CDE Poster 2007

1
HMF Flange Riser Joint New Composite Material Marine Riser KT Riser Tensioner Ring SDL Tensioner Support Ring with Optional Fluid Bearing MR Riser Coupling Capital Drilling Equipment Termination Joint Mudmat Guide Base BOP Stack Annular Preventer Intermediate Flex Joint True metal-to-metal sealing Patented passive casing hanger load support design with a load carrying capacity of more than 7 million lb. High capacity, fatigue resistant Conductor housing to High Pressure housing interface Seal fully energized by running tool Generous flow-by area with large particle size clearance Complies with industry standards, API 17D, NACE MR- 01-75; design certified by Lloyds VX/VT dual metal-to-metal gasket prep MS-700 Subsea Wellheads Diverter Insert Diverter Housing Telescopic Joint SingleFlex Joint with Riser Adapter SHD-H4 Connector E x F HAR (High Angle Release) H4 Connector SMS-700 Subsea Wellhead 18-3/4” - 15,000 psi Technology at Work vetco TM Vetco Gray TM H-4 Family of Subsea Wellhead Connectors for wellhead, BOP and LMRP applications 355 ° of contact area in lock profile Dual hydraulic operating system Self-aligning connector to wellhead interface Reliable metal-to-metal VX/VT sealing Hydrate protection system H-4 Connectors Ideal for deep water applications where high load operating conditions exist Stepped diameter design of pin and box simplifies engagement, even with severe vessel movement No loose parts, preventing bolt loss and potential thread damage Field removable and replaceable nose piece Locking bolts preloaded in excess of rated coupling loads to extend fatigue load of riser system HMF Riser Coupling MR-6 Riser Coupling Easy stabbing, fast makeup, and positive alignment Suitable for operating in water depths up to 7,500 ft depending on environmental and well control conditions; MR-10 designs can operate in depths to 10,000 ft. Preloaded connection significantly reduces the range of alternating stresses induced by cyclic loading and improves fatigue life Primary load path for tensile and bending loads is through the dogs and into the body and does not impact actuating screws Telescopic Joint is run and pulled through the rotary table without disconnecting the tensioning lines from riser tensioning ring Riser tensioning lines remain properly spaced out at all times Hydraulic piping for lockdown/storage dogs remains permanently connected Hydraulically disconnects from telescopic joint and locks to a mating profile on the bottom of the diverter housing for convienent, out-of-the-way storage SDL Tension Ring KT Tension Ring Forms a termination point between the riser tensioner and the marine riser system Simplifies running and retrieving marine riser by eliminating makeup/breakout of tensioner lines and hydraulic hoses in the moon pool area Choke, kill, and auxiliary line terminations permanently connected Orientation pins on the ring engage slots in telescopic joint line termination housing for easy makeup Permanently installed tensioner lines maintain proper orientation with rig drilling tensioners Gimbal Gimbal shock absorber supports up to 2,000,000 lb and gimbals when the riser is positioned in the spider Reduces impact loads when running and landing marine riser joints Available for MR-6E, MR-6H SE, and HMF riser systems Maximum rated riser tensile load capacity in locked position Hydraulic latch release for inner and outer barrels available Dual split/solid packer elements Fixed or rotating integral tensioner rings Prepped for non-integral SDL, SDC and KT tensioning rings Fluid or roller bearing prep Single Flex Joint Installed in the LMRP below the riser/BOP Stack Interface Uses a combination elastomeric bearing and seal unit to eliminate the need for a pressure balanced ball and socket interface with seals Up to 2 million lb tensile load capacity Rated for H2S service and oil-based drilling mud Angular deflection to 10 degrees on either side of its axial center while subjected to tensile loading and internal pressures up to 3,000 psi Pressure balance and lubrication systems not required Installed below the telescopic joint Up to 2.5 million lb tensile load capacity Angular deflection to 20 degrees on either side of its axial center while subjected to tensile loading and internal pressure of 1,500 psi The marine riser handling spider supports the marine riser string while the next joint is removed or installed. A positive locking device prevents accidental release. MR-6E Hydraulic Spider MR-6H SE Spider The MR-6H SE riser handling spider supports the riser string on hydraulic sliding dogs. Six hydraulic units move the cam ring up and down to make or break the connector. HMF Riser Spider The HMF hydraulic-gate riser handling spider is used when running or retrieving HMF riser joints through the rotary table. Split gates, operated by hydraulic cylinders, support the riser string when the gates are in the closed and locked position. KFDJ Diverter Fixed support housing, allows installation of outlets up to 20" diameter Diverter, spacer spool and overshot packer assembly may be pulled or run without connecting or disconnecting the flowline, fill-up line and vent lines. The overshot packer on the bottom of the diverter spacer spool assembly reduces the nipple-up time normally required to weld flanges or hubs to casing. Available with a rotating insert which provides low pressure packoff on the kelly or drill pipe during drilling. KFDJ Diverter MR-6E Hydraulic Spider MR-6H SE Spider Gimbal Telescopic Joint CSO Diverter Used on the majority of floating rigs Complete open-hole shutoff with 20” through-bore Rated 1,000 psi for closure on 5” drill pipe; 500 psi for closure on open hole 10 second closing time on pipe or open hole Housing accommodates large diameter riser buoyancy modules High capacity systems available for supporting the Riser String from Diverter Housing in emergency hangoff situations KFDS-CSO Diverter Intermediate Flex Joint HMF Riser Coupling MR-6H SE Riser Coupling MR-6H SE Riser Coupling Automated make-up with minimal personnel intervention Utilizes reliable, field proven concepts and profiles (H- 4 & MR) High preload / efficient load path Parts subject to wear are easily replaceable Easy maintenance, service and inspection with all critical areas readily accessible External surfaces of pin and box can be fully “TSA protected” Handling spider modularized to allow quick change out of critical parts or subassemblies, if required.

description

cdf

Transcript of CDE Poster 2007

Page 1: CDE Poster 2007

HMF FlangeRiser Joint

New Composite Material Marine Riser

KT Riser Tensioner Ring

SDL Tensioner Support Ringwith Optional Fluid Bearing

MR Riser Coupling

Capital Drilling Equipment

TerminationJoint

Mudmat

Guide Base

BOP Stack

Annular Preventer

Intermediate Flex Joint

♦True metal-to-metal sealing

♦Patented passive casing hanger load support design

with a load carrying capacity of more than 7 million lb.♦High capacity, fatigue resistant Conductor housing to

High Pressure housing interface♦Seal fully energized by running tool

♦Generous flow-by area with large particle size

clearance♦Complies with industry standards, API 17D, NACE MR-

01-75; design certified by Lloyds♦VX/VT dual metal-to-metal gasket prep

MS-700 Subsea Wellheads

DiverterInsert

DiverterHousing

Telescopic Joint

SingleFlex Jointwith Riser Adapter

SHD-H4 Connector

E x F HAR(High Angle Release)

H4 Connector

SMS-700 Subsea Wellhead18-3/4” - 15,000 psi

Technology at Work vetcoTMVetco Gray TM

♦H-4 Family of Subsea Wellhead

Connectors for wellhead, BOP and LMRP applications

♦355 ° of contact area in lock profile

♦Dual hydraulic operating system

♦Self-aligning connector to wellhead

interface♦Reliable metal-to-metal VX/VT sealing

♦Hydrate protection system

H-4 Connectors

♦Ideal for deep water applications where high load

operating conditions exist♦Stepped diameter design of pin and box simplifies

engagement, even with severe vessel movement♦No loose parts, preventing bolt loss and potential

thread damage♦Field removable and replaceable nose piece

♦Locking bolts preloaded in excess of rated coupling

loads to extend fatigue load of riser system

HMF Riser Coupling

MR-6 Riser Coupling

♦Easy stabbing, fast makeup, and positive alignment

♦Suitable for operating in water depths up to 7,500 ft

depending on environmental and well control conditions; MR-10 designs can operate in depths to 10,000 ft.

♦Preloaded connection significantly reduces the range

of alternating stresses induced by cyclic loading and improves fatigue life

♦Primary load path for tensile and bending loads is

through the dogs and into the body and does not impact actuating screws

♦Telescopic Joint is run and pulled through the rotary

table without disconnecting the tensioning lines from riser tensioning ring

♦Riser tensioning lines remain properly spaced out at

all times♦Hydraulic piping for lockdown/storage dogs remains

permanently connected♦Hydraulically disconnects from telescopic joint and

locks to a mating profile on the bottom of the diverter housing for convienent, out-of-the-way storage

SDL Tension Ring

KT Tension Ring

♦Forms a termination point between the riser tensioner

and the marine riser system♦Simplifies running and retrieving marine riser by

eliminating makeup/breakout of tensioner lines and hydraulic hoses in the moon pool area

♦Choke, kill, and auxiliary line terminations permanently

connected♦Orientation pins on the ring engage slots in telescopic

joint line termination housing for easy makeup♦Permanently installed tensioner lines maintain proper

orientation with rig drilling tensioners

Gimbal♦Gimbal shock absorber supports up to

2,000,000 lb and gimbals when the riser is positioned in the spider

♦Reduces impact loads when running and

landing marine riser joints

♦Available for MR-6E, MR-6H SE, and HMF riser

systems♦Maximum rated riser tensile load capacity in

locked position♦Hydraulic latch release for inner and outer

barrels available♦Dual split/solid packer elements

♦Fixed or rotating integral tensioner rings

♦Prepped for non-integral SDL, SDC and KT

tensioning rings♦Fluid or roller bearing prep

Single Flex Joint

♦Installed in the LMRP below the riser/BOP

Stack Interface♦Uses a combination elastomeric bearing

and seal unit to eliminate the need for a pressure balanced ball and socket interface with seals

♦Up to 2 million lb tensile load capacity

♦Rated for H2S service and oil-based

drilling mud♦Angular deflection to 10 degrees on

either side of its axial center while subjected to tensile loading and internal pressures up to 3,000 psi

♦Pressure balance and lubrication

systems not required

♦Installed below the telescopic joint

♦Up to 2.5 million lb tensile load capacity

♦Angular deflection to 20 degrees on either side of its

axial center while subjected to tensile loading and internal pressure of 1,500 psi

♦The marine riser handling spider supports the

marine riser string while the next joint is removed or installed. A positive locking device prevents accidental release.

MR-6E Hydraulic Spider

MR-6H SE Spider

♦The MR-6H SE riser handling spider supports the

riser string on hydraulic sliding dogs. Six hydraulic units move the cam ring up and down to make or break the connector.

HMF Riser Spider

♦The HMF hydraulic-gate riser handling spider is

used when running or retrieving HMF riser joints through the rotary table. Split gates, operated by hydraulic cylinders, support the riser string when the gates are in the closed and locked position.KFDJ Diverter

♦Fixed support housing, allows installation of outlets up

to 20" diameter♦Diverter, spacer spool and overshot packer assembly

may be pulled or run without connecting or disconnecting the flowline, fill-up line and vent lines.

♦The overshot packer on the bottom of the diverter spacer

spool assembly reduces the nipple-up time normally required to weld flanges or hubs to casing.

♦Available with a rotating insert which provides low

pressure packoff on the kelly or drill pipe during drilling.

KFDJ Diverter

MR-6E Hydraulic Spider

MR-6H SE Spider

Gimbal

Telescopic Joint

CSO Diverter

♦Used on the majority of floating rigs

♦Complete open-hole shutoff with 20” through-bore

♦Rated 1,000 psi for closure on 5” drill pipe; 500 psi for

closure on open hole♦10 second closing time on pipe or open hole

♦Housing accommodates large diameter riser buoyancy

modules♦High capacity systems available for supporting the Riser

String from Diverter Housing in emergency hangoff situations

KFDS-CSO Diverter

IntermediateFlex Joint

HMF Riser Coupling

MR-6H SERiser Coupling

MR-6H SE Riser Coupling

♦Automated make-up with minimal personnel

intervention♦Utilizes reliable, field proven concepts and profiles (H-

4 & MR)♦High preload / efficient load path

♦Parts subject to wear are easily replaceable

♦Easy maintenance, service and inspection with all

critical areas readily accessible♦External surfaces of pin and box

♦can be fully “TSA protected”

♦Handling spider modularized to allow quick change

out of critical parts or subassemblies, if required.