CELL-tainer® Single use Bioreactor
November 2013
CellD20bis, rue du Chapitre F-30150 ROQUEMAURETel : +33 (0)4 66 82 82 60Fax : +33 (0)4 66 90 21 10Email : [email protected] www.celld.com
CELL-tainer®
A new single-use bioreactor with two-dimensional movement that offers superior mass transfer rates and short mixing times with low shear for high density cell culture and microbial fermentation
2
Features
MASS-transfer & mixing
Two dimensional rocking improves mixing and oxygen transfer
Proper and accurate temperature control
Heating by convection (incubator)
Direct cooling (heat exchanger under the bag)
Short mixing times => no gradients
EASY handling & real single use
Bags flexible in volume
Robust design (stackable)
In-line measurements non-invasive,
fully disposable (pH, DO,), bottom mounted,
others (glucose/lactate)
Scaleable
Same process performance at different scales
Complete system Incubator chamberIntegrated process controls with HMI touchscreen21 CFR part 11 compliantPLC controller for rpm, pH, DO, Temp3 x Gas flow metersPressure gauges2 x Addition pumpsHeavy duty motorRemovable bag tray
Features
Specifications
CELL-tainer® single-use bag
Microbial bag
Benefits
Pre-sterilized and disposable
Reduce handling
Plug and play operation
Quick change over
Expansion in a single bag
=
Minimize contamination risk
Reduce variability
Save time and labor
Cycle time reduction
Cost effective
7
2-dimensional movement
8
The kla-value determined with the dynamic gassing in/out method including the off-gas analysis.
At the 20 L CELL-tainer, optimal filling volumes are above 8L, rocking speeds above 25 rpm.
At the 200 L CELL-tainer, the optimal filling volume ranges between 90 and 130L. At rocking speeds between 15 and 25 rpm, highest kla-values of 400 h-1 are obtained.
0
100
200
300
400
500
600
15
20
25
30
35
68
1012
14
kLa
[h-1
]
rpm
Liquid volume [L]
0
100
200
300
400
500
600
10
15
20
25
30
8090
100110
120130
140150
kla-value at different rocking speeds
12 L
120 L
Cultivation of E. coli (Fed-batch):
Final cell dry mass concentration of 45 gL-1 (OD=140) obtained in 35 h.
(Junne et al, ChemieIngenieurTechnik Vol. 85 2013)
Cultivation results
11
Batch and Fed-batch E.coli
20L CELL-tainer®
CELL-tainer® scale up
CONFIDENTIAL
200L CELL-tainer®
CELL-tainer® 200L single-use bag
Mammalian: 5L – 200L working volume
Microbial: 5L – 120L working volume
CONFIDENTIAL
Service Support
CONFIDENTIAL 16
1 Year Manufacturer’s Warranty-Covers mechanical and electronic parts not subject to wear and tear (excluding labor and travel)
Service support-24 hour response with phone/email support to troubleshoot and diagnose problem-If issue is not resolved, an engineer will schedule on-site visit for servicing
Anton Tromper - [email protected]
Ruben Engelhart - [email protected]
Lexan Lhu – [email protected]
Spare parts-Stocked at Charter Medical and available to ship FedEx next day
Optional add-on services / products-Maintenance contract - -Site Acceptance Test (at customer site) - one day for CT20 and 2 days for CT200, excluding travel-Operational training (at customer site) - one day for CT20 and 2 days for CT200, excluding travel-CELL-tainer DACS software for one CELL-tainer including 1 Modbus license -CELL-tainer DACS software for one CELL-tainer including 1 Modbus license -Modbus license for connecting additional CELL-tainer (up to 8) -HMI license for connecting additional CELL-tainer (up to 8)
THANK YOUFor More Information: www.CharterMedical.com