7
THERMEX SOLUTION P/L 16/165 WALDRON RD CHESTER HILL NSW 2162 AUSTRALIA ABN 61150461573 CATALOGUE 2019 P/L

Transcript of catalogue Thermex 2019 - Công ty CN SEILAR Việt Nam

Page 1: catalogue Thermex 2019 - Công ty CN SEILAR Việt Nam

THERMEX SOLUTION P/L16/165 WALDRON RD CHESTER HILL NSW 2162

AUSTRALIA ABN 61150461573

CATALOGUE 2019

P/L

Page 2: catalogue Thermex 2019 - Công ty CN SEILAR Việt Nam

TECHNICAL DATA Designed, manufactured and engineered in Australia

Thermex’s range of heat pumps are designed and manufactured in Australia for both local and international markets. Thermex’s manufacturing resources have over 50 year of experience in manufacturing heat pumps and refrigeration products.

All Thermex’s heat pumps are manufactured from the highest quality components supplied from the industry’s leading suppliers and designed for high effectiency and low maintenance

All Thermex’s evaporators are coated in Blygold PoluAI XT - MB which is a special corrosion protection coating for cooling coils and evaporators. The coating shields vulnerable metals from aggressive environments. The aluminum content in the coating provides the necessary heat con ductivity to ensure the that coated heat exchangers have optimum heat transfer capacity.

Special additives ensure the applied coating lm is bacterial and fungi resistant. After treating evaporators or cooling coils these articles should be considered “treated articles” and be marked as such.

Corrosion resistant

Micro organism resistant

Heat conductive

11000 hours salt spray test

Nano free

Treated article

ASTM B117 – 11000 hours salt spray test

ASTM G85 A1 – 4000+ hours acid salt spray test

The coating is compliant to

Evaporator Coating

THERMEX heat pumps are designed to be provide reliable hot water for any application year-round. Made from rugged stainless steel and using the industries’ leading supplier the THERMEX heat pump is built for years of trouble free service

All unit come with – as standard features

Stainless Steel chassis

Single wall plate heat exchanger

condensers Electronic controller

Hot gas injection for defrost function when

required

High effectiency scroll compressors

Advanced evaporator design for high

effectciency and low refrigerant charge

R134a refrigerant to allow high water

temperatures to be achieved with ease Flow switch to protect the condenser

5 Year warranty on the compressor and the condenser

Staging for up to 8 heat pumps

Phase failure protection

Enable relay for the primary pump

Thermex heat pumps use leading edge evaporator technology on its air forced units. The advanced coil pattern has 7mm tube diameter which is the smallest in the market and the equilateral tube arrangement which creates equal distances between each tube and the six adjacent tubes.

These features result in more tubes per n cross section and this means more primary surface area – the result is higher capacity and lower refrigerant charge

Evaporator Design

Page 3: catalogue Thermex 2019 - Công ty CN SEILAR Việt Nam

Ambient operation range -5 < 45 degreeC

Ambient operation range -5 < 45 degreeC

TECHNICAL DATA Designed, manufactured and engineered in Australia

Model – 30kW 50hz

10° C AmbientConditions

50°C Supply

60°C Supply

70°C Supply

20° C AmbientConditions

50°C Supply60°C Supply70°C Supply

27.2

25.74

24.8

31.3530.6928.08

6.6

6.6

14.3

14.3

3.9

4.65

Heat output KW Power input KW Current draw A/ph COP

30° C AmbientConditions

Motor data

Compressor max current draw - ACompressor - HPFan size – mmFan current draw – A/PhFan wiringNoise rating – dB

Water CircuitWater ttingsPressure drop across unit - dP

Refrigeration circuitRefrigerant charge per circuit – kgNo. refrigerant circuits

19.085002.74Star Y61

1 1/2” FBSP66

3.51

Minimum ow across unit- l/s

Oil charge- per circuit - kg 6.0

1.0

Comp in-rush current - ARated load amps - A No. FansFan power draw - kW

3Air ow - m /hrNo.poles - fan

9813.910.6361004

50°C Supply60°C Supply70°C Supply

36.332.6732.4

6.6 14.3 4.95

Model – 50kW 50hz

10° C AmbientConditions

50°C Supply60°C Supply70°C Supply

20° C AmbientConditions

50°C Supply60°C Supply70°C Supply

42.6740.9540.02

49.0050.3547.00

10.5

10.6

19.8

19.8

3.9

4.75

Heat output KW

30° C AmbientConditions

Motor data

Compressor MCC - ACompressor - HPFan size – mmFan current draw – A/PhFan wiringNoise rating – dB

32.0125005.4Star Y65

Locked rotor amps – ARated load amps - A No. FansFan power draw - kW

3Air ow - m /hrNo.poles - fan

14522.921.26130004

Water CircuitWater ttingsPressure drop across unit - dP

Refrigeration circuitRefrigerant charge per circuit – kgNo. refrigerant circuits

1 1/2” FBSP47

3.5

1

Minimum ow across unit- l/s

Oil charge- per circuit - kg

1.6

6.5

50°C Supply60°C Supply70°C Supply

57.4254.7052.65

10.7 19.8 5.1

Power input KW Current draw A/ph COP

Page 4: catalogue Thermex 2019 - Công ty CN SEILAR Việt Nam

TECHNICAL DATADesigned, manufactured and engineered in Australia

Model – 60kW 50hz

10° C AmbientConditions

50°C Supply60°C Supply70°C Supply

20° C AmbientConditions

50°C Supply60°C Supply70°C Supply

52.0249.8048.24

65.205 9.6656.7

12.3

12.6

23.0

23.0

4.05

4.75

Heat output KW Power input KW

30° C AmbientConditions

Motor dataCompressor MCC - ACompressor - HPFan size – mmFan current draw – A/PhFan wiringNoise rating – dB

32.0154501.8Star Y63

Water CircuitWater ttingsPressure drop across unit - dP

Refrigeration circuitRefrigerant charge per circuit – kgNo. refrigerant circuits

1 1/2” FBSP51

3.5

1

Minimum ow across unit- l/s

Oil charge- per circuit - kg

1.6

6.5

Locked rotor amps – ARated load amps - A No. FansFan power draw - kW

3Air ow - m /hrNo.poles - fan

1752620.9110004

50°C Supply60°C Supply70°C Supply

70.3867.0064.80

12.8 23.1

6.95.4

Model – 80kW 50hz

10° C AmbientConditions

50°C Supply60°C Supply70°C Supply

20° C AmbientConditions

50°C Supply60°C Supply70°C Supply

69.867.6465.16

85.9480.2874.12

16.7

16.9

29.5

29.7

4.05

4.75

Heat output KW Power input KW

30° C AmbientConditions

Motor data

Compressor MCC - ACompressor - HPFan size – mmFan current draw – A/PhFan wiringNoise rating – dB

50.020.05002.7Star Y66

Locked rotor amps – ARated load amps - A No. FansFan power draw - kW

3Air ow - m /hrNo.poles - fan

21535.721.3142004

Water CircuitWater ttingsPressure drop across unit - dP

Refrigeration circuitRefrigerant charge per circuit – kgNo. refrigerant circuits

2” FBSP52

6.0

Minimum ow across unit- l/s

1

2.5

Oil charge- per circuit - kg 7.0

50°C Supply60°C Supply70°C Supply

96.5389.7886.03

17.1 29.9 5.25

Current draw A/ph COP

Current draw A/ph COP

Ambient operation range -5 < 45 degreeC

Ambient operation range -5 < 45 degreeC

Page 5: catalogue Thermex 2019 - Công ty CN SEILAR Việt Nam

Ambient operation range -5 < 45 degreeC

TECHNICAL DATA Designed, manufactured and engineered in Australia

Model – 90kW 50hz

10° C AmbientConditions

50°C Supply60°C Supply70°C Supply

20° C AmbientConditions

50°C Supply60°C Supply70°C Supply

87.7283.4383.25

106.299.2895.76

20.6

20.9

37.0

37.4

4.05

4.75

Heat output KW Power input KW

30° C AmbientConditions

Motor data

Compressor MCCCompressor - HPFan size – mmFan current draw – A/PhFan wiringNoise rating – dB

Water CircuitWater ttingsPressure drop across unit - dP

Refrigeration circuitRefrigerant charge per circuit – kg

69.0255002.7Star Y66

2” FBSP52

Minimum ow across unit- l/s 3.0

7.0 Oil charge- per circuit - kg 7.0

Locked rotor amps – ARated load amps - A No. FansFan power draw - kW

3Air ow - m /hrNo.poles - fan

27049.321.3142004

50°C Supply60°C Supply70°C Supply

119.475111.825107.88

21.3 37.9 5.25

Model – 110kW 50hz

10° C AmbientConditions

50°C Supply60°C Supply70°C Supply

20° C AmbientConditions

50°C Supply60°C Supply70°C Supply

103.95100.898.25

121.77112.53108.88

24.0

24.2

44.6

44.6

4.2

4.65

Heat output KW Power input KW

30° C AmbientConditions

Motor data

Compressor MCC - ACompressor - HPFan size – mmFan current draw – A/PhFan wiringNoise rating – dB

Water CircuitWater ttingsPressure drop across unit - dP

Refrigeration circuitRefrigerant charge per circuit – kg

32.0306302.4Star Y63

2” FBSP49

Minimum ow across unit- l/s 3.5

6.5 Oil charge- per circuit - kg 6.5

Locked rotor amps – ARated load amps - A No. FansFan power draw - kW

3Air ow - m /hrNo.poles - fan

17526.021.2160006

50°C Supply60°C Supply70°C Supply

139.59130.68126.72

24.2 44.8 5.4

Current draw A/ph COP

Current draw A/ph COP

Ambient operation range -5 < 45 degreeC

Page 6: catalogue Thermex 2019 - Công ty CN SEILAR Việt Nam

Ambient operation range -5 < 45 degreeC

TECHNICAL DATA Designed, manufactured and engineered in Australia

Model – 150kW

50hz

10° C Ambient

Conditions

50°C Supply

60°C Supply

70°C Supply

20° C Ambient

Conditions

50°C Supply

60°C Supply

70°C Supply

139.59

135.27

130.32

161.88

152.1

148.23

33.4

33.8

59.0

59.4

4.05

4.5

Heat output

KW

Power input

KW

30° C Ambient

Conditions

Motor data

Compressor MCC - A

Compressor - HP

Fan size – mm

Fan current draw – A/Ph

Fan wiring

Noise rating – dB

Water Circuit

Water ttings

Pressure drop across unit - dP

Refrigeration circuit

Refrigerant charge per circuit – kg

50.0

40

500

5.4

Star Y

69

2” FBSP

52

Minimum ow across unit- l/s

6.0 Oil charge- per circuit - kg 7.0

Locked rotor amps – A

Rated load amps - A

No. Fans

Fan power draw - kW

3Air ow - m /hr

No.poles - fan

215

35.7

4

2.6

28400

4

5.0

50°C Supply

60°C Supply

70°C Supply

193.05

179.55

181.35

34.2 59.8 5.25

Current draw

A/ph

COP

Page 7: catalogue Thermex 2019 - Công ty CN SEILAR Việt Nam

DIMENSIONS

TECHNICAL DATADesigned, manufactured and engineered in Australia

All operational heating capacity, power consumption and current draw data shown above is based on

the heat pump operating at the limit of its design and is intended to be an indication only.

THERMEX’s product range is subject to change without notice

Each unit will be individually designed to customer requirements and a detailed product specication will

be supplied at time of order including installation instructions and dimensions. The power consumed by

the unit and the current it will draw vary depending on how the unit is constructed. The units performance

may also vary slightly from the gures above again based on customer requirements.

Model

THW30AV

THW50AV

THW60AV

THW80AV

580

680

680

810

THW90AV

THW110AV

THW150AV

810

860

2000

1060

1500

1500

1900

1900

1960

2000

A B C D E Shipping weight No. per container

1140

1250

1250

1400

1400

1675

1400

150

204

204

225

225

225

225

300

354

354

375

375

375

375

160

170

180

250

280

350

620

20

8

8

7

7

7

3