catalog A9

download catalog A9

of 19

Transcript of catalog A9

  • 8/10/2019 catalog A9

    1/19

    XK3190-A9

    WEIGHING INDICATOR

    MANUAL

    PLEASE READ THI S MANUAL VERY CAREFULLYBEFORE USE

    Dec 2006

    Specifications subject to change without prior notice

  • 8/10/2019 catalog A9

    2/19

  • 8/10/2019 catalog A9

    3/19

    2

    Wei ghi ng dat a save pr ot ect i on i n case of power of f

    I ndi cat i ng f or bat t er y vol ume or st at us

    Pr ot ect i on f or l ow bat t er y

    AC/ DC power suppl y, wi t h out si de r echargeabl e 12V/ 7AH

    bat t er y

    Standard RS232 communi cat i on i nt er f ace wi t h sel ectabl e

    baud r at e and communi cat i on met hod

    Standard scor eboar d i nt erf ace wi t h 20mA curr ent l oopp

    St andar d par al l el pr i nt i nt er f ace, abl e t o connect wi t h

    9- pi n or 24- pi n wi de- l i ne pr i nt er

    2.TECHNICAL PARAMETERS AND SPECIFICATIONS

    Model : XK3190- A9

    Accur acy: Cl ass I I I , N=3000 A/ D Conver si on Method: Doubl e i ntegr al

    I nput Si gnal Range: 0mV ~ 18mV

    Max. net i nput si gnal r ange: 18mV

    A/ D conversi on speed: 10~15 t i mes/ sec.

    Nonl i near i t y: 0. 01%FS

    Load Cel l Exci t at i on: DC8V; I250mA

    Max. connect i on number of l oad cel l : 8 at 350 ohm or 16

    at 700 ohm

    Load cel l connect i on mode: 6 wi r e, aut o compensat i on f or

    l ong di st ance50 met er s

    Di spl ay: 7 bi t s LED, 7 st at us i ndi cat i ons, 3 bat t er y

    i ndi cat i ons

    Di vi si on: 1/ 2/ 5/ 10/ 20/ 50/ 100 opt i onal

    Cl ock: r eal cl ock wi t hout ef f ect on power of f

    Scor eboar d i nt er f ace ( St andar d)

    Ser i al sendi ng si gnal by cur r ent l oop wi t h baud r at e 600.

    Tr ansmi ssi on di st ance: Cur r ent l oop100 met ers;

    Communi cat i on i nter f ace( RS232 C st andar d; RS422

    opt i onal )

    Ser i al communi cat i on i nt er f ace, wi t h sel ect abl e baud rat e by

    cont i nuous sendi ng met hod or on command met hod

    Tr ansmi ssi on di st ance: RS232C30 met ers; RS4221200 met er s

    Pr i nt i nt er f ace ( St andar d)

    Par al l el sendi ng, abl e to connect wi t h wi de- l i ne pr i nt er model

    TM800KX- P1121KX- P1131LQ300KLQ1600K;

    Power suppl y: AC 187~242V, 49~51HZ; DC out si de

    r echargeabl e 12V/ 7AH bat t ery; bat t ery charge t i me about 30

    hours and 16 hours usage t i me af t er char ge t hen charge agai n

    Fuse f or AC: 500mA; f use f or DC: 1. 5A

  • 8/10/2019 catalog A9

    4/19

    3

    2

    5

    8

    3

    6

    9

    0

    1

    4

    7

    XK3190-A9kg

    TrackNo.

    TimeCode Auto Dat e Stabl e Tare Zero

    Battery

    PresetTare

    StoreTare

    Tare Input

    Art.No.

    Time Da te F un c. We igh

    Print

    Set

    Accum.

    Print

    Add.

    Print

    Print Zero

    AC Socket

    PrinterCommunication

    & Scoreboard

    Loadcell

    DC Fuse

    AC Fuse

    Power

    DC Start Button

    DC Socket

    3. LAYOUT AT FRONT AND BACK

    3. 1 Front view of the indicator

    3. 2 Back view of the indicator

    4. Connecting to Other Devices 1through various

    interfaces

    4.1 Connection to load cell

    Connect t hi si ndi cat or t o l oad cel l t hr ough t he 9- pi n l oad cel l

    connect or l ocat ed at t he back. Ref er t o the bel ow t abl e f or

    l oad cel l pi n assi gnment .

    Short connect PIN 1 AND PIN 2, PIN 6 and PIN 7 when connected

    to load cell with a 4-wire cable;

    CAUTION

    Connection between load cell and indicator must be reliable;

    shield-wire must be connected to ground reliably;

    Load cell and indicator are all

    1 Turn scale off and cut off power before making any connections or disconnections.

    PIN # ASSIGNMENT

    1 E-

    2 S-

    5 SHI ELD

    6 E+

    7 S+

    8 I N-

    9 I N+

  • 8/10/2019 catalog A9

    5/19

    4

    static-electricity-sensitive devices, measures must be taken

    to ensure safety.

    4.2 Connection to PC or SCOREBOARD

    From t he 15- pi n i nt er f ace l ocat ed at t he back, you coul d

    Connect i ndi cator t o computer vi a RS232 out put or

    RS422 out put ( opt i onal ) ;

    Connect i ndi ct or t o scor eboar d vi a 20mA curr ent

    l oop out put ;

    15- pi n connector

    4. 2. 1 Connect t o PC

    Data f ormat f or RS232 or RS422 i s t he same. Data i s t r ansmi t t ed

    i n ASCI I code. Dat a f or mat i s as l i st ed bel ow( one gr oup) :

    1 2 3 4 5 6 7 8 9 10

    START DATA STOP

    Ther e ar e t wo modes t o communi cat e wi t h PC:

    Cont i nuousl y send, and

    Command mode.

    A. Continuously send

    Dat a t r ansmi t t ed i s t ar e wei ght or net wei ght f r omt he di spl ay

    of t he i ndi cat or. Each t i me i t sends one f r ame dat a t o pc, one

    f r ame consi st s of 12 gr oups whi l e the data f ormat of one gr oup

    i s as l i st ed above. Bel ow i s t he cont ent f or one f r ame:

    PIN # ASSIGNMENT PIN # ASSIGNMENT

    1 RS422 OUTPUT+ 9 SCOREBOARD OUT+

    2 RS422 OUTPUT- 10 SCOREBOARD OUT-

    3 RS422 I N+

    4 RS422 I N-

    6 RS232 RXD

    7 RS232 TXD

    8 GND

    Not e1: RS422 out put i s opt i onal ;

  • 8/10/2019 catalog A9

    6/19

    5

    For example,

    Now the indicator displays 50.00KG, then the frame indicator

    sends to PC is : +0050002;

    If the indicator displays -0.040KG, then the frame indicator

    sends to PC is : -0000403;

    B. Command mode

    I ndi cat or wi l l act accor di ng t o i nst r ucti on f r om PC, one

    i nstr uct i on f romPC wi l l t r i gger one act f r om i ndi cat or.

    For mat of i nst r ucti on f r om PC i s as f ol l owed:

    For mat of dat a f r om i ndi cat or i s as f ol l owed:

    GROUP

    NO.

    CONTENT NOTES

    1 02( XON) START

    2 OR SI GN SI NAL

    3 Hi gh di gi t

    4

    5

    6

    7

    8

    WEI GHI NG

    DATA

    Low di gi t

    9Deci mal

    poi nt

    Fr omr i ght t o l ef t , deci mal poi nt i s f r om0~4

    ; 0 f or no deci mal poi nt , 1 f or 1 deci mal poi nt ;

    10 Ver i f y XOR HI GHT 4 BI TS

    11 Ver i f y XOR LOW 4 BI TS

    12 03( X0FF) STOP

    XOR=2389

    GROUP NO. CONTENT NOTE

    1 02( XON) START

    2 ADDRESS Fr om A~Z

    A: For SHARKE

    B: For GROSS W

    C: For TARE W

    3 COMMAND

    ( FROM A~D)

    D: For NET W

    4 XOR HI GHT 4 BI TS

    5

    Ver i f y

    XOR LOW 4 BI TS

    6 03(XOFF) STOP

    NOTE: XOR=23

  • 8/10/2019 catalog A9

    7/19

    6

    Cont ent of 4~N i s as f ol l owed t abl e accor di ng t o di f f er ent

    command:

    Not e: For ver i f y of XOR

    Hi gh 4 bi t s and l ow 4 bi t s of XOR i s def i ned: i f hi gh 4 bi t s

    or l ow 4 bi t s of XOR i s 9, t hen add 30h and t r ansmi t i n ASCI I

    code; i f hi gh 4 bi t s or l ow 4 bi t s of XOR i s >9, hen add 37h

    and t r ansmi t i n ASCI I code

    C. Parameter setting at indicator for communication with PC

    There are mainly three parameters to be set for communication

    with PC, they are address, baud rate and communication method.

    To set these parameter, first connect indicator to load cell

    properly so that indicator will work properly. Open the

    calibration board at the back of indicator, you will see the

    GROUP NO. NOTES

    1 START XON ( 02)

    2 ADDRESSA~Z

    A: TO SHARKE

    B: To send GROSS W

    C: To send TARE W

    3

    A~D

    D: To send NET W

    4

    N- 1

    N

    COORESPONDI NG DATA ACCORDI NG TO COMMAND

    N+1 Ver i f y HI GH 4 BI TS OF XOR

    N+2 Ver i f y LOW 4 BI TS OF XOR

    N+3 03( XOFF) STOP

    XOR=23( n- 1 )n

    COMMAND A NO DATA ONE FRAME ( 6 GROUPS)

    A: Si gn bi t ( +/ - )

    B: Hi ghest bi t ( 6 BI TS)

    ( f r om hi gh t o l ow)

    G:

    COMMAND B

    : TO SEND

    GROSS

    WEI GHT

    H: DECI MAL POI NT( 0~4)

    ONE FRAME ( 14 GROUPS)

    A: Si gn bi t ( +/ - )

    B: Hi ghest bi t ( 6 BI TS)

    ( f r om hi gh t o l ow)

    G:

    COMMAND C

    : TO SEND

    TARE WEI GHT

    H: DECI MAL POI NT( 0~4)

    ONE FRAME ( 14 GROUPS)

    A: Si gn bi t ( +/ - )

    B: Hi ghest bi t f or g. w

    ( f r om hi gh t o l ow)

    G:

    COMMAND D

    : TO SEND

    NET WEI GHT

    H: DECI MAL POI NT( 0~4)

    ONE FRAME ( 14 GROUPS)

  • 8/10/2019 catalog A9

    8/19

    7

    calibration switch, turn the switch to right, then you could

    set these parameter as followed table:

    4. 2. 2 Connect t o Scoreboar d

    Dat a i s t r ansmi t t ed ser i al l y i n bi nar y code wi t h baud r at e 600.

    Dat a f or mat i s as l i st ed bel ow ( one gr oup) :

    I ndi cat or sends one f r ame data to scoreboar d per 100ms, one

    f r ame consi st s of 3 gr oups whi l e t he dat a f ormat of one group

    i s as l i st ed above. Bel ow i s t he cont ent f or one f r ame:

    0 1 2 3 4 5 6 7 8 9 10

    D0 D1 D2 D3 D4 D5 D6 D7 SI GN STOPGr oup

    1 StartX Y G18 G16 G17 0 1

    0 1 2 3 4 5 6 7 8 9 10

    D0 D1 D2 D3 D4 D5 D6 D7 SI GN STOPGr oup

    2 StartG8 G9 G10 G11 G12 G13 G14 G15 0 1

    0 1 2 3 4 5 6 7 8 9 10

    D0 D1 D2 D3 D4 D5 D6 D7 SI GN STOP

    Gr oup

    3 StartG0 G1 G2 G3 G4 G5 G6 G7 1 1

    For group one, Si gn bi t i s 0; X( D0, D1, D2) means deci mal poi nt( 0~4) ; YD3means si gn( 1 f or negat i ve whi l e 0 f or posi t i ve) ;

    Y ( D4) f or back up; G18, G17 and G16 i s bi nary code;

    For gr oup two, Si gn bi t i s 0; G15~G8 i s bi nar y code;

    For gr oup t hr ee, Si gn bi t i s 1; G7~G0 i s bi nary code;

    FromG0~G18 consi st s of 18 bi t bi nary code, l ow pr i or t o hi gh,

    wi t h cont ent of wei ghi ng dat a

    Step Operation Display Explanation

    1 Press

    [function]

    2 Press[input] [E **] Non-communication parameter

    setting, not change it. Press

    [input] to next step.

    3 Press[input] [dc *] Non-communication parameter

    setting, not change it. Press

    [input] to next step.

    4 Press[input] [Pn *****] Non-communication parameter

    setting, not change it. Press

    [input] to next step.

    5 Press[input] [F *****] Non-communication parameter

    setting, not change it. Press

    [input] to next step.

    6 Press[1]

    Press[input]

    [Adr **]

    [Adr 01]

    Communication address(01-26)

    Example:1

    7 Press[1]

    Press[input]

    [bt *]

    [bt *]

    Baud rate(0-4), indicate the

    baud rate respectively.

    600,1200,2400,4800,9600

    Example:1

    8 Press[0]

    Press[input]

    [tF *]

    [tF *]

    Communication method(0~1)

    0-Continously sending

    1-On command

    Example: 0

    9 Weigh

    status

    Finish

    0 1 2 3 4 5 6 7 8 9 10

    START DATA( Low i s pr i or t o hi gh) SI GN STOP

  • 8/10/2019 catalog A9

    9/19

    8

    4.3 Connection to Printer

    25- pi n i nt er f ace

    Descri pt i on f or each pi n i s as l i st ed i n above t abl e. Bef or e

    pr i nt oper at i on, f i r st set up par amet er f or pr i nt f uncti on,

    t hen connect i ndi cat or t o pr i nt er wi t h pr i nt er cabl e. Pl ease

    r ef er t o f ol l owed t abl e f or par amet er set t i ng:

    St ep Operat i on Di spl ay Note

    1 Pr ess [ pr i nt

    set]

    Press [9] [7]

    Pr ess [I nput ]

    [ P 00]

    [ P 97]

    I nput Password 97

    2 Pr ess [ 1]

    Pr ess [I nput ]

    [ Aut o *]

    [ Aut o 1]

    Sel ect Aut o/ Manual Pri nt

    0- Manual

    1- Auto

    3 Pr ess [ 3]

    Pr ess [I nput ]

    [ Type *]

    [ Type 3]

    Sel ect pr i nt er t ype:

    0- Pr i nt i nval i d

    1- TPup16( mi cr o- pr i nt er ]

    2- TM800 pri nt er

    3- Panasoni c KX- P1121

    4- Epson LQ- 1600K

    5- Bui l t i n pr i nt er ( For

    A9P)

    4 Pr ess [ 5] [ 0]

    Pr ess [I nput ]

    [ HL **]

    [ HL 50]

    Pr i nt onl y when:

    00- Back t o zer o

    25- Back t o

  • 8/10/2019 catalog A9

    10/19

    9

    6 Pr ess [ 1] [ 0]

    [0]

    Pr ess [I nput ]

    [L *****]

    [ L001. 00]

    Set mi n. wei ght f or aut o

    pr i nt f uncti on

    I t must be l ager t han 10d

    f or exampl e: 1. 00

    7 Pr ess [ 0] [ 5]

    Pr ess [I nput ]

    [b **]

    [ b 05]

    Rows f or pr i nt er ( 0~30)

    8 Press [ 1]

    Pr ess [I nput ]

    [ Ode *]

    [ Ode *]

    Sel ect f i l l ed- i n pr i nt :

    0- Not sel ect

    1- Sel ect

    9 Press [ 1]

    Pr ess [I nput ]

    [ Dct *]

    [ Dct 1]

    Sel ect di scount r at e at

    f i l l ed- i n pr i nt f orm:

    0- Not use di scount r at e

    1- Use di scount r at e

    10 Press [ 0] [ 1]

    [1]

    Pr ess [I nput ]

    [Y *****]

    [ Y 00011]

    Non zer o i nput wi l l be

    r egarded as 12

    11 Press [ 8] [ t el n *] Sel ect t el ephone number

    2 For parameter Y, there are 5 bits, from left to right, it corresponds 1~5, definition for

    each bit is as followed:

    Bit 1 for weighing mode: 0 Two times weighing mode; 1 one time weighing mode

    Bit 2 for power save choice: 0 not choose; 1 choose

    Bit 3 for weight unit: 0 KG; 1 Ton

    Bit 4 for choice for cargo no.: 0 not use; 1 use

    Bit 5 for choice for truck no.: 0 not use; 1 use

    Pr ess [ I nput ] [ t el n 8] bi t s( 0~8)

    0- No t el ephone number

    The ot her - t el ephone

    number

    12 Press

    [5][8][8][6]

    Pr ess [I nput ]

    [ t H ****]

    [ t H 5886]

    Set f or hi gh 4 bi t s of

    t el ephone number

    13 Press

    [0][0][0][3]

    Pr ess [I nput ]

    [ t l *** *]

    [ t l 0003]

    Set f or l ow 4 bi t s of

    t el ephone number

    Not e 1: For A9 model , pr i nt er t ype coul d onl y be t ype 1, 2, 3, 4;

    Not e 2: St ep 8, 9 i s onl y val i d when pr i nt er t ype i s 2, 3;

    Not e 3: St ep 11, 12, 13 i s onl y val i d when pr i nt er t ype i s 5;

    Not e 4: Onl y when t he pr i nt f or mat i s f i l l ed- i n, di scount r at e

    i s r at ed;

    Not e 5, For pr i nt f or mat exampl e, pl ease ref er t o appendi x;

    Not e 6, I f pr i nt par amet er set i s val i d, pr ess [ pr i nt ] coul d bot h

    t r i gger save and pr i nt oper at i on, t hat i s t o say, save one

    wei ghi ng r ecor d whi l e pr i nt ;

    Not e 7, I f a wei ghi ng r ecor d i sn t pr i nt ed out due t o pr obl em

    of pr i nt er or ot her , pr ess [ Add pr i nt ] coul d pr i nt out t he l ast

    saved wei ghi ng r ecor d af t er pr obl em i s sol ved.

    Not e 8, Pri nt [ Accu pr i nt ] , t hen accumul at i on f or wei ghi ng

  • 8/10/2019 catalog A9

    11/19

    10

    r ecor ds wi t hi n a per i od coul d be pr i nt ed out ;

    Not e 9, Pr ess [Pri nt set ] , and [ 0] [ 1] , i ndi cat or coul d pr i nt out

    wei ghi ng r ecor ds gr oup by date, t r uck no. and cargo no.

    Not e 10, I f i ndi cat or i s set as t wo t i mes wei ghi ng mode, no matt er

    f i r st l oaded, t hen unl oaded or f i r st unl oaded t hen l oaded, f or

    t he f i r st t i me save, i ndi cat or j ust di spl ay [ LoAd] f or 1. 5

    seconds to i ndi cator operator due t o uncompl ete wei ghi ng

    dat a, but not pr i nt . But pr ess [ Add pr i nt ] coul d pr i nt out t he

    uncompl ete wei ghi ng r ecor d as f ol l owed:

    1, Ser i al no. : bl ank;

    2, Gr oss W, net W: 0

    3, Tar e W: Cur r ent di spl ay

    Not e 11, I f i ndi cat or i s set as one t i me wei ghi ng mode, i ndi cat orwi l l bot h save and pr i nt f or ever y ti me wei ghi ng. I f i ndi cat or

    i s at t ar e st at us, t hen cur r ent t ar e wei ght wi l l be r egar ded as

    saved t ar e wei ght ; i f i ndi cat or i sn t at t ar e st at us, t hen

    i ndi cat or wi l l r ecal l saved t ar e wei ght accor di ng t o t r uck

    no. ( I f t her e i s no saved i nf o, t hen t ar e wei ght wi l l be r egar ded

    as 0)

    5. Calibration

    Fi r st connect i ndi cat or t o l oad cel l pr oper l y so t hat i ndi cat or

    wi l l wor k pr oper l y. Then open the cal i br at i on boar d at t he back

    of i ndi cat or , you wi l l see t he cal i br at i on swi t ch, t ur n t he

    swi t ch t o r i ght , t hen you coul d cal i br at e as f ol l owed t abl e:

    step Operation Display Note

    1 pr ess [ FUNC]

    2

    pr ess [ 1 ] [ 0 ]

    pr ess [ I nput ]

    [ E ** ]

    [ E 10 ]

    Ent er di vi si on:

    1/ 2/ 5/ 10/ 20/ 50/ 100

    Exampl e: 10

    3

    pr ess [ 0 ]

    pr ess [ I nput ]

    [ dc * ]

    [ dc 0 ]

    Ent er deci mal poi nt ( 0 - 4)

    Exampl e: wi t hout Deci mal poi nt

    0

    4

    press [ 1 ] [ 2 ]

    [ 3 ]

    pr ess [ I nput ]

    [ pon

    VWXYZ ]

    [ pon

    00123 ]

    Ent er Par ameters val ue: 3

    V: Appl i cat i on ( 0- 1)

    0: Non Commer ci al

    1: Commerci al

    W: Zero t r ack speed( 0~3)

    X: Zero t r ack range ( 0~9)

    Y: Manual zer o r ange( 1~5)

    Z: Auto zer o r ange( 1~5)

    3

  • 8/10/2019 catalog A9

    12/19

    11

    5

    pr ess [ 3 ] [ 0 ]

    [ 0 ] [ 0 ] [ 0 ]

    [ F

    ***** ]

    [ F

    30000 ]

    I nput F. S.

    I f need cal i br at i on, ent er F

    val ue, t hen pr ess [ I nput ] .

    Di r ectl y t o st ep 10 i f pr ess

    [ I nput ] , back t o wei ghi ng

    st at us i f pr ess[ wei gh ]

    6 press [ I nput ] Exampl e: 30000

    7 pr ess [ I nput ] [ noLoad

    n]

    Zer o poi nt cal i br at i on, pr ess

    [ i nput ] when t he st abl e l i ght i s

    on and assure i t s unl oaded

    8 pr ess [ 2 ] [ 0 ]

    [ 0 ] [0 ]

    [0 ]

    pr ess [ I nput ]

    [ Al oad1]

    [ 20000 ]

    Load t he wei ght , no l ess t han 50%

    Max, t he cl oser t o F. S, t he

    bet ter i t i s . Press [ i nput ] f or

    conf i r mwhen st abl e l i ght i s on.

    For exampl e: 20000

    W 0 1 2 3

    /S 0.4 0.3 0.2 0.1

    X 0 1 2 3 4 5 6 7 8 9

    NO 0.5e 1.0e 1.5e 2.0e 2.5e 3.0e 3.5e 4.0e 4.5e

    Y,Z 1 2 3 4 5

    F.S 2% 4% 10% 20% 100%

    9 pr ess [ I nput ]

    pr ess [ I nput ]

    pr ess [ I nput ]

    [ H

    ****** ]

    [ C

    ****** ]

    [ CH

    **** ]

    H, C, CH ar e t hr ee cal i br at i on

    coef f i ci ent s, don t modi f y

    t hem, j ust r ecor d t hem. ( I n case

    t hey ar e l ost , i nput t hese val ue

    wi l l r ecover )

    10 pr ess [ 1]

    pr ess [ I nput ]

    [ Adr ** ]

    [ Adr 01]

    Communi cat i on Addr ess ( 01- 26)

    f or exampl e 1

    11 pr ess [ 1 ]

    pr ess [ I nput ]

    [ bt * ]

    [ bt 1 ]

    Band r at e f or ser i al

    communi cat i on : ( 0- 4) i n f or

    600, 1200, 2400, 4800, 9600

    For exampl e: 1 f or 1200

    12 pr ess [ 0 ]

    press

    [ I nput ]

    [ tF * ]

    [ tF 0]

    Communi cat i on Mode :

    0- Cont i nousl y sendi ng

    1- On command

    13 Wei gh

    status

    Cal i br at i on over

    Not e: Tur n t he cal i br at i on

    swi t ch t o l ef t t o f or bi dden

    cal i br at i on, t hen i ndi cat or

    coul d wor k i n wei ghi ng stat us.

  • 8/10/2019 catalog A9

    13/19

    12

    6. Operation

    6. 1 Power on and auto zer o

    A, I f wi t h AC power suppl y, j ust t ur n on power swi t ch; i f wi t h

    DC power suppl y, f i r st connect bat t er y t o i ndi cat or wi t h t he

    cabl e, and turn on power swi t ch and DC power swi t ch. Af t er

    powered on, i ndi cat or wi l l per f orm999999- 000000 sel f check

    and come i nt o wei ghi ng st atus.

    B, Whe power on, i f wei ghs on pl at f or mdevi ates f r omzero poi nt

    but wi t hi n aut o zer o r ange, i ndi cat or wi l l per f or maut o zer o.

    6. 2 Manual l y zero

    A, Pr ess [ Zer o] , i ndi cat or wi l l be back t o zer o, and zer o l i ght

    wi l l be on;

    B, Zer o key wi l l onl y be val i d when wei ghs on pl at f or mi s wi t hi n

    manual zer o range;

    C, Zer o oper at i on i s val i d onl y when st abl e l i ght i s on

    6. 3 Tare oper at i on

    Ther e ar e t hree met hods t o t ar e:

    Method 1, Normal t are

    Press [ t ar e] key when wei ghi ng dat a i s posi t i ve and st abl e,

    t he di spl ayed wei ghi ng dat a wi l l be r egarded as t ar e wei ght ,

    t hen i ndi cat or wi l l di spl ay 0 and t ar e l i ght i s on

    Met hod 2, Pre- t are

    Pr ess [ Pr e t ar e] key at wei ghi ng st at us, i ndi cat or wi l l di spl ay

    [ P **** *] , t he di spl ayed dat a i s t he f or mer t ar e wei ght . I f need

    t o set new t ar e wei ght , j ust i nput by numer i c key, pr ess [ i nput ]

    t o conf i r m.

    Met hod 3, Cal l t ar e wei ght accor di ng to t r uck no.

    Pr ess [ t r uck no. ] at wei ghi ng st at us, i ndi cat or di spl ay [o

    **** *] , i nput t r uck no. by numer i c key, pr ess [ t ar e] key, t hen

    i ndi cat or wi l l f i nd t he cor r espondi ng t ar e wei ght of t he t r uck

    no. f or use.

    At wei ghi ng st at us, cont i nuous t ar e oper at i on i s per mi t t ed.

    When t ar e wei ght i s 0, t hen t ar e l i ght wi l l be of f ; when i ndi cat or

    wi t hi n manual zer o r ange, press [ zero] t o make t are wei ght as

    0, the t are l i ght i s al so of f .

    6. 4 Set f or date and t i me

    A, I ndi cat or di spl ays t he pr esent dat e and dat e

    l i ght i s on i f you push [ Dat e ] key at wei ghi ng st at us.

    I f t he dat e i s cor r ect , you can exi t by pr essi ng

    [ I nput ] or [ wei gh ] key. I f t he dat e i s not cor r ect,

    I nput t he cor r ect date by numer i cal key, t hen pr ess

  • 8/10/2019 catalog A9

    14/19

    13

    [ I nput ] key f or conf i r m.

    B, I ndi cat or di spl ays t he pr esent t i me and t i me

    l i ght i s on i f you push [ t i me ] key at wei ghi ng st at us.

    I f t he t i me i s cor r ect , you can exi t by pr essi ng

    [ I nput ] or [ wei gh ] key. I f t he t i me i s not cor r ect,

    I nput t he cor r ect t i me by numer i cal key, t hen pr ess

    [ I nput ] key f or conf i r m.

    6. 5 Bat t ery usage

    A, Ther e ar e 3 bat t er y l i ght s t o i ndi cat e t he bat t er y el ectr i ci t y.

    The bat t er y el ect r i ci t y i s i nsuf f i ci ent i f onl y one l i ght i s

    on. You shoul d char ge the bat t er y at t hi s t i me. The cont i nual

    use i n t he i nsuf f i ci ent bat t er y status wi l l r esul t i n t he

    power - of f .

    B, You can char ge t he bat t ery by connect i ng t he bat t ery to

    i ndi cat or and tur ni ng on the AC power ( char gi ng t i me i s 30 hour s)

    C, The f i r st t i me t he bat t er y i s used, ensur e char ge f ul l y f or

    bat t er y, t hen use

    D, Red wi r e of cabl e i s t o connect + of bat t ery whi l e bl ack

    wi r e of cabl e i s t o connect - of bat t er y

    6. 6 I nt er nal code di spl ay

    A, The i ndi cat or wi l l di spl ay the i nt er nal code i f you pr ess

    [ pr i nt set ] key and i nput [ 2 ] , [ 8 ] at wei ghi ng st at us, at

    t hi s t i me t he i nt er nal code l i ght i s on. You can exi t t he

    i nt er nal code st at us by pr essi ng [pri nt set ] key agai n, and

    i nput [ 2 ] , [ 8 ] , t he i nt ernal code l i ght wi l l be of f .

    B, At i nt er nal code di spl ay st at us, al l ot her keys ar e i nval i d

    except [ zer o] , [ pr i nt ]

    C, 20 i nt er nal codes i s equal t o one di vi si on

    6. 7 Save operat i on

    A, For t r uck no. , i t s 5- bi t number whi l e f or car go no. , i t s 2- bi t

    number . Max. t r uck no. i s 255 whi l e max. cargo no. i s 100

    B, Each t i me one wei ghi ng r ecor d i s saved, t hen i ndi cat or wi l l

    pr i nt out one wei ghi ng r ecor d( when pr i nt set up i s val i d)

    C, Thr ee are t hree methods t o save

    - Method 1, t wo t i mes wei ghi ng t o consi st of one wei ghi ng r ecor d

    - Method 2, one t i me wei ghi ng t o consi st of one wei ghi ng r ecor d

    when t are wei ght i s known

    - Method 3, what wei ghs i s j ust cargo, t hen one t i me wei ghi ng

    consi st of one wei ghi ng r ecor d.

  • 8/10/2019 catalog A9

    15/19

    14

    Rul e f or di f f er f or above 3 met hods i s as f ol l owed:

    - - When t r uck no. i s 00000, t hen save method i s 3

    - - When t ar e l i ght i s on, t hen save met hod i s 2

    - - When t r uck no. i s any no. except 00000 and t are wei ght i s

    of f , t hen save method i s 1

    D, Save oper at i on i s as f ol l owed t abl e:

    6. 8 Del ete oper at i on

    A, There are t wo methods f or del ete:

    - Met hod 1, del et e al l r ecor ds( i ncl ude t r uck no. and t ar e wei ght )

    - Met hod 2, del et e ont t r uck no. and cor r espondi ng t ar e wei ght ,

    and al l wei ghi ng r ecor ds r el at ed t o t hi s t r uck no.

    B, Operat i on

    - Pr ess [ f un] at wei ghi ng st at us, i t di r ect s t o met hod 1 f or

    del et e;

    - Pr ess [ Tr uck no. ] , i nput t he t r uck no. at wei ghi ng st at us, pr ess

    [ zer o] , i t di r ects met hod 2 t o del et e;

    Dur i ng t he cour se of del et e, i ndi cat or wi l l di spl ay [sur e 0]

    t o i ndi cat e oper at or whet her t o del et e or not , pr ess any key

    except 0 and [ i nput ] f or conf i r m, pr ess 0 and [ i nput ] t o exi t

    6. 9 Save t are wei ght

    A, There are t hr ee methods f or save t ar e wei ght :

    - Met hod 1

    st ep Oper at i on Di spl ay Not e

    1 Press [ pr i nt ] Wei ghi ng

    status2 I nput t r uck no.

    Pr ess [ i nput ][ o *****][ o 03217]

    I nput t r uck

    no. 032173

    I nput car go no.

    Pr ess [ i nput ]

    [ hn **][ hn 35]

    I nput car go

    no. 35

    4I nput [ 10]Pr ess [ i nput ]

    [ BFL **][ BFL 10]

    I nput di scountr at e i nper t ent age: 10%

    Save f i ni shNote1: When wei ghi ng data i s unst abl e, or gross

    wei ght i s 0 or net wei ght i s 0, dat a can t besaved

    Note2, When t r uck no. i s more t han 255, i ndi ct orwi l l di spl ay [err 10]

  • 8/10/2019 catalog A9

    16/19

    15

    - Method 2, Press [ t are save] when unl oaded t r uck i s on and st abl e

    l i ght i s on, i nput t r uck no. t hen pr ess [ i nput ] t o save t ar e

    wei ght

    - Met hod 3, When save a wei ghi ng record, i f t he t ar e wei ght f or

    t he t r uck no. i sn t saved bef or e, t hen r egar d t ar e wei ght at

    t hi s r ecor d as t he t ar e wei ght of t he t r uck.

    6. 10 Sof t ware ver si on check

    Pr ess [ pr i nt set ] and i nput passwor d [ 3] [ 0] , t hen pr ess

    [ i nput ] , i ndi cat or di spl ay [ ver *. **] t o show t he ver si on

    no. Press [ wei gh] back t o wei ghi ng stat us.

    7. Code display

    7. 1 Normal i nf ormat i on

    -

    Wai t a moment , and t hi s i s a normal di spl ay;

    - Prnt

    Wai t a moment , dat a t r ansmi t t ed bet ween i ndi cator and pr i nter

    - LoAd

    St or i ng dat a

    - --OF--

    No meani ng

    7. 2 Er r or code di spl ay

    - Err 03

    Over l oad warni ng

    - Err 19

    Zer o or Negat i ve wei ght val ue, can t be pr i nt ed.

    - Err 11

    Not meet demands of set up f or l i nked f ormat set up

    - Err 12

    Not meet demands of set up f or pr i nt er

    - Err 16

    Dat e or Ti me i l l egal

    - Err 09

    Tr uck no does not exi st

    st ep Oper at i on Di spl ay Not e

    1 Pr ess [ t r uck

    no. ]

    Wei ghi ng

    status

    2 I nput t r uck no.

    Pr ess [ i nput ]

    [ o *****]

    [ o 35790]Exampl e: 35790

    3 I nput t ar ewei ghtPr ess [ i nput ]

    [ p *****][ p 01000]

    Exampl e: 1000

    Save f i ni sh

  • 8/10/2019 catalog A9

    17/19

    16

    - Err 10

    Tr uck no r est or ed exceeds 255

    7. 3 Code f or wr ong set up

    - Err 13

    Wr ong set of t he di vi si on

    - Err 14

    Deci mal poi nt must be l ess t han 5, pl ease r eset t he deci mal

    poi nt

    - Err 15

    Over l oad warni ng must be > 100, pl ease r eset i t

    - Err 17

    Over l oad warni ng must be < 325000, pl ease r eset i t

    7. 3 Code f or wr ong connect i on

    - Err P

    Pri nt er has t r oubl e or i s wr ongl y connect ed, pr ess any

    key to exi t

    - Err 01

    Load cel l connect i on or l oad cel l si gnal has pr obl em

    - Err 02

    Load cel l connect i on or l oad cel l si gnal exceeds A/ D r ange

    - Err 05

    Long- di st ance compensat i on f eedback vol t age i s not cor r ect

    7. 4 Code f or components er r or

    Er r 18

    Key boar d has pr obl ems

    Er r 20

    Dat a par t l y l ost i n RAM

    - Err 21

    Cal i br at i ng dat a l ost i n RAM and E2PROM

    - Err 22

    RAM has been damaged

    - Err 23

    E2PROM has been damaged

    7. 5 Code f or ot hers

    - Err 24

    When i ndi cat or i s at nor mal wor ki ng st at us, cal i br at i on swi t ch

    shoul d be at l ef t , i f when i ndi cat or i s t ur ned on, i ndi cat or

  • 8/10/2019 catalog A9

    18/19

    17

    check t hat cal i br at i on swi t ch i s at r i ght , t hen i t di spl ay Er r

    24 t o i ndi cat e oper at or t o pay at t ent i on

    - Err 25

    I l l egal sof t ware, or E2PROM was damaged

    - ctnu 0

    I ndi cat or wi l l di spl ay t hi s i f i t can not r ecei ve t he stabl e

    dat a wi t hi n 25 seconds dur i ng st ep 8 or st ep 9 of t he cal i br at i on

    pr ocess. At t hi s t i me, t he oper at or can i nput 0, 1 or 2:

    0: ( Abor t ) The i ndi cat or wi l l not do t hi s st ep and ent er next

    st ep

    1: ( Ret r y) Tr y agai n

    2: ( I gnore) The unst abl e dat a can be used

    8. Appendix(For printer type 2,3)

    -Linked-format(3 page)

    -Record format

    Weighing bill Date:1999-07-28

    NO. Ti me Tr uck no. Cago no. Gr o W( kg) Ta W( kg) Net W( kg)

    0002 12. 03. 24 12345 033 2. 000 0. 300 1. 700

    0003 12. 03. 24 00888 033 2. 000 0. 300 1. 700

    0004 12. 04. 11 00888 022 2. 000 0. 300 1. 700

    Accum: Gr oss W: 8. 000(kg) Net W: 6. 800(kg)

    - Filled-in format

    WEI GHT BI LL

    Fi st bi l l f or operat or

    SERI AL No. 123

    DATE 1999-07- 28

    TI ME 12. 35. 28

    VEHI CLE No.

    CARGO No.

    GROSS 1580 kg

    TARE 80 kg

    DI SCOUNT 10 %

    NET 1350 kgREMARK

    -Report print (three copies group by time,truck no. and cargo

    no.)

    NO. 001

    Dat e 1999- 07- 28

    Ti me 12. 02. 31

    Tr no 12345

    Ca no 022

    Gr oss 2. 000(kg)

    Tare 0. 3000( kg)

    Net 1. 7000( kg)

    NO. 001

    Dat e 1999- 07- 28

    Ti me 12. 02. 31

    Tr no 12345

    Ca no 022

    Gr oss 2. 000( kg)

    Tare 0. 3000( kg)

    Net 1. 7000( kg)

    NO. 001

    Dat e 1999- 07- 28

    Ti me 12. 02. 31

    Tr no 12345

    Ca no 022

    Gross 2. 000(kg)

    Tare 0. 3000( kg)

    Net 1. 7000( kg)

  • 8/10/2019 catalog A9

    19/19

    18

    A, Pr ess [pri nt set ] , i ndi cat or di spl ay [ P 00] , pr ess [1] and

    [ i nput ] t o pr i nt r epor t , r epor t dat e i s cur r ent dat e of i ndi cat or .

    The t hree r epor t s ar e as f ol l owed:

    B, Report

    Report 1( by t i me) Date: 1999- 07- 28

    NO. Ti me Truck no. Cago no. Gr o W( kg) Ta W( kg) Net W( kg)

    0002 12. 03. 24 12345 033 2. 000 0. 300 1. 700

    0003 12. 03. 24 00888 033 2. 000 0. 300 1. 700

    0004 12. 04. 11 00888 022 2. 000 0. 300 1. 700

    Accum: Gr oss W: 8. 000(kg) Net W: 6. 800(kg)

    Report 2( by t r uck no. ) Date: 1999- 07- 28

    NO. Truck no. Ta W( kg) Ti me Gr o W( kg) Net W( kg)

    0001 12345 0. 300 0002 4. 000 3. 400

    0002 00888 0. 300 0002 4. 000 3. 400

    Report 3( by cargo no. ) Date: 1999- 07- 28

    NO. Car go no. Ti me Net W( kg)

    0001 022 0002 3. 4000002 033 0002 3. 400

    -Linked-in format(1 page, only for printer type 5)

    No. : 0001

    Date: 02- 03- 14

    Ti me: 10. 57. 27

    Tr uck no: 00001

    Cargo no: 001

    Gr oss W: 10. 00kg

    Tare W: 1. 00kg

    Net W: 9. 00kg

    Tel : 12345678

    - - - - - - - - - - - - - -

    - - - - - - - - - - - - - -

    Tot G. W:

    10. 00kg

    Tot N. W:

    9. 00kg