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

2 Introduction

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Introduction We welcome you as a new owner of a Medium Flush Wood Insert. In purchasing a Medium Flush Wood Insert you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. This insert is one of the finest appliances the world over. This manual will explain the installation, operation, and maintenance of this appliance. Please familiarize yourself with the Owner's Manual before operating your appliance and save the manual for future reference. Included are helpful hints and suggestions which will make the installation and operation of your new appliance an easier and more enjoyable experience. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your appliance.

Important Information

No other Medium Flush Wood Insert appliance has the same serial number as yours. The serial number is on the label on the back of the appliance. This serial number will be needed in case you require service of any type. Model: Medium Flush Wood Insert_ Serial Number: Purchase Date: Purchased From:

Register your warranty online at:

traviswarranty.com

Save Your Bill of Sale. To receive full warranty coverage, you will need to show evidence of the date you purchased your heater. We suggest that you attach your Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur.

Page 155: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Table of Contents 3

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Introduction ...................................................... 2Important Information ...................................... 2Installation Options .......................................... 6Features ............................................................ 6Heating Specifications ..................................... 6Dimensions ....................................................... 6Emissions and Efficiency ................................ 6Planning the Installation .................................. 7Preparation for Installation ............................. 7Packing List ...................................................... 7Additional Accessories Needed for Installation ........................................................ 7Additional Requirements for Canada ............. 7Fireplace Requirements .................................. 8Fireplace Altered Tag ....................................... 8Insert Placement Requirements ..................... 9Masonry Fireplace - Hearth Requirements .. 10Zero-Clearance (Metal) Fireplace - Hearth Requirements ................................................. 10Masonry Fireplace Requirements ................ 10Zero-Clearance (Metal) Fireplace Requirements ................................................. 10Drafting Performance .................................... 12Insert Rollers .................................................. 12Leveling Bolt Installation ............................... 12Flue Installation .............................................. 13

Sealing the Flue to the Insert .............................. 13Insert with Direct Connection (Masonry Fireplace)14

Surround Panel Installation .......................... 15Face Installation ............................................. 15Electrical Requirements ................................ 15Re-Routing the Electrical Cord to the Left Side .................................................................. 16Safety Notice .................................................. 17Before Your First Fire .................................... 17

Verify the Installation ........................................... 17Curing the Paint .................................................. 17Carbon Monoxide (CO) Emissions ...................... 17Over-Firing the Stove .......................................... 17

Opening the Door ........................................... 18Opening the Door ................................................ 18

Closing the Door ................................................. 18Bypass Operation .......................................... 19Starting a Fire ................................................. 20Adjusting the Burn Rate ................................ 21

Approximate Air Control Settings: ....................... 21Understanding Your Heater’s Combustion System ............................................................ 22Burning Your Heater ...................................... 22Blower Operation ........................................... 23Re-Loading the Stove .................................... 23Overnight Burn ............................................... 23Normal Operating Sounds ............................ 23Hints for Burning ........................................... 24Selecting Wood .............................................. 24

Why Dry Wood is Key ......................................... 24Wood Cutting and Storage .................................. 24Do Not Burn List .................................................. 25

Troubleshooting ............................................. 26Daily Maintenance (while stove is in use) ... 27

Remove Ash (if necessary) ................................. 27Clean the Glass (if necessary) ............................ 27

Monthly Maintenance (while appliance is in use) .................................................................. 28

Door and Glass Inspection .................................. 28Door Latch Adjustment ....................................... 28Creosote - Formation and Need for Removal ..... 28

Yearly Maintenance ....................................... 29Touch-Up Paint ................................................... 29Cleaning the Air Duct and Blower (if applicable) . 29Firebrick and Baffle Inspection ............................ 29

Door Parts ....................................................... 30Replacing the Glass ............................................ 30Replacing the Door Gasket ................................. 30

Blower and Electrical Parts .......................... 31Firebox Parts .................................................. 32

Baffle Parts ......................................................... 32Baffle Removal .................................................... 32Air Tube Removal & Replacement ...................... 33Brick Removal & Replacement ........................ 34

Listing Label ................................................... 37

Page 156: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

4 Safety Precautions

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

The viewing door must be closed and latched during operation. Smoke from this appliance may active a smoke detector when the door is open. Never block free airflow through the air vents on this appliance.

Gasoline or other flammable liquids must never be used to start the fire or "Freshen Up" the fire. Do not store or use gasoline or other flammable liquids in the vicinity of this appliance.

This appliance is designed and approved for the burning of cord wood only. Do not attempt to burn any other type of fuel other than cord wood in this appliance, it will void all warranties and safety listings.

Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well away from the home or structure.

Do not touch the appliance while it is hot and educate all children of the danger of a high-temperature appliance. Young children should be supervised when they are in the same room as the appliance.

Keep furniture, drapes, curtains, wood, paper, and other combustibles a minimum of 36" away from the front of the appliance.

This appliance must be properly installed to prevent the possibility of a house fire. The instructions must be strictly adhered to. Do not use makeshift methods or compromise in the installation.

Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this appliance as well.

Inspect the chimney connector and chimney at least twice monthly and clean if necessary. Creosote may build up and cause a house fire. Do not connect this appliance to any chimney serving another appliance.

This appliance must be connected to a listed high temperature (UL 103 HT) residential type chimney or an approved masonry chimney with a standard clay tile, or stainless steel liner.

Gas

ASHES

36"

Ok

TypeHT

ClayLiner

Page 157: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Safety Precautions 5

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Never try to repair or replace any part of this appliance unless instructions are given in this manual. All other work must be done by a trained technician. Do not make any changes or modifications to an existing masonry fireplace or chimney to install this appliance.

Do not place clothing or other flammable items on or near this appliance.

Allow the appliance to cool before carrying out any maintenance or cleaning.

This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.

Maintain the door and glass seal and keep them in good condition. Do not operate this heater with broken or missing glass. Avoid placing wood against the glass when loading. Do not slam the door or strike the glass.

Over-firing the appliance may cause a house fire. If a unit or chimney connector glows, you are over-firing.

Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.

Do not use a grate or other device to elevate the fire off of the firebox floor. Burn the fire directly on the bricks.

Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your appliance, and assumes no responsibility of any consequential damage(s).

Smoke and CO Detectors: Make sure your home has a working smoke detector, especially near any bedrooms. We recommend having a smoke and/or CO detector in the same room as the wood heater for additional safety.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6

Travis Wood Burning Fireplaces, Stoves and Inserts are protected by one or more of the following patents; U.S. 9,170,025 4,665,889 as well as other U.S. and Foreign Patents pending.

This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.

���

ThisManual

Page 158: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

6 Stove Installation (for qualified installers only)

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Installation Options Masonry Fireplace Insert Zero-Clearance (Metal) Fireplace Insert

Features 2.2 Cubic Foot Firebox Volume Single Air Control Accepts Logs Up to 24" Long Steel Plate Construction (Up to 5/16") Heavy Duty Refractory Firebrick Standard High-Tech Blower

Heating Specifications Approximate Maximum Heating Capacity (in square feet)* 1,500 to 2,000 EPA Tested Cord Wood BTUs per Hour** 15,853 to 55,395 Maximum Burn Time Up to 8 Hours * Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected by the quality and moisture level of the fuel.

** EPA tests to determine BTU output are achieved with a single load of wood at each burn rate. At home, you are likely to add more wood to your insert to maintain your desired comfort level. By the simple process of loading your fireplace insert with additional wood, you could achieve up to a 20% higher heat output than established during EPA testing. This model was tested for efficiency using method B415.1-10 and was determined to have a weighted average Higher Heating Value (HHV) Overall Heating Efficiency (OHE) of 72.2%. Overall efficiency of the heater may be lower if the heater is operated without a heat exchange blower or with the installed heat exchange blower turned off.

Dimensions

Figure 1 (a) Measure clearances from base of insert (b) Fireplace Opening

Emissions and Efficiency This heater meets the 2020 U.S. EPA’s cord wood emission limits for wood heaters. Tested to EPA Alt-125, ASTM E3053-17, ASTM 2515-11, CSA B415.1-10 this heater has been shown to deliver heat at rates ranging from 15,853 to 55,395 BTU/hr and an emission value of 2.45g/h. Report No. 0028WN123E

6-3/8"(162mm)

450 Lbs. (200 Kg)6" (153mm) Dia.

19"(483mm)

21-1/2"(547mm)

a

b

28-7/8" (734mm)

19-3/4"(502mm)

18-7/8"(480mm)

10"(254mm)

Page 159: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Fireplace Insert Installation (for qualified installers only) 7

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

SAFETY NOTICE: Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Planning the Installation

We suggest that you have an authorized Travis Industries dealer install your fireplace insert. If you install the fireplace insert yourself, your authorized dealer should review your installation plans.

Check with local building officials for any permits required for installation of this fireplace insert and notify your insurance company before proceeding with installation. The location of your wood heater in your home will decide how affectively the heat produced will spread throughout your house. Attention to the home design with consideration of natural convection and air circulation should be taken into account when choosing the placement of your heater within the home.

Preparation for Installation Check for damage to the exterior of the fireplace insert (dents should be reported, scratches can be

fixed by applying touch up paint). Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place). The fireplace insert can be lightened by removing the firebricks and baffle (pg 34) - replace before

operation. Packing List

Wood Moisture Meter Touch up paint Bypass tool Gloves

Additional Accessories Needed for Installation Face Surround Panels (see page14)

Additional Requirements for Canada Do not remove bricks or mortar from existing fireplace. This fireplace insert must be installed with a continuous chimney liner of 6” diameter extending from

the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.

Permanently seal any opening between the masonry of the fireplace and the facing masonry. Fireplace insert, or surround panels, may be removed to inspect fireplace insert and fireplace.

Page 160: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

8 Fireplace Insert Installation (for qualified installers only)

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Fireplace Requirements Figure 2 shows the minimum size requirements for the type of fireplace used.

Minimum Fireplace Size

Masonry Fireplace

Z.C. (Metal) Fireplace

a Height (front) 21-1/2" (547mm)

21-1/2" (547mm)

b Height (rear) 19-3/4" (502mm)

19-3/4" (502mm)

c Width (front)* 30-7/8” (785mm)

30-7/8” ** (785mm)

d Width (rear) 18-7/8” (480mm)

20-7/8” ** (531mm)

e Depth *** 19” (483mm)

20" ** (508mm)

f Hearth Depth*** (includes insert depth on hearth plus required hearth extension)

16" (407mm) (US) - - - - - - - - - - - - 18” (458mm) (Canada)

16" (407mm) (US) - - - - - - - - - - - - 18” (458mm) (Canada)

g Hearth Width 44-7/8" (1140mm)

44-7/8" (1140mm)

h Facing Width 46-7/8" (1191mm)

46-7/8" (1191mm)

i Facing Height 39" (991mm)

39" (991mm)

j Mantel Height 41-1/2" (1055mm)

41-1/2" (1055mm)

Figure 2 * Includes 2” (51mm) for power cord installation. ** 1” (26mm) Clearance to fireplace walls is required for ZC Fireplaces. *** This dimension is for a 1-piece panel. Older 3-pieces panels (or 1-piece panels with trim) extend 1-1/4” (32mm) more onto the hearth and 1-1/4” (32mm) less into the fireplace.

Fireplace Altered Tag Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable method). You may wish to place it in a location where it will be covered by the surround panels.

a

c e

f

b

d

h

i

j

g

Non-Combustible Hearth

Combustible Mantel

Non-Combustible Facing

Page 161: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Fireplace Insert Installation (for qualified installers only) 9

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Insert Placement Requirements The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,

doors), 36" (915mm) of the front of the insert (see “q” below). Insert and hearth must be installed on a level, secure floor The minimum clearances, facing, and hearth requirements shown below must be met. Follow the

clearances for the type of fireplace being used – (masonry or zero-clearance-metal). Minimum Clearances

k Sidewall 9" (229mm)

l Side Facing (non-combustible) 9" (229mm)

m Top Facing (non-combustible) 39" (991mm)

n Mantel (combustible) 41-1/2" (1055mm)

o Front Hearth (does not include insert extension “x”) 16" (407mm) (US) - - - - - - - - - - 18” (458mm) (Canada)

p Side Hearth 8" (204mm)

q Front of Insert 36" (915mm)

r Mantel Breastplate (max. 1” (26mm thick)) 39" (991mm)

s Mantel Column (max. 8” (204mm deep)) 9" (229mm)

x Extension Onto Hearth (from front edge of insert) 0" (0mm)

Figure 3

Combustible Top Facing

����������������������������������������������������������������������������������������������������������������������������������������������������������

������������������������������������������������������������������������������

�������������������������������������������������������������������������������������������

Side Wall

Non-Combustible Hearth

Facing

q

lp

o

m

Combustible Mantel

nMax. 1"26mm

rk

s

x

Page 162: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

10 Fireplace Insert Installation (for qualified installers only)

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Masonry Fireplace - Hearth Requirements FLUSH INSTALLATIONS (insert raised less than 7” above combustible floor): The hearth must meet Uniform Building Code (UBC) standards. In the USA the hearth must extend a minimum 16” (407mm) in front of the fireplace insert. In CANADA the hearth must extend a minimum 18” (458mm) in front of the fireplace insert The hearth must extend 8” (204mm) from both sides of the insert. RAISED INSTALLATIONS (insert raised a minimum 7” above floor): If the base of the insert is a minimum 7” (178mm) above the combustible floor (carpet, wood, etc.) the hearth must extend 16” 407mm (USA) / 18” 458mm (CANADA) in front of the insert. The hearth must extend 8” (204mm) from both sides of the insert. The hearth must be non-combustible (cement board, tile, etc.) but does not need to meet an R-value (thermal resistance) or UBC standard.

Zero-Clearance (Metal) Fireplace - Hearth Requirements FLUSH INSTALLATIONS (insert raised less than 7” above combustible floor): The hearth must provide an R-value (thermal resistance) of 2.38 or greater. In the USA the hearth must extend a minimum 16” (407mm) in front of the fireplace insert. In CANADA the hearth must extend a minimum 18” (458mm) in front of the fireplace insert. The hearth must extend 8” (204mm) from both sides of the insert.

RAISED INSTALLATIONS (insert raised a minimum 7” above floor): If the base of the insert is a minimum 7” (178mm) above the combustible floor (carpet, wood, etc.) the hearth must extend 16” 407mm (USA) / 18” 458mm (CANADA) in front of the insert. The hearth must extend 8” (204mm) from both sides of the insert. The hearth must be non-combustible (cement board, tile, etc.) but does not need to meet an R-value (thermal resistance) or UBC standard.

Masonry Fireplace Requirements Chimney must have a stainless steel liner (positive connection). Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired

prior to installation of the insert. Chimney height: 15' (4.5M) minimum; 33' (10M) maximum (measured from base of insert). Entire fireplace, including chimney, must meet local building requirements.

The fireplace insert must be placed on a masonry hearth built to UBC standards.

Zero-Clearance (Metal) Fireplace Requirements Must be manufactured by one of the following manufacturers:

• Marco • Majestic • Heatilator • Preway • Tempco • Superior • Heat N Glo • Lennox • Martin • Monesson

Entire fireplace, including chimney, must meet local building requirements Chimney height: 15' minimum; 33' maximum.

Hearth

Combustible Flooring

Non-Combustible Hearth(Tile, Cement Board, etc.)

USA Min. 16” (407mm)CANADA Min. 18” (458mm)

Combustible Flooring

Min. 7” (153mm)

FLUSH INSTALLATIONS (See details above)

RAISED INSTALLATIONS (See details above)

USA Min. 2”” (51mm)CANADA Min. 1” (26mm)

USA Min. 16” (407mm)CANADA Min. 18” (458mm)

Page 163: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Fireplace Insert Installation (for qualified installers only) 11

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

The damper ("A") and grate ("B") must be removed (see illustration below). The smoke shelf ("C"), internal baffles ("D"), screen ("E"), and metal or glass doors ("F") may be removed (if applicable). The masonry lining ("G"), insulation ("H"), and any structured rigid frame members (metal sides, floor, door frame, face of the fireplace, etc. – "I") may not be removed or altered

The chimney on the ZC fireplace must be listed per UL 127 or ULC 610-M87 for all installations. Any

thermal protection component of the fireplace or chimney must remain in place. The fireplace and chimney must be inspected prior to installation. A NFPA 211 Level II inspection is recommended. Repairs must be made prior to insert installation. The base of the fireplace must be structurally sound and able to support the weight of the insert.

The stainless steel liner must be 6” diameter and extend the full height of the chimney (also called a positive connection or full re-line). This liner must meet type HT (2100°F) requirements per UL 1777 (USA) or ULC S635 with “0” clearance to masonry (Canada). The liner must be attached to the insert flue collar and to the top of the existing chimney.

We recommend using the listed Travis ZC Liner Kit from Duravent (SKU 98900046, 47, or 48). If you do not use this kit, you must use the original ZC chimney cap.

The liner support and cap at the top of the chimney must not reduce air flow for the existing air-cooled chimney system. The Travis ZC Liner Kit includes a cap that meets this provision.

To prevent air from passing up the ZC fireplace chimney (the gap between the liner and chimney) we recommend sealing the area near the damper. Use non-combustible material to seal this area (non-backed fiberglass insulation or kaowool).

The convection air channel on the fireplace must not be blocked. Do not block any louvers, grills, or air passages on the front of the fireplace.

Entire fireplace, including chimney, must meet local building requirements. Permits may be required for installation. Final approval is contingent upon the authority having local jurisdiction. Inform you insurance agent of this fireplace insert.

C

B

F

I

D

E

A

G

H

Page 164: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

12 Fireplace Insert Installation (for qualified installers only)

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Drafting Performance Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance and may damage the heater. Inadequate draft may cause backpuffing into the room and `plugging' of the chimney. Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates excessive draft.

Insert Rollers Two rollers are built into the back edge of the insert. This allows the insert to be rolled into position by lifting the front of the insert and pushing it into position (see Figure 4).

Figure 4

Leveling Bolt Installation MASONRY NOTE: Place a metal plate below the bolts on masonry fireplaces to prevent damage to the floor brick. Two leveling bolts are pre-installed on the insert to allow for proper leveling within the fireplace. To access the bolts, remove the back corner firebricks and cover plates “a” and “b”). The bolts are pre-threaded to a weld-nut on the base of the insert. Use a 3/4” socket wrench to screw the bolts down (clockwise) until the insert is level (see “c”).

SEALING THE COVER PLATE: We recommend sealing the cover plate with furnace cement (place on underside of cover plate). BOLT LENGTH: The included bolts allow approximately 1” of rise. If additional rise is required, use a longer 1/2-13 thread bolt. Make sure the additional bolt length does not interfere with the cover plate.

Figure 5

a

b

c

Page 165: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Fireplace Insert Installation (for qualified installers only) 13

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Flue Installation

INTEGRITY™ Super Stove Starter

INTEGRITY Venting Systems manufactures starter sections in straight or angled configurations to suit your application. They are secured from inside the firebox, making installation much easier. Contact INTEGRITY Venting Systems for additional details: integrityventingsystems.com

Sealing the Flue to the Insert The flue connection is vitally important. To insure proper draft, and to prevent smoke spillage during re-loading, it is crucial for the flue to be sealed with fireplace cement. If an adapter is used, both joints to the liner and to the insert should be sealed. Use a generous amount of fireplace cement at every connection (where the flue connects to the insert and at every joint). In addition, we recommend using non-combustible fiberglass insulation to seal the fireplace enclosure. By sealing the top and bottom of the chimney, and the surround panels, you will be ensuring outside air is not pulled into the chimney.

Three flue brackets and 6 self-drilling screws are included with the insert. Use these components to secure the flue (and/or appliance adapter) to the insert.

The flue (or adapter) may be notched to allow room for the

bypass rod.

Flue (flexible or rigid)

Top of Insert

The liner must be stainless steel connector or flexible vent. Follow the liner manufacturer's insturctions for installation and support.

���������������������

�������

Remove damper or wire it open

Airtight Insulated Clean-Out

Combustible Mantle

Flue Liner

See the section "Insert Placement Requirements" for minimum clearances and hearth required.

�� Cap (prevents water from entering)

Install a non-combustible cover plate to prevent water from entering the chimney

Seal the flue connection to the insert

������������

We recommend using non-combustible fiberglass insulation to seal the fireplace enclosure (chimney top and bottom, and surround panels)

Furnace

Cement

������������

Page 166: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

14 Fireplace Insert Installation (for qualified installers only)

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Insert with Direct Connection (Masonry Fireplace) NOT ALLOWED IN CANADA. A block-off plate or other non-combustible sealing device (e.g. damper adapter) is required. It must seal the chimney to insure smoke does not enter the home while providing the chimney system with sufficient draft.

������������������

����������������

Block-off plate or damper adapter

Removedamperor wire it open

AirtightInsulatedClean-Out

Stainless steel chimney connector must Extend 1' past the block-off plate or to the flue liner

Combustible Mantle

FlueLiner

See the section "Insert PlacementRequirements" for minimum clearances and hearth required.

Surround Panels

Page 167: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Fireplace Insert Installation (for qualified installers only) 15

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Surround Panel Installation Height Width

Small (96100212) 30-1/2” (775mm) 42” (1067mm) Large (96100215) 34” (864mm) 44” (1118mm)

1. Before installing, the insert should be in place with the flue attached. Attach the brackets as shown below, using the screws included in the hardware pack with the insert. Make sure the brackets are flush with the front of the convection chamber.

2. Attach the surround panel as shown below.

HINT: When installing the panel, route the wires through the notch on the bottom of the panel (either side).

Face Installation There are several face options available for this fireplace insert. Refer to the instructions included with your face.

Electrical Requirements Without GreenStart™ Ignitor

Plug the stove into a grounded receptacle supplying a minimum 1.8 amps (115 Volts, 60Hz, 207 watts).

With GreenStart™ Ignitor Plug the stove into a grounded receptacle supplying a minimum 9.8 amps (115 Volts, 60Hz, 1127 watts).

NOTE: A hardwire kit is available from Travis Industries (sku# 97200337).. Contact your dealer for details.

Page 168: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

16 Fireplace Insert Installation (for qualified installers only)

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Re-Routing the Electrical Cord to the Left Side The power cord is connected to the right side of the insert when it leaves the factory. It may be re-routed to the left side following the directions below. Do this procedure before installing the surround panels.

Disconnect the Molex connector and remove the power cord following the directions below.

Connect the power cord to the left side following the directions below.

NOTE: An additional knockout is provided if using the insert wiring kit.Route the power through one hole, the rheostat through the other.

PowerCord

Rheostat Wires

Disconnect the molex connector leading from the power cord.

Use pliers to compress the strain relief from the top and bottom while pulling it out of the hole in the side of the insert.

Remove the power cord.

Leave the rheostat wires in place.

Make sure the power cord is disconnected prior to conducting these steps.

Remove the button plug from the left side.

Re-attach the strain relief to the left side (use pliers to compress the strain relief from the top and bottom while pushing it into the hole).

PowerCord

Attach the molex connector on the power cord to the molex connector on the left side of the insert.

Page 169: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Operating Your Appliance 17

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Safety Notice

If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Read and follow all of the warnings on pages 4 and 5 of this manual.

Before Your First Fire Verify the Installation

Before starting the stove, verify that the stove is properly installed and all of the requirements in this manual have been followed.

Keep all flammable materials 36" away from the front of the stove (drapes, furniture, clothing, etc.).

Curing the Paint Follow the steps below to cure the paint (first fire): a) Open doors and windows in the room to ventilate the heater during the

curing process. b) Vacate the room. The fumes from the initial heating process are non-toxic

but may be unpleasant. c) Slowly bring the heater to a medium burn (400°F/204°C) for 45 minutes.

Then increase the burn temperature to a hot burn (600°F/315°C) for an additional 45 minutes. This will cure the paint.

Door Gasket - The door gasket can adhere to the paint on the front of the heater. To prevent this, carefully open and close the door a few times during the paint curing process.

Carbon Monoxide (CO) Emissions Smoke from wood heaters contain CO. This gas is an indication of incomplete combustion and is detrimental to the environment and to your health. The more visible the smoke, the higher the CO levels. Burning dry wood is the most significant step you can take to reduce CO emissions. It is also important to understand the combustion process so you can burn your heater efficiently. Read the manual thoroughly so that you can operate your heater in the most efficient and clean manner possible.

Over-Firing the Stove DO NOT OVERFIRE THIS HEATER: Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater.

This stove was designed to operate at a high temperature. But due to differences in vent configuration, fuel, and draft, this appliance can be operated at an excessive temperature. If the stove top or other area starts to glow red, you are over-firing the stove. Shut the air control down to low and allow the stove to cool before proceeding.

Over-firing may lead to damage of plated surfaces. If any portion of the heater glows red, it is considered over-firing and will void the warranty.

��������

����

2 to 4 hours

Page 170: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

18 Operating Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Opening the Door

The door becomes hot during use. Use a glove to open the door if the handle is hot.

To prevent smoke from entering the room, open the bypass before opening the door (see following page for directions). You can also open the door a small amount and let air enter the firebox.

Opening the Door

Closing the Door

Page 171: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Operating Your Appliance 19

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Bypass Operation

The bypass control becomes hot during operation - use gloves or a tool to prevent burns.

The bypass controls the flow of smoke inside the heater. When pulled out, smoke goes directly up the flue, creating more draft. When pushed in, the smoke goes around the baffle, utilizing the secondary combustion and making the heater more efficient. When starting or re-loading, pull the bypass out, if necessary. During normal operation, push the bypass in.

Bypass Pushed InUsed for normal operation

Bypass Pulled OutUsed for starting and re-loadinUse the included pull tool

to operate the bypass rod

Page 172: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

20 Operating Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Starting a Fire

The bypass control becomes hot during operation - use gloves or a tool to prevent burns.

Make sure the air control is pushed in and the by-pass pulled out. If additional air is needed, open the door 1/4" during the first five minutes of start-up.

Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire in this stove. Keep all such liquids well away from the stove while it is in use.

DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE. DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. Do not place such fuel within space heater installation clearances or within the space required for charging and ash removal.

If using a fire-starter, use only products specifically designed for stoves - follow the manufacturer's instructions carefully.

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.

If the smoke does not pass up the chimney, ball up one sheet of newspaper, place it in the center of the firebox and light it. This should start the chimney drafting (this eliminates "cold air blockage").

Use plenty of kindling to ensure the stove reaches a proper temperature. Once the kindling is burning rapidly, place a few larger pieces of wood onto the fire.

Starting a “Top-Down Fire” One particularly successful method for starting a fire is to stack several large pieces of wood in the center of the stove (see the illustration to the right). Then place a several wads of newspaper in the center with kindling on top. When you light the newspaper this “top-down” fire will burn its way to the center, igniting the larger pieces. With some practice, this method should work for you.

Page 173: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Operating Your Appliance 21

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Adjusting the Burn Rate Use the air control slider to control the burn rate of the stove. See the illustration below for details.

Approximate Air Control Settings:

Overnight Burn Pulled fully out

Medium Burn Pushed in approx. 3/8” (9.6mm)

High Burn Pushed all the way In

The air control may become hot during operation - use gloves or a tool to prevent burns.

The air control may take several minutes to influence the burn rate. When making adjustments, you may wish to let the stove burn for 10 minutes to gauge performance.

Low Burn

(air control closed)

High Burn

(air control open)

��������

��������

��������

Use the air control to change the burn rate.

Page 174: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

22 Operating Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Understanding Your Heater’s Combustion System This heater uses a dual combustion system detailed below: Primary Combustion: This is the combustion (fire) that takes place directly on the wood. Primary combustion determines how fast the fire burns. Air for primary combustion is supplied through the air control. When you adjust the air control you control the amount of air that reaches the fire and creates primary combustion. The air control supplies air to the air wash (the air holes above the door opening – used to help clean the glass) and through the pilot orifice (center bottom of the door opening). By using the air control, and supplying air through these two openings, you control primary combustion. Secondary Combustion: This is the combustion (fire) that does not contact the wood. Secondary combustion burns the visible emissions or smoke that is not consumed during primary combustion. It takes place at the top of the firebox and can appear as a glowing flame near the secondary air tubes. Items to Consider:

During medium and high burn rates the stove will manage secondary and primary combustion on its own. When the heater is set to a low burn rate more care is needed to ensure the secondary combustion system works properly. Make sure the stove is hot and a good coal bed is established before adjusting your heater to low burn.

Understanding the combustion system in this heater will help minimize the visible emissions this heater releases into the environment. The primary pilot orifice at the center bottom of the door opening is designed to help the secondary combustion at low burn settings. The pilot provides a small amount of air that burns up through the fuel load providing the heat and flame needed for the secondary system to ignite. The air tubes under the baffle need to remain ignited for low burns to be effective.

As you load your heater for a low burn, take care in placing the wood. This will affect how well your secondary system works as the wood is consumed. Do not block the pilot orifice. Stack wood so the pilot air can burn its way up between the pieces, helping your heater burn effectively throughout the low fire. This will reduce the visible emissions your heater produces and increase the amount of heat you get from the wood. If you are unsure how well your heater is burning look at the chimney cap to monitor visible emissions.

Burning Your Heater Starting a Fire: Make sure your air control is all the way open and the by-pass is in the open position. To reduce the amount of smoke when starting your fire, the “Top Down” method described below allows for the cleanest starts. Stack four or five layers of medium-sized kindling 1 to 2” in diameter in a tic tac toe pattern, four pieces per layer with about ½” to 1” spacing between pieces. On top of the kindling stack, place crumpled newspaper and a nest of pencil-sized kindling, this will produce sustained heat at the beginning of the process to help establish draft in the chimney. Light the paper and small kindling on top and let it burn down through the layers of kindling. Using this this method, the door should be able to be closed within approximately two to three minutes after lighting the kindling. If the fire starts to die down, reopen the door and leave it cracked open until the fire takes recovers and becomes established. Never leave your heater unattended if the door is not latched shut. Three to five minutes after closing the door you should be able to shut the by-pass. Again, if the fire starts to die down, open the bypass until the fire is established and the flames are active. Reload the stove with medium sized pieces of cordwood when the kindling pile has burned about three-quarters of the way through. Use just enough wood to establish a good coal bed (approximately 5-7 pieces depending on the size). A hot coal bed is critical to clean combustion of the fuel. We cannot overstate the importance of a hot coal bed before slowing down the burn rate by adjusting the air control. Burn the first full load of cordwood completely through at the high burn rate to get your heater up to a good operating temperature and to establish a hot coal bed before reloading and adjusting the burn rate.

Reloading: When reloading a hot heater set the burn rate on high for at least 15 min before slowing it down. Low Burn: If preparing for an overnight or low burn a longer heat up period may be necessary. Reload the heater full of wood making sure there are air gaps between the wood pieces so the pilot air can burn up through the middle load keeping the secondary combustion system hot and active throughout the burn. After loading, burn the heater on high for at least 15 minutes before setting the air control to low. Excessive creosote buildup (or sooting) in the heater at the end of a low burn signifies that the heater was not hot enough and the wood load was not burned long enough on high after loading before shutting down the air control..

Page 175: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Operating Your Appliance 23

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Blower Operation The blower will turn on once the stove is up to temperature. This is typically 15 to 30 minutes after starting the fire. Follow the directions below to alter the blower speed.

The blower rheostat dial may look different. It does operate in the same fashion.

The blower may be used to affect heat output (i.e.: to reduce heat output, turn the blower down).

Route the power cord in a location where it will not come in contact with the appliance or become hot.

Re-Loading the Stove

Use gloves when reloading wood.

Follow the directions below to minimize smoke spillage while re-loading the stove. 1 Open the air control all the way (push it in). Open the bypass (pull it out). 2 Open the door slightly. Let airflow inside the firebox stabilize before opening the doors fully. 3 Load wood onto the fire.

Overnight Burn Follow the steps below to achieve an overnight burn. 1 Move the air control to high burn and let the stove become hot (burn for approximately 15 minutes). 2 Load as much wood as possible. Use large pieces if possible. 3 Let the stove burn on high for 15 minutes to keep the stove hot, and then turn the air control to

low. 4 In the morning the stove should still be hot, with embers in the coal bed. Stir the coals and load

small pieces of wood to re-ignite the fire, if desired.

Differences in chimney height and draft may lower overall burn times.

Normal Operating Sounds

OFF

Turn the dial all the way counter-clockwise until it clicks off.

HIGH

The high position is all the way counter-clockwise, without clicking off.

LOW

Turn the dial all the way clockwise.

Creaks and Clicks:

The steel may creak or click when the stove heats up

and cools down - this is normal.

Blower Sounds:

The blower will make a slight "humm" as it

pushes air through the stove.

Page 176: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

24 Operating Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Hints for Burning Get the appliance hot before adjusting to low burn Use smaller pieces of wood during start-up and high burns to increase temperature Use larger pieces of wood for overnight or sustained burns Stack the wood tightly together to establish a longer burn Be considerate of neighbors & the environment: burn dry wood only Burn small, intense fires instead of large, slow burning fires when possible Learn your appliance's operating characteristics to obtain optimum performance

Selecting Wood Dry Wood is Key – moisture

content should be less than 25% Dry wood burns hot, emits less

smoke and creates less creosote. Testing Wood Moisture Split wood stored in a dry area will

be fully dry within a year. This insures dry wood. If purchasing wood for immediate use, test the wood with a moisture meter. Some experienced wood burners can measure wood moisture by knocking pieces together and listening for a clear "knock" and not a "thud".

Why Dry Wood is Key

Wet wood, when burned, must release water stored within the wood. This cools the fire, creates creosote, and hampers a complete burn. Ask any experienced wood burner and he or she will agree: dry wood is crucial to good performance.

Wood Cutting and Storage

Wet Wood

Leads To

Leads To

Dry Wood

Leads To

Leads To

Less Heat

More Heat

More Smoke and Creosote

Less Smoke and Creosote

Cut wood to length and chop into quarters.

Store the wood off the ground in a covered area. Allow for airflow around the wood to dry the wood.

Air Flow

Air Flow

Air Flow

Page 177: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Operating Your Appliance 25

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Do Not Burn List This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. DO NOT BURN:

Garbage Lawn clippings or yard waste Materials containing rubber, including tires Materials containing plastic Waste petroleum products, paints or paint thinners, or asphalt products Materials containing asbestos Construction or demolition debris Railroad ties or pressure-treated wood Manure or animal remains Salt water driftwood or other previously salt water saturated materials Unseasoned, “Green” or wet wood Paper products, cardboard, plywood, or particleboard.*

*The prohibition against burning these materials does not prohibit the use of fire starters made from paper, cardboard, saw dust, wax and similar substances for the purpose of starting a fire in an affected wood heater

Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.

Page 178: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

26 Operating Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Troubleshooting

Problem Possible Cause Smoke Enters Room During Start-Up

Open the bypass (pg. 19). Open the air control (pg. 21). Cold Air Blockage - burn a piece of newspaper to

establish a draft. If the flame is not getting enough air, a small crack in

the door is all that is needed.

Kindling Does Not Start - Fire Smolders

Open the bypass (pg. 19). Open the air control (pg. 21). Not enough starter paper - use additional newspaper if

necessary. If the flame is not getting enough air, a small crack in

the door is all that is needed.

Smoke Enters Room While Re-Loading

Open the bypass before opening the door (pg. 19). Open the air control before opening the door (pg. 21). Let the air stabilize before fully opening the door.

Then open the door approximately 1 inch. Let air go into the firebox for a few seconds. Once the smoke appears to be flowing up the chimney consistently, open the door.

Insufficient Draft - Chimney height and outside conditions can negatively affect draft. In these cases a small amount of smoke may enter the home. Adding more piping or a draft-inducing cap may help.

Chimney liner joints are not properly sealed at the insert connection.

Stove Does Not Burn Hot Enough Wood is Wet - see the section "Selecting Wood" on page 24 for details on wood.

Make sure the air control is all the way open. Slide the control back and forth to insure the control is not stuck.

Insufficient Draft - Chimney height and outside conditions can negatively affect draft. In these cases the fire may burn slowly. Adding more piping or a draft-inducing cap may help.

Blower Does Not Run Stove is Not Up to Temperature - This is normal. The blower will come on when the stove is hot - usually 15 to 30 minutes.

Electricity Is Cut to the Blower - Check the household breaker or fuse to make sure it is operable.

Stove Does Not Burn Long Enough

Depending upon wood, draft, and other factors, the burn time may be shorter then stated. Make sure the doors are sealing and not allowing air into the firebox - See the section "Door and Glass Inspection" on page 28 for details.

Check the ash bed for coals. Often, coals are still glowing under a slight bed of flyash. By raking these into a pile you can re-start your stove quickly.

Page 179: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Maintaining Your Appliance 27

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Must replace components with equipment equivalent to the original or approved by the manufacturer.

Failure to properly maintain and inspect your appliance may reduce the performance and life of the appliance, void your warranty, and create a fire hazard.

Establish a routine for the fuel, wood burner and firing technique. Check daily for creosote build-up until experience shows how often you need to clean to be safe. Be aware that the hotter the fire the less creosote is deposited, and weekly cleaning may be necessary in mild weather even though monthly cleaning may be enough in the coldest months. Contact your local municipal or provincial fire authority for information on how to handle a chimney fire. Have a clearly understood plan to handle a chimney fire.

Daily Maintenance (while stove is in use) Remove Ash (if necessary)

Whenever ashes get 3 to 4 inches deep in your firebox or ash pan, and when the fire has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1 inch deep on the firebox bottom to help maintain a hot charcoal bed. Let the stove cool completely before removing ashes (wait at least two hours after the last coal has extinguished). Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, away from all combustible materials, pending final disposal. The ashes should be retained in the closed container until all cinders have thoroughly cooled.

Improperly disposed ashes lead to fires. Hot ashes placed in cardboard boxes, dumped in back yards, or stored in garages, are recipes for disaster.

Wood-burning stoves are inherently dirty. During cleaning have a vacuum ready to catch spilled ash (make sure ash is entirely extinguished).

There are vacuum cleaners specifically made to remove ash (even if the ash is warm). Contact your dealer for details.

Clean the Glass (if necessary)

This appliance has an airwash to keep the glass clean. However, burning un-seasoned wood or burning on lower burn rates leads to dirtier glass (especially on the sides). Do not clean glass with abrasive cleaners. Allow the stove to fully cool before cleaning. Apply glass cleaner or soapy water to the inside of the glass. Wipe with newspaper or a paper towel to clean. For stubborn creosote, dip a moist paper towel or newspaper in cold ash before cleaning. The ash acts as a mild abrasive.

The glass will develop a very slight haze over time. This is normal and will not affect viewing of the fire.

ASHES

���

��������

Page 180: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

28 Maintaining Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Monthly Maintenance (while appliance is in use)

Make sure the appliance has fully cooled prior to conducting service.

Door and Glass Inspection

The door can be lifted off the hinges if extensive repairs are conducted.

The door must form a seal to the firebox for the stove to work correctly. Inspect the door gasket as shown below.

Door Latch Adjustment The door latch should pull the door against the face of the stove (but not so tight as to not allow full handle rotation). If the latch requires adjustment, follow the directions below.

Remove the face. Loosen the bottom nut with a 7/16” wrench (see arrow to the right). Tap the bottom nut inwards, moving the door catch inwards. Tighten the nut and test operation. You may need to repeat this process, either moving the nut inwards or outwards, until the door catch is in the correct position.

Door Handle

Creosote - Formation and Need for Removal When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated 1/8” (3mm), it should be removed to reduce the risk of a chimney fire.

If you are not certain of creosote inspection, contact your dealer or local chimney sweep for a full inspection. Excess creosote buildup may cause a chimney fire that may result in property damage, injury, or death.

Operating this appliance continually at a low burn rate (air starvation) or using green (un-seasoned) wood will increase the formation of creosote.

������������������������������������������������

Severely frayed or thread-bare gasket should be replaced.

Use RTV high temperature silicone to adhere any loose gasket.

If the glass is damaged, replace it - see “Replacement Parts” for details.

������������������������������������������

Page 181: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Maintaining Your Appliance 29

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Yearly Maintenance

Make sure the appliance has fully cooled prior to conducting service.

Touch-Up Paint Included with the owner's pack of this appliance is a can of Stove-Brite® paint. To touch up nicks or dulled paint, apply the paint while the appliance is cool. Sand rusted or damaged areas before preparation (use 120-grit sandpaper). Clean and dry the area to prepare the surface. Wait at least one hour before starting the appliance. The touched up area will appear darker than the surrounding paint until it cures from heat. Curing will give off some fumes while curing – open windows to ventilate.

Cleaning the Air Duct and Blower (if applicable) Use a vacuum to clean the air ducts (channels). This prevents dust from burning and creating odors. The blower should be vacuumed every year to remove any buildup of dust, lint, etc.

Firebrick and Baffle Inspection Firebrick and Baffle Inspection Use the illustration on page ?? as a reference for checking the following items. Make sure the appliance is cool before proceeding. Baffle Firebricks - check the bricks along the ceiling of the firebox to make sure they are intact and have no gaps between them. Slide the bricks to eliminate any gaps. Baffle Supports - make sure the front and back baffle supports in are place and not degraded. Slight scaling or rusting of the metal is normal. Secondary Air Tubes - Check the (4) air tubes to make sure they are intact and not severely deteriorated. Slight scaling or rusting of the metal is normal. Make sure the pins hold the air tubes in place. Floor and Wall Firebricks - replace any severely damaged firebrick along the side or floor of the firebox.

Touch-Up Paint

Remove the face. Use a vacuum cleaner to remove any debris or dust in the convection chamber or near the blower (WARNING: do not touch the blower blades).

Page 182: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

30 Maintaining Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Door Parts

ID # Description Qty. Part # ID # Description Qty. Part # 1 Gasket Cement, 4 oz. 1 99900427 2 Door Gasket, 3/8” x 80” 1 99900429 3 (4) Clips w Screws, Gaskets - Rect

(4) Clips w Screws, Gaskets - Arched 1 1

250-02191 250-02193

4 (2) Clip Gaskets 1 250-02194

5 Glass (w Gasket) – Rectangle 1 250-02183 6 Glass Gasket (1/4” X 76”) 1 250-02184 7 Handle Assembly 1 250-02196 8 Wood Handle w Screw 1 250-01305 9 Glass (w Gasket) – Arched 1 250-02195

Replacing the Glass

The glass must not contact the door retainer or glass clips directly. The glass gasket and glass clip gaskets insulate the glass to prevent cracking. Do not over-tighten the glass clips. Use only 5mm thick neo-ceramic glass.

Lay the glass gasket in the door frame (cut off excess gasket). Place the glass on the gasket. Secure the glass clips to hold the glass in place (make sure the glass clip gaskets are in place).

Replacing the Door Gasket The door gasket inserts into the outer groove of the door retainer. Stove gasket cement holds it in place. Before installing, remove any residual cement. Lay the gasket in place (start at the lower left corner) and cut off any excess gasket (do not stretch the gasket. The cement fully cures with heat from the stove. You may need to open and close the door repeatedly to get the gasket to seat fully.

�����������������������������������

�����������������������������������

4

3

2

1

6

8

7

Rectangular Door

Arched Door

������������������������������������������

������������������������������������������

4

3

2

1

5

6

8

7

9

Page 183: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Maintaining Your Appliance 31

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Blower and Electrical Parts

Make sure to unplug the appliance prior to conducting service.

ID # Description Qty. Part # ID # Description Qty. Part # 1 Left Blower 1 228-10069 2 Right Blower 1 228-10070 3 (4) Blower Grommets w Spacers 1 93005017 4 Rheostat w Nut & Washer 1 250-00302 5 Rheostat Knob 1 250-00369 6 Power Cord 1 250-00316 7 Thermodisk 1 228-30050

6

4

3 5

2

1 7

Page 184: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

32 Maintaining Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Firebox Parts

Baffle Parts ID # Description Qty. Part # ID # Description Qty. Part # 1 Sec. Air Tubes w Pins (all 4) 1 98900249 2 Air Tube Pin (w Screw) 4 250-02186 3 Baffle boards 1 250-04890 4 Baffle Insulation 1 250-04891 5 Damper Plate 1 250-02489 6 Damper Slider 1 250-02492 7 Yoke Damper Extension Rod 1 98900333 8 Damper Extension Rod & Ring 1 250-02493

Baffle Removal 1 Remove the face to prevent damage. Remove the door (lift off hinges). 2 Remove the front two air tubes (see "Air Tube Removal & Replacement" on the following page). 3 Remove the baffle plate and insulation.

8

2

1

3

4

6

5

7

IDB1110

Page 185: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Maintaining Your Appliance 33

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Air Tube Removal & Replacement

Use penetrating oil (WD-40™ or similar) on the bolts before removing them. Let the oil soak in for several minutes before attempting to remove the bolts.

Loosen this bolt 2 or 3 turns (do not remove).Note how the center of the air tube pin

inserts into a hole on the air tube.

3/8" Wrench

With the bolt loosened the air tube can be slid out of the air channel.

The pin will then disengage from the air tube (you may wish to rotate the tube slightly).

Pivot the air tube downwards and slide it out of the air channel on the opposite side.

Air Tube Bolt

Air Tube

Air Tube Pin

VIEW FROM THE FRONT VIEW FROM THE REAR

Air Tube Bolt

Air Channel

Air Channel

AIR TUBE REMOVAL

TUBE SIZINGFront Tube = 25-7/8”Second Tube = 25-7/8”Third Tube = 22-5/8”Back Tube = 19-3/8”

Page 186: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

34 Maintaining Your Appliance

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Brick Removal & Replacement Floor and Side Brick

NOTE: “F” Denotes Full Size Brick (4-1/2” x 9”) ID # Description Qty Part # ID # Description Qty Part #

1 Brick – Cut 9” x 4.5” x 2.34” 2 251-00067 2 Brick – Cut 9” x 2.75” 2 251-00068 3 Brick – Cut 8” x 3.5” x 2.125” 2 251-00066 4 Brick – Cut 9” x 3.5” 2 251-00015 F Brick – Full Size 9” x 4.5” 10 251-00000

Do not pry the brick - they chip and crack easily.

Remove the floor bricks first. The side bricks are pinned in place by the floor firebrick. Clean the firebox prior to replacing the brick. Refer to the section "Baffle Removal" on page 32 for details on removing the baffle bricks.

Page 187: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Limited 7 Year Warranty 35

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Register your TRAVIS INDUSTRIES, INC. Limited 7 Year Warranty online at traviswarranty.com. TRAVIS INDUSTRIES, INC. warrants this appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows:

Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store.

Years 1 & 2 - COVERAGE: PARTS & LABOR Firebox Assembly:

Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber Door Assembly:

Cast Door, Latch Assembly, Glass Retainers Air Control Assembly

Slider Plate, Pressure Plate Ceramic Glass

Glass (breakage from thermal shock) Firebrick

Breakage from thermal shock Accessories

Legs, Pedestal, Blower Re-Installation Allowance

In cases where heater must be removed from home for repairs, a partial cost of re-installation is covered (pre-authorization required)

One-Way Freight Allowance One-way freight allowance on pre-authorized repair done at factory is covered.

Exclusions: Paint, Gasketing

Years 3 THROUGH 5 - COVERAGE: PARTS & LABOR Firebox Assembly:

Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber Air Control Assembly

Slider Plate, Pressure Plate Door Assembly:

Cast Door, Latch Assembly, Glass Retainers One-Way Freight Allowance

One-way freight allowance on pre-authorized repair done at factory is covered. Exclusions: Paint, Gasketing, Accessories (Legs, Pedestal, Panels, Blower), Glass, Firebrick, Re-

Installation Allowance

Years 6 THROUGH 7 - COVERAGE: PARTS Firebox Assembly:

Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber Air Control Assembly

Slider Plate, Pressure Plate Door Assembly:

Cast Door, Latch Assembly, Glass Retainers Exclusions: Paint, Gasketing, Accessories (Legs, Pedestal, Panels, Blower), Glass, Firebrick, Re-

Installation Allowance, One-Way Freight Allowance, Labor Charges

Page 188: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

36 Limited 7 Year Warranty

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

CONDITIONS & EXCLUSIONS 1. This new appliance must be installed by a qualified installer. It must be installed, operated, and maintained at all times in accordance with

the instructions in the Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty. 2. This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized

Travis dealer. 3. Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and,

therefore, not covered under warranty. 4. This warranty does not cover misuse of the stove. Misuse includes over-firing (operation where the connector or stove may glow red) of this

appliance can cause serious damage and will nullify this warranty. Misuse includes use of salt saturated wood, chemically treated wood, or any fuel not recommended in the manual.

5. Damage to the stove due to improper break-in procedures (see manual for proper break in). 6. The salt air environment of coastal areas or a high humidity environment can be corrosive to the castings. These conditions can be corrosive

and can cause the cast iron to rust. This warranty does not cover any damage caused by a salt air or high humidity environment. 7. Damage to the appliance while it is in transit is not covered by this warranty, but is subject to a claim against the common carrier. 8. The warranty, as outlined within this document, does not apply to the chimney components or other non-Travis accessories used in conjunction

with the installation of this product. If in doubt as to the extent of this warranty, contact your authorized Travis retailer before installation. 9. Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings, roof

tops, wind, hills or mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers, etc. 10 This Warranty is void if:

a. The appliance has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals. b. The appliance is subject to submersion in water or prolonged periods of dampness or condensation. c. Any damage to the appliance, combustion chamber, heat exchanger or other components due to water, or weather damage which is

the result of, but not limited to, improper chimney/venting installation. 11. Exclusions to this Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation,

alteration or adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in transit, alteration, or act of God.

12. This warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing, chipped or cracked firebrick, etc. Also excluded is damage to the appliance caused by abuse, improper installation, modification of the appliance, or the use of fuel other than that for which the appliance is configured (use cord wood only).

13. Damage to brass or plated surfaces caused by fingerprints, scratches, melted items, or other external sources left on the surfaces from the use of abrasive cleaners is not covered in this warranty. Damage to the surfaces from over-firing (operation where the steel may glow red) is not covered in this warranty.

14. TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply.

15. This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the Travis appliance without the express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of approval. This warranty does not cover a stove repaired by someone other than a Travis Industries authorized dealer.

16. Any statement or representation of Travis products and their performance contained in Travis advertising, packaging literature, or printed material is not part of this warranty.

17. This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for commercial purposes, it is excluded from this warranty.

18. No dealer, distributor, or similar person has the authority to represent or warrant Travis products beyond the terms contained within this warranty. TRAVIS INDUSTRIES, INC. assumes no liability for such warranties or representations.

19. Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components. 20. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall

remain in effect. 21. This warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether

express or implied, are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.

IF WARRANTY SERVICE IS NEEDED: 1. If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your Travis dealer WITHIN 30 DAYS, giving

them proof of purchase, the purchase date, and the model name and serial number. 2. Travis Industries has the option of either repairing or replacing the defective component. 3. If your dealer is unable to repair your appliance's defect during the warranty period, they will process a warranty claim through TRAVIS

INDUSTRIES, INC. The dealer will require you to supply a copy of your receipt showing the date of the appliance's purchase and the serial number on your appliance. The appliance will then be shipped, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace the appliance free of charge if it is found to be defective in material or workmanship within the time frame stated within this warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges prepaid (years 1 to 3 only) by TRAVIS INDUSTRIES, INC., to your regional distributor, or dealership.

4. Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store.

5. Any appliance or part thereof that is repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the original limited warranty or six(6) months, whichever is longer.

Page 189: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

Listing Information 37

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Listing Label

Page 190: Certification Test Report - Travis Industries Report... · 2020. 6. 22. · Travis Industries, Inc. Model: Medium Flush Wood Insert Report Number: 0028WN123E INDIVIDUAL RUN SUMMARIES

38 Index

© Travis Industries 5/14/2020 - 1531 Med Flush Wood Insert NexGen

Adjusting the Burn Rate ................................... 21 Air Tube Removal & Replacement ................... 33 Baffle Parts ....................................................... 32 Baffle Removal ................................................. 32 Before Your First Fire ....................................... 17 Blower and Electrical Parts .............................. 31 Blower Operation ............................................. 23 Bypass Operation ............................................. 19 Clean the Glass ................................................ 27 Cleaning the Air Duct and Blower .................... 29 Creosote - Formation and Need for Removal .. 28 Curing the Paint ............................................... 17 Daily Maintenance (while stove is in use) ........ 27 Dimensions ........................................................ 6 Do Not Burn List ............................................... 25 Door and Glass Inspection ............................... 28 Door Latch Adjustment ..................................... 28 Door Parts ........................................................ 30 Drafting Performance ....................................... 12 Electrical Requirements ................................... 15 Emissions and Efficiency ................................... 6 Face Installation ............................................... 15 Features ............................................................. 6 Firebox Parts .................................................... 32 Firebrick and Baffle Inspection ......................... 29 Fireplace Altered Tag ......................................... 8 Fireplace Requirements ..................................... 8 Flue Installation ................................................ 13 Hearth Requirements ....................................... 10 Heating Specifications ........................................ 6 Hints for Burning .............................................. 24

Important Information ......................................... 2 Insert Placement Requirements ........................ 9 Insert Rollers .................................................... 12 Installation Options ............................................ 6 Introduction ........................................................ 2 Listing Label ..................................................... 37 Monthly Maintenance (while appliance is in use)

..................................................................... 28 Normal Operating Sounds ............................... 23 Opening the Door ............................................. 18 Over-Firing the Stove ....................................... 17 Overnight Burn ................................................. 23 Packing List ........................................................ 7 Planning the Installation ..................................... 7 Re-Loading the Stove ...................................... 23 Remove Ash (if necessary) .............................. 27 Replacing the Door Gasket .............................. 30 Replacing the Glass ......................................... 30 Re-Routing the Electrical Cord to the Left Side

..................................................................... 16 Safety Notice .................................................... 17 Sealing the Flue to the Insert ........................... 13 Selecting Wood ................................................ 24 Starting a Fire .................................................. 20 Surround Panel Installation .............................. 15 Touch-Up Paint ................................................ 29 Troubleshooting ............................................... 26 Verify the Installation ....................................... 17 Wood Cutting and Storage .............................. 24 Yearly Maintenance ......................................... 29