Category 6A field termination plug - TUK - field...Category 6A field termination plug Category 6A...

3
Category 6A field termination plug Category 6A field termination plug (PGSmc) TUK’s Cat6A field termination plug is the RJ45 plug for time-saving and efficient on-site assembly for all networks, from Voice right through to 10 Gigabit Ethernet. It can be assembled on all standard types of cable, quickly and with no requirement of special tools. Whether in the office, data centre, in industry or in home networks – the Cat6A field termination plug offers flexibility and saves time and money on installation, repairs and maintenance. Features Category 6A Class EA Field Termination Plug, with 568A/B and PNO wiring label Robust industrial fully shielded design Works with solid or stranded cable Suitable for use with a wide range of cable outer diameter and core sizes – 6-9mm cable OD, 22-27 AWG cores (core including insulation up to OD 1.6mm) Reusable (27AWG cable only reusable up to 5 times) No tools required for time saving and efficient termination on site Rated for 750 mechanical cycles Note: not ideal for short length (4m or less) Category 6A patch cords Specifications Materials: o RJ45 plug: housing: nickel plated zinc-alloy, contacts: 50μ”/1.27μm gold plating over phosphor bronze plug cover: ABS, plug latch: POM o RJ45 jack: housing nickel plated zinc-alloy o IDC: housing and cover: PC FR, terminals/contacts: tin plated phosphor bronze o Earthing plate: SUS304 o Strain relief: PP 25/08/2016

Transcript of Category 6A field termination plug - TUK - field...Category 6A field termination plug Category 6A...

  • Category 6A field termination plug

    Category 6A field termination plug (PGSmc) TUK’s Cat6A field termination plug is the RJ45 plug for time-saving and efficient on-site assembly for all networks, from Voice right through to 10 Gigabit Ethernet. It can be assembled on all standard types of cable, quickly and with no requirement of special tools. Whether in the office, data centre, in industry or in home networks – the Cat6A field termination plug offers flexibility and saves time and money on installation, repairs and maintenance.

    Features

    Category 6A Class EA Field Termination Plug, with 568A/B and PNO wiring label

    Robust industrial fully shielded design Works with solid or stranded cable Suitable for use with a wide range of cable outer diameter and core sizes – 6-9mm cable OD, 22-27

    AWG cores (core including insulation up to OD 1.6mm)

    Reusable (27AWG cable only reusable up to 5 times)

    No tools required for time saving and efficient termination on site

    Rated for 750 mechanical cycles

    Note: not ideal for short length (4m or less) Category 6A patch cords

    Specifications Materials:

    o RJ45 plug: housing: nickel plated zinc-alloy, contacts: 50µ”/1.27µm gold plating over phosphor bronze plug cover: ABS, plug latch: POM

    o RJ45 jack: housing nickel plated zinc-alloy o IDC: housing and cover: PC FR, terminals/contacts: tin plated phosphor bronze o Earthing plate: SUS304 o Strain relief: PP

    25/08/2016

  • TUKCode: PGSmcROHS Compliant

    TUK Ltd, Unit 4, Wimbledon Stadium Business Centre, Riverside Road, London, SW17 0BA

    Tel: 020 8946 6688 Fax: 020 8879 7410 Email: [email protected] Website: www.tuk.co.uk

    29/02/16

    screen

    reusable

    Strain relief: PPEarthing plate: SUS304

    Gold

    - Core OD 1.6mm

  • Instruction ManualWhite/OrangeOrange

    White/GreenGreen

    White/GreenGreenBlueWhite/Blue

    BlueWhite/Blue

    White/BrownBrown

    White/OrangeOrange

    White/BrownBrownJ

    AC

    K P

    IND

    ES

    IGN

    AT

    ION

    S 12364578

    TIA / EIAT568B

    YellowOrangeWhiteBlue

    INDUSTRIALTIA / EIAT568A

    Fan out all four twisted pairs, following the color coding label and allocate each conductors into proper slots on wiring cap.Trim the ends of conductors.

    1

    Remove the wiring label before place wiring cap on plug.

    Place the wiring cap onto plug, use plier to clamp wiring cap until it completely snap-in to effect the connection.

    Close plug cover, make sure the drain wire is in proper contact with grounding clip on plug. Pull back strain relief boot to cover the plug, fasten supplied cable tie to secure grounding contact.

    3

    4

    6

    5

    Drain Wire

    Cable Tie

    Insert cable into strain relief boot, strip off 1.2 inch of cable jacket, fold back the drain wire.

    2

    Remove the stopper before installation. Cover Stopper

    Open shielded cap

    Cut off cable tie, remove the boot. Using flat screw driver and pry gently on plug cover one end first and the other end subsequently to open it.

    Unload the cable

    Cut the end of boot to fit your cable OD.Boot adjustment

    Cut off cable tie

    T568A

    T568B

    INDUS

    TRIAL

    T568A

    T568B

    INDUS

    TRIAL

    T568A

    T568B

    INDUS

    TRIAL

    Wiring Label

    Remove boot

    1.2"(30mm)

    N6042TUX7X1601 PGSmcNB. Designed for lengths of 4m or more.Shorter lengths may not have full Category 6A performance