CDMA-DSS I 02 200904 Engineering Specifications-54
-
Upload
jhon-grandez -
Category
Documents
-
view
219 -
download
0
Transcript of CDMA-DSS I 02 200904 Engineering Specifications-54
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
1/54
CDMA-DSS_I_02_200904
Engineering Specifications
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
2/54
Objects
Mastering engineering commissioning flow
Familiarizing with patrol flow and operations
of patrol items
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
3/54
Content
Engineering commissioning flow
Patrol Guide
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
4/54
Engineering Commissioning Flow
1. Project Survey2. Engineering
Installation Design
3. 2nd Environmental
Acceptance Test4. Unpacking
Inspection
5. Hardware Installation
6. Checking and Poweron
7. SoftwareInstallation
8. Preliminary
Acceptance Test
9. Handover
10. Cutover
11. Trial Running
12. Final Acceptance
Test
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
5/54
Contents
Engineering commissioning flow
Patrol Guide
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
6/54
Checking Items for Patrol Guide
Networking, indicator, clock, network equipment,
background system, service version, alarm, call
quality test, hardware implementation quality,
software installation CD check
Billing check
Network situation check
Configuration data check
Performance analysis and system test
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
7/54
Basic Running Situation Check--Hardware
and Networking Check
Board debugging IP address calculation: A.B.C.D
A = 128
B = Office ID*16 + (Rack No. 1)
C = (Shelf No. 1) * 32 + Slot No. D= (CPU No. 1) * 8 + 1
OMP address is fixed:
Active: 128.0.31.1
Standby: 128.0.31.9
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
8/54
Basic Running Situation Check--IGPS
Indicator Status Check
RUN (green indicator): It flashes during proper
running (Flash once every 0.5 seconds)
ALM (red indicator): It is off during proper running, it
is on when the board is faulty. ACT (green indicator): It is on when the board is
active; it is off when the board is standby.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
9/54
Basic Running Situation Check--UPDS
Indicator Status Check
RUN (green indicator): It flashes during proper
running (Flash once every 0.5 seconds)
ALM (red indicator): It is off during proper running, it
is on when the board is faulty. ACT (green indicator): It is on when the board is
active; it is off when the board is standby.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
10/54
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
11/54
Basic Running Situation Check--DOMP
Indicator Status Check
There two CPUs for each board
RUN1 and RUN2 (green indicator): It flashes during
proper running (Flash once every 0.5 seconds)
ALM1 and ALM2 (red indicator): It is off duringproper running, it is on when the board is faulty.
ACT1 and ACT2 (green indicator): It is on when the
CPU is active; it is off when the CPU is standby.
If it is OMP module, then omc2 indicator flashesquickly.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
12/54
Basic Running Situation Check--DSMP
Indicator Status Check
There two CPUs for each board
RUN1 and RUN2 (green indicator): It flashes during
proper running (Flash once every 0.5 seconds)
ALM1 and ALM2 (red indicator): It is off duringproper running, it is on when the board is faulty.
ACT1 and ACT2 (green indicator): It is on when the
CPU is active; it is off when the CPU is standby.
If it is OMP module, then omc2 indicator flashesquickly.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
13/54
Basic Running Situation Check--DUIM
Indicator Status Check
RUN (green indicator): It flashes during proper
running (Flash once every 0.5 seconds)
ALM (red indicator): It is off during proper running, it
is on when the board is faulty. ACT (green indicator): It is on when the board is
active; it is off when the board is standby.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
14/54
Basic Running Situation Check--Foreground
Board Log Check
1. Open PDS OMC File Management window as
shown below.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
15/54
Basic Running Situation Check--Foreground
Board Log Check
2. Right-click File Management, and choose Board
Maintenance as shown below.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
16/54
Basic Running Situation Check--Foreground
Board Log Check
3. Input Unit Name, e.g., OMP; input Unit Type, e.g.,
OMP; choose 65535 as Unit ID. Do not modify
other values.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
17/54
Basic Running Situation Check--Foreground
Board Log Check
4. In File Management, there is added OMP unit
node. After clicking OMP, the DOC0 and IDE0
folder appears, as shown below.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
18/54
Basic Running Situation Check--Foreground
Board Log Check
5. Choose DOC0, and the corresponding files and
folders under DOC0 appear on the right pane.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
19/54
Basic Running Situation Check--Foreground
Board Log Check
6. Right-click Exc_pp.txt, and choose Copy, as
shown below.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
20/54
Basic Running Situation Check--Foreground
Board Log Check
7. From File Management on the left, choose the local node,
and choose the disk array for saving it.
8. On the blank space on the right, right-click to choose Paste
and complete file copying, as shown below.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
21/54
Basic Running Situation Check--Foreground
Board Log Check
9. Logs under /IDE0/EXCINFO on each board are as
follows.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
22/54
Basic Running Situation Check--Clock Check
On the Clock Management interface, query whether the
current clock of foreground OMP is correct. If it is incorrect,
please configure the current clock of OMP during safe hour as
shown below.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
23/54
Basic Running Situation Check--Alarm Box
Check
Check whether the sound alarming function of the
alarm box has been enabled; it is not allowed to be
set as mute status. The alarm information should
be reported to the alarm box, and the alarm short
messages can be normally sent to the mobile
phones of the maintenance engineers.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
24/54
Basic Running Situation Check--Equipment
Room Environment Check
Check the temperature, humidity, and dust in the
equipment room. Check whether the fans on central
rack are running normally.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
25/54
Basic Running Situation Check--Network
Equipment Check
Switch Check
Checking methods:
1. Switch indicator is flashing normally;
2. The indicator on each port connecting to networkcable is flashing normally;
3. Whether the cascading port has been configured;
4. Whether there are 3 cascading cables;
5. Whether the network cable from other system is
directly connected to DSS system.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
26/54
Basic Running Situation Check--Network
Equipment Check
Router and Firewall Check
Checking methods:
1. RUN indicator is flashing normally;
2. The indicator on each port connecting to networkcable is flashing normally.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
27/54
Basic Running Situation Check--Background
System Check
Windows System Check
System patch check: Query the attribute on My
Computer, and Windows 2000 should install SP4 or
above.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
28/54
Basic Running Situation Check--Background
System Check
SQL Server2000 Patch Check
Open Enterprise Management, and query SQL
Server attribute. In the figure below, the red circle
indicates SQL Server patch No.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
29/54
Basic Running Situation Check--Background
System Check
RPC Patch Check In Start > Run, input regedit to enter the registry table; Open
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Updates\Wind
ows 2000 ; If the item in red cannot be found in the registry table,
please install Microsoft RPC patch.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
30/54
Basic Running Situation Check--Background
System Check
Sasser.wormPatch Check1. In Start> Run, input regedit to enter the registry table.2. Open HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Updates\Windows
2000.
If the item in red cannot be found in the registry table, please install Microsoft
sasser.worm patch.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
31/54
Basic Running Situation Check--Background
System Check
Virtual Memory Check Query the attribute ofMy computer, and click
Advanced > Performance > options > Modify. The
virtual memory should be set as 1.5 times of the
physical memory, and it should not exceed 2G.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
32/54
Basic Running Situation Check--Background
System Check
Query & Record SQL Minimum Query Memory Run SQL Server Enterprise Manager, and query the
attributes of SQL Server. The minimum query
memory should be set to 2048.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
33/54
Basic Running Situation Check--Background
System Check
Installation of Unauthorized Software Check
In the system, except for the operating system,
database system, version software, anti-virus
software and other mandatory software, other
irrelevant software shall not be installed.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
34/54
Basic Running Situation Check--Background
System Check
Mini-computer System Check
Solaris
1. Check system version
2. Check disk space3. Check network configuration
4. Check the local mirroring
5. Check the booting disk information (Performed
during safe hours)
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
35/54
Basic Running Situation Check--Background
System Check
Mini-computer System Check
Aix
1. Check system version
2. Check disk space3. Check network configuration
4. Execute errpt a to check system error (used only
for IBM mini-computer).
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
36/54
Basic Running Situation Check--Background
System Check
Oracle Database Check
1. Oracle version
2. SGA size
3. Table space4. oradism attribute
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
37/54
Basic Running Situation Check--Background
System Check
Cluster Software Check
VCS
1. Check MEM module
2. Check heartbeat3. Check the running status
4. Cluster changeover test
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
38/54
Basic Running Situation Check--Background
System Check
Cluster Software Check
HACMP
1. Check HACMP status
2. Cluster changeover test
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
39/54
Basic Running Situation Check--Background
System Check
Cluster Software Check
TurboHA
1. Display cluster and service status
2. Cluster resource changeover
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
40/54
Basic Running Situation Check--Background
System Check
Auto-Start Setting of PHR Single-computer and
DAS Single-computer Check
1. Verifying restarting of PHR single computer (solaris
system).
2. Verifying restarting of DAS single computer.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
41/54
Basic Running Situation Check--Service
Version Check
PDS Version Check
PDS Foreground Version Check:
In 3GPlatform Version Management Version Query,
check whether all the version files on OMP are
consistent with the background version.
PDS boot Version Check
Telnet to the foreground board, run TestMenu, and
record the running result.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
42/54
Basic Running Situation Check--Service
Version Check
PHR Version Check
PHR Service Version Check
Log onto PHR server as root user, and enter PHR
installation directory/phrsys/zte.corp/zxphr. Check the
version No. in zxphr.cfg, in which Version = is thecurrent PHR version No. The command is as below:
#cd /phrsys/zte.corp/zxphr
#more zxphr.cfg
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
43/54
Basic Running Situation Check--Service
Version Check
PHR Version Check
PHR Database Version Check
Log onto the agent console, and select Help > About
menu. In the About This Product window, press shift
and click the ZTE icon, to display the complete versionNo. .
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
44/54
Basic Running Situation Check--Service
Version Check
DAS Version Check
Log onto the management console, and choose the
menu System > System Information to enter the
tab of system information, to check the major version
No. Press shift+F5 to check the build version No. .
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
45/54
Basic Running Situation Check--Alarm Check
PHR Alarm
In OMC fault management, query the current PHR
real-time alarms, and analyze the alarms.
PDS Alarm
In OMC fault management, query the current PDS
real-time alarms, and analyze the alarms.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
46/54
Basic Running Situation Check--Call Test
Private call: Use the Gota mobile terminal to
perform the private call tests.
Group call: Use the Gota mobile terminal to perform
the group call tests.
DAC Initiates the Private Call: The dispatcher logs
onto the dispatching console, and initiates the
private call.
DAC Initiates the Group Call: The dispatcher logs
onto the dispatching console, and initiates the
group call.
Call the Dispatching Console: The mobile terminal
calls the number of dispatching console.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
47/54
Basic Running Situation Check--Hardware
Implementation Quality Check
Switch cascading: Make the cascading according to the requirement of
dual-computer structure.
Rack grounding:
The grounding should comply with the requirement.
Converter (4-to-1, 8-to-1):
The interface can be changed over normally. After
changeover, perform operations on the host.
Label on Ethernet cable:
The label should be pasted according to therequirement, and should be clear.
Label on power cable:
The label should be pasted according to the
requirement, and should be clear.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
48/54
Accounting Check
FTP CDR Check
Check whether the billing files under/billhand/ftp
have been collected by the billing center.
BILLSAVE CDR Check
Check whether the billing files have been backed up
under/billhand/billsave.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
49/54
Network Situation Check
Switch Configuration Check
Check it as per the specified specifications.
Analysis of Switch Logs
Collect the switch logs, and analyze whetherthere is any abnormal log.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
50/54
Data Check
PDS Configuration Data Check
Check whether the configuration of PDS is
consistent with the plan and true.
PHR Configuration Data Check
1. Check IP address configuration.
2. Check route configuration.
3. Check listener.ora and tnsnames.ora files
configuration.
4. Check ipmp.targets files configuration under Solaris
system.
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
51/54
Data Check--DAS Configuration Data Check
Check the OS version of DAS server: Check OS Time & Timezone
Check whether the default gateway is configured correctly
Check whether NAT IP is configured correctly
Check IP Address of PHR Database
tomcat Port No. Check whether positioning service is supported
Confirm whether the onsite positioning server can be used
normally
Check configuration of DAS and PDS Parameters
Check SMS related configuration
Check SMS and SMSC interconnection related configuration
Check configuration of user sending short message to
dispatching console
Check PC environment detection tool related configuration
Check timer configuration
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
52/54
OMC Check
Check whether the actual timer, date and timezone on OMC
server is consistent with local time
Check whether the daylight saving time is configured
according to the local plan
Check the space size for alarm backup directory and logbackup directory
Check the DB resource
Scheduled Task Setting in DB Table Set
External Clock Source Configuration
PDS SNTP Configuration
Per-defined Task of Performance Statistics
Alarm Box Configuration
CORBA Configuration
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
53/54
Performance Analysis and System Test
PDS performance statistics analysis
PDS foreground board changeover test
PHR disaster recovery single computer
availability test
-
7/28/2019 CDMA-DSS I 02 200904 Engineering Specifications-54
54/54