CDMP-300 - · PDF file301, Punit Indl. Premises, Turbhe Naka, Navi Mumbai - 400 705. Tel. :+91...

1
301, Punit Indl. Premises, Turbhe Naka, Navi Mumbai - 400 705. Tel. :+91 22 6139 3000 (100 lines) Fax :+91 22 2761 8421 E-mail : [email protected] / [email protected] Website: www.contechindia.com Where innovation never stops..... AN ISO 9001,14001 & OHSAS 18001 COMPANY DIGITAL MELTING POINT APPARATUS CDMP-300 CDMP-300 Specifications o Measuring Range of Melting point : Ambient to 300 C o Resolution : 0.1 C o Rate of heating( C/min) : 0.2,0.5, 1, 1.5, 2 3, 4, 5 o o Accuracy : +0.5 C upto 200 C, o o o +0.8 C from 200 C to 300 C o Heating time (50 to 300 C) : 3 mins o Cooling time( 300 to 50 C) : 5 mins Capillary sample tube size : OD 1.4mm, ID 1mm Power Supply : 220 V +/-10%, 50Hz, 100 Watt Dimensions : 400 x 280 x 210 mm Weight : 12.5 kg o Photo Electric detection. o Large Backlite LCD display. o RS-232 Interface. o Measurement of 3 samples simultaneously.(Optional) o Display of initial and final melting points. o Calculation of average value of initial and final melting points. o Platinum resistor sensor for the precise temperature measurement. o Capillary sample tube as stipulated by pharmacopoeia. o Software for computer interface (Optional). Features Specifications and Designs are subject to changes for improvement

Transcript of CDMP-300 - · PDF file301, Punit Indl. Premises, Turbhe Naka, Navi Mumbai - 400 705. Tel. :+91...

Page 1: CDMP-300 - · PDF file301, Punit Indl. Premises, Turbhe Naka, Navi Mumbai - 400 705. Tel. :+91 22 6139 3000 (100 lines) Fax :+91 22 2761 8421 E-mail : info@contechindia.in / sales@

301, Punit Indl. Premises, Turbhe Naka, Navi Mumbai - 400 705. Tel. :+91 22 6139 3000 (100 lines) Fax :+91 22 2761 8421 E-mail : [email protected] / [email protected]: www.contechindia.comWhere innovation never stops.....

AN ISO 9001,14001 & OHSAS 18001 COMPANY

DIGITAL MELTING POINT APPARATUSCDMP-300

CDMP

-300

SpecificationsoMeasuring Range of Melting point : Ambient to 300 C

oResolution : 0.1 C

oRate of heating( C/min) : 0.2,0.5, 1, 1.5, 2 3, 4, 5o o

Accuracy : +0.5 C upto 200 C, o o o +0.8 C from 200 C to 300 C

oHeating time (50 to 300 C) : 3 mins

oCooling time( 300 to 50 C) : 5 minsCapillary sample tube size : OD 1.4mm, ID 1mmPower Supply : 220 V +/-10%, 50Hz, 100 WattDimensions : 400 x 280 x 210 mmWeight : 12.5 kg

o Photo Electric detection.

o Large Backlite LCD display.

o RS-232 Interface.

o Measurement of 3 samples simultaneously.(Optional)

o Display of initial and final melting points.

o Calculation of average value of initial and final melting points.

o Platinum resistor sensor for the precise temperature measurement.

o Capillary sample tube as stipulated by pharmacopoeia.

o Software for computer interface (Optional).