Catálogo Produal 2013

68
Catalogue 2013

Transcript of Catálogo Produal 2013

Page 1: Catálogo Produal 2013

PRODUAL l 1 l CAtALOgUe

Catalogue

2013

Page 2: Catálogo Produal 2013

PRODUAL l 2 l CAtALOgUe

Customer oriented expertisein measurement technologyProdual is an internationally operating pioneer of building automation measurement technology. the steady growth along with our customers during last years has enabled developing our operations according to the requirements of modern building construction. Reliable and accurate measurements facilitate the monitoring of energy efficiency, improve interior air quality and increase the comfort of occupants of the buildings.

Understanding the emerging requirements of building automation forms the foundation for our operation. We offer a wide and versatile product portfolio. Our devices have earned a reputation as reliable, easy-to-use and installation-friendly equipment, tried and tested in the decades of demanding use. We continuously invest in product development for new innovations and upgrading the basic products. Our customers are satisfied with the reachability of our representatives, and the fast and reliable deliveries. Based on the customer feedback, we constantly develop our operations, and have also strengthened our technical support, which is crucial to the customers in the field.

All the 68 Produal experts are very committed to keep on maintaining close relations with our customers – in Finland and elsewhere in europe!

this product list shows merely the foremost features of our products. We are engaged in constant development of our products and the current details and prices may be viewed on our website: www.produal.com /products.

PRODUAL Oy

Source and rights of the pictures on the cover and the introduction: Helsinki Music Centre / Arno Chapelle.

Page 3: Catálogo Produal 2013

PRODUAL l 3 l CAtALOgUe

5

6

7

8

9

10

11

COntentS

air velocity transmitters ........................................7differential pressure transmitters for air .............. 8–9air flow transmitters ............................................9air flow probe ......................................................10humidity transmitters ....................................... 11–12light level transmitters ............................................13

light level sensor ...................................................14differential pressure transmitters for water .............. 15pressure transmitters for water ............................ 15CO2 transmitters .......................................... 16–17carbon monoxide transmitters ............................. 17wind speed detector .......................................... 18rain sensor ....................................................... 19

heating/cooling water sensors ..............................27hot domestic water sensors .................................28frost guard sensors .............................................29strap-on sensors ................................................30duct sensors.................................................31–33cable temperature sensors ............................. 34–35cable temperature sensor, floor ............................36

cable temperature sensor, soil installation ..............36combustion gas sensors ......................................37room temperature sensors ..............................37–39outdoor air temperature sensors ..................... 39–40industrial temperature sensors .............................40temperature transmitters ..................................... 41

I/O modules ......................................................42transducers ................................................. 42–44transformers .....................................................45occupancy sensors .............................................46pir detectors .....................................................47

timers ..............................................................48push buttons .....................................................48indicator lights ...................................................49relays ......................................................... 49–50water leakage ................................................... 51

meters .............................................................57differential pressure switches ...............................58

control valves ....................................................59thermal actuators...............................................59

Produal Oy reserves the right to change the specifications without prior notification.

12

13

14

15

16

FROST PROTECTION CONTROLLERS ................................................................................4

HIGH TEMPERATURE ALARM THERMOSTATS .....................................................................4

ELECTRONIC THERMOSTATS ..........................................................................................5

TRANSMITTERS .........................................................................................................7

ELECTRIC POwER REGULATION ................................................................................... 19

TEMPERATURE CONTROLLERS .....................................................................................20

UNIvERSAL CONTROLLERS ......................................................................................... 25

TEMPERATURE MEASUREMENT .................................................................................... 27

TRANSDUCERS AND ACCESSORIES ............................................................................... 42

wIRELESS ............................................................................................................... 53

METERS, SwITCHES, vALvES AND ACTUATORS ............................................................... 57

TERMS OF DELIvERY ............................................................................................ 60–61

SENSOR SELECTION GUIDE .................................................................................... 62–63

SENSOR CHARACTERISTICS ........................................................................................ 64

CONTROLLER SELECTION GUIDE .................................................................................. 65

INDEX ................................................................................................................... 66

2

3

4

1

Page 4: Catálogo Produal 2013

PRODUAL l 4 l CAtALOgUe

Frost protection relays are protective devices for preventing heating coils from freezing in the air handling units.

Frost protection relays are protective devices for preventing heating coils from freezing in the air handling units.

High temperature alarm relay is a protective device monitoring duct temperatures in the air handling units.

supply 24 Vac/dc, 2 VA

range 0…+100 °C = 0…10 V

contact output 230 Vac, 10 A res.

alarm contact output 60 Vdc, 1 A

input /output signal 0…10 Vdc, 10 mA

housing IP20, for 35 mm DIn rail

supply 24 Vac, 2 VA

range 0…+100 °C = 0…10 V, 10 mA

contact output , AR 1 230 Vac, 10 A

alarm contact output 60 Vdc, 1 A

input / output signal 0(2)…10 V, 10 mA

housing IP20, 11-pole relay housing

supply 24 Vac/dc, 2 VA

range 0…+100 °C = 0…10 V

contact output 230 Vac, 10 A

alarm contact output 60 Vdc, 1 A

housing IP20, for 35 mm DIn rail

Type arT no.

Type arT no.

Type arT no.

JvA 24 1110110 forecasting, regulating; selectable sensor type (Pt1000, ni1000-Lg, PtC 1000/2000)

JvS 24 1110120 adjustable forecasting, regulating; selectable sensor type (Pt1000, ni1000-Lg, PtC 1000/2000)

EJv 24-PT 1110080 for Pt1000 sensor (1000 Ω / 0 °C), AR 1 relay included

Jv 24-PT 1110090 for Pt1000 sensor (1000 Ω / 0 °C), contact output 50 Vac 6 A res.

PvA 24 1110180 selectable sensor type (Pt1000, ni1000-Lg, PtC 1000/2000)

FROSt PROteCtIOn ReLAyS

FROSt PROteCtIOn ReLAyS

HIgH teMPeRAtURe ALARM ReLAyS

DIN housing

11-pole relay housing

DIN housing

1

2

Page 5: Catálogo Produal 2013

PRODUAL l 5 l CAtALOgUe

LK 24-Pt is a thermostat with an external Pt1000 temperature sensor input.

LeK 24-Pt is a temperature difference thermostat with two external Pt1000 temperature sensor inputs.

supply 24 Vac/dc, 2 VA

range -30…+30 °C or 0…+100 °C

input sensor input, Pt1000 (1000 Ω / 0 °C)

output 1 change-over contact, 230 V, 5 A res.,

by using AR 1 relay, 230 Vac, 10 A

output 2 0…10 V = -30…+30 °C

or 0…10 V = 0…+100 °C

housing IP20, 11-pole relay housing

supply 24 Vac/dc, 2 VA

range -30…+100 °C

difference setting 0…10 °C

hysteresis 0,2…5 °C

inputs sensor inputs, Pt1000 (1000 Ω / 0 °C)

output change-over contact 230 V, 5 A res.,

by using AR 1 relay, 230 Vac, 10 A

housing IP20, 11-pole relay housing

LK 24-PT 1120050 electronic thermostat, range -30…+30 °C

LK 24-PT 0/100 1120051 electronic thermostat, range 0…100 °C

LEK 24-PT 1120060 temperature difference thermostat

External Pt1000 temperature sensor, e.g. TEK PT 1000.

eLeCtROnIC tHeRMOStAtS

eLeCtROnIC tHeRMOStAtS

°C

Δ °C

3

Type arT no.

Type arT no.

Page 6: Catálogo Produal 2013

PRODUAL l 6 l CAtALOgUe

FRAnKFURt AIRPORt

HeAtHROW AIRPORt

Page 7: Catálogo Produal 2013

PRODUAL l 7 l CAtALOgUe

IVL air velocity transmitters are designed for measuring flow velocity inside the duct. Provided also with a temperature output.

VK 10 is a voltage controlled relay with an adjustable hysteresis.

supply 24 Vac/dc, < 1,5 VA

range, velocity IVL 10: 0…10 m/s, IVL 02: 0…2 m/s,

IVL 20: 0…20 m/s

range, temperature 0…+50 °C

output 1 velocity = 0…10 V < 2 mA

or 4…20 mA < 600 Ω

output 2 temperature 0…+50 °C = 0…10 V < 2 mA

or 4…20 mA < 600 Ω

ambient temperature 0…+50 °C

stem 10 mm x 200 mm

housing IP54, stem or cable gland downwards

mounting with flange, adjustable probe depth

supply 24 Vac, 2 VA

range 0…10 Vdc

setting range 0…100 %

hysteresis 0,5…5,0 V

output change over contact 230 V, 5 A res.

ambient temperature 0…+50 °C

housing IP20, 11-pole relay housing

IvL 10 1130010 air velocity transmitter 0…10 m/s, adjustable probe depth 50…190 mm

IvL 10-N 1130012 with display air velocity transmitter, 0…10 m/s, adjustable probe depth 50…190 mm

IvL 02 1130030 air velocity transmitter 0…2 m/s, adjustable probe depth 50…190 mm

IvL 02-N 1130031 with display air velocity transmitter, 0…2 m/s, adjustable probe depth 50…190 mm

IvL 20 1130050 air velocity transmitter 0…20 m/s, adjustable probe depth 50…190 mm

IvL 20-N 1130051 with display air velocity transmitter, 0…20 m/s, adjustable probe depth 50…190 mm

versions with 100 mm and 400 mm stems are also available, e.g. IvL 20-400.

vK 10 1130020 voltage controlled relay

AIR VeLOCIty tRAnSMItteRS

VOLtAge COntROLLeD ReLAy

m/s, °C

0...10 v control

4

Type arT no.

Type arT no.

Page 8: Catálogo Produal 2013

PRODUAL l 8 l CAtALOgUe

PeL differential pressure transmitters are designed for clean / isolation room applications. the transmitter zero point is kept accurate by using the regular automatic zeroing, eliminating the possible zero point drifting.

PeL 2500 differential pressure transmitters are designed for controlling pressures in the air handling units or detecting air volumes. Output signal can be selected either differential pressure linear or flow (volume) linear. the transmitter zero point is kept accurate by using the regular automatic zeroing, eliminating the possible zero point drifting.

supply 24 Vac/dc, 1.5 VA

range selectable at commissioning

output 0…10 Vdc < 2 mA or 4…20 mA < 900…1200 Ω

zeroing automatic; regularly eliminates the possible

zero point drifting

ambient temperature -10…+45 °C

housing IP54, cable gland downwards

mounting with screws, external lugs

supply 24 Vac/dc, 1.5 VA

range selectable at commissioning

output 0…10 Vdc, < 2 mA

zeroing automatic; regularly eliminates the possible

zero point drifting

ambient temperature -10…+45 °C

housing IP54, cable gland downwards

mounting with screws, external lugs

PEL 1131110 ranges 0…100, 0…200, 0…500, 0…1000, ±50, ±100, ±250 or ±500 Pa

PEL-N 1131111 with display, ranges identical with PeL

PEL 25K 1131220 ranges 0…2, 0…4, 0…7, 0…10, 0…15, 0…20 or 0…25 kPa

PEL 25K-N 1131221 with display, ranges identical with PeL 25K

PEL-AS 1131010 PeL accessory kit, includes 2 m hose and duct assemblies

PEL 2500 1131210 ranges ±100, 0…100, 0…200, 0…500, 0…1000, 0…2000 or 0…2500 Pa

PEL 2500-N 1131211 with display, ranges identical with PeL 2500

PEL-AS 1131010 PeL accessory kit, includes 2 m hose and duct assemblies

DIFFeRentIAL PReSSURe tRAnSMItteRS FOR AIR

DIFFeRentIAL PReSSURe tRAnSMItteRS FOR AIR

Pa

Pa

4

Type arT no.

Type arT no.

Page 9: Catálogo Produal 2013

PRODUAL l 9 l CAtALOgUe

PeL 1000 differential pressure transmitters are designed for fan controlling and air handling unit filter monitoring.

supply 24 Vac/dc, 1 VA

range selectable at commissioning

output 0…10 V, < 3 mA

ambient temperature 0…+50 °C

zeroing manual; process connections must be removed

before zeroing

housing IP54, cable gland downwards

mounting with screws, external lugs

DIFFeRentIAL PReSSURe tRAnSMItteRS FOR AIR

Pa

PEL 1000 1131140 range 0…500 or 0…1000 Pa

PEL 1000-N 1131141 with display, ranges identical with PeL 1000

PEL-AS 1131010 PeL accessory kit, includes 2 m hose and duct assemblies

IML is designed for detecting and controlling air flow in air handling units and rooms. IML-M has RS-485 connection for Modbus RtU communication.

supply 24 Vac/dc, 1.5 VA

range selectable at commissioning

output 1, air volume 0…10 Vdc, < 2 mA

output 2, diff. pressure or control 0…10 Vdc, < 2 mA

input, external set point 0…10 Vdc, < 2 mA

ambient temperature -10…+45 °C

housing IP54, cable gland downwards

mounting with screws, external lugs

IML 1131600 range 0...1000, 0...2000, 0...5000 or 0...7000 Pa

IML-M 1131611 IML for Modbus

PEL-AS 1131010 PeL accessory kit, includes 2 m hose and duct assemblies

AIR FLOW tRAnSMItteRSm3/s, m3/h, l/s, Pa

4

Type arT no.

Type arT no.

Page 10: Catálogo Produal 2013

PRODUAL l 10 l CAtALOgUe

PP air flow probes are designed for detecting air flow in the air handling systems. Different models with fixed Kv values are available for circular and rectangular ducts.

AIR FLOW PROBel/s

PP-PK R100 1250010 air flow volume probe for a circular 100 mm duct

PP-PK R125 1250020 air flow volume probe for a circular 125 mm duct

PP-PK R160 1250030 air flow volume probe for a circular 160 mm duct

PP-PK R200 1250040 air flow volume probe for a circular 200 mm duct

PP-PK R250 1250050 air flow volume probe for a circular 250 mm duct

PP-PK R315 1250060 air flow volume probe for a circular 315 mm duct

PP-PK R355 1250065 air flow volume probe for a circular 355 mm duct

PP-PK R400 1250070 air flow volume probe for a circular 400 mm duct

PP-PK R500 1250075 air flow volume probe for a circular 500 mm duct

PP-PK R700 1250077 air flow volume probe for a circular 700 mm duct

PP-SK L200 1250080 air flow volume probe for a 200 mm rectangular duct

PP-SK L250 1250090 air flow volume probe for a 250 mm rectangular duct

PP-SK L300 1250100 air flow volume probe for a 300 mm rectangular duct

PP-SK L350 1250110 air flow volume probe for a 350 mm rectangular duct

PP-SK L400 1250120 air flow volume probe for a 400 mm rectangular duct

PP-SK L450 1250130 air flow volume probe for a 450 mm rectangular duct

PP-SK L500 1250140 air flow volume probe for a 500 mm rectangular duct

PP-SK L550 1250150 air flow volume probe for a 550 mm rectangular duct

PP-SK L600 1250160 air flow volume probe for a 600 mm rectangular duct

PP-SK L650 1250170 air flow volume probe for a 650 mm rectangular duct

PP-SK L700 1250180 air flow volume probe for a 700 mm rectangular duct

PP-SK L750 1250190 air flow volume probe for a 750 mm rectangular duct

PP-SK L800 1250200 air flow volume probe for a 800 mm rectangular duct

PP-SK L850 1250210 air flow volume probe for a 850 mm rectangular duct

PP-SK L900 1250220 air flow volume probe for a 900 mm rectangular duct

PP-SK L950 1250230 air flow volume probe for a 950 mm rectangular duct

PP-SK L1000 1250240 air flow volume probe for a 1000 mm rectangular duct

PP-SK L1050 1250250 air flow volume probe for a 1050 mm rectangular duct

PP-SK L1100 1250260 air flow volume probe for a 1100 mm rectangular duct

PP-SK L1150 1250270 air flow volume probe for a 1150 mm rectangular duct

PP-SK L1200 1250280 air flow volume probe for a 1200 mm rectangular duct

Other lengths also available on request.

4 Type arT no.

Page 11: Catálogo Produal 2013

PRODUAL l 11 l CAtALOgUe

KLH and KLH-M room humidity transmitters are designed for detecting indoor relative humidity and temperature.

KLH 420 is a 2-wire humidity transmitter designed for detecting indoor relative humidity.

KLK 100 duct humidity transmitters are designed for detecting relative humidity and temperature inside ventilation ducts.

supply 24 Vac/dc, 1 VA

range 1 0…100 % rH

range 2 0…+50 °C

output 1, % rH 0…10 V = 0…100 % rH, 2 mA

output 2, °C 0…10 V = 0…+50 °C, 2 mA

housing IP20, ABS plastic

mounting with screws on wall or on a junction box (hole distance 60 mm)

operating voltage 12…35 Vdc

range 0…100 % rH

output, 2-wire transmitter 4…20 mA < 500 Ω (24 Vdc)

housing IP20, ABS plastic

mounting with screws on wall or on a junction box

(hole distance 60 mm)

supply 24 Vac/dc, < 1 VA

humidity range 0…100 % rH

temperature range -50…+50 °C

output 1, % rH 0…10 V < 2 mA /

4…20 mA < 600 Ω = 0…100 % rH

output 2, °C 0…10 V < 2 mA /

4…20 mA < 600 Ω = -50…+50 °C

ambient temperature -50…+50 °C

housing IP54, sensor or cable gland downwards

mounting with flange, adjustable probe depth < 150 mm

KLH 100 1132210 room humidity transmitter

KLH 100-N 1132211 room transmitter with display (humidity and/or temperature display)

KLH-M 1132600 room humidity transmitter for Modbus RtU gateway

KLH-M-N 1132601 room transmitter with display for Modbus RtU gateway (humidity and/or temperature display)

KLH 420 1132280 room humidity transmitter

KLH 420-N 1132281 room transmitter with humidity display

KLK 100 1132240 duct humidity transmitter

KLK 100-N 1132241 duct humidity transmitter with display

HUMIDIty tRAnSMItteRS

HUMIDIty tRAnSMItteRS

HUMIDIty tRAnSMItteRS

room % rH, °C

room % rH

duct % rH, °C

4

Type arT no.

Type arT no.

Type arT no.

Page 12: Catálogo Produal 2013

PRODUAL l 12 l CAtALOgUe

KLHJ 100 transmitters are designed for detecting relative humidity and temperature. the probe cable length is 2 m.

KLU 100 humidity and temperature transmitters are designed for outdoor applications.

supply 24 Vac/dc, < 1 VA

range 1 0…100 % rH

range 2 -50…+50 °C

output 1, % rH 0…10 V < 2 mA /

4…20 mA < 600 Ω = 0…100 % rH

output 2, °C 0…10 V < 1 mA /

4…20 mA < 600 Ω = -50…+50 °C

ambient temperature -50…+50 °C

sensor cable 2 m

housing IP54, cable gland downwards, (sensor IP50)

mounting transmitter with screws (external lugs), sensor

with flange, adjustable probe depth < 150 mm

supply 24 Vac/dc, < 1 VA

range 1 0…100 % rH

range 2 -50…+50 °C

output 1, % rH 0…10 V < 2 mA /

4…20 mA < 600 Ω = 0…100 % rH

output 2, °C 0…10 V < 1 mA /

4…20 mA < 600 Ω = -50…+50 °C

ambient temperature -50…+50 °C

housing IP54, sensor downwards

mounting with screws, external lugs

KLHJ 100 1132260 humidity and temperature transmitter

KLHJ 100-N 1132261 humidity and temperature transmitter with display

KLU 100 1132250 outdoor humidity transmitter

KLU 100-N 1132251 outdoor humidity transmitter with display

HUMIDIty tRAnSMItteRS

HUMIDIty tRAnSMItteRS

room/duct % rH, °C

outdoor % rH, °C

4

Type arT no.

Type arT no.

Page 13: Catálogo Produal 2013

PRODUAL l 13 l CAtALOgUe

Condensation switch KA 10 is designed for detecting water condensation in cooling systems, for example in cooling beams. With the condensation switch it is possible to control the cooling water supply when the water starts to condensate on the pipe. the KA 10-eXt model has an external condensation sensor.

supply 24 Vac/dc

outputs condensation information 0...10 Vdc

relay output 24 Vac/dc, 2 A

cable gland M16

ambient temperature 0...50 °C

housing IP54, cable gland downwards

COnDenSAtIOn SWItCH0...10 v output, relay output

KA 10 1187030 condensation switch

KA 10-EXT 1187031 condensation switch with external sensor, cable length 2 m

LUX 24 is designed for detecting room light level.

LUX 34 is designed for detecting outdoor light level and temperature. Measured values can be used for controlling lighting and heating.

supply 24 Vac, 1 VA

range 0…2000 lux

output 0…10 V < 5 mA or 4…20 mA < 500 Ω

ambient temperature 0…+50 °C

housing IP20

mounting by screws on wall or on junction box

supply 24 Vac/dc, < 0,1 VA

range, light level selectable at commissioning

range, temperature -50…+50 °C

output 1, light level 0…10 V, < 1 mA

output 2, temperature 0…10 V, < 1 mA = -50...+50 °C

ambient temperature -40…+40 °C

housing IP54, cable gland downwards

mounting with screws, external lugs

LUX 24 1133320 light level transmitter

LUX 34 1133310 light level transmitter, selectable range 0...1000 lux or 0...10000 lux

LUX 34-100 1133311 light level transmitter, selectable range 0...100 lux or 0...500 lux

LIgHt LeVeL tRAnSMItteRS

LIgHt LeVeL tRAnSMItteRS

room lux

outdoor lux, °C

4

Type arT no.

Type arT no.

Type arT no.

Page 14: Catálogo Produal 2013

PRODUAL l 14 l CAtALOgUe

LUX 11 is designed for detecting outdoor light level and temperature. temperature sensor can be either an ntC 10 or ntC 20 thermistor.

range, illumination level 0...800 lux = 30...3 kΩ

range, temperature -50...+50 °C

sensor, illumination level photo resistive cell

sensor, temperature ntC 10 or ntC 20

housing IP54, cable gland downwards

mounting with screws, external lugs

LUX 11 + NTC 10 1133350 illumination and temperature sensor (ntC 10)

LUX 11 + NTC 20 1133351 illumination and temperature sensor (ntC 20)

LIgHt LeVeL SenSORoutdoor lux, °C

MMSP1 is designed for detecting sun light intensity.

supply 5...30 Vdc, 30 mW

range 0...1500 W/m2

accuracy ±5 % (annual mean)

outputs 0...10 Vdc*, 0...3.125 Vdc, 0...150 mVdc or 4...20 mA

housing IP65

* the supply voltage must be at least 12 V

MMSP1 1133360 sun light intensity transmitter

LIgHt IntenSIty tRAnSMItteRoutdoor w/m2

4

Type arT no.

Type arT no.

Page 15: Catálogo Produal 2013

PRODUAL l 15 l CAtALOgUe

VPeL differential pressure transmitter is designed for detecting water/glycol pressures in heating and cooling systems.

VPL pressure transmitter (3-wire) is designed for detecting fluid pressures in heating and cooling systems.

supply 24 Vac/dc, 1 VA

ranges see type

output 0…10 V, < 5 mA or 4...20 mA < 500 Ω

ambient temperature -20…+70 °C

process connections 8 mm compression fittings for copper pipes

housing IP54

mounting with screws, external lugs, position allowed

only process connectors downwards

zeroing manually by using the push button

supply 24 Vac/dc, 1 VA

range selectable

output 1 0…10 V < 2 mA

output 2 4…20 mA < 800 Ω

ambient humidity non-condensing

ambient temperature 0…+60 °C

housing IP54, cable gland or process connection

downwards

mounting R ½”, wetting parts stainless steel

allowed media fresh water, air, glycol & water, oils

allowed media temperature 0…+85 °C

vPEL 1.0/2.5 1134060 range selectable 0…1.0 or 0…2.5 bar

vPEL 1.0/2.5-N 1134061 with display

vPEL 4.0/6.0 1134070 range selectable 0…4.0 or 0…6.0 bar

vPEL 4.0/6.0-N 1134071 with display

DIFFeRentIAL PReSSURe tRAnSMItteRS FOR WAteR

PReSSURe tRAnSMItteRS FOR WAteR

bar

bar

vPL 16 1134050 pressure transmitter, range selectable 0…2.5, 0…6, 0…10 or 0…16 bar

vPL 16-N 1134051 pressure transmitter with display

vPL 60 1134030 pressure transmitter, range selectable 0…16, 0…25, 0…40 or 0…60 bar

vPL 60-N 1134031 pressure transmitter with display

4

Type arT no.

Type arT no.

Page 16: Catálogo Produal 2013

PRODUAL l 16 l CAtALOgUe

HDH transmitters are designed for detecting CO2 and temperature in dry room spaces. RH models have also the relative humidity measurement. the CO2 sensor zero point is calibrated regularly by using the ABCLogic™ function.

HDK transmitters are designed for detecting CO2 inside the ventilation ducts. the CO2 sensor zero point is calibrated regularly by using the ABCLogic™ function.

supply 24 Vac/dc, 2,5 VA

range, CO2 0…2000 ppm

range, temperature 0…+50 °C

accuracy, CO2 ±40 ppm +3 % of value

accuracy, temperature ±0,5 °C

outputs 0…10 V, < 2 mA

ambient temperature 0…+50 °C

housing IP20, ABS plastic

mounting with screws on wall or on junction box

supply 24 Vac/dc, 2,5 VA

range CO2 0…2000 ppm

range temperature 0…+50 °C

accuracy ±40 ppm +3 % of value

output 0…10 V, < 2 mA

ambient temperature 0…+50 °C

housing IP54, cable gland downwards

duct mounting in a Ø 10 mm hole, fixing by a flange and screws,

external lugs

HDH 1135040 room transmitter, CO2 and temperature measurement

HDH-N 1135041 room transmitter with display

HDH-C 1135042 controller and calibration tool for HDH

HDH-RH 1135044 room transmitter, CO2, temperature and humidity measurement

HDH-RH-N 1135045 room transmitter with display

HDH-AL3 1135048 option for HDH, 3 leds indicating different CO2 concentrations

HDH-M 1135100 Modbus room transmitter, CO2 and temperature measurement

HDH-M-N 1135101 Modbus room transmitter with display

HDH-M-RH 1135102 Modbus room transmitter, CO2, temperature and humidity measurement

HDH-M-RH-N 1135103 Modbus room transmitter with display

HDHFL 1191150 room transmitter with wireless communication, CO2 and temperature measurement

HDHFL-N 1191151 room transmitter with wireless communication and with display

HDHFL-RH 1191160 room transmitter with wireless communication, CO2, temperature and humidity measurement

HDHFL-RH-N 1191161 room transmitter with wireless communication and with display

HDK 1135050 duct transmitter

HDK-N 1135051 duct transmitter with display

HDK-C 1135052 controller and calibration tool for HDK and HDU

CO2 tRAnSMItteRS

CO2 tRAnSMItteRS

room ppm CO2, °C, % rH

duct ppm CO2, °C

4

Type arT no.

Type arT no.

Page 17: Catálogo Produal 2013

PRODUAL l 17 l CAtALOgUe

HDU transmitters are designed for detecting CO2 concentration in underground parking garages and parking halls. the CO2 sensor zero point is calibrated regularly by using the ABCLogic™ function.

HML transmitters are designed for detecting carbon monoxide concentration in underground parking garages and parking halls. the measuring is based on electro-chemical cell. the transmitter measuring range is 0…100 or 0…300 ppm.

supply 24 Vac/dc, 2,5 VA

range, CO2 0…2000 ppm

range, temperature -50…+50 °C

accuracy ±40 ppm +3 % of value

outputs 0…10 V, < 2 mA

ambient temperature -30…+50 °C

housing IP54, cable gland downwards

mounting with screws, external lugs

supply 24 Vac/dc, 3 VA

range 0…100 ppm or 0…300 ppm CO

accuracy 10 ppm/±10 ppm or 15 % of measured value

output 0…10 V or 4…20 mA

ambient temperature -30…+40 °C

housing IP54, cable gland downwards

mounting with screws, external lugs

Type arT no.

HDU 1135090 CO2 transmitter for cold spaces

HDU-N 1135091 CO2 transmitter with display

HDK-C 1135052 controller and calibration tool for HDK and HDU

CO2 tRAnSMItteRS

CARBOn MOnOXIDe tRAnSMItteRS

outdoor ppm CO2, °C

outdoor ppm CO

HML 1135520 CO transmitter

HML-N 1135521 CO transmitter with display

HMv 1135510 exchange kit for HML

HML-C 1135522 calibration tool for HML

HM-vS 1135523 flow controller for HML

HM-KK 1135524 reference gas for HML

4

Type arT no.

Page 18: Catálogo Produal 2013

PRODUAL l 18 l CAtALOgUe

tUnA 20 is designed for measuring wind speed and outside air temperature.

supply 24 Vac/dc, < 1,5 VA

range, velocity 0...20 m/s

range, temperature -50…+50 °C

outputs 0...10 V, < 2mA

4...20 mA, < 600 Ω

ambient temperature -50…+50 °C

housing IP54 (transmitter)

mounting wall mounting with screws

TUNA 20 1136010 wind speed detector

WInD SPeeD DeteCtOR m/s, °C

UV7 ultrasonic wind sensor is designed for measuring wind speed and direction in HVAC applications. the sensor is robust and stable.

supply 24 Vdc/ac

range, wind direction 0...359°

range, wind speed 0.1...15 m/s or 0.1...30 m/s

accuracy, wind direction ±1°

accuracy, wind speed ±0.1 m/s

outputs 3 x 0...10 Vdc

RS232 nMeA0183®

ambient temperature -10...+55 °C

housing IP67

Uv7 1136030 wind sensor

Uv7-B 1136031 wind sensor bracket for Ø50 mm mast

Uv7-vv 1136032 transmitter module for wind sensor

WInD SenSOR m/s, °

VS 3000 wind sensor is designed for measuring wind speed and direction in HVAC applications.

supply 24 Vac/dc

range, wind direction 0...360 <°

range, wind speed 0...35 m/s

output 0...10 Vdc

ambient temperature -35...+70 °C

housing IP65

vS 3000 1136040 wind speed and direction sensor

vH 1000 1136050 wind speed sensor

vR 1000 1136060 wind direction sensor

WInD SenSOR m/s, °

4

Type arT no.

Type arT no.

Type arT no.

Page 19: Catálogo Produal 2013

PRODUAL l 19 l CAtALOgUe

SA 10 is designed for detecting and monitoring rain in HVAC applications.

supply 24 Vac/dc, < 5 VA

range weak rain approx. 1 V, 0,5 mm/h

normal rain approx. 2…3 V

heavy rain approx. 3…10 V

outputs 0…10 V, < 2 mA

relay nO 60 Vdc, 0,1 A

ambient temperature range -40…+50 °C

housing IP54

mounting by a band to a mast (Ø 25…60 mm) or by

screws on the wall (hole distance 68 mm)

SA 10 1136020 rain sensor

RAIn SenSOR

BAK 64 binary step controller is designed for controlling electric heating power. It can be used with all systems with 0…10 V outputs. Relays like AR 1 or Ry 1 are needed for contact outputs. Power steps must be in binary sequence e.g. 1, 2, 4, 8, 16, 32 kW.

supply 24 Vac, 3 VA

input 0…10 Vdc or 10…0 Vdc, selectable

outputs 1-6 < 40 Vdc 100 mA, valid for AR 1 and Ry 1 relays

delay between steps adjustable, 0,7…60 s

housing IP20, 11-pole relay housing

eLeCtRIC POWeR RegULAtIOn

BAK 64 1140010 binary step controller

AR 1 1183010 relay, normally open (no) contact 230 Vac, 10 A

RY 1 1183020 relay, change-over contact 230 Vac, 10 A

4

Type arT no.

Type arT no.

5

Page 20: Catálogo Produal 2013

PRODUAL l 20 l CAtALOgUe

StS 4 converts 0…10 V signal to one time proportional and up to 3 contact outputs. each step must be identical in power.

HLS 16 is a 1-stage controller for room temperature control. Both heating and cooling are controlled by using the same valve. the function of the valve can be changed by using external (summer/winter) switch connected to the Z1 terminal.

StS 1 controls time proportionally electric power of heaters in cycles of 20 s.

supply 24 Vac, 1 VA

input 0…10 Vdc < 1 mA

output 1 for solid state relay 15 Vdc < 50 mA, time proportional

outputs 2-4 40 Vdc < 100 mA, valid for AR 1 and Ry 1 relays

number of steps selectable, 1-4 pcs

housing IP20, 11-pole relay housing

supply 24 Vac, 1 VA

input 0…10 Vdc < 1 mA

output 230 Vac < 4 A, time proportional (cycle 20 s)

housing IP20, for 35 mm DIn rail

dimensions 22 x 77 x 51 mm

eLeCtRIC POWeR RegULAtIOn

teMPeRAtURe COntROLLeRS

eLeCtRIC POWeR RegULAtIOn

room °C

STS 1 1140040 time proportional power controller

STS 4 1140020 electric power controller

PR 50/440 1140030 solid state relay 230…400 Vac, < 25 A, input 8…32 Vdc

PR 10/440 1140060 solid state relay 230…400 Vac, < 10 A, input 3…32 Vdc

PRMK 1140070 solid state relay control signal converter, Vac -> Vdc

AR 1 1183010 relay, normally open (no) contact 230 Vac, 10 A

RY 1 1183020 relay, change-over contact 230 Vac, 10 A

PJR 4 1140050 solid state relay, input 24 Vac/dc, output 230 Vac < 4 A, IP20, for 35 mm DIn rail

HLS 16 1150160 controller for floor heating/cooling

HLS 16-N 1150161 with display

supply 24 Vac, 2 VA

set point +18…+24 °C, ±3°C

accuracy ±0,5 °C

outputs A1 (nC) and A2 (nO) 24 Vac, 1 A for thermal actuator

ambient temperature 0…+50 °C

housing IP20, ABS plastic

mounting with screws on wall or on a junction box

(hole distance 60 mm)

StS 4 PR 50/440 Ry 1

5

Type arT no.

Type arT no.

Type arT no.

6

Page 21: Catálogo Produal 2013

PRODUAL l 21 l CAtALOgUe

HLS 21 is a 2-stage controller for room temperature control. the controller has one thermal (PWM) actuator stage for both heating and cooling.

HLS 33 is a room temperature controller with 2 or 3 stages. One stage is for heating and up to two stages for cooling. the controllers can be used with 0…10 V, 3-point or thermal (PWM) actuators.

supply 24 Vac, 2 VA

set point +18…+24 °C, ±3 °C

output A1, cooling 24 Vac < 1 A thermal actuator

output A2, heating 24 Vac < 1 A thermal actuator

ambient temperature 0…+50 °C

housing IP20, ABS plastic

mounting with screws on wall or on a junction box

(hole distance 60 mm)

supply 24 Vac, 2 VA

set point +18…+24 °C, ±3 °C

output y1, cooling 0…10 V / 10…0 V < 2 mA

output y2, heating 0…10 V / 10…0 V < 2 mA

output A1, cooling 24 Vac < 1 A, 3-point or thermal actuator

output A2, heating 24 Vac < 1 A, 3-point or thermal actuator

ambient temperature 0…+50 °C

housing IP20, ABS plastic

mounting with screws on wall or on a junction box

(hole distance 60 mm)

HLS 21 1150100 controller with internal temperature sensor

HLS 21-N 1150101 with display

HLS 21-EXT 1150102 controller for an external ntC10 temperature sensor

HLS 21-N-EXT 1150103 controller for an external ntC10 temperature sensor and display

teMPeRAtURe COntROLLeRS

teMPeRAtURe COntROLLeRS

room °C

room °C

HLS 33 1150090 controller with internal temperature sensor

HLS 33-N 1150091 with display

HLS 33-EXT 1150092 controller for an external ntC10 temperature sensor

HLS 33-N-EXT 1150093 for an external ntC10 temperature sensor with display

TH 5 1183090 driver for thermal actuators

External NTC 10 temperature sensor, e.g. TEKHA NTC 10.

6

Type arT no.

Type arT no.

Page 22: Catálogo Produal 2013

PRODUAL l 22 l CAtALOgUe

HLS 34 is a room temperature controller with RS-485 connection for Modbus RtU communication. the set point and fan speed can be adjusted by using the display and push buttons. Commissioning can be made by using push buttons or by using HLS 34-SeR configuration tool. e.g. occupancy or CO2 sensor can be connected to the controller.

HLS 35 is a controller for floor heating and cooling. HLS 35 is especially suitable for floor heating and cooling applications when there is a possibility to change the supply water from heating to cooling in the summer time. the controller has RS-485 connection for Modbus RtU communication.

supply 24 Vac/dc < 1 VA

nOte: Only the 0…10 V outputs and Modbus work

when using DC supply voltage.

set point adjusting by push buttons or by modbus communication

output y1, cooling 0…10 V / 10…0 V < 2 mA

output y2, heating 0…10 V / 10…0 V < 2 mA

output A1, cooling 24 Vac < 1 A, 3-point or thermal actuator

output A2, heating 24 Vac < 1 A, 3-point or thermal actuator

ambient temperature 0…+50 °C

housing IP20

mounting with screws on wall or on a junction box

(hole distance 60 mm)

teMPeRAtURe COntROLLeRS

teMPeRAtURe COntROLLeRS

room °C

floor °C

HLS 34 1150110 room temperature controller with Modbus, contains display, 4 buttons

HLS 34-2B 1150112 like HLS 34, buttons: + and -

HLS 34-3B 1150113 like HLS 34, buttons: +, - and day extension

HLS 34 -SER 1150111 configuration tool for HLS 34

TH 5 1183090 driver for thermal actuators

FCRY 3 1183070 fan coil relay

External NTC 10 temperature sensor, e.g. TEKHA NTC 10.

supply 24 Vac/dc, < 1 VA

nOte: Only the 0…10 V output and

Modbus work when using DC supply voltage.

input, return water 1 x ntC 10 temperature

input, summer/winter 1 x digital input

output, control valve 1 x 0…10 Vdc

output, heating/cooling 24 Vac, < 1 A, 3-point or thermal actuator

ambient temperature 0…+50 °C

housing IP20

mounting with screws on wall or on a junction box

(hole distance 60 mm)

HLS 35 1150130 room temperature controller for floor heating (modbus), contains display

TEL NTC 10 1175280 floor sensor with 3 m cable

6Type arT no.

Type arT no.

Page 23: Catálogo Produal 2013

PRODUAL l 23 l CAtALOgUe

HLS44 is a multifunctional controller designed especially for individual room temperature and zone control applications. Controller has a galvanically isolated RS-485 connection for Modbus RtU communication.

HLS44-V is a multifunctional controller designed especially for individual room temperature and light control applications. Controller has a galvanically isolated RS-485 connection for Modbus RtU communication.

supply 24 Vac/dc, < 1 VA

nOte: Only the 0…10 V outputs and Modbus work

when using DC supply voltage.

set point adjusting by push buttons or by modbus communication

output y1, VAV 0...10 V < 2 mA

output y2, fan 0...10 V < 2 mA

output y3, cooling 0…10 V / 10...0 V < 2 mA

output y4, heating 0…10 V / 10...0 V < 2 mA

output A1, cooling 24 Vac < 1 A, thermal actuator

output A2, heating 24 Vac < 1 A, thermal actuator

ambient temperature 0…+50 °C

mounting with screws on wall or on a junction box

housing IP20

supply 24 Vac/dc, < 1 VA

nOte: Only the 0…10 V outputs and Modbus work

when using DC supply voltage.

set point adjusting by push buttons or by modbus communication

output y1, VAV 0...10 V < 2 mA

output y2, fan 0...10 V < 2 mA

output A1, cooling 24 Vac < 1 A, thermal actuator

output A2, heating 24 Vac < 1 A, thermal actuator

output B1, on/off damper 24 Vac < 0,5 A

output B2, light control 24 Vac < 0,5 A

ambient temperature 0…+50 °C

mounting with screws on wall or on a junction box

housing IP20

HLS 44 1150250 room temperature controller with Modbus communication

FCRY 3 1183070 fan coil relay

HLS 44-SER 1150251 configuration tool for HLS 44

HLS 44-v 1150260 room temperature controller for fan coil VAV and lights, Modbus communication

FCRY 3 1183070 fan coil relay

RYvA 16 1183060 relay for fluorescent lamps 230 V, 16 A

HLS 44-SER 1150251 configuration tool for HLS 44

teMPeRAtURe COntROLLeRS

teMPeRAtURe COntROLLeRS

room °C

room °C

6Type arT no.

Type arT no.

Page 24: Catálogo Produal 2013

PRODUAL l 24 l CAtALOgUe

PDS 2 is a temperature controller for air handling unit, hot domestic water and heating applications. the controller supports Pt1000 temperature sensors. the thermal actuators can be either 0...10 V controlled or 3-point controlled. Configuration, settings and monitoring can be made by using display and push buttons. the controller has RS-485 connection for Modbus RtU communication.

supply 24 Vac/dc < 2 VA

inputs 3 x Pt1000 or 2 x Pt1000 + 1 x potentiometer

1 x 0…10 V / digital

outputs 3 or 4 x 0…10 Vdc, 2 mA

4 x 24 Vac 1 A triac

housing IP20, for 35 mm DIn rail

dimensions 53 x 90 x 58 mm

teMPeRAtURe COntROLLeRS°C

PDS 2 1150120 controller

TEAT PT 1000 1174070 immersion water sensor

AT 80 1170010 pocket

TEHR PT 1000 1174190 room sensor IP20

TEK PT 1000 1174040 duct sensor IP54

TENA PT 1000 1174050 domestic water sensor

TEP PT 1000 1174080 pipe strap-on sensor

TEU PT 1000 1174090 outdoor sensor IP54

TEHR PT 1000-P/PDS 2 1174231 room sensor + set point for PDS 2, IP20

HLS 45 is a versatile room controller for individual room temperature and VAV control applications. HLS 45 is excellent for both 2-pipe FCU and floor heating and cooling applications.the controller has a galvanically isolated RS-485 connection for Modbus RtU communication.

supply 24 Vac/dc, < 1 VA

nOte: Only the 0…10 V outputs and Modbus work

when using DC supply voltage.

set point adjusting by push buttons or by modbus communication

outputs 0...10 V < 2 mA for VAV

0...10 V < 2 mA for fan

0…10 V < 2 mA for heating/cooling valve control

2 x 24 Vac < 1 A for thermal actuators or 3-point actuator

ambient temperature 0…+50 °C

mounting with screws on wall or on a junction box

housing IP20, ABS plastic

HLS 45 1150270 room temperature controller with Modbus communication

FCRY 3 1183070 fan coil relay

HLS 45-SER 1150271 configuration tool for HLS 45

teMPeRAtURe COntROLLeRSroom °C

6 Type arT no.

Type arT no.

Page 25: Catálogo Produal 2013

PRODUAL l 25 l CAtALOgUe

HS 2.2 is a universal controller designed for HVAC applications. It can be used for controlling e.g. pressure, differential pressure, temperature or illumination level. Display is possible to scale according to the measurement.

UnIVeRSAL COntROLLeRS °C, % rH, Pa, bar, CO, CO2, m/s, lux

supply 24 Vac/dc, < 1VA

nOte: Only the 0…10 V outputs work when using

DC supply voltage.

inputs 1 x 0…10 V, 10 kΩ

1 x DI, potential free

outputs 1 x 0…10 Vdc, 2 mA

1 x 0/10 Vdc

1 x 24 Vac, < 1 A, for thermal or 3-point actuators

housing IP20, ABS plastic

mounting with screws on wall or on a junction box

(hole distance 60 mm)

HS 2.2 1150240 universal controller, room housing

PDS 2.2 universal controller can be used for controlling e.g. pressure, humidity or temperature. the controller supports 0…10 V controlled, 3-point controlled or thermal actuators. Configuration, settings and monitoring can be made by using display and push buttons. the controller has RS-485 connection for Modbus RtU communication.

supply 24 Vac/dc, < 2 VA

inputs 0…10 V measurement

0…10 V external set point setting

outputs 1 x 0…10 Vdc, 2 mA

2 x 24 Vac, < 1 A, for thermal or 3-point actuators

1 x 10 Vdc, 2 mA, for 4,7...220 kΩ potentiometer

housing IP20, for 35 mm DIn rail

dimensions 53 x 90 x 58 mm

PDS 2.2 1150150 universal controller

UnIVeRSAL COntROLLeRS °C, % rH, Pa, bar, CO, CO2, m/s, lux

7

Type arT no.

Type arT no.

Page 26: Catálogo Produal 2013

PRODUAL l 26 l CAtALOgUe

Page 27: Catálogo Produal 2013

PRODUAL l 27 l CAtALOgUe

teAt immersion water temperature sensors are designed for detecting heating and cooling water temperatures. Sensor is always installed to a pocket.

mounting R ½” (Produal pocket)

range -50…+120 °C

time constant 5 s

housing IP54, stem or cable gland downwards

cable gland M16

pressure rating Pn16 (Produal pocket)

materials PBt, PC, PA, acid proof steel

mounting depth 80 mm

several other mounting depths also available

for example 300 mm (e.g. teAt Pt 1000-300)

HeAtIng/COOLIng WAteR SenSORS

°C

TEAT PT 100 1173070 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEAT PT 1000 1174070 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEAT NTC 1.8 117e070 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEAT NTC 2.2 1172070 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEAT NTC 10 1175070 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEAT NTC 10-KB 117B070 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEAT NTC 10-AN 117H070 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEAT NTC 10-C 117M070 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEAT NTC 20 1176070 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEAT NI 1000-LG 1178070 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEAT NI 1000 117C070 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEAT KP 10 117J070 LM335Z, 10 mV/K, 2,98 V / 25 °C

TEAT LL 1177070 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEAT LU 1179070 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TE-N 1170130 display option for LL and LU transmitters

poCKeTS

AT 80 1170010 pocket, stainless steel (AISI 303), Ø 8 mm x 90 mm

ATM 80 1170030 pocket, brass (Ms 362), Ø 8mm x 90mm

ATH 80 1170020 pocket, acid proof steel (AISI 316L), Ø 8 mm x 90 mm

ATS 80 1170025 pocket, acid proof steel (AISI 316ti), sea water resistant, Ø 8 mm x 90 mm

ATH 300 1170021 pocket, acid proof steel (AISI 316L), Ø 8 mm x 310 mm

Type arT no.

8

Page 28: Catálogo Produal 2013

PRODUAL l 28 l CAtALOgUe

tenA sensors are designed for detecting hot domestic water temperatures with fast response.

mounting R ½”

range -50…+120 °C

time constant 2,5 s

housing IP54, stem or cable gland downwards

cable gland M16

pressure rating Pn16

materials PBt, PC, PA, stainless steel

mounting depth 80 mm

50 mm (e.g. tenA ntC 10-50)

210 mm (e.g. tenA ntC 10-210)

HOt DOMeStIC WAteR SenSORS°C

TENA PT 100 1173050 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TENA PT 100-50 1173051 like sensor above, stem length 50 mm

TENA PT 1000 1174050 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TENA PT 1000-50 1174051 like sensor above, stem length 50 mm

TENA NTC 1.8 117e050 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TENA NTC 1.8-50 117e051 like sensor above, stem length 50 mm

TENA NTC 2.2 1172050 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TENA NTC 2.2-50 1172051 like sensor above, stem length 50 mm

TENA NTC 10 1175050 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TENA NTC 10-50 1175051 like sensor above, stem length 50 mm

TENA NTC 10-KB 117B050 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TENA NTC 10-KB-50 117B051 like sensor above, stem length 50 mm

TENA NTC 10-AN 117H050 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TENA NTC 10-AN-50 117H051 like sensor above, stem length 50 mm

TENA NTC 10-C 117M050 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TENA NTC 10-C-50 117M051 like sensor above, stem length 50 mm

TENA NTC 20 1176050 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TENA NTC 20-50 1176051 like sensor above, stem length 50 mm

TENA NI 1000-LG 1178050 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TENA NI 1000-LG-50 1178051 like sensor above, stem length 50 mm

TENA NI 1000 117C050 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TENA NI 1000-50 117C051 like sensor above, stem length 50 mm

TENA LL 1177050 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5°C

TENA LL-50 1177051 like sensor above, stem length 50 mm

TENA LU 1179050 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5°C

TENA LU-50 1179051 like sensor above, stem length 50 mm

TE-N 1170130 display option for LL and LU transmitters

8

Type arT no.

Page 29: Catálogo Produal 2013

PRODUAL l 29 l CAtALOgUe

8

teV sensors are designed for frost protection and for applications with fast response.

mounting R ¼”

range -50…+120 °C

time constant 2,5 s

cable 2 m LIyy 2 x 0,14

materials acid proof steel

pipe connector brass

pressure rating Pn16

mounting depth < 200 mm (also available < 400 mm)

FROSt gUARD SenSORS°C

Type arT no.

TEv PT 100 1173020 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEv PT 1000 1174020 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEv NTC 1.8 117e020 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEv NTC 2.2 1172020 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEv NTC 10 1175020 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEv NTC 10-KB 117B020 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEv NTC 10-AN 117H020 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEv NTC 10-C 117M020 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEv NTC 20 1176020 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEv NI 1000-LG 1178020 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEv NI 1000 117C020 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEv LL 1177020 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEv LU 1179020 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

teKV sensors are designed for frost protection and for applications with fast response.

mounting R ¼”

range -50…+120 °C

time constant 2,5 s

housing IP54, stem or cable gland downwards

cable gland M16

materials PBt, PC, PA, acid proof steel

pipe connector brass

mounting depth < 200 mm (also available < 400 mm)

FROSt gUARD SenSORS°C

Type arT no.

TEKv PT 100 1173120 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEKv PT 1000 1174120 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEKv NTC 1.8 117e120 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEKv NTC 2.2 1172120 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEKv NTC 10 1175120 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEKv NTC 10-KB 117B120 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEKv NTC 10-AN 117H120 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEKv NTC 10-C 117M120 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEKv NTC 20 1176120 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEKv NI 1000-LG 1178120 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEKv NI 1000 117C120 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEKv LL 1177120 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEKv LU 1179120 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TE-N 1170130 display option for LL and LU transmitters

Page 30: Catálogo Produal 2013

PRODUAL l 30 l CAtALOgUe

teP sensors are designed for pipe strap-on installations in heating and cooling applications.

mounting by a band on the pipe (diam.< 90 mm)

range -50…+120 °C

time constant approx. 5 s

housing IP54, stem or cable gland downwards

cable gland M16

materials PBt, PC, PA, zink casting

StRAP-On SenSORS°C

Type arT no.

TEP PT 100 1173080 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEP PT 1000 1174080 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEP NTC 1.8 117e080 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEP NTC 2.2 1172080 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEP NTC 10 1175080 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEP NTC 10-KB 117B080 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEP NTC 10-AN 117H080 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEP NTC 10-C 117M080 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEP NTC 20 1176080 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEP NI 1000-LG 1178080 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEP NI 1000 117C080 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEP KP 10 117J080 LM335Z, 10 mV/K, 2,98 V / 25 °C

TEP LL 1177080 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEP LU 1179080 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TE-N 1170130 display option for LL and LU transmitters

8

tePK sensors are designed for pipe strap-on installations in heating and cooling applications.

mounting by a band on the pipe (Ø10...100 mm)

range -20…+80 °C

time constant about 5 s

material zinc casting

cable 2 m (LIyy 2 x 0,14) PVC cable

StRAP-On SenSORS°C

Type arT no.

TEPK PT 100 1173240 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEPK PT 1000 1174240 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEPK NTC 1.8 117e240 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEPK NTC 2.2 1172240 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEPK NTC 10 1175240 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEPK NTC 10-KB 117B240 5025 kΩ / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEPK NTC 10-AN 117H240 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEPK NTC 10-C 117M240 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEPK NTC 20 1176240 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEPK NI 1000-LG 1178240 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEPK NI 1000 117C240 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEPK LL 1177240 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEPK LU 1179240 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

Page 31: Catálogo Produal 2013

PRODUAL l 31 l CAtALOgUe

8

teK sensors are designed for detecting temperatures inside ventilation ducts.

mounting with flange, adjustable < 200 mm

range -50…+70 °C

housing IP54, stem or cable downwards

cable gland M16

materials PBt, PC, PA, stainless steel

DUCt SenSORS°C

TEK PT 100 1173040 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEK PT 1000 1174040 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEK NTC 1.8 117e040 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEK NTC 2.2 1172040 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEK NTC 10 1175040 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEK NTC 10-KB 117B040 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEK NTC 10-AN 117H040 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEK NTC 10-C 117M040 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEK NTC 20 1176040 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEK NI 1000-LG 1178040 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEK NI 1000 117C040 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEK KP 10 117J040 LM335Z, 10 mV/K, 2,98 V / 25 °C

TEK LL 1177040 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEK LU 1179040 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TE-N 1170130 display option for LL and LU transmitters

Type arT no.

teKHA sensors are designed for detecting temperatures inside small ventilation ducts.

mounting with flange, adjustable < 100 mm

range -50…+70 °C

stem Ø6 mm x 100 mm, acid proof steel

cable 2 m (LIyy 2 x 0,14) PVC cable

other lengths to order

DUCt SenSORS°C

Type arT no.

TEKHA PT 100 1173290 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEKHA PT 1000 1174290 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEKHA NTC 1.8 117e290 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEKHA NTC 2.2 1172290 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEKHA NTC 10 1175290 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEKHA NTC 10-AN 117H290 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEKHA NTC 10-C 117M290 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEKHA NTC 20 1176290 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEKHA NI 1000-LG 1178290 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEKHA NI 1000 117C290 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEKHA KP 10 117J290 LM335Z, 10 mV/K, 2,98 V / 25 °C

Page 32: Catálogo Produal 2013

PRODUAL l 32 l CAtALOgUe

teKA sensors are designed for detecting temperatures inside large ducts. Sensor’s mechanical construction ensures accurate average temperature measurement.

mounting with flange and springs

range -50…+70 °C

length 3 m

housing IP54, stem or cable downwards

cable gland M16

materials PBt, PC, PA, stainless steel

DUCt SenSORS°C

Type arT no.

TEKA PT 100 1173130 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEKA PT 1000 1174130 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEKA NTC 1.8 117e130 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEKA NTC 2.2 1172130 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEKA NTC 10 1175130 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEKA NTC 10-KB 117B130 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEKA NTC 10-AN 117H130 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEKA NTC 10-C 117M130 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEKA NTC 20 1176130 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEKA NI 1000-LG 1178130 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEKA NI 1000 117C130 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEKA LL 1177130 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEKA LU 1179130 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TE-N 1170130 display option for LL and LU transmitters

8

Page 33: Catálogo Produal 2013

PRODUAL l 33 l CAtALOgUe

8

teKA-500 sensors are designed for detecting temperatures inside ventilation ducts. Sensor detects the average temperature with 4 sensor elements.

mounting with flange

range -50…+70 °C

stem length 500 mm

housing IP54, stem or cable downwards

cable gland M16

materials PBt, PC, PA, stainless steel

DUCt SenSORS°C

Type arT no.

TEKA PT 100-500 1173170 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEKA PT 1000-500 1174170 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEKA NTC 1.8-500 117e170 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEKA NTC 2.2-500 1172170 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEKA NTC 10-500 1175170 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEKA NTC 10-KB-500 117B170 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEKA NTC 10-AN-500 117H170 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEKA NTC 10-C-500 117M170 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEKA NTC 20-500 1176170 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEKA NI 1000-LG-500 1178170 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEKA NI 1000-500 117C170 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEKA LL-500 1177170 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEKA LU-500 1179170 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TE-N 1170130 display option for LL and LU transmitters

Page 34: Catálogo Produal 2013

PRODUAL l 34 l CAtALOgUe

teKy4 temperature sensors are designed for detecting temperatures in automatic HVAC systems. the rolled stainless steel sleeve provides good protection against water and dust.

range -30…+80 °C

cable Ø 3.2 mm x 2.3 m, PVC

other lengths also available

sleeve Ø 4 mm x 30 mm, stainless steel

protection class IP67

CABLe teMPeRAtURe SenSORS°C

Type arT no.

TEKY4 PT 100 1173330 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEKY4 PT 1000 1174330 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEKY4 NTC 1.8 117e330 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEKY4 NTC 2.2 1172330 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEKY4 NTC 10 1175330 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEKY4 NTC 10-KB 117B330 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEKY4 NTC 10-AN 117H330 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEKY4 NTC 10-C 117M330 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEKY4 NTC 20 1176330 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEKY4 NI 1000-LG 1178330 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEKY4 NI 1000 117C330 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEKY4 LL 1177330 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEKY4 LU 1179330 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C8

Page 35: Catálogo Produal 2013

PRODUAL l 35 l CAtALOgUe

teKy6 and teKy6S temperature sensors are designed for detecting temperatures in automatic HVAC systems. the rolled stainless steel sleeve provides good protection against water and dust.

teKy6: range -30…+80 °C

cable Ø 5 mm x *2.3 m, PVC

teKy6S: range -50…+150 °C

cable Ø 5 mm x *2.3 m, silicone

sleeve Ø 6 mm x 45 mm, stainless steel

protection class IP67

* other lengths also available

CABLe teMPeRAtURe SenSORS°C

Type arT no.

TEKY6 PT 100 1173320 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEKY6 PT 1000 1174320 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEKY6 NTC 1.8 117e320 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEKY6 NTC 2.2 1172320 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEKY6 NTC 10 1175320 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEKY6 NTC 10-KB 117B320 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEKY6 NTC 10-AN 117H320 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEKY6 NTC 10-C 117M320 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEKY6 NTC 20 1176320 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEKY6 NI 1000-LG 1178320 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEKY6 NI 1000 117C320 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEKY6 KP 10 117J320 LM335Z, 10 mV/K, 2,98 V / 25 °C

TEKY6 LL 1177320 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEKY6 LU 1179320 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TEKY6S PT 100 1173340 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEKY6S PT 1000 1174340 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEKY6S NTC 10 1175340 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEKY6S NI 1000-LG 1178340 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEKY6S NI 1000 117C340 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEKY6S LL 1177340 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEKY6S LU 1179340 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

8

Page 36: Catálogo Produal 2013

PRODUAL l 36 l CAtALOgUe

teL sensors are designed for detecting floor temperatures. the sensor is installed in the cable duct inside the floor construction.

range -30…+70 °C

cable 3 m (LIyy 2 x 0,5) PVC cable

other lengths also available

sleeve Ø 7 mm

CABLe teMPeRAtURe SenSORS, FLOOR

°C

Type arT no.

TEL PT 100 1173280 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEL PT 1000 1174280 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEL NTC 1.8 117e280 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEL NTC 2.2 1172280 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEL NTC 10 1175280 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEL NTC 10-AN 117H280 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEL NTC 10-C 117M280 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEL NTC 20 1176280 0 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEL NI 1000-LG 1178280 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEL NI 1000 117C280 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEL KP 10 117J280 LM335Z, 10 mV/K, 2,98 V / 25 °C

teM sensors are designed for detecting temperatures in road ramps and street constructions. the sensor must be installed in a cable duct.

range -30…+80 °C

cable 5 m (PUR 2 x 0,75)

other lengths also available

sleeve Ø 9 mm

CABLe teMPeRAtURe SenSORS, SOIL InStALLAtIOn

°C

Type arT no.

TEM PT 100 1173310 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEM PT 1000 1174310 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEM NTC 1.8 117e310 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEM NTC 2.2 1172310 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEM NTC 10 1175310 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEM NTC 10-AN 117H310 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEM NTC 10-C 117M310 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEM NTC 20 1176310 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEM NI 1000-LG 1178310 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEM NI 1000 117C310 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEM KP 10 117J310 LM335Z, 10 mV/K, 2,98 V / 25 °C

8

Page 37: Catálogo Produal 2013

PRODUAL l 37 l CAtALOgUe

teSK sensors are designed for detecting combustion gas temperatures.

teHR sensors are designed for detecting room temperatures.

mounting R ½” or with flange on order

range 0…+400 °C

housing silumin cast, IP54, stem or cable gland downwards

cable gland Pg16

pressure rating Pn16

mounting with screws on wall

or on a junction box (hole distance 60 mm)

range 0...+50 °C

housing IP20, ABS plastic

options push button, 5-position switch, LeD-lamp, display

COMBUStIOn gAS SenSORS

ROOM teMPeRAtURe SenSORS

°C

°C

Type arT no.

Type arT no.

TESK PT 100 1173160 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TESK PT 1000 1174160 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TESK LL 0/400 1177160 2-wire transmitter, supply 22...35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TESK LU 0/400 1179160 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TEHR PT 100 1173190 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEHR PT 1000 1174190 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEHR NTC 1.8 117e190 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEHR NTC 2.2 1172190 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEHR NTC 10 1175190 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEHR NTC 10-KB 117B190 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEHR NTC 10-AN 117H190 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEHR NTC 10-C 117M190 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEHR NTC 20 1176190 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEHR NI 1000-LG 1178190 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEHR NI 1000 117C190 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEHR KP 10 117J190 LM335Z, 10 mV/K, 2,98 V / 25 °C

opTionS:

TEHR-S 1170080 push button (no / nc) 24 Vac/dc

TEHR-S5 1170090 5-position switch (1, 2 ,3, 0, A) 24 Vac/dc

TEHR-L 1170100 LeD 24 V

TEHR-N 1171140 digital display, input 0…10 V=0…50 °C

8

Page 38: Catálogo Produal 2013

PRODUAL l 38 l CAtALOgUe

teHR-P sensors are designed for detecting room temperatures and setting the set point to the controller.

mounting with screws on wall or on a junction box

(hole distance 60 mm)

range 0...+50 °C

potentiometer to order

resistors to order

housing IP20, ABS plastic

options push button, 5-position switch, LeD lamp, display

ROOM teMPeRAtURe SenSORS°C + set point setting

Type arT no.

TEHR PT 100-P 1173230 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEHR PT 1000-P 1174230 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEHR NTC 1.8-P 117e230 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEHR NTC 2.2-P 1172230 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEHR NTC 10-P 1175230 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEHR NTC 10-AN-P 117H230 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEHR NTC 10-C-P 117M230 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEHR NTC 20-P 1176230 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEHR NI 1000-LG-P 1178230 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEHR NI 1000-P 117C230 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEHR KP 10-P 117J230 LM335Z, 10 mV/K, 2,98 V / 25 °C

opTionS:

TEHR-S 1170080 push button (no / nc) 24 Vac/dc

TEHR-S5 1170090 5-position switch (1, 2, 3, 0, A) 24 Vac/dc

TEHR-L 1170100 LeD 24 V

TEHR-N 1170140 digital display, input 0…10 V=0…50 °C

teHR LL (2-wire, 4…20 mA) and teHR LU (3-wire, 0…10 V) are temperature transmitters for dry room spaces. the output range is selectable. the teHR-M output is available as a 0...10 V signal and via Modbus.

mounting with screws on wall or on a junction box (hole distance 60 mm)

range 0...+50 °C

sensor Pt1000 en 60751/B

accuracy ±0,5 °C / 0 °C

potentiometer to order

housing IP20, ABS plastic

ROOM teMPeRAtURe SenSORS°C

Type arT no.

TEHR LL 1177190 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA

TEHR LL-N 1177191 with display

TEHR LL-P 1177230 2-wire transmitter, supply 22…35 Vdc, output 4…20 mA, potentiometer

TEHR LL-N-P 1177231 with display, potentiometer

TEHR LU 1179190 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA

TEHR LU-N 1179191 with display

TEHR LU-P 1179230 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, potentiometer

TEHR LU-N-P 1179231 with display, potentiometer

TEHR-M 1170600 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, Modbus RtU

TEHR-M-N 1170601 with display, Modbus RtU

8

Page 39: Catálogo Produal 2013

PRODUAL l 39 l CAtALOgUe

teHU sensors are designed for detecting room temperatures. Flush mounting.

teU sensors are designed for detecting outdoor temperatures.

mounting on a junction box

range 0...+50 °C

housing IP20, ABS plastic

mounting with screws on wall, external lugs

range -50…+50 °C

housing IP54, cable gland downwards

cable gland M16

materials PBt, PC, PA

ROOM teMPeRAtURe SenSORS

OUtDOOR teMPeRAtURe SenSORS

°C

°C

Type arT no.

Type arT no.

TEHU PT 100 1173150 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C en 60751/B

TEHU PT 1000 1174150 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEHU NTC 1.8 117e150 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEHU NTC 2.2 1172150 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEHU NTC 10 1175150 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEHU NTC 10-KB 117B150 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEHU NTC 10-AN 117H150 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEHU NTC 10-C 117M150 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEHU NTC 20 1176150 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEHU NI 1000-LG 1178150 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEHU NI 1000 117C150 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEHU KP 10 117J150 LM335Z, 10 mV/K, 2,98 V / 25 °C

TEU PT 100 1173090 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TEU PT 1000 1174090 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TEU NTC 1.8 117e090 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TEU NTC 2.2 1172090 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TEU NTC 10 1175090 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TEU NTC 10-KB 117B090 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TEU NTC 10-AN 117H090 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TEU NTC 10-C 117M090 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TEU NTC 20 1176090 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TEU NI 1000-LG 1178090 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TEU NI 1000 117C090 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TEU KP 10 117J090 LM335Z, 10 mV/K, 2,98 V / 25 °C

8

Page 40: Catálogo Produal 2013

PRODUAL l 40 l CAtALOgUe

teU transmitters are designed for detecting outdoor temperatures.

mounting with screws on wall, external lugs

ranges -50…+50, -50…+150, 0…+50, 0…+100 °C

housing IP54, cable gland downwards

cable gland M16

materials PBt, PC, PA

OUtDOOR teMP SenSORS

Type arT no.

TEU LL 1177090 2-wire transmitter, supply 22...35 Vdc, output 4…20 mA, accuracy ±0,5 °C

TEU LU 1179090 3-wire transmitter, supply 24 Vac/dc, output 0…10 V < 2 mA, accuracy ±0,5 °C

TEU-N 1170131 display option for teU LL and teU LU transmitters

teS sensors are designed for detecting temperatures in dusty, hot and wet (industrial) spaces.

teSIM sensor simulators are designed for simulating temperature sensor when testing a control system.

mounting with screws on wall

range -50…+120 °C

housing silumin cast IP67, cable gland downwards

cable gland Pg11

ranges 5 selectable temperature values

cable with banana jacks

accuracy, Pt1000 ±0,15°C / 0 °C

accuracy, ntC 10 ±0,25°C / 25 °C

housing IP54

InDUStRIAL teMP SenSORS

teMPeRAtURe SenSOR SIMULAtOR

IP 67, °C

Type arT no.

Type arT no.

TES PT 100 1173100 100 Ω / 0 °C, accuracy ±0,3 °C / 0 °C, en 60751/B

TES PT 1000 1174100 1000 Ω / 0 °C, accuracy ±0,3 °C / 0 °C (Honeywell, Danfoss equivalent)

TES NTC 1.8 117e100 1800 Ω / 25 °C, accuracy ±0,3 °C / 25 °C (tAC equivalent)

TES NTC 2.2 1172100 2252 Ω / 25 °C, accuracy ±0,25 °C / 25 °C (Johnson equivalent)

TES NTC 10 1175100 10 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (trend equivalent)

TES NTC 10-KB 117B100 5025 Ω / 25 °C, accuracy ±0,5 °C / 25 °C (Satchwell equivalent)

TES NTC 10-AN 117H100 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Andover equivalent)

TES NTC 10-C 117M100 10 kΩ / 25 °C, accuracy ±0,25 °C / 25 °C (Carel equivalent)

TES NTC 20 1176100 20 kΩ / 25 °C, accuracy ±0,2 °C / 25 °C (Honeywell equivalent)

TES NI 1000-LG 1178100 1000 Ω / 0 °C, accuracy ±0,5 °C / 0 °C (Siemens equivalent)

TES NI 1000 117C100 1000 Ω / 0 °C, accuracy ±0,4 °C / 0 °C (Sauter equivalent)

TES KP 10 117J100 LM335Z, 10 mV/K, 2,98 V / 25 °C

TESIM PT 1000 1170220 Pt1000 simulator

TESIM NTC 10 1170230 ntC 10 simulator

°C

8

Page 41: Catálogo Produal 2013

PRODUAL l 41 l CAtALOgUe

LLK and LUK are transmitters for temperature measuring. LLK is a 2-wire transmitter converting the sensor resistance to the 4…20 mA signal. LUK is a 3-wire transmitter converting the sensor signal to the 0…10 V signal. the transmitter needs a separatePt1000 sensor.

LLK: supply 22…35 Vdc

output 4…20 mA

LUK: supply 24 Vac/dc < 1 VA

output 0…10 Vdc < 2mA

range selectable

housing IP54

dimensions 115 x 115 x 45 mm

teMPeRAtURe tRAnSMItteRS °C

Type arT no.

LLK 1182190 2-wire transmitter

LLK-N 1182191 2-wire transmitter with display

LUK 1182200 3-wire transmitter

LUK-N 1182201 3-wire transmitter with display

KO IVS is a protective casing for room sensors in spaces like sports halls.Casing is transparent and with a lock.

PROteCtIVe CASIng FOR ROOM SenSOR

Type arT no.

KO IvS KO5239 protective casing for room sensors

8

the casings of room sensors can be delivered painted with special desired colours blending perfectly in the colours of the space.

CASIngS

Page 42: Catálogo Produal 2013

PRODUAL l 42 l CAtALOgUe

ISO 10 provides galvanic isolation between input and output signals and supply. Signal can also be converted, e.g. a 0…10 V signal into a 4…20 mA signal.

supply 24 Vac/dc

input 0…1 V, 0…10 V, 2…10 V, 0…20 mA or 4…20 mA

output 0…10 V, 2…10 V < 2 mA, 0…20 mA or

4…20 mA < 500 Ω

input impedance at …10 V range < 250 kΩ (I ≤ 50 uA)

input impedance at …20 mA range 100 Ω

isolation voltage < 500 Vdc

ambient temperature -20…+50 °C

housing IP20, for 35 mm DIn rail

dimensions 13 x 111 x 89 mm

tRAnSDUCeRS

Type arT no.

ISO 10 1182060 signal isolator

signal isolator

MIO 12 is an I/O module with a Modbus communication, reading four Pt1000 or digital inputs (MIO 12-Pt) or four 0...10 V or digital inputs (MIO 12-V). Outputs for thermal actuators or two 3-point actuators and also for four 0...10 V signals are available.

DA 6 converts 1...6 digital (contact) inputs into one analogue 0...10 V or 4...20 mA output. the state of each contact can be identified by the control system software.

supply 24 Vac/dc

MIO 12-Pt: inputs 4 x Pt1000 or 4 x potential free digital input

MIO 12-V: inputs 4 x analogue input or 4 x potential free digital input

outputs 4 x 0...10 Vdc, 2 mA; 4 x 24 Vac 1A,

for thermal actuator or two 3-point controller

housing IP20, for 35 mm DIn rail

dimensions 53 x 90 x 58 mm

supply 24 Vac, 1 VA

inputs 1...6 potential free contact inputs

output 1 0...10 Vdc < 10 mA

output 2 4...20 mA

housing IP20, for 35 mm DIn rail

dimensions 68 x 90 x 68 mm

I/O MODULeS

tRAnSDUCeRS

Type arT no.

Type arT no.

MIO 12-PT 1181300 Modbus I/O, 4 analogue inputs (Pt1000 or DI, potential free)

MIO 12-v 1181310 Modbus I/O, 4 analogue inputs (0…10 V)

DA 6 1182040 DI/AO converter

9

Page 43: Catálogo Produal 2013

PRODUAL l 43 l CAtALOgUe

Jy is a switch mode power supply converting a 24 Vac/dc supply into a lower DC voltage supply. electronic protection for overloading.

PMU 3 converts a 0…10 Vdc signal into a 24 Vac 3-point control signal.

supply 24 Vac/dc

output by coding 10 Vdc, 12 Vdc, 16 Vdc, 18 Vdc,

24 Vdc (only with 24 Vac supply),

ADJ = adjustable 3.6…24 V

loading 1 A

protection electronic overload protection

housing IP20, for 35 mm DIn rail

dimensions 45 x 90 x 58 mm

supply 24 Vac, 1 VA

input 0…10 Vdc < 1 mA

output 24 Vac < 2 A for a 3-point actuator

actuator running time adjustable, 15…240 s

housing IP20, 11-pole relay housing

tRAnSDUCeRS

tRAnSDUCeRS

24 vac/dc 3.6…24 vdc

0…10 v 3-point control

Type arT no.

Type arT no.

JY 1184020 AC/DC to DC converter

PMU 3 1182120 from 0…10 V to 3-point converter

UMP 3 converts a 3-point control signal into a 0…10 Vdc signal.

supply 24 Vac, 1 VA

input 10…40 Vac/dc

output 0…10 Vdc, < 1 mA

output change speed adjustable, 15…240 s

housing IP20, 11-pole relay housing

tRAnSDUCeRS3-point control 0…10 vdc

Type arT no.

UMP 3 1182150 from 3-point to 0...10 V converter

9

Page 44: Catálogo Produal 2013

PRODUAL l 44 l CAtALOgUe

UV 10 is an amplifier for 0…10 V signals. UV 10 can also be used for controlling fluorescent lamps with electronic transformers.

supply 24 Vac/dc < 0,5 VA

input 0(2)…10 Vdc < 0,5 mA

output 0(2)…10 Vdc < 20 mA,

or inverted (10…0 Vdc)

housing IP20, for 35 mm DIn rail

dimensions 23 x 77 x 45 mm

tRAnSDUCeRS

Type arT no.

Uv 10 1182160 signal amplifier

0…10 v 0…10 v (10…0 v)

PyR 4 converts one 0...10 Vdc signal into two 0…10 V or 10…0 V signals. Output can be restricted with a set point potentiometer if required.

AO 2 and AO 3 are signal converters designed for HVAC applications. the converters divide one 0…10 V signal to two (AO 2) or three (AO 3) 0…10 V signals.

supply 24 Vac 2 VA

input 0…10 Vdc

set point 0…100 % (for restriction)

outputs 0…10 Vdc < 10 mA, (direct and inverted)

housing IP20, 11-pole relay housing

supply 24 Vac/dc, 0,5 VA

input 0...10 Vdc, < 0,2 mA

outputs AO2 0...10 Vdc, 2 mA

y1 0…10 V if In = 0 - 5 …10 V

y2 0…10 V if In = 5…10 V

outputs AO3 0...10 Vdc, 2 mA

y1 0…10 V if In = 0 - 3,3 …10 V

y2 0…10 V if In = 3,3 - 6,6…10 V

y3 0…10 V if In = 6,6…10 V

housing IP20, for 35 mm DIn rail

dimensions 23 x 77 x 41 mm

tRAnSDUCeRS

tRAnSDUCeRS

0…10 vdc 2 x 0…10 vdc with restriction

0…10 vdc 2 x 0…10 vdc / 3 x 0…10 vdc

Type arT no.

Type arT no.

PYR 4 1182130 2-step / limit unit

AO 2 1182220 signal divider, 2 outputs

AO 3 1182210 signal divider, 3 outputs

9

Page 45: Catálogo Produal 2013

PRODUAL l 45 l CAtALOgUe

M230/24-15 transforms 230 Vac supply to 24 Vac 15 VA supply.

M230/24-30 transforms 230 Vac supply to 24 Vac 30 VA supply.

M230/12-4 transforms 230 Vac supply to 12 Vdc 4 VA supply.

supply 230 Vac, 15 VA

output 1 24 Vac 15 VA

housing IP20, for 35 mm DIn rail

dimensions 35 x 90 x 60 mm

supply 230 Vac, 30 VA

output 24 Vac 1,25 A, fuse protected

housing IP00

dimensions 90 x 90 x 68 mm

supply 230 Vac, 4 VA

output 12 Vdc 0,25 A

housing IP20

tRAnSFORMeRS

tRAnSFORMeRS

tRAnSFORMeRS

230 vac 24 vac, 15 vA

230 vac 24 vac, 30 vA

230 vac 12 vdc, 4 vA

Type arT no.

Type arT no.

Type arT no.

M230/24-15 1184090 transformer

M230/24-30 1184050 transformer

M230/12-4 1184080 power supply

9

Page 46: Catálogo Produal 2013

PRODUAL l 46 l CAtALOgUe

LA 14 is an occupancy sensor for controlling ventilation and lighting. Intelligent, processor based, logic prevents false functions being at the same time very sensible. Relay function is quiet and the release delay is adjustable.

supply 24 Vac/dc, 15…30 Vac/dc < 0,5 W

angle 120°

housing IP20, white plastic

mounting flush (surface mounting casing optional)

settings:

function modes movement detector/occupancy sensor *

relay contact nC*/nO, < 100 mA, 24 Vac/60 Vdc

delay selectable 2 s, 2 min, 10 min tai 20 min*

* Factory settings

OCCUPAnCy SenSORS

Type arT no.

LA 14 1185050 occupancy sensor

KO PRA KO3602 casing for surface mounting

LA 15 is designed for controlling lighting. Up to 1,5 A continuous fluorescent lighting load is allowed.

supply 24 Vac/dc, 20...28 Vac/dc

angle 120°

housing IP20, white plastic

mounting flush (surface mounting casing optional)

settings:

function modes movement detector*/occupancy sensor

signal relay RE1:

contact nC*/nO, < 100 mA, 24 Vac/60 Vdc

delay 2 s

lighting relay RE2:

contact 230 Vac 1,5 A

delay selectable 2 s, 2 min, 10 min or 20 min*

* Factory settings

OCCUPAnCy SenSORS

Type arT no.

LA 15 1185060 movement / occupancy sensor for switching lighting on/off

LA-RAJ 1185070 180° area guard for occupancy sensor

KO PRA KO3602 casing for surface mounting

9

Page 47: Catálogo Produal 2013

PRODUAL l 47 l CAtALOgUe

PLt 24 is a detector for monitoring occupancy through body heat and movements. the passive infrared PIR detector reacts to temperature changes in the range of the detection beams.Mounting bracket and screws are included to the delivery.

PLt 12 is a detector for monitoring occupancy through body heat and movements. the detector is passive infrared (PIR) which reacts to temperature changes in range of the detection beams. Mounting bracket and screws are included to the delivery.

supply 24 Vac/dc

alarm output nC*/nO, < 100 mA, 24 Vac/60 Vdc

function modes movement detection*/occupancy detection

ambient temperature -10...+45 °C

housing IP20

delay selectable 2 s*, 2 min, 10 min or 20 min

angle 140°, max. 12 m

* Factory settings

supply 12 Vdc

alarm output nC, < 500 mA, 24 Vdc

ambient temperature -10...+40 °C

housing IP20

angle 140°, max. 12 m

PIR DeteCtORS

PIR DeteCtORS

Type arT no.

PLT 24 1185040 PIR movement detector

PLT 24-K 1185045 PIR movement detector, ceiling mounting

PLT 12 1185080 PIR movement detector

9

Type arT no.

Page 48: Catálogo Produal 2013

PRODUAL l 48 l CAtALOgUe

LAP timers are designed for extending plant operating hours by pushing a button. the selected time is indicated by an indicator light.

supply 24 Vac or 230 Vac, 2 VA

range LAP 1 12, 24, 36, 48 or 60 minutes

range LAP 5 1, 2, 3, 4 or 5 hours

range LAP 10 2, 4, 6, 8 or 10 hours

output change over contact 230 Vac, 8 A. res.

time measurement accuracy ±10 s/h

housing IP20

mounting on a junction box or on the wall surface,

surface mounting casing included

tIMeRS

Type arT no.

LAP 1 1185025 12…60 minutes (max. time can be restricted to 12…36 minutes)

LAP 5 1185020 1…5 hours (max. time can be restricted to 1…3 hours)

LAP 10 1185021 2…10 hours (max. time can be restricted to 2…6 hours)

LAP 5-T 1185026 as LAP 5, but with a fan On/OFF indication

LAP 10-T 1185028 as LAP 10, but with a fan On/OFF indication

PJP is a low voltage push button device with 1, 2 or 4 buttons and indicator lights.

push button contact < 42 Vac, < 60 Vdc, < 0,8 A

indicator lights green, externally controlled

housing IP20

mounting on a junction box, surface mounting casing not included

LOW VOLtAge PUSH BUttOnS

PJP 1 1185030 1 push button and 1 indicator light

PJP 2 1185031 2 push buttons and 2 indicator lights

PJP 4 1185032 4 push buttons and 4 indicator lights

KO PRA KO3602 casing for surface mounting

9

Type arT no.

Page 49: Catálogo Produal 2013

PRODUAL l 49 l CAtALOgUe

LeKA 24 is an indicator light device with green and red light.

Ry 1 and AR 1 are relays with a 24 Vac/dc coil voltage. RyVA 16 can be used for lighting control because it withstands a short-term inrush current peak.

input 24 Vac/dc, 0,5 VA

output, led 1 red

output, led 2 green

housing IP20

mounting on a junction box, surface mounting casing not included

input 24 Vac/dc, 0,5 VA

output 230 Vac, 10 A res.

housing IP20, for 35 mm DIn rail

InDICAtOR LIgHtS

ReLAyS

24 vac/dc

coil 24 vac/dc

Type arT no.

Type arT no.

LEKA 24 1185090 indicator light

KO PRA KO3602 casing for surface mounting

AR 1 1183010 relay with normally open (nO) contact, width 13 mm

RY 1 1183020 relay with change-over contact, width 23 mm

RY 1-K 1183021 relay with change-over contact, socket connection at the output

RY 1-KK 1183030 relay with change-over contact and manual switch (On-OFF-A)

RYvA 16 1183060 relay for fluorescent lamps, 16 A (inrush current < 80 A, < 2,5 ms)

Ry 1-U and RyV 16-U are voltage controlled relays with 0…10 V input. RyV 16-U can be used for lighting control because it withstands a short-term inrush current peak.

supply 24 Vac/dc, 1 VA

input 0…10 Vdc < 0,2 mA

output change-over contact 230 Vac, 10 A res.

setpoint adjustable, 0…10 V

hysteresis adjustable 0,2…1,0 V

housing IP20, for 35 mm DIn rail

dimensions 23 x 77 x 41 mm

ReLAySinput 0...10 vdc

Type arT no.

RY 1-U 1183040 voltage controlled relay

RY 1-U-K 1183041 voltage controlled relay, socket connection at the output

RYv 16-U 1183050 voltage controlled relay, 16 A (inrush current < 80 A, < 2,5 ms)

9

Page 50: Catálogo Produal 2013

PRODUAL l 50 l CAtALOgUe

3-speed relay units for controlling fan coils (fan speed). FCRy 3 is for 0…10 Vdc input, and FCRy 3-R is for 3…7 kΩ input.

tH 5 is a surface mounted driver that can drive several parallel connected thermal actuators.

supply 24 Vac, 1 VA

input (FCRy 3) 0…10 Vdc < 0,2 mA

input (FCRy 3-R) 3…7 kΩ

output contacts 3 x normally open 230 Vac, 10 A res. (cross locked)

set points (FCRy 3) adjustable, factory settings 2.5 V, 5.0 V and 7.5 V

hysteresis (FCRy 3) adjustable 0,2…1,0 V

set points (FCRy 3-R) 3 kΩ = RL4; 4 kΩ = off; 5 kΩ = RL1;

6 kΩ = RL2; 7 kΩ = RL3

housing IP20, for 35 mm DIn rail

dimensions 45 x 90 x 48 mm

supply 24 Vac

input 5...30 Vac/dc, < 10 mA

output 5 x 24Vac, 1 A, total load max. 3 A

housing IP66, for surface mounting

ReLAyS

ReLAyS

for fan coil controls

driver for thermal actuators

Type arT no.

Type arT no.

FCRY 3 1183070 fan coil relay, input 0…10 Vdc

FCRY 3-R 1183080 fan coil relay, input 3…7 kΩ

TH 5 1183090 driver for thermal actuators, 5 outputs

9

Page 51: Catálogo Produal 2013

PRODUAL l 51 l CAtALOgUe

VVK 2 monitors the status of the water leakage sensors connected to the relay. When the sensor becomes wet the resistance decreases and the alarm relay will be activated. Also the sensor circuit is monitored (alarms if R > 300 kΩ).

LPH 10 monitors the resistance of the sensors. When the sensor becomes wet the resistance decreases and the alarm relay is activated.

VVA and VVn sensors will be used with VVK 2 and LPH 10. the sensors can be installed on the floor and VVn also e.g. on the bottom of the pipe monitoring possible condensation.

supply 24 Vac/dc, 2 VA

measuring range 10 kΩ / 80…300 kΩ, selectable

output change-over contact 60 V, 2 A res.

set point adjustable, LOW < 10 kΩ, HIgH < 80 kΩ

housing IP20, for 35 mm DIn rail

supply 24 Vac/dc

set point fixed, approx. 10 kΩ

output change-over contact 30 Vdc, 1 A res.

alarm indication indicator light and buzzer, with reset button

housing IP20, ABS plastic

dimensions 87 x 86 x 32 mm

sensor resistance approx. 300 kΩ when dry

WAteR LeAKAge ReLAy

WAteR LeAKAge ReLAy

WAteR LeAKAge SenSORS

Type arT no.

Type arT no.

Type arT no.

vvK 2 1187024 water leakage relay

LPH 10 1187010 water leakage relay

vvA 1 1187020 sensor with connection box

vvA 2 1187021 sensor with 2 m cable

vvA 3 1187026 sensor (25 x 200 mm) with 2 m cable and adhesive tape

vvN 1 1187025 sensor, 1 m sensor band and 2 m cable

vvN 2 1187023 sensor, 2 m sensor band and 2 m cable

VVA 2 VVA 1

VVA 3

VVn

9

Page 52: Catálogo Produal 2013

KIASMA, MUSeUM OF COnteMPORARy ARt

Page 53: Catálogo Produal 2013

PRODUAL l 53 l CAtALOgUe

FLtA is a base station for wireless sensors and I/O units. FLtA has 8 x 0...10 Vdc outputs that can be used to deliver the wireless sensor information. the sensor values can also be read via the Modbus. FLtA monitors connected devices for any malfunctions and for the low battery level. FLAn is an antenna for FLtA base station.

FLSeR is a wireless configuration tool for setting the addresses of the sensors, the wireless repeaters and the I/O modules. the tool can also be used for testing the communication signal strength.

FLReP repeaters can be used to extend and boost the range of wireless sensors in difficult environments. It is possible to use up to 8 repeaters for one FLtA base station.

supply 24 Vac/dc, 2 VA

frequency 868.30 MHz Class 1

outputs 8 x 0...10 Vdc

range up to 500 m in the line of sight, 20...100 m in buildings

connectivity max. 99 sensors or max. 20 I/O modules, max. 8 repeaters

network max. 63 base stations

housing IP20, for 35 mm DIn rail

communication Modbus RtU

supply 3,6 V lithium battery

frequency 868.30 MHz Class 1

housing IP20, ABS plastic

supply 12...30 Vac/dc

frequency 868.30 MHz Class 1

housing, FLReP IP20, ABS plastic

housing, FLReP-U IP54

WIReLeSS BASe StAtIOn

WIReLeSS COnFIgURAtIOn tOOL

WIReLeSS RePeAteR

Type arT no.

Type arT no.

Type arT no.

FLTA 1191030 base station for wireless sensors

FLAN 1191040 antenna for FLtA

FLSER 1191070 configuration tool for wireless devices

A04491 A04491 AA lithium battery, 3,6 V 2 Ah

FLREP 1191080 wireless repeater

FLREP-U 1191081 wireless repeater, outdoor

M230/12-4 1184080 230 Vac/12 Vdc 4 VA power supply

10

Page 54: Catálogo Produal 2013

PRODUAL l 54 l CAtALOgUe

teFL wireless room temperature sensors are designed for temperature detection of indoor spaces. the communication between the teFL room units and the FLtA base station is two-way. Commissioning is done by using the wireless FLSeR configuration tool.

teUFL is a wireless sensor for detecting outdoor temperatures. Communication between the sensors and the FLtA base station is two-way. In addition to temperature information, teUFL sensor can send also one 0...10 V signal or one contact (DI) information (teUFL-DI). Commissioning is done by using the wireless FLSeR configuration tool.

supply 3,6 V lithium battery

frequency 868.30 MHz Class 1

range 0…+50 °C

housing IP20, ABS plastic

mounting with screws on wall or on junction box (hole distance 60 mm)

dimensions 86 x 86 x 32 mm

supply 3,6 V lithium battery

frequency 868.30 MHz Class 1

range 1 -50…+150 °C

range 2 0…10 Vdc

mounting with screws, external lugs

housing IP54, cable glands downwards

WIReLeSS tRAnSMItteRS

WIReLeSS tRAnSMItteRS

room °C, % rH

outdoors °C, 0...10 v

Type arT no.

Type arT no.

TEFL 1191010 wireless room sensor

TEFL-P 1191011 wireless room sensor with set point setting

TEFL-RH 1191020 wireless room sensor with %rH

TEFL-RH-P 1191021 wireless room sensor with %rH and set point setting

FL-S5 1191050 S5 switch option for teFL

FL-N 1191060 display option for teFL

FL-DI 1191051 DI option for teFL

A04491 A04491 AA lithium battery, 3,6 V 2Ah

TEUFL 1191100 wireless outdoor temperature sensor

TEUFL-24 1191101 wireless outdoor temperature sensor, 24 Vac/dc supply

TEUFL-DI 1191102 wireless outdoor temperature sensor, with a contact (DI) input

TEUFL-DI-24 1191103 wireless outdoor temperature sensor, with 24 Vac/dc supply and with a contact (DI) input

A04491 A04491 AA lithium battery, 3,6 V 2 Ah

External Pt1000 temperature sensor, e.g. TEAT PT 1000.

10

Page 55: Catálogo Produal 2013

PRODUAL l 55 l CAtALOgUe

KLUFL is a wireless transmitter for detecting outdoor temperatures and humidity. the communication between the sensors and the FLtA base station is two-way. Commissioning is done by using the wireless FLSeR configuration tool. LUX 11 illumination sensor can be connected to the KLUFL transmitter.

supply 3,6 V lithium battery

frequency 868.30 MHz Class 1

range 1 0…100 % rH

range 2 -50…+150 °C

range 3 0…1000 lux

mounting with screws, external lugs

housing IP54, cable gland downwards

WIReLeSS tRAnSMItteRSoutdoors °C, % rH

Type arT no.

KLUFL 1191110 wireless outdoor humidity and temperature transmitter

LUX 11 + NTC 10 1133350 illumination and temperature sensor (ntC 10)

LUX 11 + NTC 20 1133351 illumination and temperature sensor (ntC 20)

A04491 A04491 AA lithium battery, 3,6 V 2 Ah

HDHFL transmitters are designed for detecting carbon dioxide concentration and temperature in the room spaces. HDHFL-RH transmitters have also a humidity output. Commissioning is done by using the wireless FLSeR configuration tool.

supply 24 Vac/dc, 1 VA

frequency 868.30 MHz Class 1

range, CO2 0…2000 ppm

range, temperature 0…+50 °C

range, humidity 0…100 % rH

accuracy, CO2 ±40 ppm +3 % from value

accuracy, temperature ±0,5 °C, at 25 °C

accuracy, humidity ±2 % rH, at 25 °C

outputs 0…10 V < 2 mA

ambient temperature 0...+50 °C

housing IP20, ABS plastic

dimensions 87 x 86 x 30 mm

mounting with screws on wall or on junction box

(hole distance 60 mm)

WIReLeSS tRAnSMItteRSroom ppm CO2, °C, % rH

Type arT no.

HDHFL 1191150 CO2 and °C transmitter with wireless communication

HDHFL-N 1191151 CO2 and °C transmitter with wireless communication and with display

HDHFL-RH 1191160 CO2, °C and % rH transmitter with wireless communication

HDHFL-RH-N 1191161 CO2, °C and % rH transmitter with wireless communication and with display

10

Page 56: Catálogo Produal 2013

PRODUAL l 56 l CAtALOgUe

LAFL is a wireless detector for occupancy monitoring movement. the detector is passive infrared (PIR) which reacts to temperature changes. the communication between the sensors and the FLtA base station is two-way. Commissioning is done by using the wireless FLSeR configuration tool. Mounting bracket and screws are included to the delivery.

supply 3,6 V lithium battery

frequency 868.30 MHz Class 1

ambient temperature 0...+50 °C

housing IP40

coverage angle 140°

WIReLeSS OCCUPAnCy SenSOR

Type arT no.

LAFL 1191120 wireless PIR detector

LAFL-LX 1191121 wireless PIR detector with illumination (0…2000 lux)

AO4491 A04491 AA lithium battery, 3,6 V 2 Ah

PAFL is a wireless pulse counter. the counter can be used to measure pulses from electricity consumption meters, gas flow meters and water consumption meters. Commissioning is done by using the wireless FLSeR configuration tool.

supply 2 x 3,6 V lithium battery or 24 Vac/dc

frequency 868.30 MHz Class 1

max. pulse frequency 20 Hz

min. pulse duration 25 ms

ambient temperature -40...+50 °C

mounting with screws, external lugs

housing IP54, cable gland downwards

WIReLeSS tRAnSMItteRSoutdoors °C, % rH

Type arT no.

PAFL 1191170 wireless pulse counter

A04491 A04491 AA lithium battery, 3,6 V 2 Ah

10

Page 57: Catálogo Produal 2013

PRODUAL l 57 l CAtALOgUe

FLSnIF is a tool for monitoring the functionality of the wireless network. By using this tool you may follow one by one the signals between the wireless field equipment and the base station. Monitoring is possible only for signals which are available at the very moment. A PC with installed monitoring software is needed with the tool. the software is delivered with the tool.

KLM is a mechanical thermometer for a duct installation. two scales are available.

stem Ø 9 x 200 mm

face Ø 100 mm

mounting by a flange

tOOL FOR MOnItORIng WIReLeSS netWORK

MeteRS

Type arT no.

Type arT no.

FLSNIF 1191140 tool for monitoring the wireless network

KLM -40/60 1240010 duct thermometer -40…+60 °C

KLM 0/60 1240020 duct thermometer 0…+60 °C

RyFL is a wireless I/O module for sending and receiving analogue and digital information.

supply 230 Vac (24 Vac to order)

frequency 868.30 MHz Class 1

input 1 contact / 0…10 V, selectable

input 2 contact / 0…10 V, selectable

output 1 0...10 V and 24 Vac PWM / relay 230 Vac, 10 A res., selectable

output 2 0...10 V and 24 Vac PWM / relay 230 Vac, 10 A res., selectable

WIReLeSS I/O MODULe

Type arT no.

RYFL 1191130 wireless I/O module

FLAN 1191040 antenna

11

10

Page 58: Catálogo Produal 2013

PRODUAL l 58 l CAtALOgUe

PeK switches are designed for monitoring over and under pressures and pressure differences in systems that handle air and other non-flammable gases.

DIFFeRentIAL PReSSURe SWItCH

Type arT no.

PEK 300 1240310 differential pressure switch 20...300 Pa

PEK 400 1240320 differential pressure switch 30...400 Pa

PEK 500 1240330 differential pressure switch 50...500 Pa

PEK 1000 1240340 differential pressure switch 200...1000 Pa

PEK 2500 1240350 differential pressure switch 500...2500 Pa

PEK 5000 1240360 differential pressure switch 1000...5000 Pa

PEK-AS 1240300 Accessory kit for PeK and CPS differential pressure switches

CPS switches are designed for monitoring over and under pressures and pressure differences in systems that handle air and other non-flammable gases.

DIFFeRentIAL PReSSURe SWItCH

Type arT no.

CPS 330 1240100 differential pressure switch 20…330 Pa

CPS 450 1240110 differential pressure switch 30…500 Pa

CPS 1100 1240120 differential pressure switch 100…1100 Pa

CPS 4000 1240130 differential pressure switch 500…4000 Pa

PEK-AS 1240300 Accessory kit for PeK and CPS differential pressure switches

11

Page 59: Catálogo Produal 2013

PRODUAL l 59 l CAtALOgUe

COntROL PAneLS FOR OPeRAtIOn / CLeAn ROOMS

Type arT no.

LSML 22 9000340 control panel

LSML 22-2 9000341 control panel, includes also a timer with ventilation status leds

LSML 22-3 9000342 control panel, includes also a humidity display and timer with ventilation status leds

LSML 22-4 9000344 control panel, includes also a humidity display

2-way valves with different sizes and with different kvs values for HVAC applications are available. Valves can be used for controlling heating and cooling. A VA 80 adapter is needed for connecting a nV valve with a BA actuator.

Valve actuators are available for 24 Vac and for 230 Vac supply with a nC or nO function. Control signal may be a PWM or a 0...10 Vdc signal. Connection cables may be fixed (length 1 m) or removable. Different lengths of removable cables are available. An adapter between the valve and the actuator is always needed.

LSML is designed for monitoring and controlling conditions in the operation and clean rooms. the control panel is flush mounted and includes differential pressure and temperature measurements and displays. the temperature measurement needs a separate Pt1000 temperature sensor (not included in the delivery). the panel is also available with some additional features.

COntROL VALVeS

tHeRMAL ACtUAtORS

Type arT no.

Type arT no.

Nv2D10 1230100 valve 3/8” fixed Kvs 1,20

Nv2D10v 1230101 valve 3/8” adjustable Kvs 0,10…0,80

Nv2D10F 1230102 valve 3/8” adjustable Kvs 0,05…0,35

Nv2D15 1230150 valve 1/2” fixed Kvs 1,20

Nv2D15v 1230151 valve 1/2” adjustable Kvs 0,10…0,80

Nv2D15F 1230152 valve 1/2” adjustable Kvs 0,05…0,35

Nv2D20 1230200 valve 3/4” fixed Kvs 1,50

Nv2D20v 1230201 valve 3/4” adjustable Kvs 0,10…0,80

A4004.XX.01 1210010 thermal actuator 24 V nC, fixed cable 1 m

A4104.XX.01 1210020 thermal actuator 24 V nO, fixed cable 1 m

AA2004 1210030 thermal actuator 230 V nC, removable cable (sold separately)

AA4004 1210040 thermal actuator 24 V nC, removable cable (sold separately)

AA4104 1210045 thermal actuator 24 V nO, removable cable (sold separately)

AA5014 1210050 thermal actuator 0...10 V, removable cable (sold separately)

vA 80 1220010 adapter, for e.g. all above mentioned nV valves

Different adapters are available for most common valves in the market.Please check the adapter type for each valve model.

11

Page 60: Catálogo Produal 2013

PRODUAL l 60 l CAtALOgUe

PRODUAL OY’S TERMS OF DELIvERY

Effective as of 1.9.2010

1. SCOPEthese terms of delivery shall be applied to sale of equipment and components (“products”) by Produal Oy (hereinafter “seller”) to its customers and by reference they shall become an integral part of the agreement between the parties unless otherwise agreed (however, not in deliveries in which the object is customized to the individual requirements of the customer, nor in deliveries which include installation work as an integral part). Any amendment made in these terms of Delivery shall be null and void, unless made in writing and duly approved by signatures of competent representatives of the parties.

2. PRICEProdual Oy’s prices that are effective on the date of order shall be used as the basis for pricing. All prices are exclusive of value-added tax, which will be invoiced in accordance with at-each-time applicable legislation.

In the event changes in customs, freight, value-added tax or other general or public payments related to delivery occur, the seller is entitled to change the price of the products in the same proportion that the said changed taxes, prices or payments have affected the price of the products.

3. OFFERthe price referred to in the offer is the net price ex warehouse for a particular unit at the amount in question, excluding value-added tax. the seller’s offer is binding and it valid for thirty (30) days unless otherwise stated in the offer.

If the seller’s offer has been made subject to being unsold, it means an offer immediately from the stock such that products can be sold to a third party while the offer is effective and the seller does not guarantee the sufficiency of products in stock.

4. AGREEMENTAn agreement between the seller and the customer is deemed to have been entered into when

- the contracting parties have signed a written agreement (“supply contract”);

- the customer has approved a binding offer (“order”) in writing or orally; or

- the seller has confirmed in writing or orally an order, as such, that is not based on a offer or that deviates from an offer, and seller accepts this by confirmation of order (“confirmation of order”).

5. DRAwINGS AND PROSPECTUSESInformation presented in prospectuses, pictures, drawings, catalogues and price lists regarding prices, dimensions, weight and performance as well as other data containing technical and other details is provided without obligation unless otherwise agreed between the parties in the agreement. the seller reserves a right to make alterations and changes in the products, provided that such alteration and changes do not materially prevent the use of the products.

All drawings and technical documents relinquished by one party to the other before or after reaching an agreement, and which are needed for manufacturing the products or any part thereof, remain the property of the discloser. the recipient may not without the written consent of the discloser use, copy, relinquish or otherwise give out information about said drawings or technical documents to a third party or use them in its business otherwise than in a manner required by the agreement between the parties.

6. TERMS OF DELIvERYthe terms of delivery are ex warehouse (Incoterms 2000 eXW Produal Oy’s werehouse) unless otherwise agreed in supply contract.

7. PACKINGPrices referred to in price lists and catalogues mean unpacked products.

8. TIME OF DELIvERYthe seller shall deliver the products within the agreed time. If the seller has overdue receivables from the customer, the seller has the right to stop the agreed deliveries, until the overdue receivables have been paid in full. In such event, the time of delivery is deemed to have postponed respectively, and the customer is not entitled to claim any compensation for damages or make other claims resulting from such delay. By stopping the agreed deliveries seller shall not waive any of its rights in connection with or arising out of the agreement or these terms of delivery.

the products are deemed to have been delivered when the risk of loss and damage in respect to the products has transferred to the customer in accordance with the Section 6. in these terms of delivery.

9. NOTIFICATION OF DELAYthe seller and the customer shall without a delay notify each other in the event the delivery or receiving of the products is in danger of delay. When seller or customer receives knowledge of a delay, it shall notify the contracting party of the said delay and the underlying reasons and the new estimated date of delivery.

10. DELIvERY AND INSPECTION OF PRODUCTSthe risk of loss and damage is transferred to the customer when the delivery of products has taken place. Upon the delivery of the products the customer shall confirm that the delivery is in accordance with the agreement and shipment list, and shall carefully inspect that the delivery is externally undamaged. Before using, attaching or installing the products, the customer shall diligently inspect the products with due care once more.

A notification related to the amount, condition or type of the products must be made in writing within 8 working days of the receipt of the products, at the risk of the customer otherwise losing the right to make any claims based on a defect or deficiency.

11. FORCE MAJEUREthe seller is not liable for non-performance of its the obligations under the agreement, if this is due to an impediment which the seller or its subcontractor or supplier cannot overcome, or if the performance would require seller’s sacrifices that are excessive compared to the benefit gained by the customer. When the manufacturer or supplier has not fulfilled their respective agreement and the seller’s delivery is delayed or is left unfulfilled, the seller is not liable for the customer for any damage thereof. Force majeure events shall include but shall not be limited to strikes, lock-outs, boycotts and other labour disputes to which the seller is a subject or a participant.

If the impediment or disparity ends within a reasonable time, the customer is entitled to demand fulfillment of the agreement from the seller. In the event it becomes impossible to fulfil the agreement within a reasonable period of time due to a circumstance stipulated in this Section 11, each party is entitled to terminate the agreement without liability for damage by notifying the other party in writing thereof.

12. PAYMENTthe payment term shall be fourteen (14) days net, if not otherwise agreed in the supply contract. the payment term shall be calculated from the date of invoicing. Upon delay of payment, the customer is liable to pay late payment interest in accordance with the interest rates applied by the seller, as well

12

Page 61: Catálogo Produal 2013

PRODUAL l 61 l CAtALOgUe

as expenses incurred from debt collection. the seller has the right to set-off any receivables from the customer against any payment by the customer.

13. GUARANTEEthe seller gives a twenty-four (24) month guarantee for the material and manufacturing of the delivered products. the guarantee period is deemed to begin on the date of delivery.

In respect to defects in raw material or manufacturing, the seller shall correct the defects provided that product has been sent to the seller without delay or no later than at the end of the guarantee period, at the sole discretion of the seller, by repairing the damaged product or by providing the customer with a new product free from defects and sending it to the customer. the customer shall pay for expenses incurred from sending equipment for repair under warranty, and the seller shall pay for the costs of returning it. the Seller is not liable for reimbursement of any costs related to detaching or reinstallation of the products.

the guarantee does not cover damages caused by accidents, lightning, floods or other acts of god, normal wear and tear, improper, careless or abnormal use or use which is non-compliant with the instructions, abnormal storing, over-stressing, defective maintenance or storage or alterations, changes and installation works that are not done by the seller (or the seller’s authorised representative). the customer is responsible for the selection of material for equipment exposed to corrosion unless agreed otherwise.

If the seller alters the structure of its equipment, the seller is not liable for making similar changes to equipment already purchased.

the guarantee is applicable provided that the customer has, for his part, correctly fulfilled his obligations under the delivery and the agreement.

the seller gives a new guarantee for products repaired or replaced under the guarantee, however only until the end of the guarantee period of the original product.

the seller may against separately invoiced fees repair equipment. the seller shall give a three (3)-month service guarantee that covers material and labour for the repair of equipment outside the guarantee.

this guarantee, under section 13, sets forth the total aggregate liability of the seller in respect to any defects in the products and the seller specifically disclaims any other guarantees, representations and warranties, either express or implied, including but not limited to warranty for fitness for specific purpose.

14. LIMITATION OF LIABILITYParties are responsible for their obligations under the agreement. However, the seller shall not be liable for any indirect or consequential damages to customer including but not limited to loss of production or profit, financing costs, loss of data, costs or damages related to cover purchase, damage to other products or equipment.

the total aggregate liability of the seller under the agreement shall not exceed the contract value of the delivered products under the respective agreement excluding the value added tax. the limitations of liability under this section 14 shall not apply, if the damage is caused by wilful misconduct or gross negligence.

15. INTELLECTUAL PROPERTY RIGHTSBy these terms of delivery or by the agreement the seller does not transfer or assign any intellectual property rights in connection to or arising out of the products or any other intellectual property rights. the customer may only use the product. the customer may not copy, alter, amend or develop

further the products or transfer or assign any intellectual property rights in connection to or arising out of the products.

16. RETURN AND TERMINATION OF THE AGREEMENT An agreement that has become effective is binding and irrevocable and the seller is not obligated to accept a return. Products that have been delivered in accordance with the agreement will be taken back and a maximum reimbursement of 70 % will be given only under the condition that the seller has expressly accepted the return. Such products will be taken back and reimbursed only if they are in their original packaging and condition.

the seller may terminate the agreement forthwith in the event 1) there is an application pending for customer’s bankruptcy, liquidation, restructuring or other similar insolvency proceeding 2) bankruptcy, liquidation, restructuring or other similar insolvency proceeding in respect to the customer has been initiated by a court 3) the customer is otherwise insolvent, or 4) the customer is not able to pay overdue receivables of the seller after a lapse of seven days from the sellers written notice thereof. By terminating the agreement seller does not waive any of its rights under the agreement.

17. NOTICESnotices under the agreement shall be in writing. When sending notices to the other party, the sender is responsible for the arrival of the notice.

18. TRANSFER OF THE AGREEMENTthe parties may not assign or transfer any rights, interest or obligations arising out of the agreement to any third party, without the written consent of the other party. the seller may, however, transfer the rights, interest and obligations arising out of this agreement in connection with a transfer of its business or its business assets to a third party without the consent of the customer. Without prejudice to this Section18, the seller may also transfer, partly or entirely, its contractual receivables to a finance company or other third party without the consent of the customer.

19. THE TITLE AND OwNERSHIPthe title and ownership to the products shall transfer to the customer first when the entire purchase price and other receivables arising out of the agreement have been paid to the seller or a third party to which the receivables have been transferred to.

20. ORDER OF PRECEDENCEthe agreement shall consist of the documents and schedules set out below. In the event the documents conflict with one another the documents shall be applied in an order where a document with smaller number shall prevail over a document with a larger number

1. supply contract / confirmation of order

2. these terms of delivery

3. offer

4. order

21. GOvERNING LAw AND DISPUTE RESOLUTIONthe agreement and these terms of delivery shall be governed by and construed in accordance with the laws of Finland excluding any conflict of law stipulations.

Disputes arising out of the agreements and any provisions there of shall primarily be settled between the parties. If no settlement is reached, disputes shall be resolved in one arbitrator’s arbitration in compliance with the rules of Arbitration Institute of Central Chamber of Commerce of Finland in Helsinki.

Without prejudice to this Section 21, the seller may claim undisputed receivables in a district court of the seller’s domicile.

12

Page 62: Catálogo Produal 2013

PRODUAL l 62 l CAtALOgUe

13

SenSOR SeLeCtIOn gUIDe

Product Measured property

Type Page °C RH CO2 CO Pa bar m/s m3/s lux w/m2 H2O PIR Qty

IVL 7 • •tUnA 20 18 •

UV 7 18 • •VS 3000 18 • •

PeL 8...9 •PeK / CPS 58 •

IML 9 • •KLH 11 • •KLK 11 • •

KLHJ 12 • •KLU 12 • •

KLUFL 55 • • • 1)

LUX 13...14 • •MMSP1 14 •

VPeL 15 •VPL 15 •HDH 16 • • •

HDHFL 16, 55 • • •HDK 16 • •HDU 17 • •HML 17 •teAt 27 •tenA 28 •teKV 29 •teV 29 •teP 30 •

tePK 30 •teK 31 •

teKHA 31 •teKA 32 •teKy 34 •

teL 36 •teM 36 •

teSK 37 •teHR 37...38 •teFL 54 • •teHU 39 •teU 39...40 •

teUFL 54 •teS 40 •LA 46 •

LAFL 56 • •PLt 47 •

KA 10 13 •SA 10 19 •

VVA / VVn 51 •PAFL 56 •

1) Separate light sensor needed.

Page 63: Catálogo Produal 2013

PRODUAL l 63 l CAtALOgUe

Output

Type Ω v mA relay Modbus wireless

IVL • •tUnA 20 • •

UV7 •VS 3000 •

PeL • •PeK / CPS •

IML • •KLH • •KLK • •

KLHJ • •KLU • •

KLUFL • • •LUX • • •

MMSP1 • •VPeL • •VPL • •HDH • •

HDHFL • •HDK •HDU •HML • •teAt • • •tenA • • •teKV • • •teV • • •teP • • •

tePK • • •teK • • •

teKHA •teKA • • •teKy • • •

teL •teM •

teSK • • •teHR • • • •teFL •teHU •teU • • •

teUFL •teS •LA •

LAFL •PLt •

KA 10 • •SA 10 • •

VVA / VVn •PAFL •

13

Page 64: Catálogo Produal 2013

PRODUAL l 64 l CAtALOgUe

Sensor element

PTC 1000

Pt 100

Pt 1000

Ni 1000

Ni 1000-

LG

NTC 1.8

NTC 2.2

NTC 3.0

NTC 10

NTC 20

NTC 10-AN

NTC 10-C

NTC 10-KB

KP 10

tol.±1,3°C/ 25°C

±0,3°C/ 0°C

en60751 B

±0,3°C/ 0°C

en60751 B

±0,4°C/ 0°C

DIn43760

±0,4°C/0°C tcr 5000ppm

Siemens

±0,3°C/ 25°C

tAC1800

±0,25°C/ 25°C

Johnson

±0,25°C/ 25°C

±0,25°C/ 25°C

trend

±0,25°C/ 25°C

H&W

±0.25°C/ 25°C

Andover

±0.25°C/ 25°C

Carel

±0.5°C/ 25°C

LM335Z 10 mV/K

Temp. °C Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω v

140 2128 153.38 1533.8 1909 1737 71 53 70 235 351 298 381 324

130 2041 149.82 1498.2 1833 1675 87 68 90 301 459 377 474 385

120 1923 146.06 1460.6 1760 1615 110 90 117 389 609 483 597 467

110 1810 142.29 1422.9 1688 1557 139 115 153 511 818 624 758 576

100 1700 138.50 1385 1618 1500 178 153 204 679 1114 817 973 723 3,73

95 1647 136.60 1366 1583 1472 202 178 236 787 1307 940 1108 815 3,68

90 1594 134.70 1347 1549 1444 230 207 275 916 1541 1084 1266 923 3,63

85 1543 132.80 1328 1516 1417 264 241 321 1071 1823 1255 1451 1048 3,58

80 1492 130.89 1308.9 1483 1390 303 283 377 1256 2166 1458 1668 1194 3,53

75 1442 128.98 1289.8 1450 1364 349 334 444 1480 2585 1700 1924 1364 3,48

70 1394 127.07 1270.7 1417 1337 403 395 525 1751 3099 1990 2228 1562 3,43

65 1347 125.16 1251.6 1385 1311 468 469 625 2082 3732 2339 2588 1791 3,38

60 1300 123.24 1232.4 1353 1285 545 560 746 2488 4517 2760 3020 2056 3,33

55 1254 121.32 1213.2 1322 1260 638 673 896 2986 5494 3271 3536 2358 3,28

50 1209 119.40 1194 1291 1235 750 811 1080 3602 6718 3893 4160 2702 3,23

45 1166 117.47 1174.7 1260 1210 885 984 1310 4368 8259 4656 4911 3088 3,18

40 1123 115.54 1155.4 1230 1186 1049 1200 1598 5326 10211 5594 5827 3517 3,13

35 1081 113.61 1136.1 1200 1162 1250 1471 1959 6532 12698 6754 6940 3987 3,08

30 1040 111.67 1116.7 1171 1138 1496 1814 2417 8055 15887 8197 8313 4492 3,03

29 1032 111.28 1112.8 1165 1132 1552 1893 2522 8408 16628 8525 8622 4597 3,02

28 1024 110.90 1109 1159 1128 1610 1977 2633 8777 17407 8869 8944 4703 3,01

27 1016 110.51 1105.1 1153 1123 1671 2064 2749 9165 18228 9229 9281 4809 3,00

26 1008 110.12 1101.2 1147 1119 1734 2156 2872 9572 19092 9606 9632 4917 2,99

25 1000 109.73 1097.3 1141 1114 1800 2252 3000 10000 20000 10000 10000 5025 2,98

24 992 109.35 1093.5 1136 1109 1869 2353 3135 10452 20962 10413 10380 5134 2,97

23 984 108.96 1089.6 1130 1105 1941 2458 3277 10923 21973 10845 10780 5243 2,96

22 977 108.57 1085.7 1124 1100 2017 2572 3426 11417 23039 11297 11200 5353 2,95

21 969 108.18 1081.8 1118 1095 2095 2689 3583 11938 24164 11771 11630 5462 2,94

20 961 107.79 1077.9 1112 1091 2177 2813 3748 12490 25350 12268 12090 5573 2,93

15 923 105.85 1058.5 1084 1068 2649 3538 4714 15710 32346 15136 14690 6126 2,88

10 886 103.90 1039 1056 1045 3241 4482 5971 19900 41567 18787 17960 6667 2,83

5 850 101.95 1019.5 1028 1022 3989 5718 7619 25400 53812 23462 22050 7183 2,78

0 815 100.00 1000 1000 1000 4940 7353 9795 32660 70203 29490 27280 7661 2,73

-5 781 98.04 980.4 973 978 6159 9533 12694 42340 92322 37316 33900 8093 2,68

-10 748 96.09 960.9 946 956 7730 12460 16589 55340 122431 47549 42470 8472 2,63

-15 716 94.12 941.2 919 935 9771 16428 21868 72980 163777 61030 53410 8796 2,58

-20 685 92.16 921.6 893 914 12443 21860 29092 97120 221088 78930 67770 9067 2,53

-25 655 90.19 901.9 867 893 15969 29398 39073 130400 301297 102890 86430 9288 2,48

-30 625 88.22 882.2 842 872 20659 39908 53005 177000 414698 135233 111300 9466 2,43

-35 597 86.25 862.5 816 851 26955 54751 72658 243120 576763 179280 9605 2,38

-40 570 84.27 842.7 791 831 35480 75953 100701 337270 810861 239831 9712 2,33

-45 544 82.29 822.9 767 811 47135 106603 141183 473370 1152992 323859 9793

-50 518 80.31 803.1 743 791 63229 151470 200348 672600 1659082 441667 9854

SenSOR CHARACteRIStICS

14

Page 65: Catálogo Produal 2013

PRODUAL l 65 l CAtALOgUe

15

Sensor element

PTC 1000

Pt 100

Pt 1000

Ni 1000

Ni 1000-

LG

NTC 1.8

NTC 2.2

NTC 3.0

NTC 10

NTC 20

NTC 10-AN

NTC 10-C

NTC 10-KB

KP 10

tol.±1,3°C/ 25°C

±0,3°C/ 0°C

en60751 B

±0,3°C/ 0°C

en60751 B

±0,4°C/ 0°C

DIn43760

±0,4°C/0°C tcr 5000ppm

Siemens

±0,3°C/ 25°C

tAC1800

±0,25°C/ 25°C

Johnson

±0,25°C/ 25°C

±0,25°C/ 25°C

trend

±0,25°C/ 25°C

H&W

±0.25°C/ 25°C

Andover

±0.25°C/ 25°C

Carel

±0.5°C/ 25°C

LM335Z 10 mV/K

Temp. °C Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω v

140 2128 153.38 1533.8 1909 1737 71 53 70 235 351 298 381 324

130 2041 149.82 1498.2 1833 1675 87 68 90 301 459 377 474 385

120 1923 146.06 1460.6 1760 1615 110 90 117 389 609 483 597 467

110 1810 142.29 1422.9 1688 1557 139 115 153 511 818 624 758 576

100 1700 138.50 1385 1618 1500 178 153 204 679 1114 817 973 723 3,73

95 1647 136.60 1366 1583 1472 202 178 236 787 1307 940 1108 815 3,68

90 1594 134.70 1347 1549 1444 230 207 275 916 1541 1084 1266 923 3,63

85 1543 132.80 1328 1516 1417 264 241 321 1071 1823 1255 1451 1048 3,58

80 1492 130.89 1308.9 1483 1390 303 283 377 1256 2166 1458 1668 1194 3,53

75 1442 128.98 1289.8 1450 1364 349 334 444 1480 2585 1700 1924 1364 3,48

70 1394 127.07 1270.7 1417 1337 403 395 525 1751 3099 1990 2228 1562 3,43

65 1347 125.16 1251.6 1385 1311 468 469 625 2082 3732 2339 2588 1791 3,38

60 1300 123.24 1232.4 1353 1285 545 560 746 2488 4517 2760 3020 2056 3,33

55 1254 121.32 1213.2 1322 1260 638 673 896 2986 5494 3271 3536 2358 3,28

50 1209 119.40 1194 1291 1235 750 811 1080 3602 6718 3893 4160 2702 3,23

45 1166 117.47 1174.7 1260 1210 885 984 1310 4368 8259 4656 4911 3088 3,18

40 1123 115.54 1155.4 1230 1186 1049 1200 1598 5326 10211 5594 5827 3517 3,13

35 1081 113.61 1136.1 1200 1162 1250 1471 1959 6532 12698 6754 6940 3987 3,08

30 1040 111.67 1116.7 1171 1138 1496 1814 2417 8055 15887 8197 8313 4492 3,03

29 1032 111.28 1112.8 1165 1132 1552 1893 2522 8408 16628 8525 8622 4597 3,02

28 1024 110.90 1109 1159 1128 1610 1977 2633 8777 17407 8869 8944 4703 3,01

27 1016 110.51 1105.1 1153 1123 1671 2064 2749 9165 18228 9229 9281 4809 3,00

26 1008 110.12 1101.2 1147 1119 1734 2156 2872 9572 19092 9606 9632 4917 2,99

25 1000 109.73 1097.3 1141 1114 1800 2252 3000 10000 20000 10000 10000 5025 2,98

24 992 109.35 1093.5 1136 1109 1869 2353 3135 10452 20962 10413 10380 5134 2,97

23 984 108.96 1089.6 1130 1105 1941 2458 3277 10923 21973 10845 10780 5243 2,96

22 977 108.57 1085.7 1124 1100 2017 2572 3426 11417 23039 11297 11200 5353 2,95

21 969 108.18 1081.8 1118 1095 2095 2689 3583 11938 24164 11771 11630 5462 2,94

20 961 107.79 1077.9 1112 1091 2177 2813 3748 12490 25350 12268 12090 5573 2,93

15 923 105.85 1058.5 1084 1068 2649 3538 4714 15710 32346 15136 14690 6126 2,88

10 886 103.90 1039 1056 1045 3241 4482 5971 19900 41567 18787 17960 6667 2,83

5 850 101.95 1019.5 1028 1022 3989 5718 7619 25400 53812 23462 22050 7183 2,78

0 815 100.00 1000 1000 1000 4940 7353 9795 32660 70203 29490 27280 7661 2,73

-5 781 98.04 980.4 973 978 6159 9533 12694 42340 92322 37316 33900 8093 2,68

-10 748 96.09 960.9 946 956 7730 12460 16589 55340 122431 47549 42470 8472 2,63

-15 716 94.12 941.2 919 935 9771 16428 21868 72980 163777 61030 53410 8796 2,58

-20 685 92.16 921.6 893 914 12443 21860 29092 97120 221088 78930 67770 9067 2,53

-25 655 90.19 901.9 867 893 15969 29398 39073 130400 301297 102890 86430 9288 2,48

-30 625 88.22 882.2 842 872 20659 39908 53005 177000 414698 135233 111300 9466 2,43

-35 597 86.25 862.5 816 851 26955 54751 72658 243120 576763 179280 9605 2,38

-40 570 84.27 842.7 791 831 35480 75953 100701 337270 810861 239831 9712 2,33

-45 544 82.29 822.9 767 811 47135 106603 141183 473370 1152992 323859 9793

-50 518 80.31 803.1 743 791 63229 151470 200348 672600 1659082 441667 9854

COntROLLeR SeLeCtIOn gUIDe

Controller

HLS 16 HLS 21 HLS 33 HLS 34 HLS 35 HLS 44 HLS 44-v HLS 45 PDS 2 PDS 2.2 HS 2.2

App

licat

ion

4-pipe fan coil unit control • • • •

2-pipe fan coil unit control • •

Floor heating • • • • •Floor heating/

cooling • • •

Chilled beam • • • • • • • •Heating radiator

control • • • • • • • •

Domestic water temperature control •

Air handling unit control •

Universal controller • •

Act

uato

r thermal • • • • • • • • • • •3-point • • • • • • •0...10 V • • • • • • • • •

Func

tion

Control stages 1 2 2/3 2/3 1 2/3 2/3 1/2 1 1 1

3-speed fan control with FCRy 3 • • • •

eC fan control • • •

VAV control • • • • •

Summer/winter • • •CO2 based

ventilation control • • • •

Lighting control on/off

Modbus • • • • • • •

Page 20 21 21 22 22 23 23 24 24 25 25

Page 66: Catálogo Produal 2013

PRODUAL l 66 l CAtALOgUe

16

InDeX

teAt xx 27

teFL 54

teFL-P 54

teFL-RH 54

teFL-RH-P 54

teHR LL 38

teHR LU 38

teHR xx 37

teHR xx-P 38

teHR-M 38

teHR-M-n 38

teHU xx 39

teK xx 31

teKA xx 32

teKA xx-500 33

teKHA xx 31

teKV xx 29

teKy xx 34

teL xx 36

teM xx 36

tenA xx 28

teP xx 30

tePK xx 30

teS xx 40

teSIM ntC 10 40

teSIM Pt 1000 40

teSK xx 37

teU LL 40

teU LU 40

teU xx 39

teUFL 54

teUFL-24 54

teUFL-DI 54

teUFL-DI-24 54

teV xx 29

tH 5 50

tUnA 20 18

UMP 3 43

UV 7 18

UV 10 44

VA 80 59

VH 1000 18

VK 10 7

VPeL 1.0/2.5 15

VPeL 4.0/6.0 15

VPL 16 15

VPL 16-n 15

VPL 60 15

VPL 60-n 15

VR 1000 18

VS 3000 18

VVA 1 51

VVA 2 51

VVA 3 51

VVK 2 51

VVn 1 51

VVn 2 51

Axx 59

AAxx 59

AO 2 44

AO 3 44

AR 1 49

At 80 27

AtH 300 27

AtH 80 27

AtM 80 27

AtS 80 27

BAK 64 19

CPS xx 58

DA 6 42

eJV 24-Pt 4

FCRy 3 50

FCRy 3-R 50

FLAn 53

FLReP 53

FLReP-U 53

FLSeR 53

FLSnIF 57

FLtA 53

HDH 16

HDH-AL3 16

HDH-C 16

HDHFL 16

HDHFL 55

HDHFL-n 16

HDHFL-n 55

HDHFL-RH 16

HDHFL-RH 55

HDHFL-RH-n 16

HDHFL-RH-n 55

HDH-M 16

HDH-M-n 16

HDH-M-RH 16

HDH-M-RH-n 16

HDH-n 16

HDH-RH 16

HDH-RH-n 16

HDK 16

HDK-C 16

HDK-n 16

HDU 17

HDU-n 17

HLS 16 20

HLS 21 21

HLS 33 21

HLS 34 22

HLS 35 22

HLS 44 23

HLS 44-SeR 23

HLS 44-V 23

HLS 45 24

HLS 45-SeR 24

HM-KK 17

HML 17

HML-C 17

HML-n 17

HMV 17

HM-VS 17

HS 2.2 25

IML 9

IML-M 9

ISO 10 42

IVL 02 7

IVL 02-n 7

IVL 10 7

IVL 10-n 7

IVL 20 7

IVL 20-n 7

JV 24-Pt 4

JVA 24 4

JVS 24 4

Jy 43

KA 10 13

KA 10-eXt 13

KLH 100 11

KLH 100-n 11

KLH 420 11

KLH 420-n 11

KLHJ 100 12

KLHJ 100-n 12

KLH-M 11

KLH-M-n 11

KLK 100 11

KLK 100-n 11

KLM 0/60 57

KLM -40/60 57

KLU 100 12

KLU 100-n 12

KLUFL 55

KO IVS 41

KO PRA 46

LA 14 46

LA 15 46

LA-RAJ 46

LAFL 56

LAFL-LX 56

LAP 1 48

LAP 10 48

LAP 10-t 48

LAP 5 48

LAP 5-t 48

LeK 24-Pt 5

LeKA 24 49

LK 24-Pt 5

LK 24-Pt 0/100 5

LLK 41

LLK-n 41

LPH 10 51

LSML 22 59

LSML 22-2 59

LSML 22-3 59

LSML 22-4 59

LUK 41

LUK-n 41

LUX 11 14

LUX 24 13

LUX 34 13

LUX 34-100 13

M230/12-4 45

M230/24-15 45

M230/24-30 45

MIO 12-Pt 42

MIO 12-V 42

MMSP1 14

nV2D xx 59

PDS 2 24

PDS 2.2 25

PAFL 56

PeK xx 58

PeK-AS 58

PeL 8

PeL 1000 9

PeL 1000-n 9

PeL 2500 8

PeL 2500-n 8

PeL 25K 8

PeL 25K-n 8

PeL-AS 8

PeL-n 8

PJP 1 48

PJP 2 48

PJP 4 48

PJR 4 20

PLt 12 47

PLt 24 47

PLt 24-K 47

PMU 3 43

PP-PK Rxx 10

PP-SK Lxx 10

PR 10/440 20

PR 50/440 20

PRMK 20

PVA 24 4

PyR 4 44

Ry 1 49

Ry 1-K 49

Ry 1-KK 49

Ry 1-U 49

Ry 1-U-K 49

RyFL 57

RyV 16-U 49

RyVA 16 49

SA 10 19

StS 1 20

StS 4 20

Page 67: Catálogo Produal 2013

PRODUAL l 67 l CAtALOgUe

Page 68: Catálogo Produal 2013

COntACt InFORMAtIOn

Kotka Produal Oy Keltakalliontie 18 48770 Kotka

tel. +358 5 230 9200fax. +358 5 230 [email protected]

JyväskyläProdual Oytahvontie 240420 Jyskä

SwedenProdual Sverige ABpostal address: Box 611, 13526 tyresöstreet address: Solkraftsvägen 16B, 13570 Stockholmtel. +46 8 555 985 [email protected]

DenmarkProdual A/SUdlejrevej 31-5, 3650 Ølstykketel. +45 70 26 03 [email protected]

FranceProdual S.A.S.Bureau 302-11, rue Albert einstein, 77420 Champs sur Marnetel. +33 6 19 29 16 [email protected]

RussiaOOO ProdualRubcovskaya naberezhnaya 2 k 1, 105082 Moscowtel. +7 495 509 [email protected]

PolandProdual Oyul. Płochocińska 19/110, 03-191 Warszawatel. +48 504 024 [email protected]

FinLanD