    AmerTexR-Serie

    Exclusive bondingtechnology provides

    cleaner air Low resistance to airflow

    High dust holdingcapacity

    Available in syntheticand natural executions

    Washable

    R-series air filter media is made ofsynthetic fibres, except type R20Natural, which is made of natural fibres.An exclusive bonding technologyensures a high number of fibres persquare metre for a given weight.

    All AmerTex R series media is whitecoloured. No colour pigments are

    needed to create a distinction betweenthe various media. The name of eachproduct together with its classificationaccording to EN779 is printed atregular intervals on the air leaving sideof each media roll, permitting easyproduct identification. R-Series media ischaracterized by a relatively lowresistance to airflow and a high dustholding capacity.

    Applications

    Synthetic filter media.

    The R15 Economy and R17 Durablemedia are recommended for use in lowpressure forced air convectors, windowventilation units, fan coils and asprefilter in paintspray cabins.

    The R29 Standard media is for use in

    room air conditioning units, hot airgenerators, air conditioning installations,home kitchen hoods and as prefilter inpaint spray cabins.

    The R50 Super media is suitable for usein air conditioning installations in thefood industry, kitchen hoods, industrialventilation systems and as prefilter inpaintspray cabins.

    Natural filter media

    The R20 Natural media, consisting oflatex coated natural fibres structuredinto a porous and dense media, isrecommended for use in severeoperating conditions.

    CleaningTypes R15 and R29 are washable to a

    limited extent. Types R17, R50 and R20are fully washable.The R-series media can be cleaned: in warm water (30 - 40C) with

    addition of a household detergent,if necessary. Drying should be doneon a flat surface. Do not rub orwring.

    by blowing with compressed air inopposite direction of filter airflow.

    Synthetic and natural filter media

    B E T T E R A I R I S O U R B U S I N E S S

  • 5/24/2018 CatalogAAF

    2/38

    AmerTexR-Serie

    RA-2-504-IN-4-0198

    Technical Data

    Type R15 Economy R17 Durable R29 Standard R50 Super R20* (30 mm)

    Recommended face velocity (m/s) 1.5 1.5 1.5 1.5 2.0

    Rated capacity (m3/h/m2) 5400 5400 5400 5400 7200

    Rated initial resistance (Pa) 17 17 26 42 80

    Recommended final resistance (Pa) 130 130 200 200 250

    Average arrestance (%) 75 - 80 75 - 80 80 - 85 87 - 92 80

    EN 779 classification G 2 G 2 G 3 G 4 G 3

    Roll size (m) 2 x 20 2 x 20 2 x 20 2 x 20 Pads only

    1 x 20 1 x 20 1 x 20 1 x 20

    Packing polyethylene bags

    Media colour white white white white brownFlame retardancy according to DIN 53438 F1 F1 F1 F1 -

    Max. operating temperature (C) 100 100 100 100 65

    Washability limited good limited good good

    * R20 media is also available in 20, 40 and 50 mm thicknesses

    Airflow Resistance

    0 1.0 2.0 3.0 4.00

    10

    30

    50

    20

    6070

    80

    40

    R 17, R15

    R 29

    R 50R 20

    Face Velocity (m/s)

    InitialResistance

    (Pa)

    1998 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.:+ 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    3/38

    AmWash

    Pleated Washable Filter

    Washable

    High dust holding capacity and long service life

    Reduce the risk of fire

    Low initial resistance

    Lightweight and easy to install

    Choice of media in the classification range G3 to F5 (EN779)

    AmWash is special ly designed for application in industrial and

    commercial heating, ventilation and air conditioning systems. For

    example like:

    AmWash is a lightweight panel filter with several special features

    like reusable aluminum steel frame, made of synthetic fiber and

    characterized by a relatively low resistance to airflow, reduce risk of

    fire, washable and easy to install. Filter media with the thickness of10mm and 20mm ensure high dust holding capacity.

    Advantages

    AmWash is available with 3 classif ications: G3, F4 and F5 in

    accordance with EN779.

    Choice of Media

    Owing to the excellent dust holding capacity, AmWash can be used

    as prefilter to higher efficiency filters or as main filters. As prefilter,

    AmWash protect more expensive main filters from prematurereplacement while as main filter it improves the quality of indoor air.

    High dust holding capacity

    Easy to install

    AmWash has a sturdy, long lasting galvanized steel frame whichoffers great resistance in harsh operating conditions. Due to its light

    weight and compact size (only 46mm depth), it is relatively

    inexpensive to ship and easy to handle and install. If required,

    AmWash can be supplied with a stainless steel or aluminum frame

    and can be manufactured to any size.

    Cleanable

    AmWash can be blow cleaned with compressed air, but only once

    or twice during its natural lifetime. AmWash can also be cleaned

    with a solution of water and detergent on a limited basis.

    Aluminum frame

    Filter media

    Supporting grid

    1) Offices, convention centers, meeting rooms, hospitals,

    shopping malls, sport centers, airports and other buildings

    with HVAC systems.

    2) Normal industrial area with central air ventilation system.

    3) Prefilter for central ventilation system for CleanRoom.

  • 5/24/2018 CatalogAAF

    4/38

    AmWash

    Tel: 03-5569 2633 / Fax: 03-5569 3633

    No. 9 (Lot 136), Jalan Juru Ukur U1/19,Hicom-Glenmarie Industrial Park, 40150Shah Alam, Selangor Darul Ehsan, Malaysia.www.aafasia.com

    ISO-9001 Certified Firm

    2006 AAF MalaysiaAMWASH-01-MAL/OCT 06

    AAF has a policy of continuous product researchand improvement and reserves the right to change

    design and specifications without notice.

    Product Information

    Technical Specification

    G3

    G3

    G3

    G3

    G4

    610 x 610 x 51

    305 x 610 x 51

    610 x 610 x 102

    305 x 610 x 102

    610 x 610 x 51

    65

    65

    55

    55

    85

    G4 305 x 610 x 51 85

    G4 610 x 610 x 102 80

    G4 305 x 610 x 102 80

    90

    90

    75

    75

    110

    110

    105

    105

    35

    35

    30

    30

    50

    50

    45

    45

    Class70% 100% 120%

    Nominal Size

    WxHxD (mm)

    595 x 595 x 46

    290 x 595 x 46

    595 x 595 x 96

    290 x 595 x 96

    595 x 595 x 46

    290 x 595 x 46

    595 x 595 x 96

    290 x 595 x 96

    Actual Size

    WxHxD (mm)

    3400

    1700

    3400

    1700

    3400

    1700

    3400

    1700

    Rated Airflow

    Capacity (m3/h)

    Initial Resistance (Pa)via Rated Airflow

    Maximum Operating Temperature : 93C (200F)Media : Synthetic fiber

    Support grid : Wire grid

    Frame :

    Corner bracket :

    Aluminum Frame

    Rigid steel bracket

    Airflow Resistance

    Face Velocity, (m/s)

    0

    25

    50

    75

    100

    170

    120

    200

    150

    0 1 2 3 4 5

    InitialResistance(Pa)

    Initial Resistance vs Face Velocity

  • 5/24/2018 CatalogAAF

    5/38

    AmAir 300

    B E T T E R A I R I S O U R B U S I N E S S

    High Quality Prefilters

    Excellent media perfor-mance in high humidity

    conditions High tensile strength

    media

    Environment-friendlymaterials

    Sturdy, reliableconstruction

    High performance, environment

    friendly media

    With the new AmAir 100 and 300series of prefilters AAF has risen tothe challenge of designing anenvironment-friendly product withthe necessary performance charac-teristics built-in. These filters feature

    a new 100% synthetic media packwhich provides excellent perfor-mance in conditions of high relativehumidity and moisture. When themedia becomes wet, resistance mayrise temporarily only to subside whenthe media starts to dry. The syntheticmedia displays great tensile strength,reducing the chance of damageduring handling and operation. Themedia is environment and user

    friendly: it does not contain anyharsh resins or artificial colouring. Itcan therefore be readily disposed ofby landfill or incineration.

    Sturdy, reliable construction

    The pleated media pack of bothrange of filters is housed within a

    sturdy double walled, die cut box,beverage board frame. To ensure themedia pack does not rack ordeteriorate under difficult operatingconditions, it is bonded to the insideof its frame at all points of contactand retained in position by retainersat the air leaving and air enteringsides. On the air leaving side of themedia pack a wiremesh pleat supportgrid maintains equidistant spacing

    between pleats, ensuring that dust iscollected evenly over the entiresurface of the media. Media usage ismaximized resulting in a moregradual rise in resistance, which inturn has a positive effect on energyconsumption and service life.

    ApplicationsClassified G4 in accordance withEN 779, AmAir 100 and 300 areideal for protecting more expensivesecondary air filters from prematuredust loading and replacement. Asprimary filters, they will also helpreduce HVAC maintenance costs bypreventing unnecessary dust build-upon coils, fans and duct work.

  • 5/24/2018 CatalogAAF

    6/38

    AmAir 300

    RA-2-509-IN-1-0798 1998 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice

    Fire Classification:a) Both filters are Class 2 approved and listed according to UL Standard 900.b) PET media is classified M2 according to NF P92-503, 504 and 505.

    Standard Dimensions Airflow Resistance

    Nominal Size1,3)

    (inches)

    W x H

    12 x 24

    16 x 20

    16 x 25

    20 x 20

    20 x 25

    24 x 18

    24 x 2024 x 24

    141/2 x 263/4

    Actual Size2,3)

    (mm)

    W x H

    290 x 595

    392 x 494

    392 x 621

    494 x 494

    494 x 621

    595 x 445

    595 x 494595 x 595

    355 x 665

    Airflow

    at 2.5 m/s

    (m3/h)

    1700

    1870

    2380

    2380

    2975

    2550

    28503400

    2260

    Notes:

    1) Width and height dimensions are interchangeable.Filters may be installed with the pleats in thevertical or horizontal position. The pleats are alwaysparallel to the longest cell side unless explicityspecified otherwise.

    2) Other sizes and air fi lters in 21 mm (1 inchnominal) depth are available upon request.

    3) See Technical Data Table for filter depths.

    Technical Data

    Type 100 - 2 100 - 4 300 - 2 300 - 4Actual Depth (mm) 48 95 48 95

    Rated Face Velocity (m/s) 1.5 - 2.5 1.5 - 3.2 1.5 - 2.5 1.5 - 3.2

    Average Arrestance1) (%) 90 - 95 90 - 95 90 - 95 90 - 95

    Efficiency1) (%) - - - -

    EN779 Classification G4 G4 G4 G4

    Rated Initial Resistance1) (Pa) 45 - 85 40 - 100 33 - 76 31 - 91

    Recomm. Final Resistance2) (Pa) 250 250 250 250

    Temperature Limits (C) 90 90 90 90

    (continuous operation)

    1) All data based on EN779.2) Recommended final resistance not to be exceeded.

    1.0 1.5 2.0 2.5 3.0 3.200

    20

    60

    100

    40

    120

    140

    160

    80

    1. AmAir 300 (48 mm), 2. AmAir 300 (95 mm)

    1.

    2.

    Rated Velocity (m/s)

    InitialResistance(Pa)

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm(S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    7/38

    DriPak 2000

    Filter classes F5 - F8 forapplications requiring

    cleaner air Mechanically strong with

    a high abrasionalresistance

    Operational reliability inhigh airflow and highdust loading conditions

    Excellent performance inhigh moisture conditions

    Mechanically Strong and RobustDriPak 2000 pocket filters are made ofhigh quality synthetic media. They arerenowned for their high performancecharacteristics in applications requiring ahigh dust holding capacity and higher aircleaning capacity. Built from strong,robust materials they display excellentabrasional resistance and perform well in

    100% relative humidity and in highairflow and heavy dust loadingconditions. Since their introduction theyhave proven a resounding success with thepharmaceutical, food processing andautomotive industries.

    Microfine Synthetic FibresProvide Cleaner AirDriPak 2000 pocket media comprises aunique matrix of primary and secondary

    synthetic fibres with a thin layer of highstrength spunbond scrim on the airleaving side to increase filter stability andprevent particle migration. This dualmedia design ensures a low initial pressuredrop, a high dust holding capacity and along filter service life.

    Efficiency Ranges

    DriPak 2000 is available in fourefficiencies. For easy identification, eachefficiency has its own colour coded mediascheme:

    Final ResistanceDriPak 2000 filters are tested inaccordance with EN779. Therecommended final resistance is 450 Pa.

    Temperature limitsDriPak 2000 synthetic filters are designedfor a continuous operating temperatureup to 70C. The filters should not be

    stored or transported in conditions wheretemperatures exceed 60C.

    B E T T E R A I R I S O U R B U S I N E S S

    Superfine Synthetic Fibres Provide Cleaner Air

    Efficiency EN 779 Media Colour

    90 - 95% F8 Yellow

    80 - 85% F7 Red

    60 - 65% F6 Green

  • 5/24/2018 CatalogAAF

    8/38

    DriPak 2000

    RA-2-542-IN-2-0999 1999 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    0 1.00.5 1.5 2.0 2.5 3.00

    50

    25

    75

    100

    125

    200

    225

    150

    175

    DriPak 2000 90%

    0 1.00.5 1.5 2.0 2.5 3.00

    50

    25

    75

    100

    125

    200

    225

    150

    175

    DriPak 2000 80%

    0 1.00.5 1.5 2.0 2.5 3.00

    30

    60

    120

    90

    DriPak 2000 60%

    0 1.00.5 1.5 2.0 2.5 3.00

    30

    60

    120

    90

    DriPak 2000 50%

    Notes:1) Filters can be operated at 67% to 133% of rated face velocity.2) All performance data based on EN779 1993 standard (ASHRAE 52.1-1992 test method).3) The recommended final resistance is 450 Pa.4) The DriPak 2000 filter sizes fit into frame sizes 610 x 610, 305 x 610 and 508 x 610 mm.5) Filters are also available in other sizes and with 25 and 20 mm headers.

    3.2

    2.5

    1.25

    592x592x700287x592x700490x592x700592x592x635287x592x635490x592x635592x592x508287x592x508490x592x508

    947846635

    8.03.66.26.73.35.04.12.03.4

    4250212535503400170028501700850

    1400

    160160160135135135909090

    RatedFaceVelocity1)

    (m/s)

    ActualSize4/5)

    (wxhxd)(mm)

    NumberofPockets

    GrossMediaArea(m2)

    RatedAirflowCapacity(m3/h)

    RatedInitial2/3)

    Resistance(Pa)

    90-95% Average Efficiency2) - F 8

    80-85% Average Efficiency2) - F 7

    60-65% Average Efficiency2) - F 6

    3.2

    2.5

    1.25

    592x592x700287x592x700490x592x700592x592x635287x592x635490x592x635592x592x508287x592x508490x592x508

    947846635

    8.03.66.26.73.35.04.12.03.4

    4250212535503400170028501700850

    1400

    105105105808080606060

    3.2

    2.5

    592x592x700287x592x700

    490x592x700592x592x635287x592x635490x592x635

    94

    7846

    8.03.6

    6.26.73.35.0

    42502125

    3550340017002850

    7575

    75656565

    2.5

    2.5

    2.5

    592x592x635287x592x635490x592x635592x592x508287x592x508490x592x508592x592x305287x592x305490x592x305

    635635635

    5.02.54.34.12.03.42.51.22.0

    340017002850340017002850340017002850

    555555606060656565

    50-55% Average Efficiency2) - F 5

    Resistance Curves and Selection Chart Data

    InitialResistance(Pa)

    InitialResistan

    ce(Pa)

    InitialR

    esistance(Pa)

    InitialResistance(Pa)

    Face Velocity (m/s)

    Face Velocity (m/s)

    Face Velocity (m/s)

    Face Velocity (m/s)

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    9/38

    VariCel

    High and Medium Efficiency

    Extended SurfaceSupported Pleat Air Filters

    VariCel

    with Intersept

    IAQ Engineered Media Treatedwith Intersept Antimicrobial

  • 5/24/2018 CatalogAAF

    10/38

    High Temp Series VariCel filters are designed for sys-tems operating from 350 -900 F. Constructed of alu-minized steel, High Temperature VariCel filters offer

    rated efficiency with proven reliability over the life of the filter.

    See page 4 for models and temperature limits.Type NH Series VariCel filters are designed for specialsizes and applications, including incineration andcompaction disposal systems. Manufactured of fire-

    retardant, 34" thick, heavy wall particle board, Type NH VariCelfilters (U.L. Class 1) are operable at temperatures up to 200F.The filters are constructed without headers and cell sides areflush with front face dimensions.

    VariCel andVariCel withIntersept

    Extended SurfaceSupported Pleat Filters

    Available In Three Efficiencies 90-95% (MERV 14),80-85% (MERV 13), 60-65% (MERV 11)

    Available with Intersept in 90-95% & 60-65%efficiency

    U.L. Class 1

    Ideal For Difficult Operating Conditions

    - Var iable a i r vo lume

    - Turbulent ai rf low

    - Repeated fan shutdown

    - High temperature operat ion

    - Hi gh humi di ty

    - Intermittent exposure to watersuch as seacoast installations

    VariCel filters with Intersept antimicrobial are designed specifical-

    ly to improve Indoor Air Quality (IAQ). Air filters are designed totrap and concentrate particulate air contaminants including viablefungal and bacterial spores. The presence of Intersept antimico-bial preservative in the filter media is intended to preserve the in-tegrity of the media throughout the useful life of the filter.Antimicrobial preservatives are not meant to increase the efficiencyof the filter, nor to kill microorganisms "on the fly" as they passthrough a filter. Intersept is EPA registered and environmentallysafe.

    Engineered For A Variety Of Applications

    Designed To Improve Indoor Air Quality

    Type SH Single Header VariCel filters are designed forsystems originally supplied by AAF International. A

    unique 1316" flanged header on the air entering side al-lows the filter to be easily inserted and latched into front andside access systems.

    Type DH Double Header VariCel filters are designed toupgrade air cleaning performance and reliability. Two1316" thick flanged headers make the filters compatible

    with the holding frames and latching devices of various manu-facturers, including rear access systems.

    XL Series VariCel filters, single header (XL-S) and double header(XL-D), contain up to 67% more media and offer more than twice theservice life of standard single and double header models.

  • 5/24/2018 CatalogAAF

    11/38

    Corrugated Aluminum Separators

    with Rolled Edges maintain uniform

    pleat spacing for optim um airflow. The

    separators are rolled to eliminate

    sharp edges, preventing m edia dam-

    age during shipping and personal in-ju ry du rin g i ns tall ati on .

    Crimped Rear Flanges (SH) are rolled

    over and riveted to add strength, elimi-

    nate sharp edges, and prevent bypassleakage.

    Media Pack Restraint

    Steel brace on air leaving

    side adds support to th e

    media pack.

    Media Pack Sealant A layer

    of high efficiency media seals the

    media pack into the cell sides.

    The media sealant prevents by-

    pass leakage and damage to the

    media and separators during

    shipping and handling. By allow-

    ing slight movement of th e media

    pack when the filter is jarred, the

    cushioning sealant helps prevent

    tears and punctur es to the m edia.

    VariCel media is manufacturedwith two layers of glass fibers:coarser fibers on the air enteringside and finer fibers on the airleaving side.

    Our dual density design allows

    dirt particles to be collectedthroughout the entire depth ofthe filter utilizing the full clean-ing potential of the media. Maximum dust holding capacity ex-tends the life of the filter, minimizing operating costs.

    The water resistant media can withstand intermittent exposure towater, making VariCel filters ideal for installations in humid areasor where the filters are exposed to moisture.

    DUAL DENSITY MEDIAREDUCES OPERATING COSTS

    FINER FIBERSAir leaving side

    COARSE FIBERS Air entering side

    AIRFLOW

    VariCel's rigid constructionwith supported pleat mediapack maintains a compact,unitized structure even undertough operating conditions.Variable air velocity and re-peated fan shutdown do not

    compromise performance.

    Unitized Construction

    Interlocked header and cellsides, along the entire lengthof each side, provide maxi-mum sealing. Competitive fil-ters are designed with loosefitting headers which allowgreater potential for bypassleakage.

    BUILT RUGGED FOR DEPENDABLE PERFORMANCE

    Pleats and Separators

    Bonded For Strength

    During the pleating process,

    spots of glue are applied tobond each separator to the ad-jacent pleat. This solidifies themedia pack to minimize move-ment and prevent media dam-age. Burst strength isincreased to prevent the filterfrom blowing out under vari-able air volume conditions orunusually high resistance.

    Galvanized steel headers andcell sides resist damage during

    shipping and handling, andprevent corrosion over longservice life. (HT VariCel filtersare constructed of aluminizedsteel.)

    Easy Installation

    Rigid construction and mini-mum depth make VariCel fil-ters easy to install in all typesof systems.

    VariCel

    Construction

    Header

    Cell Side

    Header

    Cell Side

    Potential Leak Path

    Typical

    Competitive

    Construction

  • 5/24/2018 CatalogAAF

    12/38

    10

    20

    30

    50

    40

    60

    70

    80

    100

    90

    .1 .2 .4 .6 .8 1 2 4 6 8 10

    0

    Efficiency by Particle Size*

    PARTICLE SIZE (MICRONS)

    EFFICIENCY(%)

    80-85%

    VARICEL/VARICEL with Intersept

    OPERATING DATA

    12" Deep Filters 6" Deep Filt ers

    FILTER FACE VELOCITY (FPM )

    INITIALRESISTANCE(IN.

    WG)

    Initial Resistance vs. Filter Face Velocity Operating Temperature Limits

    VariCel M odel Temperature Limit

    Types SH, DH, XL 350F 177C

    Type HT-500 500F 260C

    Type HT-725 750F 385C

    Type HT-900 900F 482C

    Type NH 200F 93C

    Underwr iters Labor atories Inc. Classification: All VariCels are Class1.

    Testing was performed according to U.L. Standard 900 and CAN 4-S111.

    OPTIONS

    VariCel f ilters can be ordered with faceguards

    made of flatt ened, expanded, aluminizedsteel on one or both sides of the filter.

    Factory installed gaskets are available on thefront or back of the header.

    Vinyl Coated Separators are available for cor-rosive conditions.

    1 18" Single Header Vari Cels, designed forother manufacturers' e quipment, are a lso

    available.

    90-95%

    90-95% XL/80-85%

    60-65%

    60-65% XL

    90-95%

    60-65%

    PREFILTERS CAN DOUBLE VARICEL LIFE

    Using prefilters, such as AAF's PerfectPleat pleated fil-ters or 5700 panel filters, will greatly extend the life ofVariCel filters.

    12" deep filters are rated at 500 FPM filter face velocity.6" deep filters are rated at 250 FPM filter face velocity.Recommended final resistance for all VariCel filters is 1.2" wg.

    * Tested in accordance with ASHRAE standards 52.2-199 9

    AFP-1-158P DEC '03 MP10M

    For Additional Information On AAF Products,Call Customer Service

    888.AAF.2003

    2003 AAF INTERNATIONAL

    10300 ORMSBY PARK PL STE 600LOUISVILLE KY 40223-6169P O BOX 35690LOUISVILLE KY 40232-5690

    www.aafintl.com

    90-95% (MERV 14)

    60-65% (MERV 11)

    80-85% (MERV 13)

  • 5/24/2018 CatalogAAF

    13/38

    VariCel II

    B E T T E R A I R I S O U R B U S I N E S S

    Low Depth Compact FilterFor Commercial and Industrial HVAC Systems

    Low depth saves space

    Classification ranges

    F6 and F8 Lightweight and

    easy-to-install

    Economic to transport

    High dust holdingcapacity

    When installation space is limited and highquality air filtration is required, VariCel IIis the solution. This low depth, lightweightfilter is available in EN779 classificationranges F6 and F8. It displays low mediaresistance which means low energyconsumption. Due to its lightweight andlow depth it is economic to ship comparedto other heavier, bulkier types of filter.

    VariCel II is suitable for use in front, rearand side access HVAC installations.The filter is also suitable for use in variableair volume systems and can withstandrepeated fan shut down and turbulentairflow. VariCel II has a high dust holdingcapacity and long service life. It can resistintermittent exposure to water andprovides excellent performance inconditions of high relative humidity.

    0 1.0 2.0 3.0 4.0

    0

    50

    75

    25

    100

    125

    175

    225

    200

    150

    60%

    90%

    2.5

    InitialResistance(Pa)

    Face Velocity (m/s)

    Initial Resistance vs Face Velocity

  • 5/24/2018 CatalogAAF

    14/38

    VariCel II

    RA-2-599-IN-1-0198 1998 AAF International

    Maximum operating temperature : 65 CMedia : Dual density glass fibreFilter frame : Natural kraft pine and hardwood fibreDisposal : Municipal incinerator

    Specification

    Underwriters Laboratories Inc. Listing

    VariCel II filters are Class 2 approved according to U.L. Standard 900.

    1) Width and height dimensions are interchangeable. VariCel II filters can be installed horizontally or vertically.2) All performance data based on ASHRAE 52: 1.1992. Classification in accordance with EN779.

    For maximum service life, VariCel II filters should always be operated with a prefilter.3) Available for side access installations designed with a 18 mm or 22 mm or customized wide stationary track.

    Technical Data

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice

    11.8010.319.858.188.838.186.505.852.97

    34002975280523802550238018701700

    850

    0.9440.8260.7800.6610.7080.6610.5190.4720.236

    0.9440.826

    0.7800.6610.7080.6610.5190.4720.236

    170170170170170170170170170

    100100

    100100100100100100100

    594x594x97492x619x97492x594x97492x492x97441x594x97391x619x97391x492x97289x594x97289x289x97

    24x24x43)

    20x25x420x24x43)

    20x20x418x24x416x25x416x20x412x24x43)

    12x12x4

    24x24x43)

    20x25x4

    20x24x43)20x20x418x24x416x25x416x20x412x24x43)

    12x12x4

    NominalSize1)

    (wxhxd)(inches)

    ActualSize1)

    (wxhxd)(mm)

    GrossMediaArea(m2)

    RatedAir FlowCapacity2)

    (m3/h) (m3/s)

    RatedInitial2)

    Resistance(Pa)

    90% Average Efficiency - F 8

    11.8010.31

    9.858.188.838.186.505.852.97

    34002975

    280523802550238018701700850

    594x594x97492x619x97

    492x594x97492x492x97441x594x97391x619x97391x492x97289x594x97289x289x97

    60% Average Efficiency - F 6

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    15/38

    VariPak

    B E T T E R A I R I S O U R B U S I N E S S

    Multi-Purpose High Efficiency Compact Filter

    For use as prefilter or finefilter

    F6, F7 and F8 classifiedaccording to EN779

    Various media pack depthsand cell side combinationsavailable

    Low resistance = longservice life

    Maximum operatingtemperature 70C

    Applications

    VariPak is a multi-purpose air filter.It can be used as aprefilterto aHEPA filter operating at low facevelocity or as a fine filterincommercial HVAC systems at arecommended face velocity of 1.0 -1.5 m/s. The filter is available in theclassification ranges F6, F7 and F8 in

    accordance with EN779.

    The Filter

    Depending on the application,VariPak can be supplied in a widevariety of mini-pleat media packdepths and cell side configurations,including non-shedding MDF,die-cut, extruded aluminium andaluminized U-profile. The ultra fineglass fibre media pack features

    thermoplastic separators whichmaintain uniform spacing betweenpleats and ensure low mediaresistance: low media resistancetranslates into low energyconsumption and long service life.The filter can be supplied with or

    without a one-piece gasket and incertain configurations with a

    faceguard.

    0 0.20

    150

    250

    200

    100

    50

    0.6 0.80.4 1.0 1.2 1.4 1.6 1.8 2.0

    VariPak 80%

    Face Velocity m/sec.

    InitialResistance

    Pa

    1

    2

    3

    4

    5

    00

    150

    250

    200

    100

    50

    1.00.5 1.5 2.0

    VariPak 90%

    Face Velocity m/sec.

    InitialResistancePa

    1

    2

    3

    45

    0 0.50

    60

    100

    80

    90

    40

    20

    50

    70

    30

    10

    1.0 1.5 2,0

    VariPak 60%

    Face Velocity m/sec.

    InitialResistance

    Pa

    5

    4

    3

    2

    1

    1: 25 mm 1.0 m/s 3: 48 mm 1.3 m/s 5: 96 mm 1.5 m/s

    2: 35 mm 1.0 m/s 4: 72 mm 1.5 m/s

    1: 25 mm 1.0 m/s 3: 48 mm 1.3 m/s 5: 96 mm 1.5 m/s2: 35 mm 1.0 m/s 4: 72 mm 1.5 m/s

    1: 25 mm 1.0 m/s 3: 48 mm 1.3 m/s 5: 96 mm 1.5 m/s2: 35 mm 1.0 m/s 4: 72 mm 1.5 m/s

  • 5/24/2018 CatalogAAF

    16/38

    VariPak

    RA-2-509-IN-1-0699 1999 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

    How to OrderBelow a typical example of the Style Code for a standard VariPak filter using theComponent Definition Code System.

    Item Component Component Code Definition

    A Filter Type VP = VariPak

    B Efficiency 6 = 60 - 65%

    9 = 80 - 85%

    10 = 90 -95%

    C Cell sides 10 = die - cut, 11 = Aluminium extrusion

    72 = MDF

    89 = Aluminized steel99 = Aluminium extrusion

    90 = Aluminium extrusion with 20 mm flange for 3 media

    D Pack Depth P = 25 mm R = 35 mm

    K = 48 mm M = 96 mm

    L = 72 mm

    E Bond 9 = Polyurethane

    2 = polyurethane flame retandant

    0 = none on filters with die-cut cell sides

    F Gasket type S = foamed polyurethane

    P = No gasket

    T = neoprene 6 mm

    A = specialG Gasket location 0 = none 2 = air leaving side

    1 = air entering side 3 = both sides

    H Faceguard P = none A = Aluminium

    E = epoxy coated steel U = Aluminized expanded metal

    Z = special

    I Faceguard location 0 = none 1 = Air leaving side

    2 = Air entry side 3 = Both sides

    Item A B C D E F G H I

    ComponentDefinition VP 6 72 K 9 S 2 P 0

    Standard Sizes and Ratings

    Size in mm Nominalwithout gasket airflow

    H W D m3/h m3/s

    96 mm pack

    610 610 292 2000 0,55

    610 610 149 2000 0,55

    72 mm pack

    610 610 292 2000 0,55610 610 149 2000 0,55

    48 mm pack

    610 610 78 1740 0,48610 610 149 1740 0,48

    35 mm pack

    610 610 78 1340 0,37

    610 610 56 1340 0,37

    25 mm pack

    610 610 78 1340 0,37610 610 56 1340 0,37

    x x

    x x

    x x

    x xx x

    x xx x

    x x

    x x

    x xx x

    Operating Temperature

    VariPak air filters have a maximumoperating temperature of 70C.

    Disposal

    MDF and die-cut versions can bedisposed of by incineration. Products

    with metal parts can be landfilled.

    Recommended Final Resistance

    The recommended final resistance is450 Pa.

  • 5/24/2018 CatalogAAF

    17/38

    VariCel V

    Lightweight andeasy to install

    Classification rangesF6, F7, F8 and F9

    Excellent performancein difficult operatingconditions

    High air volume capacity:upto 5000 m3/h

    High dust holding

    capacity

    VariCel V are lightweight compact filtersdesigned for use in industrial andcommercial HVAC installations.Available in the EN779 classification rangeF6 - F9, their rigid design and pleatedmedia pack with thermoplastic separatorsensure they deliver the desired air qualitywhen used in variable air volume systemsand subjected to repeated fan shutdown,

    high relative humidity and intermittentexposure to water.

    Due to their 5000m3/h capacity, VariCel Voffer many cost saving benefits. In newinstallations fewer filters are needed tohandle the same volume of air comparedto filters of the same size with a lowercapacity. Fewer filters mean less installationspace for the filtration system. They canalso be used in existing systems to increasethe air capacity. VariCel V display lowmedia resistance and have a high dust

    holding capacity and long service life.

    B E T T E R A I R I S O U R B U S I N E S S

    Lightweight Compact Filters For Commercial andIndustrial HVAC Systems

    Airflow ResistanceVV6-series 200

    175

    150

    125

    100

    75

    50

    25

    0

    95%

    80%60%

    0 1.0 2.0 3.0 4.0

    90%

    InitialResistance(Pa)

    Face Velocity (m/s)

  • 5/24/2018 CatalogAAF

    18/38

    Varicel V

    RA-2-08-IN-4-0198 1999 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    Specifications

    Maximum operating temperature : 70 CMedia : Ultra fine glass fibres woven into matSeparators : ThermoplasticCell Sides : Recycled polystyrene

    VV6- 6-24.24-124)

    VV6- 6-20.24-124)

    VV6- 6-12.24-124)

    VV6- 9-24.24-12

    VV6- 9-20.24-12

    VV6- 9-12.24-12

    VV6-10-24.24-12

    VV6-10-20.24-12

    VV6-10-12.24-12

    VV6-11-24.24-12

    VV6-11-20.24-12

    VV6-11-12.24-12

    592 x 592 x 292

    490 x 592 x 292287 x 592 x 292

    592 x 592 x 292

    490 x 592 x 292

    287 x 592 x 292

    592 x 592 x 292

    490 x 592 x 292

    287 x 592 x 292

    592 x 592 x 292

    490 x 592 x 292

    287 x 592 x 292

    5000

    41652500

    5000

    4165

    2500

    5000

    4165

    2500

    5000

    4165

    2500

    1,39

    1,150,69

    1,39

    1,15

    0,69

    1,39

    1,15

    0,69

    1,39

    1,15

    0,69

    4250

    35402125

    4250

    3540

    2125

    4250

    3540

    2125

    4250

    3540

    2125

    1,18

    0,980,59

    1,18

    0,98

    0,59

    1,18

    0,98

    0,59

    1,18

    0,98

    0,59

    60-65

    60-6560-65

    80-85

    80-85

    80-85

    90-95

    90-95

    90-95

    > 95

    > 95

    > 95

    6

    66

    7

    7

    7

    8

    8

    8

    9

    9

    9

    600

    600600

    600

    600

    600

    600

    600

    600

    600

    600

    600

    Type Size1)

    (mm)HxWxD

    Airflow

    Maximum Nominal

    m3/h m3/h m3/s

    AverageEfficiency2)

    %

    EN779

    Class2

    InitialResistanceat Nominal

    Airflow (Pa)

    FinalResistance3)

    (Pa)m3/s

    1) Width and height are interchangeable, pleats can be either vertical or horizontal without affecting performance.2) All performance data based on EN779.3) Recommended maximum value. Filters can be operated to a lower final resistance without materially effecting filter efficiency.4) Suffix "C" denotes cellulose media option.

    110

    110110

    125

    125

    125

    145

    145

    145

    180

    180

    180

    Technical Data

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    19/38

    BioCel I

    Airflow range:500 - 2000 m3/h

    Classified H11 inaccordance with EN1822

    Benefits in existing andnew installations

    Lower energy costs

    As a H11 EN1822 classified filter,BioCel I is the ideal choice for customerswishing to upgrade a non-HEPAinstallation to a HEPA installation. Withan airflow range of 500 - 2000 m3/h,BioCel I is ideally suited for variable airvolume and turbulent air flow systems.

    BioCel I displays low media resistance

    which results in lower energy costs andlonger service life. The filter is designedfor use in clean areas in the pharma-ceutical, microelectronic, semi-conductorand healthcare industries in which highefficiency air filtration on fine particulatesis required. Temperature limit: 90C.

    B E T T E R A I R I S O U R B U S I N E S S

    High Quality HEPA Filter For Use In Clean Zones

    Resistance vs Face Velocity

    0 1.871.51.13 2.250.37 0.750

    150

    250

    200

    100

    50

    149 mm 292 mm

    In

    itialResistance(Pa)

    Face Velocity (m/s)

  • 5/24/2018 CatalogAAF

    20/38

    BioCel I

    RA-2-527-IN-1-0897 1997 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    Size Classification Low Airflow Initial High Airflow Initial Efficiency* Media Area(mm) EN1822 m3/h Resistance (Pa) m3/h Resistance (Pa) % @ 0.3 m m2

    610 x 610 x 292 H11 2000 165 3000 250 98 14.6610 x 610 x 149 H11 1000 165 1500 250 98 6.8

    Technical Data

    Technical Data Standard Execution

    Dimensions : 610 x 610 x 292 mm, 610 x 610 x 149 mmMedia : Submicron glass fibres formed into high density paperCell sides : MDF

    Separators : Corrugated aluminiumBond : Cold cured resinGasket : One piece gasketDisposal : LandfillTemperature limit : 90 CStyle code : D72J9S2F

    Note: Non-standard sizes and executions available upon request

    * Efficiency % @ MPPS > 95%

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    21/38

    BioPak

    H11 classified inaccordance with EN1822

    Recessed pack ensureseasy handling

    Non-sheddingMDF cell sides

    Low resistance ensureslow energy consumption

    One-piece gasketprovides leaktight seal

    BioPak filters are classified H11 in

    accordance with EN1822. They are the

    ideal solution for upgrading an existing

    non-HEPA HVAC installation into a

    HEPA installation. Their recessed mini-

    pleat media pack make BioPak filters easy

    to handle and install while high quality

    MDF cell sides ensure a smooth non-

    shedding construction. The filter can be

    installed with the pleats in the vertical or

    horizontal position.

    BioPak filters offer low media resistance

    which results in low energy consumption

    and long service life. A one-piece gasket

    around the perimeter of the filter ensures

    leaktight installation. The filters are made

    of fully incinerable materials.

    Temperature limit: 70C.

    B E T T E R A I R I S O U R B U S I N E S S

    High Quality HEPA Filters

    Resistance vs Face Velocity

    0 0.300

    150

    250

    200

    100

    50

    149 mm

    292 mm

    0.45 0.60 0.75 0.90 1.05 1.20 1.37 1.50

    I

    nitialResistance(Pa)

    Face Velocity (m/s)

  • 5/24/2018 CatalogAAF

    22/38

    BioPak

    RA-2-539-IN-1-0897 1997 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    Size Classification Low Airflow Initial High Airflow Initial Efficiency* Media Area

    (mm) EN1822 m3/h Resistance (Pa) m3/h Resistance (Pa) % @ 0.3 m m2

    610 x 610 x 78 H11 600 90 1000 120 98 8.8610 x 610 x 149 H11 1000 120 1500 180 98 8.8610 x 610 x 292 H11 1000 90 2000 250 98 17.5

    Technical Data

    Technical Data Standard Execution

    Dimensions : 610 x 610 x 292 mm, 610 x 610 x 149 mm,610 x 610 x 78 mm

    Media : High density paper made from ultra-fine glass fibresCell sides : MDFSeparators : Thermoplastic ribbonBond : Cold cured resinGasket : One piece gasketDisposal : Incineration or landfillTemperature limit : 70 CStyle code : D72M9S2F for 292 mm depth

    D72K9S2F for 149 and 78 mm depth*

    Note: Non-standard sizes and executions available upon request

    * Efficiency % @ MPPS > 95%

    * Specify depths acquired

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    23/38

    BioCel V

    H10 classification inaccordance with EN1882

    High air capacity:3000 m3/h

    Reduced energy costsand long service life

    Lightweight andeasy to install

    BioCel V is designed for industrialHVAC installations in which HEPAquality air filtration is required. As a H10EN1882 classified air filter, BioCel V isideal for upgrading an existingnon-HEPA HVAC installation to aHEPA installation. The filters mini-pleatmedia provides high quality filtration onfine particulate matter removing tiny dust

    particles from the airstream efficiently.

    Because of its 3000 m3/h air capacity,BioCel V is an ideal choice in newinstallations as fewer filters are needed tohandle the same volume of air comparedto HEPA filters of the same size with alower capacity. Fewer filters means lessinstallation space. The filter displays lowmedia resistance which results in lowenergy costs and long service life.Lightweight, BioCel V is easy to handle

    and install. Temperature limit: 70C.

    B E T T E R A I R I S O U R B U S I N E S S

    High Quality Compact HEPA Filter for HVAC Systems

    Resistance vs Face Velocity

    0 1.871.51.13 2.250.37 0.750

    120

    200

    160

    80

    40

    20

    140

    180

    100

    60

    In

    itialResistance(Pa)

    Face Velocity (m/s)

  • 5/24/2018 CatalogAAF

    24/38

    BioCel V

    RA-2-541-IN-2-0899 1999 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    Size Classification Low Airflow Initial High Airflow Initial Efficiency* Media Area

    (mm) EN1822 m3

    /h Resistance (Pa) m3

    /h Resistance (Pa) % @0.3 m m2

    592 x 592 x 292 H10 2000 120 3000 200 95 20.4287 x 592 x 292 H10 1000 120 1500 250 95 9.0

    Technical Data

    Technical Data Standard Execution

    Dimensions : 610 x 610 x 292 mm, 292 x 610 x 292 mm,Media : Ultra-fine glass fibres formed into a high density paperCell sides : Polystyrene

    Separators : Thermoplastic ribbonDisposal : Landfill or incinerationTemperature limit : 70 CStyle code : BV6-2424-12 resp. BV6-1224-12

    Note: Non-standard sizes and executions available upon request

    * Efficiency % @ MPPS > 85%

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    25/38

    AstroCel I

    Filter class H13 and H14according to EN1822

    Non-sheddingconstruction

    Improves quality ofmanufacturing processesand products

    AstroCel I filters owe their excellent air

    cleaning efficiency to their advanced

    design. High quality MDF cell sides

    ensure a smooth, non-shedding

    construction, while a rigid pleated media

    pack with aluminium separators provides

    high efficiency air filtration on fine

    particulates at the lowest possible

    resistance. Galvanized steel and stainlesssteel cell sides are also available.

    AstroCel I filters are classified H13 and

    H14 in accordance with EN1822.

    Additional benefits include:

    Factory tested to meet the most

    stringent legal and industry

    requirements.

    Easy to install.

    B E T T E R A I R I S O U R B U S I N E S S

    High Efficiency Particulate Air Filter (HEPA)

    Resistance vs Face Velocity

    0 1.0 1.25 1.5 1.75 2.00.25 0.50 0.75 2.25

    0

    100

    50

    150

    400

    350

    300

    200

    250

    1234

    1. 292 mm, H13 3. 149 mm, H132. 292 mm, H14 4. 149 mm, H14

    InitialResistance(Pa)

    Face Velocity (m/s)

  • 5/24/2018 CatalogAAF

    26/38

    AstroCelI

    RA-4-701-IN-3-1299 1999 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    How to OrderBelow a typical example of how to order a standard AstroCel I filter usingthe Component Code Definition System.

    An AstroCel I can be ordered using the following Component Code Definition System.

    Use the table to specify a product suitable to your application requirements.

    Selection Table Standard Sizes and Ratings

    Item Component Component Code Definition*

    A Media A = Waterproof glass fibre

    E = Waterproof glass fibre

    B Cell Sides 24 = Galvanized steel

    26 = Stainless steel

    72 = MDF

    C Separators J = Aluminium

    D Bond 5 = Silicone

    9 = Cold cured resin

    E Gasket P = No gasket

    S = 7 mm, half round profile, one piece foamed

    T = 6 mm, flat profileY = 6,5 mm, silicone rubber

    F Gasket Location 0 = No gasket

    2 = One face

    3 = Both faces

    G Acceptance Level H = H13 99.95% @ MPPS, acc. to EN1822

    R = H14 99.995% @ MPPS, acc. to EN1822

    Size in mm Nominalwithout gasket1) airflow

    H W D m3/h m3/s

    610 305 149 500 0.14610 610 149 1000 0.28610 762 149 1250 0.35610 305 292 1000 0.28610 610 292 2000 0.56610 762 292 2500 0.69

    Item A B C D E F G

    ComponentDefinition A 72 J 9 S 2 H

    * Bold typeface: standard execution

    1) The H (Height) dimension also indicates

    the vertical position of the separators.

    AstroCel I filters should always beinstalled with the separators in the vertical

    position.

    2) Other sizes available on request.

    Notes:

    - Initial resistance at nominal airflow is:

    250 Pa for H13 filters

    320 Pa for H14 filters.

    - Recommended final resistance is 750 Pa.

    - Temperature limit: 90C.

    (200C for A 24 J 5 Y 2 R,

    260C for A 26 J 5 Y 2 R.)

    Efficiency

    Efficiency Efficiency EN1822

    @ 0.3 m @ MPPS

    99.997% H13 99.95%

    99.999% H14 99.995%

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    27/38

    AstroCel I HC

    High air volume filter:3000 m3/h

    Classified H12, H13 andH14 according toEN1822

    Space saving design

    Saves energy in existinginstallations

    AstroCel I High Capacity are classified

    H12, H13 and H14 in accordance with

    EN1822 and are designed for

    applications in which a high volume of

    air has to be throughput. Because of their

    high capacity, fewer filters are needed to

    handle the same volume of air compared

    to other HEPA filters of the same size.

    AstroCel I HC filters owe their high

    capacity to a unique separator design

    which allows denser packing of the filter

    media. The benefits to the customer are

    numerous:

    In new installations, fewer filters mean

    less costly installation space is

    necessary.

    In existing installations, low pressure

    drop means lower energy costs and

    longer service life.

    Standard individually tested.

    B E T T E R A I R I S O U R B U S I N E S S

    High Quality HEPA Filter

    Resistance vs Face Velocity

    0 1.0 1.25 1.5 1.75 2.00.25 0.50 0.75 2.25

    0

    100

    50

    150

    400

    350

    300

    200

    250

    1

    2

    1. 292 mm, H12 / H132. 292 mm, H14 Face Velocity (m/s)

    InitialResistance(Pa)

  • 5/24/2018 CatalogAAF

    28/38

    AstroCel I HC

    RA-4-721-IN-3-1299 1999 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    How to OrderBelow a typical example of how to order a standard AstroCel I HC filter using theComponent Code Definition System.

    An AstroCel I HC can be ordered using the following Component Code Definition System.Use the table to specify a product suitable to your application requirements.

    Selection Table Standard Sizes and Ratings

    Item Component Component Code Definition*

    A Media A = Waterproof glass fibre

    E = Waterproof glass fibre

    B Cell Sides 24 = Galvanized steel

    26 = Stainless steel

    72 = MDF

    C Separators H = Aluminium (HC pleat)

    D Bond 9 = Cold cured resin

    E Gasket P = No gasket

    S = 7 mm, half round profile, one piece foamed

    T = 6 mm, flat profile

    F Gasket Location 0 = No gasket2 = One face

    3 = Both faces

    G Acceptance Level G = H12 99.5% @ MPPS acc. to EN1822**

    H = H13 99.95% @ MPPS acc. to EN1822

    R = H14 99.995% @ MPPS acc. to EN1822

    Size in mm Nominalwithout gasket airflow

    H W D m3/h m3/s

    610 305 292 1500 0.42610 610 292 3000 0.83610 762 292 3750 1.04

    Item A B C D E F G

    ComponentDefinition A 72 H 9 S 2 H

    * Bold typeface: standard execution** Non leaktested filter

    1) The H (Height) dimension also indicates

    the vertical position of the separators.

    AstroCel I HC filters should always be

    installed with the separators in the vertical

    position.

    Notes:

    - Initial resistance at nominal airflow is:

    300 Pa for H12 / H13 filters

    350 Pa for H14 filters.

    - Recommended final resistance 750 Pa.

    - Temperature limit: 90C.

    (200C for A 24 H 5 Y 2 G),

    (260C for A 26 H 5 Y 2 G).

    Efficiency

    Efficiency Efficiency EN1822

    @ 0.3 m @ MPPS

    99.99% H12 99.5%

    99.997% H13 99.95%

    99.999% H14 99.995%

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    29/38

    AstroPak

    Non-sheddingconstruction

    Leakfree construction Filter class H13 and H14

    according to EN1822

    AstroPak filters owe their excellent air

    cleaning efficiency to their advanced

    design. High quality MDF cell sides

    ensure a smooth, non-shedding

    construction, while a rigid mini-pleat

    media pack with thermoplastic separators

    provides high efficiency particulate air

    filtration at the lowest possible resistance.

    AstroPak filters are classified H13 and

    H14 in accordance with EN1822.

    Additional benefits include: Fully incinerable. Recessed pack ensures easy handling. Installation with pleats in vertical or

    horizontal position.

    Also available with metal cell sides.

    B E T T E R A I R I S O U R B U S I N E S S

    High Efficiency Particulate Air Filter

    0 1.0 1.25 1.5 1.750.25 0.50 0.75

    0

    100

    50

    150

    400

    350

    300

    200

    250

    Face Velocity (m/s)

    Initial

    Resistance

    (Pa)

    2

    1

    1. 292 mm, H13

    2. 78 and 149 mm, H13

    Resistance vs Face Velocity

  • 5/24/2018 CatalogAAF

    30/38

    AstroPak

    RA-3-535-IN-3-1299 1999 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    How to OrderBelow a typical example of how to order a standard AstroPak filter usingthe Component Code Definition System.

    An AstroPak can be ordered using the following Component Code Definition System.Use the table to specify a product suitable to your application requirements.

    Selection Table Standard Sizes and Ratings

    Item Component Component Code Definition*

    A Media A = Waterproof glass fibre

    E = Waterproof glass fibre

    B Cell Sides 24 = Galvanized steel**

    72 = MDF

    C Media pack K = 2 deep - 48 mm.

    M = 4 deep - 96 mm

    D Bond 9 = Cold cured resin

    E Gasket P = No gasket

    S = 7 mm, half round profile, one piece foamed

    T = 6 mm, flat profile

    F Gasket Location 0 = No gasket

    2 = One face

    3 = Both faces

    G Acceptance Level H = H13 Min. 99.95% @ MPPS, acc. to EN1822

    R = H14 Min. 99.995% @ MPPS, acc. to EN1822

    1) AstroPak filters can be installed with theseparators in either the horizontal orvertical position.

    2) Always minimal 20 mm differencebetween packdepth and filterdepth.

    Notes:- Initial resistance at nominal airflow is:

    250 Pa for H13320 Pa for H14

    - Temperature limit: 70C- Final resistance 500 - 750 Pa

    Item A B C D E F G

    ComponentDefinition A 72 K 9 S 2 H

    * Bold typeface: standard execution** Cell sides with code number 24 is only available in a limited size range

    Size in mm Nominal Packwithout gasket1) airflow Depth

    H W D m3/h m3/s mm

    240 240 56 155 0.04 48610 305 56 500 0.14 48490 490 56 650 0.18 48610 610 56 1000 0.28 48305 305 78 250 0.07 48457 457 78 570 0.16 48305 610 78 500 0.14 48610 610 78 1000 0.28 48203 203 149 110 0.03 96305 305 149 250 0.07 96

    610 305 149 500 0.14 96457 457 149 570 0.16 96610 610 149 1000 0.28 96610 762 149 1250 0.35 96610 915 149 1500 0.42 96610 1220 149 2000 0.56 96610 1524 149 2500 0.69 96610 1830 149 3000 0.83 96762 762 149 1600 0.44 96762 915 149 1900 0.53 96762 1220 149 2500 0,69 96762 1524 149 3150 0.88 96762 1830 149 3800 1.06 96915 915 149 2250 0.63 96915 1220 149 3000 0.83 96915 1524 149 3800 1.06 96915 1830 149 4550 1.26 96305 305 292 500 0.14 96610 305 292 1000 0.28 96610 610 292 2000 0.56 96610 762 292 2500 0.69 96

    Efficiency

    Efficiency Efficiency EN1822

    @ 0.3 m @ MPPS

    99.997% H13 99.95%

    99.999% H14 99.995%

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.:+ 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    31/38

    AstroCel III 3400 MDF

    H12 and H13 inaccordance with EN1822

    3400 m3/h air volumesaves space

    Low energy consumption

    Non-sheddingconstruction

    AstroCel III is classified H12 or H13 in

    accordance with EN1822. The filter

    displays excellent efficiency on fine

    particulate matter and is designed for use

    in high air volume applications upto

    3400 m3/h. Due to its high capacity the

    filter has several benefits: in new

    installations, fewer filters are required to

    handle the same volume of air comparedto HEPA filters of the same size with a

    lower capacity. As a result, less

    installation space is required and

    installation time is significantly reduced.

    In existing installations, the filter's high

    media area ensures a low pressure drop

    which reduces energy costs. Other

    benefits include:

    high quality MDF cell sides ensure a

    smooth, non-shedding construction

    easy installation

    B E T T E R A I R I S O U R B U S I N E S S

    High Efficiency Particulate Air Filters

    Resistance vs Face Velocity

    0 0.50 3.002.00 2.501.501.00

    0

    100

    50

    150

    200

    300

    250

    In

    itialResistance(Pa)

    Face Velocity (m/s)

  • 5/24/2018 CatalogAAF

    32/38

    AstroCelIII 3400 MDF

    RA-4-139-IN-3-1299 1999 AAF International

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    An AstroCel III 3400 can be ordered using the following Component Code Definition System.Use the table to specify a product suitable to your application requirements.

    How to OrderBelow a typical example of how to order a standard AstroCel III 3400 filter usingthe Component Code Definition System.

    Selection Table Standard Sizes and Ratings

    Item Component Component Code Definition*

    A Type of Filter A39 = AstroCel III

    B Media A = Waterproof glass fibre

    C Cell Sides** 72 = MDF

    D Separators C = Thermoplastic

    E Bond 9 = Polyurethane cold cured resin

    F Gasket P = No gasket

    S = Polyurethane foam, half round profile, one piece

    G Gasket Location 0 = No gasket

    2 = One face

    H Acceptance Level G = H12 Min. 99.5% @ MPPS acc. to EN1822 **

    H = H13 Min. 99.5% @ MPPS acc. to EN1822I Faceguard Location 0 = No faceguard

    K Options Consult local sales office

    Item A B C D E F G H I K

    ComponentDefinition A39 A 72 C 9 S 2 G 0 -

    Sizein mm Nominalwithout gasket airflow

    H W D m3/h

    610 305 292 1500610 610 292 3400

    Notes:- Recommended final resistance 750 Pa.- Temperature limit 70C.- Initial resistance at nominal airflow: 250 Pa.

    * Bold typeface: standard execution** Non leaktested filter

    For 4000 and NG execution consult specification sheets RA-3-129 en RA-3-124.

    Efficiency

    Efficiency Efficiency EN1822@ 0.3 m @ MPPS

    99.97% H12 99.5%

    99.99% H13 99.95%

    AAF-International B.V.

    P.O.Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    33/38

    Non-Laminar Flow Cleanrooms

    Basic Design and Operating Considerations

    B E T T E R A I R I S O U R B U S I N E S S

    In a non-laminar cleanroom or, to use its

    official name, non-unidirectional airflow

    cleanroom, air enters the room via filters

    in the ceiling, and is exhausted via grilles

    in the wall close to the floor.

    The principle of this technique is based

    on allowing air to flow along irregular,

    random paths in a turbulent way.

    The success of this technique hinges on

    optimizing the mixing of clean incoming

    air with dust laden air in the room and

    thereby diluting the contamination level

    in the cleanroom and lowering the

    number of particles per m3. The supply

    of clean air is therefore the factor which

    determines the success of this technique.

    In general, the greater the frequency with

    which the air is renewed the lower the

    contamination build-up in the room andthe greater the rate with which

    impurities are diluted. On an hourly

    basis, the number of air changes in a

    room can vary between 10 and 50,

    depending on the type of work and the

    achievable Class of the room.

    Although more unpredictable than

    laminar airflow cleanrooms, in many

    applications a non-laminar flow room

    can be a cost effective solution, especiallywhen local laminar flow work stations

    are operational in the room.

  • 5/24/2018 CatalogAAF

    34/38

    Non-Laminar Flow Cleanrooms

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    CR-2-741-IN-0896 1996 AAF International

    Achievable Class* 1,000 (M4.5) 10,000 (M5.5) 100,000 (M6.5) Avoid

    Room size (m2) 100 300 500

    Room aspect ratio Narrow 3:1 2:1 Large square room

    Room height (m) min. 3 min. 2.75 min 2.25

    Area per occupant (m2) 20 10 5

    Equipment in room Minimum 30% Floor 50% Floor

    Occupant activity Sedentary Occasional movement Constant activity Frivolous activities

    Traffic in/out per hour 1-2 2-6 More than 6

    Occupants properly attired Full gowns Smocks Smocks Street clothes

    Particle generation in room Miniature Slight Considerable

    Thermal updrafts None Slight Considerable

    Housekeeping Meticulous Good Mediocre

    Room Pressure (Pa) 10-15 10-15 5-10 NoneAir changes per hour 40-120 20-40 10-20

    Airlock Adequate Small None

    Clean air inlets as % of ceiling area 20-50 10-20 5-10

    Clean air inlet locations Ceiling Ceiling Ceiling or high sidewall Floor

    Terminal velocity at clean air inlet (m/s) 0.15-0.45 0.15-0.45 0.15-0.45

    Return locations Low level or floor Low sidewall Sidewall Ceiling

    Wall return spacing Continuous on all Intermittent on long Non-uniform Single

    4 walls walls

    Max. horizontal distance to return (m) 3 6 9

    Return face velocity (m/s) 0.5-1 1-2.5 2.5

    Prefilters

    - First Stage** 50% dust spot eff. 90% arrestance 80% arrestance Doors open

    F5 G4 G4

    - Second Stage** 90% dust spot eff. 80-90% dust spot eff. 80-90% dust spot eff.

    F8 F7 F7

    Prefilter maintenance and inspection Quarterly Semi-annual Annual No schedule

    Final Filters** min.99.999% @ 0.3 m min. 99.99% @ 0.3 m min. 95% @ 0.3 m

    H14 H13 H10

    Routine particle count interval Monthly Monthly Quarterly

    Basic design and operating considerations

    * Class according to US Federal Standard 209E (between brackets in SI)** G and F classification in accordance with EN779. H classification in accordance with draft EN1822.

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Oslo (N),

    Lisbon (P), Johannesburg (RSA),Dalsjfors (S), Malm (S), Helsinki (SF)

  • 5/24/2018 CatalogAAF

    35/38

    Laminar Flow Cleanrooms

    The principle of laminar airflow or, to

    be more precise, unidirectional airflow

    cleanrooms is based on air moving along

    parallel streamlines at a uniform velocity

    of 0.3 to 0.45 m/s with as little

    turbulence as possible between the place

    where the air enters and exits the room.

    The principle is based on expelling any

    dust in the airflow by the shortest route.

    Basically, there are two types of laminar

    airflow cleanroom:

    a) Vertical downflow

    b) Horizontal crossflow

    Vertical Downflow

    In a vertical downflow cleanroom, air

    enters the room via filters in the ceiling

    surface and is exhausted via a perforated

    floor. This downward aiflow flushes

    contaminated air particles out of the

    room via the floor, thus preventing a

    build-up of contaminated particles.

    Particles generated at one work station

    are therefore removed before they have

    the chance to migrate. The air velocity

    in this type of cleanroom is usually 0.3

    to 0.45 m/s.

    Horizontal Crossflow

    In a horizontal crossflow cleanroom, the

    direction of airflow is from left to right

    or right to left across the room. Air

    enters the room via filters in one wall

    and is exhausted and/or recirculated via

    a bank of filters and perforated panels in

    the opposite wall. The air velocity has to

    be established at a sufficiently high level,

    usually 0.45 m/s, to counter the effects

    of upward thermal movement of

    particles. In work stations close to the

    high efficiency filter wall, Class 100 or

    better is possible.

    Since the flow of particles in this type of

    cleanroom is in the horizontal direction,

    the particle contamination generated atone work station can be transported to

    work stations further downstream of the

    filters. This, however, is dependent on

    the type of work or the process(es) being

    carried out in the cleanroom. Horizontal

    crossflow is nevertheless a very practical

    and cost effective system, particularly in

    cleanrooms which have to be built in

    existing spaces with limited ceiling

    height.

    B E T T E R A I R I S O U R B U S I N E S S

    Basic Design and Operating Considerations

  • 5/24/2018 CatalogAAF

    36/38

    Laminar Flow Cleanrooms

    CR-2-740-IN-0896 1996 AAF International

    AAF-International B.V.

    P.O. Box 7928

    1008 AC Amsterdam

    The Netherlands

    Tel.: + 31 20 549 44 11

    Fax: + 31 20 644 43 98

    International AAF Offices:

    Vienna (A), Montreal (CDN), Dortmund (D),

    Vitoria (E), Paris (F), Cramlington (GB),

    Athens (GR), Milan (I), Riyadh (KSA),

    Mexico (Mex), Amsterdam (NL), Singapore,

    Istanbul (TR), Louisville, Ky (USA)

    AAF Agents:

    Copenhagen (DK), Bangalore (IND)

    Oslo (N), Lisbon (P), Johannesburg (RSA),

    Dalsjfors (S), Malm (S), Helsinki (SF)

    AAF has a policy of continuous product research and improvement and reserves the right to change design andspecifications without notice.

    Achievable Class* 1 and 10 (M1.5 and M2.5) 100 (M3.5)

    Area per occupant 40 m2 30 m2

    Occupants properly attired Full gowns Full gowns

    Occupant activity Minimum Minimum

    Equipment in room Minimum Minimum

    Housekeeping Meticulous Meticulous

    Room pressurized 15 Pa 15 Pa

    Air changes per hour 500-600 500

    Air lock Yes Yes

    Clean air inlets as % of ceiling area 90-100% 90%

    Clean air inlet locations Ceiling Ceiling (wall)

    Terminal velocity at clean air inlet 0.3 - 0.45 m/s 0.3 - 0.45 m/s

    Return air location Perforated floor Low level or floor(opposite wall, 0.45 m/s)

    Prefilters:

    - First stage** 30% dust spot efficiency 50% dust spot efficiency

    F5 F5

    - Second stage** 95% @ 0.3 m 90% dust spot efficiency

    H10 F9

    Prefilter maintenance and inspection Monthly Monthly

    Final filters** Min. 99.9995% on 0.12 m (for Class 10) Min. 99.999% @ 0.3 um

    U15 H14

    Min. 99.99995% on 0.12 m (for Class 1)

    U16

    Routine particle count interval Daily Weekly

    * Class according to US Federal Standard 209E (between brackets in SI)** G and F classification in accordance with EN779. H and U classification in accordance with draft EN1822.

    Basic design and operating considerations

  • 5/24/2018 CatalogAAF

    37/38

    EN779

    B E T T E R A I R I S O U R B U S I N E S S

    New European Standard for Coarse and Fine Filters

    In 1993, the European Committeefor Standardization, TechnicalCommittee 195, Work Group 1

    (CEN/TC195-WG1) established anew standard for general ventilationfilters. With the introduction of thisstandard under document name EN779, member countries of theEuropean Union are obliged to issuetheir own national version of thisstandard within the existingframework of their own nationalstandards organizations.For example, BS EN 779 in the U.K.

    and DIN EN 779 in Germany.EN 779 is based on existingdocuments such as EUROVENT

    4/5, and ASHRAE 52.1:1992, but isin fact more stringent than either ofthese standards. The standardincorporates a new system ofclassification for Coarse and Finefilters based on an average dust spotefficiency at a specified final pressuredrop.

    Filters with an initial dust spotefficiency below 20% are classified as

    Arrestance Filters (Coarse Filters) inthe range G1 - G4. Final pressuredrop for certification is specified at

    250 Pa maximum. Filters with aninitial dust spot efficiency above 20%are classified as Efficiency Filters(Fine Filters) in the range F5 - F9.The final pressure drop forcertification is set at 450 Pamaximum.

    The table summarizes theclassification of the EN 779 forgeneral ventilation filters.

    Filter

    Classification

    G1G2G3G4F5F6F7

    F8F9

    Initial Dust SpotEfficiency Eo

    Average Arrestance

    Am (%)

    Am < 6565 Am < 8080 Am < 90

    90 Am---

    --

    Eo < 20%

    Average Efficiency

    Em (%)

    ----

    40 Em < 6060 Em < 8080 Em < 90

    90 Em < 9595 Em

    Eo 20%

    Note:For your information, the CEN/TC 195 Work Group 1 will continue to upgrade its standardization for general ventilation filters.To this end, EUROVENT has produced a particle count method under document name EUROVENT 4/9 which will form thebasis for a future new standard. WG 1 has also expressed its intention to work in closer liaison with ASHRAE on this subject.

    CR-3-1167-IN-0896

    AAF-International B.V., P.O. Box 7928, 1008 AC Amsterdam,The NetherlandsTel.: + 31 20 549 44 11, Fax: + 31 20 644 43 98

  • 5/24/2018 CatalogAAF

    38/38

    On a flat sheet of media, the MPPS is determinedfor the given media velocity. This can be done

    with a laser spectrometer or a combination ofelectrostatic classifier and CNC (CondensedNucleus Counter).

    The filter is assembled with the specified mediagrade and amount of media to comply with thedefined media velocity.

    The filter is challenged with an aerosol and at theMPPS both the local and overall efficiency isdetermined with either a CNC or laserspectrometer.

    Leaks are specified as maximum allowable localpenetration at the MPPS and must not exceed5 x the overall penetration.

    The filter is classified according to the test resultsin the range H10 - H14 for HEPA,U15 - U17 for ULPA.

    Penetration vs Particle Size

    Particle Size (microns)

    Penetration(%)

    Face Velocity 5.00 cm/s(Resistance = 36.36 mm)

    (MPPS = 0.134 m)

    MinimumEfficiency

    Face Velocity 3.50 cm/s(Resistance = 26.05 mm)

    (MPPS = 0.146 m)

    Face Velocity 2.50 cm/s(Resistance = 18.70 mm)

    (MPPS = 0.159 m)

    Face Velocity 1.70 cm/s(Resistance = 9.65 mm)

    (MPPS = 0.172 m)

    Face Velocity 1.30 cm/s(Resistance = 9.65 mm)

    (MPPS = 0.189 m)

    Face Velocity 0.90 cm/s(Resistance = 6.75 mm)

    (MPPS = 0.212 m)

    Filter

    Classification

    H 10

    H 11H 12H 13H 14

    U 15U 16U 17

    Overall Value

    = > 85

    = > 95= > 99.5= > 99.95= > 99.995

    = > 99.9995= > 99.99995= > 99.999995

    Local Value

    -

    --99.7599.975

    99.997599.9997599.9999

    Overall Penetration

    15

    50.50.050.005

    0.00050.000050.000005

    Local Penetration

    -

    --0.250.025

    0.00250.000250.0001

    Efficiency (%) at the MPPS Penetration (%) at the MPPS

    Notes:

    Filters in the class H10, H11 and H12 do not require verification of local penetration. Filters in the classification H13 and H14 may, as an alternative, be verified with the visual oil-smoke test (previously known as DIN 24.184),

    which is accepted as equal or more searching than the specified local penetration. U17 is an exception to the rule. In this case local penetration may not exceed 20 x the overall penetration value.

    CR-2-489-IN-1-0398

    B E T T E R A I R I S O U R B U S I N E S S

    AAF-International B.V., P.O. Box 7928, 1008 AC Amsterdam, The NetherlandsTel.: + 31 20 549 44 11, Fax: + 31 20 644 43 98

    1998 AAF International

    EN1822

    New European Standard for HEPA & ULPA Filters

    Procedure