Convertible Floor/Ceiling/
Cooling only or
Reversible split-system
R22
MWX 512-518-524-536 GB+ TTK 512-
518-524-530-536 PB/RB/NB/ND
MWX 512-518-524-536 GB+ TWK 512-
518-524-530-536 PB/RB/NB/ND
R407C
MWX 512-518-524-536 GB+ TTK 512-
518-524-530-536 CB/CD
MS-PRC010-GB
© American Standard Inc. 2001
MS-PRC010-GB
Contents
3
Contents 3
Features and Benefits 4
Model Number Description 5
Application Considerations 6
General Data 7
Performance Data 11
Electrical Data 14
Dimensional Data 15
Typical Wiring Diagrams 28
Interconnecting Diagram 42
4 MS-PRC010-GB
Features and Benefits
Convertible console/
ceiling mounted indoor
unit MWX
Main components of the MWX
• 3-speed centrifugal fan motorassembly.
• Heat exchanger with aluminiumfins and copper tube.
• Washable air filters.• Multi- directional air louvres.• 2 versions : with or without
electric heater.• Colour : RAL 9002.
Outdoor units TTK/ TWK
Main components of outdoor units
TTK/ TWK single-circuit
• Axial fan motor assembly.• Rotary hermetic (sizes 512 to 524),
reciprocating (sizes 530 to 536NB/ND) or scroll (sizes 530 to 536CB/CD) compressor.
• Refrigerant charge R22 or R407C.• Integral condensate tray
(sizes 512 to 536).• Aluminium finned coil with copper
tubes.• Fan protection grille and
condenser coil.• Colour : RAL 9002.
5MS-PRC010-GB
Model Number Description
Indoor unit
Outdoor unit
TTK 5 12 C B
Electric characteristics :B = 230 V/1 Ph/50 Hz
Refrigerant compatibilityG = R22 and R407C
Nominal capacity in Mbh12 = 12 Mbh
Connections5 = Flare
ConfigurationMWX = Convertible - Reversible
Electric characteristics :B = 230 V/1 Ph/50 Hz
Refrigerant :P, R, N = R22C = R407C
Nominal capacity in Mbh12 = 12 Mbh
Connections5 = Flare
ConfigurationTTK = Outdoor unit - Cooling onlyTWK = Outdoor unit - Reversible
12 G B5MWX
6 MS-PRC010-GB
Application Considerations
Application of this product should be within the catalogued airflow and performance consideration.
Clearance requirementsThe recommended clearances identified with unit dimensions should be maintained to assure adequate serviceability,maximum capacity and peak operating efficiency. Actual clearances that appear inadequate should be reviewed withthe local TRANE representative.
Operating limits.
Table 1.1 R22 Refrigerant
Cooling mode Heating mode
Min. outdoor air temperature +10°C standard -7°C (TWK 512 to 524 PB/RB)-7°C with low ambient kit -12°C (TWK 530-536 NB/ND)
Max. outdoor air temperature +43°C +20°C
Recommended interconnecting lines - condensing units
Compressorunit
Blowerunit
Table 2
Max. length Max.level difference Line diameters
(m) (m) (inches)
L3 D2 D1 Gas Liquid
Outdoor unit
TTK 512 PB 20 12 15 1/2 1/4TTK 518 RB 24 18 24 5/8 3/8TTK 524 RB 24 18 24 5/8 3/8
TTK 530 NB/ND12 12 12 5/8 3/840 18 24 7/8
TTK 536 NB/ND18 18 18 3/4 3/840 18 24 7/8
TWK 512 PB 20 12 12 1/2 1/4TWK 518 RB 24 18 24 5/8 3/8TWK 524 RB 24 18 24 5/8 3/8
TWK 530 NB/ND12 12 12 5/8 3/840 18 24 7/8
TWK 536 NB/ND18 18 18 3/4 3/840 18 24 7/8
TTK 512 CB 19 11 17 1/2 1/4TTK 518 CB 20 18 18 5/8 3/8TTK 524 CB 30 18 28 5/8 3/8
TTK 530 CB/CD17 15 15 5/8 3/831 16 29 7/8
TTK 536 CB/CD 27 14 25 3/4 3/8
R407C
Cooling mode
Min. outdoor air temperature +10°C standard-7°C with low ambient kit
Max. outdoor air temperature +43°C
7MS-PRC010-GB
General Data
Table 3.1 : R22 Refrigerant
Split system, Cooling only Split system, reversible
Indoor unit MWX MWX MWX MWX MWX MWX MWX MWX MWX MWX
512 GB 518 GB 524 GB 536 GB 536 GB 512 GB 518 GB 524 GB 536 GB 536 GB
Outdoor unit TTK TTK TTK TTK TTK TWK TWK TWK TWK TWK
512 518 524 530 536 512 518 524 530 536
PB RB RB NB/ND NB/ND PB RB RB NB/ND NB/ND
Electrical power supply
Indoor unit (V/ Ph/ Hz) 230/1/50Outdoor unit (V/ Ph/ Hz) 230/1/50 230/1/50- 230/1/50 230/1/50-
400/3+N/50 400/3+N/50Capacity
Cooling capacity(1) (kW) 3.5 5.2 6.9 9.3 10.8 3.5 5.2 6.9 9.3 10.8Power input (Cooling mode) (kW) 1.4 2.2 2.9 3.6 4.3 1.4 2.2 2.9 3.6 4.3Heating capacity (2) (kW) - - - - - 3.7 6.0 7.4 9.7 11.2Power input (Heating mode) (kW) - - - - - 1.2 2.0 2.3 2.9 3.5Coefficient of performance - - - - - 3.1 3.0 3.2 3.3 3.2Current
Indoor unit Current amps (A) 0.47 0.52 0.7 0.7 0.7 0.47 0.52 0.7 0.7 0.7Indoor unit Current amps (3) (A) 9.2 13.5 18.1 26.8 26.8 9.2 13.5 18.1 26.8 26.8Outdoor unit Current amps (A) 6.5 10 11.8 20.2/27.8 23/9.3 6.5 10 11.8 20.2/7.8 23/9.3Indoor unit Start- up amps (A) 0.59 0.75 0.96 1.12 1.12 0.59 0.75 0.96 1.12 1.12Outdoor unit Start- up amps (A) 32 51 56 89/43 98/44 32 51 56 89/43 98/44Compressor
Number -Type 1- Rotary 1-Reciprocating 1- Rotary 1-ReciprocatingFan
Indoor unit Type CentrifugalOutdoor unit Type AxialAir flow
Indoor unit Low speed (m 3 /h) 510 555 765 1275 1275 510 555 765 1275 1275Indoor unit Medium speed (m 3 /h) 585 680 960 1420 1420 585 680 960 1420 1420Indoor unit High speed (m 3 /h) 680 810 1150 1550 1550 680 810 1150 1550 1550Outdoor unit (m 3 /h) 1050 2200 2200 3230 3230 1050 2200 2200 3230 3230Filter
Air filter Nber -Type 3- Polypropylene 4- Polypropylene 3- Polypropylene 4- PolypropyleneExpansion
Cooling mode Type/ Unit Capillary/outdoor Accutron/indoor Capillary/outdoor Accutron/indoorHeating mode Type/ Unit - - Accutron/outdoor Accutron/indoorRefrigerant connections
Indoor unit Flare gas - liquid (inch) 1/2-1/4 5/8-3/8 3/4-3/8 1/2-1/4 5/8-3/8 3/4-3/8Outdoor unit Flare gas- liquid (inch) 1/2-1/4 5/8-3/8 3/4-3/8 1/2-1/4 5/8-3/8 3/4-3/8
8 MS-PRC010-GB
Table 3.2: R22 Refrigerant
Split system, Cooling only Split system, reversible
Indoor unit MWX MWX MWX MWX MWX MWX MWX MWX MWX MWX
512 GB 518 GB 524 GB 536 GB 536 GB 512 GB 518 GB 524 GB 536 GB 536 GB
Outdoor unit TTK TTK TTK TTK TTK TWK TWK TWK TWK TWK
512 518 524 530 536 512 518 524 530 536
PB RB RB NB/ND NB/ND PB RB RB NB/ND NB/ND
Refrigerant charge
Outdoor unit (kg) 0.9 1.6 1.8 2.7 2.7 0.9 1.8 2.0 2.7 2.7Sound power level
Indoor unit L/ M/ H (dB( A)) 34/37/41 36/40/45 36/40/46 43/46/48 43/46/48 34/37/41 36/40/45 36/40/46 43/46/48 43/46/48Outdoor unit (dB( A)) 64 70 68 73 74 64 70 68 73 74Dimensions
Indoor unitLength (mm) 1085 1335 1585 1085 1335 1585Depth (mm) 248 268 248 268Height (mm) 622 622Outdoor unitLength (mm) 700 1018 1018 700 1018 1018Depth (mm) 253 360 360 253 360 360Height (mm) 530 595 798 530 595 798Dimensions (packed)
Indoor unitLength (mm) 1148 1398 1648 1148 1398 1648Depth (mm) 290 305 290 305Height (mm) 655 655Outdoor unitLength (mm) 810 1180 1180 810 1180 1180Depth (mm) 315 445 445 315 445 445Height (mm) 590 725 930 590 725 930Weight
Indoor unit (kg) 36 39 48 70 36 39 48 70Indoor unit with electric heater (kg) 37 40 50 72 37 40 50 72Outdoor unit (kg) 36 60 67 87 89 38 63 70 91 93Weight (packed)
Indoor unit (kg) 38 41 51 74 38 41 51 74Indoor unit with electric heater (kg) 39 42 53 76 38 42 53 76Outdoor unit (kg) 39 68 75 94 96 41 71 78 98 100Colour
Indoor unit RAL9002Outdoor unit RAL9002Recommended fuse size (system)
Current amps (A) 16 16 16 32/16 16 16 16 32/16Current amps (3) (A) 20 32 32 50/40 20 32 32 50/40
(1) In the following conditions: Outside temperature: 35ºC ; 27ºC DB, 19ºC WB; Return air temperature: 27ºC DB/19º C WB.(2) In the following conditions: Outside temperature: 7ºC DB/ 6ºC DB; Return air temperature: 20ºC DB.(3) With electric heater(4) Sound pressure levels: measurements taken in a furnished office with a reverberation time of 0.5 seconds
9MS-PRC010-GB
Table 4.1 : R407C Refrigerant
Split system, Cooling only
Indoor unit MWX MWX MWX MWX MWX
512 GB 518 GB 524 GB 536 GB 536 GB
Outdoor unit TTK TTK TTK TTK TTK
512 CB 518 CB 524 CB 530 CB/CD 536 CB/CD
Electrical power supply
Indoor unit (V/ Ph/ Hz) 230/1/50Outdoor unit (V/ Ph/ Hz) 230/1/50 230/1/50-400/3 +N/50Capacity
Cooling capacity(1) (kW) 3.4 5.3 6.9 9.4 / 9.1 11.1 / 10.9Power input (Cooling mode) (kW) 1.31 1.84 2.65 3.4 / 3.1 4.2 / 3.8Current
Indoor unit Current amps (A) 0.47 0.52 0.7 0.7 0.7Indoor unit Current amps (3) (A) 9.2 13.5 18.1 26.8 26.8Outdoor unit Current amps (A) 5.58 8.34 11.24 19.81 / 7.72 24.61 / 11.12Indoor unit Start- up amps (A) 0.59 0.75 0.96 1.12 1.12Outdoor unit Start- up amps (A) 28.7 44.0 72.0 97.04 / 45.54 116.04 / 52.04Compressor
Number -Type 1 - Rotary 1 - ScrollFan
Indoor unit Type CentrifugalOutdoor unit Type AxialAir flow
Indoor unit Low speed (m 3 /h) 510 555 765 1275 1275Indoor unit Medium speed (m 3 /h) 585 680 960 1420 1420Indoor unit High speed (m 3 /h) 680 810 1150 1550 1550Outdoor unit (m 3 /h) 1050 2200 2200 3230 3230Filter
Air filter Nber -Type 3- Polypropylene 4- PolypropyleneExpansion
Cooling mode Type/ Unit Capillary/outdoor Accutron/indoorRefrigerant connections
Indoor unit Flare gas - liquid (inch) 1/2-1/4 5/8-3/8 3/4-3/8Outdoor unit Flare gas- liquid (inch) 1/2-1/4 5/8-3/8 3/4-3/8
10 MS-PRC010-GB
Table 4.2 : R407C Refrigerant
Split system, Cooling only
Indoor unit MWX MWX MWX MWX MWX
512 GB 518 GB 524 GB 536 GB 536 GB
Outdoor unit TTK TTK TTK TTK TTK
512 CB 518 CB 524 CB 530 CB/CD 536 CB/CD
Refrigerant charge
Outdoor unit (kg) 0.9 1.6 1.8 2.5 2.5Sound power levelIndoor unit L/ M/ H (dB( A)) 34/37/41 36/40/45 36/40/46 43/46/48 43/46/48Outdoor unit (dB( A)) 64 70 68 73 74Dimensions
Indoor unitLength (mm) 1085 1335 1585Depth (mm) 248 268Height (mm) 622Outdoor unitLength (mm) 700 1018 1018Depth (mm) 253 360 360Height (mm) 530 595 798Dimensions (packed)
Indoor unitLength (mm) 1148 1398 1648Depth (mm) 290 305Height (mm) 655Outdoor unitLength (mm) 810 1180 1180Depth (mm) 315 445 445Height (mm) 590 725 930Weight
Indoor unit (kg) 36 39 48 70Indoor unit with electric heater (kg) 37 40 50 72Outdoor unit (kg) 36 60 67 87 89Weight (packed)
Indoor unit (kg) 38 41 51 74Indoor unit with electric heater (kg) 39 42 53 76Outdoor unit (kg) 39 68 75 94 96Colour
Indoor unit RAL9002Outdoor unit RAL9002Recommended fuse size type (system)
Indoor unitCurrent amps (A) 10 2 2 2 2Current amps (3) (A) 20 10 16 16 16Outdoor unit 25 / 10 32 / 16Current amps (A) / 16 25 32 32
(1) In the following conditions : Outside temperature : 35ºC ; 27ºC DB, 19º C WB ; Return air temperature : 27ºC DB/ 19ºC WB.(2) In the following conditions : Outside temperature : 7ºC DB/ 6ºC DB ; Return air temperature : 20ºC DB.(3) With electric heater(4) Sound pressure levels : measurements taken in a furnished office with a reverberation time of 0.5 seconds
11MS-PRC010-GB
Cooling capacitiesTable 5 : Cooling only system - R22 Refrigerant
Indoor unit Inside temperature Outside temperature (°C)
Outdoor unit (°C) DB/WB 25 30 32 35 40 43
TCC SHR TCC SHR TCC SHR TCC SHR TCC SHR TCC SHR
(kW) (kW) (kW) (kW) (kW) (kW)
MWX 512 GB 21/15 3.4 0.77 3.3 0.78 3.2 0.79 3.1 0.79 3.0 0.81 2.8 0.82+ 25/17 3.6 0.83 3.5 0.84 3.4 0.85 3.3 0.87 3.2 0.88 3.0 0.89
TTK 512 PB 27/19 3.9 0.77 3.7 0.78 3.7 0.78 3.5 0.80 3.4 0.82 3.3 0.8429/21 4.1 0.72 4.0 0.73 3.9 0.73 3.8 0.74 3.6 0.76 3.5 0.78
MWX 518 GB 21/15 5.0 0.73 4.8 0.75 4.7 0.75 4.7 0.75 4.5 0.76 4.4 0.77+ 25/17 5.4 0.78 5.2 0.80 5.1 0.80 5.0 0.81 4.8 0.82 4.7 0.83
TTK 518 RB 27/19 5.7 0.73 5.5 0.74 5.4 0.74 5.2 0.75 5.1 0.76 5.0 0.7829/21 6.1 0.68 5.8 0.69 5.7 0.70 5.6 0.71 5.4 0.72 5.2 0.72
MWX 524 GB 21/15 6.7 0.75 6.4 0.76 6.3 0.76 6.1 0.77 5.9 0.78 5.8 0.79+ 25/17 7.1 0.80 6.8 0.82 6.7 0.82 6.5 0.83 6.3 0.85 6.2 0.85
TTK 524 RB 27/19 7.5 0.75 7.1 0.77 7.0 0.77 6.9 0.77 6.7 0.79 6.5 0.8029/21 7.9 0.70 7.6 0.71 7.4 0.72 7.3 0.73 7.0 0.74 6.9 0.74
MWX 536 GB 21/15 9.5 0.75 8.9 0.76 8.7 0.77 8.4 0.78 7.8 0.80 7.5 0.82+ 25/17 10.2 0.80 9.6 0.82 9.4 0.83 9.0 0.84 8.4 0.87 8.1 0.89
TTK 530 NB/ND 27/19 10.9 0.74 10.3 0.76 10.0 0.77 9.7 0.78 9.1 0.80 8.7 0.8229/21 11.7 0.69 11.0 0.71 10.8 0.71 10.4 0.72 9.7 0.75 9.3 0.76
MWX 536 GB 21/15 10.5 0.72 10.0 0.74 9.7 0.74 9.4 0.75 8.8 0.77 8.4 0.78+ 25/17 11.3 0.77 10.7 0.78 10.5 0.79 10.1 0.80 9.4 0.83 9.1 0.84
TTK 536 NB/ND 27/19 12.1 0.71 11.5 0.73 11.2 0.74 10.8 0.75 10.1 0.77 9.7 0.7829/21 12.9 0.66 12.2 0.67 12.0 0.68 11.5 0.69 10.8 0.71 10.4 0.72
Table 6 : Cooling only system - R407c Refrigerant
Indoor unit Inside temperature Outside temperature (°C)
Outdoor unit (°C) DB/WB 25 30 32 35 40 43
TCC SHR TCC SHR TCC SHR TCC SHR TCC SHR TCC SHR
(kW) (kW) (kW) (kW) (kW) (kW)
MWX 512 GB 21/15 3.3 0.76 3.2 0.78 3.1 0.78 3.0 0.79 2.9 0.81 2.8 0.82+ 25/17 3.6 0.82 3.4 0.84 3.3 0.85 3.2 0.86 3.1 0.88 3.0 0.89
TTK 512 CB 27/19 3.8 0.76 6.6 0.78 3.5 0.79 3.4 0.80 3.3 0.82 3.2 0.8329/21 4.0 0.71 3.8 0.72 3.8 0.73 3.7 0.74 3.5 0.76 3.4 0.77
MWX 518 GB 21/15 5.1 0.73 4.8 0.74 4.7 0.75 4.6 0.76 4.4 0.77 4.3 0.78+ 25/17 5.4 0.78 5.2 0.79 5.1 0.80 5.0 0.81 4.7 0.83 4.6 0.84
TTK 518 CB 27/19 5.8 0.72 5.6 0.74 5.5 0.74 5.3 0.75 5.1 0.77 5.0 0.7829/21 6.2 0.67 6.0 0.68 5.8 0.69 5.7 0.70 5.5 0.71 5.3 0.72
MWX 524 GB 21/15 6.7 0.75 6.4 0.76 6.2 0.77 6.1 0.77 5.7 0.79 5.6 0.80+ 25/17 7.1 0.80 6.8 0.81 6.7 0.82 6.5 0.83 6.1 0.86 6.0 0.87
TTK 524 CB 27/19 7.6 0.74 7.3 0.76 7.1 0.77 6.9 0.78 6.5 0.80 6.3 0.8129/21 8.1 0.69 7.7 0.71 7.5 0.71 7.3 0.72 6.9 0.74 6.7 0.76
MWX 536 GB 21/15 9.1 0.76 8.7 0.77 8.5 0.78 8.2 0.79 7.7 0.81 7.4 0.82+ 25/17 9.8 0.81 9.3 0.83 9.1 0.84 8.8 0.85 8.2 0.88 7.9 0.90
TTK 530 CB 27/19 10.4 0.76 9.9 0.77 9.6 0.78 9.4 0.79 8.8 0.82 8.5 0.8329/21 11.1 0.70 10.5 0.72 10.3 0.73 10.0 0.74 9.4 0.76 9.1 0.77
MWX 536 GB 21/15 8.6 0.77 8.3 0.79 8.1 0.79 7.9 0.80 7.5 0.82 7.3 0.83+ 25/17 9.3 0.83 8.9 0.85 8.7 0.86 8.5 0.87 8.1 0.89 7.9 0.90
TTK 530 CD 27/19 9.9 0.77 9.5 0.79 9.3 0.80 9.1 0.81 8.6 0.83 8.4 0.8429/21 10.5 0.72 10.1 0.73 9.9 0.74 9.7 0.75 9.2 0.77 8.9 0.78
MWX 536 GB 21/15 10.8 0.72 10.3 0.73 10.0 0.73 9.8 0.74 9.2 0.76 8.8 0.77+ 25/17 11.5 0.76 11.0 0.78 10.7 0.78 10.4 0.79 9.8 0.81 9.5 0.82
TTK 536 CB 27/19 12.2 0.71 11.7 0.72 11.4 0.73 11.1 0.74 10.4 0.76 10.1 0.7729/21 13.0 0.66 12.4 0.67 12.1 0.68 11.8 0.69 11.1 0.70 10.7 0.71
MWX 536 GB 21/15 10.5 0.72 10.1 0.73 9.8 0.74 9.6 0.74 9.1 0.76 8.8 0.77+ 25/17 11.3 0.77 10.8 0.78 10.5 0.79 10.3 0.80 9.7 0.82 9.3 0.83
TTK 536 CD 27/19 12.0 0.71 11.5 0.73 11.2 0.73 10.9 0.74 10.3 0.76 10.0 0.7729/21 12.8 0.66 12.3 0.68 12.0 0.68 11.7 0.69 11.0 0.71 10.6 0.72
Performance Data
12 MS-PRC010-GB
Table 7 : Reversible system- R22 Refrigerant
Indoor unit Inside temperature Outside temperature (°C)
Outdoor unit (°C) DB/WB 25 30 32 35 40 43
TCC SHR TCC SHR TCC SHR TCC SHR TCC SHR TCC SHR
(kW) (kW) (kW) (kW) (kW) (kW)
MWX 512 GB 21/15 3.4 0.77 3.3 0.78 3.2 0.79 3.1 0.79 3.0 0.81 2.8 0.82+ 25/17 3.6 0.83 3.5 0.84 3.4 0.85 3.3 0.80 3.2 0.88 3.0 0.89
TWK 512 PB 27/19 3.9 0.77 3.7 0.78 3.7 0.78 3.5 0.74 3.4 0.82 3.3 0.8429/21 4.1 0.72 4.0 0.73 3.9 0.73 3.8 0.75 3.6 0.76 3.5 0.78
MWX 518 GB 21/15 5.0 0.73 4.8 0.75 4.7 0.75 4.7 0.81 4.5 0.76 4.4 0.77+ 25/17 5.4 0.78 5.2 0.80 5.1 0.80 5.0 0.75 4.8 0.82 4.7 0.83
TWK 518 RB 27/19 5.7 0.73 5.5 0.74 5.4 0.74 5.2 0.71 5.1 0.76 5.0 0.7829/21 6.1 0.68 5.8 0.69 5.7 0.70 5.6 0.77 5.4 0.72 5.2 0.72
MWX 524 GB 21/15 6.7 0.75 6.4 0.76 6.3 0.76 6.1 0.83 5.9 0.78 5.8 0.79+ 25/17 7.1 0.80 6.8 0.82 6.7 0.82 6.5 0.77 6.3 0.85 6.2 0.85
TWK 524 RB 27/19 7.5 0.75 7.1 0.77 7.0 0.77 6.9 0.73 6.7 0.79 6.5 0.8029/21 7.9 0.70 7.6 0.71 7.4 0.72 7.3 0.78 7.0 0.74 6.9 0.74
MWX 536 GB 21/15 9.5 0.75 8.9 0.76 9.7 0.77 8.4 0.78 7.8 0.80 7.5 0.82+ 25/17 10.2 0.80 9.6 0.82 9.4 0.83 9.0 0.84 8.4 0.87 8.1 0.89
TWK 530 27/19 10.9 0.74 10.3 0.76 10.0 0.77 9.7 0.78 9.1 0.80 8.7 0.82NB/ND 29/21 11.7 0.69 11.0 0.71 10.8 0.71 10.4 0.72 9.7 0.75 9.3 0.76
MWX 536 GB 21/15 10.5 0.72 10.0 0.74 9.7 0.74 9.4 0.75 8.8 0.77 8.4 0.78+ 25/17 11.3 0.77 10.7 0.78 10.5 0.79 10.1 0.80 9.4 0.83 9.1 0.84
TWK 536 27/19 12.1 0.71 11.5 0.73 11.2 0.74 10.8 0.75 10.1 0.77 9.7 0.78NB/ND 29/21 12.9 0.66 12.2 0.67 12.0 0.68 11.5 0.69 10.8 0.71 10.4 0.72
13MS-PRC010-GB
Heating capacitiesTable 8 : Reversible system - R22 Refrigerant
Indoor unit Outside temperature (°C) DB/WB
Outdoor unit Inside temperature -5/-5.5 -3/-4 2/1 7/6 12/10.5
(°C) HC COP HC COP HC COP HC COP HC COP
(kW) (kW) (kW) (kW) (kW)
MWX 512 GB 18 2.8 2.7 2.8 2.7 3.2 3.0 3.5 3.2 3.9 3.4+ 20 2.7 2.6 2.8 2.7 3.2 2.9 3.5 3.1 3.9 3.3
TWK 512 PB 24 2.7 2.5 2.8 2.5 3.1 2.7 3.5 2.9 3.9 3.0MWX 518 GB 18 4.3 2.7 4.6 2.8 5.1 2.9 5.7 3.1 6.3 3.2
+ 20 4.3 2.7 4.5 2.7 5.1 2.9 5.7 3.0 6.3 3.1TWK 518 RB 24 4.3 2.5 4.5 2.6 5.1 2.7 5.7 2.8 6.3 2.9MWX 524 GB 18 5.3 2.8 5.5 2.9 6.2 3.1 6.9 3.3 7.6 3.4
+ 20 5.3 2.8 5.5 2.8 6.2 3.0 6.9 3.2 7.6 3.3TWK 524 RB 24 5.2 2.6 5.5 2.7 6.1 2.8 6.9 3.0 7.6 3.0MWX 536 GB 18 6.7 2.8 7.1 2.9 8.1 3.1 9.3 3.3 10.5 3.5
+ 20 6.6 2.7 7.0 2.8 8.0 3.0 9.2 3.2 10.4 3.4TWK 530 NB/ND 24 6.3 2.5 6.7 2.6 7.8 2.8 8.9 3.0 10.1 3.2
MWX 536 GB 18 6.9 2.9 7.5 2.9 9.0 3.0 10.4 3.1 11.9 3.2+ 20 6.8 2.7 7.4 2.8 8.9 2.9 10.3 3.0 11.7 3.1
TWK 536 NB/ND 24 6.6 2.5 7.2 2.6 8.6 2.7 10.0 2.9 11.4 3.0
Table 9 : Electric heater heating capacities
Indoor unit MWX 512 GB MWX 518 GB MWX 524 GB MWX 536 GB
Heating capacity (kW) 2.0 3.0 4.0 6.0
Table 10 : Cooling and heating capacity correction factors
Fan speed
Low Medium High
Cooling capacity x 0.92 x 0.95 x 1.0Heating capacity x 0.94 x 0.97 x 1.0
14 MS-PRC010-GB
Electrical data
For recommended Fuse Size,Wire Section and Maximum Wire Length, refer toTable 3.1 to 4.2 Section “Recommended fuse size (system)”.
Table 19 : Control interconnectionOutdoor Unit Nbr Wires x Section area (mm²)TTK 512 PB/CB 3 x 1.5²TTK 518 RB/CB 2 x 1.5²TTK 524 RB/CB 2 x 1.5²TTK 530 NB/ND/CB/CD 2 x 1.5²TTK 536 NB/ND/CB/CD 2 x 1.5²TWK 512 PB 6 x 1.5²TWK 518 RB 5 x 1.5²TWK 524 RB 5 x 1.5²TWK 530 NB/ND 6 x 1.5²TWK 536 NB/ND 6 x 1.5²
Table 20 : Outdoor unit Power Supply(1)Outdoor Unit Nbr Wires x Section area (mm²)TTK 512 PB/CB -TTK 518 RB/CB 3 x 2.5²TTK 524 RB/CB 3 x 2.5²TTK 530 NB/CB 3 x 4²TTK 530 ND/CD 4x 2.5²TTK 536 NB/CB 3 x 4²TTK 536 ND/CD 4x 2.5²TWK 512 PB -TWK 518 RB 3 x 2.5²TWK 524 RB 3 x 2.5²TWK 530 NB/ND 3 x 4²/4x 2.5²TWK 536 NB/ND 3 x 4²/4x 2.5²
Table 21 : Indoor unit Power Supply (1)Without electric Heater With Electric Heater
Outdoor Unit Nbr Wires x Section area (mm²) Nbr Wires x Section area (mm²)MWX 512 GB 3 x 1.5² 3 x 2.5²MWX 518 GB 3 x 1.5² 3 x 2.5²MWX 524 GB 3 x 1.5² 3 x 4²MWX 536 GB 3 x 1.5² 4 x 4²
(1) Indoor and outdoor units are powered separately
15MS-PRC010-GB
Dimensional data
16 MS-PRC010-GB
17MS-PRC010-GB
18 MS-PRC010-GB
19MS-PRC010-GB
20 MS-PRC010-GB
21MS-PRC010-GB
22 MS-PRC010-GB
23MS-PRC010-GB
24 MS-PRC010-GB
25MS-PRC010-GB
26 MS-PRC010-GB
27MS-PRC010-GB
28 MS-PRC010-GB
Typical Wiring diagram
29MS-PRC010-GB
30 MS-PRC010-GB
31MS-PRC010-GB
32 MS-PRC010-GB
33MS-PRC010-GB
34 MS-PRC010-GB
35MS-PRC010-GB
36 MS-PRC010-GB
37MS-PRC010-GB
38 MS-PRC010-GB
39MS-PRC010-GB
40 MS-PRC010-GB
41MS-PRC010-GB
42 MS-PRC010-GB
Inderconnecting diagram
43MS-PRC010-GB
44 MS-PRC010-GB
45MS-PRC010-GB
46 MS-PRC010-GB
47MS-PRC010-GB
Literature Order Number MS-PRC010-GB
Date 0201
New
Stocking Location Europe
Société Trane – Société Anonyme au capital de 41500 000 F – Siege Social: 1 rue des Amériques –
88190 Golbey – France – Siret 306 050 188-00011 – RSC Epinal B 306 050 188
Numéro d’identification taxe intracommunanutaire: FR 83 3060501888
The Trane CompanyAn American Standard Companywww.trane.com
For more information contactyour local sales office ore-mail us at [email protected]
Since The Trane Company has a policy of continuous product improvement, it reserves the right to changedesign and specifications without notice.