CERTIFICATE OF ANALYSIS · 2020-01-31 · CERTIFICATE OF ANALYSIS ISO/IEC 17025:2017 ACCREDITATION...
Transcript of CERTIFICATE OF ANALYSIS · 2020-01-31 · CERTIFICATE OF ANALYSIS ISO/IEC 17025:2017 ACCREDITATION...
Reporting Limit 10 ppm *Total CBD = CBD + CBDA x 0.877 N/D - Not Detected, B/LOQ - Below Limit of Quantification
CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104
Order #: 44073Order Name: Organic CBDMCT OilBatch#: 1092019MCT12Received: 12/17/2019Completed: 12/20/2019
Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) [email protected]
Sample
0.243% D9-THC
7.017% Total CBD
Cannabinoids TestSHIMADZU INTEGRATED UPLC-PDAGSL SOP 400 PREPARED: 12/17/2019 13:04:18 UPLOADED: 12/18/2019 08:58:11 Cannabinoids LOQ weight(%) mg/gD9-THC 10 PPM 0.243% 2.430THCA 10 PPM N/D N/DCBD 10 PPM 7.004% 70.041CBDA 20 PPM 0.015% 0.151CBDV 20 PPM 0.026% 0.265CBC 10 PPM 0.482% 4.818CBN 10 PPM N/D N/DCBG 10 PPM 0.117% 1.174CBGA 20 PPM N/D N/DD8-THC 10 PPM N/D N/DTHCV 10 PPM N/D N/D
TOTAL D9-THC 0.243% 0.243%TOTAL CBD* 7.017% 70.173TOTAL CANNABINOIDS 7.887% 78.879
Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.
PESTICIDE ANALYSIS:GSL SOP 401 PREPARED: 12/17/2019 12:54:16 UPLOADED: 12/18/2019 15:30:03
N/D = Not Detected, A/LOQ = Above LOQ Level, B/LOQ = Below LOQ Level, B/LOD = Below LOD Level
CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104
Order #: 44073Order Name: Organic CBDMCT OilBatch#: 1092019MCT12Received: 12/17/2019Completed: 12/20/2019
Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) [email protected]
GCMS-MS - Shimadzu GCMS-TQ8040
Pesticide Action Level(ppm)
Results(ppm)
LOQ(ppm)
LOD(ppm)
FIPRONIL 0.100 N/D 0.003 0.001
Pesticide Action Level(ppm)
Results(ppm)
LOQ(ppm)
LOD(ppm)
FLUDIOXONIL 0.100 N/D 0.003 0.001
LCMS-MS - Shimadzu LCMS-8060
Pesticide Action Level(ppm)
Results(ppm)
LOQ(ppm)
LOD(ppm)
ABAMECTIN B1A 0.100 N/D 0.005 0.001ACEPHATE 0.100 N/D 0.001 0.001ACEQUINOCYL 0.100 N/D 0.001 0.001ACETAMIPRID 0.100 N/D 0.005 0.001ALDICARB 0.100 N/D 0.005 0.001AZOXYSTROBIN 0.100 N/D 0.001 0.001BIFENAZATE 0.100 N/D 0.005 0.001BIFENTHRIN 3.000 N/D 0.005 0.001BOSCALID 0.100 N/D 0.005 0.001CARBARYL 0.500 N/D 0.003 0.001CARBOFURAN 0.100 N/D 0.001 0.001CHLORANTRANILIPROLE 10.000 N/D 0.005 0.005CHLORPYRIFOS 0.100 N/D 0.001 0.001CLOFENTEZINE 0.100 N/D 0.001 0.001DAMINOZIDE 0.100 N/D 0.005 0.001DIAZANON 0.100 N/D 0.001 0.001DICHLORVOS 0.100 N/D 0.005 0.001DIMETHOATE 0.100 N/D 0.001 0.001DIMETHOMORPH 2.000 N/D 0.005 0.001ETHOPROPHOS 0.100 N/D 0.001 0.001ETOFENPROX 0.100 N/D 0.001 0.001ETOXAZOLE 0.100 N/D 0.010 0.005FENHEXAMID 0.100 N/D 0.005 0.001FENOXYCARB 0.100 N/D 0.005 0.001FENPYROXIMATE 0.100 N/D 0.001 0.001FLONICAMID 0.100 N/D 0.025 0.010HEXYTHIAZOX 0.100 N/D 0.005 0.001IMAZALIL 0.100 N/D 0.005 0.001
Pesticide Action Level(ppm)
Results(ppm)
LOQ(ppm)
LOD(ppm)
IMIDACLOPRID 5.000 N/D 0.005 0.001KRESOXIM-METHYL 0.100 N/D 0.010 0.005MALATHION 0.500 N/D 0.005 0.001METALAXYL 2.000 N/D 0.001 0.001METHIOCARB 0.100 N/D 0.005 0.001METHOMYL 1.000 N/D 0.001 0.001MEVINPHOS 0.100 N/D 0.001 0.001MYCLOBUTANIL 0.100 N/D 0.005 0.001NALED 0.100 N/D 0.005 0.001OXAMYL 0.500 N/D 0.001 0.001PACLOBUTRAZOL 0.100 N/D 0.005 0.001PERMETHRINS 0.500 N/D 0.005 0.001PHOSMET 0.100 N/D 0.005 0.001PIPERONYLBUTOXIDE
3.000 N/D 0.001 0.001
PRALLETHRIN 0.100 N/D 0.005 0.005PROPICONAZOLE 0.100 N/D 0.010 0.005PROPOXUR 0.100 N/D 0.001 0.001PYRETHRINS(PYRETHRIN I)
0.500 N/D 0.005 0.005
PYRIDABEN 0.100 N/D 0.005 0.001SPINETORAM 0.100 N/D 0.001 0.001SPINOSAD 0.100 N/D 0.001 0.001SPIROMESIFEN 0.100 N/D 0.005 0.001SPIROTETRAMAT 0.100 N/D 0.001 0.001SPIROXAMINE 0.100 N/D 0.001 0.001TEBUCONAZOLE 0.100 N/D 0.005 0.001THIACLOPRID 0.100 N/D 0.001 0.001THIAMETHOXAM 5.000 N/D 0.001 0.001TRIFLOXYSTROBIN 0.100 N/D 0.001 0.001
Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.
CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104
Order #: 44073Order Name: Organic CBDMCT OilBatch#: 1092019MCT12Received: 12/17/2019Completed: 12/20/2019
Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) [email protected]
Microbial Analysis:PCR - Agilent AriaMX
Microbial Analysis GSL SOP 406 Uploaded: 12/20/2019 17:35:55
Test Test MethodUsed Device Used LOD Allowable Criteria Actual
Result Pass/Fail
STEC E.COLI* USP 61/62† ARIAMX PCR 2 COPIES OF DNA PRESENCE / ABSENTBELOW
LODPASS
SALMONELLA* USP 61/62† ARIAMX PCR 5 COPIES OF DNA PRESENCE / ABSENTBELOW
LODPASS
ASPERGILLUS USP 61/62† ARIAMX PCR ASP_LOD*** PRESENCE / ABSENTBELOW
LODPASS
† USP 61 (enumeration of bacteria TAC, TYM, and ENT/Coliform), USP 62 (identifying specific species E.coli Aspergillus etc) * STEC and Salmonella run as Multiplex *** Flavus = 2 Copies of DNA / Fumigatis = 2 Copies of DNA Niger = 20 Copies of DNA / Terrus = 10 copies of DNA
Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.
CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104
Order #: 44073Order Name: Organic CBDMCT OilBatch#: 1092019MCT12Received: 12/17/2019Completed: 12/20/2019
Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) [email protected]
Heavy Metals Analysis:ICP-MS - Shimadzu ICPMS-2030GSL SOP 403 Uploaded: 12/17/2019 19:41:53
Metal Action Level (ppb) Result (ppb)ARSENIC (AS) 200 B/LOQCADMIUM (CD) 200 B/LOQMERCURY (HG) 100 B/LOQLEAD (PB) 500 B/LOQ
Lower Limit of Quantitation (LOQ) is 75 ppb
Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.