Catalogo Nihon Kohden

56
( ) Patient Monitoring Accessories

Transcript of Catalogo Nihon Kohden

Page 1: Catalogo Nihon Kohden

( )Patient Monitor ingAccessories

Page 2: Catalogo Nihon Kohden

Always Per fect ly Ba lanced:Or ig ina l accessor ies for opt imal examinat ion resu l ts( )

Page 3: Catalogo Nihon Kohden

Your patient is unique. Our accessories are original.

Health is man’s most valuable asset and therefore products that help to

preserve health are not to be equated with any other possessions. Espousing this

philosophy is something we consistently do, since we concentrate exclusively on

the development, manufacture, marketing and servicing of medical devices — an

activity we discharge not as a medical department or an enterprise sector within

a large concern with many business areas, but rather in our capacity as a large,

internationally reputed specialist enterprise for this specialist domain. We are

therefore able to target all our decision-making processes precisely towards

elucidating what is necessary and beneficial for this sensitive medical electronics

market.

In our view there is always a direct link between technical and methodical

innovations when it comes to research and development of the latest tech-

nologies. Only the synthesis of these two components will ensure that the human

being will really be the final focus of all efforts. Only those devices that, in

addition to optimal technology, are able to assure enhanced patient friendliness,

ease of operation and diagnostic accuracy will be placed on the market.

The direct interface to the patient is an essential feature of our highly-

developed medical devices and systems. The method of signal acquisition plays a

pivotal role in collecting the requisite information for successful diagnosis and

therapy. We supply a comprehensive range of accessories and consumable

materials for each of our products. These are developed, tested and

manufactured together with the corresponding devices and are thus precisely

tailored to their technical requirements. This is because the quality and reliability

of medical devices and systems are inextricably bound up with the quality and

reliability of the accessories used.

Only the use of original accessories guarantees optimal examination results

and makes an important contribution towards ensuring that your device will

continue to function impeccably and reliably even in years to come, while

preserving the device’s features and functional capabilities.

With this catalogue we would now like to give you an overview of our accessories

and consumable materials.

I am delighted to have the pleasure of presenting this catalogue to you and hope

to have gained your interest in the products behind this quality philosophy!

Yours sincerely,

Dirk Mehlhorn

Head of Department for Technology and Quality Assurance

3

Page 4: Catalogo Nihon Kohden

Highest Safety and Quality Standards

Our safety guide

Anyone manufacturing medical devices and accessories must have complete faith

in the technology, quality and reliability of their products. Prolonged trial phases,

continuous quality checks and state-of-the-art production facilities are indis-

pensable prerequisites here.

This is because the target being aspired to is: absolute reliability, error-free

operation – especially during those decisive seconds. NIHON KOHDEN has

already taken appropriate in-depth measures here. The national and international

test standards regulating medical devices are stringent — but often not

sufficiently stringent as far as we are concerned. If we believe that the state-of-

the-art permits and warrants the use of even more exacting standards, then we

shall let these guide us.

Quality Assurance in Practice

A comprehensive quality assurance system ensures that each of the more

than 3,000 NIHON KOHDEN staff members makes his/her contribution towards

development, manufacture, marketing and customer services such that maximum

product quality is guaranteed.

NIHON KOHDEN is certified as per ISO 9001:2000, JIS Q 9001:2000, ISO

13485:1996, ISO 14001:1996, JIS Q 14001:1996 and ISO 13488:2001.

4

Page 5: Catalogo Nihon Kohden

Trailblazers in Medical Technology

A lighthouse stands supreme, showing others the way. With the symbolic

light beam of our stylised lighthouse, we express our claim as well as our sense

of assurance of standing supreme, while at the same time playing a trailblazing

role.

As one of the leaders in innovation and technology we have specialized

exclusively in the field of medical technology.

Here we feel committed to progress in medicine.

Here we have our core competence.

Here, in the services of health, we find trailblazing solutions in the domains of

• Neurology

• Cardiology

• Patient monitoring

• Haematology

Fighting Disease with Electronics

NIHON KOHDEN shares with you a common goal: »Fighting Disease« – for the

health and quality of life of all patients. To that effect, we support your everyday

activities »with Electronics« – with technical product innovations in line with the

latest innovations in medical technology.

NIHON KOHDEN is active in research and development. The main focus of

our activities is on permanently improving diagnostic facilities. We develop all

devices for and together with our clients – in the services of the patient. Your

requirements and experiences gleaned from everyday practice always serve as

the cornerstone of our efforts. You are our yardstick when developing new

systems and technologies — from the most minute technical detail right up to the

complex system solution.

NIHON KOHDEN is Tradition and Future at the same time. With our

competence spanning more than 50 years, our various technological innovations

and ideas, we shall continue to be a strong partner for you in the future too.

Allow yourself to be convinced of the quality and functional capabilities of our

products, services and enterprise.

5

Page 6: Catalogo Nihon Kohden

BluPRO® Sensors for SpO2 Measurement

Thanks to the consistent further development of its SpO2 sensor technology,NIHON KOHDEN is once again able to demonstrate with the BluPRO® series ofprobes just how precise and stable measurement results can be when measuringarterial oxygen saturation. Thanks to the parallel mounting of the sensor components, the reusable SpO2

sensor fits comfortably on any finger. Moreover, the mechanical design providesfor exact alignment of the optical components in respect of each other andexternal light is effectively shielded out. The sensors are water tight and insensitiveto disinfectants. The underlying philosophy when developing the single-use SpO2 sensors wasprecise positioning of LED and photodetector. Therefore the two opticalcomponents are designed with mechanical separation. The paediatric version of the sensors features an additional child-friendly motifseries.

CapONE – CO2 Main stream sensor for capnography

CapONE – innovative and extraordinary in monitoring non-intubated patients:

No module needed – CapONE is a main stream sensor and doesnot extract a gas sample from the patient’s respiratory flow. High signal quality – CapONE measures close to the patient.

Its quality is particularly demonstrated in low-flow respiration and oral breathing.

Extensive patient safety – CapONE needs no gas sampling line.This reduces the risk of infection posed to the patient as a result

of a potentially contaminated gas sampling tube.

Multi-parameter connection

NIHON KOHDEN patient monitors are equipped with in-novative multi-parameter connectors. This unique tech-nology offers high flexibility in terms of parameter selection.The multi-parameter connector automatically detects thesensor cable connected and independently configures thepatient monitor in accordance with the related parameter.

Innovat ions · H ighl ights

6

( )

Page 7: Catalogo Nihon Kohden

Contents

ECG and Respiration 9 to 13Connection cables 10ECG electrodes 11 to 13Respiration (thermistor respiration measurement) 13

SpO2 Measurement 14 to 17SpO2 connection cord 15Reusable SpO2 probes 16Disposable SpO2 probes 17

Temperature Measurement 18 to 19

Non-invasive Blood Pressure (NIBP) 20 to 23Hoses 21Cuffs (reusable, latex-free) 22Disposable cuffs 23

Invasive Blood Pressure (IBP) 24 to 25

Cardiac Output (CO) 26 to 27

Capnography 28 to 32Main stream method 29 to 31CO2 calibration gas 31Side stream method 32

FiO2 Measurement and Measurement of Anaesthetic Gas 33 to 35FiO2 measurement 34Measurement of anaesthetic gas 34 to 35

Dye Densitograph 36 to 37Dye 37Sensors 37

Other Accessories 38 to 39Power cable 39Cleaning pen 39Touch pen 39Connection cable for external equipment 39

Batteries 40 to 41Batteries 41Battery charger (external) 41

Recording Paper 42 to 43

Accessories for Telemetry Transmitter 44 to 50ECG electrode leads 45ECG electrodes 46 to 47Reusable SpO2 probes 48Disposable SpO2 probes 49Cuffs (reusable, latex-free) 50Bags 50

Warranty/Remarks 51 to 52

Index as per Supply Code No./Article No. 53 to 54

7

Page 8: Catalogo Nihon Kohden

8

Overview of our Patient Monitoring Systems

The original accessories in this catalogue are optimally tailored to our patient monitors —

for reliable examination results and error-free operation of your equipment for many

years to come.

BSM-2300 BSM-4100 BSM-5100

BSM-9510 BSS-9800 OPV-1500

WEP-4200 WEP-8400 DDG-2001

ZB-810/811ZB-820/823

ZB-930, ZS-930, ZM-930ZB/ZS-910/920, ZM-920

ZS-940

Page 9: Catalogo Nihon Kohden

Connection cables · page 10

ECG electrodes · page 11 to 13

Respiration (thermistor respiration measurement) · page 13

ECG and Respirat ion

9

( )

Page 10: Catalogo Nihon Kohden

EC

G A

ND

RE

SP

IRA

TIO

N

10

ECG and Respiration (Impedance Method)

Connection Cables

• K911 BR-903P Electrode lead for 3 electrodes · clip type · cable length 0.8 m R x x x x x x 1* – 1

• K910A BR-913P Electrode lead for 3 electrodes · snap type · cable length 0.8 m R x x x x x x 1* – 1

• K912 BR-906P Electrode lead for 6 electrodes · clip type · cable length 0.8 m R x x x x x – 1* – 1

• K915 BR-916P Electrode lead for 6 electrodes · snap type · cable length 0.8 m R x x x x x – 1* – 1

• K922 JC-906P Connection cord for connecting electrode lead K910, K911, K912 R x x x x x – 1* – 1and K915 to patient monitor · cable length 3.0 m

• L060 JC-103T Connection cord for connecting electrode lead K910 and K911 to R – – – – – x 1* – 1patient monitor · cable length 3.0 m

• K901 BJ-900P ECG patient cable for 12 channel ECG · comprising electrode R – x x x x – 1* – 1lead and connection cord · cable length 3.8 m

• K921 JC-900P ECG patient cable for 12 channel ECG · for connection of dis- R – x x x x – 1* – 1posable electrodes with DIN type connector (touch-proof) · cable length 3.0 m

• 6124-039432 ECG connection cord cover for K922 connection cord R x x x x x – 1* – 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = see also section Accessories for Telemetry Transmitter

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

[1] K910A | [2] K911 [1] K915 | [2] K912 K922

L060 K901 K921

[1] [2][1] [2]

6124-039432

Page 11: Catalogo Nihon Kohden

EC

G A

ND

RE

SP

IRA

TIO

N

11

ECG and Respiration (Impedance Method)

ECG Electrodes

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• G217 D-90 Vitrode D · disposable ECG electrode · electrode material: D x x x x x x 1* – 30 x 3Ag/AgCl · size: ca. 55 mm dia · applicable for X-ray, CT and MRT · patent pending electrode adhesive (2-dimensional elastic fortension) · very kind to the skin · suitable for long term measurements (> 72 h) · wash-, shower- and bath-tolerant · for universal use

• G207 L-150X Vitrode L · disposable ECG electrode · electrode material: D x x x x x x 1* – 5 x 30Ag/AgCl · size: ca. 35 mm dia · applicable for X-ray, CT and MRT · strong adhesive · resistant against detachment by solvents · foam tape · for universal use

• G210C F-150S Vitrode F · disposable ECG electrode (small) · electrode D x x x x x x 1* – 50 x 3material: Ag/AgCl · size: ca. 18 mm x 36 mm · cotton tape · electrically conductive adhesive gel · repeatedly positionable · very kind to the skin · very suitable for children · not for use in operating rooms

• G210D F-150M Vitrode F · disposable ECG electrode (medium) · electrode D x x x x x x 1* – 50 x 3material: Ag/AgCl · size: ca. 25 mm x 45 mm · cotton tape · electrically conductive adhesive gel · repeatedly positionable · very kind to the skin · not for use in operating rooms

• G201 Bs-150 Vitrode Bs · disposable ECG electrode · electrode material: D x x x x x x 1* – 30 x 5Ag/AgCl · size: ca. 47 mm x 47 mm · soft breathable cotton tape with an elastic quality for tension · hydro gel for low electrode impedance and stable measurements even on dry skin · for universal use

• G204 C-150 Vitrode C · disposable ECG electrode · electrode material: D x x x x x x 1* – 30 x 5Ag/AgCl · size: ca. 47 mm x 47 mm · soft breathable cotton tape with an elastic quality for tension · hydro gel for low electrode impedance and stable measurements even on dry skin · the electrode gel is almost removed after removing the electrode · for universal use

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = see also section Accessories for Telemetry Transmitter

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

G217 G207 G210C

G210D G201 G204

Page 12: Catalogo Nihon Kohden

EC

G A

ND

RE

SP

IRA

TIO

N

12

ECG and Respiration (Impedance Method)

ECG Electrodes

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

G250 G272A G272B

G271KG272C G271A

• G250 J-150 Vitrode J · disposable ECG electrode · electrode material: D x x x x x x 1* – 30 x 5Ag/AgCl · size: ca. 40 mm dia · foam tape with excellent adhesion unaffected by the effects of sweat or solvents · hydro gel forlow electrode impedance and stable measurements even on dry skin · the electrode gel is almost removed after removing the electrode · for universal use

• G272A V-090M3 Vitrode V · disposable ECG electrode · electrode material: D x x x x x x – – 30 x 3Ag/AgCl · size: ca. 25 mm x 45 mm · DIN type connector (touch-proof) with 100 cm electrode lead · electrode and cable applicable for X-ray, CT and MRT · conductive hydro gel with excellent adhesive advantages · foam and cotton tape · for universal use · 3 electrodes for ECG monitoring · coloured cable (red, yellow, green)

• G272B V-040M4 Vitrode V · disposable ECG electrode · same as G272A, but D x x x x x x – – 10 x 4with 4 electrodes for limb leads · coloured cable (red, yellow, green, black)

• G272C V-060M6 Vitrode V · disposable ECG electrode · same as G272A, but D x x x x x x – – 10 x 6with 6 electrodes for chest leads · coloured cable (red, yellow, green, brown, black, purple)

• G271K V-120SK Vitrode V-s · disposable ECG electrode · electrode material: D x x x x x x – – 40 x 3Ag/AgCl · size: ca. 20 mm x 20 mm · DIN type connector (touch-proof) with 60 cm electrode lead · electrode and cable applicable for X-ray, CT and MRT · foam and cotton tape with excellent adhesive advantages · very kind to the skin · very small – for neonates and infants · child friendly with motif print »Kitty« · coloured cable (red, yellow, green)

• G271A V-120S3 Vitrode V · disposable ECG electrode · same as G271K, but D x x x x x x – – 40 x 3without motif print

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = see also section Accessories for Telemetry Transmitter

Page 13: Catalogo Nihon Kohden

EC

G A

ND

RE

SP

IRA

TIO

N

13

ECG and Respiration (Impedance Method) · Respiration (Thermistor Respiration Measurement)

ECG Electrodes

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• G300A N-03IS3 Vitrode N · disposable ECG electrode · electrode material: D x x x x x x 1* – 10 x 3Ag/AgCl · size: ca. 14 mm x 25 mm · DIN type connector (touch-proof) with 60 cm electrode lead · electrode and cable applicable for X-ray, CT and MRT · fleece tape with excellent adhesive advantages · very kind to the skin · very small – for neonates and infants · child friendly with motif print »Sweezy« · coloured cable (red, yellow, green)

• NKD-H34SG Disposable ECG electrode ARBO® · size: ca. 45 mm dia · applicable D x x x x x x 1* –30

for X-ray, CT and MRT · hydro gel · very strong adhesive · 72 h endurance test · shower- and wash-tolerant · with skin remover

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = see also section Accessories for Telemetry Transmitter

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

G300A NKD-H34SG

Respiration (Thermistor Respiration Measurement)

• P901 TR-900P Respiration pickup for air flow measurement · placed at the nose · R x x x x x – – – 1applicable for spontaneous breathing patients · cable length 3.0 m

• P902 TR-910P Respiration pickup for air flow measurement · applicable for R x x x x x – – – 1artificially respirated patients · Airway adapter V911 is needed · cable length 3.0 m

• V911 YG-001P Airway adapter for respiration pickup P902 D x x x x x – – – 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

P901 P902 V911

Page 14: Catalogo Nihon Kohden

SpO 2 Measurement

14

SpO2 connection cord · page 15

Reusable SpO2 probes · page 16

Disposable SpO2 probes · page 17

( )

Page 15: Catalogo Nihon Kohden

Sp

O2

ME

AS

UR

EM

EN

T

15

SpO2 Measurement

SpO2 Connection Cord

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• K931 JL-900P SpO2 connection cord · for connecting SpO2 probes to the R x x x x x – – – 1patient monitor · with protective cap for probe connector · cable length 2.5 m

• L311 JL-302T SpO2 connection cord · for connecting SpO2 probes to the R – – – – – x – – 1patient monitor · with protective cap for probe connector · cable length 2.5 m

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

sK931 L311

1972 Development of Measurement Method for the Pulsoximetry (SpO2 Measurement)

The method for determination of arterial oxygen saturation, based on the

photoelectric plethysmography, was conceptualised and implemented in 1972 by

the Japanese bio-engineer Takuo Aoyagi (NIHON KOHDEN Corporation). This idea

came about while using an ear densitometer for recording dilution curves for dyes

(pigments). The first commercial oximeter »OLV-5100« was presented by

NIHON KOHDEN back in 1975.

This method has been used worldwide since the late 1970s and has since then

been further refined by many manufacturers.

The NIHON KOHDEN SpO2 sensors of the BluPRO®-Series are at the cutting edge

of this progressive technology.

Page 16: Catalogo Nihon Kohden

Sp

O2

ME

AS

UR

EM

EN

T

16

SpO2 Measurement

Reusable SpO2 Probes

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

• P224A TL-101T Finger probe · for adults and children with a weight of more R x x x x x – 1* – 1than 20 kg · cable length 1.6 m

• P225F TL-201T Finger probe BluPRO® series · for adults and children with a R x x x x x x 1* – 1weight of more than 20 kg · cable length 1.6 m

• P225G TL-220T Multi-site probe BluPRO® series · for adults and children with R x x x x x x 1* – 1a weight of more than 3 kg · cable length 1.6 m

• P205A TL-260T Multi-site Y probe · for neonates and infants (semi disposable) · R x x x x x x 1* – 5cable length 1.6 m

• P256 6143-012434 Ear clip for multi-site Y probe P205A (no illustration) R x x x x x x 1* – 1

• P260A 6143-011854 Sponge attachment tape S for multi-site Y probe P205A S x x x x x x 1* – 24

• P260B 6143-011863 Sponge attachment tape L for multi-site Y probe P205A S x x x x x x 1* – 24

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = see also section Accessories for Telemetry Transmitter

P224A

P225F P225G P205A

P260A P260B

Page 17: Catalogo Nihon Kohden

Sp

O2

ME

AS

UR

EM

EN

T

17

SpO2 Measurement

Disposable SpO2 Probes

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

• P201C TL-253T Disposable probe BluPRO® series for foot · for infants with a D x x x x x x 1* – 5weight of less than 3 kg · cable length 1.6 m

• P201B TL-252T Disposable probe BluPRO® series for finger or toe · for D x x x x x x 1* – 5children with a weight between 3 kg and 40 kg · cable length 1.6 m

• P201A TL-251T Disposable probe BluPRO® series for finger or toe · for adults D x x x x x x 1* – 5with a weight of more than 30 kg · cable length 1.6 m

• P229A TL-061S Disposable probe · for adults and children with a weight D x x x x x x 1* – 5between 15 kg and 50 kg (finger probe) and/or children with a weight between 3 kg and 15 kg (toe probe) · cable length 0.8 m

• P229B TL-062S Disposable probe · same as P229A, but cable length 1.6 m D x x x x x x 1* – 5

• P228A TL-051S Disposable probe · for adults with a weight more than 50 kg D x x x x x x 1* – 5(finger probe) and/or neonates with a weight less than 3 kg (foot probe) · cable length 0.8 m

• P228B TL-052S Disposable probe · same as P228A, but cable length 1.6 m D x x x x x x 1* – 5

• P259 340703 COTTONY tape for fixing the disposable probes S x x x x x x 1* – 20

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = see also section Accessories for Telemetry Transmitter

[1] P201A | [2] P201B | [3] P201C [1] P228A | P228B | [2] P229A | P229B P259

[1] [2]

BluPRO®-SpO2 Sensors

The sensors of the BluPRO® series are water tight, so you can clean them under running water or even immerse them in a soapy

alkaline or disinfectant solution (glutaraldehyde solution 2.0% or hydrochloric alkyl diaminoethylene glycine 0.5%)!

In the finger version of the sensor, the sensor upper and lower shells are mounted in parallel thus, providing, on the one hand, exact

alignment of the optical sensor components vis-à-vis one another and, on the other hand, markedly enhanced comfort during long-

term wear.

In addition, flexible lateral flaps shield out external light, thus preventing corruption of the measuring signals as a result of ad-

ditional artificial light sources!

The single-use versions place special emphasis on exact positioning of LED and photodetector. For this reason the two optical

components are designed separately and can thus be brought into precise alignment with each other by the user.

The outcome of these myriad innovative detailed solutions is more precise and more stable measurement results.

[1] [2] [3]

Page 18: Catalogo Nihon Kohden

Temperature Measurement

18

Temperature measurement · page 19

( )

Page 19: Catalogo Nihon Kohden

TE

MP

ER

AT

UR

E M

EA

SU

RE

ME

NT

19

Temperature Measurement

Temperature Measurement

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

• NKD-P240A YSI-401 Temperature sensor for adults (esophagus, rectum) · R x x x x x – – – 16.3 mm Ø miniature jack · cable length 3.5 m

• NKD-P241A YSI-402 Temperature sensor for children (esophagus, rectum) · R x x x x x – – – 16.3 mm Ø miniature jack · cable length 3.5 m

• NKD-P242A YSI-409A Temperature sensor for body surface · 6.3 mm Ø R x x x x x – – – 1miniature jack · cable length 3.5 m

• K961 JT-900P Connection cable for temperature sensors · for R – x x x x – – – 1connecting of two temperature sensors with 6.3 mm Ø miniature jacks to a multi-parameter socket · cable length 0.3 m

• NKD-P249 Probe cover for temperature sensor NKD-P240A D x x x x x – – – 10(illustration similar to NKD-P249S)

• NKD-P249S ASR618a Probe cover for temperature sensor NKD-P240A D x x x x x – – – 100

• NKD-P249M ASR618 Probe cover for temperature sensor NKD-P241A D x x x x x – – – 100(illustration similar to NKD-P249S)

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

[1] NKD-P242A | [2] NKD-P241A

[3] NKD-P240A

K961

[1]

[2]

[3]

NKD-P249S

Page 20: Catalogo Nihon Kohden

Non- invas ive B lood Pressure (NIBP)

20

Hoses · page 21

Cuffs (reusable, latex-free) · page 22

Disposable cuffs · page 23

( )

Page 21: Catalogo Nihon Kohden

NO

N-I

NV

AS

IVE

BL

OO

D P

RE

SS

UR

E

21

Non-invasive Blood Pressure (NIBP)

Hoses

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

• S901 YN-900P Hose for cuffs for adults and children · NK bayonet joint · R x x x x x – – – 1double hose system · hose length 1.5 m

• S902 YN-901P Hose for cuffs for adults and children · NK bayonet joint · R x x x x x – – – 1double hose system · hose length 3.5 m

• S904 YN-920P Hose for disposable cuffs for neonates · cone joint · double R x x x x x – – – 1hose system · hose length 1.5 m

• S905 YN-921P Hose for disposable cuffs for neonates · cone joint · double R x x x x x – – – 1hose system · hose length 3.5 m

• S929A YN-100T Hose for cuffs for adults and children · NK bayonet joint · R – – – – – x – – 1double hose system · hose length 1.5 m

• S929B YN-101T Hose for cuffs for adults and children · NK bayonet joint · R – – – – – x – – 1double hose system · hose length 3.5 m

• S930A YN-120T Hose for disposable cuffs for neonates · cone joint · double R – – – – – x – – 1hose system · hose length 1.5 m

• S930B YN-121T Hose for disposable cuffs for neonates · cone joint · double R – – – – – x – – 1hose system · hose length 3.5 m

• S903 YN-990P Extension hose · to extend the hoses S901, S902, S929A and R x x x x x x – – 1S929B with NK bayonet joint · hose length 1.5 m

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

[1] S901 | [2] S902 [1] S904 | [2] S905 S903

S929A | S929B S930A | S930B

[1][2] [2]

[1]

Page 22: Catalogo Nihon Kohden

NO

N-I

NV

AS

IVE

BL

OO

D P

RE

SS

UR

E

22

Non-invasive Blood Pressure (NIBP)

Cuffs (reusable, latex-free)

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

• S943A YP-960T Cuff for infants · width 5 cm · for circumference of 8–13 cm · R x x x x x x – – 1latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening

• S943B YP-961T Cuff for children · width 7 cm · for circumference of 12–18 cm · R x x x x x x – – 1latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening

• S943C YP-962T Cuff for children · width 10 cm · for circumference of 15–23 cm · R x x x x x x – – 1latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening

• S944B YP-963T Cuff for adults · width 13 cm · for circumference of 21–30 cm · R x x x x x x – – 1latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening

• S944C YP-964T Cuff for adults · width 15 cm · for circumference of 26–36 cm · R x x x x x x – – 1latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening

• S944D YP-965T Cuff for adults · width 19 cm · for circumference of 33–45 cm · R x x x x x x – – 1latex-free · NK bayonet joint on 15 cm connection hose · Velcro fastening

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

[1] S943A | [2] S943B | [3] S943C | [4] S944B | [5] S944C | [6] S944D

[5]

[6]

[1]

[2] [3] [4]

Page 23: Catalogo Nihon Kohden

NO

N-I

NV

AS

IVE

BL

OO

D P

RE

SS

UR

E

23

Non-invasive Blood Pressure (NIBP)

Disposable Cuffs

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

• YP-920P Cuff for neonates · width 2.5 cm · cone joint on 15 cm connection hose D x x x x x x – – 10

• YP-921P Cuff for neonates · width 3 cm · cone joint on 15 cm connection hose D x x x x x x – – 10

• YP-922P Cuff for neonates · width 4 cm · cone joint on 15 cm connection hose D x x x x x x – – 10

• YP-923P Cuff for neonates · width 5 cm · cone joint on 15 cm connection hose D x x x x x x – – 10

• YP-910P Cuff for infants · width 6 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20

• YP-912P Cuff for children · width 9 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20

• YP-913P Cuff for adults · width 12 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20

• YP-914P Cuff for adults · width 14 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20

• YP-915P Cuff for adults · width 16 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20

• YP-916P Cuff for adults · width 20 cm · NK bayonet joint on 20 cm connection hose D x x x x x x – – 20

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

[1] YP-920P | [2] YP-921P | [3] YP-922P

[4] YP-923P

[1] YP-910P | [2] YP-912P [1] YP-913P | [2] YP-914P | [3] YP-915P

[4] YP-916P

[1] [2] [3] [4] [1] [2] [1] [2] [3] [4]

Page 24: Catalogo Nihon Kohden

Invas ive B lood Pressure ( IBP)

24

Invasive Blood Pressure (IBP) · page 25

( )

Page 25: Catalogo Nihon Kohden

INV

AS

IVE

BL

OO

D P

RE

SS

UR

E

25

Invasive Blood Pressure (IBP)

Invasive Blood Pressure

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• K951 JP-900P Connection cord for invasive blood pressure · for Becton R x x x x x – – – 1Dickinson (Ohmeda) transducer (e.g. TP 400T) · cord length 3.5 m

• K952 JP-910P Connection cord for invasive blood pressure · transducer- R x x x x x – – – 1adapter cable · for Becton Dickinson (Ohmeda) transducer (e.g. P23XL-1, P10EZ-1) · cord length 0.3 m

• L901 JP-920P Connection cord for invasive blood pressure · for Baxter R x x x x x – – – 1(Edwards) transducer · cord length 3.5 m

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

K951 K952 L901

Page 26: Catalogo Nihon Kohden

Cardiac Output (CO)

26

Cardiac Output (CO) · page 27

( )

Page 27: Catalogo Nihon Kohden

CA

RD

IAC

OU

TP

UT

27

Cardiac Output (CO)

Cardiac Output

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• K962 JT-950P Connection cord for catheter and temperature measure- R – x x x x – – – 1ment (Baxter and Becton Dickinson) · cord length 2.0 m

• SP-4035-1 CO extension cable · cable length 1.0 m R – x x x x – – – 1

• NKD-SP4045 684062 Inline sensor connection cable Becton Dickinson D – x x x x – – – 1

• NKD-SP5107H 680078 Thermodilution catheter Becton Dickinson 7F · length D – x x x x – – – 51.1 m (no illustration)

• NKD-SP5107H-IS 680077 Thermodilution catheter Becton Dickinson with inline D – x x x x – – – 5sensor 7F · length 1.1 m (no illustration)

• NKD-SP4500 680000 Inline iced injectate kit with injectate sensor housing D – x x x x – – – 4(illustration similar to NKD-SP5045)

• NKD-SP4572 680178 Room temperature injectate kit with injectate sensor D – x x x x – – – 5housing (illustration similar to NKD-SP5045)

• NKD-SP5045 680006 Injectate sensor housing for inline measurement of D – x x x x – – – 25injectate temperature with sensor cable

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

K962 SP-4035-1 NKD-SP4045

NKD-SP5045

Page 28: Catalogo Nihon Kohden

Capnography

28

Main stream method · page 29 to 31

CO2 calibration gas · page 31

Side stream method · page 32

( )

Page 29: Catalogo Nihon Kohden

CA

PN

OG

RA

PH

Y

29

Capnography

Main stream Method

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• P907 TG-920P CO2 sensor kit CapONE · it includes CO2 sensor P923 and R x x x x x – – – 1CO2 adapter K984 · main stream CO2 sensor for non-intubated patients · for expiratory information · new measurement technique decreases the number of false alarms · for connection to a multi-parameter socket · includes data processing hardware · maintenance-free · cable length 3.5 m

• P923 TG-921T CO2 sensor CapONE · for non-intubated patients · for R x x x x x – – – 1expiratory information · for connection to the CO2 adapter K984 · exceptionally shockproof · cable length 1.5 m

• K984 JG-920P CO2 adapter CapONE · for non-intubated patients · for R x x x x x – – – 1expiratory information · for connection to a multi-parameter socket · includes data processing hardware · cable length2.0 m

• V921 YG-120T Disposable nasal adapter for CapONE · for expiratory D x x x x x – – – 30information · rejects condensates · short starting time of 5 s only

• V922 YG-121T Disposable nasal adapter for CapONE · for expiratory D x x x x x – – – 30information · rejects condensates

• V923 YG-122T Disposable nasal adapter with O2 tube for CapONE · for D x x x x x – – – 30expiratory information · rejects condensates · during supply of O2 with face mask or O2 tube the capnogram can be constantly displayed without any distortion

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

P907 P923 K984

V921 V922 V923

Page 30: Catalogo Nihon Kohden

CA

PN

OG

RA

PH

Y

30

Capnography

Main stream Method

• P903* TG-900P CO2 sensor kit · it includes CO2 sensor P922A and CO2 R x x x x x – – – 1adapter K981 · main stream CO2 sensor for intubated patients · for expiratory information · for connection to a multi-parameter socket · includes data processing hardware · maintenance-free · cable length 3.0 m

• P922A TG-101T CO2 sensor · for intubated patients · for expiratory infor- R x x x x x – – – 1mation · for connection to the CO2 adapter K981 · exceptionally shockproof · cable length 1.0 m

• K981 JG-900P CO2 adapter · for intubated patients · for expiratory R x x x x x – – – 1information · for connection to a multi-parameter socket · includes data processing hardware · cable length 2.0 m

• R801 YG-101T Airway adapter without heater · rejects condensates · D x x x x x – – – 50short starting time of 5 s only · 5 ml dead space volume

• P905 TG-950P CO2 sensor kit · it includes CO2 sensor P921 and CO2 R x x x x x – – – 1adapter K982 · for intubated patients · for inspiratory and expiratory information · for connection to a multi-parameter socket · includes data processing hardware · maintenance-free · cable length 4.0 m

• P921 TG-201T CO2 sensor · for intubated patients · for inspiratory and R x x x x x – – – 1expiratory information · for connection to the CO2 adapter K982 · exceptionally shockproof · cable length 2.0 m

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[*] Attention during anaesthesia! Especially during the use of closed respiration circuits (CO2 returned respiration)!

The sensor does not measure inspiratory CO2 concentrations!

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

P903 P922A K981

R801 P905 P921

Page 31: Catalogo Nihon Kohden

CA

PN

OG

RA

PH

Y

31

Capnography

Main stream Method

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

K982 [1] R802 | [2] R803

[1]

[2]

• K982 JG-950P CO2 adapter · for intubated patients · for inspiratory and R x x x x x – – – 1expiratory information · for connection to a multi-parameter socket · includes data processing hardware · cable length2.0 m

• R802 YG-201T Airway adapter without heater · for adults and children with D x x x x x – – – 30a weight of more than 10 kg · rejects condensates · short starting time of 5 s only · 5 ml dead space volume

• R803 YG-202T Airway adapter without heater · for children and neonates D x x x x x – – – 30with a weight between 3 kg and 10 kg · rejects condensates · short starting time of 5 s only · 2 ml dead space volume

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

CO2 Calibration Gas

• NKD-CO2Gas CO2 calibration gas · 200 g gas cylinder R x x x x x – – – 1

• NKD-Ventil Flow regulator S x x x x x – – – 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

NKD-CO2Gas NKD-Ventil

Page 32: Catalogo Nihon Kohden

CA

PN

OG

RA

PH

Y

32

Capnography

Side stream Method

• V907C YG-914P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube D x x x x x – – – 25for non-intubated neonates · tube length 2.5 m

• V907B YG-913P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube D x x x x x – – – 25for non-intubated children · tube length 2.5 m

• V907A YG-912P Nasal FilterLine (TM) Oridion Medical · nasal gas probe tube D x x x x x – – – 25for non-intubated adults · tube length 2.5 m

• NKD-006342 FilterLine (H) for neonates and infants · for use together with D x x x x x – – – 25humidifier · max. 72 h continuous operation · 0.5 ml dead space volume · tube length 2.0 m

• NKD-XS04624 FilterLine (H) for adults and children · for use together with D x x x x x – – – 25humidifier · max. 72 h continuous operation · 7.3 ml dead space volume · tube length 2.0 m

• NKD-XS04620 FilterLine (H) for adults and children · for use without D x x x x x – – – 25humidifier · max. 6 h continuous operation · 7.3 ml dead space volume · tube length 2.0 m

• V903F 618877 Microstream (TM) Airway adapter · for neonates and infants · D x x x x x – – – 250.5 ml dead space volume

• V903E YG-904P Microstream (TM) Airway adapter · for adults · 7.3 ml dead D x x x x x – – – 25space volume

• V901 YG-920P Exhaust gas adapter · tube length 3.0 m R x x x x x – – – 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

[1] V907A | [2] V907B | [3] V907C [1] NKD-006342 | [2] NKD-XS04624

[3] NKD-XS04620

V903F

V903E V901

[1] [2] [3] [1] [2] [3]

Page 33: Catalogo Nihon Kohden

FiO2 measurement · page 34

Measurement of anaesthetic gas · page 34 to 35

F iO 2 Measurement and Measurement of Anaesthet ic Gas

33

( )

Page 34: Catalogo Nihon Kohden

FIO

2M

EA

SU

RE

ME

NT

·

ME

AS

UR

EM

EN

T O

F A

NA

ES

TH

ET

IC G

AS

34

FiO2 Measurement · Measurement of Anaesthetic Gas

FiO2 Measurement

• P911 074705 O2 sensor · coiled cord · cable length 0.6 m R – x x x x – – – 1

• K941 JO-900P Connection cable for O2 sensor · for connection to a multi- R – x x x x – – – 1parameter socket · cable length 3.0 m

• V912 110774 T-adapter for O2 measurement (connection of the O2 sensor) D – x x x x – – – 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

sP911 K941 V912

Measurement of Anaesthetic Gas

• NKD-V915B 613721 Dryline water trap · for children and neonates R – x x – x – – – 10

• NKD-V915A 613712 Dryline water trap · for adults R – x x – x – – – 10

• NKD-V916A 613739 Dryline Airway adapter · straight D – x x – x – – – 10

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

NKD-V915B NKD-V915A NKD-V916A

Page 35: Catalogo Nihon Kohden

FIO

2M

EA

SU

RE

ME

NT

·

ME

AS

UR

EM

EN

T O

F A

NA

ES

TH

ET

IC G

AS

35

Measurement of Anaesthetic Gas

NKD-V917B NKD-V917A NKD-Scottgas

611358

• NKD-V916B 613748 Dryline Airway adapter · elbow D – x x – x – – – 10

• V903E YG-904P Microstream (TM) Airway adapter · for adults · 7.3 ml dead space volume D – x x – x – – – 25

• V903F 618877 Microstream (TM) Airway adapter · for neonates and infants · 0.5 ml dead space volume D – x x – x – – – 25

• NKD-V917B 613775 Sampling tube · for children and neonates · tube length 2.5 m D – x x – x – – – 25

• NKD-V917A 613766 Sampling tube · for adults · tube length 2.5 m D – x x – x – – – 25

• NKD-Scottgas Anaesthesia calibration gas · 1,000 ml S – x x – x – – – 1

• 611358 Flow regulator · with pressure gauge and connection tube R – x x – x – – – 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

Measurement of Anaesthetic Gas

Supp

ly C

ode

No.

NKD-V916B V903E V903F

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

Page 36: Catalogo Nihon Kohden

Dye Densi tograph

36

Dye · page 37

Sensors · page 37

( )

Page 37: Catalogo Nihon Kohden

DY

E D

EN

SIT

OG

RA

PH

37

Dye Densitograph

Dye · Sensors

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• NKD-IC-GreenP Indocyanin-green · 5 x 50 mg dye S – – – – – – – x 5

• TL-301P Finger sensor R – – – – – – – x 1

• P196 TL-321P Nose sensor R – – – – – – – x 1

• TL-351P Injection detector R – – – – – – – x 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

Supp

ly C

ode

No.

NKD-IC-GreenP [1] TL-301P | [2] P196 TL-351P

[1]

[2]

Page 38: Catalogo Nihon Kohden

Other Accessories

38

Power cable · page 39

Cleaning pen · page 39

Touch pen · page 39

Connection cable for external equipment · page 39

( )

Page 39: Catalogo Nihon Kohden

OT

HE

R A

CC

ES

SO

RIE

S

39

Other Accessories

Power Cable · Cleaning Pen · Touch Pen · Connection Cable for External Equipment

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• NKD-L936 314839B Power cable · cable length 2.5 m R x x x x x x x x 1

• Y011 404617 Cleaning pen for thermal head R x x x x x x x x 1

• Y075 577297A Touch pen for easy use of touch screen monitors · includes cord and touch pen holder R x x x x x x x – 1

• K974 515738 Connection cable for signal output of ECG and blood pressure · cable length 5.0 m R – x x – – – – – 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

Supp

ly C

ode

No.

NKD-L936 Y011 Y075

K974

Page 40: Catalogo Nihon Kohden

Batter ies

40

Batteries · page 41

Battery charger (external) · page 41

( )

Page 41: Catalogo Nihon Kohden

BA

TT

ER

IES

41

Batteries

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

Batteries · Battery Charger (external)

• X062 YS-076P5 Battery pack · 12 V, 3700 mAh · nickel metal hydride R x – – – – – – – 1(Ni-MH) · rechargeable

• X060 NKB-101 Battery pack · 12 V, 1700 mAh · nickel cadmium R – x x – – – – – 1(Ni-Cd) · rechargeable

• SB-201VK External battery charger for battery X060 R – x x – – – – – 1(no illustration)

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

Supp

ly C

ode

No.

X062 X060

Page 42: Catalogo Nihon Kohden

Recording Paper

42

Recording paper · page 43

( )

Page 43: Catalogo Nihon Kohden

RE

CO

RD

ING

PA

PE

R

43

Recording Paper

Recording Paper

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• NKD-A723 FQW50-3-100 Thermal recording paper · Z-fold book · 50 mm x 30 m S x x x x x – x x 1(each page 100 mm) · without grid

• A810 QW60-2 Thermal recording paper · roll · 60 mm x 20 m S – – – – – x – – 1(each page 100 mm) · without grid

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

BSM

-230

0 Li

fesc

ope

i/L

BSM

-410

0 Li

fesc

ope

P

BSM

-510

0 Li

fesc

ope

A

BSM

-951

0 Li

fesc

ope

M

BSM

-980

0 Li

fesc

ope

S

OPV

-150

0 Li

fesc

ope

N

WEP

-420

0/W

EP-8

400

DD

G-2

001

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Dis

posa

ble/

Reus

able

/Su

pplie

s

Supp

ly C

ode

No.

Page 44: Catalogo Nihon Kohden

Accessories for Te lemetr y Transmitter

44

ECG electrode leads · page 45

ECG electrodes · page 46 to 47

Reusable SpO2 probes · page 48

Disposable SpO2 probes · page 49

Cuffs (reusable, latex-free) · page 50

Bags · page 50

( )

Page 45: Catalogo Nihon Kohden

AC

CE

SS

OR

IES

FO

R T

EL

EM

ET

RY

TR

AN

SM

ITT

ER

45

Accessories for Telemetry Transmitter

ECG Electrode Leads

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

• K908A BR-912P Electrode lead for 2 electrodes · snap type · cable length 0.8 m R – – – x1* x1* x 1

• K907A BR-902P Electrode lead for 2 electrodes · clip type · cable length 0.8 m R – – – x1* x1* x 1

• K226 BR-019P Electrode lead for 3 electrodes · snap type · cable length 0.8 m R x – x – – – 1

• K225 BR-018P Electrode lead for 3 electrodes · clip type · cable length 0.8 m R x – x – – – 1

• K910A BR-913P Electrode lead for 3 electrodes · snap type · cable length 0.8 m R – – – x x x 1

• K911 BR-903P Electrode lead for 3 electrodes · clip type · cable length 0.8 m R – – – x x x 1

• K228 BR-021P Electrode lead for 5 electrodes · snap type · cable length 0.8 m R – x x – – – 1

• K227 BR-020P Electrode lead for 5 electrodes · clip type · cable length 0.8 m R – x x – – – 1

• K915 BR-916P Electrode lead for 6 electrodes · snap type · cable length 0.8 m R – – – x x – 1

• K912 BR-906P Electrode lead for 6 electrodes · clip type · cable length 0.8 m R – – – x x – 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = not possible for ZM-9x0 series

Dis

posa

ble/

Reus

able

/Su

pplie

s

ZB-8

10/Z

B-81

1

ZB-8

20

ZB-8

23

ZB/Z

S-91

0 ZB

/ZS/

ZM-9

20

ZB/Z

S/ZM

-930

ZS-9

40

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

[1] K908A | [2] K907A [1] K225 | [2] K226 | [3] K227 | [4] K228 [1] K910A | [2] K911

[1] K915 | [2] K912

[1] [2]

[3] [4][1] [2]

[1] [2]

[1] [2]

Page 46: Catalogo Nihon Kohden

AC

CE

SS

OR

IES

FO

R T

EL

EM

ET

RY

TR

AN

SM

ITT

ER

46

Accessories for Telemetry Transmitter

ECG Electrodes

• G217 D-90 Vitrode D · disposable ECG electrode · electrode material: Ag/AgCl · D x x x x x x 30 x 3size: ca. 55 mm dia · applicable for X-ray, CT and MRT · adhesive by patent pending electrode structure (2-dimensional elastic for tension) · very kind to the skin · suitable for long term measurements (> 72 h) · wash-, shower- and bath-steadily · for universal use

• G207 L-150X Vitrode L · disposable ECG electrode · electrode material: Ag/AgCl · D x x x x x x 5 x 30size: ca. 35 mm dia · applicable for X-ray, CT and MRT · strong adhesive · resistant against detachment by solvents · foam tape · for universal use

• G210C F-150S Vitrode F · disposable ECG electrode (small) · electrode material: Ag/AgCl · D x x x x x x 50 x 3size: ca.18 mm x 36 mm · cotton tape · electrically conductive adhesive gel · repeatedly positionable · very kind to the skin · very suitable for children · not for use in operating rooms

• G210D F-150M Vitrode F · disposable ECG electrode (medium) · electrode material: D x x x x x x 50 x 3Ag/AgCl · size: ca. 25 mm x 45 mm · cotton tape · electrically conductive adhesive gel · repeatedly positionable · very kind to the skin · not for use in operating rooms

• G201 Bs-150 Vitrode Bs · disposable ECG electrode · electrode material: Ag/AgCl · D x x x x x x 30 x 5size: ca. 47 mm x 47 mm · soft breathing cotton tape with an elastic quality for tension · hydro gel for low electrode impedance and stable measurements even on dry skin · for universal use

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = suppliesD

ispo

sabl

e/Re

usab

le/

Supp

lies

ZB-8

10/Z

B-81

1

ZB-8

20

ZB-8

23

ZB/Z

S-91

0 ZB

/ZS/

ZM-9

20

ZB/Z

S/ZM

-930

ZS-9

40

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

G217 G207 G210C

G210D G201

Page 47: Catalogo Nihon Kohden

AC

CE

SS

OR

IES

FO

R T

EL

EM

ET

RY

TR

AN

SM

ITT

ER

47

Accessories for Telemetry Transmitter

ECG Electrodes

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

G204

• G204 C-150 Vitrode C · disposable ECG electrode · electrode material: Ag/AgCl · D x x x x x x 30 x 5size: ca. 47 mm x 47 mm · soft breathing cotton tape with an elastic quality for tension · hydro gel for low electrode impedance and stable measurements even on dry skin · the electrode gel is nearly removed after removing the electrode · for universal use

• G250 J-150 Vitrode J · disposable ECG electrode · electrode material: Ag/AgCl · D x x x x x x 30 x 5size: ca. 40 mm dia · foam tape with excellent adhesive advantages even by effects of sweat or solvents · hydro gel for low electrode impedance and stablemeasurements even on dry skin · the electrode gel is nearly removed after removing the electrode · for universal use

• NKD-H34SG Disposable ECG electrode ARBO® · size: ca. 45 mm dia · applicable for X-ray, D x x x x x x 30CT and MRT · hydro gel · very strong adhesive · 72 h endurance test · shower- and wash-steadily · with skin remover

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

Dis

posa

ble/

Reus

able

/Su

pplie

s

ZB-8

10/Z

B-81

1

ZB-8

20

ZB-8

23

ZB/Z

S-91

0 ZB

/ZS/

ZM-9

20

ZB/Z

S/ZM

-930

ZS-9

40

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

G250 NKD-H34SG

Page 48: Catalogo Nihon Kohden

AC

CE

SS

OR

IES

FO

R T

EL

EM

ET

RY

TR

AN

SM

ITT

ER

48

Accessories for Telemetry Transmitter

Reusable SpO2 Probes

• P224A TL-101T Finger probe · for adults and children with a weight of more than 20 kg · R – – – – x 1* 1cable length 1.6 m

• P225F TL-201T Finger probe BluPRO® series · for adults and children with a weight of R – – – – x 1* 1more than 20 kg · cable length 1.6 m

• P225G TL-220T Multi-site probe BluPRO® series · for adults and children with a weight of R – – – – x 1* 1more than 3 kg · cable length 1.6 m

• P225H TL-201T Finger probe BluPRO® series · same as P225F, but cable length 0.6 m R – – – – – x 1(illustration similar to P225F)

• P205A TL-260T Multi-site Y probe · for neonates and infants (semi disposable) · cable R – – – – x 1* 5length 1.6 m

• P256 6143-012434 Ear clip for multi-site Y probe P205A (no illustration) R – – – – x 1* 1

• P260A 6143-011854 Sponge attachment tape S for multi-site Y probe P205A R – – – – x 1* 24

• P260B 6143-011863 Sponge attachment tape L for multi-site Y probe P205A R – – – – x 1* 24

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = because of cable length, fit for limited use

Dis

posa

ble/

Reus

able

/Su

pplie

s

ZB-8

10/Z

B-81

1

ZB-8

20

ZB-8

23

ZB/Z

S-91

0 ZB

/ZS/

ZM-9

20

ZB/Z

S/ZM

-930

ZS-9

40

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

P224A

P225F P225G P205A

P260A P260B

Page 49: Catalogo Nihon Kohden

AC

CE

SS

OR

IES

FO

R T

EL

EM

ET

RY

TR

AN

SM

ITT

ER

49

Accessories for Telemetry Transmitter

Disposable SpO2 Probes

Disposable accessories can be used only once. Do not use disposable accessories repeatedly!

P259

• P201C TL-253T Disposable probe BluPRO® series for foot · for infants with a weight of less D – – – – x 1* 5than 3 kg · cable length 1.6 m

• P201B TL-252T Disposable probe BluPRO® series for finger or toe · for children with a weight D – – – – x 1* 5between 3 kg and 40 kg · cable length 1.6 m

• P201A TL-251T Disposable probe BluPRO® series for finger or toe · for adults with a weight of D – – – – x 1* 5more than 30 kg · cable length 1.6 m

• P229A TL-061S Disposable probe · for adults and children with a weight between 15 kg and D – – – – x 1* 550 kg (finger probe) and/or children with a weight between 3 kg and 15 kg (toe probe) · cable length 0.8 m

• P229B TL-062S Disposable probe · same as P229A, but cable length 1.6 m D – – – – x 1* 5

• P228A TL-051S Disposable probe · for adults with a weight more than 50 kg (finger probe) D – – – – x 1* 5and/or neonates with a weight less than 3 kg (foot probe) · cable length 0.8 m

• P228B TL-052S Disposable probe · same as P228A, but cable length 1.6 m D – – – – x 1* 5

• P259 340703 COTTONY tape for fixing the disposable probes R – – – – x x 20

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies[1*] = because of cable length, fit for limited use

Dis

posa

ble/

Reus

able

/Su

pplie

s

ZB-8

10/Z

B-81

1

ZB-8

20

ZB-8

23

ZB/Z

S-91

0 ZB

/ZS/

ZM-9

20

ZB/Z

S/ZM

-930

ZS-9

40

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

[1] P201A | [2] P201B | [3] P201C [1] P228A | P228B | [2] P229A | P229B

[1] [2]

[1] [2] [3]

Page 50: Catalogo Nihon Kohden

AC

CE

SS

OR

IES

FO

R T

EL

EM

ET

RY

TR

AN

SM

ITT

ER

50

Accessories for Telemetry Transmitter

Cuffs (reusable, latex-free)

• S938B YP-943P Cuff for adults · width 13 cm · for circumference of 21–30 cm · latex-free · R – – – – – x 1NK bayonet joint on connection hose (no illustration)

• S938C YP-944P Cuff for adults · width 15 cm · for circumference of 26–36 cm · latex-free · R – – – – – x 1NK bayonet joint on connection hose (no illustration)

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

Dis

posa

ble/

Reus

able

/Su

pplie

s

ZB-8

10/Z

B-81

1

ZB-8

20

ZB-8

23

ZB/Z

S-91

0 ZB

/ZS/

ZM-9

20

ZB/Z

S/ZM

-930

ZS-9

40

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Bags

Dis

posa

ble/

Reus

able

/Su

pplie

s

ZB-8

10/Z

B-81

1

ZB-8

20

ZB-8

23

ZB/Z

S-91

0 ZB

/ZS/

ZM-9

20

ZB/Z

S/ZM

-930

ZS-9

40

Qua

ntit

y

Des

crip

tion

Art

icle

No.

Supp

ly C

ode

No.

Y264E NKD-Tasche1

• Y264E Disposable transportation bag for telemetry transmitter · with belt D x x x x – – 3

• NKD-Tasche Transportation bag for telemetry transmitter · with belt (illustration similar as R x x x x – – 1NKD-Tasche1)

• NKD-Tasche1 Transportation bag for telemetry transmitter · with belt R – – – – x – 1

• Y236 Shoulder strap (no illustration) R – – – – – x 1

[x] = applicable, [-] = non-applicable, [D] = disposable, [R] = reusable, [S] = supplies

Page 51: Catalogo Nihon Kohden

General Warranty Regulations

NIHON KOHDEN offers a one-year warranty for their products against material

defects and functional breakdowns starting from the day of delivery.

Excluded from this warranty are consumable materials such as recorder paper,

ink and batteries. NIHON KOHDEN products in which a defect occurs during this

warranty period will be repaired or replaced by NIHON KOHDEN customer

services or will be repaired or replaced by the authorised specialist dealer, pro-

vided that the products were used in accordance with the instructions given in

the Operating Instructions.

No other persons or organisations are authorised to grant a warranty or enter

into obligations for our products. NIHON KOHDEN does not recognise any other

form of warranty, whether implicit or in writing.

The warranty claim expires as soon as servicing measures, technical modifica-

tions or other product changes are carried out by personnel not authorised by

NIHON KOHDEN or without the explicit agreement of NIHON KOHDEN.

Furthermore, the warranty claim expires in the event of unauthorised opening

of the device, of re-installation or repair by personnel not authorised by

NIHON KOHDEN as well as in the event of removal of the rating plates, in the

event of damage resulting from negligence, the use of force, or in the event of

damage caused by fire, lightning, water, vandalism, force majeure or improper

installation or use.

Warranty for reusable SpO2 sensors

The warranty period granted by NIHON KOHDEN for SpO2 sensor materials and

workmanship ends 6 months after opening the packaging, but by the latest 12

months after delivery. NIHON KOHDEN or its authorised specialist dealer will

repair or replace defective sensors provided that they have been used in

accordance with the Instructions for Use.

Please also observe our General Sales, Delivery and Payment Conditions!

Despite the meticulous care taken in compiling the information for this

Catalogue of Accessories, we cannot unfortunately rule out errors or

mistakes!

51

Warranty

Page 52: Catalogo Nihon Kohden

Remarks

Customer Number:

Device Type Designation Serial Number

52

(By quoting your customer number you will particularly help us to expedite processing of your order.)

Page 53: Catalogo Nihon Kohden

Supply Code No. Page611358 356124-039432 10A810 43G201 11, 46G204 11, 47G207 11, 46G210C 11, 46G210D 11, 46G217 11, 46G250 12, 47G271A 12G271K 12G272A 12G272B 12G272C 12G300A 13K225 45K226 45K227 45K228 45K901 10K907A 45K908A 45K910A 10, 45K911 10, 45K912 10, 45K915 10, 45K921 10K922 10K931 15K941 34K951 25K952 25K961 19K962 27K974 39K981 30K982 31K984 29L060 10L311 15L901 25NKD-006342 32NKD-A723 43NKD-CO2Gas 31NKD-H34SG 13, 47NKD-IC-GreenP 37NKD-L936 39NKD-P240A 19NKD-P241A 19

Supply Code No. PageNKD-P242A 19NKD-P249 19NKD-P249S 19NKD-P249M 19NKD-Scottgas 35NKD-SP4045 27NKD-SP4500 27NKD-SP4572 27NKD-SP5045 27NKD-SP5107H 27NKD-SP5107H-IS 27NKD-Tasche 50NKD-Tasche1 50NKD-V915A 34NKD-V915B 34NKD-V916A 34NKD-V916B 35NKD-V917A 35NKD-V917B 35NKD-Ventil 31NKD-XS04620 32NKD-XS04624 32P196 37P201A 17, 49P201B 17, 49P201C 17, 49P205A 16, 48P224A 16, 48P225F 16, 48P225G 16, 48P225H 48P228A 17, 49P228B 17, 49P229A 17, 49P229B 17, 49P256 16, 48P259 17, 49P260A 16, 48P260B 16, 48P901 13P902 13P903 30P905 30P907 29P911 34P921 30P922A 30P923 29R801 30R802 31

Supply Code No. PageR803 31S901 21S902 21S903 21S904 21S905 21S929A 21S929B 21S930A 21S930B 21S938B 50S938C 50S943A 22S943B 22S943C 22S944B 22S944C 22S944D 22SB-201VK 41SP-4035-1 27TL-301P 37TL-351P 37V901 32V903E 32, 35V903F 32, 35V907A 32V907B 32V907C 32V911 13V912 34V921 29V922 29V923 29X060 41X062 41Y011 39Y075 39Y236 50Y264E 50YP-910P 23YP-912P 23YP-913P 23YP-914P 23YP-915P 23YP-916P 23YP-920P 23YP-921P 23YP-922P 23YP-923P 23

53

Index as per Supply Code No.

Page 54: Catalogo Nihon Kohden

Index as per Article No.

54

Article No. Page074705 34110774 34314839B 39340703 17, 49404617 39515738 39577297A 39613712 34613721 34613739 34613748 35613766 35613775 356143-011854 16, 486143-011863 16, 486143-012434 16, 48618877 32, 35680000 27680006 27680077 27680078 27680178 27684062 27ASR618 19ASR618a 19BJ-900P 10BR-018P 45BR-019P 45BR-020P 45BR-021P 45BR-902P 45BR-903P 10, 45BR-906P 10, 45BR-912P 45BR-913P 10, 45BR-916P 10, 45Bs-150 11, 46C-150 11, 47D-90 11, 46F-150M 11, 46F-150S 11, 46FQW50-3-100 43J-150 12, 47JC-103T 10JC-900P 10JC-906P 10JG-900P 30JG-920P 29JG-950P 31JL-302T 15

Article No. PageJL-900P 15JO-900P 34JP-900P 25JP-910P 25JP-920P 25JT-900P 19JT-950P 27L-150X 11, 46N-03IS3 13NKB-101 41QW60-2 43TG-101T 30TG-201T 30TG-900P 30TG-920P 29TG-921T 29TG-950P 30TL-051S 17, 49TL-052S 17, 49TL-061S 17, 49TL-062S 17, 49TL-101T 16, 48TL-201T 16, 48TL-220T 16, 48TL-251T 17, 49TL-252T 17, 49TL-253T 17, 49TL-260T 16, 48TL-321P 37TR-900P 13TR-910P 13V-040M4 12V-060M6 12V-090M3 12V-120S3 12V-120SK 12YG-001P 13YG-101T 30YG-120T 29YG-121T 29YG-122T 29YG-201T 31YG-202T 31YG-904P 32, 35YG-912P 32YG-913P 32YG-914P 32YG-920P 32YN-100T 21YN-101T 21

Article No. PageYN-120T 21YN-121T 21YN-900P 21YN-901P 21YN-920P 21YN-921P 21YN-990P 21YP-943P 50YP-944P 50YP-960T 22YP-961T 22YP-962T 22YP-963T 22YP-964T 22YP-965T 22YS-076P5 41YSI-401 19YSI-402 19YSI-409A 19

Page 55: Catalogo Nihon Kohden
Page 56: Catalogo Nihon Kohden

NIHON KOHDEN EUROPE GmbH

Raiffeisenstraße 10

D-61191 Rosbach (Germany)

Telephone: + 49 (0) 60 03/8 27-0

Telefax: + 49 (0) 60 03/8 27-599

E-Mail: [email protected]

www.nihonkohden.com

N E U R O L O G Y C A R D I O L O G Y P A T I E N T M O N I T O R I N G

Dealer

PMS-

Z-e-

01/0

5Vo

l. 1

first

art

// G

ieße

n