Ceragon 1500HP Description Manual
-
Upload
francisco-dariem-tineo-mateo -
Category
Documents
-
view
205 -
download
11
description
Transcript of Ceragon 1500HP Description Manual
FibeAir® 1500HP
Advanced Long Haul High Power Radio System
Version 7.0 May 2009
Notice This document contains information that is proprietary to Ceragon Networks Ltd.
No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd.
This document is provided as is, without warranty of any kind.
Registered TradeMarks Ceragon Networks®, FibeAir®, and CeraView® are registered trademarks of Ceragon Networks Ltd.
Other names mentioned in this publication are owned by their respective holders.
TradeMarks CeraMapTM, ConfigAirTM, PolyViewTM, EncryptAirTM, CeraMonTM, EtherAirTM, and MicroWave FiberTM, are trademarks of Ceragon Networks Ltd.
Other names mentioned in this publication are owned by their respective holders.
Statement of Conditions The information contained in this document is subject to change without notice.
Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.
Information to User Any changes or modifications of equipment not expressly approved by the manufacturer could void the user’s authority to operate the equipment and the warranty for such equipment.
Copyright © 2009 by Ceragon Networks Ltd. All rights reserved.
Corporate Headquarters: Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: [email protected] www.ceragon.com
European Headquarters: Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: [email protected]
North American Headquarters: Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: [email protected]
APAC Headquarters: Ceragon Networks APAC (S'pore) Pte Ltd 100 Beach Road #27-01/03 Shaw Towers Singapore 189702 Tel.: 65 65724170 Fax: 65 65724199
Contents Introduction .................................................................................................................1
References & Standards.............................................................................................2
Product Overview........................................................................................................3
The Complete Solution ...............................................................................................4
Main Features ..............................................................................................................6
Applications.................................................................................................................7
Space Diversity Concept ............................................................................................8
IF Combining Mechanism...........................................................................................8
Base Band Switching..................................................................................................8
Configurations.............................................................................................................9
Typical Configuration Descriptions ........................................................................10
Environmental Conditions Standard Compliance .................................................22
Safety Conditions Standard Compliance................................................................22
FibeAir 1500HP Components...................................................................................23
Management ..............................................................................................................26
FibeAir 1500HP Specifications ................................................................................27
Appendix: Frequency Channels ..............................................................................29
FibeAir® 1500HP - Advanced High Power Radio System 1
Introduction
Widespread popular demand for wireless connectivity has greatly increased in recent years as public and private sectors strive to meet the diverse and growing demand for capacity-rich applications.
In the wireless communication industry, radios capable of longer distances, excellent performance, growth-on-demand, and lower cost of ownership constitute the optimal network infrastructure building blocks.
The advantages of wireless networks, including minimal operational costs, faster and easier installation, efficient capacity upgrade, and high-quality data delivery, have made them the medium of choice for both operators and businesses alike.
With those demands in mind Ceragon introduces FibeAir 1500HP, the latest in the FibeAir family of products.
FibeAir 1500HP is a high transmit power RFU (Radio Frequency Unit). It was designed to enable high quality wireless communication in the most cost-effective way, including an ultra high power transmitter that reaches longer distances and uses smaller antennas.
Designed for maximum flexibility and transmission efficiency, FibeAir 1500HP includes two receivers and one transmitter in a single transceiver unit. This design gives it a built-in Diversity capability using an innovative digital multi-mode IF combiner, which increases the reliability of the link. In a 1+1 Hot Standby or N+1 configuration with Space Diversity, if a hardware failure occurs, the Diversity functionality will not be affected.
FibeAir 1500HP is installed in a Split-Mount configuration. In this installation, the RFU is installed near the antenna, with a single cable connecting between the RFU and IDU.
Thus, FibeAir 1500HP, with its built-in Diversity functionality and installation type flexibility, presents a comprehensive, efficient, and budget-saving wireless network building block that equips operators with a true competitive edge.
FibeAir® 1500HP - Advanced High Power Radio System 2
References & Standards
[1] EN 300 234: “Transmission and Multiplexing (TM); Digital Radio Relay Systems (DRRS); High capacity DRRS carrying 1xSTM-1 / OC-3 signals and operating in frequency bands with about 30 MHz channel spacing and alternated arrangements”.
[2] EN 300 385: "Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for fixed radio links and ancillary equipment".
[3] ETS 300 019: "Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment".
[4] ETS 300 132-2: "Equipment Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 2: Operated by direct current (dc)".
[5] ITU-R Recommendation F.1191: "Bandwidths and unwanted emissions of digital radio-relay systems".
[6] ITU-R Rec. F.383-6: "Radio-frequency channel arrangements for high capacity radio-relay systems operating in the lower 6 GHz band.
[7] ITU-R Rec. F.384-7: " Radio-frequency channel arrangements for medium and high capacity analogue or digital radio-relay systems operating in the upper 6HGHz band
[8] FCC 101.147 [7] " Radio-frequency channel arrangements for radio-relay systems operating in upper 6HGHz band
[9] ITU-R Rec. F.385-6: " Radio-frequency channel arrangements for radio-relay systems operating in the 7 GHz band
[10] ITU-R Rec. F.386-6: " Radio-frequency channel arrangements for medium and high capacity analogue or digital radio-relay systems operating in the 8 GHz band
[11] ITU-R Rec. F.387-8: " Radio-frequency channel arrangements for radio-relay systems operating in the 11 GHz band
[12] ITU-T Recommendation G.703 (1991): "Physical/electrical characteristics of hierarchical digital interfaces".
[13] ITU-T Recommendation G.707 (1996): "Network node interface for the synchronous digital hierarchy (SDH / SONET)".
[14] CEPT/ERC 14-01E " Radio-frequency channel arrangements for radio-relay systems operating in the 6LGHz band
[15] FCC 101.147 [6] " Radio-frequency channel arrangements for radio-relay systems operating in the 11GHz band
FibeAir® 1500HP - Advanced High Power Radio System 3
Product Overview
Ceragon’s FibeAir 1500HP supports multiple capacities, frequencies, modulation schemes, and configurations for various network requirements. Its RF transceiver units operate in the frequency range of 6-11 GHz.
FibeAir 1500HP capacities can be upgraded from 45 Mbps up to N x 155 Mbps.
For long distance links and backbone requirements, FibeAir 1500HP offers Space Diversity functionality. Each transceiver can contains two receivers and one transmitter, which enable built-in diversity capability.
Built in Diversity in each transceiver increases the reliability of the link. In a 1+1/2+2 Hot Standby or N+1 configuration with Space Diversity, if a hardware failure occurs, the Diversity will not be affected.
FibeAir 1500HP is installed in a Split-Mount configuration, as shown in the following example illustration.
2+0 Configuration
FibeAir® 1500HP - Advanced High Power Radio System 4
The Complete Solution
The FibeAir 1500HP RFU works together with FibeAir 1500P/IP-MAX, 3200T,and 640P IDUs, which are Ceragon’s modular network connectivity IDUs designed to meet growing market demands for increased spectral-efficient systems.
FibeAir 1500P is designed to deliver double the capacity using a single 28 MHz channel. The system is easy to install, offers a variety of interface possibilities, and represents a cost-effective alternative to fiber.
FibeAir IP-MAX is Ceragon’s comprehensive Ethernet solution that offers Fast and Gigabit Ethernet wireless transmission with fiber-like quality.
FibeAir 3200T is a high capacity N+1 trunk radio system that was designed to support multiple capacities, frequencies, modulation schemes, and configurations for various network requirements.
FibeAir 640P is Ceragon’s high capacity PDH radio designed for seamless upgrade from medium to high capacity, with a built-in Fast Ethernet port and switch.
FibeAir 1500HP RFUs together with the different FibeAir IDUs provide a powerful, reliable, and comprehensive solution for a variety of wireless network scenarios and requirements.
FibeAir 1500HP RFU
FibeAir 1500P IDU FibeAir IP-MAX IDU
FibeAir 640P IDU FibeAir 3200T IDU
FibeAir IP-10
FibeAir® 1500HP - Advanced High Power Radio System 5
Frequency Bands
The frequency band of each radio is described in the following table.
Frequency Band
Frequency Range (GHz)
Channel Bandwidth ITU-R Standard
5.925 to 6.425 29.65 MHz ITU-R F.383 L6 GHz
5.925 to 6.425 10 MHz to 30 MHz FCC Part 101.147 (i)
U6 GHz 6.425 to 7.100
6.525 to 6.875
20 MHz to 40 MHz
10 MHz , 40MHz
ITU-R F.384
FCC Part 101.147 (k7)
7.425 to 7.900 14 MHz to 28 MHz ITU-R F.385 Annex 4
7.425 to 7.725 28 MHz ITU-R F.385 Annex 1 7 GHz
7.110 to 7.750 28 MHz ITU-R F.385 Annex 3
7.725 to 8.275 29.65 MHz ITU-R F.386 Annex 1
8.275 to 8.500 14 MHz to 28 MHz ITU-R F.386 Annex 3 8 GHz
7.900 to 8.400 14 MHz to 28 MHz ITU-R F.386 Annex 4
11 GHz 10.700 to 11.700 10 MHz to 30 MHz or 40 MHz
ITU-R 387-8
FCC 101.147 [6]
FibeAir® 1500HP - Advanced High Power Radio System 6
Main Features
Operates in the frequency range of 6-11 GHz
Installation type: Split-Mount 1+0, 1+1, 2+2 to N+0/N+1, using the same RFU
High transmit power: 29/30 dBm
Configurable Capacity: from 40 Mbps to N+1 x 155 Mbps
Configurable Modulation: QPSK, 16, 32, 64, 128, 256 QAM
Configurable Channel bandwidth: 10/14/20/28/30/40 MHz
Innovative digital IF combiner
Two receivers and one transmitter in a single transceiver unit, for built-in Diversity capability
Variety of interfaces for TDM & IP
Built-in XPIC (Cross Polarization Interference Canceller) Co-Channel Dual Polarized (CCDP) feature for double transmission capacity, and more bandwidth efficiency
ATPC (Automatic Tx Power Control)
Simple and flexible installation
Easy system expansion to N+1 carriers
Compliant with ETSI, FCC, ITU-T, ITU-R, and IEEE standards and frequency plans, for worldwide operation
Compatible with 1500P/IP-MAX, 640P, and 3200T IDUs
FibeAir® 1500HP - Advanced High Power Radio System 7
Applications FibeAir 1500HP can be used for a variety of applications, as a flexible and cost-effective long haul solution.
The following are examples of applications for which FibeAir 1500HP is optimally suited.
Long Distance Connectivity For both fixed line and mobile operators, FibeAir 1500HP provide long distance connectivity. Use of lower frequencies, which require high transmit power, Space Diversity, and multiple carriers, enables FibeAir 1500HP to facilitate backbone long haul network building.
Mobile and Fixed Infrastructure FibeAir 1500HP is an optimal solution for expansion mobile cellular networks that require high capacity due to an increase in subscribers, cell sites, and data rich applications. It offers smooth migration from existing PDH to SONET/SDH network functionality and to next generation ATM/IP, using different capacities: DS3, FE/GBE, and up to N+1 x STM-1/OC-3. With its reliable fiber-like transmission/receiving quality and protection capabilities, FibeAir 1500HP is a dependable telecommunications solution for different network topologies, such as ring, mesh, chained, and star, which require both accuracy and stability. FibeAir 1500HP can be deployed in an ATM-based or SDH/SONET backbone, providing high capacity to carry Digital Video Broadcast services and data. Since FibeAir 1500HP deployment is fast and easy, it can provide ATM-based services quickly and efficiently to public and private end users. 1500HP, with its unique flexibility structure and branching connections, enables easy upgrade for mobile networks with single or dual carrier capacity to N+1 carriers.
Broadcast Networks The scalability and modularity of FibeAir 1500HP wireless solutions are ideal for effectively building and expanding contribution and distribution digital broadcast networks. Deployed in an ATM-based SDH backbone or IP network, FibeAir 1500HP offers reliable high quality transmission of Digital Video Broadcast signals and data. Applications include TV, radio, telemedicine, and others.
Private Networks FibeAir 1500HP solutions provide transparent high capacity connection of enterprise LAN and PBX systems, which reduces communication costs, operating expenses, and maintenance requirements. Wireless high capacity connectivity is ideal for a variety of private networks and enterprises, such as utility operators, corporate facilities, education campuses, hospitals, banks, and others. Applications include LAN Ethernet connectivity, VoIP, client-server applications, remote storage, video conferencing, TDM T1/E1 services, network infrastructure redundancy, and others.
Government and Emergency Services Ceragon’s FibeAir 1500HP quality product meets the high-level demands of governmental customers by providing rapidly deployed secure and long distance data transmission, in a single compact, light weight, and scaleable solution. Applications include disaster recovery, temporary installations, broadband voice, data and video services, and surveillance and monitoring.
FibeAir® 1500HP - Advanced High Power Radio System 8
Space Diversity Concept In long distance wireless links, multipath phenomenon commonly exist, whereby fading occurs over time, space, and frequency.
The 1500HP RFU provides two types of Space Diversity optimizations, which are ideal solutions for the multipath phenomenon:
IF Combining
BBS (Base Band Switching)
Note that there are two types of RFUs, one with and one without support for space diversity. The RFUs have different part numbers, and are characterized as follows:
RFU with dual receiver (supports Space Diversity using IF combining)
RFU with single receiver (does not support Space Diversity using IF combining)
Both RFUs support Space Diversity BBS (Base Band Switching).
IF Combining Mechanism The RFU includes an IF combining mechanism, which sums the signals received from both antennas, to improve signal quality.
FibeAir 1500HP IF combining is performed by an innovative digital optimization algorithm. When distortion occurs, it is measured in both receiver paths, a new combined signal is produced, which improves the system gain by up to 3 dB.
The delay calibration for the diversity waveguide is done automatically via the NMS.
Each RFU has built-in space diversity functionality, with one transmitter and two receivers. The receivers receive two different signals from two antennas, which are installed 10-20 meters apart.
Base Band Switching FibeAir 1500HP can operate with base band Space Diversity (as with FibeAir 1500P and 1500SP ODUs).
With Diversity performed in the indoor (baseband), the modem will switch to the other RF signal when interference occurs, and will return to the main signal when the interference is gone. In this way, the system performs optimum signal receiving by switching to the best signal performance.
FibeAir® 1500HP - Advanced High Power Radio System 9
Configurations
FibeAir 1500HP supports the following configurations:
Unprotected
1+0 to N+0 - Data is transmitted through N channels, without redundancy (protection).
Hot Standby
The Hot Standby system includes the following configurations:
Two RFUs use the same RF channel connected via a coupler, whereby one channel transmits and the other acts as a backup (standby).
Hot Standby Frequency Diversity - Two RFUs use different RF channels, whereby both RFUs transmit on different frequencies. The receive signal is generated by one RFU, and hitless switching to the second RFU will be performed if a failure or signal degradation occurs.
Hot Standby with two antennas - Two RFUs are connected to two different antennas. This configuration features Space Diversity, whereby the diversity is achieve in the indoor unit (known as Space Diversity Base-Band Switching).
N+1 Frequency Diversity
N+1 - Data is transmitted through N channels and an additional (+1) frequency channel, which protects the N channels. The +1 channel can carry the data of one of the N carriers if a failure or dignal degradation occurs.
Note: Space Diversity can be used in each of the configurations
FibeAir® 1500HP - Advanced High Power Radio System 10
Typical Configuration Descriptions 1+0 Configuration
1+0 SD Configuration
B.L W.G
M.P
S.P
1+0 SDM.AD.AM.AD.A
0.5dB0dB1.5/2.5dB*
N/AN/A
N/AN/A
0dB
* Coax Cable 3.5/5dB
Item QtyRFU 1OCB SD Type 1 1Pole Mount 150ohm Termination 1Short 1Flex WG 1.2m 1SP Antenna 2WG to N-Type Adap.Kit 1Coaxial Cable (m) 12N-Type connector 2IDC + Chassis 1IDM-155 1
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
50 ohm
RFU
Eliptical WG or Coax Cable
Flexible WG
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
Flexible WG
B.L W.G
M.P
S.P
1+0M.AD.AM.AD.A
0dBN/A N/AN/AN/A
N/AN/A
Item QtyRFU 1OCB Type 1 1Pole Mount 1Short 3Flex WG 1.2m 1SP Antenna 1IDC + Chassis 1IDM-155 1
0.5dB
FibeAir® 1500HP - Advanced High Power Radio System 11
1+1 SD Configuration
B.L W.G
M.P
S.P
1+1 SDM.AD.AM.AD.A
1.4/1.6dB 0.5dB
6/6.4dB 0.5dB1.4/1.6dB 1.5/2.5dB*
* Coax Cable 3.5/5dB
6/6.4dB 1.5/2.5dB*
Item QtyRFU 2OCB SD Type 2 2Pole Mount 1Short 250ohm Termination 2Coupler Type 1 2Flex WG 1.4m 1SP Antenna 2WG to N-Type Adap.K 1Coaxial Cable (m) 12N-Type connector 2IDC + Chassis 1IDM-155 2Protection Kit 1
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
RFU
50 ohm
50 ohm
OCBtype 2
Flexible WG
Eliptical WG or Coax Cable
1+1 HSB Configuration
B.L W.G
M.P
S.P
1+1 HSBM.AD.AM.AD.A
1.4/1.6dB 0.5dBN/A
N/A
N/A
N/A6/6.4dB 0.5dB
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
RFU
OCBtype 2
Flexible WG
Item QtyRFU 2OCB Type 2 2Pole Mount 1Short 6Coupler Type 1 1Flex WG 1.4m 1SP Antenna 1IDC + Chassis 1IDM-155 2Protection Kit 1
FibeAir® 1500HP - Advanced High Power Radio System 12
B.L W.G
M.P
S.P
1+0 FDM.AD.AM.AD.A
0.5dB 0.5dBN/A N/AN/AN/A
N/AN/A
1+1 FD Configuration
Item QtyRFU 2OCB Type 1 1OCB Type 2 1Pole Mount 150ohm Termination 1Short 4U Bend WG Type 1 1Flex WG 1.2m 1SP Antenna 1IDC + Chassis 1IDM-155 2Protection Kit 1
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f3
RX f3
RX f3
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
50 ohm
Flexible WG
B.L W.G
M.P
S.P
1+0 FD/SDM.AD.AM.AD.A
0.5dB0.5dB1.5/2.5dB*
N/AN/A
N/AN/A
0.5dB
* Coax Cable 3.5/5dB
Item QtyRFU 2OCB SD Type 1 1OCB SD Type 2 1Pole Mount 150ohm Termination 2U Bend WG Type 1 2Flex WG 1.2m 1SP Antenna 2WG to N-Type Adap.Kit 1Coaxial Cable (m) 12N-Type connector 2IDC + Chassis 1IDM-155 2Protection Kit 1
1+1 FD/SD Configuration
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f3
RX f3
RX f3
OCBtype 2
8GHz RFU
U bends WG
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
8GHz RFU
50 ohm
50 ohm Eliptical WG or
Coax Cable
Flexible WG
FibeAir® 1500HP - Advanced High Power Radio System 13
1+1 SD BBS Configuration
B.L W.G
M.P
S.P
1+0 SD BBSM.AD.AM.AD.A
0dB 0.5dB
N/AN/A
N/AN/A
0dB 0.5dB
Item QtyRFU 2OCB Type 1 2Pole Mount 2Short 6Flex WG 1.2m 2SP Antenna 2IDC + Chassis 1IDM-155 2Protection Kit 1
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
Main antenna
Diversity antenna
Flexible WG
Flexible WG
FibeAir® 1500HP - Advanced High Power Radio System 14
2+0 DP Configuration
2+0 SD DP Configuration
B.L W.G
M.P
S.P
2+0 SD DPAM.AD.AM.AD.A
0.5dB0dB1.5/2.5dB*
N/AN/A
N/AN/A
0dB
* Coax Cable 3.5/5dB
B.L W.G
M.P
S.P
2+0 DPAM.AD.AM.AD.A
0dB 0.5dBN/A N/AN/AN/A
N/AN/A
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype
1
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype
1
RFU
Flexible WG
Item QtyRFU 2OCB Type 1 2Pole Mount 1Short 6Flex WG 1.2m 2DP Antenna 1XPIC cable 3m long 1IDC + Chassis 1IDM-155 2
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
50 ohm
50 ohm
Eliptical WG or Coax Cable
Flexible WG
Item QtyRFU 2OCB SD Type 1 2Pole Mount 150ohm Termination 2Short 2Flex WG 1.2m 2DP Antenna 2WG to N-Type Adap.Kit 2Coaxial Cable (m) 24N-Type connector 4XPIC cable 3m long 1IDC + Chassis 1IDM-155 2
FibeAir® 1500HP - Advanced High Power Radio System 15
Item QtyRFU 2OCB SD Type 1 1OCB SD Type 2 1Pole Mount 150ohm Termination 2U Bend 2Flex WG 1.2m 1SP Antenna 2WG to N-Type Adap. Kit 1Coaxial Cable (m) 12N-Type connector 2IDC + Chassis 1IDM-155 2
Item QtyRFU 2OCB SD Type 1 1OCB SD Type 2 1Pole Mount 150ohm Termination 1Short 4U Bend 1Flex WG 1.2m 1SP Antenna 1IDC + Chassis 1
FibeAir® 1500HP - Advanced High Power Radio System 16
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
RFU
OCBtype 2
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1'
RX f1'
RX f1'
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1'
RX f1'
RX f1'
RFU
OCBtype 2
Flexible WG
2+2 HSB DP Configuration
B.L W.G
M.P
S.P
2+2 HSB DPAM.AD.AM.AD.A
1.4/1.6dB 0.5dBN/A
N/A
N/A
N/A6/6.4dB 0.5dB
Item QtyRFU 4OCB Type 2 4Pole Mount 2Short 12Coupler Type 1 2Flex WG 1.2m 2DP Antenna 1XPIC cable 3m long 2IDC + Chassis 2IDM-155 4Protection Kit 2
FibeAir® 1500HP - Advanced High Power Radio System 17
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f2
RX f2
RX f2
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
50 ohm
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f2
RX f2
RX f2
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
50 ohm
Flexible WG
Flexible WG
2+2 HSB SP Configuration
Item QtyRFU 4OCB Type 1 2OCB Type 2 2Pole Mount 250ohm Termination 2Short 8U Bend 2Coupler Type 2 1Flex WG 1.2m 2SP Antenna 1IDC + Chassis 2IDM-155 4Protection Kit 2
B.L W.G
M.P
S.P
2+2 HSB SPAM.AD.AM.AD.A
2.1/2.3dB 0.5dBN/A
N/A
N/A
N/A7.5/7.9dB 1dB
FibeAir® 1500HP - Advanced High Power Radio System 18
Item QtyRFU 4OCB SD Type 2 4Pole Mount 2Short 450ohm Termination 4Coupler Type 1 4Flex WG 1.2m 2DP Antenna 2WG to N-Type Adap. Kit 2Coaxial Cable (m) 24N-Type connector 4XPIC cable 3m long 2IDC + Chassis 2IDM-155 4Protection Kit 2
FibeAir® 1500HP - Advanced High Power Radio System 19
2+2 SD SP Configuration
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f2
RX f2
RX f2
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
50 ohm
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f2
RX f2
RX f2
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
50 ohm
50 ohm
50 ohm
Flexible WG
Flexible WG
Flexible WG
Eliptical WG or Coax Cable
Item QtyRFU 4OCB SD Type 1 2OCB SD Type 2 2Pole Mount 250ohm Termination 4U Bend 4Coupler Type 2 2Flex WG 1.2m 3SP Antenna 2WG to N-Type Adap. Kit 1Coaxial Cable (m) 12N-Type connector 2IDC + Chassis 2IDM-155 4Protection Kit 2
B.L W.G
M.P
S.P
2+2 SD SPAM.AD.AM.AD.A
2.1/2.3dB 0.5dB
7.5/7.9dB 1dB
* Coax Cable 3.5/5dB
2.1/2.3dB 1.5/2.5dB*
7.5/7.9dB 2/3dB**
** Coax Cable 4/5.5dB
FibeAir® 1500HP - Advanced High Power Radio System 20
Item QtyRFU 4OCB Type 1 2OCB Type 2 2Pole Mount 250ohm Termination 2Short 8U Bend 2Flex WG 1.2m 2DP Antenna 1IDC + Chassis 2IDM-155 4Protection Kit 2
FibeAir® 1500HP - Advanced High Power Radio System 21
2+2 SD/FD DP Configuration
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f3
RX f3
RX f3
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f1
RX f1
RX f1
OCBtype 1
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f4'
RX f4'
RX f4'
OCBtype 2
RFU
TX Filter
RX Filter
RX Filter
TX
RX M
RX D
TX f2'
RX f2'
RX f2'
OCBtype 1
RFU
50
ohm
Eliptical WG or
Coax CableFlexible W
G
Flexible WG
50 ohm
50
ohm
50 ohm
B.L W.G
M.P
S.P
3+3 SD DPAM.AD.AM.AD.A
0.5dB0.5dB1.5/2.5dB*
N/AN/A
N/AN/A
0.5dB
* Coax Cable 3.5/5dB
Item QtyRFU 4OCB SD Type 1 2OCB SD Type 2 2Pole Mount 250ohm Termination 4Flex WG 1.2m 2U-Band 4DP Antenna 2WG to N-Type Adap. Kit 2Coaxial Cable (m) 24N-Type connector 4IDC + Chassis 2IDM-155 4Protection Kit 2
FibeAir® 1500HP - Advanced High Power Radio System 22
Upgrade Procedure
The following components need to be added when upgrading from 1+0 up to N+1:
OCBs
RFUs
IDMs
Flexible waveguides
When adding RF channels or carriers, RFUs and OCBs with specific filters need to be added as well.
The OCBs will be chained together using couplers (for the same frequency) or U-bends (for different frequencies), in accordance with the specific configuration.
Open ports on the OCBs will be terminated with 50 ohm terminations.
Detailed upgrade procedure documents are available for specific configurations.
Environmental Conditions Standard Compliance The system is fully compliant with the following standards:
Operational
RFU: ETS 300 019-1-4 class 4.1, with an operating temperature range of: -50°C to 55°C
Storage and Transportation
Storage: ETS 300 019-2-2 class 1.2, with a high temperature limit of: +85°C
Transportation: ETS 300 019-2-2 class 2.2
EMC
The system’s EMC and ESD requirements comply with the conditions specified in EN 300 385 [9] for class B.
Safety Conditions Standard Compliance The system complies with the UL 1950 and EN 60950 safety standards.
FibeAir® 1500HP - Advanced High Power Radio System 23
FibeAir 1500HP Components
1+0 Split-Mount Space Diversity Configuration
OCB U Bend Pole
Mount Kit
RFUs
OBN
Main Port
Diversity Port
OCB RFU
FibeAir® 1500HP - Advanced High Power Radio System 24
RFU - RF Unit
The RFU handles the main radio processing. It includes the following radio components: signal receiving, signal transmission, IF processing, and power supply.
There are two types of RFUs: one with a dual receiver, and one with a single receiver. The RFU with a dual receiver supports Space Diversity using IF combining, which combines two signals, main and diversity, and uses the combined signal to overcome multipath phenomenon (for Space Diversity configurations).
The RFU with a single receiver does not support Space Diversity using IF combining. This RFU will be used when Space Diversity with IF combining is not required.
Both RFUs support Space Diversity BBS (Base Band Switching) where the IF signal switching is performed in the IDU.
The two RFU types (with & without Space Diversity) have two different part numbers.
OCB - Outdoor Circulator Block. The OCB has the following main purposes:
1. Hosts the circulators and the attached filters.
2. Routes the RF signal in the correct direction, through the filters and circulators.
3. Allows RFU connection to the Main and Diversity antennas.
Two types of OCBs can be used:
Type1 OCB
Type2 OCB
The main difference between the two types is the circulator direction. Depending on the configuration, OCB Type 1 or Type2 is used together with waveguide shorts, waveguide loads, U Bends, or couplers.
Each OCB has four waveguide access points: two in the front, and two at the rear. The diversity access point is optional.
If the system is not configured for diversity, all the relevant access points on the OCB must be terminated using waveguide shorts.
The two OCB types (with & without space diversity) have different part numbers.
RF Filters RF Filters are used for specific frequency channels and Tx/Rx separation. The filters are attached to the OCB, and each RFU contains one Rx and one Tx filter. In a Space Diversity using IF combining configuration, each RFU contains two Rx filters (which combine the IF signals) and one Tx filter. The filters can be replaced without removing the OCB.
U Bend WG Kit The U Bend connects the secondary (OCB 2) RFU and the first RFU (OCB 1) in a 2+0 and N+1 Frequency Diversity configuration.
FibeAir® 1500HP - Advanced High Power Radio System 25
OBN - Outdoor Branching Network The OBN is a branching network for N radio systems. It provides the electrical and mechanical interface between the RFU and the antenna waveguides.
The OBN has several versions, depending on the system configuration and application.
The Branching Network contains N x OCBs (Outdoor Circulator Blocks), RF filters, and other waveguide components, connected in accordance with the system configuration (N+1, 2+0, etc.).
OBN components are integrated with the RFU to form a tightly sealed unit capable of withstanding harsh environmental conditions.
Coupler Kit The coupler kit is used for 1+1 Hot Standby configurations, with or without Space Diversity.
Pole Mount Kit The Pole Mount Kit is used to fasten the OCB and the RFU to the pole. The kit enables fast and easy installation.
FibeAir® 1500HP - Advanced High Power Radio System 26
Management
Ceragon provides state-of-the-art management based on SNMP. Our management applications are written in Java code and can control Ceragon units at both the element and network levels. The applications run on Windows 2000/XP/NT and UNIX systems.
CeraView® is Ceragon’s EMS (Element Management System) that enables the operator to perform element configuration, performance monitoring, remote diagnostics, alarm reports, and more. CeraView integrates with different NMS platforms to provide more comprehensive system management.
Example of a CeraView Main Window
PolyView™ is Ceragon’s end-to-end network management system that can monitor network element status, provide statistical and inventory reports, download software and configurations to elements, and more. PolyView includes CeraMap™, its powerful and friendly graphical interface. PolyView can also integrate with other NMS platforms to provide more comprehensive network management.
Example of a PolyView Alarm Log Window
FibeAir® 1500HP - Advanced High Power Radio System 27
FibeAir 1500HP Specifications RF Parameters
Frequency 6L GHz 6H GHz 7 GHz 8 GHz 11 GHz
Standards ETSI/FCC ETSI/FCC ETSI ETSI ETSI/FCC
Operating Frequency
Range (GHz)
5.925-6.425 6.425-7.1 7.1-7.9 7.725-8.5 10.7-11.7
RF Channel Spacing (MHz)
10/28/29.65/30 10/28/29.65/40 28/29.65 28/29.65/40 10/28/30/40
Tx Out (dBm)
STM-1 / OC-3
30 dBm @ 64 QAM 29 dBm @ 128 QAM
26 dBm @ 64 QAM 26 dBm @ 128 QAM
System Gain
(dBm) STM-1 /
OC-3
101 dBm @ 64 QAM 98 dBm @ 128 QAM
97 dBm @ 64 QAM 95 dBm @ 128 QAM
ATPC (dB)
23 dB @ 64 QAM 20 dB @ 128 QAM
Capacity 45 Mbps, 50/100/116/150/200 Mbps, (N+1) x 155 Mbps
Modulation Type QPSK, 16, 32, 64, 128, 256 QAM
System Configurations
Unprotected: 1+0 to N+0 Protected: 1+1; 2+2 Hot Standby, N+1 Frequency Diversity Co-channel operation with XPIC (CCDP) All configurations are available with Space Diversity
Wayside Channels NxE1/T1, Ethernet Bridge 10BaseT
User Channels V.11, or RS-232, or 10BaseT, or G.703 (optional)
Interface Modules STM-1 / OC-3/OC-3: Electrical - CMI/BNC, Optical - SM/SC, SM/MM DS3: Electrical Fast Ethernet: 100BaseT
Switching Hitless
Payload Types TDM: STM-1 / OC-3, DS3 ATM: ATM over SONET/SDH / SONET IP: Ethernet
Tx power values in the table are for split-mount installations. For all-indoor installations, the guaranteed Tx power is 3 dB higher.
All specifications are subject to change without prior notice.
All values are guaranteed.
FibeAir® 1500HP - Advanced High Power Radio System 28
Network Management
Type SNMP, in compliance with RFC 1213, RFC 1595 (SONET MIB)
Local or Remote NMS Station
CeraView and PolyView with advanced GUI for Windows 98/2000/XP/NT or UNIX, integrated with HP OpenView
NMS Interface Ethernet bridge 10Base-T, RS-232 (PPP, SLIP), built-in Ethernet hub
Local Configuration and Monitoring
Standard ASCII terminal, serial RS-232
In-Band Management
DCCr, DCCm, media-specific, proprietary
TMN Ceragon NMS functions are in accordance with ITU-T recommendations for TMN
Performance Monitoring
Integral with onboard memory per ITU-T G.828
Mechanical/Electrical
Transceiver (RFU) Dimensions
Height: 490 mm (19”)
Width: 144 mm (6”)
Depth: 280 mm (11”)
Weight: 7 kg (15 lbs) (excluding branching)
IDU-RFU Connection
Coaxial cable RG-223 (100 m/300 ft), Belden 9914/RG-8 (300 m/1000 ft) or equivalent, N-type connectors (male)
Maximum System Power Consumption
1+0: 105W
1+1: 150W
Indoor Temperature Range -5 C to +45 C
Outdoor Temperature Range -35 C to +55 C
Power Supply -40.5 to -72 VDC
FibeAir® 1500HP - Advanced High Power Radio System 29
Appendix: Frequency Channels
Note: For additional frequency plans not included in this appendix, contact your Ceragon representative.
6L GHz (5.85-6.45 GHz)
ITU-R F.383-7 [1-3]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 5955.00 1 6195.00 2 5995.00 2 6235.00 3 6035.00 3 6275.00 4 6075.00 4 6315.00 5 6115.00 5 6355.00
240
6 6155.00 6 6395.00
ITU-R F.383-7 [0] / FCC 101.147(i8)
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 5945.20 1 6197.24 2 5974.85 2 6226.89 3 6004.50 3 6256.54 4 6034.15 4 6286.19 5 6063.80 5 6315.84 6 6093.45 6 6345.49 7 6123.10 7 6375.14
252.04
8 6152.75 8 6404.79
FibeAir® 1500HP - Advanced High Power Radio System 30
FCC 101.147(i7)
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz
1 5935.32 1 6187.36 2 5945.2 2 6197.24 3 5955.08 3 6207.12 4 5964.97 4 6217.01 5 5974.85 5 6226.89 6 5984.73 6 6236.77 7 5994.62 7 6246.66 8 6004.5 8 6256.54 9 6014.38 9 6266.42
10 6024.27 10 6276.31 11 6034.15 11 6286.19 12 6044.03 12 6296.07 13 6053.92 13 6305.96 14 6063.8 14 6315.84 15 6073.68 15 6325.72 16 6083.57 16 6335.61 17 6093.45 17 6345.49 18 6103.33 18 6355.37 19 6113.22 19 6365.26 20 6123.1 20 6375.14 21 6132.98 21 6385.02 22 6142.87 22 6394.91 23 6152.75 23 6404.79
252.04
24 6162.63 24 6414.67
FibeAir® 1500HP - Advanced High Power Radio System 31
ITU-R F.384-7
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 5955.00 1 6215.00 2 6015.00 2 6275.00 3 6075.00 3 6335.00
260
4 6135.00 4 6395.00
ITU-R F.497-6 [0]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 5941.00 1 6207.00 2 5969.00 2 6235.00 3 5997.00 3 6263.00 4 6025.00 4 6291.00 5 6053.00 5 6319.00 6 6081.00 6 6347.00 7 6109.00 7 6375.00
266
8 6137.00 8 6403.00
6H GHz (6.45-7.1 GHz)
ITU-R F.384-7
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 6460.00 1 6800.00 2 6500.00 2 6840.00 3 6540.00 3 6880.00 4 6580.00 4 6920.00 5 6620.00 5 6960.00 6 6660.00 6 7000.00 7 6700.00 7 7040.00
340
8 6740.00 8 7080.00
FibeAir® 1500HP - Advanced High Power Radio System 32
FCC 101.147(k7)
T/R Separation
n (L)
Center Frequency
MHz n (H)
Center Frequency
MHz
1 6545 1 6715 2 6555 2 6725 170 3 6565 3 6735 4 6585 4 6745 5 6595 1 6755 6 6605 2 6765 7 6615 3 6775 8 6625 4 6785 9 6635 5 6795 10 6645 6 6805 11 6655 7 6815 12 6665 8 6825 13 6675 9 6835 14 6685 10 6845 15 6695 11 6855
160
16 6705 12 6865
7 GHz (7.1-7.9 GHz)
ITU-R 385-7 [1]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7442 1 7596 2 7470 2 7624 3 7498 3 7652 4 7526 4 7680
154A
5 7554 5 7708
FibeAir® 1500HP - Advanced High Power Radio System 33
ITU-R 385-7 [1]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7456 1 7610 2 7484 2 7638 3 7512 3 7666 4 7540 4 7694
154B
5 7568 5 7722
ITU-R 385-7 [1]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7442 1 7687 2 7470 2 7715 3 7498 3 7743 4 7526 4 7771 5 7554 5 7799 6 7582 6 7827 7 7610 7 7855
245
8 7638 8 7883
FibeAir® 1500HP - Advanced High Power Radio System 34
ITU-R 385-7 [0]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7138.5 1 7299.5 2 7166.5 2 7327.5 3 7194.5 3 7355.5 4 7222.5 4 7383.5 5 7250.5 5 7411.5
11 7145.5 11 7306.5 12 7173.5 12 7334.5 13 7201.5 13 7362.5 14 7229.5 14 7390.5 21 7152.5 21 7313.5 22 7180.5 22 7341.5 23 7208.5 23 7369.5 24 7236.5 24 7397.5 31 7159.5 31 7320.5 32 7187.5 32 7348.5 33 7215.5 33 7376.5
161A
34 7243.5 34 7404.5
ITU-R 385-7 [0]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7263.5 1 7424.5 2 7291.5 2 7452.5 3 7319.5 3 7480.5 4 7347.5 4 7508.5 5 7375.5 5 7536.5
11 7270.5 11 7431.5 12 7298.5 12 7459.5 13 7326.5 13 7487.5 14 7354.5 14 7515.5 21 7277.5 21 7438.5 22 7305.5 22 7466.5 23 7333.5 23 7494.5 24 7361.5 24 7522.5 31 7284.5 31 7445.5 32 7312.5 32 7473.5 33 7340.5 33 7501.5
161B
34 7368.5 34 7529.5
FibeAir® 1500HP - Advanced High Power Radio System 35
ITU-R 385-7 [0]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7438.5 1 7599.5 2 7466.5 2 7627.5 3 7494.5 3 7655.5 4 7522.5 4 7683.5 5 7550.5 5 7711.5
11 7445.5 11 7606.5 12 7473.5 12 7634.5 13 7501.5 13 7662.5 14 7529.5 14 7690.5 21 7452.5 21 7613.5 22 7480.5 22 7641.5 23 7508.5 23 7669.5 24 7536.5 24 7697.5 31 7459.5 31 7620.5 32 7487.5 32 7648.5 33 7515.5 33 7676.5
161C
34 7543.5 34 7704.5
ITU-R 385-7 [0]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7563.5 1 7724.5 2 7591.5 2 7752.5 3 7619.5 3 7780.5 4 7647.5 4 7808.5 5 7675.5 5 7836.5
11 7570.5 11 7731.5 12 7598.5 12 7759.5 13 7626.5 13 7787.5 14 7654.5 14 7815.5 21 7577.5 21 7738.5 22 7605.5 22 7766.5 23 7633.5 23 7794.5 24 7661.5 24 7822.5 31 7584.5 31 7745.5 32 7612.5 32 7773.5 33 7640.5 33 7801.5
161D
34 7668.5 34 7829.5
FibeAir® 1500HP - Advanced High Power Radio System 36
ITU-R 385-7 [0]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz
1 7435 1 7596 2 7463 2 7624 3 7491 3 7652 4 7519 4 7680
161I
5 7547 5 7708
ITU-R 385-7 [0]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz
1 7428 1 7589 2 7456 2 7617 3 7484 3 7645 4 7512 4 7673
161J
5 7540 5 7701
ITU-R 385-7 [0]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz
1 7498 1 7659 2 7526 2 7687 161K 3 7554 3 7715
FibeAir® 1500HP - Advanced High Power Radio System 37
ITU-R 385-7 [3]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7457 1 7625 2 7485 2 7653 3 7513 3 7681 4 7541 4 7709
168B
5 7569 5 7737
ITU-R 385-7 [1]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7428 1 7610 2 7456 2 7638 3 7484 3 7666 4 7512 4 7694
182
5 7540 5 7722
ITU-R 385-7 [3]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7121 1 7317 2 7149 2 7345 3 7177 3 7373 4 7205 4 7401
196
5 7233 5 7429
FibeAir® 1500HP - Advanced High Power Radio System 38
ITU-R 385-7 [4]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7442 1 7687 2 7470 2 7715 3 7498 3 7743 4 7526 4 7771 5 7554 5 7799 6 7582 6 7827 7 7610 7 7855
245
8 7638 8 7883
8 GHz (7.8-8.5 GHz)
ITU-R 386-6 [4]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7926 1 8192 2 7954 2 8220 3 7982 3 8248 4 8010 4 8276 5 8038 5 8304 6 8066 6 8332 7 8094 7 8360
266
8 8122 8 8388
FibeAir® 1500HP - Advanced High Power Radio System 39
ITU-R 386-6 [1]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7747.70 1 8059.02 2 7777.35 2 8088.67 3 7807.00 3 8118.32 4 7836.65 4 8147.97 5 7866.30 5 8177.62 6 7895.95 6 8207.27 7 7925.60 7 8236.92
311.32A
8 7955.25 8 8266.57
ITU-R 386-6 [1]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 7732.875 1 8044.195 2 7762.525 2 8073.845 3 7792.175 3 8103.495 4 7821.825 4 8133.145 5 7851.475 5 8162.795 6 7881.125 6 8192.445 7 7910.775 7 8222.095
311.32B
8 7940.425 8 8251.745
ITU-R 386-6 [3]
T/R Separation
n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 8293 1 8412 2 8307 2 8426 3 8321 3 8440 4 8335 4 8454 5 8349 5 8468
119
6 8363 6 8482
FibeAir® 1500HP - Advanced High Power Radio System 40
11 GHz (10.4-11.7 GHz)
ITU-R 387-8 [0]
T/R Separation
Block n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 10715 1 11245 2 10755 2 11285 3 10795 3 11325 4 10835 4 11365 5 10875 5 11405 6 10915 6 11445 7 10955 7 11485 8 10995 8 11525 9 11035 9 11565 10 11075 10 11605 11 11115 11 11645
530A
12 11155 12 11685
ITU-R 387-8 [0,2] FCC 101.147 [7]
T/R Separation
Block n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 10735 1 11225 2 10775 2 11265 3 10815 3 11305 4 10855 4 11345 5 10895 5 11385 6 10935 6 11425 7 10975 7 11465 8 11015 8 11505 9 11055 9 11545 10 11095 10 11585 11 11135 11 11625
490A
12 11175 12 11665
FibeAir® 1500HP - Advanced High Power Radio System 41
CEPT/12-6 E
T/R Separation
Block n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 10715 1 11205 2 10755 2 11245 3 10795 3 11285 4 10835 4 11325 5 10875 5 11365 6 10915 6 11405 7 10955 7 11445 8 10995 8 11485 9 11035 9 11525 10 11075 10 11565
490B
11 11115 11 11605
ITU-R 387-8 [6]
T/R Separation
Block n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 1 10730 1 11250 2 10790 2 11310 3 10850 3 11370 4 10910 4 11430 5 10970 5 11490 6 11030 6 11550 7 11090 7 11610
520A
8 11150 8 11670
FibeAir® 1500HP - Advanced High Power Radio System 42
ITU-R 387-8 [6]
T/R Separation
Block n (L)
Center Frequency
MHz
n (H)
Center Frequency
MHz 500 1 10715 1 11215
2 10755 2 11245 3 10795 3 11285 4 10835 4 11325 5 10875 5 11365 6 10915 6 11405 7 10955 7 11445 8 10995 8 11485 9 11035 9 11525 10 11075 10 11565 11 11115 11 11605
490C