Catalogue June 2010 - iLECSYS › images › pdf › altivar61.pdf · 16, 17 and 0 Please refer to...

120
Variable speed drives Altivar 61 and Altivar 61 Plus for asynchronous motors from 0.75 to 2400 kW Catalogue June 2010

Transcript of Catalogue June 2010 - iLECSYS › images › pdf › altivar61.pdf · 16, 17 and 0 Please refer to...

  • Variable speed drives Altivar 61 and Altivar 61 Plusfor asynchronous motors from 0.75 to 2400 kW

    Catalogue

    June 2010

  • All technical information about products listed in this catalogue are now available on:www.schneider-electric.comBrowse the “product data sheet” to check out :

    characteristics,dimensions,curves, ...and also the links to the user guides and the CAD files.

    pppp

    1 From the home page, type the model number* into the “Search” box.

    2 Under ”All” tab, click the model number that interests you.

    * type the model number without any blank, replace “p” by “*”

  • U

    C

    t1

    G

    Rt'1t2 t'2

    U

    C

    t1

    G

    Rt'1t2 t'2

    89,5

    80

    8222,5

    78

    3 The product data sheet displays.

    You can get this information in one single pdf file.

    Discover this productCharacteriticsFunctionsConnectionDimensionsDownload & Documents

    Other productsHelp me to choose

    AccessoriesPlugSockets

    ppppp

    p

    pp

    Example : Zelio Time data sheet

    Example : Zelio Time data sheet

    Example : Zelio Time data sheet

  • ��

  • ��

    Contents Variable speed drives Altivar 61 and Altivar 61 Plus

    Selection guide: IP 20 variable speed drives . . . . . . . . . . . . . . . . . . . . . . . page 4

    Selection guide: IP 54 or IP 55 variable speed drives . . . . . . . . . . . . . . . . . page 6

    Selection guide: Altivar 61 Plus variable speed drives . . . . . . . . . . . . . . . page 8

    Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10

    Variable speed drives

    IP �0, supply voltage �00…�40 V or �80…480 V . . . . . . . . . . . . . . . . . page 16

    IP �0, supply voltage 500…690 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 20

    IP 54, supply voltage �80…480 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18

    IP 54, with Vario switch disconnector . . . . . . . . . . . . . . . . . . . . . . . . . . . page 19

    Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21

    Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23

    Dialogue and configuration tools

    Remote graphic display terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 31

    Configuration tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 33

    SoMove setup software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 34

    Combinations of variable speed drives and options . . . . . . . . . . . . . . page 38

    Options

    Encoder interface cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 48

    I/O extension cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 49

    Multi-pump cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 50

    “Controller inside” programmable cardprogrammable card . . . . . . . . . . . . . . . . . . . . . . . . . page 52

    Communication buses and networks . . . . . . . . . . . . . . . . . . . . . . . . . . . page 56

    Active Front End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60

    Resistance braking units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 64

    Braking units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 65

    Réduction of current harmonics:

    DC chokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 68

    line chokes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 70

    passive filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 73

    Additional EMC input filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 76

    Output filters:

    motor chokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 79

    sinus filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 82

    Motor starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 84

    Pre-equipped IP 54 floor-standing enclosure kit . . . . . . . . . . . . . . . . . . . . page 96

    Altivar 61 Plus

    “Ready to use” IP 54 floor-standing enclosurefloor-standing enclosureenclosure . . . . . . . . . . . . . . . . . . . . page 98

    IP 23 or IP 54 floor-standing enclosure �ith separate air flo�sfloor-standing enclosure �ith separate air flo�s . . . . . . page 100

    IP 23 or IP 54 floor-standing enclosure compact versionfloor-standing enclosure compact versioncompact version . . . . . . . . . . . page 105

    Product reference index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 116

    b

    b

    v

    v

    v

    v

    v

    v

    b

    v

    v

    v

    b

    b

    v

    v

    v

    v

    v

    v

    v

    v

    v

    -

    -

    -

    v

    v

    -

    -

    b

    b

    b

    v

    v

    v

    b

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    44

    Selection guide IP 20 variable speed drives for asynchronous and synchronous motors

    Type of machine Simple machines Pumps and fans(building (HVAC)) (1)

    Power range for 50…60 Hz (kW) line supply 0.18…4 0.18…15 0.75…75

    Single-phase 100…1�0 V (kW) 0.18…0.75 – –Single-phase �00…�40 V (kW) 0.18…�.� 0.18…�.� –Three-phase �00…��0 V (kW) – – –Three-phase �00…�40 V (kW) 0.18…4 0.18…15 0.75…�0Three-phase �80…480 V (kW) – – 0.75…75Three-phase �80…500 V (kW) – 0.�7…15 –Three-phase 500…600 V (kW) – – –Three-phase 5�5…600 V (kW) – 0.75…15 –Three-phase 500…690 V (kW) – – –

    Drive Output frequency 0.1…400 Hz 0.1…500 Hz 0.1…�00 Hz

    Type of control Asynchronous motor Standard (voltage/frequency)Performance (sensorless flu��sensorless flu�� vector control)Pump/fan (Kn� quadratic ratio)

    Standard (voltage/frequency)Performance (sensorless flu�� vector control)Energy saving ratio

    Sensorless flu�� vector controlVoltage/frequency ratio (� points)Energy saving ratio

    Synchronous motor –Transient overtorque 150…170% of the nominal

    motor torque170…�00% of the nominal motor torque

    1�0% of the nominal motor torque

    FunctionsNumber of functions 40 50 50Number of preset speeds 8 16 7Number of I/O

    Analog inputs 1 � �Logic inputs 4 6 �Analog outputs 1 1 1Logic outputs 1 – –Relay outputs 1 � �

    Communication Embedded Modbus Modbus and CANopen ModbusAs an option – CANopen Daisy Chain,

    DeviceNet, PROFIBUS DP, Modbus TCP, Fipio

    LonWorks, METASYS N�, APOGEE FLN, BACnet

    Cards (available as an option) –

    Dialogue tools IP 54 or IP 65 remote terminal IP 54 or IP 65 remote terminalIP 54 remote graphic display terminal

    IP 50 remote terminal

    Configuration tools SoMove setup softwareSimple Loader and Multi-Loader configuration tools

    PCSoft setup software for ATV �1

    Standards and certifications IEC/EN 61800-5-1, IEC/EN 61800-� (environments 1 and �, categories C1 to C�)e, UL, CSA, C-Tick, NOM, GOST EN 55011: Group 1, class A

    and class B with option card. e, UL, CSA, C-Tick, NOM

    References ATV 12 ATV 312 ATV 21

    Pages Please refer to the "Altivar 1� variable speed drives" catalogue

    Please refer to the "Altivar �1� variable speed drives" catalogue

    Please refer to the "Altivar �1 variable speed drives" catalogue

    (1) Heating Ventilation Air Conditioning

    Pumps and fans(industrial)

    Complex machines

    0.37…800 0.37…630

    – –0.�7…5.5 0.�7…5.5– –0.75…90 0.�7…750.75…6�0 0.75…500– –�.�…7.5 1.5…7.5– –�.�…800 1.5…6�0

    0.1…500 Hz for the entire range 0.1…599 Hz up to �7 kW at �00…�40 V a and �80…480 V a

    0.1…500 Hz for the entire range 0.1…599 Hz up to �7 kW at �00…�40 V a and �80…480 V a

    Sensorless flu�� vector controlVoltage/frequency ratio (� or 5 points) Energy saving ratio

    Flux vector control with or without sensorVoltage/frequency ratio (� or 5 points)ENA System

    Vector control without speed feedback Vector control with or without speed feedback1�0% of the nominal motor torque for 60 seconds ��0% of nominal motor torque for � seconds

    170% for 60 seconds

    > 100 > 1508 16�…4 �…46…�0 6…�01…� 1…�0…8 0…8�…4 �…4

    Modbus and CANopenModbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link,, LonWorks, METASYS N�, APOGEE FLN, BACnet

    Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link

    I/O extension cards, “Controller Inside” programmable card, multi-pump cards, encoder interface cards

    Interface cards for incremental, resolver, SinCos, SinCos Hiperface®, EnDat® or SSI encoders, I/O extension cards, Controller Inside programmable card

    IP 54 or IP 65 remote graphic display terminal

    SoMove setup softwareSimple Loader and Multi-Loader configuration tools

    IEC/EN 61800-5-1, IEC/EN 61800-� (environments 1 and �, C1 to C�), IEC/EN 61000-4-�/4-�/4-4/4-5/4-6/4-11 e, UL, CSA, DNV, C-Tick, NOM, GOST

    ATV 61 ATV 71

    16, 17 and �0 Please refer to the "Altivar 71 variable speed drives" catalogue

    More technical information on www.schneider-electric.com . . . please consult the end pages of this catalogue

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    55

    Type of machine Simple machines Pumps and fans(building (HVAC)) (1)

    Power range for 50…60 Hz (kW) line supply 0.18…4 0.18…15 0.75…75

    Single-phase 100…1�0 V (kW) 0.18…0.75 – –Single-phase �00…�40 V (kW) 0.18…�.� 0.18…�.� –Three-phase �00…��0 V (kW) – – –Three-phase �00…�40 V (kW) 0.18…4 0.18…15 0.75…�0Three-phase �80…480 V (kW) – – 0.75…75Three-phase �80…500 V (kW) – 0.�7…15 –Three-phase 500…600 V (kW) – – –Three-phase 5�5…600 V (kW) – 0.75…15 –Three-phase 500…690 V (kW) – – –

    Drive Output frequency 0.1…400 Hz 0.1…500 Hz 0.1…�00 Hz

    Type of control Asynchronous motor Standard (voltage/frequency)Performance (sensorless flu��sensorless flu�� vector control)Pump/fan (Kn� quadratic ratio)

    Standard (voltage/frequency)Performance (sensorless flu�� vector control)Energy saving ratio

    Sensorless flu�� vector controlVoltage/frequency ratio (� points)Energy saving ratio

    Synchronous motor –Transient overtorque 150…170% of the nominal

    motor torque170…�00% of the nominal motor torque

    1�0% of the nominal motor torque

    FunctionsNumber of functions 40 50 50Number of preset speeds 8 16 7Number of I/O

    Analog inputs 1 � �Logic inputs 4 6 �Analog outputs 1 1 1Logic outputs 1 – –Relay outputs 1 � �

    Communication Embedded Modbus Modbus and CANopen ModbusAs an option – CANopen Daisy Chain,

    DeviceNet, PROFIBUS DP, Modbus TCP, Fipio

    LonWorks, METASYS N�, APOGEE FLN, BACnet

    Cards (available as an option) –

    Dialogue tools IP 54 or IP 65 remote terminal IP 54 or IP 65 remote terminalIP 54 remote graphic display terminal

    IP 50 remote terminal

    Configuration tools SoMove setup softwareSimple Loader and Multi-Loader configuration tools

    PCSoft setup software for ATV �1

    Standards and certifications IEC/EN 61800-5-1, IEC/EN 61800-� (environments 1 and �, categories C1 to C�)e, UL, CSA, C-Tick, NOM, GOST EN 55011: Group 1, class A

    and class B with option card. e, UL, CSA, C-Tick, NOM

    References ATV 12 ATV 312 ATV 21

    Pages Please refer to the "Altivar 1� variable speed drives" catalogue

    Please refer to the "Altivar �1� variable speed drives" catalogue

    Please refer to the "Altivar �1 variable speed drives" catalogue

    (1) Heating Ventilation Air Conditioning

    Pumps and fans(industrial)

    Complex machines

    0.37…800 0.37…630

    – –0.�7…5.5 0.�7…5.5– –0.75…90 0.�7…750.75…6�0 0.75…500– –�.�…7.5 1.5…7.5– –�.�…800 1.5…6�0

    0.1…500 Hz for the entire range 0.1…599 Hz up to �7 kW at �00…�40 V a and �80…480 V a

    0.1…500 Hz for the entire range 0.1…599 Hz up to �7 kW at �00…�40 V a and �80…480 V a

    Sensorless flu�� vector controlVoltage/frequency ratio (� or 5 points) Energy saving ratio

    Flux vector control with or without sensorVoltage/frequency ratio (� or 5 points)ENA System

    Vector control without speed feedback Vector control with or without speed feedback1�0% of the nominal motor torque for 60 seconds ��0% of nominal motor torque for � seconds

    170% for 60 seconds

    > 100 > 1508 16�…4 �…46…�0 6…�01…� 1…�0…8 0…8�…4 �…4

    Modbus and CANopenModbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link,, LonWorks, METASYS N�, APOGEE FLN, BACnet

    Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link

    I/O extension cards, “Controller Inside” programmable card, multi-pump cards, encoder interface cards

    Interface cards for incremental, resolver, SinCos, SinCos Hiperface®, EnDat® or SSI encoders, I/O extension cards, Controller Inside programmable card

    IP 54 or IP 65 remote graphic display terminal

    SoMove setup softwareSimple Loader and Multi-Loader configuration tools

    IEC/EN 61800-5-1, IEC/EN 61800-� (environments 1 and �, C1 to C�), IEC/EN 61000-4-�/4-�/4-4/4-5/4-6/4-11 e, UL, CSA, DNV, C-Tick, NOM, GOST

    ATV 61 ATV 71

    16, 17 and �0 Please refer to the "Altivar 71 variable speed drives" catalogue

    More technical information on www.schneider-electric.com . . . please consult the end pages of this catalogue

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    66

    Selection guide IP 54 or IP 55 variable speed drives for asynchronous and synchronous motors

    Type of machine Simple machines Pumps and fans (building (HVAC)) (1)

    Pumps and fans (industrial)

    Complex machines

    Power range for 50…60 Hz (kW) line supply 0.18…15 0.75…75 0.75…90 0.75…75

    Single-phase �00…�40 V (kW) 0.18…�.� – –Three-phase �80…480 V (kW) – 0.75…75 0.75…90 0.75…75Three-phase �80…500 V (kW) 0.�7…15 – –

    Degree of protection IP 55 IP 54 IP 54Variants Enclosure user-definable up to 4 kW:

    Vario switch disconnector, LEDs, selector switch, potentiometer

    Enclosure user-definable up to 5.5 kW:  Vario switch disconnector

    – Equipped with a Vario switch disconnector

    – Equipped with a Vario switch disconnector

    Drive Output frequency 0.1…500 Hz 0.1…�00 Hz 0.1…599 Hz from 0.75 to 45 kW0.1…500 Hz from 55…90 kW55…90 kW

    0.1…599 Hz from 0.75 to �7 kW0.1…500 Hz from 45 to 75 kW

    Type of control Asynchronous motor Sensorless flu�� vector controlVoltage/frequency ratio

    Sensorless flu�� vector controlVoltage/frequency ratio (� points)Energy saving ratio

    Sensorless flu�� vector controlVoltage/frequency ratio (� or 5 points) Energy saving ratio

    Sensorless flu�� vector controlVoltage/frequency ratio (� or 5 points) ENA System

    Synchronous motor – – Vector control without speed feedback Vector control with or without speed feedbackTransient overtorque 170…�00% of the nominal motor torque 1�0% of the nominal motor torque for

    60 seconds110% of the nominal motor torque for 60 seconds ��0% of the nominal motor torque for � seconds

    170% for 60 seconds

    FunctionsNumber of functions 50 50 >100 >150Number of preset speeds 16 7 8 16Number of I/O Analog inputs � � �…4 �…4

    Logic inputs 6 � 6…�0 6…�0Analog outputs 1 1 1…� 1…�Logic outputs – – 0…8 0…8Relay outputs � � �…4 �…4

    Communication Embedded Modbus and CANopen Modbus Modbus and CANopenAs an option Modbus TCP, Fipio, PROFIBUS DP,

    DeviceNetLonWorks, METASYS N�, APOGEE FLN, BACnet

    Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link,, LonWorks, METASYS N�, APOGEE FLN, BACnet

    Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link

    Cards (available as an option) – – I/O extension cards, “Controller Inside” programmable card, multi-pump cards, encoder interface cards

    Interface cards for incremental, resolver, SinCos, SinCos Hiperface®, EnDat® or SSI encoders, I/O extension cards, Controller Inside programmable card

    Dialogue tools IP 65 remote terminal IP 50 remote terminal IP 54 or IP 65 remote graphic display terminalConfiguration tools SoMove setup software

    Simple Loader configuration toolPCSoft setup software for Altivar �1 drive SoMove setup software

    Simple Loader and Multi-Loader configuration tools

    Standards and certifications IEC 61800-5-1, IEC 61800-� (environments 1 and �, categories C1 to C�) IEC 61800-5-1, IEC 61800-� (environments 1 and �, categories C1 to C�), IEC 61000-4-�/4-�/4-4/4-5/4-6/4-11 e, UL, CSA, C-Tick, GOST e, UL, CSA, C-Tick, NOM e, UL, CSA, DNV, C-Tick, NOM, GOST

    References ATV 31C ATV 21W ATV 61W ATV 61E5 ATV 71W ATV 71E5

    Pages Please refer to the "Altivar �1C variable speed drives" catalogue

    Please refer to the "Altivar �1 variable speed drives" catalogue

    18 19 Please refer to the "Altivar 71 variable speed drives" catalogue

    (1) Heating, Ventilation and Air Conditioning

    More technical information on www.schneider-electric.com . . . please consult the end pages of this catalogue

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    77

    Type of machine Simple machines Pumps and fans (building (HVAC)) (1)

    Pumps and fans (industrial)

    Complex machines

    Power range for 50…60 Hz (kW) line supply 0.18…15 0.75…75 0.75…90 0.75…75

    Single-phase �00…�40 V (kW) 0.18…�.� – –Three-phase �80…480 V (kW) – 0.75…75 0.75…90 0.75…75Three-phase �80…500 V (kW) 0.�7…15 – –

    Degree of protection IP 55 IP 54 IP 54Variants Enclosure user-definable up to 4 kW:

    Vario switch disconnector, LEDs, selector switch, potentiometer

    Enclosure user-definable up to 5.5 kW:  Vario switch disconnector

    – Equipped with a Vario switch disconnector

    – Equipped with a Vario switch disconnector

    Drive Output frequency 0.1…500 Hz 0.1…�00 Hz 0.1…599 Hz from 0.75 to 45 kW0.1…500 Hz from 55…90 kW55…90 kW

    0.1…599 Hz from 0.75 to �7 kW0.1…500 Hz from 45 to 75 kW

    Type of control Asynchronous motor Sensorless flu�� vector controlVoltage/frequency ratio

    Sensorless flu�� vector controlVoltage/frequency ratio (� points)Energy saving ratio

    Sensorless flu�� vector controlVoltage/frequency ratio (� or 5 points) Energy saving ratio

    Sensorless flu�� vector controlVoltage/frequency ratio (� or 5 points) ENA System

    Synchronous motor – – Vector control without speed feedback Vector control with or without speed feedbackTransient overtorque 170…�00% of the nominal motor torque 1�0% of the nominal motor torque for

    60 seconds110% of the nominal motor torque for 60 seconds ��0% of the nominal motor torque for � seconds

    170% for 60 seconds

    FunctionsNumber of functions 50 50 >100 >150Number of preset speeds 16 7 8 16Number of I/O Analog inputs � � �…4 �…4

    Logic inputs 6 � 6…�0 6…�0Analog outputs 1 1 1…� 1…�Logic outputs – – 0…8 0…8Relay outputs � � �…4 �…4

    Communication Embedded Modbus and CANopen Modbus Modbus and CANopenAs an option Modbus TCP, Fipio, PROFIBUS DP,

    DeviceNetLonWorks, METASYS N�, APOGEE FLN, BACnet

    Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link,, LonWorks, METASYS N�, APOGEE FLN, BACnet

    Modbus TCP Daisy Chain, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link

    Cards (available as an option) – – I/O extension cards, “Controller Inside” programmable card, multi-pump cards, encoder interface cards

    Interface cards for incremental, resolver, SinCos, SinCos Hiperface®, EnDat® or SSI encoders, I/O extension cards, Controller Inside programmable card

    Dialogue tools IP 65 remote terminal IP 50 remote terminal IP 54 or IP 65 remote graphic display terminalConfiguration tools SoMove setup software

    Simple Loader configuration toolPCSoft setup software for Altivar �1 drive SoMove setup software

    Simple Loader and Multi-Loader configuration tools

    Standards and certifications IEC 61800-5-1, IEC 61800-� (environments 1 and �, categories C1 to C�) IEC 61800-5-1, IEC 61800-� (environments 1 and �, categories C1 to C�), IEC 61000-4-�/4-�/4-4/4-5/4-6/4-11 e, UL, CSA, C-Tick, GOST e, UL, CSA, C-Tick, NOM e, UL, CSA, DNV, C-Tick, NOM, GOST

    References ATV 31C ATV 21W ATV 61W ATV 61E5 ATV 71W ATV 71E5

    Pages Please refer to the "Altivar �1C variable speed drives" catalogue

    Please refer to the "Altivar �1 variable speed drives" catalogue

    18 19 Please refer to the "Altivar 71 variable speed drives" catalogue

    (1) Heating, Ventilation and Air Conditioning

    More technical information on www.schneider-electric.com . . . please consult the end pages of this catalogue

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    88

    Type of machine Pumps and fans (industrial)

    Complex machines (industrial and infrastructure)

    Power range for 50…60 Hz (kW) line supply 90…630 90…800 630…2400 90…500 90…630 500…2000

    Three-phase �80…415 V 90...6�0 90...6�0 6�0...1400 90…500 90…500 500…1�00Three-phase 500 V – 90...6�0 6�0...1800 – 90…500 500…1500Three-phase 690 V – 110...800 800...�400 – 110…6�0 6�0…�000

    Main characteristics With enhanced protection With enhanced protection and integrated cooling circuit

    With enhanced protection With enhanced protection and integrated cooling circuit

    Variants Ready to use Standard offerModular with integrated optionsUser-definable on request

    Ready to use Standard offerModular with integrated optionsUser-definable on request

    Drive Output frequency 0.1...500 Hz 0.1…500 Hz

    Type of control Asynchronous motor

    Sensorless flu�� vector control Voltage/frequency ratio � or 5 pointsEnergy saving ratio

    Flux vector control with or without sensor Voltage/frequency ratio (� or 5 points)ENA System

    Synchronous motor Flux vector control without speed feedback Vector control with or without speed feedback

    Transient overtorque 1�0% of the nominal motor torque for 60 seconds ��0% of the nominal motor torque for � seconds170% of the nominal motor torque for 60 seconds

    Communication Embedded Modbus and CANopen Modbus and CANopen

    As an option Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-LinkLonWorks, METASYS N�, APOGEE FLN, BACnet

    Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link

    Cards (available as an option) “Controller Inside” programmable cardMulti-pump cards

    “Controller Inside” programmable card

    Degree of protection IP 54 �ith separate air flo�s, ATV 61ES5

    IP �� compact version, ATV 61EXC2IP 54 compact version, ATV 61EXC5IP 54 �ith separate air flo�s, ATV 61EXS5

    With integrated air-cooled circuit:IP ��: ATV 61EXA2IP 54: ATV 61EXA5With external water-cooled system: IP 55, on request

    IP 54 �ith separate air flo�s, ATV 71ES5 IP �� compact version, ATV 71EXC2IP 54 compact version, ATV 71EXC5IP 54 �ith separate air flo�s, ATV 71EXS5

    IP ��, with integrated air-cooled circuit, ATV 71EXA2IP 54, with integrated air-cooled circuit, ATV 71EXA5IP 55, with external water-cooled system (on request)

    References ATV 61 Plus ATV 71 PlusPages 99 106 and 10� 10� Please refer to the "Altivar 71 variable speed drives" catalogue

    Selection guide Variable speed drives Altivar 61 Plus and Altivar 71 PlusIntegrated solutions

    More technical information on www.schneider-electric.com . . . please consult the end pages of this catalogue

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    99

    Type of machine Pumps and fans (industrial)

    Complex machines (industrial and infrastructure)

    Power range for 50…60 Hz (kW) line supply 90…630 90…800 630…2400 90…500 90…630 500…2000

    Three-phase �80…415 V 90...6�0 90...6�0 6�0...1400 90…500 90…500 500…1�00Three-phase 500 V – 90...6�0 6�0...1800 – 90…500 500…1500Three-phase 690 V – 110...800 800...�400 – 110…6�0 6�0…�000

    Main characteristics With enhanced protection With enhanced protection and integrated cooling circuit

    With enhanced protection With enhanced protection and integrated cooling circuit

    Variants Ready to use Standard offerModular with integrated optionsUser-definable on request

    Ready to use Standard offerModular with integrated optionsUser-definable on request

    Drive Output frequency 0.1...500 Hz 0.1…500 Hz

    Type of control Asynchronous motor

    Sensorless flu�� vector control Voltage/frequency ratio � or 5 pointsEnergy saving ratio

    Flux vector control with or without sensor Voltage/frequency ratio (� or 5 points)ENA System

    Synchronous motor Flux vector control without speed feedback Vector control with or without speed feedback

    Transient overtorque 1�0% of the nominal motor torque for 60 seconds ��0% of the nominal motor torque for � seconds170% of the nominal motor torque for 60 seconds

    Communication Embedded Modbus and CANopen Modbus and CANopen

    As an option Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-LinkLonWorks, METASYS N�, APOGEE FLN, BACnet

    Modbus TCP, Modbus/Uni-Telway, EtherNet/IP, DeviceNet, PROFIBUS DP V0 and V1, InterBus, CC-Link

    Cards (available as an option) “Controller Inside” programmable cardMulti-pump cards

    “Controller Inside” programmable card

    Degree of protection IP 54 �ith separate air flo�s, ATV 61ES5

    IP �� compact version, ATV 61EXC2IP 54 compact version, ATV 61EXC5IP 54 �ith separate air flo�s, ATV 61EXS5

    With integrated air-cooled circuit:IP ��: ATV 61EXA2IP 54: ATV 61EXA5With external water-cooled system: IP 55, on request

    IP 54 �ith separate air flo�s, ATV 71ES5 IP �� compact version, ATV 71EXC2IP 54 compact version, ATV 71EXC5IP 54 �ith separate air flo�s, ATV 71EXS5

    IP ��, with integrated air-cooled circuit, ATV 71EXA2IP 54, with integrated air-cooled circuit, ATV 71EXA5IP 55, with external water-cooled system (on request)

    References ATV 61 Plus ATV 71 PlusPages 99 106 and 10� 10� Please refer to the "Altivar 71 variable speed drives" catalogue

    More technical information on www.schneider-electric.com . . . please consult the end pages of this catalogue

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    1010

    PresentationThe Altivar 61 drive is a frequency inverter for 0.75 kW to �400 kW three-phase asynchronous motors.

    It has been designed for the most common fluid management applications  in industrial and commercial buildings and infrastructures.

    The Altivar 61 can increase the performance of equipment and reduce operating costs in buildings by optimizing energy consumption whilst improving user comfort.

    Eco friendlyIt is designed to be eco friendly:

    Eco-energy with a reduction in energy consumption of 70% for ventilation applications and 50% for pumping applications

    Reduction of fluid losses in distribution net�orksUse of 80% recyclable materials: the Altivar 61 drive conforms to environmentalthe Altivar 61 drive conforms to environmental drive conforms to environmental

    standard ISO 14040 �hich defines a critical analysis of the product's impact on the environment. An environmental report is available for the Altivar 61 drive on our website at "www.schneider-electric.com".

    b

    bb

    Compliance with international standards and certificationsThe Altivar 61 has been developed to meet the requirements of directives regarding the protection of the environment (RoHS, REACH, WEEE) as well as those of European Directives to obtain the e mark.

    The entire range is UL, CSA, DNV, C-Tick, NOM, GOST certified and conforms to certified and conforms tocertified and conforms to international standards relating to electrical industrial control equipment IEC/EN 61800-� and IEC/EN 61800-5-1.

    The need for electromagnetic compatibility was taken into account at the outset of designing the drive. The entire range conforms to international standardThe entire range conforms to international standard IEC/EN 61800-�.The Altivar 61 drive complies with the requirements of safety standards for applications in explosive atmospheres (ATEX). Please refer to the ATEX manual,Please refer to the ATEX manual, available on our website "www.schneider-electric.com".

    An extensive rangeThe Altivar 61 range offers numerous variants to meet the requirements of applications in a �ide variety of fields and in very harsh environments. With these variants, the Altivar 61 range offers ready-to-use or modular solutions to adapt perfectly to your needs.

    Its numerous and comprehensive options enable it to be adapted and incorporated into electrical installations, sophisticated control systems, infrastructures and building management systems.

    A specific option, the Active Front End, enables the Altivar 61 to be used in installations where particularly low harmonic levels are required. It also allows the Altivar 61 drive to operate on unstable power supplies.

    A wide range of applicationsThe Altivar 61 drive incorporates advanced functions for optimum efficiency in the majority of applications in the industrial or commercial buildings sector:b Ventilationb Air conditioningb Air purification, smoke e��tractionb Fluid managementb Pumping and booster stationsb Irrigation stationsb Off-shore drilling rigsb etc.

    Presentation Variable speed drivesAltivar 61

    Air purification application

    PF1

    0897

    1

    Air treatment application

    PF0

    95�0

    8

    Variable speed drives:page 16

    Variants:page �1

    Accessories:page ��

    Options: page 48

    Drive-option combinations:page �8

    PF0

    95�0

    9

    Water treatment application

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    1111

    Advanced functionsThe Altivar 61 drive meets the most stringent requirements due to its numerous integrated application functions, while ensuring the reliability of equipment with its protection and safety functions.

    Functions designed specifically for pump and fan applicationsb Energy saving ratio, � or 5 point quadratic ratio b Automatic catching of a spinning load with speed detectionb Adaptation of current limiting according to speedb Noise and resonance suppression due to the possibility of adjusting the switching frequency during operation, up to 16 kHz depending on the rating, and the possibility of making frequency skips.b Preset speeds b Integrated PID regulator with preset PID references and automatic/manual ("Auto/Man.") modeb Electricity and service hours meterb Fluid absence detection, zero flo� and limited flo� detectionb Sleep function, wake-up functionb Customer settings with display of physical measurements: bar, I/s, °C, etc.

    Protection functionsb Motor and drive thermal protection, PTC thermal probe managementb Protection against overloads and overcurrents in continuous operationb Machine mechanical protection via skip frequency function, output phase rotationb Protection of the installation by means of underload, overload and zero flo� detectionb Protection via management of multiple faults and configurable alarms

    Safety functionsb Machine safety via the integrated Power Removal functionThis function stops the motor and prevents unintentional restarting of the motor; it complies with machine safety standard EN 954-1, category � and the standard for functional safety IEC/EN 61508, SIL� capability (safety control-signalling applied to processes and systems).This safety function means that the drive can be installed as part of the safety system for an Electrical/Electronic/Programmable Electronic control system relating to the safety of a machine or industrial process. b Installation safety is assured by means of the forced operation function with configurable fault inhibiting, direction of operation and references.

    An advanced offer to adapt to your applications The Altivar 61 and Altivar 61 Plus offers cover motor power ratings from 0.75 kW to �400 kW with several types of power supply:

    Three-phase power supply Motor power Reference

    200...240 V 0.75 kW…90 kW ATV 61HpppM3ATV 61HpppM3X

    380...415 V 90 kW…6�0 kW ATV 61ES5pppN4ATV 61EXS5pppN4ATV 61EXCppppN4

    6�0 kW…1400 kW ATV 61EXAppppN4380…480 V 0.75 kW…6�0 kW ATV 61HpppN4

    0.75 kW…90 kW ATV 61WpppN4 ATV 61WpppN4C

    500 V 90 kW…6�0 kW ATV 61EXS5pppNATV 61EXCppppN

    6�0 kW…1800 kW ATV 61EXAppppN500…600 V 1.5 kW…15 kW ATV 61HpppS6X500…690 V �.� kW…800 kW ATV 61HpppY690 V 110 kW…800 kW ATV 61EXCppppY

    ATV 61EXS5pppY800 kW…�400 kW ATV 61EXAppppY

    Altivar 61 drives with �00…�40 V three-phase supply voltage can also be used with motor power ratings from 0.�7 kW to 5.5 kW single-phase, if the motor is derated.

    Presentation (continued) Variable speed drivesAltivar 61

    ATV 61EXS5ppppp

    PF0

    95�0

    5P

    F095

    495

    ATV 61W075N4, ATV 61W075N4C

    ATV 61HC31N4, ATV 61HD22M3X, ATV 61HU22N4

    Variable speed drives:page 16

    Variants:page �1

    Accessories:page ��

    Options: page 48

    Drive-option combinations:page �8

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    1�1�

    An advanced offer to adapt to your applications (continued) Flexibility in control systems and building management systems

    The Altivar 61 drive 1 has numerous logic and analog inputs and outputs that can be configured to adapt better to applications. Its functions can be extended by using I/O extension cards 2 (see page 49).

    It integrates the Modbus and CANopen protocols to enhance the performance of your control systems. It is open to other control system architectures for industry and integrates easily into building management systems (HVAC) using communication option cards 2 (see page 57). All communication protocols for use in industry (Modbus TCP, Ethernet/IP, Modbus /Modbus TCP, Ethernet/IP, Modbus /Modbus /Uni-Telway, PROFIBUS DP V0 or V1, DeviceNet, InterBus and CC-Link) or in building) or in building management (LonWorks, METASYS N�, APOGEE FLN, BACnet) are available.

    It can be open to a distributed architecture by using a Controller Inside programmable card 2 �hich allo�s the drive to be adapted to specific applications, quickly and in an open-ended manner, by decentralizing the control system functions (programming in IEC 611�1-� compliant languages) (see pages 5� to 55).

    It can ensure the management of several pumps by using multi-pump cards 2, (see pages 50 and 51).

    The Controller Inside and multi-pump cards have their own I/O and can manage the drive's I/O as �ell as those of the I/O e��tension cards. They can also use drive parameters such as speed, current, torque, etc.

    The Altivar 61 drive can also take an encoder interface card to increase the safety of the application (see page 48).

    Note: The Altivar 61 can accommodate a maximum of two option cards simultaneously; please refer to the summary table of possible combinations to find out which options are available for each drive (see pages 38 to 47) .

    Electromagnetic compatibility (EMC)The need for electromagnetic compatibility was taken into account at the outset of designing the drive.The incorporation of EMC filters in ATV 61HpppM3 and ATV 61ppppN4 drives and compliance with EMC requirements simplify installation and provide a very economical means of ensuring that devices meet the criteria to receive the e mark.ATV 61WpppN4C drives have integrated EMC filters, �hich make them compliant with the requirements of EN 55011 (class B group 1) and IEC/EN 61800-� (category C1) standards.

    ATV 61HpppM3X drives have been designed �ithout an EMC filter. Filters are available as an option and can be installed by the customer to reduce the level of emissions (see page 76).

    A wide range of options A large number of external options can be combined with the Altivar 61:b Braking units and resistors (see pages 64 to 67)b DC chokes, line chokes and passive filters (see pages 68 to 75) and the Active Front End option for the reduction of current harmonics (see pages 60 to 6�)b Additional EMC input filters (see pages 76 and 77)b Motor chokes and sinus filters for long cable runs or to remove the need for shielding (see pages 78 to 8�)

    Presentation (continued) Variable speed drivesAltivar 61

    Variable speed drives:page 16

    Variants:page �1

    Accessories:page ��

    Options: page 48

    Drive-option combinations:page �8

    21

    25�7

    174

    Extended functions using option cards

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    1�1�

    Solutions for all environmentsThe offer includes numerous variants which make it possible to further broaden the Altivar 61 drive's range of applications.

    Reinforced version variantThis reinforced version variant enables the Altivar 61 drive to be used for applications in difficult ambient pollution conditions (see page 21).

    Variant with Vario switch disconnectorAltivar 61 IP 54 drives can be supplied equipped with a Vario switch disconnector. This ready-assembled offer, ATV 61E5pppN4, is specially designed for applications that require an accessible drive as close as possible to the motor (such as in fluid, waste water and air treatment applications). It covers motor power ratings from 0.75 kW to 90 kW, with a three-phase supply voltage of from �80 to 480 V (see page 19).

    Variant for industrial environments and infrastructuresTo facilitate set-up in industrial environments and infrastructure contexts (tunnels, subways, smoke extraction and pumping, etc.), an enclosed drive solution is offered, available with a wide range of options.

    Altivar 61 Plus drive in IP 23 or IP 54 ready-assembled, compact enclosureThis enclosed drive solution provides IP �� or IP 54 protection (ATV 61EXCppppp). It is supplied ready-assembled and ready to connect.One common air circuit provides enclosure ventilation. The offer covers a range of drives from 90 kW to 800 kW (see page 106).

    In addition to a standard version, a modular version is available with a choice of options to suit the requirements of your installation.

    Variants for harsh and highly polluted environmentsThese variants offer enclosed drive solutions with cooling systems specially designed to allo� the Altivar 61 drive to operate in difficult environmental conditions.

    Pre-equipped IP 54 kitThis straightforward and cost-effective solution, which is available by quoting a single reference, provides you with all the mechanical components you need to create an IP 54 certified floor-standing enclosure (VW3 A9 541…VW3 A9 551) (see page 96). The overall storage dimensions are reduced to a minimum to allow assembly in e��tremely confined spaces.The cooling systems enable the equipment to be installed in a variety of difficult environments (1 or � air circuits, depending on the model).

    The pre-equipped kit is available for IP �0 Altivar 61 drives from 110 kW to 6�0 kW with a three-phase supply voltage �80…480 V.

    Altivar 61 Plus drive in "Ready to use" IP 54 floor-standing enclosure This enclosed drive solution provides IP 54 protection (ATV 61ES5pppN4).It is supplied ready-assembled and ready to connect. Optimum enclosure ventilation is ensured by two separate cooling circuits.The offer covers a range of drives from 90 kW to 6�0 kW (see page 98).

    Altivar 61 Plus drive in IP 23 or IP 54 floor-standing enclosure with separate air flowsThese floor-standing enclosures are designed to operate in harsh and highly polluted environments, by using two separate cooling circuits, one for the control section and one for the power section, to optimise enclosure ventilation.Depending on the model, they provide IP 54 protection (ATV 61EXS5pppp) and IP �� or IP 54 protection (ATV 61EXAppppp).The offer covers a range of drives from 90 kW to 6�0 kW (ATV 61EXS5pppp) and from 6�0 kW to �400 kW (ATV 61EXAppppp).

    It includes a standard version, a modular version via the addition of numerous options and a fully customizable version to suit your requirements.

    Variant for medium voltage motorsThis variant enables the Altivar 61 drive to be used for applications involving medium voltage motors (see page ��).

    Presentation (continued) Variable speed drivesAltivar 61

    PF0

    95�1

    0

    Altivar 61 equipped with a Vario switch disconnector

    Altivar 61 Plus drive in IP 23 or IP 54 floor-standing enclosure

    PF0

    95�0

    7P

    F107

    559

    Pre-equipped IP 54 kit

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    1414

    Mounting options The Altivar 61 drive can be mounted in a variety of ways to adapt to the various needs of an installation.

    Mounting outside enclosure The Altivar 61 drive can be mounted directly on a wall without having to be installed inside an enclosure. UL Type 1 conformity can be achieved by using kit VW3 A9 2pp, or IP �1 or IP �1 conformity with kit VW3 A9 1pp (see pages �� and �4).

    Flush-mounting in a dust-proof and damp-proof enclosureThe Altivar 61 drive has been designed to reduce the size of enclosures (floor-standing, wall-mounted, etc).Flush-mounting kit VW3 A9 5pp makes it possible to mount the power section outside the enclosure and limit the temperature rise inside the enclosure (see page �5).This variant also allows side-by-side mounting, if operating conditions require it.

    Dialogue and configuration tools Remote graphic display terminal

    The Altivar 61 drive 1 is supplied with a remote graphic display terminal 3.

    This terminal provides a user-friendly interface with fast and easy access, on-line help screens, te��t in the user's language (8 languages factory-installed, plus others available via flash memory). It is customizable for the customer or the machine. The advanced functions on the display unit allow easy access to the more complex configurations setup or maintenance functions.

    It can be located remotely on an enclosure door with IP 54 or IP 65 degree of protection on IP �0 drives, or built-in on IP 54 drives.(see page �1).

    SoMove Mobile Software SoMove Mobile software 2 is particularly suitable for maintenance operations. It can be used to edit the drive parameters from a mobile phone, save configurations, import them from a PC and export them to a PC via a Bluetooth® wireless connection.(see page ��).

    SoMove setup softwareSoMove setup software for PC 4 is used to configure, adjust and debug the Altivar 61 drive with the Oscilloscope function, and also for maintenance of this drive, as for all other Schneider Electric drives and starters.

    For presentation, description and references, see page �4.

    Simple Loader and Multi-Loader configuration toolsThe Simple Loader tool 6 enables the configuration from one po�ered-up drive to be duplicated on another powered-up drive.

    The Multi-Loader tool 5 enables configurations from a PC or drive to be copied and duplicated on another drive; Altivar 61 drives do not need to be powered up.(see page ��).

    Presentation (continued) Variable speed drivesAltivar 61

    5�71

    7�

    ATV 61HU75N4, flush-mounted

    Variable speed drives:page 16

    Variants:page �1

    Accessories:page ��

    Options: page 48

    Drive-option combinations:page �8

    4

    or

    Dialogue and configuration tools for Altivar 61 drive

    2

    5

    6or

    3

    1

  • 2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    2

    1

    3

    4

    5

    6

    7

    8

    9

    10

    1515

    Dialogue and configuration tools (continued) Quick programming toolsWith its macro-configurations and its Simply Start menu, the Altivar 61 drive gets applications up and running immediately.

    Macro-configurationThe Altivar 61 offers quick and easy programming using macro-configurations corresponding to different applications or uses: start-stop, pumping and ventilation, general use, connection to communication networks, PID regulator. Each of these configurations is still fully modifiable.

    Simply Start menu The Simply Start menu can be used to ensure that the application is working correctly, maximize motor performance and ensure motor protection.

    The architecture, the hierarchical parameter structure and the direct access functions all serve to make programming quick and easy, even for the more complex functions.

    Integrated functions for maintenance, monitoring and diagnostics

    The Altivar 61 has numerous built-in maintenance, monitoring and diagnostic functions.The option of powering the control part separately enables communication to be maintained (monitoring, diagnostics) even if there is no power supply to the power part.

    Example of functions:b Drive test functions with diagnostic screen on the remote graphic display terminalb I/O mapsb Communication maps for the different portsb Oscilloscope function that can be viewed using the SoMove setup software b Management of the drive installed base via microprocessors �ith flash memoryb Remote use of these functions by connecting the drive to a modem via the Modbus portb Identification of all the drive’s component parts as �ell as the soft�are versionsb Fault logs with display of the value of up to 16 variables on occurrence of a faultb Display terminal languages loaded in the flash memoryb Storage of a 5-line, �4-character message in the drive

    Documentation on the entire offerThe Altivar 61 range is also presented on a DVD-ROM which includes all the Schneider Electric documentation on variable speed drives and soft start/soft stop units.

    The DVD-ROM includes:Technical documentation (programming manuals, installation manuals, quick

    reference guides)Brochures Catalogues

    The content of the DVD ROM is also available on our website at "www.schneider-electric.com".

    b

    bb

    Description Reference Weightkg

    "Description of the Motion & Drives offer" DVD-ROM VW3 A8 200 0.100

    Presentation (continued) Variable speed drivesAltivar 61

    5�71

    66

    Simply Start menu

    Pomp. vent.Cde 2 fils

    50Hz IEC

    2.2kW

    400V

    :::

    :

    :

    +50.00HzTerm1.1 SIMPLY START

    Standard fréq. mot

    5.4A

    Macro-configuration

    Puissance nom. mot

    Tension nom. mot> QuickCode

    RUN

    Cde 2 fils/3 fils

    +50.00HzTermHISTORIQUE DEFAUTS

    Déf. Externe LI

    0.0A

    Surintensité

    Surtension réseau

    SoustensionQuickHelp

    SCF1

    Court-circuit mot.

    5�71

    65

    Fault log

    +50.00HzTermCOURT-CIRCUIT MOTEUR

    0.0A

    Effectuer un test de diagnostic

    Quick

    SCF1

    Vérifier les câbles de liaison et l'isolement du moteur.

    5�71

    64

    Troubleshooting screen

    Variable speed drives:page 16

    Variants:page �1

    Accessories:page ��

    Options: page 48

    Drive-option combinations:page �8

  • 16

    References1

    IP 20 drivesMotor Line supply Altivar 61Power indicated on rating plate (1)

    Line current (2)

    Apparent power

    Maximum prospective line Isc

    Maximum continuous current (1)

    Max. transient current for 60 s

    Reference Weight

    200 V 240 V 240 V 230 VkW HP A A kVA kA A A kgSingle-phase supply voltage: 200…240 V 50/60 Hz

    0.�7 0 .5 6.9 5.8 1.4 5 � �.6 ATV 61H075M3 �.0000.75 1 1� 9.9 �.4 5 4.8 5.7 ATV 61HU15M3 �.0001.5 2 18.� 15.7 �.7 5 8 9.6 ATV 61HU22M3 4.000�.� 3 �5.9 ��.1 5.� 5 11 1�.� ATV 61HU30M3 4.000� – �5.9 �� 5.� 5 1�.7 16.4 ATV 61HU40M3 (3) 4.0004 5 �4.9 �9.9 7 5 17.5 �1 ATV 61HU55M3 (3) 5.5005.5 7 .5 47.� 40.1 9.5 �� �7.5 �� ATV 61HU75M3 (3) 7.000

    Three-phase supply voltage: 200…240 V 50/60 Hz 0.75 1 6.1 5.� �.� 5 4.8 5.7 ATV 61H075M3 �.0001.5 2 11.� 9.6 4 5 8 9.6 ATV 61HU15M3 �.000�.� 3 15 1�.8 5.� 5 11 1�.� ATV 61HU22M3 4.000� – 19.� 16.4 6.8 5 1�.7 16.4 ATV 61HU30M3 4.0004 5 �5.8 ��.9 9.5 5 17.5 �1 ATV 61HU40M3 4.0005.5 7 .5 �5 �0.8 1�.8 �� �7.5 �� ATV 61HU55M3 5.5007.5 10 45 �9.4 16.4 �� �� �9.6 ATV 61HU75M3 7.00011 15 5�.� 45.8 19 �� 54 64.8 ATV 61HD11M3X (4) ��.00015 20 71.7 61.6 �5.6 �� 66 79.� ATV 61HD15M3X (4) ��.00018.5 25 77 69 �8.7 �� 75 90 ATV 61HD18M3X (4) �0.000�� 30 88 80 ��.� �� 88 105.6 ATV 61HD22M3X (4) �0.000�0 40 1�4 110 45.7 �� 1�0 144 ATV 61HD30M3X (4) �7.000�7 50 141 1�7 5�.8 �� 144 17�.8 ATV 61HD37M3X (4) �7.00045 60 167 147 61.1 �� 176 �11.� ATV 61HD45M3X (4) �7.00055 75 �00 17� 71.9 �5 ��1 �65.� ATV 61HD55M3X (4) 84.00075 100 �71 ��� 96.4 �5 �85 �4� ATV 61HD75M3X (4) 84.00090 125 ��6 �88 119.7 �5 �59 4�1 ATV 61HD90M3X (4) 106.000

    Dimensions (overall) Drives W x H x D

    mmATV 61H075M�, HU15M� 1�0 x ��0 x 175ATV 61HU��M�…HU40M� 155 x �60 x 187ATV 61HU55M� 175 x �95 x 187ATV 61HU75M� �10 x �95 x �1�ATV 61HD11M�X, HD15M�X ��0 x 400 x �1�ATV 61HD18M�X, HD��M�X �40 x 4�0 x ��6ATV 61HD�0M�X… HD45M�X ��0 x 550 x �66ATV 61HD55M�X, HD75M�X ��0 x 9�0 x �77ATV 61HD90M�X �60 x 10�� x �77(1) These values are given for a nominal switching frequency of 12 kHz up to ATV 61HD45M3X or 2.5 kHz for

    ATV 61HD55M3X…HD90M3X drives for use in continuous operation . The switching frequency is adjustable from 1…16 kHz up to ATV 61HD45M3X, from 2.5…12 kHz for ATV 61HD55M3X and from 2.5…8 kHz for ATV 61HD75M3X, HD90M3X. Above 2.5 or 12 kHz, depending on the rating, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise . For continuous operation above the nominal switching frequency, derate the nominal drive current, see derating curves on our website “www.schneider-electric.com”.

    (2) Typical value for the indicated motor power and for the maximum prospective line Isc . (3) A line choke must be used (see page 71).(4) Drive supplied without EMC filter. EMC filters are available as an option (see page 77).Note: Consult the summary tables of possible drive, option and accessory combinations (see pages 38, 39, 46 and 47) .

    Variable speed drives Altivar 61Supply voltage �00...�40 V 50/60 Hz

    PF1

    0757

    ATV 61H075M3

    PF1

    0757

    4

    ATV 61HU22M3Z

    PF1

    0758

    1

    ATV 61HD22M3X

    Variants:page �1

    Accessories:page ��

    Dialogue: page �1

    Drive-option combinations: page �8

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 17

    References (continued)1

    IP 20 drivesMotor Line supply Altivar 61Power indicated on rating plate (1)

    Line current (2)

    Apparent power

    Maximum prospective line Isc

    Maximum continuous current (1)

    Max. transient current for 60 s

    Reference Weight

    380 V 480 V 380 V 380 V (IEC)

    460 V(NEC)

    kW HP A A kVA kA A A kgThree-phase supply voltage: 380…480 V 50/60 Hz

    0.75 1 �.7 � �.4 5 �.� �.1 �.7 ATV 61H075N4 �.0001.5 2 5.8 5.� �.8 5 4.1 �.4 4.9 ATV 61HU15N4 �.000�.� 3 8.� 7.1 5.4 5 5.8 4.8 6.9 ATV 61HU22N4 �.000� – 10.7 9 7 5 7.8 6.� 9.� ATV 61HU30N4 4.0004 5 14.1 11.5 9.� 5 10.5 7.6 1�.6 ATV 61HU40N4 4.0005.5 7 .5 �0.� 17 1�.4 �� 14.� 11 17.1 ATV 61HU55N4 5.5007.5 10 �7 ��.� 17.8 �� 17.6 14 �1.1 ATV 61HU75N4 5.50011 15 �6.6 �0 �4.1 �� �7.7 �1 ��.� ATV 61HD11N4 7.00015 20 48 �9 �1.6 �� �� �7 �9.6 ATV 61HD15N4 ��.00018.5 25 45.5 �7.5 �9.9 �� 41 �4 49.� ATV 61HD18N4 ��.000�� 30 50 4� ��.9 �� 48 40 57.6 ATV 61HD22N4 �0.000�0 40 66 56 4�.4 �� 66 5� 79.� ATV 61HD30N4 �7.000�7 50 84 69 55.� �� 79 65 94.8 ATV 61HD37N4 �7.00045 60 104 85 68.5 �� 94 77 11�.8 ATV 61HD45N4 44.00055 75 1�0 101 79 �� 116 96 1�9.� ATV 61HD55N4 44.00075 100 167 1�7 109.9 �� 160 1�4 19� ATV 61HD75N4 44.00090 125 166 14� 109.� �5 179 179 �14.8 ATV 61HD90N4 84.000110 150 �0� 168 1�� �5 �15 �15 �58 ATV 61HC11N4 84.0001�� 200 ��9 ��4 157.� �5 �59 �59 �10.8 ATV 61HC13N4 106.000160 250 �89 �75 190.� 50 �14 �14 �76.8 ATV 61HC16N4 116.000�00 300 �57 ��1 ��5 50 4�7 4�7 51�.4 ATV 61HC22N4 16�.000��0 350 �96 �8� �60.6 50�50 400 444 4�5 �9�.� 50 481 481 577.� ATV 61HC25N4 �07.000�80 450 494 494 ��5.1 50 616 616 7�9.� ATV 61HC31N4 �07.000�15 500 555 544 �65.� 50�55 – 6�7 597 419.� 50 759 759 910.8 ATV 61HC40N4 ��0.000400 600 709 644 466.6 50500 700 876 760 576.6 50 941 941 11�9.� ATV 61HC50N4 ��0.000560 800 978 858 64�.6 50 1188 1188 14�5.6 ATV 61HC63N4 4�5.0006�0 900 1091 964 718 50Dimensions (overall) Drives W x H x D

    mmATV 61H075N4…HU��N4 1�0 x ��0 x 175ATV 61HU�0N4, HU40N4 155 x �60 x 187ATV 61HU55N4, HU75N4 175 x �95 x 187ATV 61HD11N4 �10 x �95 x �1�ATV 61HD15N4, HD18N4 ��0 x 400 x �1�ATV 61 HD��N4 �40 x 4�0 x ��6ATV 61HD�0N4, HD�7N4 �40 x 550 x �66ATV 61HD45N4… HD75N4 ��0 x 6�0 x �90ATV 61HD90N4, HC11N4 ��0 x 9�0 x �77ATV 61HC1�N4 �60 x 10�� x �77ATV 61HC16N4 �40 x 1190 x �77ATV 61HC��N4 440 x 1190 x �77ATV 61HC�5N4, HC�1N4 595 x 1190 x �77ATV 61HC40N4, HC50N4 890 x 1�90 x �77ATV 61HC6�N4 11�0 x 1�90 x �77

    (1) These values are given for a nominal switching frequency of 12 kHz up to ATV 61HD75N4, 4 kHz for ATV 61HD90N4 or 2.5 kHz for ATV 61HC11N4…HC63N4 drives for use in continuous operation. The switching frequency is adjustable from 1…16 kHz up to ATV 61HD75N4 and from 2…8 kHz for ATV 61HD90N4…ATV 61HC63N4 drives . Above 2.5, 4 or 12 kHz, depending on the rating, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise . For continuous operation above the nominal switching frequency, derate the nominal drive current, see derating curves on our website “www.schneider-electric.com”.

    (2) Typical value for the indicated motor power and for the maximum prospective line Isc . Note: Consult the summary tables of possible drive, option and accessory combinations (see pages 40, 41, 46 and 47) .

    Variable speed drives Altivar 61 Supply voltage �80...480 V 50/60 Hz

    PF1

    0748

    ATV 61HU22N4

    PF1

    0757

    5

    ATV 61HU40N4Z

    PF1

    0758

    6

    ATV 61HC31N4

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 18

    References (continued)1

    Motor Line supply Altivar 61Power indicated on rating plate (1)

    Line current (2)

    Apparent power

    Maximum prospective line Isc

    Maximum continuous current (1)

    Max. transient current for 60 s

    Reference Weight

    380 V 480 V 380 V 380 V(IEC)

    460 V (NEC)

    kW HP A A kVA kA A A kg

    IP 54 drives with integrated category C2 EMC filterThree-phase supply voltage: 380…480 V 50/60 Hz

    0.75 1 1.8 1.5 1.� 5 �.� �.1 �.5 ATV 61W075N4 1�.0001.5 2 �.5 � �.� 5 4.1 �.4 4.5 ATV 61WU15N4 1�.000�.� 3 5 4.1 �.� 5 5.1 4.8 5.6 ATV 61WU22N4 1�.000� – 6.7 5.6 4.4 5 7.� 6.� 7.9 ATV 61WU30N4 14.0004 5 8.8 7.4 5.8 5 9.1 7.6 10 ATV 61WU40N4 16.0005.5 7 .5 11.4 9.� 7.5 �� 1� 11 1�.� ATV 61WU55N4 16.0007.5 10 15.8 1�.� 10.4 �� 16 14 17.6 ATV 61WU75N4 ��.00011 15 �1.9 17.8 14.4 �� ��.5 �1 �4.7 ATV 61WD11N4 ��.00015 20 �0.5 �5.8 �0 �� �0.5 �7 ��.5 ATV 61WD15N4 �8.00018.5 25 �7.5 ��.� �4.7 �� �7 �4 40.7 ATV 61WD18N4 �6.000�� 30 4�.6 �6.6 �8.7 �� 4�.5 40 47.8 ATV 61WD22N4 �6.000�0 40 56.7 46.� �7.� �� 58.5 5� 64.� ATV 61WD30N4 51.000�7 50 69.5 56.8 45.7 �� 71.5 65 78.6 ATV 61WD37N4 64.00045 60 85.1 69.6 56 �� 85 77 9�.5 ATV 61WD45N4 65.00055 75 104.8 87 69 �5 10� 96 11�.� ATV 61WD55N4 9�.00075 100 140.� 11�.8 9�.� �5 1�7 1�4 150.7 ATV 61WD75N4 9�.00090 125 171.8 140.9 11� �5 16� 156 179.� ATV 61WD90N4 9�.000

    IP 54 drives with integrated category C1 EMC filterThree-phase supply voltage: 380…480 V 50/60 Hz

    0.75 1 1.8 1.5 1.� 5 �.� �.1 �.5 ATV 61W075N4C 19.0001.5 2 �.5 � �.� 5 4.1 �.4 4.5 ATV 61WU15N4C 19.000�.� 3 5 4.1 �.� 5 5.1 4.8 5.6 ATV 61WU22N4C �0.000� – 6.7 5.6 4.4 5 7.� 6.� 7.9 ATV 61WU30N4C �0.0004 5 8.8 7.4 5.8 5 9.1 7.6 10 ATV 61WU40N4C ��.0005.5 7 .5 11.4 9.� 7.5 �� 1� 11 1�.� ATV 61WU55N4C ��.0007.5 10 15.8 1�.� 10.4 �� 16 14 17.6 ATV 61WU75N4C ��.00011 15 �1.9 17.8 14.4 �� ��.5 �1 �4.7 ATV 61WD11N4C ��.00015 20 �0.5 �5.8 �0 �� �0.5 �7 ��.5 ATV 61WD15N4C 40.00018.5 25 �7.5 ��.� �4.7 �� �7 �4 40.7 ATV 61WD18N4C 51.000�� 30 4�.6 �6.6 �8.7 �� 4�.5 40 47.8 ATV 61WD22N4C 50.000�0 40 56.7 46.� �7.� �� 58.5 5� 64.� ATV 61WD30N4C 68.000�7 50 69.5 56.8 45.7 �� 71.5 65 78.6 ATV 61WD37N4C 85.00045 60 85.1 69.6 56 �� 85 77 9�.5 ATV 61WD45N4C 85.00055 75 104.8 87 69 �5 10� 96 11�.� ATV 61WD55N4C 119.00075 100 140.� 11�.8 9�.� �5 1�7 1�4 150.7 ATV 61WD75N4C 119.00090 125 171.8 140.9 11� �5 16� 156 179.� ATV 61WD90N4C 119.000Dimensions (overall) Drives W x H x D

    mmATV 61W075N4 (C)…WU�0N4 (C) �40 x 490 x �7�ATV 61WU40N4 (C), WU55N4 (C) �40 x 490 x �86ATV 61WU75N4 (C), WD11N4 (C) �60 x 5�5 x �86ATV 61WD15N4 (C) �95 x 560 x �15ATV 61WD18N4 (C), WD��N4 (C) �15 x 665 x �15ATV 61WD�0N4 (C) �85 x 7�0 x �15ATV 61WD�7N4 (C), WD45N4 (C) �85 x 880 x �4�ATV 61WD55N4 (C)…WD90N4 (C) �6� x 1000 x �64(1) These values are given for a nominal switching frequency of 8 kHz up to ATV 61WD15N4 or ATV 61WD15N4C, or 4 kHz for

    ATV 61WD18N4…WD90N4 or ATV 61WD18N4C…WD90N4C for use in continuous operation . The switching frequency is adjustable from 2…16 kHz for all ratings. Above 4 or 8 kHz, depending on the rating, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise . For continuous operation above the nominal switching frequency, derate the nominal drive current, see derating curves on our website “www.schneider-electric.com”.

    (2) Typical value for the indicated motor power and for the maximum prospective line Isc .Note: Consult the summary tables of possible drive, option and accessory combinations (see pages 42, 43, 46 and 47) .

    Variable speed drives Altivar 61 Supply voltage �80...480 V 50/60 Hz

    ATV 61W075N4

    PF1

    0749

    5

    ATV 61WD30N4C

    PF1

    0749

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • 19

    IP 54 drives with switch disconnector Vario and an integrated category C2 EMC filterThree-phase supply voltage: 380…480 V 50/60 Hz Motor Line supply Altivar 61Power indicated on rating plate (1)

    Line current (2)

    Apparent power

    Maximum prospective line Isc

    Maximum continuous current In(1)

    Maximum transient current for 60 s

    Reference Weight

    380 V 460 V380 V 480 V 380 VkW HP A A kVA kA A A A kg

    0.75 1 1.8 1.5 1.� 5 �.� �.1 �.5 ATV 61E5075N4 16.400

    1.5 2 �.5 � �.� 5 4.1 �.4 4.5 ATV 61E5U15N4 16.400

    �.� 3 5 4.1 �.� 5 5.1 4.8 5.6 ATV 61E5U22N4 16.400

    � – 6.7 5.6 4.4 5 7.� 6.� 7.9 ATV 61E5U30N4 16.400

    4 5 8.8 7.4 5.8 5 9.1 7.6 10 ATV 61E5U40N4 18.400

    5.5 7 .5 11.4 9.� 7.5 �� 1� 11 1�.� ATV 61E5U55N4 18.400

    7.5 10 15.8 1�.� 10.4 �� 16 14 17.6 ATV 61E5U75N4 ��.700

    11 15 �1.9 17.8 14.4 �� ��.5 �1 �4.7 ATV 61E5D11N4 ��.700

    15 20 �0.5 �5.8 �0 �� �0.5 �7 ��.5 ATV 61E5D15N4 �6.700

    18.5 25 �7.5 ��.� �4.7 �� �7 �4 40.7 ATV 61E5D18N4 45.400

    �� 30 4�.6 �6.6 �8.7 �� 4�.5 40 47.8 ATV 61E5D22N4 45.400

    �0 40 56.7 46.� �7.� �� 58.5 5� 64.� ATV 61E5D30N4 5�.800

    �7 50 69.5 56,8 45.7 �� 71.5 65 78.6 ATV 61E5D37N4 65.800

    45 60 85.1 69.6 56 �� 85 77 9�.5 ATV 61E5D45N4 65.800

    55 75 104.8 87 69 �5 10� 96 11�.� ATV 61E5D55N4 84.400

    75 100 140.� 11�.8 9�.� �5 1�7 1�4 150.7 ATV 61E5D75N4 84.400

    90 125 171.8 140.9 11� �5 16� 156 179.� ATV 61E5D90N4 84.400

    Dimensions (overall)Drives W x H x D

    ATV 61E5075N4…U�0N4 �40 x 490 x �96ATV 61E5U40N4, U55N4 �40 x 490 x �10ATV 61E5U75N4, D11N4 �60 x 5�5 x �10ATV 61E5D15N4 �95 x 560 x ��9ATV 61E5D18N4, D��N4 �15 x 665 x �40ATV 61E5D�0N4 �85 x 7�0 x ��5ATV 61E5D�7N4, D45N4 �85 x 880 x �8�ATV 61E5D55N4…D90N4 �6� x 1000 x 404(1) These values are given for a nominal switching frequency of 8 kHz up to ATV 61E5D15N4 or 4 kHz for

    ATV 61E5D18N4 . . .E5D90N4 drives for use in continuous operation .The switching frequency is adjustable from 2…16 kHz for all ratings.Above 4 or 8 kHz, depending on the rating, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise . For continuous operation above the nominal switching frequency, derate the nominal drive current, see derating curves on our website “www.schneider-electric.com”.

    (2) Typical value for the indicated motor power and for the maximum prospective line Isc .

    ATV 61E5D11N4

    PF0

    95�1

    References (continued) Variable speed drivesAltivar 61 IP 54 drives with switch disconnector Vario

    Variants:page �1

    Accessories:page ��

    Dialogue: page �1

    Drive-option combinations: page �8

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • �0

    Variable speed drives Altivar 61Supply voltage 500...690 V 50/60 Hz

    References (continued)1 References (continued)1

    IP 20 drivesMotor Line supply Altivar 61Power indicated on rating plate (1)

    Line current (2)

    Maximum prospective line Isc

    Maximum continuous current(1) (3)

    Reference (4) Weight

    500 V 575 V 500 V 600 V 500 V 575 VkW HP A A kA A A kgThree-phase supply voltage: 500…600 V 50/60 Hz

    �.� 3 7.6 6.7 �� 4.5 �.9 ATV61HU22S6X 7.500� – 9.9 10 �� 5.8 – ATV61HU30S6X 7.5004 5 1�.5 10.9 �� 7.5 6.1 ATV61HU40S6X 7.5005.5 7 .5 16.4 14.� �� 10 9 ATV61HU55S6X 7.5007.5 10 �1.4 18.4 �� 1�.5 11 ATV61HU75S6X 7.500Three-phase supply voltage: 500…690 V 50/60 Hz Motor Line supply Altivar 61Power indicated on rating plate (1)

    Line current(2)

    Maximum prospective line Isc

    Maximum continuous current(1) (3)

    Reference Weight

    500 V 575 V 690 V 500 V 600 V 690 V 500 V 575 V 690 VkW HP kW A A A kA A A A kg

    �.� 3 � 5.� 4.4 5.� �� 4.5 �.9 4.5 ATV 61HU30Y �0.000� – 4 6.8 – 6.6 �� 5.8 – 5.5 ATV 61HU40Y �0.0004 5 5.5 8.6 7.� 8.6 �� 7.5 6.1 7.5 ATV 61HU55Y �0.0005.5 7 .5 7.5 11.� 9.5 11.� �� 10 9 10 ATV 61HU75Y �0.0007.5 10 11 14.6 1�.� 15.5 �� 1�.5 11 1�.5 ATV 61HD11Y �0.00011 15 15 19.8 16.7 �0.� �� 18.5 17 18.5 ATV 61HD15Y �0.00015 20 18.5 �4.6 �0.7 �4 �� �4 �� �4 ATV 61HD18Y �0.00018.5 25 �� �9 �4 �7 �� �9 �7 �7 ATV 61HD22Y �0.000�� 30 �0 �� �8 �4 �� �5 �� �5 ATV 61HD30Y �0.000�0 40 �7 48 41 47 �� 47 41 4� ATV 61HD37Y 68.000�7 50 45 6� 51 55 �� 59 5� 54 ATV 61HD45Y 68.00045 60 55 68 57 6� �� 68 6� 6� ATV 61HD55Y 68.00055 75 75 79 67.0 8� �� 85 77 84 ATV 61HD75Y 68.00075 100 90 109 9� 101 �� 110 99 104 ATV 61HD90Y 68.00090 125 110 1�8 11� 117 �� 1�6 1�5 1�5 ATV 61HC11Y (4) 10�.000110 150 1�� 15� 1�� 1�7 �8 165 144 150 ATV 61HC13Y (4) 10�.0001�� – 160 18� 158.9 16� �8 �00 – 180 ATV 61HC16Y (4) 10�.000160 200 �00 �18 197 199 �5 �40 19� ��0 ATV 61HC20Y (4) 10�.000�00 250 �50 �77 �50 �57 �5 �1� �4� �90 ATV 61HC25Y (4) 181.000�50 350 �15 �4� �11 �17 �5 �90 ��6 �55 ATV 61HC31Y (4) 181.000�15 450 400 4�6 �90 �94 �5 46� 41� 4�0 ATV 61HC40Y (4) 181.000400 550 500 547 494 505 �5 590 5�8 54� ATV 61HC50Y (4) �8�.000500 700 6�0 67� 61� 616 4� 740 67� 675 ATV 61HC63Y (4) �8�.0006�0 800 800 847 771 775 4� 900 768 840 ATV 61HC80Y (4) �8�.000

    Dimensions (overall) Drives W x H x D

    mmATV 61HU��S6X…HU75S6X �10 x �95 x �1�ATV 61HU�0Y…HD�0Y �40 x 4�0 x ��6ATV 61HD�7Y…HD90Y ��0 x 6�0 x �90ATV 61HC11Y…HC�0Y �40 x 1190 x �77ATV 61HC�5Y…HC40Y 595 x 1190 x �77ATV 61HC50Y…HC80Y 11�0 x 1�90 x �77(1) These values are given for a nominal switching frequency of 4 kHz for ATV 61HUppS6X and for ATV 61HU30Y… HD30Y or

    2.5 kHz for ATV 61HD37Y…HC80Y for use in continuous operation. The switching frequency is adjustable from 2.5…6 kHz for ATV 61HUppS6X and for ATV 61HU30Y… HD30Y and from 2.5…4.9 kHz for ATV 61HD37Y…HC80Y drives. Above 2.5 kHz or 4 kHz, depending on the rating, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise . For continuous operation above the nominal switching frequency, derate the nominal drive current, see derating curves on our website “www.schneider-electric.com”.

    (2) Typical value for the indicated motor power and for the maximum prospective line Isc .(3) The maximum transient current for 60 seconds is equal to 120% of the maximum continuous current .(4) Line choke mandatory for ATV 61HC11Y…HC80Y drives, unless a special transformer is used (12-pulse) or when using the

    “387” variant for medium voltage motors (see page 22). The line choke must be ordered separately (see page 72).Note: Consult the summary tables of possible combinations: drives, options and accessories (see pages 44 to 47) .

    ATV 61HD45Y

    PF1

    0758

    �P

    F107

    5��

    PF1

    0758

    6

    ATV 61HC31Y+VW3 A4 572 (line choke mandatory) (4)

    ATV 61HU30S6X

    PF1

    0758

    1

    Variable speed drives:page 16

    Accessories:page ��

    Dialogue: page �1

    Drive-option combinations: page �8

    Variable speed drives:page 16

    Accessories:page ��

    Dialogue: page �1

    Drive-option combinations: page �8

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • �1

    Variable speed drive with additional power supplyWhen the power consumption table does not exceed �00 mA, ATV 61WpppN4 drives can be supplied with an additional �4 V c power supply, which allows additional consumption of �50 mA.

    In this case, add A24 at the end of the reference. For example: ATV 61W075N4 becomes ATV 61W075N4A24.

    Variable speed drive in a reinforced versionThis variant enables variable speed drives to operate in difficult ambient pollution conditions and complies with standard IEC607�1-�-� class �C�.

    ATV 61HD55M�X…HD90M�X, ATV 61HD90N4…HC6�N4 et ATV 61WpppN4A�4 drives are supplied as standard in a reinforced version.

    To order ATV 61H075M�…HU75M� and ATV 61H075N4…HD75N4 variable speed drives in a reinforced version, add S337 at the end of the reference.For example: ATV 61H075M� becomes ATV 61H075M3S337.

    To order ATV 61HD11M�X…HD45M�X drives in a reinforced version, add 337 at the end of the reference. For example: ATV 61HD11M�X becomes ATV 61HD11M3X337.

    In the reinforced version, the variable speed drive is supplied with a remote graphic display terminal.

    Variable speed drive with integrated terminalAll drives come with a remote graphic display terminal and an integrated terminal as standard.

    ATV 61H075M�…HD45M�X and ATV 61H075N4…HD75N4 drives can be ordered without a remote graphic display terminal. They will then have the integrated terminal only. In this case, add Z at the end of the reference. For example: ATV 61H075M� becomes ATV 61H075M3Z.

    Variable speed drive without DC chokeATV 61HD90N4…HC6�N4 drives are supplied with a DC choke as standard.

    They can be ordered without a DC choke for connections to the DC bus or when using a line choke (see page 70), by adding D at the end of the reference.For example: ATV 61HD90N4 becomes ATV 61HD90N4D.

    Variable speed drive with EMC plate conforming to NEMA type 12 standard

    ATV 61WpppN4 drives are supplied as standard with a European version EMC plate.

    To order drives with an EMC plate conforming to NEMA type 1� standard, add U at the end of the reference. This plate is supplied without a drill hole.For example: ATV 61W075N4 becomes ATV 61W075N4U.

    Note: - ATV 61H075M3…HD45M3X, ATV 61H075N4…HD75N4, ATV 61WpppN4C and ATV 61HU30Y…HD90Y drives are supplied as standard with a European version plate for EMC mounting - ATV 61HD55M3X…HD90M3X, ATV 61HD90N4…HC63N4 and ATV61HC11Y…HC80Y drives are supplied as standard without a plate for EMC mounting . Depending on the reference, the European version EMC plate is included in the UL Type 1 or IP 31 kit (see pages 24 and 25).

    Variable speed drives Altivar 61Variants

    Presentation, references

    Variable speed drives:page 16

    Accessories:page ��

    Dialogue: page �1

    Drive-option combinations: page �8

    Variable speed drives:page 16

    Accessories:page ��

    Dialogue: page �1

    Drive-option combinations: page �8

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • ��

    Low voltage drive for medium voltage motorsThis variant is an optimized solution for a medium voltage installation since it allows a low voltage drive to be used to control a medium voltage motor, thus offering a significant reduction in costs.

    Debugging and maintenance are also simpler and therefore less expensive.

    This variant is particularly suitable for pump and fan installations requiring low starting torque and/or long cable runs, such as submersible pumps, etc.

    The drive is supplied by a medium voltage/low voltage step-down transformer and controls the motor via a sinus filter and a lo� voltage/medium voltage step-up transformer.

    M1 3

    L1

    L2

    L3

    Medium voltage line supply

    MV/LV step-down transformer

    Altivar 61 low voltage drive Sinus filter

    LV/MV step-up transformer

    Medium voltage motor

    This variant allows use of a low voltage drive covering motor ratings from 110 kW to 800 kW for a medium voltage line supply between 700 V and 6600 V.

    To order ATV 61HC11N4D…HC6�N4D and ATV 61HC11Y…HC80Y drives in this variant, add 387 at the end of the reference.For example: ATV 61HC11N4D becomes ATV 61HC11N4D387.

    The sinus filter must be ordered separately (see page 83) by adding S387 at the end of the reference.For example: VW� A5 �07 becomes VW3 A5 207S387.For sinus filters used �ith ATV 61HpppY variable speed drives, please contact our Customer Care Centre.

    To determine the size of the drive and the step-up/step-down transformers, please contact our Customer Care Centre.

    Variable speed drives Altivar 61 Variants

    Presentation, references (continued)

    Variable speed drives:page 16

    Accessories:page ��

    Dialogue: page �1

    Drive-option combinations: page �8

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • ��

    Kit for flush-mounting in a dust and damp proof enclosure (for ATV 61Hppppp drives)

    This kit is used to mount the power section of the drive outside the enclosure. This solution considerably reduces dissipated losses in the enclosure (1).

    It is available for ATV 61HpppM�, ATV 61HpppM�X, ATV 61H075N4…HC�1N4, ATV 61HpppS6X, ATV 61HD90N4D…HC�1N4D and ATV 61HU�0Y…HC40Y drives.

    With this type of mounting, the maximum internal temperature in the enclosure can then reach 60°C without it being necessary to derate the drive current.Between 50°C and 60°C, a control card fan kit must be used for ATV 61HD��N4…HD75N4 and ATV 61HU�0Y…HD90Y drives to prevent hot spots (see page �8).

    The back of the enclosure must be drilled and cut out for this type of mounting.

    The kit consists of:b A metal frame of the right size for the drive rating,b Corner pieces,b Seals,b A fan support. This is used to re-position the fans so that they can be accessed from the front of the enclosure,b Fixing accessories,b A manual. ReferencesFor drives Reference Weight

    kgATV 61H075M�, HU15M�ATV 61H075N4…HU��N4

    VW3 A9 501 �.700

    ATV 61HU��M�…HU40M�ATV 61HU�0N4, HU40N4

    VW3 A9 502 �.100

    ATV 61HU55M�ATV 61HU55N4, HU75N4

    VW3 A9 503 �.700

    ATV 61HU75M�ATV 61HD11N4ATV 61HU��S6X…HU75S6X

    VW3 A9 504 4.600

    ATV 61HD11M�X, HD15M�XATV 61HD15N4, HD18N4

    VW3 A9 505 4.900

    ATV 61HD18M�X, HD��M�XATV 61HD��N4ATV 61HU�0Y…HD�0Y

    VW3 A9 506 �.900

    ATV 61HD�0N4, HD�7N4 VW3 A9 507 4.�00ATV 61HD�0M�X… HD45M�X VW3 A9 508 4.900ATV 61HD45N4… HD75N4ATV 61HD�7Y…HD90Y

    VW3 A9 509 5.�00

    ATV 61HD55M�X, HD75M�X ATV 61HD90N4, HC11N4 (2), ATV 61HD90N4D, HC11N4D

    VW3 A9 510 5.100

    ATV 61HD90M�X ATV 61HC1�N4 (2)ATV 61HC1�N4D

    VW3 A9 511 �.600

    ATV 61HC16N4 (2) ATV 61HC16N4DATV 61HC11Y…HC�0Y (3)

    VW3 A9 512 4.�00

    ATV 61HC��N4 (2) ATV 61HC��N4D

    VW3 A9 513 4.700

    ATV 61HC�5N4, HC�1N4 (2) ATV 61HC�5N4D, HC�1N4DATV 61HC�5Y…HC40Y (3)

    Without braking unit VW3 A9 514 4.700With braking unit VW3 A9 515 4.700

    (1) Power dissipated in the enclosure for dust and damp proof flush-mounting: please consult our website “www.schneider-electric.com”.

    (2) Drives supplied as standard with a DC choke: when mounting, cut out and drill the enclosure for the choke.

    (3) Drives supplied as standard with a transformer for the fan: when mounting, cut out and drill the enclosure for the transformer .

    ATV 61HC31N4D flush-mounted

    5�71

    79

    ATV 61HU75N4 flush-mounted

    5�71

    78

    Presentation, references

    Variable speed drives Altivar 61Accessories

    Variable speed drives:page 16

    Variants:page �1

    Dialogue: page �1

    Drive-option combinations: page �8

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • �4

    Kit for UL Type 1 conformity (mounting outside the enclosure)When the drive is mounted directly on a wall outside the enclosure, this kit can be used to ensure UL Type 1 conformity when connecting the cables with a tube.The shielding is connected inside the kit.

    For ATV 61HpppM�, ATV 61HD11M�X…HD45M�X, ATV 61H075N4…HD75N4, ATV 61HpppS6X and ATV 61HU�0Y…HD90Y drives, the kit consists of: b All the mechanical parts 1 including a pre-cut plate 2 for connecting the tubes 3, b Fixing accessories,b A manual.

    For ATV 61HD55M�X…HD90M�X, ATV 61HD90N4…HC�1N4, ATV 61HD90N4D…HC�1N4D and ATV 61HC11Y…HC40Y drives, the kit consists of: b An IP 54 casing 4 used to maintain the IP 54 degree of protection for the power section,b An EMC plate 5,b A UL Type 1 cover 7,b A pre-drilled plate 6 for connecting the tubes 3,b Fixing accessories,b A manual. ReferencesFor drives Reference Weight

    kgATV 61H075M�, HU15M�ATV 61H075N4…HU��N4

    VW3 A9 201 1.�00

    ATV 61HU��M�…HU40M�ATV 61HU�0N4, HU40N4

    VW3 A9 202 1.500

    ATV 61HU55M�ATV 61HU55N4, HU75N4

    VW3 A9 203 1.800

    ATV 61HU75M�ATV 61HD11N4ATV 61HU��S6X…U75S6X

    VW3 A9 204 �.000

    ATV 61HD11M�X, HD15M�XATV 61HD15N4, HD18N4

    VW3 A9 205 �.800

    ATV 61HD18M�X, HD��M�XATV 61HD��N4ATV 61HU�0Y…HD�0Y

    VW3 A9 206 4.000

    ATV 61HD�0N4, HD�7N4 VW3 A9 207 5.000ATV 61HD�0M�X… HD45M�X VW3 A9 217 7.000ATV 61HD45N4… HD75N4ATV 61HD�7Y…HD90Y

    VW3 A9 208 7.000

    ATV 61HD55M�X, HD75M�X ATV 61HD90N4, HC11N4 (1)ATV 61HD90N4D, HC11N4D (2)

    VW3 A9 209 9.400

    ATV 61HD90M�X ATV 61HC1�N4 (1)ATV 61HC1�N4D (2)

    VW3 A9 210 11.800

    ATV 61HC16N4 (1)ATV 61HC16N4D (2)ATV 61HC11Y…HC�0Y (3)

    VW3 A9 211 11.600

    ATV 61HC��N4 (1)ATV 61HC��N4D (2)

    VW3 A9 212 14.600

    ATV 61HC�5N4, HC�1N4 (1)ATV 61HC�5N4, HC�1N4D (2)ATV 61HC�5Y…HC40Y (3)

    Without braking unit VW3 A9 213 19.500With braking unit VW3 A9 214 19.500

    (1) Drives supplied as standard with a DC choke.(2) Drives supplied as standard without DC choke.(3) Drives supplied as standard with a transformer for the fan .

    Variable speed drives Altivar 61Accessories

    Presentation, references (continued)

    4 5 36

    7

    UL Type 1 conformity kits

    5�71

    8�

    1 2 3

    5�71

    84

    Variable speed drives:page 16

    Variants:page �1

    Dialogue: page �1

    Drive-option combinations: page �8

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • �5

    Variable speed drives Altivar 61Accessories

    Presentation, references (continued)

    Kit for IP 21 or IP 31 conformity (mounting outside the enclosure)When the drive is mounted directly on a wall outside the enclosure, this kit can be used to ensure IP �1 or IP �1 degree of protection when connecting the cables with a cable gland.The shielding is connected inside the kit.

    For ATV 61HpppM�, ATV 61HD11M�X…HD45M�X, ATV 61H075N4…HD75N4, ATV 61HpppS6X and ATV 61HU�0Y…HD90Y drives, the kit conforms to IP �1 degree of protection.Comprising: b All the mechanical parts 1 including a drilled plate 2 for attaching the cable glands 3,b Fixing accessories,b A manual.

    For ATV 61HD55M�X…HD90M�X, ATV 61HD90N4…HC6�N4, ATV 61HD90N4D…HC6�N4D and ATV 61HC11Y…HC80Y drives, the kit conforms to IP �1 degree of protection.Comprising: b An IP 54 casing 4 used to maintain the IP 54 degree of protection for the power section,b An EMC plate with cable clips 5,b An IP �1 cover 6,b Fixing accessories,b A manual. ReferencesFor drives Degree of

    protectionReference Weight

    kgATV 61H075M�, HU15M�ATV 61H075N4…HU��N4

    IP �1 VW3 A9 101 1.�00

    ATV 61HU��M�…HU40M�ATV 61HU�0N4, HU40N4

    IP �1 VW3 A9 102 1.500

    ATV 61HU55M�ATV 61HU55N4, HU75N4

    IP �1 VW3 A9 103 1.800

    ATV 61HU75M�ATV 61HD11N4ATV 61HU��S6X…ATV 61HU75S6X

    IP �1 VW3 A9 104 �.000

    ATV 61HD11M�X, HD15M�XATV 61HD15N4, HD18N4

    IP �1 VW3 A9 105 �.800

    ATV 61HD18M�X, HD��M�XATV 61HD��N4ATV 61HU�0Y…HD�0Y

    IP �1 VW3 A9 106 4.000

    ATV 61HD�0N4, HD�7N4 IP �1 VW3 A9 107 5.000ATV 61HD�0M�X… HD45M�X IP �1 VW3 A9 117 7.000ATV 61HD45N4… HD75N4ATV 61HD�7Y…HD90Y

    IP �1 VW3 A9 108 7.000

    ATV 61HD55M�X, HD75M�XATV 61HD90N4, HC11N4 (1)ATV 61HD90N4D, HC11N4D (2)

    IP �1 VW3 A9 109 9.400

    ATV 61HD90M�XATV 61HC1�N4 (1)ATV 61HC1�N4D (2)

    IP �1 VW3 A9 110 11.800

    ATV 61HC16N4 (1)ATV 61HC16N4D (2)ATV 61HC11Y…HC�0Y (3)

    IP �1 VW3 A9 111 11.600

    ATV 61HC��N4 (1)ATV 61HC��N4D (2)

    IP �1 VW3 A9 112 14.600

    ATV 61HC�5N4, HC�1N4 (1)ATV 61HC�5N4, HC�1N4D (2) ATV 61HC�5Y…HC40Y (3)

    Without braking unit

    IP �1 VW3 A9 113 19.500

    With braking unit

    IP �1 VW3 A9 114 19.500

    ATV 61HC40N4, HC50N4 (1)ATV 61HC40N4D, HC50N4D (2)

    IP �1 VW3 A9 115 �5.000

    ATV 61HC6�N4 (1)ATV 61HC6�N4D (2)ATV 61HC50Y…HC80Y (3)

    IP �1 VW3 A9 116 �5.000

    (1) Drives supplied as standard with a DC choke.(2) Drives supplied as standard without DC choke.(3) Drives supplied as standard with a transformer for the fan .

    4 5

    6

    IP 31 conformity kit

    5�71

    81

    1 2 3

    5�71

    80

    IP 21 conformity kit

    Variable speed drives:page 16

    Variants:page �1

    Dialogue: page �1

    Drive-option combinations: page �8

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • �6

    DNV kitThis kit enables Altivar 61 variable speed drives to satisfy the requirements of the DNV certification body.

    b�For the following variable speed drives:v �ATV 61HpppM�,v �ATV 61HD11M�X…HD45M�X,v �ATV 61H075N4…HD75N4.

    The kit consists of:v �Shock-absorbing mounts 1,v �An EMC input filter 2,v �EMC filter supports 3,v �Fixing accessories.

    It is mounted on the back of the variable speed drive on the additional EMC filter supplied with the DNV kit as standard.

    ReferencesFor drives Reference Weight

    kgATV 61H075M�, HU15M�ATV 61H075N4…HU��N4

    VW3 A9 621 5.400

    ATV 61HU��M�…HU40M�ATV 61HU�0N4, HU40N4

    VW3 A9 622 7.400

    ATV 61HU55M�ATV 61HU55N4, HU75N4

    VW3 A9 623 9.800

    ATV 61HU75M�ATV 61HD11N4

    VW3 A9 624 11.�00

    ATV 61HD11M�X, HD15M�XATV 61HD15N4, HD18N4

    VW3 A9 625 16.500

    ATV 61HD18M�X, HD��M�XATV 61HD��N4

    VW3 A9 626 �0.000

    ATV 61HD�0N4, HD�7N4 VW3 A9 627 ��.500

    ATV 61HD�0M�X… HD45M�XATV 61HD45N4… HD75N4

    VW3 A9 628 5�.500

    b�For ATV 61HU�0Y…HD�0Y variable speed drives The kit consists of:

    v �Shock-absorbing mounts 1,v �An EMC input filter,v �Fixing accessories.

    The shock-absorbing mounts are mounted on the back of the variable speed drive. The EMC filter is positioned beside the unit.

    ReferenceFor drives Reference Weight

    kgATV 61HU�0Y…HD�0Y VW3 A9 642 9.000

    b�For ATV 61HD�7Y…HD90Y variable speed drives The kit consists of:

    v �Shock-absorbing mounts 1,v �An EMC input filter,v �A line choke,v �Fixing accessories.

    The shock-absorbing mounts are mounted on the back of the variable speed drive. The EMC filter is positioned beside the unit. The line choke must be installed upstream of the drive.

    ReferenceFor drives Reference Weight

    kgATV 61HD�7Y…HD90Y VW3 A9 643 ��.000

    DF5

    �450

    0 1

    ATV 61HpppY drive mounted on DNV kit VW3 A9 64p

    2

    3

    1

    ATV 61HD11M3X drive mounted on DNV kit VW3 A9 625

    DF5

    �708

    1

    ATV 61HD45N4 drive mounted on DNV kit VW3 A9 628

    DF5

    600�

    76Presentation, references (continued)

    Variable speed drives Altivar 61Accessories

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

  • �7

    DNV kit (continued)b�For the following variable speed drives:

    v �ATV 61HD55M�X…HD90M�X,v �ATV 61HD90N4D…HC6�N4D,v �ATV 61HC11Y…HC80Y.

    The kit consists of:v �Shock-absorbing mounts 1,v �The mechanical fittings (rails and brackets) required for mounting 2,v �Fixing accessories.

    It is mounted on the back of the variable speed drive using the mechanical f