Cathodic Protection for on Grade Storage Tanks and Buried Piping

62

Click here to load reader

description

Cathodic Protection for on Grade Storage Tanks and Buried Piping

Transcript of Cathodic Protection for on Grade Storage Tanks and Buried Piping

Page 1: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Cathodic ProtectionCathodic Protection for Onfor On--Grade Storage Tanks and Grade Storage Tanks and

Buried PipingBuried Piping

John FitzgeraldJohn Fitzgerald CorrproCorrpro

Freshwater Spills SymposiumFreshwater Spills Symposium April 6April 6--8, 20048, 2004

Page 2: Cathodic Protection for on Grade Storage Tanks and Buried Piping
Page 3: Cathodic Protection for on Grade Storage Tanks and Buried Piping

•• Preserve AssetsPreserve Assets •• Reduce Maintenance CostsReduce Maintenance Costs •• Governmental Compliance Governmental Compliance •• Preserve The EnvironmentPreserve The Environment

Why is Corrosion Control Why is Corrosion Control Important?Important?

Page 4: Cathodic Protection for on Grade Storage Tanks and Buried Piping

What I Will Cover….What I Will Cover….

-- Causes of CorrosionCauses of Corrosion -- SPCC/State/OPS RegulationsSPCC/State/OPS Regulations -- Cathodic Protection ApplicationsCathodic Protection Applications -- Maintenance RequirementsMaintenance Requirements

Page 5: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Spill Prevention Control and Spill Prevention Control and Countermeasure (SPCC) RegulationCountermeasure (SPCC) Regulation

(Implementation Required by 2/18/05 ) (Implementation Required by 2/18/05 )

-- Provide buried piping that is installed or Provide buried piping that is installed or replaced after August 16th, 2002 replaced after August 16th, 2002 protective coating and protective coating and cathodiccathodic protection.protection.

-- Should a section of line be exposed for any Should a section of line be exposed for any reason it must be inspected for deterioration. reason it must be inspected for deterioration. If corrosion damage is found you must take If corrosion damage is found you must take additional examination and corrective action.additional examination and corrective action.

with a with a

Page 6: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Federal Level (Breakout Tanks)

a) Relieves surges in a hazardous liquid pipeline system or b) receive and store hazardous liquid transported by a pipeline for reinjection and continued transportation by pipeline

Page 7: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Breakout Tank Piping (DOT)

M

Main Line

Valve

OPS Inspection

MeterM

Product Tank

(Breakout) M

Page 8: Cathodic Protection for on Grade Storage Tanks and Buried Piping

-- Approximately 25% of States now Approximately 25% of States now require require cathodiccathodic protection be installed protection be installed and maintained on new, refurbished, or and maintained on new, refurbished, or repaired tanks in contact with soil or sand repaired tanks in contact with soil or sand foundations. foundations.

-- A number of other states are in the A number of other states are in the process of implementing regulations process of implementing regulations governing AST’s.governing AST’s.

State Level

Page 9: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Terminal Tankage

Main Line

M

Valve

OPS Inspection

MeterM

No OPS Inspection

OPS Inspection Stops (Enforcement Policy)

Loading TerminalProduct

Tank (Terminal)

Product Tank

(Terminal)

Page 10: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Corrosion Can be Defined as Either:

� Practical Tendency of a Metal to Revert to its Native State

� Scientific Electrochemical Degradation of Metal as a Result of a Reaction with its Environment

Page 11: Cathodic Protection for on Grade Storage Tanks and Buried Piping

IRON REFINING MILLING

IRON CORROSION IRON OXIDE

Corrosion - A Natural Process

OXIDE

Page 12: Cathodic Protection for on Grade Storage Tanks and Buried Piping

1) ANODE

2) CATHODE

3) ELECTROLYTE

4) ELECTRICAL CONNECTION

Anode -600mV

Cathode -550mV

-575mV

Page 13: Cathodic Protection for on Grade Storage Tanks and Buried Piping

CorrosionCorrosion ofof MetallicMetallic StructureStructure

Page 14: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Anodic Area ( - )

Current Flow

Cathodic Area ( + )

Structure

Page 15: Cathodic Protection for on Grade Storage Tanks and Buried Piping
Page 16: Cathodic Protection for on Grade Storage Tanks and Buried Piping
Page 17: Cathodic Protection for on Grade Storage Tanks and Buried Piping
Page 18: Cathodic Protection for on Grade Storage Tanks and Buried Piping

SAND CURRENT FLOW

Corrosion Cell on Tank Bottom

CLAY

Steel Tank Floor

ANODEANODECATHODECATHODE CATHODECATHODE

Page 19: Cathodic Protection for on Grade Storage Tanks and Buried Piping

DRY SAND

MOIST SAND

WATER

Corrosion Caused by Poor Water Drainage

Page 20: Cathodic Protection for on Grade Storage Tanks and Buried Piping

New Bottom (Anode)

CURRENT FLOW

SAND

SAND

New Steel Coupled to Old Steel

Old Bottom (Cathode)

Page 21: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Galvanic Anode Cathodic Protection

4 Current is obtained from a metal of a higher energy level

Page 22: Cathodic Protection for on Grade Storage Tanks and Buried Piping

PRACTICAL GALVANIC SERIES Material Potential*

Pure Magnesium -1.75

Magnesium Alloy -1.60

Zinc -1.10

Aluminum Alloy -1.00

Cadmium -0.80

Mild Steel (New) -0.70

Mild Steel (Old) -0.50

Cast Iron -0.50

Stainless Steel -0.50 to + 0.10

Copper, Brass, Bronze -0.20

Titanium -0.20

Gold +0.20

Carbon, Graphite, Coke +0.30

* Potentials With Respect to Saturated Cu-CuSO4 Electrode

Page 23: Cathodic Protection for on Grade Storage Tanks and Buried Piping
Page 24: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Structure

Magnesium

Anode

Current Flow

Galvanic Cathodic Protection on

Coated Pipeline

Page 25: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Cathodic Protection Test Station

Test Station

Magnesium Anode

Coated Pipe

Page 26: Cathodic Protection for on Grade Storage Tanks and Buried Piping

FLANGE INSULATION KIT

INSULATING UNIONS

Page 27: Cathodic Protection for on Grade Storage Tanks and Buried Piping

• Typically limited to new piping, that has a good quality coating and electrical isolation.

• If the particular location is lacking any of the above, an impresses current system may be warranted.

Galvanic Anodes

Page 28: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Anode Cathode

Water / Sediment

Fuel Product

Internal Corrosion

Page 29: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Internal Corrosion

Page 30: Cathodic Protection for on Grade Storage Tanks and Buried Piping
Page 31: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Coating Anode

Bolt

Tank Bottom

Page 32: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Conventional CP Systems for Conventional CP Systems for AST’sAST’s

-- Shallow (Distributed) AnodesShallow (Distributed) Anodes

-- Deep Anode Deep Anode GroundbedGroundbed

Page 33: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Impressed Current Transformer Rectifier UnitImpressed Current Transformer Rectifier Unit

Page 34: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Rectifier

Anode Groundbed

( - ) ( + )

Pipeline (Structure)

Current Flow

Impressed Current System

Page 35: Cathodic Protection for on Grade Storage Tanks and Buried Piping

TankTank

Anode

Splice

Typical Depth 20’

Shallow Anodes

Rectifier

(-)(+)

Page 36: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Shallow Anodes

Tank

Rectifier

(-) (+)

Anode

Page 37: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Anodes

Junction Box

Rectifier

-+

Page 38: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Directional Boring Under Existing AST

Page 39: Cathodic Protection for on Grade Storage Tanks and Buried Piping

ABOVEGROUND STORAGE TANK

CATHODIC PROTECTION

3”∅ PVC 20% Exposure

Anode Material Anode Tube

10’ Typical

Test/Access Station

Grade

Aboveground

Storage Tank

Page 40: Cathodic Protection for on Grade Storage Tanks and Buried Piping

New/Refurbished AST Bottoms with or without Secondary Containment

Page 41: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Secondary Containment

4 Environmental Protection

4 Minimize Liability

4 State and Local Regulations

Page 42: Cathodic Protection for on Grade Storage Tanks and Buried Piping

New Tank Construction with Liner New Tank Construction with Liner

Page 43: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Anode & Reference Cell PlacementAnode & Reference Cell Placement in High Resistance Sandin High Resistance Sand

Page 44: Cathodic Protection for on Grade Storage Tanks and Buried Piping
Page 45: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Liner

Floor

AnodeConduit

CP Installation on Double Bottom TankCP Installation on Double Bottom Tank

Page 46: Cathodic Protection for on Grade Storage Tanks and Buried Piping

New Floor Installation on Existing ASTNew Floor Installation on Existing AST

Page 47: Cathodic Protection for on Grade Storage Tanks and Buried Piping

CP Installation on CP Installation on RebottomedRebottomed TankTank

Page 48: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Installation of CP System on Lifted AST

Installation of CP System on Installation of CP System on Lifted ASTLifted AST

Page 49: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Maintenance of Cathodic Maintenance of Cathodic Protection SystemsProtection Systems

-- Conduct Annual TestingConduct Annual Testing -- Meet NACE Criteria/StandardsMeet NACE Criteria/Standards -- Conduct BiConduct Bi--Monthly RectifierMonthly Rectifier ChecksChecks

-- NACE Qualified TechniciansNACE Qualified Technicians

Page 50: Cathodic Protection for on Grade Storage Tanks and Buried Piping

NACE Cathodic Protection Criteria

• -850mV or more negative with current applied

• -850mV “Instant off” • -100mV shift between “Instant off” and

“Native”

Page 51: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Annual Cathodic Protection Survey

Page 52: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Tank

Rim Potential Measurements

Portable Reference Cell

Soil

(+)

????

--850mV850mV

Page 53: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Rim 25' Center 55' Rim On -1411 -698 -404 -601 -1455 Off -902 -664 -402 -578 -911

Reference Cell

Bullseye®

Monitoring Tube

Test / Access Station

boveground torage Tank

ade

3’ Typical

Potentials (mV)

Page 54: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Test Station

Structure

Stray Current Monitoring Test StationStray Current Monitoring Test Station

Page 55: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Computerized Potential Logging Survey

Reference Cells

Pipeline

Test Station

Backpack Computer Unit

Chainer/Wire Dispenser & Counter

Page 56: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Monitoring

• Record volts and amps s

• Compare values to target setting

• Conduct annual cp survey by NACE engineer

• Maintain cp records

every 30-60 day

Page 57: Cathodic Protection for on Grade Storage Tanks and Buried Piping

BiBi--Monthly Rectifier CheckMonthly Rectifier Check

Page 58: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Visual Check of Volts/AmpsVisual Check of Volts/Amps

Page 59: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Record KeepingRecord Keeping

-- Provides HistoryProvides History -- Computer Records/Data CollectionComputer Records/Data Collection

Remote MonitoringRemote Monitoring Hand Held ComputersHand Held Computers Close Interval SurveysClose Interval Surveys Data PrintoutsData Printouts Flagging of Problem AreasFlagging of Problem Areas Prioritize Action ItemsPrioritize Action Items

-- As Built DrawingsAs Built Drawings -- Store Data & Records for LifeStore Data & Records for Life

Page 60: Cathodic Protection for on Grade Storage Tanks and Buried Piping

System Characteristics

Galvanic Impressed 8No external power 8 External power required 8Fixed driving voltage 8 Voltage can be varied 8Limited current 8 Current can be varied 8Small current requirements 8 High current requirements 8Used in lower resistivity 8 Used in almost any

environment resistivity environment 8 Usually negligible 8 Must consider interference

interference with other structures

Page 61: Cathodic Protection for on Grade Storage Tanks and Buried Piping

Recommended Practices API-651 - Cathodic Protection of Aboveground Petroleum

Storage Tanks:

“Galvanic anodes method is not practical for protection of large bare structures.”

NACE RP0193-01 - External Cathodic Protection of On-Grade Metallic Storage Tanks:

“Galvanic protection systems can be applied to tank bottoms where the metallic surface area exposed to the electrolyte can be minimized through the application of a dielectric coating or the area is small due to the tank size or configuration.”

Page 62: Cathodic Protection for on Grade Storage Tanks and Buried Piping

QuestionsQuestions… …