Causes and Cures of Cracking FPA Nov 08

130
11/12/2008 1 Foundation Performance Association Houston Causes and Cures of Cracking in Concrete David Fowler Joe J. King Chair in Engineering The University of Texas at Austin [email protected] 512 232 2575

Transcript of Causes and Cures of Cracking FPA Nov 08

Page 1: Causes and Cures of Cracking FPA Nov 08

11/12/2008 1

Foundation Performance AssociationHouston

Causes and Cures of Cracking in Concrete

David FowlerJoe J. King Chair in EngineeringThe University of Texas at Austin

[email protected] 232 2575

Page 2: Causes and Cures of Cracking FPA Nov 08

11/12/2008 2

Introduction

Concrete is a durable material.

However, it has characteristics and properties that may result in distress manifestations. These manifestations may be caused in the fresh, unhardened state or in the hardened state.

Page 3: Causes and Cures of Cracking FPA Nov 08

11/12/2008 3

If you ask someone a question about concrete…..

• They will probably tell you that all

concrete cracks

• And somewhere in the

conversation they will probably call

concrete “cement”.

Page 4: Causes and Cures of Cracking FPA Nov 08

11/12/2008 4

Cause of Concrete Cracks

• Concrete is very strong in compression

– 28-day compressive strength ranges from about 3000 psi to over 10,000 psi

• But it is weak in tension

– Tensile capacity is about 10% of its compressive strength

Page 5: Causes and Cures of Cracking FPA Nov 08

11/12/2008 5

Source of Tension in Concrete

• External or “Structural” Sources– Gravity loads: dead and live loads

– Lateral loads: wind and seismic

– Loads from subgrade settlement or swelling

• “Internal” Mechanisms– Volume change restraint due to

temperature changes or drying shrinkage

– Expansion due to corrosion of reinforcing steel or deleterious chemical reactions

Page 6: Causes and Cures of Cracking FPA Nov 08

11/12/2008 6

CAUSES OF CRACKING IN PLASTIC CONCRETE

Page 7: Causes and Cures of Cracking FPA Nov 08

11/12/2008 7

Plastic Shrinkage

• Very Rapid Loss of Moisture

Factors are:

–Concrete and air temperature

–Relative humidity

–Wind velocity

• Results in differential volume

change in top layer

Page 8: Causes and Cures of Cracking FPA Nov 08

11/12/2008 8

Plastic Shrinkage

• Moisture migrates to surface.

• “Bleeding” results in moisture on

the surface of concrete caused by

settling of the heavier components

of mixture.

Page 9: Causes and Cures of Cracking FPA Nov 08

11/12/2008 9

• If moisture evaporates faster than

water is being supplied to surface

by bleeding, there is tendency for

reduction in volume near surface.

• Tensile stresses result.

Page 10: Causes and Cures of Cracking FPA Nov 08

11/12/2008 10

Moisture

Drying concrete Contraction causes stresses

Contraction Caused by Evaporation

Page 11: Causes and Cures of Cracking FPA Nov 08

11/12/2008 11

Similar to “Shrunk” Soil

Page 12: Causes and Cures of Cracking FPA Nov 08

11/12/2008 12

Plastic Shrinkage Crack

Page 13: Causes and Cures of Cracking FPA Nov 08

11/12/2008 13

Plastic Shrinkage Cracking

Page 14: Causes and Cures of Cracking FPA Nov 08

11/12/2008 14

CRACKING IN HARDENED CONCRETE

Page 15: Causes and Cures of Cracking FPA Nov 08

11/12/2008 15

Drying Shrinkage

• Long-term change in volume of concrete caused by loss of moisture.

• Shrinkage without restraint results in no stresses.

Page 16: Causes and Cures of Cracking FPA Nov 08

11/12/2008 16

• Restraint can result from:

–Another part of the structure

–Foundation

–Concrete on the interior of a slab, beam or other component which shrinks less than concrete on the exterior.

• Combination of shrinkage and restraint can result in cracking.

• Reinforcing steel can uniformly distribute the cracking.

Page 17: Causes and Cures of Cracking FPA Nov 08

11/12/2008 17

Example of

Drying Shrinkage

Slab length =

20 feet (6m)

Drying shrinkage =

600 microstrains

Shrinkage of slab =

0.15 inches (4mm)

Page 18: Causes and Cures of Cracking FPA Nov 08

11/12/2008 18

Important!

• Reinforcing steel does not prevent cracking

• Rather, it minimizes crack widths by distributing the cracks

• Rather than one wide crack, there will be many narrow cracks

Page 19: Causes and Cures of Cracking FPA Nov 08

11/12/2008 19

COMP TENS

DRYING FACE

DRYING FACE

Theoretical Shrinkage Stresses

Page 20: Causes and Cures of Cracking FPA Nov 08

11/12/2008 20

The The ““Horse RaceHorse Race””

Page 21: Causes and Cures of Cracking FPA Nov 08

11/12/2008 21

Drying Shrinkage

Page 22: Causes and Cures of Cracking FPA Nov 08

11/12/2008 22

Page 23: Causes and Cures of Cracking FPA Nov 08

11/12/2008 23

Page 24: Causes and Cures of Cracking FPA Nov 08

11/12/2008 24

Shrinkage and Cracking

Page 25: Causes and Cures of Cracking FPA Nov 08

11/12/2008 25

Properly Designed Joints

Page 26: Causes and Cures of Cracking FPA Nov 08

11/12/2008 26

Crack at Sawed Control Joint

Page 27: Causes and Cures of Cracking FPA Nov 08

11/12/2008 27

Sawing Joint to Relieve Drying Shrinkage

Sawing Joint to Relieve Drying Shrinkage

Too Late! Crack forms ahead of saw cutting

Too Late! Crack Too Late! Crack

forms ahead of forms ahead of saw saw

cuttingcutting

Page 28: Causes and Cures of Cracking FPA Nov 08

11/12/2008 28

Corrosion of Reinforcement

Page 29: Causes and Cures of Cracking FPA Nov 08

11/12/2008 29

Corrosion of Reinforcement

Cracking

Steel bar Expansive

pressure

Delamination

Rust

Page 30: Causes and Cures of Cracking FPA Nov 08

11/12/2008 30Corrosion of rebar initiated by chlorides (from roadway above)

Spalling of concrete over rebar

CauseSymptom

Page 31: Causes and Cures of Cracking FPA Nov 08

11/12/2008 31

Chemical Reactions

• Between cement paste and

aggregate

• Between sulfates in water or soil

and cement paste

Page 32: Causes and Cures of Cracking FPA Nov 08

11/12/2008 32

Alkali-SilicaReaction

• Caused by reaction of alkalies in cement with silica aggregates

Page 33: Causes and Cures of Cracking FPA Nov 08

11/12/2008 33

ASR Cracking

Page 34: Causes and Cures of Cracking FPA Nov 08

11/12/2008 34

ASR Cracking

Page 35: Causes and Cures of Cracking FPA Nov 08

11/12/2008 35

ASR: Note Gel Around Stone

Page 36: Causes and Cures of Cracking FPA Nov 08

11/12/2008 36

Swelling/Shrinkage of Soil Beneath Slab

Page 37: Causes and Cures of Cracking FPA Nov 08

11/12/2008 37

Causes

• Settlement of fill

• Differential movement of foundation– During wet season, clay soil beneath

edge of slab gets wet, swells and lifts outside edge of slab

– During drought, soil shrinks around edge of slab and allows edge of slab to drop

– Walls are put under stress and often crack

Page 38: Causes and Cures of Cracking FPA Nov 08

11/12/2008 38

Settlement of Foundation on FillSettlement of Foundation on Fill

1) Settlement of the underlying soils (typically due to

inadequately compacted fill material used to raise

site grade during construction)

Page 39: Causes and Cures of Cracking FPA Nov 08

11/12/2008 39

Typical Foundation on GradeTypical Foundation on Grade

Page 40: Causes and Cures of Cracking FPA Nov 08

11/12/2008 40

Damage Due to Seasonal DryingDamage Due to Seasonal Drying

2) Shrinkage or swelling of the underlying soils

resulting from moisture changes

Page 41: Causes and Cures of Cracking FPA Nov 08

11/12/2008 41

SlabWet conditions

Dry conditions

Differential Settlement

Page 42: Causes and Cures of Cracking FPA Nov 08

11/12/2008 42

Damage Due to Site DrainageDamage Due to Site Drainage

2) Shrinkage or swelling of the underlying soils

resulting from moisture changes

Page 43: Causes and Cures of Cracking FPA Nov 08

11/12/2008 43

Damage Due to TreesDamage Due to Trees

Page 44: Causes and Cures of Cracking FPA Nov 08

11/12/2008 44

Poor Construction Practice

• Adding excess water to mixture

• Inadequate consolidation

• Improper placement of steel

• Inadequate cover

• Omitted rebars

• Improper consolidation of fill beneath slad

Page 45: Causes and Cures of Cracking FPA Nov 08

11/12/2008 45

Inadequate Design

• Inadequate thickness

• Inadequate reinforcing

• Incorrect geometry

• Incorrect use of materials

• Incorrect detailing

Page 46: Causes and Cures of Cracking FPA Nov 08

11/12/2008 46

Case StudyCase Study

• Cracking in swimming pool

Page 47: Causes and Cures of Cracking FPA Nov 08

11/12/2008 47

• Note separation

at outside curve

• Only location of

cracking in brick

at inside of

headers

Page 48: Causes and Cures of Cracking FPA Nov 08

11/12/2008 48

• Note location of

beginning of

crack at point of

tangency

Page 49: Causes and Cures of Cracking FPA Nov 08

11/12/2008 49

Top of concrete wall moved out about ¾inch—no steel in top of wall

Page 50: Causes and Cures of Cracking FPA Nov 08

11/12/2008 50

What was the cause?

• Soil movement?

• ASR?

• Thermal expansion?

• Moisture expansion?

• Other?

Page 51: Causes and Cures of Cracking FPA Nov 08

11/12/2008 51

Most Likely Cause….

• Moisture and thermal expansion of

brick

• As brick expanded the radius got

larger

• Nothing to prevent outward

movement except wall and top of

wall was missing vertical steel

Page 52: Causes and Cures of Cracking FPA Nov 08

11/12/2008 52

• Outward force was large enough to

shear concrete

• Inside corners were restrained from

moving outward by sidewalk

Page 53: Causes and Cures of Cracking FPA Nov 08

11/12/2008 53

Scientific Method of Determining Cause of Cracking

• State problem

• Make observations

• Form hypotheses (possible causes)

• Test the hypotheses by performing tests, making calculations, making more extensive observations, etc.

• Analyze the results and iterate if necessary

• Form conclusions

Page 54: Causes and Cures of Cracking FPA Nov 08

11/12/2008 54

Tests

High Evap. Rate X

Restraint X

Petrographic exam X

Cracking pattern X O X O O

Structural analysis O X

O Supports hypothesis

X Does not support

Plast

ic sh

rinka

ge

Dryin

g Shrin

kage

Alkali-

Silica R

eactio

n

Possible Causes

ExampleEvaluation of Cracking

Ove

rload

Diff. S

ettle

ment

Page 55: Causes and Cures of Cracking FPA Nov 08

11/12/2008 55

Crack Measurement

Page 56: Causes and Cures of Cracking FPA Nov 08

11/12/2008 56

Reading Cracks

• Orientation

• Location

• Length

• Width

• Depth

• Shape

• Frequency

• Age

Page 57: Causes and Cures of Cracking FPA Nov 08

11/12/2008 57

Pure Tension

T T

Page 58: Causes and Cures of Cracking FPA Nov 08

11/12/2008 58

Indirect Tension

Page 59: Causes and Cures of Cracking FPA Nov 08

11/12/2008 59

Pure Shear

Page 60: Causes and Cures of Cracking FPA Nov 08

11/12/2008 60

Combined Shear and Axial Stress

Mohr’s circle

θ

(σx, τ )

σ1

τ

σx

σ1

Page 61: Causes and Cures of Cracking FPA Nov 08

11/12/2008 61

Example: shear wall

Page 62: Causes and Cures of Cracking FPA Nov 08

11/12/2008 62

Two Most Likely Causes

• Differential settlement: check levels

• Lateral force due to

wind/earthquake: check history and

perform structural analysis

Page 63: Causes and Cures of Cracking FPA Nov 08

11/12/2008 63

Observations/Tests

Evaporation rate X

Floor levels O

Crack orientation X O O

Structural analysis X

Plast

ic sh

rinka

ge

Settlem

ent

Latera

l Lo

ad

Possible Causes

Matrix Evaluation

Page 64: Causes and Cures of Cracking FPA Nov 08

11/12/2008 64

Example: wall supporting slab

• Footing and wall cast

• Several weeks later, slab placed and tied to wall

• Few weeks later cracks appeared

wall

End of wall

footing

slab

Page 65: Causes and Cures of Cracking FPA Nov 08

11/12/2008 65

Likely cause: shrinkage in slab

Page 66: Causes and Cures of Cracking FPA Nov 08

Repair of CracksRepair of Cracks

Page 67: Causes and Cures of Cracking FPA Nov 08

11/12/2008 67

Should a Crack be Repaired?

• Considerations:

– Structural vs. non-structural

– Crack width and length

– Crack location within a member

– Environmental exposure condition

– Type of member

– Appearance

Page 68: Causes and Cures of Cracking FPA Nov 08

11/12/2008 68

At what point should the width of

a crack be a concern?

Page 69: Causes and Cures of Cracking FPA Nov 08

11/12/2008 69

Criteria found in some homeowner warranties:

1/8 in. to 1/4 in.

Width of crack before Homebuilder has an obligation

to repair a crack, depending on location of crack

Page 70: Causes and Cures of Cracking FPA Nov 08

11/12/2008 70

Research has shown that load transfer due to aggregate interlock is almost fully

effective across cracks of 0.025 in. or less. Load transfer across cracks of 0.035 in. is good, but not fully effective.

If the only criteria is load

transfer across the crack:

Source: PCA Research Bulletin DX124, Aggregate Interlock at Joints in Concrete Pavements,

Colley and Humphry, 1967

0.025 in.

Page 71: Causes and Cures of Cracking FPA Nov 08

11/12/2008 71

However, the durability of the concrete member is usually as important as the load transfer characteristics. Durability is

enhanced by preventing moisture from reaching embedded

reinforcing steel.

Page 72: Causes and Cures of Cracking FPA Nov 08

11/12/2008 72

Exposure ConditionTolerable Crack

Width

Dry air or protective

membreane0.016 in.

Humidity, moist air, or

soil0.012 in.

Deicing chemicals 0.007 in.

Seawater; wetting and

drying0.006 in.

Water retaining

structures0.004 in.

Tolerable Crack Widths for Conventionally Reinforced Concrete Members1

1 ACI 224R-90, Table 4.1

Page 73: Causes and Cures of Cracking FPA Nov 08

ROUTINGAND SEALING

Page 74: Causes and Cures of Cracking FPA Nov 08

11/12/2008 74

Routing and Filling

• Scabbler (crack chaser) routs crack 1 in. (25 mm) wide and 1-2 in. deep

• Fill with dry sand

• Saturate with monomer/resin

• Good for dirty cracks

• Labor intensive

Page 75: Causes and Cures of Cracking FPA Nov 08

11/12/2008 75

Routing and Sealing

Crack

1-2” (25-50 mm)

or deeper

1” (25 mm)

Polymer

mortar

or sealant

Routed area

Page 76: Causes and Cures of Cracking FPA Nov 08

11/12/2008 76

Routing Crackswith Crack Chaser

Page 77: Causes and Cures of Cracking FPA Nov 08

11/12/2008 77

Cart to Apply Sand

to Crack

Page 78: Causes and Cures of Cracking FPA Nov 08

11/12/2008 78

Applying Monomer

• Clean crack is filled

with dry, clean sand

• High molecular weight

methacrylate is

poured over the sand

with this high tech

applicator

• Cures in about 20

min.

Page 79: Causes and Cures of Cracking FPA Nov 08

11/12/2008 79

Repaired Crack

Page 80: Causes and Cures of Cracking FPA Nov 08

Gravity Filled

Page 81: Causes and Cures of Cracking FPA Nov 08

11/12/2008 81

Filled Crack

~ 0.2 mm at Top

Page 82: Causes and Cures of Cracking FPA Nov 08

11/12/2008 82

RECRACKING

Recracked Slab—Broke Outside of Repair

Page 83: Causes and Cures of Cracking FPA Nov 08

11/12/2008 83

Applying HMWM to Cracked I-20 Bridge

Page 84: Causes and Cures of Cracking FPA Nov 08

11/12/2008 84

Applying HMWMwith Spray Bar

Page 85: Causes and Cures of Cracking FPA Nov 08

11/12/2008 85

Applying Sand

Page 86: Causes and Cures of Cracking FPA Nov 08

11/12/2008 86

Area repaired with

flood coat treatment

Area repaired by individual

crack treatment

Comparisonof Application Methods

Page 87: Causes and Cures of Cracking FPA Nov 08

Case Study: Cracking in Case Study: Cracking in

Tank Farm WallsTank Farm Walls

Page 88: Causes and Cures of Cracking FPA Nov 08

11/12/2008 88

Case Study: Tank Farm WallsCase Study: Tank Farm Walls

• Containment walls (200 ft. x 200 ft.) for diesel fuel tanks showed considerable cracking.

• The owner was concerned that:

– The cracking would permit fuel oil spills to

leak through the walls

– The cracks might seriously reduce the

strength

– The cracking might continue

Page 89: Causes and Cures of Cracking FPA Nov 08

11/12/2008 89

Investigation

• Walls were shown be cast monolithically cast with strip footing.

• However, it was stated that walls were cast one or two months after footings were placed.

• A shear key and “L-shaped” rebarswere used.

Page 90: Causes and Cures of Cracking FPA Nov 08

11/12/2008 90

4’-0”

4”

4’-0”

1’-0” 8”

membrane

#5 “L” bars

containment slab

Wall Section

Page 91: Causes and Cures of Cracking FPA Nov 08

11/12/2008 91

Overall View of Tank Farm

Page 92: Causes and Cures of Cracking FPA Nov 08

11/12/2008 92

Cracks in Walls

Page 93: Causes and Cures of Cracking FPA Nov 08

11/12/2008 93

Investigation

• Site visit was made.

• The cracks were mapped.

• Locations along wall and crack widths were measured.

• Construction history was documented.

Page 94: Causes and Cures of Cracking FPA Nov 08

11/12/2008 94

Crack

Survey

Page 95: Causes and Cures of Cracking FPA Nov 08

11/12/2008 95

Summary of Wall Crack Survey

Avg. Crack Spacing

Avg. Crack Width

Total # of Cracks

.00821”.0075”.00825”.00925”

10.5’7.4’8.2’9.1’

14222020

West Wall

South Wall

East Wall

North Wall

Page 96: Causes and Cures of Cracking FPA Nov 08

11/12/2008 96

Footing Cracks

Page 97: Causes and Cures of Cracking FPA Nov 08

11/12/2008 97

Summary of Footing Cracks

• All cracks measured 0.01 in.

• West wall: two cracks

• North wall: none

• East wall: one

• South wall: four

Page 98: Causes and Cures of Cracking FPA Nov 08

11/12/2008 98

Observations

• Cracking was very uniform in width and in spacing in walls.

• There was essentially no cracking in the footings.

• What could the cause of the cracking be?

Page 99: Causes and Cures of Cracking FPA Nov 08

11/12/2008 99

Hypothesis

• Footing was placed first—free to shrink

• Wall was placed one to two months later after most of wall drying shrinkage had taken place

• As wall tried to shrink, it was restrained by rebars that tied wall to footing.

• Remember: no restraint, no cracking.

• Likely cause: drying shrinkage cracking.

Page 100: Causes and Cures of Cracking FPA Nov 08

11/12/2008 100

Hypothesis

• The strain on the north wall, for example, is

20 cracks x 0.00925 in./200 ft. x 12 in.

= 0.000077 in./in.

• Some strain is taken by the cold joints and if

this movement were known the calculated

strain in the concrete would be even higher.

• But this strain is well within anticipated values

of drying shrinkage

Page 101: Causes and Cures of Cracking FPA Nov 08

11/12/2008 101

Recommendations

• The cracking did not reduce the flexural capacity of the walls.

• The biggest concern is the ability of the walls to contain spilled fuel.

• ACI 224 Control of Cracking recommends the following maximum crack widths:

– Humidity, moist air or soil 0.012 in.

– Protective membrane 0.016 in.

– Water retaining structure 0.004 in.

Page 102: Causes and Cures of Cracking FPA Nov 08

11/12/2008 102

Recommendations

• The maximum measured crack width was 0.015 in.

• With a protective membrane, the cracks are adequate.

• The obvious solution is to extend the membrane to the top of the wall; the concrete alone does not have to act as a retention structure.

Page 103: Causes and Cures of Cracking FPA Nov 08

Case Study:Case Study:

Cracked Slab FoundationCracked Slab Foundation

Page 104: Causes and Cures of Cracking FPA Nov 08

11/12/2008 104

Case Study: Cracked Slab on Grade

• One-story wood-framed residence was constructed on concrete slab on grade.

• Construction was during wet weather.

• Cracking was noted in slab within 6 months.

Page 105: Causes and Cures of Cracking FPA Nov 08

11/12/2008 105

Complaints by Owner• “Cracks in walls”

• “Numerous, severe cracks in foundation”

• “Doors not opening properly due to foundation failure”

• “Improper operation of windows due to foundation failures”

• (doors and windows no longer an issue when I made my inspection)

Page 106: Causes and Cures of Cracking FPA Nov 08

11/12/2008 106

Investigation• At request of builder, I made an

inspection approximately three years after slab was constructed.

• The only remaining complaints involved cracks in walls and cracks in foundation.

• Both of these complaints, if valid, suggested that foundation movement was the cause

Page 107: Causes and Cures of Cracking FPA Nov 08

11/12/2008 107

1. Cracks in Walls

• A careful investigation found only five hairline cracks in the gypsum wallboard.

• These cracks were more indicative of shrinkage of the joint compound or shrinkage or expansion of wood framing due to changes in humidity.

Page 108: Causes and Cures of Cracking FPA Nov 08

11/12/2008 108

Page 109: Causes and Cures of Cracking FPA Nov 08

11/12/2008 109

Page 110: Causes and Cures of Cracking FPA Nov 08

11/12/2008 110

Page 111: Causes and Cures of Cracking FPA Nov 08

11/12/2008 111

Page 112: Causes and Cures of Cracking FPA Nov 08

11/12/2008 112

Finding

• Cracks were insignificant and typical of those found in new homes without significant foundation movement.

• Homeowner warranty indicated that small cracks, nail pops, seam lines….should be expected and were not considered to be a defect.

Page 113: Causes and Cures of Cracking FPA Nov 08

11/12/2008 113

So, what could it be??

Page 114: Causes and Cures of Cracking FPA Nov 08

11/12/2008 114

2. Numerous Cracks in Slab

• A visual survey of the slab, which had not been covered, revealed numerous cracks.

• Cracks were sketched on a plan.

• Crack widths were noted.

Page 115: Causes and Cures of Cracking FPA Nov 08

11/12/2008 115

Page 116: Causes and Cures of Cracking FPA Nov 08

11/12/2008 116

• A limited relative foundation survey was performed to determine the out of level of the slab.

Page 117: Causes and Cures of Cracking FPA Nov 08

11/12/2008 117

Page 118: Causes and Cures of Cracking FPA Nov 08

11/12/2008 118

Finding

• Cracking was uniformly distributed throughout the slab.

• Even in areas where there was little difference in elevations.

• In the bedroom wing where the variation in level was only ¼ inch, there was a wide crack in the hall.

• Most of the slab is within ¾ inch.

• Worst unlevel is 1 ¼ in—no wall cracking in that area.

Page 119: Causes and Cures of Cracking FPA Nov 08

11/12/2008 119

0.125-in. in hall in BR wing

Page 120: Causes and Cures of Cracking FPA Nov 08

11/12/2008 120

0.125-in. crack in Living Room

Page 121: Causes and Cures of Cracking FPA Nov 08

11/12/2008 121

• Quite likely that slab was not constructed level.

• If flexural stress due to soil movement existed, curvature of the slab would have to occur that would be associated with an unlevel slab.

• The wall cracking was insignificant.

• If the slab cracking had been caused by foundation movement, much more severe cracking in the wall board would be expected.

Page 122: Causes and Cures of Cracking FPA Nov 08

11/12/2008 122

Summary of Findings

• The two primary indications of significant foundation movement,

– SignIficantly unlevel slabs

– Severe cracks in wallboard

were absent in this house.

Page 123: Causes and Cures of Cracking FPA Nov 08

11/12/2008 123

If not foundation movement, what could cause cracking??

• Plaintiff’s expert cited a number of possible causes:

– Lack of compaction

– Wet conditions at time of placement

– Rapid placement of plastic membrane just

prior to concrete placement

– Voids beneath the slab

– Lack of reinforcement in the beams.

Page 124: Causes and Cures of Cracking FPA Nov 08

11/12/2008 124

• Cores taken by plaintiff’s experts indicated that:

– Concrete was not 4 in. thick as required by

plans

– Bottom of slab was quite irregular

– Voids were found beneath the slab

• Plaintiff’s experts also found that beams were of adequate depth, that wire mesh was found in the slab, and that reinforcing had been used in the beams

Page 125: Causes and Cures of Cracking FPA Nov 08

11/12/2008 125

Findings

• The foundation met the 2000 International Residential Code.

• The slab thickness did not meet the 4-in. thickness specified in the plans.

• The most likely cause of cracking was not foundation movement but drying shrinkage.

Page 126: Causes and Cures of Cracking FPA Nov 08

11/12/2008 126

Recommendations

• Plaintiff’s expert had recommended placing piers beneath the beams.

• My recommendation was to epoxy inject the cracks that were 0.035 in. or wider.

• I further recommended that the builder have the slab checked for voids beneath the slab using ground penetrating radar.

Page 127: Causes and Cures of Cracking FPA Nov 08

11/12/2008 127

Outcome

• The attorneys permitted the experts to meet.

• It was agreed that the recommendations to use epoxy injection be adopted.

• Ground penetrating radar (GPR) was used to locate voids.

Page 128: Causes and Cures of Cracking FPA Nov 08

11/12/2008 128

Voids Using GPRVoids Using GPR

Page 129: Causes and Cures of Cracking FPA Nov 08

11/12/2008 129

Outcome

• The cracks were epoxied in early 2005.

• It is not known if they filled voids beneath the slab.

• In early 2008, plaintiff’s engineer said that they have had no calls or complaints—apparently the fix has worked.

Page 130: Causes and Cures of Cracking FPA Nov 08

11/12/2008 130

Summary

• Concrete cracks

• It can be controlled and in some cases eliminated with proper design

• But cracking provides a life-time annuity for many of you!

• It is very important to determine the cause of cracking before repairs are made