Catalogo Seccionador Cut Out - Indel
-
Upload
yonatan-pallin-yalle -
Category
Documents
-
view
131 -
download
8
description
Transcript of Catalogo Seccionador Cut Out - Indel
As a professional power electric equipment manufacturer, we have been supplying our products (such as: Metal oxide Surge, Metal-oxide Varistro, Fuse Cutouts and Composite insulator, etc) for power electric transmission and distribution systems to customers world wide.
Products of uncompromising quality backed by comprehensive expertise and the competence gathered through years of expertise, have made us a prefered supplier of the industry Our high-voltage products are produced under ISO9001 certified quality management system. The quality is strictly controlled by cur own test laboratory (900kv Impluse Voltage Generater and 250KV Discharge Testing Equipment).
CANTOR is the firts manufacturer in China who has one-time adquired KEMA certifications covering over 27 type products. With our combination of technologies, CANTOR can offer reliable and cost effective overhead protection of distribution systems.
Brief Introduction
PROTECTION FORENERGY DISTRIBUTION
Technology withBetter, cost/Benefit
Tin-plated bronze terminals for use with copper or aluminun conductor
Copper current path
Bird-proofed one-piecesolid-porcelain insulator
Copper current path
Tin-plated bronze terminalsfor use with copper or aluminun conductor
Silver-to-silver contacts with stainless steelbackup springs
Cast bronze hinge for corrosolon resistance
Two-place locking to prevent sidemovementof hood, contacts or hooks
Galvanized steel channel
Stainless steel backupspring to maintain con-tact pressure
Silver-to-silver contacts
Galvanizaed steel hooks forloadbreak tool
Cast bronze top tube castingand pull ring
High-strength fiberglass fuse-tube coated with ultra-violetinhibitor
Hot stick hole in trunnion casting
Cast bronze lower tube casting
Fuseholder toggle latch limitstension of fuselink
Stainless steel spring ensuresproper toggle action of fuselink ejec-tor (cast-bronze on all 200A andlinkbreak fuscholders; stainless steelon all 100A)
Laboratory I
Laboratory II
INDELto the quality, invested in the consruction of its headquarters in the year 2001 with an area of 5.000 m2 where it produces his traditional products: Fuse Links and Braided.
In 2002 it continued investing buying and renovating a new area with 3.500 m2 to develop and produce newproducts to reach the expectations and necessities of the market, consolidating the brand INDEL
CUT - OUT FUSE DISTRIBUTION CLASS “D”
THE CUT-OUT FUSE DISTRIBUTION IS USED FOR THE PROTECTION OF EQUIPMENT IN DISTRIBUTION NETWORKS.
THE FUSEHOLDER WAS DESIGNED TO INTERRUP HIGH INTENSITY CURRENTS
IT CAN BE USE FOR OPERATIONS WITH CURRENT UP 300A, REPLACING THE FUSE FOR A SHEET COPPER.
MANUFACTURED IN ACCORDANCE WITH ABNT/ANSI/LEC.
FEATURES• PORCELAIN INSULATOR MADE IN CONFORMITY WITH ABNT, ANSI, AND
IEC.• MAIN CONTACT IN ELECTROLYTIC COPPER• DOBLE WAY PARARELL CONNECTORS IN TINNED COPPER, FOR CABLE
10-120 MM2º• HOOK FOR LOAD OPERATIONS• GALVANIZED STEAL HARDWARE
ACCESSORIES
MOUNTING HARDWARE IN ACCORDANCE WITH ABNT/ANSI C-37.40/41/42/IEC.
110 125NBINBI
Code
DNominal Current
Max. Voltage
CreepeDistance Dimensions
Nominal Current
Base
A KV KV (mm) L M N P Q A Sim. Ass. Brazil Export.
Fuseholder
Features and Dimensions
BrakingCapacity
LengthNBI
D-0210011015D-0410011015D-1010011015D-1210011015D-1610011015D-1020011015D-0610012527D-0810012527
1,42,87,18,0
10,67,14,55,3
2,04,0
10,012,016,010,0
6,38,0
300 15.0 110 240 550 450 407 50 50100 285
375 378
289
2.02.0±
± ±
±
100200
300 27.0 125 320 700 450 500 50 50
150 170NBI NBI
D-1210015038D-1220015038
Fuseholder
100A 200A
Note:• Have to beused with extention• Dimensions in milimeters• Doble way conector, 10 to 120 mm2 range
ARC Shortening
OptionalFuseholder 200 or Sheet copper Hord ware Stainler Steal
8.00
±0.
2
8.00
±0.
2
025.40 ±0.2
032.0 ±0.2
021.00 ±0.2 021.00 ±0.2
011.00 019.1 ± 0.5+35-0.0
012.
50 ±
0.2
012.
50 ±
0.2
56.00 ± 0.5
56.00 ± 0.5
“L”
75.00 Min.
75.00 Min.
Assembly Instructions
Hardware
5 = 15KV27 = 27KV38 = 38KV
00 = 100A200 = 200A
300 = 300A
-10 = 110KV--25 = 125KV-50 = 150KV-70 = 170KV200 = 200KV
02 = 2KA05 = 5KA06 = 6.3KA08 = 8KA-0 = 10KA-2 = 12KA-6 = 16KA
VOLTAGE
38 100 150 12 470 A A P
EXTENDERP= With extender
HARDWAREA= Type AB= Type BN= With out hardware
BOLTA= GALVANIZED
CREEPE DISTANCE2 = 240mm NBI 110KV3 = 320mm NBI 125KV4 = 470mm NBI 150KV6 = 660mm NBI 170KV
FUSEHOLDERCURRENT
CURRENT
NBI
BREAKINGCAPACITY
MIX CONFIGURATION TABLED