Certification of the ERA-GLONASS e- call systems/devices ...2 Navigation module Requirements as per...
Transcript of Certification of the ERA-GLONASS e- call systems/devices ...2 Navigation module Requirements as per...
Federal State Unitary Enterprise Radio Research & Development Institute (NIIR)
Testing Center “Omega” – branch of NIIR
Head of technical research center, Alexander Grinko
Certification of the ERA-GLONASS e-call systems/devices for compliance
with requirements of TR CU 018/2011
Potential of the Certification body and
testing laboratory
2
Navigation module Requirements as per GOST R 54620 item 8.1 Testing procedure as per GOST R 55534 (except item 5.16)
Tests are carried out using GNSS signals simulator based on vector generator R&S SMBV-100A
16 technical features are tested; A detailed Operation Manual on carrying out the tests of a vehicle
navigation module of ERA-GLONASS emergency call devices/systems (hereinafter IVS) under GOST R 55534 has dawn up.
3
Navigation module Photo of the workplace for the testing of IVS navigation module
4
Navigation module Working process. Testing of the IVS navigation module under GOST R 55534 on the
domestic manufacturer’s sample.
5
Communication module Requirements as per GOST R 54620 item 8.3 Testing procedure as per GOST R 55533
Tests are carried out using testing equipment Agilent E5515C. When measuring GSM and UMTS radio technologies parameters this device simulates operation of the base station.
39 technical features are tested
6
Communication module Photo of the workplace for the testing of IVS communication module
7
Communication module Working process. Testing of the IVS communication module under GOST R 55533
on the domestic manufacturer’s sample.
8
Tone modem Requirements as per GOST R 54620 item 8.6 Testing procedure as per GOST R 55533
Tests are carried out using broadband tester R&S CMW500. When performing tests this device simulates operation of the GSM/UMTS base station.
9 technical features are tested
9
Functions Photo of the workplace for the IVS communication module functional tests
10
Functions Working process. IVS functional tests under GOST R 55533 on the
domestic manufacturer’s sample.
14 technical features are tested
11
General look of the laboratory for the functions, communication and navigation modules testing
12
Electromagnetic compatibility Requirements as per GOST R 54620 item 13.4 Testing procedure as per GOST R 54618 item 5
7 technical features are tested
13
Electromagnetic compatibility
Resistance of the IVS to the conducted power supply interference (item 5.2.7 and Regulations IEC UN No. 10-03 section 6.8)
Photos of the workplaces for IVS testing on EMC (as per GOST R item 5)
Emission level of the self-interference caused by IVS to the in vehicle network (item 5.2.8 and Regulations IEC UN No. 10-03 section 6.9)
14
Electromagnetic compatibility
IVS resistance to the interference in control and signal circuits (item 5.2.9)
Photos of the workplaces for testing of the vehicles ERA-GLONASS e-call system on EMC (as per GOST R item 5)
Radio interference voltage at the IVS supply connectors (item 5.2.11)
15
Electromagnetic compatibility
IVS resistance to impact of the electrostatic discharge (item 5.2.10)
Photos of the workplaces for testing of the vehicles ERA-GLONASS e-call system on EMC ( as per GOST R 54618 item 5)
Electromagnetic field intensity, caused by IVS (narrowband and broadband interference) (item 5.2.12 and Regulations IEC UN No.10-03 section 6.5, 6.6)
16
Electromagnetic compatibility Photos of the workplaces for testing of the vehicles ERA-GLONASS e-call system on EMC ( as
per GOST R 54618 item 5)
IVS resistance to electromagnetic radiation within the frequency range of 20 to 2000 MHz (item 5.2.13 and Regulations IEC UN No. 10-03, section 6.7)
a) in conditions of the free field of 80 to 1000 MHz; b) in conditions of the free field of 1000 to2000 MHz;c) within the 800-mm stripe system of 20 to 80 MHz.
a)
b)
c)
17
Resistance to the climatic exposures
Requirements as per GOST R 54620 item13.2 Testing procedure as per GOST R 54618 item 6
Working process. Testing of the vehicles ERA-GLONASS e-call system on resistance to the climatic exposures under GOST R 54618 on the domestic manufacturer’s sample.
10 parameters are tested
18
Resistance to the climatic exposures Photos of the workplaces for testing of the vehicles ERA-GLONASS e-call system on resistance to
the climatic exposures
19
Resistance to the mechanical impact
Requirements as per GOST R 54620 item 13.3 Testing procedure as per GOST R 54618 item 7
Working process. Testing of the vehicles ERA-GLONASS e-call system on resistance to the mechanical impact under GOST R 54618 on the domestic manufacturer’s sample.
7 parameters are tested
20
Photos of the work places for the ERA-GLONASS emergency-call systems testing for resistance to mechanical impact
Resistance to mechanical impact
211
Thank you for your kind attention
This presentation is a property of NIIR. All its components: general look and content are protected by the law of Russian Federation on copyright
as well other laws governing the intellectual property right.Except for the cases when the written consent of NIIR exists, not even a single part hereof may be copied or used in any other way.
Rev. 2.0