CEC301a_30566_Dixie Patriot

35
Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 1 of 35 © DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS. RECORD OF APPROVED SHIP SAFETY EQUIPMENT Certificate No: 30566 DNV GL Id No: 30566 Date of issue: (yyyy-mm-dd) To meet the provisions of the International Convention for the safety of Life at Sea, 1974 and Amendments thereto. This form should be kept on board and be available for inspection by a nominated surveyor or regognised organisation at all times. Particulars of Ship Name of Ship: “DIXIE PATRIOT” Port of Registry: SINGAPORE Gross Tonnage: 2509 Flag: SINGAPORE IMO Number: 8765694 Yard: Semco LLC Yard No: 1010 Date on which keel was laid: 2002 Class Notation: DNV Type of Ship 1 : Other Cargo Ship Range of service / service area restriction: UNLIMITED VOYAGE Distinctive Number or Letters: PV6920 Official Number: 397852 Name of known sister ship(s): N/A Previous names: N/A Previous flags: MARSHALL ISLANDS Freeboard length 1.13 m Length over all 51.63 m B.P. length m Max breadth 34.53 m Max draught 3.96 Total number of persons for which LSA are provided Passenger vessels and special purpose ship: Passenger vessels: Max number of crew Max number of passengers / special personnel Number of compartment (1, 2 compartment vessel) N/A N/A N/A Main engine manufacturer CATERPILLAR Total number 2 Model type 3512B Power output each 1118 kW Auxiliaries engine 3412 Output 450 kW Emergency generator 3306B Output 2092kW 1 Insert the standard IMO ship type.

Transcript of CEC301a_30566_Dixie Patriot

Page 1: CEC301a_30566_Dixie Patriot

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 1 of 35

© DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

RECORD OF APPROVED SHIP SAFETY

EQUIPMENT

Certificate No: 30566

DNV GL Id No:

30566 Date of issue:

(yyyy-mm-dd)

To meet the provisions of the International Convention for the safety of Life at Sea, 1974 and

Amendments thereto. This form should be kept on board and be available for inspection by a nominated surveyor or

regognised organisation at all times.

Particulars of Ship

Name of Ship: “DIXIE PATRIOT”

Port of Registry: SINGAPORE

Gross Tonnage: 2509

Flag: SINGAPORE

IMO Number: 8765694

Yard: Semco LLC

Yard No: 1010

Date on which keel was laid: 2002

Class Notation: DNV

Type of Ship1 : Other Cargo Ship

Range of service / service area restriction: UNLIMITED VOYAGE

Distinctive Number or Letters: PV6920

Official Number: 397852

Name of known sister ship(s): N/A

Previous names: N/A

Previous flags: MARSHALL ISLANDS

Freeboard length

1.13 m

Length over all

51.63 m

B.P. length

m

Max breadth

34.53 m

Max draught

3.96

Total number of persons for which

LSA are provided

Passenger vessels and special purpose ship:

Passenger vessels:

Max number of crew

Max number of passengers / special personnel

Number of compartment (1, 2 compartment vessel)

N/A N/A N/A

Main engine manufacturer

CATERPILLAR

Total number

2

Model type

3512B

Power output each

1118 kW

Auxiliaries engine

3412

Output

450 kW

Emergency generator

3306B

Output

2092kW

1 Insert the s tandard IMO ship type.

Page 2: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 2 of 35

Type of main/aux boilers

N/A

Number Main/Aux boiler

N/A

Exemptions / Additional information:

N/A.

2 Safety of Navigation

2.1 Shipborne Navigation Equipment (V/19 and V/20)2 I f more than one piece of equipment is ins talled, this to be indicated by e.g. 2 off

Item Manufacturer/Model

2.1.1.13 Standard magnetic compass Yokogana Denshikiki Co. LTD

Means of communication between standard magnetic compass and normal navigation

control position

Yokogana Denshiki Co. LTD

Steering magnetic compass Ritchie

2.1.1.23 Spare magnetic compass N/A

2.1.1.33 Gyro compass ANSCHUTZ (STD22) DigitalGyro

2nd Gyro compass N/A

2.1.1.43 Gyro compass heading repeater N/A

2.1.1.53 Gyro compass bearing repeater N/A

2.1.1.63 Heading or track control system N/A

2.1.1.73 Pelorus or compass bearing device N/A

2.1.1.8 Means of correcting heading and bearings N/A

2.1.1.93 Transmitting heading device (THD) N/A

2.1.2.1 Nautical charts (paper charts) Provided: Yes No

Electronic chart display and information system (ECDIS)

N/A

2.1.2.2 Back-up arrangements for ECDIS N/A

2.1.2.3 Printed nautical publications Provided: Yes No

Electronic nautical publications Provided: Yes No

2.1.2.4 Back-up arrangements for electronic nautical publications

Provided: Yes No

2 Manufacturer and Type Approved. See EU-MED.001a.

3 A lternative means of meeting this requirement are permitted under regulation V/19. In case of other means, they shall be specified in 2 .5 of this record

Page 3: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 3 of 35

Item Manufacturer/Model

2.1.3.13 Receiver for a global navigation satellite system (GNSS)

JRC/NCR-330

Terrestrial radionavigation system N/A

2.1.3.23 9 GHz radar JRC/JMA 7710-6/NCD-3901-2

2.1.3.33 Additional 3 GHz radar N/A

Additional 9 GHz radar N/A

2.1.3.43 Automatic radar plotting aid (ARPA) N/A

2.1.3.53 Automatic tracking aid (ATA) N/A

2.1.3.63 Second automatic tracking aid (ATA) N/A

2.1.3.73 Electronic plotting aid (EPA) N/A

2.1.4.1 Automatic identification system (AIS) JRC JHS-182/NCM-779

2.1.4.2 Long Range Identification and Tracking (LRIT)

N/A

2.1.5.1 Voyage data recorder (VDR) N/A

2.1.5.2 Simplified voyage data recorder (S-VDR) N/A

2.1.6.13 Speed and distance measuring device

(through the water) N/A

2.1.6.23 Speed and distance measuring device (in the forward and athwartships directions over the

ground)

2.1.73 Echo sounding device Garmin/GPSMAP 526

2.1.8.13 Rudder angle indicator N/A

2.1.8.1.13 Propeller revolution indicator N/A

2.1.8.1.23 Propeller pitch and mode indicator N/A

2.1.8.1.33 Thruster indicator N/A

2.1.8.23 Rate-of-turn indicator N/A

2.1.93 Sound reception system N/A

2.1.103 Telephone to emergency steering position N/A

2.1.113 Daylight signalling lamp

(Source of power )

N/A

2.1.123 Radar reflector N/A

2.1.13.1 International Code of Signals Provided: Yes No

2.1.13.2 Copy of Volume III of IAMSAR Manual Provided: Yes No

2.1.14 Night vision equipment (HSLC requirement) Provided: Yes No

2.1.15 Bridge navigational watch alarm system (BNWAS)

N/A

2.1.16 N/A N/A

2.1.17 N/A N/A

2.2 Sound Signal Appliances and Shapes (COLREG 1972, as amended)

Item Provided/- Location

2.2.1 Forecastle bell N/A Bridge

2.2.2 Gong N/A Bridge

Page 4: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 4 of 35

2.2.3 Ships whistle

Whistle approved for the following length

m

2.2.4 Black ball shape Bridge

2.2.5 Black diamond shape Bridge

2.2.6 Black cylindrical shape Bridge

2.3 Navigation Lights (COLREG 1972, as amended)

2.3.1 Horizontal distance

Foremast light abaft top of stem N/A m Between foremast and mainmast lights N/A m

2.3.2 Vertical height above waterline in lightest ballast condition

Foremast light N/A m Mainmast light N/A m

2.3.3 Vertical height above uppermost continuous deck

Foremast light m Mainmast light m Sidelights m

2.3.4 Navigation Lights Power type electric

Miles range Duplex type (two tier)

Source of electrical power (SOLAS II-1/41, 42, 43)

Yes No Yes No

2.3.4.1 Fore masthead light (225°, white)

nm main emergency

2.3.4.2 Main masthead light (225°, white)

nm main emergency

2.3.4.3 Port side light

(112,5°, red)

nm main emergency

2.3.4.4 Starboard side light (112,5°,

green)

nm main emergency

2.3.4.5 Stern light

(135°, white)

nm main emergency

2.3.4.6 Towing light

(135°, yellow)

nm main emergency

2.3.4.7 Forward anchor light (360°, white)

nm main emergency

2.3.4.8 Aft anchor light

(360°, white)

nm main emergency

2.3.4.9 Upper NUC light

(360°, red)

nm main emergency

2.3.4.10 Lower NUC light

(360°, red)

nm main emergency

2.3.4.11 RAM lights nm main emergency

2.3.4.12 Upper and lower RAM lights combined with NUC lights:

2.3.4.13 Rotational Yellow

Light (HSLC)

nm main emergency

Page 5: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 5 of 35

2.4 Pilot transfer arrangement on either side of the ship (V/23)

2.4.1 Pilot ladder

Manufacturer

N/A

Material

Length

m

2.4.2 Accommodation ladder, if used in conjunction with pilot ladder4

Manufacturer

N/A

Material

Length

m

Falls

Number

Diameter

mm

Material

Length

m

2.4.3 Bulwark ladder/hinged rail

Manufacturer

N/A

Material

2.5 Means of embarkation on and disembarkation from ships (II-1/3-9)

2.5.1 Gangway

Manufacturer

N/A

Material

Length

m

SWL

2.5.2 Accommodation ladder, if not included in 2.4.2

Manufacturer

N/A

Material

Length

m

Falls

Number

Diameter

mm

Material

Length

m

SWL

Minimum operational angle: Maximum operational angle:

(Not more than 55 degrees)

2.6 Additional information

Item No. Comment

3 Life–Saving appliances

3.1 Rockets and signals (III/6, 18) Provided /-

3.1.1 Line throwing appliances with 4 rockets and lines 3 pc

3.1.2 12 rocket parachute flares 14 pc

3.2 Communications (III/6)

3.2.1 Portable two-way VHF radiotelephone apparatus 4 pcs (GMDSS)

3.2.2.1 Search and rescue locating devices N/A

3.2.2.2 One search and rescue and rescue locating device in free fall life boat (may be one of the required 2)

N/A

4 The accommodation ladder shall be sited leading aft, with lower end firmly rested against ship’s s ide

Page 6: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 6 of 35

3.2.2.3 Satellite EPIRB (capable of being carried into survival craft) 1 pc

3.2.3 Emergency means for two-way communications between emergency control stations, muster and embarkation stations and strategic

positions on board

3.2.4 Means of communication between embarkation station and platform (for ships fitted with MES only)

N/A

3.2.5 Public address system N/A

3.2.5.1 Location of control(s)

3.2.6 General emergency alarm system Bridge

3.2.6.1 Means of abandon ship warning Bridge

Location of control(s) Bridge

Location of control(s) Bridge

3.3 Survival craft, muster, launching and embarkation arrangement, launching station

No. Number of persons

Location

Deck Position

(frame, ship side)

3.3.1.1 Muster station 1 75 Main deck PORT

3.3.1.2 Muster station 2 75 Main deck SB

3.3.1.3 List of additional Muster stations

attached

Yes

No

3.3.2.1 Embarkation station

SB 100 Main deck SB

3.3.2.2 Embarkation station

PORT 100 Main deck Port

3.3.2.3 Embarkation station

N/A N/A N/A N/A

3.3.2.4 Embarkation station

N/A N/A N/A N/A

No. Length Location

Deck Position

(frame, ship side)

3.3.3.1 Embarkation ladder

N/A N/Am N/A N/A

3.3.3.2 Embarkation ladder

N/A N/Am N/A N/A

3.3.3.3 Embarkation ladder

N/A N/Am N/A N/A

3.3.3.4 Embarkation ladder

N/A N/Am N/A N/A

3.3.3.5 Alternative means (descent unit)

N/A N/Am N/A N/A

N/A N/Am N/A N/A

Page 7: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 7 of 35

3.3.4 Provided / -

At least two lifelines fitted to davit spans for open and partially enclosed lifeboats

LOCATION OF SURVIVAL CRAFT AND RESCUE BOATS

RB M LR

M LR

Indicate positions of lifeboat/liferafts group, MES and rescue boats. Indicate "M" for motor boats; "MP" for mechanically propelled boats;"R" for rowing boats; ""F" for free fall boats; "LR" for liferafts, “MES” for

MES and "RB" for rescue boats.

Assign number to lifeboats.

3.4 Lifeboats

No(s).

2

No(s).

1

No(s).

No(s).

No(s).

No(s).

3.4.1 Lifeboats

(III/16, 21, 31)

3.4.1.1 Position (Starboard Side SB, Port Side PS,

Stern S)

Stb side Port side

3.4.1.2 Capacity (Number of persons)

75 75

3.4.1.3 Dimensions

Length: 8.50 m 8.50 m m m m m

Breadth: 3.30 m 3.30 m m m m m

Depth: 1,25(3.30) m

1,25(3.30) m

m m m m

3.4.1.4 Weight (fully loaded

and equipped)5

10887,5

kg

10887,5

kg

kg kg kg kg

3.4.1.5 Material Glass fibre

reinforced plastic

Glass fibre

reinforced plastic

3.4.1.6 Manufacturer Jiangyin Jiangyin

3.4.1.7 Type/Trade name NPT58F /tottaly

NPT58F /tottaly

5 Note that weight of a person is 75 kg on ships with keel laid before 2010-07-01 and 82.5 kg on or after 2010-07-01 for lifeboats and

rescue boats on cargo ships

Page 8: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 8 of 35

enclosed

lifeboat

enclosed

lifeboat

3.4.1.8 Serial Number 852/343 852342

3.4.1.9 Approved by SOLAS SOLAS

3.4.1.10 Approval number N/A N/A

3.4.1.11 Free-fall

3.4.1.12 Totally enclosed

3.4.1.13 Partially enclosed

3.4.1.14 Open6

3.4.1.15 Motor

3.4.1.16 Mechanically propelled

3.4.1.17 Rowing6

3.4.1.18 Self-righting

3.4.1.19 Fire-Protected7

3.4.1.20 With self-contained air supply system7

3.4.1.21 Approved and used as rescue boat

3.4.1.22 Used as passenger

tender boat

3.4.2 Release mechanism

for lifeboats

NPT3.36

/HK3.36(SWL:

3.36 Ton)

NPT3.36

/HK3.36(SWL:

3.36 Ton)

3.4.2.1 Manufacturer Jiangyin Jiangyin

3.4.2.2 Release hook mechanism type

NPT3.36/HK3.36

(SWL:

3.36 Ton)

NPT3.36/HK3.36

(SWL:

3.36 Ton)

3.4.2.3 Approved by Shanghai

ESD/ABS

Shanghai

ESD/ABS

3.4.2.4 Approval number 07-SQ24699

0-1-PDA

07-SQ24699

0-1-PDA

3.4.2.5 On load release Hook compliant with LSA

Code as amended

N/A N/A

3.4.3 Lifeboat Equipment (III and LSA Code)

Each lifeboat is equipped as follows (indicate number or Yes, No , N.A. as appropriate)

Item Lifeboat No.

6 Keel laid before 1st July 1986 7 O n Tankers only

Page 9: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 9 of 35

2 1

3.4.3.1 Number of rowing oars (including spare oars), except freefall lifeboat

N/A N/A

3.4.3.2 Crutches or equivalent for each oar

N/A N/A

3.4.3.3 Automatic valves (with cap or plug)

M/A N/A

3.4.3.4 Rudder (attached with tiller) N/A N/A

3.4.3.5 Lifeline becketed around the outside of the boat

N/A N/A

3.4.3.6 Bilge pump(s) manually operated N/A N/A

3.4.3.7 Lockers for small items of equipment

N/A N/A

3.4.3.8 Painters, 1 secured to stem, 1 secured forward, with release

device able to operate under tension

N/A N/A

3.4.3.9 Painters (2) of at least 15 m in length stowed near the bow (for

free-fall lifeboats only)

N/A N/A

3.4.3.10 Boat hooks (2) N/A N/A

3.4.3.11 Buoyant bailer with lanyards N/A N/A

3.4.3.12 Buckets (2) with lanyards N/A N/A

3.4.3.13 Survival manual N/A N/A

3.4.3.14 Sea anchor (1) with shock-

resistant hawser and tripping line (if fitted)

N/A N/A

3.4.3.15 Hatchets (axes, one at each end of the boat)

N/A N/A

3.4.3.16 Rustproof dipper with lanyard N/A N/A

3.4.3.17 Rustproof graduated drinking vessel (1)

N/A N/A

3.4.3.18.1 Fresh water (3 l per person in watertight receptacles), or

N/A N/A

3.4.3.18.2 Water desalting apparatus and 2 l

fresh water per person, or

N/A N/A

3.4.3.18.3 Manually powered reserve-

osmosis desalinator and 1 l fresh water per pers.

N/A N/A

3.4.3.19 Means for collecting and storing rainwater

N/A N/A

3.4.3.20 Food ration of approved type in airtight receptacles stowed in watertight containers totalling not

less than 10,000 kJ per person,

N/A N/A

3.4.3.21 Waterproof electric torch (1) with one spare set of batteries and one spare bulb in waterproof container

N/A N/A

Page 10: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 10 of 35

Item Lifeboat No.

2 1

3.4.3.22 Daylight signalling mirror (1) N/A N/A

3.4.3.23 Whistle (1) or equivalent sound signal

N/A N/A

3.4.3.24 Fishing tackle (1 set) N/A N/A

3.4.3.25 Buoyant rescue quoits (2) attached to

not less than 30 m of buoyant

lifeline

N/A N/A

3.4.3.26 Jack knife (1) attached to boat with lanyard

N/A N/A

3.4.3.27 Tin-openers (3) N/A N/A

3.4.3.28 Life-saving signals (table) on a waterproof card or in waterproof

container

N/A N/A

3.4.3.29 First-aid outfit in a waterproof case (1)

N/A N/A

3.4.3.30 Anti-seasickness medicine

sufficient for at least 48 hours for each person

N/A N/A

3.4.3.31 Seasickness bag (1) for each person

N/A N/A

3.4.3.32 Short ladder or the means of climbing into upright boat from

the water

N/A N/A

3.4.3.33 Skates or fenders (and skids if required) to facilitate launching

against adverse list

N/A N/A

3.4.3.34 Hand holds on underside of hull (only for non-self-righting boats)

N/A N/A

3.4.3.35 Retro-reflective material N/A N/A

3.4.3.36 Safety belt fitted at each seating position (totally enclosed lifeboats

only)

N/A N/A

3.4.3.37 Manually controlled internal and external lamps able to be

operated for 12 hours

N/A N/A

3.4.3.38 Rocket parachute flares (4) N/A N/A

3.4.3.39 Hand flares (6) N/A N/A

3.4.3.40 Buoyant smoke signals (2) N/A N/A

3.4.3.41 Searchlight able to operate

continuously for at least 3 hours (1) (not required for oar or

mechanically propelled lifeboat)

N/A N/A

3.4.3.42 Thermal protective aids for 10 %

or 2 whichever is greater

N/A N/A

3.4.3.43.1 Radar reflector (1) or N/A N/A

3.4.3.43.2 Search and rescue locating device N/A N/A

Page 11: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 11 of 35

Item Lifeboat No.

2 1

stowed in lifeboat

3.4.3.44 Compass in binnacle, efficiently luminized or illuminated

N/A N/A

3.4.4 Additional requirements for open lifeboats6

3.4.4.1 Grablines gunwale to gunwale

(2 minimum)

N/A N/A

3.4.4.2 Mast with galvanised wire stays and orange sail (not required for

motor or mechanically propelled boats)

N/A N/A

3.4.4.3 Cover, highly visible for protecting occupants with stanchions

N/A N/A

3.4.4.4 A lamp with sufficient oil for 12 hours

N/A N/A

3.4.4.5 Matches in watertight container

(2)

N/A N/A

3.4.4.6 Storm oil (4.5 litres) N/A N/A

3.4.4.7 Storm oil container for attaching

to sea anchor

N/A N/A

3.4.4.8 Bowsing tackles to hold boat

against ship’s side

N/A N/A

3.4.4.9 Number of rowing thwarts N/A N/A

3.4.4.10 Steering oar N/A N/A

3.4.4.11 Plugs (2 for each plug hole with chain attachment), or

N/A N/A

3.4.4.12 Automatic valves in lieu N/A N/A

3.4.5 Additional requirements for partially enclosed lifeboats

3.4.5.1 Adjustable closing arrangements from inside and outside the boat

N/A N/A

3.4.5.2 Means for collecting rainwater N/A N/A

3.4.6 Motor lifeboats

3.4.6.1 Engine type, diesel BUKH

DV29 RME

BUKH

DV29 RME

3.4.6.2 Engine power (kW) 21.3

kW

21.3

kW

3.4.6.3 Fuel capacity – litres (sufficient for 24 hours running with 6 knots)

180 ltr

180 ltr

3.4.6.4 Means provided for recharging all engine starting, radio and

searchlight batteries

N/A N/A

3.4.6.5 Means provided for recharging lifeboat batteries from the ships

N/A N/A

Page 12: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 12 of 35

Item Lifeboat No.

2 1

power supply or by means of a solar battery charger

3.4.6.6 Water-resistant instructions for starting and operating the engine

provided and placed near the engine starting controls

N/A N/A

3.4.6.7 Sufficient tools for minor adjustments to the engine and its

accessories

N/A N/A

3.4.6.8 Portable fire-extinguishing

equipment of an approved type (suitable for oil fires)

N/A N/A

3.4.6.9 If also rescue boat towing force of the rescue boat as indicated in the

type approval certificate (sufficient to tow the largest fully

loaded liferaft on board at a speed of two knots) (kN)

N/A N/A

3.4.6.10 If also rescue boat buoyant line not less than 50 m in length and

sufficient strength to tow a liferaft (1)

N/A N/A

3.4.7 Additional requirements for free-fall lifeboats (IACS UI SC 248)

3.4.7.1 Free-fall certification height

Note: The free-fall certification

height is the greatest launching height for which the free-fall

lifeboat is approved.

N/Am N/Am

m

m

m

m

3.4.7.2 Ready to launch position height

Note: The “ready to launch

position” height is to be measured

from the still water surface to the lowest point on the lifeboat with

the ship in its lightest seagoing condition. This height must be

equal or less than the free-fall

certification height.

N/Am N/Am m

m

m

m

3.5 Rescue Boats (excluding lifeboats approved as rescue boats and already included

in 3.4 above)

3.5.1 Rescue Boats (III/21, 26, 31) Rescue boat No. 1

Rescue boat No. 2

3.5.1.1 Position

Ship side PS SB PS SB

Deck main deck

Frame area

3.5.1.2 Capacity (Number of persons)5 6

3.5.1.3 Dimensions Length (m) 4,5

Breadth (m) 1,77

Page 13: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 13 of 35

Depth (m) 0,70

3.5.1.4 Manufacturer Fassmer

3.5.1.5 Type/Trade name RR 4,5ID

3.5.1.6 Material GRP

3.5.1.7 Serial number N/A

3.5.1.8 Approved by IMO/SOLAS

3.5.1.9 Approval number N/A

3.5.1.10 Rigid rescue boat

3.5.1.11 Inflated rescue boat

3.5.1.12 Fast rescue boat

3.5.1.13 Engine manufacturer N/A

3.5.1.14 Engine type Diesel

3.5.1.15 Engine power (kW) 27,8 kW

3.5.1.16 Towing force of the rescue boat as indicated in the type approval certificate (sufficient to tow the largest fully loaded liferaft on board at a speed of two knots)

kN

N/A

3.5.2 Rescue boat equipment (III and LSA Code) Each rescue boat equipped as follows:

3.5.2.1 Oars or paddles (sufficient to make headway) N/A

3.5.2.2 Thole pins, crutches or equivalent for each oar N/A

3.5.2.3 Thole pins or crutches attached to the boat by

lanyards or chains

N/A

3.5.2.4 Buoyant bailer (1)

3.5.2.5 Binnacle containing an efficient luminous compass

3.5.2.6 Sea anchor with tripping line not less than 10 m in length (1)

3.5.2.7 Painter of sufficient length and strength at fore end (1)

N/A

3.5.2.8 Buoyant line not less than 50 m in length and

sufficient strength to tow a liferaft (1)

N/A

3.5.2.9 Waterproof electric torch suitable for Morse signalling (1)

N/A

3.5.2.10 Spare set of batteries and spare bulb in waterproof container (1)

N/A

3.5.2.11 Whistle or equivalent (1) N/A

3.5.2.12 First-aid outfit in waterproof case (1) N/A

3.5.2.13 Buoyant rescue quoits attached to buoyant line of not

less than 30 m in length (2)

N/A

3.5.2.14 Portable fire-extinguishing equipment of an approved type (suitable for oil fires)

N/A

3.5.2.15 Effective means of bailing or fitted with automatic self-bailing arrangements

N/A

3.5.2.16 Searchlight able to operate continuously for at least 3 hours

N/A

3.5.2.17 Radar reflector N/A

Page 14: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 14 of 35

3.5.2.18 Thermal protective aids for 10 % or 2 whichever is greater

N/A

3.5.3 Additional requirements for inflated rescue boats

3.5.3.1 Buoyant safety knife (1) N/A

3.5.3.2 Sponges (2) N/A

3.5.3.3 Efficient manually operated bellows or pump N/A

3.5.3.4 Repair kit in suitable container for repairing punctures N/A

3.5.3.5 Safety boat-hook N/A

3.5.4 Additional requirements for rigid rescue boats

3.5.4.1 Boat-hook (1) N/A

3.5.4.2 Bucket (1) N/A

3.5.4.3 Knife or hatchet (1) N/A

3.6 Liferafts

3.6.1 Liferafts (III/21, 31; LSA Code) excluding any liferaft stowed forward or aft for compliance with III/31.1.4 (Ro-Ro Passenger ships only: at least every fourth liferaft should be

provided with a search and rescue locating device)

3.6.1.1 Stowage position of liferafts or liferaft groups

Item No(s). 1

No(s).2 No(s).3 No(s).4 No(s).1 No(s).2 No(s).3 No(s).4

Stowed at deck

main deck

main deck

main deck

main deck

main deck

main deck

main deck

main deck

PS or SB SB SB SB SB Port Port Port Port

Frame area maine

deck

main

deck

main

deck

main

deck

main

deck

main

deck

main

deck

main

deck

Max. permitted

stowage

height above water line

36m 36m 36m 36m 36m 36m 36m 36m

State actual stowage

height

N/Am N/Am N/Am N/Am N/Am N/Am N/Am N/Am

3.6.1.2 Manufacturer SurvitecZodia

cDL

SurvitecZodia

cDL

SurvitecZodia

cDL

SurvitecZodia

cDL

SurvitecZodia

cDL

SurvitecZodia

cDL

SurvitecZodia

cDL

SurvitecZodiacD

L

Type Solas A Solas A Solas A Solas A Solas A Solas A Solas A Solas A

Number of pers.

25 25 25 25 25 25 25 25

A or B pack N/A N/A

N/A N/A N/A N/A N/A N/A

Transferable from side to

side

Auto. Self-right

Canopied reversible

Page 15: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 15 of 35

Davit

launched

Search and

rescue locating

device

Served by MES

3.6.1.3 Float free arrangement for liferafts

Type: hydrostatic release. If not, please specify

Manufacturer Survite

cZodiacDL

Survite

cZodiacDL

Survite

cZodiacDL

Survite

cZodiacDL

Survite

cZodiacDL

Survite

cZodiacDL

Survite

cZodiacDL

Survitec

ZodiacDL

Type N/A N/A N/A N/A N/A N/A N/A N/A

3.6.2 Additional liferaft(s) stowed forward or aft (III/31.1.4) (hydrostatic release not required)

3.6.2.1 Stowage position of liferafts

Item No. N/A No.N/A

Stowed at deck N/A N/A

PS, Centre or SB N/A N/A

Frame area N/A N/A

Max. permitted stowage height above water line N/A m N/A m

State actual stowage height N/Am N/Am

3.6.2.2 Manufacturer N/A N/A

Type N/A N/A

Number of pers. N/A N/A

Transferable from side to side

Auto. Self-right

Canopied reversible

A or B pack

3.7 Marine Evacuation System [MES] (III/21, III/26 and LSA Code)

3.7.1 Stowage position

Item MES No(s). N/A

MES No(s). N/A

MES No(s). N/A

MES No(s).N/A

Ship side PS SB PS SB PS SB PS SB

Deck N/A N/A N/A N/A

Frame area N/A N/A N/A N/A

Maximum permitted stowage height above

waterline

N/Am N/Am N/Am N/Am

Indicate actual stowage height

N/Am N/Am N/Am N/Am

3.7.2 Description/ Type N/A N/A N/A N/A

Manufacturer N/A N/A N/A N/A

Number of persons N/A N/A N/A N/A

Time N/A N/A N/A N/A

Page 16: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 16 of 35

3.8 Additional information

Item No. Comment

N/A N/A

N/A N/A

N/A N/A

3.9 Means of Rescue “MOR” (III/26.4, MSC/Circ. 810)

3.9.1 Means of rescue acc. to III/26.4.3

3.9.2 Device providing a suitable floating platform

Description Hoisting Arrangement

3.9.2.1 Inflatable device N/A N/A N/A

3.9.2.2 Rigid device N/A N/A

3.10 Launching appliances for survival craft and rescue boat (III/16, 21 and 31; LSA

Code)

3.10.1 Lifeboat launching appliances

3.10.1.1

Lifeboat – Davits

Boat

No(s).

Manufacturer Type Max. SWL Min starting

01 Port Jiangyin Neptune

marine

NPT 138 DP 140 kNkg kg

02 SB Jiangyin Neptune marine

PT 138 DP 140 kNkg kg

kg kg

kg kg

kg kg

kg kg

3.10.1.2 Lifeboat – Winches

Boat No(s).

Manufacturer Type Max. SWL Remote controlled

Yes/No

01 Port Jiangyin Neptune NPT DW 1389 N/A kg N/A

02 SB Jiangyin Neptune NPT DW 1389 N/A kg N/A

kg

kg

kg

kg

3.10.1.3 Lifeboat - Falls

Boat No(s).

Length (m)

Diameter (mm)

Breaking Load (kg)

Corrosion Resistant

Rotation Resistant

Core Fiber/

Steel

No. of purchase

1, 2, or

38

Construction (number of

designating

number of wires and

strands)

8 Indicate s ingle (1), double (2) or treble (3) indicates number of wires attached to movable pulley for lifting the lifeboat

Page 17: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 17 of 35

N/A N/A N/A N/A N/A N/A N/A N/A N/A

3.10.1.4 Lifeboat – Hanging off pendants

Boat No(s).

Provided /- Max. SWL

N/A N/A N/A kg

kg

3.10.1.5 Means of launching lifeboats N/A

3.10.1.6 Maximum number of persons on board the fully equipped lifeboat which the launching appliance is capable to recover N/A

3.10.2 Liferaft launching arrangements (III/16; LSA Code)

3.10.2.1

Liferaft – Davits / Cranes

Liferaft station (s)

Manufacturer Type Max. SWL Lowering speed empty liferaft

SB site NED -DECK Marine SCM 21-4,0 L 23 kN kg N/A m/s

PORT site NED -DECK Marine SCM 21-4,0 L 23 kN kg N/A m/s

kg m/s

kg m/s

kg m/s

kg m/s

3.10.2.2 Liferaft – Winches

Liferaft station (s)

Manufacturer Type Max. SWL

SB site NED -DECK Marine 04-03 M 23 kN kg

PORT site NED -DECK Marine 04-03 M 23 kN kg

kg

kg

kg

kg

3.10.2.3 Liferaft – Hooks

Liferaft station (s)

Manufacturer Type

SB site NED -DECK Marine Hook Car 35

PORT site NED -DECK Marine Hook Car 35

Page 18: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 18 of 35

3.10.2.4 Liferaft – Falls

Liferaft station (s)

Length (m)

Diameter (mm)

Breaking Load (kg)

Corrosion Resistant

Rotation Resistant

Core

Fibre/

Steel

Construction (number of

designating number of

wires and

strands)

N/A N/A N/A N/A N/A N/A N/A N/A

3.10.3 Launching and recovery arrangement for rescue boat (III/17; LSA Code)

3.10.3.1 Rescue boat – Davit / Crane

Boat No(s).

Manufacturer Type Max. SWL

SB Ned Deck Marine PRHE 30 30kN kg

kg

3.10.3.2 Rescue boat – Winches

Boat No(s).

Manufacturer Type Max. SWL

SB Ned Deck Marine N/A 30kN kg

kg

3.10.3.3.1 Rescue boat – Hooks

Boat No(s).

Manufacturer Type

SB Ned Deck Marine CAR 35

3.10.3.3.2 Foul weather recovery strops (if provided)

Boat No(s).

Manufacturer SWL

N/A N/A N/A

3.10.3.4 Rescue boat – Falls

Boat No(s).

Length (m)

Diameter (mm)

Breaking Load (kg)

Corrosion Resistant

Rotation Resistant

Core

Fibre/

Steel

No. of purchase

1, 2, or 38

Construction (number of

designating number of

wires and strands)

N/A N/A N/A N/A N/A N/A N/A N/A N/A

Page 19: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 19 of 35

3.10.4 Launching and recovery arrangement for means of rescue (III/17; LSA Code)

3.10.4.1 Means of rescue - Falls

No(s). Length

(m)

Diameter

(mm)

Breaking

Load (kg)

Corrosion

Resistant

Rotation

Resistant

Core

Fibre/

Steel

No. of

purchase 1, 2, or

38

Construction

(number of designating

number of wires and

strands)

N/A N/A N/A N/A N/A N/A N/A N/A N/A

3.11 Other life-saving appliances (III/7, 22, 26 and 32; LSA Code)

Item Number Manufacturer/Type Location

3.11.1 Life jackets for adults with whistle and light

110 N/A Acommodations cabin, main deck,

muster stations, bell

deck

3.11.1.1 Additional life jackets for persons on watch and for use at remotely

located survival craft stations

N/A

3.11.1.2.1 Additional life jackets (for 5% of the total number of passengers on board passenger ships only)

N/A

3.11.1.2.2 Additional lifejackets for passengers in staterooms located

remotely from direct routes between public spaces and

muster stations (passenger ships

constructed on or after 1998-07-01)9

N/A

3.11.1.2.3 Number of adult lifejackets designed with suitable

accessories to fit persons weighing up to 140 kg and with a

chest girth up to 1750mm

N/A

3.11.1.3.1 Life jackets for children (equal to

at least 10% of the number of passengers)

N/A

3.11.1.3.2 Life jackets for infants (passenger ships only):

For voyages of less than 24 h:

equal to at least 2.5 % of the number of passengers,

For voyages of 24 h or greater: for all infants

N/A

3.11.22 Immersion suits N/A

3.11.2.1 Immersion suits (one for every person on cargo ship).

N/A

3.11.2.2 Immersion suits for persons on watch and for use at remotely

located work stations on cargo

N/A

9 For Ro-Ro passenger ships: a sufficient number of lifejackets is s tored at the muster s tation

Page 20: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 20 of 35

ship.

3.11.2.3 Number of immersion suits

complying with the requirements for lifejackets

N/A

3.11.2.4 Anti-exposure suits (for every person assigned to the crew the

rescue boat or assigned to the MES party)

N/A

3.11.310 Thermal protective aids (for Passenger ship only)

N/A

3.11.4 Lifebuoys11

11 3 level, main deck, 4 level,

3.11.4.1 With light and smoke signal,

capable of quick release from the bridge (at least 2)

N/A

3.11.4.2 With self-igniting light only N/A

3.11.4.3 With buoyant lifelines (1 on each side)

N/A

3.11.4.4 Without attachments N/A

3.11.4.5 In way of pilot access if not on main deck

N/A

3.12 Additional information

Item No. Comment

N/A N/A

4 Fire Fighting Equipment (Ch. II-2)

4.1 Fire-fighter outfit (FSS Code Ch. 3. Reg 2.1, II-2/10.10)

4.1.1 Personal equipment (please indicate number of provided equipment)

ID no.

Location Protective suit (s)

Boots Gloves Rigid helmet

Life

line

Axe Safety lamp

Safety belt harness

Others

1 sailor

deck on officer

line 3

2

3

4

5

6

10 Not including the ones required as part of the lifeboat, rescue boat or liferaft equipment 11 O nly lifebuoys on open decks are to be recorded, not less than 50 % with light

Page 21: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 21 of 35

7

8

Personal equipment Manufacturer Type

4.1.1.1 Protective suits

4.1.1.2 Boots

4.1.1.3 Gloves

4.1.1.4 Rigid helmet

4.1.1.5 Lifeline

4.1.1.6 Axe

4.1.1.7 Safety lamp

4.1.1.8 Safety belt harness

4.1.1.9 Two-way portable radios

(2 per fire party)

4.1.1.10 Others

4.1.2 Self-contained breathingapparatus

ID no.

Location Type/

Manufacturer

Low pressure

alarm

fitted?

Capacity (litres)

(at least 1200 l)

Spare capacity

(at least 2400 l)

1 SB muster station Breathing

Apparatus UK(sabre)

yes 3 liters 200 bar

2

3

4

5

6

7

8

9

10

4.1.2.1 Air compressor for filling of air bottles Yes No

4.1.2.2 Spare cylinders for training purposes Number N/A Yes No

4.2 Fire Extinguishers (II-2/10.3, 10.5, 18.5, 19.3.7, 20.6.2; FSS Code, Chapter 4)

4.2.1 Item Location Number Extinguishing medium

(i.e. CO2, Foam, etc)

Capacity No. of spare charges

Portable Accommodation sickbay DCP 6kg N/A

extinguishers spaces OFFICE SSBU(2

rooms)

CO2 6kg N/A

rooms 30 DCP 1,33kg N/A

alley level 6 DCP 1,33kg N/A

Page 22: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 22 of 35

galley inside 2 DCP 4,5 kg N/A

Service spaces GYM level CO2 6kg N/A

paint locker 2 DCP 6,8kg N/A

laundry room 1 DCP 4,5kg N/A

funnels SB/Port 2 DCP 4,5kg N/A

fire locker 2 DCP/CO2 4,5kg N/A

Control stations Lifeboad,

STB/Port;FRC

DCP 1,13kg N/A

Bridge 4 DCP 1,13KG N/A

ER stairways stbd/port

2 DCP 4,5 KG N/A

ECR stbd/port/main

3 DCP/CO2 4,5;22kg

leasure rooms 3 C02 6kg N/A

Machinery spaces

E`CY Gen.

area

1 CO2 5kg N/A

Engine store room

1 DCP 4,5kg N/A

BA compressor bridge wing Stbd

1 DCP 1,13kg N/A

Cargo spaces and

cargo pump rooms

STBD/Port cranes

2 4,5kg N/A

red container 9 FOAM/DCP/C

02

9kg;

9kg;30LBS

N/A

Helicopter landing

area

Helideck level 9 DCP 4,5; 9;22,7;

1,13kg

N/A

Item Location Number Type Capacity No. of spare charges

4.2.2 Portable foam

applicator units

Machinery spaces

4.2.3 Non-Portable Machinery spaces

(wheeled)

Page 23: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 23 of 35

extinguishers

4.2.4 Water fog

applicator

Machinery spaces

4.3 Fire pumps, fire main, hydrants, hoses etc. (II-2/10.2)

4.3.1 Fire pumps and fire main

Fire Pumps Capacity (m³/h) Prime mover Location Remote controlled from

Bridge Central fire control

station

4.3.1.1 Main fire pump

500 Bell deck

4.3.1.2 Main fire pump

4.3.1.3 Main fire pump

4.3.1.4 Emergency fire pump*

500 Bell deck

4.3.1.5 *Source of power/Location

4.3.1.6 Fire main diameter (nominal bore (NB)) mm

4.3.1.7 Location of machinery space fire main riser isolating valve(s)

4.3.1.8 Specify means for maintaining a permanent pressure in the fire

main pump (pump and tank)

4.3.1.9 Main pressure in fire main with two pumps and two jets of water N/mm2

4.3.1.10 Relief valves

4.3.2 Hydrants

Location Number Diameter (NB)

(mm)

Type of coupling

4.3.2.1 Machinery spaces 6

4.3.2.2 Weather deck 2

4.3.2.3 Accommodation and service spaces

9

4.3.2.4 Ro-Ro cargo spaces

4.3.2.5 Others 21 N/A N/A

4.3.3 Hoses and nozzles

Location Number Hose diameter

(mm)

Hose length

(m)

Hose material Spray / jet nozzle with

shut-off

4.3.3.1 Machinery spaces

4.3.3.2 Weather deck 8

4.3.3.3 Accommodation and service spaces

8 pcs

4.3.3.4 Ro-Ro cargo spaces

4.3.3.5 Others Helideck

Page 24: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 24 of 35

(5pcs)

4.4 International shore connection (II-2/ 10.2.1.7; FSS Code, Chapter 2)

4.4.1 No. Location(s)

N/A N/A

4.5 Additional information

Item No. Comment

5 Fire extinguishing systems (II-2) in Engine room, Cargo spaces, Pump room, accommodation, service spaces etc

5.1. Arrangement

5.1.1 Spaces protected

CO2 Halon Fixed foam

Fixed pressure water spray

or mist

(drenching)

Automatic sprinkler or

equivalent

Dry powder

Other gas system

Others12

Main deck Stbd side

C02room main deck

Galley

Bell deck

5.1.2 If no extinguishing system is fitted for cargo holds, both the conditions in 5.1.2.1 to 5.1.2.3 apply

Applicable N.A

5.1.2.1 Hatch covers are of steel and effective means are provided for closing all ventilators and other openings leading

5.1.2.2 The ship is constructed and solely intended for carrying ore, coal, grain, unseasoned timber and non combustible cargoes or cargoes which are considered to constitute a low fire risk

5.1.2.3 Ventilator fans can be stopped and doorways, ventilators and all other openings to cargo spaces can be closed from outside

the space concerned

5.2 CO2 system(s) (II-2/10.5, 10.6.3, 10.7, 10.9, 20.6.1; FSS Code, chapter 5)

Spaces protected

Bottles Location of remote

control

Type of audible alarm

(Horn, Siren,

Others)

Operation instructions

posted –

location

No. Capacity

each (kg)

Location

Main deck Stbd side

CO2 2btls

x6,8kgs

maine deck

Stbd

others add padlock

when

12 In case of others please specify

Page 25: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 25 of 35

side received

Galley N/A others

main deck N/A CO2 room main

deck

5.3 Systems using gases other than CO2 (II-2/10.5, 10.6.3, 10.7, 10.9, 20.6.1; FSS

Code, chapter 5.2.5)

Type of gas: N/A System Approved by: N/A Approval No.: N/A

Spaces protected

Bottles Location of remote control

Type of audible alarm (Horn, Siren,

Others)

Operation instructions posted –

location

No. Capacity each (kg)

Location

N/A N/A N/A N/A N/A N/A N/A

5.4 Halon system (II-2/10.4.1.3) (Pre 1992-07-01)

5.4.1 Spaces protected

Stowage containers Location of remote

control

Type of audible

alarm

Release of the

system13

Operation instructions

posted – location

No. Capacity each (kg)

Location

N/A N/A N/A N/A N/A N/A N/A N/A

5.4.2 Type of propellant gas

5.5 Fixed foam fire extinguishing system(s) (II-2/10.5, 10.8, 10.9, 20.6.1; FSS Code,

chapter 6 and 14)

Details Spaces protected

Engine/Boiler room

Cargo area/Cargo

tank

Cargo pump room

13 O nly local systems are permitted to have automatic release! A – automatically M – manually

Page 26: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 26 of 35

5.5.1 Foam concentrate Type14 N/A N/A N/A

Manufacturer N/A N/A N/A

Min. quantity (litres) N/A 20 ltr N/A

Concentration ratio N/A N/A N/A

Expansion ratio N/A N.A. N/A

5.5.2 Foam fire extinguishing

system pump

Type N/A N/A N/A

Location N/A N/A N/A

Capacity (m³/h) N/A N/A N/A

5.5.3 Location of foam tank N/A Bell deck N/A

5.5.4 Location of controls N/A 3rd level N/A

5.5.5 Manufacturers service instruction manual

provided

5.5.6 Means of supply Monitors on tank deck Manufacturer Capacity

litres/mi

n

Type Number

Applicators/foam generators

Machinery spaces

Tank deck

Manufacturer

Type

Number

Number of hydrants

Number of hoses

5.5.7 Additional info:

5.6 Fixed pressure water-spraying or water mist system(s) (II-2/10.5, 10.6.3, 10.9;

FSS Code, chapter 7)

5.6.1 Spaces

protected

Pumps Nozzles Location of

control Location Capacity (m³/h)

Type Manufacturer

accommo

dation

Main deck

5.6.2 Type approval certificate number

5.7 Drencher (deluge) system (II-2/19.3.1.3, 19.3.9, 20.6.1)

Spaces protected Pumps Location of controls (section valves) Location Capacity m3 /h

14 Engine room: Syntetic, FP or P. Cargo Deck: Regular, Alcohol Resistant, Syntetic or P rotein Based

Page 27: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 27 of 35

5.8 Automatic sprinkler or equivalent, fire detection and fire alarm system(s) (II-2/10.6.1

and 10.6.2; FSS Code, chapter 8)

5.8.1 Spaces protected

Automatic independent power pump

Sources of power

Sprinkler plan posted

Location of stop (section) valves

Location Capacity (m³/h)

5.8.2 Sources of emergency power for electrically driven pumps

5.8.3 Location of emergency source of power

5.8.4 Fresh water tank capacity m³

5.8.5 Sprinkler head type Manufacturer Number of spaces

5.8.6 Type approval certificate number

5.8.7 Location of cross-connection valve to fire main

5.9 Dry powder system for gas carriers (ICG Code / GC Code: Art. 11.4) and chemical

tankers (IBC Code / BCH Code: paragraphs 11.3.2 / 3.14.2; 11.3.13 and Ch. 17/6)

Details Spaces protected

Cargo area Bow or stern cargo

handling

System Manufacturer N/A N/A

Type N/A N/A

No of self-contained units N/A N/A

Means of supply:

Hoses

Number N/A N/A

Manufacturer N/A N/A

Type N/A N/A

Length N/A N/A

Capacity N/A N/A

Means of supply:

Monitors

Number N/A N/A

Manufacturer N/A N/A

Type N/A N/A

Capacity N/A N/A

5.10 Galley range exhaust duct protective system (II-2/9.7.5)

5.10.1 Type of system Locations of controls for release and closing

of fire dampers

Locations of exhaust fan shut-

off controls

Number of bottles

Total capacity

(kg)

Page 28: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 28 of 35

N/A N/A N/A N/A N/A

5.11 Fixed local application fire extinguishing system(s) (II-2/10.5.6)

5.11.1 Manufacturer and type of the system(s) N/A

5.11.2 Type approval certificate number N/A

5.11.3 Release of the system Automatically Manually

5.11.4 Pump unit: emergency /fire pumps 2 units

Location N/A Capacity 500GPM/500GPM

m³/h

5.11.5 Location of remote controls 4th level

5.11.6 Type designation of the spraying nozzles N/A

5.11.7 Protected areas ; accommodation area

5.11.7.1 Engine top of internal combustion machinery used for ship’s main

propulsion

5.11.7.2 Engine top of internal combustion machinery used for the ship’s power generation

5.11.7.3 Oil burners of boilers and thermal oil heaters

5.11.7.4 Oil burners of incinerators

5.11.7.5 Oil burners of inert gas generators

5.11.7.6 Purifiers of heated fuel oil

5.11.7.7 Other areas, details

5.12

Fire extinguishing system for deep-fat cooking equipment (II-2/10.6.4)

Manufacturer Type approval

certificate number

Release of the system

Manually Automatically

N/A N/A

N/A N/A

5.13 Sand receptacles and shovels or equivalent arrangement (II-2/10.5.1.2.3)

5.13.1 In each firing space, there is a sand receptacles with

Shovel An approved fire extinguisher

5.14 Spaces containing flammable liquids (paint lockers) II-2/10.6.3

System Manufacturer Type Approved by Approval No.

Carbon

dioxide

N/A N/A N/A N/A

Dry powder N/A N/A N/A N/A

Water spraying or sprinkler

N/A N/A N/A N/A

Portable CO2 N/A N/A N/A N/A

Other N/A N/A N/A N/A

5.15 Additional information

Item No. Comment

N/A N/A

Page 29: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 29 of 35

6 Fire protection, fire detection and alarm system(s) (II-2/7.5, 7.7, 8.5, 9.2, 10.6; FSS Code, chapter 9 and 10)

6.1 Method of fire protection and alarm systems in accommodation and service spaces

on cargo ships (II-2/7.5.5, 7.7, 9.2.3.2.2, 10.6.2)

Method IC Smoke detection and manually operated call points in all corridors, stairways and escape routes within

accommodation spaces

Method IIC Automatic sprinkler, fire detection and fire alarm system

of an approved type in accommodation spaces, galleys and other service spaces

Method IIIC Fixed fire detection and fire alarm system of an approved type in accommodation and service spaces

6.2 Fire protection and alarm systems on passenger ships in accommodation and

service spaces and control stations (II-2/ 7.5.3, 10.6.1)

Passenger ships carrying not more than 36 passengers

6.2.1 Fixed fire detection and fire alarm system in accommodation and service spaces, and control stations provided, and smoke detection system in

corridors, stairways and escape routes within accommodation spaces provided

6.2.2 Automatic sprinkler, fire detection and fire alarm system in accommodation and service spaces and control stations provided, and

smoke detection system in corridors, stairways and escape routes within accommodation spaces provided

6.2.3 Location of control panel bridge

6.2.4 Location of indicating units bridge

6.3 Passenger ships carrying more than 36 passengers

6.3.1 Automatic sprinkler, fire detection and fire alarm system as well as

smoke detection system in all accommodation and service spaces and control stations including corridors, stairways and escape routes provided

6.3.2 Smoke extraction system of an approved type (II-2 / 8.5; applicable to atriums only)

6.3.3 Low-location lighting

6.3.4 Location of control panel bridge

6.3.5 Location of indicating units bridge

6.4 Gas detection-portable instruments and fixed systems (II-2/4.5.7)

6.4.1 Portable

Gas Manufacturer Type Approved by Approval no. No. of spares

N/A N/A N/A N/A N/A N/A

6.4.2 Fixed system Spaces fitted

Hydrocarbon gas

Other

Other

Page 30: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 30 of 35

Spaces monitored

N/A

6.5 Additional information

Item No. Comment

N/A N/A

7 Emergency control/Special arrangements in machinery and accommodation spaces (II-2/5.2, 7.9.3, 8.3, 9.5)

7.1 Means for stopping ventilation fans and pumps and other auxiliary machinery

outside space concerned

Means Location

7.1.1 Ventilation fans

Machinery spaces full completed accordance amount of

personal on board

machinery

Accommodation full completed accordance amount of personal on board

7.1.2 Boiler fans N/A N/A

7.1.3 Purifiers N/A N/A

7.1.4 Oil fuel transfer pumps N/A N/A

7.1.5 Oil fuel and lubricating oil tank valves

N/A N/A

7.1.6 Lube Oil Service Pumps N/A N/A

7.1.7 Thermal Oil Circulating Pumps N/A N/A

7.1.8 Other N/A N/A

7.1.9 Capable of being closed from outside the space concerned

Ventilators Funnel annular spaces

Skylights Doorways Tunnel door

7.2 Additional information

Item No. Comment

N/A N/A

N/A N/A

N/A N/A

8 Personnel protection (Chapter II-2)

8.1 Emergency escape breathing devices (EEBDs)

(II-2/13.3.4, 13.4.3; FSS Code, chapter 3, para. 2.2)

Number of EEBDs:

In machinery spaces

Accommodation spaces

Spare devices Training devices

Total on board

N/A full completed accordance amount of

personal on

board

N/A N/A N/A

8.2 Additional information

Page 31: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 31 of 35

Item No. Comment

N/A N/A

9 Special arrangements

9.1 Inert gas system (II-2/4.5.5; FSS Code, chapter 15) For tankers constructed on or

after 2016-01-01 required for tankers with deadweight 8000 and above. Ref

SOLAS 2014Am II-2/4.5.5.1

9.1.1 Type of system (15)N/A Approved by N/A Instruction manual provided N/A

9.1.1.1 General requirements for all inert gas systems

9.1.1.1.1 The system is capable of producing a gas delivery rate of at least 125%

of the maximum rate of discharge capacity of cargo pumps N/A

9.1.1.1.2 Gas scrubber locator N/A

9.1.1.1.3 Number and locator of gas blowers N/A

9.1.1.1.4 Location of gas regulation valve N/A

9.1.1.1.5 Location of deck waterseal N/A

9.1.1.1.6 Type and location of other non-return devices N/A

9.1.1.1.7 Each cargo tank may be isolated by a stop valve / a blank spade (16) N/A

9.1.1.1.8 Blank flanges are provided to isolate slop tanks (only for combination

carriers)

N/A

9.1.1.1.9 Satisfactory tank ventilation arrangements are provided N/A

9.1.1.1.10 Satisfactory arrangements for purging of empty tanks are provided N/A

9.1.1.1.11 Number and location of pressure-vacuum devices N/A

9.1.1.1.12 Satisfactory means are provided for continuously indicating the inert gas temperature and pressure at the discharge side of blowers, when they

are operating

N/A

9.1.1.1.13 Instrumentation and alarms as per operating and service manual are

provided

N/A

9.1.1.1.14 A close ullage system is provided N/A

9.1.1.2 Instruments for measuring oxygen and flammable vapours concentration

in the inert gas / cargo tank

N/A

9.1.1.2.1 Number, manufacturer and type of portable explosion meters N/A

9.1.1.2.2 Number, manufacturer and type of portable oxygen level meters N/A

9.1.1.2.3 Number and location of flue gas isolating valves (only for flue gas systems)

N/A

9.1.1.2.4 Number and location of fuel oil pumps (only for gas generator and gas turbines systems)

N/A

9.1.1.2.5 Manufacturer and type of oxygen content indicator and recorder in cargo

control room

N/A

9.1.1.2.6 Manufacturer and type of oxygen content meter in machinery control

room

N/A

9.1.1.2.7 Manufacturer and type of continuous indicating/recording meter of IG pressure for slop tank pressure for combination carrier on bridge

N/A

15 State whether Flue Gas (FG), Gas Generator (GC) or Gas Turbine (GT) is fitted 16 Delete as appropriate.

Page 32: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 32 of 35

9.1.1.2.8 Means of zero and span calibration of both fixed and portable instruments mentioned above

N/A

9.2 Ships carrying dangerous goods (II-2/19)

9.2.1 The ship is intended for the carriage of dangerous

goods

Applicable N.A.

9.2.2 Protective clothing (II-2/19.3.6.1) Applicable N.A.

ID no.

Location Manufacturer Type

1 N/A N/A N/A

2

3

4

9.2.3 Self-contained breathing apparatus (II-2/19.3.6.2) Applicable N.A.

ID no.

Location Type/Manufacturer Low pressure alarm

See 4.1.2

Capacity (liters) Spare capacity

1 muster station #1/#2, main deck,

cabins,

N/A N/A N/A

2

9.2.3.1 Air compressor for filling of air bottles (See 4.1.2.1) Yes No

9.2.4 Fire extinguishers (II-2/19.3.7) Applicable N.A.

Type Location Type Number Capacity

DCP, CO2 extinguishers

(Other)16

9.3 Additional information

Item No. Comment

10 Additional information for ships with helicopter facilities (Reg. II-2/18) and ships with vehicle, Special category and Ro-Ro spaces (Reg. II-2/20)

10.1 Ships with helicopter facilities (Reg. II-2/18)

10.1.1 The ship is fitted with special facilities for helicopters Applicable N.A.

10.1.1.1 Helicopter overall length (D) N/A m

10.1.2 Fire extinguishers (II-2/18.5.1) Applicable N.A.

Item Location Type Number Capacity

Dry powder extinguishers

helideck port, stb,aft,

N/A 6 1,13; 22,7kg

CO2 extinguishers

helideck port, stb,aft,

N/A 4 9 kg

10.1.3 Foam application system (II-2/18.5.1)

Page 33: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 33 of 35

Location Means of supply Discharge rate Operating period

Bell deck 20 LTR

10.1.4 Fire hoses and nozzles (II-2/18.5.1.5)

Location Number of hoses Hose length Number of nozzles

deck area, accommodations,

engine room

16 16

10.1.5 Fire-fighter’s outfits (II-2/18.5.1.6) (for the characteristics, see 4.1)

10.1.5.1 In addition to the requirements Reg.II-2/10.10, two sets should be provided.

10.1.6 Location of the following equipment

Adjustable wrench Blanket, fire resistant

Cutters, bolt 60 cm Hook, grab or salving

Hacksaw, heavy duty complete with 6 spare blades

Ladder

Lift line 5 mm diameter x 15 m in length

Pliers, side cutting

Set of assorted screwdrivers

Harness knife complete with sheath

10.1.7 An operations manual including a description and a checklist of safety precautions, procedures and equipment requirements is provided.

10.2 Ships with vehicle, Special category and Ro-Ro

spaces (Reg. II-2/20)

Applicable N.A.

10.2.1 A fixed fire detection and fire alarm system / a sample extraction smoke detection system (II-2/20.4) )16

Location bridge Manufacturer Maxlogic Type ML-1242

10.2.2 A fixed fire-extinguishing system (II-2/20.6.1) Applicable N.A.

A fixed fire-extinguishing system is fitted. (for the system’s

characteristics, see 5)

10.2.3 A fixed pressure water-spraying system (II-2/20.6.1.4)

Applicable N.A.

A fixed fire-extinguishing system is fitted. (for the system’s characteristics, see 5)

Applicable N.A.

10.2.3.1 Drainage and pumping arrangements sized to remove no less than 125% of the combined capacity of both

the water spraying system pumps and the required number of fire hose nozzles.

Applicable N.A.

10.2.3.2 Stability information being taken the adverse effect upon stability of the added weight and free surface of

water into account in the Stability Booklet approved.

Applicable N.A.

10.2.4 Fire extinguishers (II-2/20.6.2.1) Applicable N.A.

10.2.4.1 Fire extinguishers are spaced not more than 20 m apart on both sides of the space.

Item Type Number Capacity

N/A N/A N/A N/A

10.2.5 Water fog applicators and portable foam (II-2/20.6.2) Applicable N.A.

Page 34: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 34 of 35

Item Type Number Capacity

Water fog applicator N/A N/A N/A

Portable foam applicator N/A N/A N/A

10.2.6 If motor vehicles with compressed hydrogen or natural gas is carried on board two portable gas detectors

provided for all applicable vessels from 2016-01-01 SOLAS 2014 II-20.2.2

Applicable N.A.

10.3 Vessels designed to carry containers on or above the freeboard deck applicable to vessels constructed on or

after 2016-01-01 SOLAS 2014 II-20.2.2

Applicable N.A.

10.3.1 One water mist lance carried Applicable N.A.

10.3.2 For vessels with 5 or more tiers of containers on or

above weather deck 2 mobile water monitors provided if breath of vessel less than 30 meters

Applicable N.A.

10.3.3 For vessels with 5 or more tiers of containers on or above weather deck 4 mobile water monitors provided

if breath of vessel 30 meters or more

Applicable N.A.

10.4 Additional information

Item No. Comment

ML-1242 Addressable detectors, buttons, loop-powered addressable

sounders, interface modules (monitor and

control modules) and analogue addressable gas detectors can be programmed, in order to operate in

cause-effect scenarios and the fire automation can be built in this manner.

The information contained in this record is a correct description of the Safety Equipment on board.

Issued at (place) on (yyyy-mm-dd)

for DNV GL

(name)

Surveyor

Enclosures

Page 35: CEC301a_30566_Dixie Patriot

DNV GL Id No: 30566

Date of issue: (yyyy-mm-dd)

Form code: CEC 301a Revision: 2014-10 www.dnvgl.com Page 35 of 35

11 Equipment renewals, alterations and/or additions effected since the Record was prepared

Item Number

Description Surveyor Port Date

N/A N/A N/A N/A N/A