Ceiling Tgl Dcetail Set Interior
Transcript of Ceiling Tgl Dcetail Set Interior
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 1/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section: page: TIT
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
GLADIUSTM
GLADIUS INTERIOR DETAILS
PRODUCT CATEGORY: PLANK & TILE - GLADIUSDRAWING FILE: TGL_DETAILS
C E I L I N G P A N E L S
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 2/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: TO
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N SW O O D C E I L I N G S
GLADIUS
TABLE OF CONTENTS
PRODUCT CATEGORY: PLANK & TILE - GLADIUSDRAWING FILE: TGL_PERF_TABLE OF CONTENTS
C E I L I N G P A N E L S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 3/33
All rights reserved. This drawing
is the property of Hunter
Douglas and may not be copied
or multiplied neither wholly nor
partly. It may not be submitted
for perusal to third parties
either.5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0214
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850 www.hunterdouglascontract.com
R
M E T A L C E I L I N G S
The Gladius metal ceiling panels from Hunter Douglas feature "
standard 1516" grid systems. The self-centering, self-leveling
confirmed by an audible "click."
1516" T-Grid system installed in accordance with ASTM C636 and lo
BEND DOWN TABS PANEL INSTALLATION
BACK OF PANEL
STANDARD TERMINATION - Box Mold FLOATING TERMINATION - Cut panels.Safety clips not shown for clarity.
Safety clips not
shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 4/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL - 24" x 24" nominal
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_24x24
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 1
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
SECTION ASCALE: 1:1
SECTION BSCALE: 1:1
BACK OF PANEL
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 5/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL - 24" x 18" nominal
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_24x18
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 2
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
SECTION ASCALE: 1:1
SECTION BSCALE: 1:1
BACK OF PANEL
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 6/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL - 24" x 12" nominal
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_24x12
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 3
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
SECTION ASCALE: 1:1
SECTION BSCALE: 1:1
BACK OF PANEL
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 7/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL - 24" x 6" nominal
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_24x6
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 4
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
SECTION ASCALE: 1:1
SECTION BSCALE: 1:1
BACK OF PANEL
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 8/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL INSTALLATION
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_INSTALLATION
A C O U S T I C S O L U T I O N S
R
M E T A L C E I L I N G S
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 5
PANEL AND GRID (back of system)
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 9/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL REMOVAL
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_REMOVAL
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 6
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
PANEL AND GRID (back of system)
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 10/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANELS ISOMETRIC
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_ISOMETRIC
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 7
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
GLADIUS PANEL ISOMETRIC
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 11/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
2' x 2' LAY-IN LIGHT WITH GLADIUS
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_LAY-IN LIGHT
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 8
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
2' x 2' LAY-IN LIGHTSCALE: 1 12" = 1'-0"
2' x 2' LAY-IN LIGHTSCALE: 1 1
2" = 1'-0"
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 12/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL WITH DOWN LIGHT
PRODUCT CATEGORY: PLANK & TILE
DRAWING FILE: TGL_DOWN LIGHT (1)
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 9
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
PANEL WITH ROUND CUT-OUT
SECTION ASCALE: 3" = 1'-0"
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 13/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL WITH DOWN LIGHT
PRODUCT CATEGORY: PLANK & TILE
DRAWING FILE: TGL_DOWN LIGHT (2)
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 10
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
RECESSED DOWN LIGHT
ROUND CUT-OUTSCALE: 1 1
2" = 1'-0"
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 14/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS PANEL WITH SPRINKLER
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_SPRINKLER
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 11
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
PANEL WITH ROUND CUT-OUT
SECTION ASCALE: 3" = 1'-0"
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 15/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILBOX MOLD TRIM
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_BOX MOLD
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 12
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at box moldSCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at box moldSCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 16/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILWALL ANGLE
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_ANGLE
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 13
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at wall angleSCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at wall angleSCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 17/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FULL PANEL PERIMETER DETAILWALL ANGLE
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_FULL_ANGLE
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 14
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - full panel at wall angleSCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - full panel at wall angleSCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 18/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILSTEP TRIM
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_STEP
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 15
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at step trimSCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at step trimSCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 19/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FULL PANEL PERIMETER DETAILSTEP TRIM
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_FULL_STEP
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 16
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - full panel at step trimSCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - full panel at step trimSCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 20/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FULL PANEL PERIMETER DETAILGL02
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_FULL_GL02
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 17
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - full panel at GL02SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - full panel at GL02SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 21/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FULL PANEL PERIMETER DETAILGL04
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_FULL_GL04
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 18
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - full panel at GL04SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - full panel at GL04SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 22/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FULL PANEL PERIMETER DETAILGL06
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_FULL_GL06
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 19
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - full panel at GL06SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - full panel at GL06SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 23/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILLX02
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_LX02
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 20
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at LX02SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at LX02SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 24/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILLX03
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_LX03
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 21
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at LX03SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at LX03SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 25/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILLX04
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_LX04
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 22
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at LX04SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at LX04SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 26/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILLX06
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_LX06
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 23
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at LX06SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at LX06SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 27/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILLX08
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_LX08
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 24
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at LX08SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at LX08SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 28/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILLX10
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_LX10
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 25
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at LX10SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at LX10SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 29/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
GLADIUS FIELD CUT PERIMETER DETAILLX12
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_TRIM_CUT_LX12
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 26
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
TYPICAL PERIMETER SECTION - cut panel at LX12SCALE: 3" = 1'-0"
TYPICAL PERIMETER SECTION - cut panel at LX12SCALE: 3" = 1'-0"
Safety clips not shown for clarity.
Safety clips not shown for clarity.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 30/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
SEISMIC LAY-OUT FOR GLADIUSD, E, F
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_SEISMIC_LAY-OUT_DEF
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 27
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
SEISMIC LAY-OUT FOR GLADIUS - D, E, FSCALE: 3
4" = 1'-0"
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 31/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
SEISMIC PERIMETER SECTIONWALL ANGLE
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_SEISMIC_TRIM_ANGLE
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 28
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
SEISMIC PERIMETER SECTION - cut panel with wall angleSCALE: 3" = 1'-0"
Safety clips not shown for clarity.
INTERNATIONAL BUILDING CODE (IBC) SEISMIC CATEGORY D, E, AND F
ALTERNATIVE PERIMETER TREATMENT USING CODE APPROVED PERIMETER CLIP.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 32/33
All rights reserved. This drawing is the property of Hunter Douglas and may be
used only in conjunction with construction projects utilizing Hunter Douglas
products. This detail may not apply to all conditions or construction situations.
For non-typical conditions, consult Hunter Douglas.
SEISMIC PERIMETER SECTIONSTEP TRIM
PRODUCT CATEGORY: PLANK & TILEDRAWING FILE: TGL_SEISMIC_TRIM_STEP
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
1 Hunter Douglas Circle
Thornton, CO 80241
800-727-8953
fax: 720-872-7850
www.hunterdouglascontract.com
drawn: Cdate: 03-section:
page: 29
R
M E T A L C E I L I N G S A C O U S T I C S O L U T I O N S
SEISMIC PERIMETER SECTION - cut panel with step trimSCALE: 3" = 1'-0"
Safety clips not shown for clarity.
INTERNATIONAL BUILDING CODE (IBC) SEISMIC CATEGORY D, E, AND F
ALTERNATIVE PERIMETER TREATMENT USING CODE APPROVED PERIMETER CLIP.
W O O D C E I L I N G S
TM
8/10/2019 Ceiling Tgl Dcetail Set Interior
http://slidepdf.com/reader/full/ceiling-tgl-dcetail-set-interior 33/33
5015 Oakbrook Parkway, Suite 100
Norcross, GA 30093
800-366-4327 / 770-806-9557
fax: 770-806-0217
GLADIUSC E I L I N G P A N E L S