CAT GENERATOR 3408c and 3412c Maintenence Manual

43
® © 2010 Caterpillar All Rights Reserved ® MAINTENANCE INTERVALS Operation and Maintenance Manual Excerpt

description

Caterpillar Generator

Transcript of CAT GENERATOR 3408c and 3412c Maintenence Manual

Page 1: CAT GENERATOR 3408c and 3412c Maintenence Manual

®© 2010 CaterpillarAll Rights Reserved

®

MAINTENANCE INTERVALSOperation and Maintenance Manual Excerpt

Page 2: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01April 2005

Operation andMaintenanceManual3408C and 3412C Marine GeneratorSetsTAM1-Up (Generator Set)RLR1-Up (Generator Set)

Page 3: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 73Maintenance Section

Maintenance Interval Schedule

i02236669

Maintenance Interval Schedule(3408C Engine)SMCS Code: 1000; 7500

S/N: TAM1-Up

Before performing any operation or maintenanceprocedures, ensure that the safety information,warnings, and instructions are read andunderstood.

Failure to adhere to proper maintenance intervalsmay result in the degradation of the engine’sperformance and/or the accelerated wear of theengine’s components.

Before each consecutive interval is performed, allof the maintenance requirements from the previousinterval must be performed.

When Required

Battery or Battery Cable - Disconnect .................. 79Cooling System Coolant Sample (Level 2) -Obtain ................................................................. 85Engine Air Cleaner Element - Clean/Replace ....... 88Fuel System - Prime ............................................. 97Generator - Dry ................................................... 100Generator Set - Test ........................................... 104Overhaul Considerations .................................... 106Space Heater - Check ......................................... 110

Daily

Air Starting Motor Lubricator Oil Level - Check .... 77Air Tank Moisture and Sediment - Drain ............... 78Cooling System Coolant Level - Check ................ 84Engine Air Cleaner Service Indicator - Inspect ..... 90Engine Oil Level - Check ...................................... 92Fuel Tank Water and Sediment - Drain ................. 99Generator - Inspect ............................................. 102Generator Load - Check ..................................... 103Walk-Around Inspection ....................................... 112

Every Week

Standby Generator Set MaintenanceRecommendations ............................................. 110

Every Year

Generator Set Vibration - Inspect ....................... 104

Every 3800 L (1000 US gal) of Fuel or 50Service Hours

Engine Air Precleaner - Clean .............................. 91

First 13 000 L (3400 US gal) of Fuel or 250Service Hours

Engine Valve Lash - Inspect/Adjust ...................... 95Magnetic Pickups - Clean/Inspect ...................... 106

Every 13 000 L (3400 US gal) of Fuel or 250Service Hours

Battery Charger - Check ....................................... 79Battery Electrolyte Level - Check .......................... 79Belts - Inspect/Adjust/Replace .............................. 79Cooling System Coolant Sample (Level 1) -Obtain ................................................................. 85Cooling System Supplemental Coolant Additive(SCA) - Test/Add ................................................. 86Engine Crankcase Breather - Clean ..................... 91Engine Oil Sample - Obtain .................................. 92Engine Oil and Filter - Change ............................. 93Fan Drive Bearing - Lubricate ............................... 96Fuel System Primary Filter - Clean/Replace ......... 98Fuel System Secondary Filter - Replace .............. 99Hoses and Clamps - Inspect/Replace ................ 105Radiator - Clean .................................................. 109

Every 51 000 L (13 500 US gal) of Fuel or1000 Service Hours

Engine Protection Devices - Calibrate .................. 94Fuel Control Linkage - Check/Lubricate ............... 96

Every 114 000 L (30 000 US gal) of Fuel or3000 Service Hours or 2 Years

Cooling System Coolant Sample (Level 2) -Obtain ................................................................. 85

Every 153 500 L (40 500 US gal) of Fuel or3000 Service Hours

Air Starting Motor Lubricator Bowl - Clean ........... 77Cooling System Coolant (DEAC) - Change .......... 80Cooling System Coolant Extender (ELC) - Add .... 84Cooling System Water Temperature Regulator -Replace ............................................................... 87Crankshaft Vibration Damper - Inspect ................. 87Engine Mounts - Inspect ....................................... 92Engine Valve Lash - Inspect/Adjust ...................... 95Engine Valve Rotators - Inspect ........................... 95Fuel Ratio Control - Inspect/Adjust ....................... 97Turbocharger - Inspect ......................................... 111

Every 256 000 L (67 500 US gal) of Fuel or5000 Service Hours

Alternator - Inspect ............................................... 78Fuel Injection Nozzles - Test/Exchange ................ 96Magnetic Pickups - Clean/Inspect ...................... 106Starting Motor - Inspect ....................................... 111Water Pump - Inspect .......................................... 113

Page 4: CAT GENERATOR 3408c and 3412c Maintenence Manual

74 SEBU7843-01Maintenance SectionMaintenance Interval Schedule

Every 306 000 L (81 000 US gal) of Fuel or6000 Service Hours or 6 Years

Cooling System Coolant (ELC) - Change ............. 82

Page 5: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 75Maintenance Section

Maintenance Interval Schedule

i02236672

Maintenance Interval Schedule(3412C Engine)SMCS Code: 1000; 7500

S/N: RLR1-Up

Before performing any operation or maintenanceprocedures, ensure that the safety information,warnings, and instructions are read andunderstood.

Failure to adhere to proper maintenance intervalsmay result in the degradation of the engine’sperformance and/or the accelerated wear of theengine’s components.

Before each consecutive interval is performed, allof the maintenance requirements from the previousinterval must be performed.

When Required

Battery or Battery Cable - Disconnect .................. 79Cooling System Coolant Sample (Level 2) -Obtain ................................................................. 85Engine Air Cleaner Element - Clean/Replace ....... 88Fuel System - Prime ............................................. 97Generator - Dry ................................................... 100Generator Set - Test ........................................... 104Overhaul Considerations .................................... 106Space Heater - Check ......................................... 110

Daily

Air Starting Motor Lubricator Oil Level - Check .... 77Air Tank Moisture and Sediment - Drain ............... 78Cooling System Coolant Level - Check ................ 84Engine Air Cleaner Service Indicator - Inspect ..... 90Engine Oil Level - Check ...................................... 92Fuel Tank Water and Sediment - Drain ................. 99Generator - Inspect ............................................. 102Generator Load - Check ..................................... 103Walk-Around Inspection ....................................... 112

Every Week

Standby Generator Set MaintenanceRecommendations ............................................. 110

Every Year

Generator Set Vibration - Inspect ....................... 104

Every 3800 L (1000 US gal) of Fuel or 50Service Hours

Engine Air Precleaner - Clean .............................. 91

First 19 000 L (5000 US gal) of Fuel or 250Service Hours

Engine Valve Lash - Inspect/Adjust ...................... 95Magnetic Pickups - Clean/Inspect ...................... 106

Every 19 000 L (5000 US gal) of Fuel or 250Service Hours

Battery Charger - Check ....................................... 79Battery Electrolyte Level - Check .......................... 79Belts - Inspect/Adjust/Replace .............................. 79Cooling System Coolant Sample (Level 1) -Obtain ................................................................. 85Cooling System Supplemental Coolant Additive(SCA) - Test/Add ................................................. 86Engine Crankcase Breather - Clean ..................... 91Engine Oil Sample - Obtain .................................. 92Engine Oil and Filter - Change ............................. 93Fan Drive Bearing - Lubricate ............................... 96Fuel System Primary Filter - Clean/Replace ......... 98Fuel System Secondary Filter - Replace .............. 99Hoses and Clamps - Inspect/Replace ................ 105Radiator - Clean .................................................. 109

Every 76 000 L (20 000 US gal) of Fuel or1000 Service Hours

Engine Protection Devices - Calibrate .................. 94Fuel Control Linkage - Check/Lubricate ............... 96

Every 114 000 L (30 000 US gal) of Fuel or3000 Service Hours or 2 Years

Cooling System Coolant Sample (Level 2) -Obtain ................................................................. 85

Every 228 000 L (60 000 US gal) of Fuel or3000 Service Hours

Air Starting Motor Lubricator Bowl - Clean ........... 77Cooling System Coolant (DEAC) - Change .......... 80Cooling System Coolant Extender (ELC) - Add .... 84Cooling System Water Temperature Regulator -Replace ............................................................... 87Crankshaft Vibration Damper - Inspect ................. 87Engine Mounts - Inspect ....................................... 92Engine Valve Lash - Inspect/Adjust ...................... 95Engine Valve Rotators - Inspect ........................... 95Fuel Ratio Control - Inspect/Adjust ....................... 97Turbocharger - Inspect ......................................... 111

Every 379 000 L (100 000 US gal) of Fuel or5000 Service Hours

Alternator - Inspect ............................................... 78Fuel Injection Nozzles - Test/Exchange ................ 96Magnetic Pickups - Clean/Inspect ...................... 106Starting Motor - Inspect ....................................... 111Water Pump - Inspect .......................................... 113

Page 6: CAT GENERATOR 3408c and 3412c Maintenence Manual

76 SEBU7843-01Maintenance SectionMaintenance Interval Schedule

Every 456 000 L (120 000 US gal) of Fuel or6000 Service Hours or 6 Years

Cooling System Coolant (ELC) - Change ............. 82

Page 7: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 77Maintenance Section

Air Starting Motor Lubricator Bowl - Clean

i02208941

Air Starting Motor LubricatorBowl - CleanSMCS Code: 1451-070

If the engine is equipped with an air starting motor,use the following procedure:

Personal injury can result from removing hoses orfittings in a pressure system.

Failure to relieve pressure can cause personal in-jury.

Do not disconnect or remove hoses or fittings un-til all pressure in the system has been relieved.

1. Ensure that the air supply to the lubricator is OFF.

g00745554Illustration 51(1) Filler plug(2) Bowl(3) Drain valve

2. Slowly loosen filler plug (1) in order to release thepressure from the lubricator.

NOTICECare must be taken to ensure that fluids are containedduring performance of inspection, maintenance, test-ing, adjusting and repair of the product. Be prepared tocollect the fluid with suitable containers before open-ing any compartment or disassembling any compo-nent containing fluids.

Refer to Special Publication, NENG2500, “CaterpillarTools and Shop Products Guide” for tools and suppliessuitable to collect and contain fluids on Caterpillarproducts.

Dispose of all fluids according to local regulations andmandates.

3. Place a suitable container under bowl (2) andopen drain valve (3) in order to drain the oil fromthe bowl.

4. Remove bowl (2). Clean the bowl with warm water.

5. Dry the bowl. Inspect the bowl for cracks. If thebowl is cracked, replace the damaged bowl witha new bowl. Inspect the gasket. If the gasket isdamaged, replace the gasket.

6. Install the bowl.

7. Make sure that drain valve (3) is closed.

8. For instructions on filling the lubricator, see thisOperation and Maintenance Manual, “Air StartingMotor Lubricator Oil Level - Check” topic.

i02213914

Air Starting Motor LubricatorOil Level - CheckSMCS Code: 1451-535

NOTICENever allow the lubricator bowl to become empty. Theair starting motor will be damaged by a lack of lubrica-tion. Ensure that sufficient oil is in the lubricator bowl.

g00745561Illustration 52

1. Observe the oil level in sight gauge (3). If the oillevel is less than 1/2, add oil to the lubricator bowl.

Page 8: CAT GENERATOR 3408c and 3412c Maintenence Manual

78 SEBU7843-01Maintenance SectionAir Tank Moisture and Sediment - Drain

Personal injury can result from removing hoses orfittings in a pressure system.

Failure to relieve pressure can cause personal in-jury.

Do not disconnect or remove hoses or fittings un-til all pressure in the system has been relieved.

2. Ensure that the air supply to the lubricator is OFF.Slowly loosen filler plug (4) in order to releasepressure from the lubricator bowl.

3. Remove filler plug (4). Pour oil into the lubricatorbowl. Use nondetergent SAE 10W oil fortemperatures that are greater than 0 °C (32 °F).Use air tool oil for temperatures that are below0 °C (32 °F).

4. Install filler plug (4).

Adjust the LubricatorNote: Adjust the lubricator with a constant rate of airflow. After the adjustment, the lubricator will releaseoil in proportion to variations of the air flow.

1. Ensure that the fuel supply to the engine is OFF.

NOTICEDo not crank the engine continuously for more than30 seconds. Allow the starting motor to cool for twominutes before cranking the engine again.

2. Operate the air starting motor. Observe the dropsof oil that are released in dome (1).

Note: Some lubricators have an adjustment screwrather than a knob.

3. If necessary, adjust the lubricator in orderto release from one to three drops of oil persecond. To increase the rate, turn knob (2)counterclockwise. To decrease the rate, turn theknob clockwise.

i00847451

Air Tank Moisture andSediment - Drain(If Equipped)SMCS Code: 1466-543-M&S

Moisture and sediment in the air starting system cancause the following conditions:

• Freezing

• Corrosion of internal parts

• Malfunction of the air starting system

When opening the drain valve, wear protectivegloves, a protective face shield, protective cloth-ing, and protective shoes. Pressurized air couldcause debris to be blown and result in personalinjury.

1. Open the drain valve that is on the bottom of theair tank. Allow the moisture and sediment to drain.

2. Close the drain valve.

3. Check the air supply pressure. The air startingmotor requires a minimum of 620 kPa (90 psi) ofair pressure to operate properly. The maximum airpressure must not exceed 1550 kPa (225 psi).The normal air pressure will be 758 to 965 kPa(110 to 140 psi).

i00072207

Alternator - InspectSMCS Code: 1405-040

Caterpillar recommends a scheduled inspectionof the alternator. Inspect the alternator for looseconnections and proper battery charging. Inspect theammeter (if equipped) during engine operation inorder to ensure proper battery performance and/orproper performance of the electrical system. Makerepairs, as required. Refer to the Service Manual.

Check the alternator and the battery charger forproper operation. If the batteries are properlycharged, the ammeter reading should be very nearzero. All batteries should be kept charged. Thebatteries should be kept warm because temperatureaffects the cranking power. If the battery is too cold,the battery will not crank the engine. The battery willnot crank the engine, even if the engine is warm.When the engine is not run for long periods of timeor if the engine is run for short periods, the batteriesmay not fully charge. A battery with a low charge willfreeze more easily than a battery with a full charge.

Page 9: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 79Maintenance Section

Battery Charger - Check

i01942625

Battery Charger - CheckSMCS Code: 1401-535

Check the battery charger for proper operation. Ifthe batteries are properly charged, the needle of theammeter will register near “0” (zero).

The batteries should be kept warm, when possible.The temperature of the battery will affect crankingpower. A battery that is too cold will not crank theengine, even if the engine is warm.

The batteries may not fully recharge when the engineis not run for long periods of time. The batteries maynot fully recharge if the engine only runs for shortperiods. Ensure a full charge in order to help preventthe battery from freezing.

i02213936

Battery Electrolyte Level -CheckSMCS Code: 1401-535

When the engine is not run for long periods of time orwhen the engine is run for short periods, the batteriesmay not fully recharge. Ensure a full charge in orderto help prevent the battery from freezing. If batteriesare properly charged, ammeter reading should bevery near zero.

All lead-acid batteries contain sulfuric acid whichcan burn the skin and clothing. Always wear a faceshield and protective clothing when working on ornear batteries.

1. Remove the filler caps. Maintain the electrolytelevel to the “FULL” mark on the battery.

If the addition of water is necessary, use distilledwater. If distilled water is not available use cleanwater that is low in minerals. Do not use artificiallysoftened water.

2. Check the condition of the electrolyte with the245-5829 Coolant Battery Tester Refractometer.

3. Keep the batteries clean.

Clean the battery case with one of the followingcleaning solutions:

• A mixture of 0.1 kg (0.2 lb) of baking soda and1 L (1 qt) of clean water

• A mixture of 0.1 L (0.11 qt) of ammonia and 1 L(1 qt) of clean water

Thoroughly rinse the battery case with clean water.

Use a fine grade of sandpaper to clean theterminals and the cable clamps. Clean the itemsuntil the surfaces are bright or shiny. DO NOTremove material excessively. Excessive removalof material can cause the clamps to not fit properly.Coat the clamps and the terminals with 5N-5561Silicone Lubricant, petroleum jelly or MPGM.

i01492654

Battery or Battery Cable -DisconnectSMCS Code: 1402-029

The battery cables or the batteries should not beremoved with the battery cover in place. The bat-tery cover should be removed before any servic-ing is attempted.

Removing the battery cables or the batteries withthe cover in place may cause a battery explosionresulting in personal injury.

1. Turn the start switch to the OFF position. Turn theignition switch (if equipped) to the OFF positionand remove the key and all electrical loads.

2. Disconnect the negative battery terminal at thebattery that goes to the start switch. Ensure thatthe cable cannot contact the terminal. When four12 volt batteries are involved, the negative side oftwo batteries must be disconnected.

3. Tape the leads in order to help prevent accidentalstarting.

4. Proceed with necessary system repairs. Reversethe steps in order to reconnect all of the cables.

i02154849

Belts - Inspect/Adjust/ReplaceSMCS Code: 1357-025; 1357-040; 1357-510

InspectionInspect the alternator belt and the fan drive belts forwear and for cracking. Replace the belts if the beltsare not in good condition.

Page 10: CAT GENERATOR 3408c and 3412c Maintenence Manual

80 SEBU7843-01Maintenance SectionCooling System Coolant (DEAC) - Change

Check the belt tension according to the information inthe Service Manual, “Specifications”.

Slippage of loose belts can reduce the efficiencyof the driven components. Vibration of loose beltscan cause unnecessary wear on the followingcomponents:

• Belts

• Pulleys

• Bearings

If the belts are too tight, unnecessary stress is placedon the components. This reduces the service life ofthe components.

Adjusting the Alternator Belt

g01092641Illustration 53(1) Mounting bolt(2) Adjusting nuts(3) Mounting bolt

1. Remove the drive belt guard.

2. Loosen mounting bolt (1), adjusting nuts (2) andmounting bolt (3).

3. Turn adjusting nuts (2) in order to increase ordecrease the drive belt tension.

4. Tighten adjusting nuts (2). Tighten mounting bolt(3). Tighten mounting bolt (1). For the propertorque, see the Service Manual, “Specifications”module.

5. Reinstall the drive belt guard.

If new drive belts are installed, check the drive belttension again after 30 minutes of engine operation atthe rated rpm.

Adjusting the Fan Drive Belt1. Loosen the mounting bolt for the pulley.

2. Loosen the adjusting nut for the pulley.

3. Move the pulley in order to adjust the belt tension.

4. Tighten the adjusting nut.

5. Tighten the mounting bolt.

ReplacementFor applications that require multiple drive belts,replace the drive belts in matched sets. Replacingone drive belt of a matched set will cause the newdrive belt to carry more load because the older drivebelts are stretched. The additional load on the newdrive belt could cause the new drive belt to fail.

i02139869

Cooling System Coolant(DEAC) - ChangeSMCS Code: 1350-070; 1395-044

Clean the cooling system and flush the coolingsystem before the recommended maintenanceinterval if the following conditions exist:

• The engine overheats frequently.

• Foaming is observed.

• The oil has entered the cooling system and thecoolant is contaminated.

• The fuel has entered the cooling system and thecoolant is contaminated.

NOTICEUse of commercially available cooling system clean-ers may cause damage to cooling system compo-nents. Use only cooling system cleaners that are ap-proved for Caterpillar engines.

Note: Inspect the water pump and the watertemperature regulator after the cooling system hasbeen drained. This is a good opportunity to replacethe water pump, the water temperature regulator andthe hoses, if necessary.

Page 11: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 81Maintenance Section

Cooling System Coolant (DEAC) - Change

Drain

Pressurized System: Hot coolant can cause seri-ous burns. To open the cooling system filler cap,stop the engine and wait until the cooling systemcomponents are cool. Loosen the cooling systempressure cap slowly in order to relieve the pres-sure.

1. Stop the engine and allow the engine to cool.Loosen the cooling system filler cap slowly inorder to relieve any pressure. Remove the coolingsystem filler cap.

2. Open the cooling system drain valve (if equipped).If the cooling system is not equipped with a drainvalve, remove one of the drain plugs.

Note: If equipped, be sure to drain the heater andany related supply and return lines.

Allow the coolant to drain.

NOTICEDispose of used engine coolant properly or recycle.Various methods have been proposed to reclaim usedcoolant for reuse in engine cooling systems. The fulldistillation procedure is the only method acceptable byCaterpillar to reclaim the used coolant.

For information regarding the disposal and therecycling of used coolant, consult your Caterpillardealer or consult Caterpillar Dealer Service ToolGroup:

Outside Illinois: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOL

Flush1. Flush the cooling system with clean water in orderto remove any debris.

2. Close the drain valve (if equipped). Clean thedrain plugs. Install the drain plugs. Refer to theSpecifications Manual, SENR3130, “TorqueSpecifications” for more information on the propertorques.

NOTICEFill the cooling system no faster than 19 L (5 US gal)per minute to avoid air locks.

3. Fill the cooling system with a mixture of cleanwater and Caterpillar Fast Acting Cooling SystemCleaner. Add 0.5 L (1 pint) of cleaner per 15 L(4 US gal) of the cooling system capacity. Installthe cooling system filler cap.

4. Start and run the engine at low idle for a minimumof 30 minutes. The coolant temperature should beat least 82 °C (180 °F).

NOTICEImproper or incomplete rinsing of the cooling systemcan result in damage to copper and other metal com-ponents.

To avoid damage to the cooling system, make sureto completely flush the cooling system with clear wa-ter. Continue to flush the system until all signs of thecleaning agent are gone.

5. Stop the engine and allow the engine to cool.Loosen the cooling system filler cap slowlyin order to relieve any pressure. Remove thecooling system filler cap. Open the drain valve (ifequipped) or remove the cooling system drainplugs. Allow the water to drain. Flush the coolingsystem with clean water. If equipped, be sure toflush the heater and any related supply and returnlines. Close the drain valve (if equipped). Cleanthe drain plugs. Install the drain plugs. Refer tothe Specifications Manual, SENR3130, “TorqueSpecifications” for more information on the propertorques.

Cooling Systems with HeavyDeposits or PluggingNote: For the following procedure to be effective,there must be some active flow through the coolingsystem components.

1. Flush the cooling system with clean water in orderto remove any debris.

Note: If equipped, be sure to flush the heater andany related supply and return lines.

2. Close the drain valve (if equipped). Clean thedrain plugs. Install the drain plugs. Refer to theSpecifications Manual, SENR3130, “TorqueSpecifications” for more information on the propertorques.

NOTICEFill the cooling system no faster than 19 L (5 US gal)per minute to avoid air locks.

Page 12: CAT GENERATOR 3408c and 3412c Maintenence Manual

82 SEBU7843-01Maintenance SectionCooling System Coolant (ELC) - Change

3. Fill the cooling system with a mixture of cleanwater and Caterpillar Fast Acting Cooling SystemCleaner. Add 0.5 L (1 pint) of cleaner per3.8 to 7.6 L (1 to 2 US gal) of the cooling systemcapacity. Install the cooling system filler cap.

4. Start and run the engine at low idle for a minimumof 90 minutes. The coolant temperature should beat least 82 °C (180 °F).

NOTICEImproper or incomplete rinsing of the cooling systemcan result in damage to copper and other metal com-ponents.

To avoid damage to the cooling system, make sureto completely flush the cooling system with clear wa-ter. Continue to flush the system until all signs of thecleaning agent are gone.

5. Stop the engine and allow the engine to cool.Loosen the cooling system filler cap slowlyin order to relieve any pressure. Remove thecooling system filler cap. Open the drain valve (ifequipped) or remove the cooling system drainplugs. Allow the water to drain. Flush the coolingsystem with clean water. Close the drain valve(if equipped). Clean the drain plugs. Install thedrain plugs. Refer to the Specifications Manual,SENR3130, “Torque Specifications” for moreinformation on the proper torques.

Fill

NOTICEFill the cooling system no faster than 19 L (5 US gal)per minute to avoid air locks.

1. Fill the cooling system with coolant/antifreeze.Refer to the Operation and Maintenance Manual,“Refill Capacitites and Recommendations” topic(Maintenance Section) for more information oncooling system specifications. Do not install thecooling system filler cap.

2. Start and run the engine at low idle. Increase theengine rpm to 1500 rpm. Run the engine at highidle for one minute in order to purge the air fromthe cavities of the engine block. Stop the engine.

3. Check the coolant level. Maintain the coolant levelwithin 13 mm (0.5 inch) below the bottom of thepipe for filling. Maintain the coolant level within13 mm (0.5 inch) to the proper level on the sightglass (if equipped).

4. Clean the cooling system filler cap. Inspect thegasket that is on the cooling system filler cap. Ifthe gasket that is on the cooling system filler capis damaged, discard the old cooling system fillercap and install a new cooling system filler cap.If the gasket that is on the cooling system fillercap is not damaged, perform a pressure test. A9S-8140 Pressurizing Pump is used to performthe pressure test. The correct pressure for thecooling system filler cap is stamped on the face ofthe cooling system filler cap. If the cooling systemfiller cap does not retain the correct pressure,install a new cooling system filler cap.

5. Start the engine. Inspect the cooling system forleaks and for proper operating temperature.

i02173402

Cooling System Coolant (ELC)- ChangeSMCS Code: 1350-070; 1395-044

Clean the cooling system and flush the coolingsystem before the recommended maintenanceinterval if the following conditions exist:

• The engine overheats frequently.

• Foaming is observed.

• The oil has entered the cooling system and thecoolant is contaminated.

• The fuel has entered the cooling system and thecoolant is contaminated.

Note: When the cooling system is cleaned, onlyclean water is needed when the ELC is drained andreplaced.

Note: Inspect the water pump and the watertemperature regulator after the cooling system hasbeen drained. This is a good opportunity to replacethe water pump, the water temperature regulator andthe hoses, if necessary.

Drain

Pressurized System: Hot coolant can cause seri-ous burns. To open the cooling system filler cap,stop the engine and wait until the cooling systemcomponents are cool. Loosen the cooling systempressure cap slowly in order to relieve the pres-sure.

Page 13: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 83Maintenance Section

Cooling System Coolant (ELC) - Change

1. Stop the engine and allow the engine to cool.Loosen the cooling system filler cap slowly inorder to relieve any pressure. Remove the coolingsystem filler cap.

2. Open the cooling system drain valve (if equipped).If the cooling system is not equipped with a drainvalve, remove the cooling system drain plugs.

Allow the coolant to drain.

NOTICEDispose of used engine coolant properly or recycle.Various methods have been proposed to reclaim usedcoolant for reuse in engine cooling systems. The fulldistillation procedure is the only method acceptable byCaterpillar to reclaim the used coolant.

For information regarding the disposal and therecycling of used coolant, consult your Caterpillardealer or consult Caterpillar Dealer Service ToolGroup:

Outside Illinois: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOL

Flush1. Flush the cooling system with clean water in orderto remove any debris.

Note: If equipped, be sure to flush the heater andany related supply and return lines.

2. Close the drain valve (if equipped). Clean thedrain plugs. Install the drain plugs. For theproper torque, refer to the Specifications Manual,SENR3130, “Torque Specifications”.

NOTICEFill the cooling system no faster than 19 L (5 US gal)per minute to avoid air locks.

3. Fill the cooling system with clean water. Install thecooling system filler cap.

4. Start and run the engine at low idle until thetemperature reaches 49 to 66 °C (120 to 150 °F).

5. Stop the engine and allow the engine to cool.Loosen the cooling system filler cap slowlyin order to relieve any pressure. Remove thecooling system filler cap. Open the drain valve (ifequipped) or remove the cooling system drainplugs. Allow the water to drain. Flush the coolingsystem with clean water. Close the drain valve(if equipped). Clean the drain plugs. Install thedrain plugs. For the proper torque, refer to theSpecifications Manual, SENR3130, “TorqueSpecifications”.

Fill

NOTICEFill the cooling system no faster than 19 L (5 US gal)per minute to avoid air locks.

1. Fill the cooling system with Extended Life Coolant(ELC). See Special Publication, SEBU6385,“Caterpillar On-highway Diesel Truck EngineFluids Recommendations” for more information oncooling system specifications. Do not install thecooling system filler cap.

2. Start and run the engine at low idle. Increase theengine rpm to high idle. Run the engine at highidle for one minute in order to purge the air fromthe cavities of the engine block. Stop the engine.

3. Check the coolant level. Maintain the coolant levelwithin 13 mm (0.5 inch) below the bottom of thepipe for filling. Maintain the coolant level within13 mm (0.5 inch) to the proper level on the sightglass (if equipped).

4. Clean the cooling system filler cap. Inspect thegasket that is on the cooling system filler cap. Ifthe gasket that is on the cooling system filler capis damaged, discard the old cooling system fillercap and install a new cooling system filler cap. Ifthe gasket that is on the cooling system filler cap isnot damaged, use a 9S-8140 Pressurizing Pumpin order to pressure test the cooling system fillercap. The correct pressure for the cooling systemfiller cap is stamped on the face of the coolingsystem filler cap. If the cooling system filler capdoes not retain the correct pressure, install a newcooling system filler cap.

5. Start the engine. Inspect the cooling system forleaks and for proper operating temperature.

Page 14: CAT GENERATOR 3408c and 3412c Maintenence Manual

84 SEBU7843-01Maintenance SectionCooling System Coolant Extender (ELC) - Add

i02285855

Cooling System CoolantExtender (ELC) - AddSMCS Code: 1352-045; 1395-081

Cat ELC (Extended Life Coolant) does not requirethe frequent Supplemental Coolant Additive (SCA)additions which are associated with the presentconventional coolants. The Extender only needs tobe added once.

Check the cooling system only when the engine isstopped and cool.

1. Loosen the cooling system filler cap slowly inorder to relieve pressure. Remove the coolingsystem filler cap.

2. It may be necessary to drain enough coolant fromthe cooling system in order to add the Extender.

3. Add Extender according to the requirements foryour engine’s cooling system capacity. Referto the Operation and Maintenance Manual,“Refill Capacities and Recommendations” inthe Maintenance Section for more informationconcerning the Cat ELC Extender additions.

4. Clean the cooling system filler cap. Inspect thegaskets on the cooling system filler cap. Replacethe cooling system filler cap if the gaskets aredamaged. Install the cooling system filler cap.

i01197583

Cooling System Coolant Level- CheckSMCS Code: 1395-082

Check the coolant level when the engine is stoppedand cool.

g00285520Illustration 54Cooling system filler cap

Pressurized System: Hot coolant can cause seri-ous burns. To open the cooling system filler cap,stop the engine and wait until the cooling systemcomponents are cool. Loosen the cooling systempressure cap slowly in order to relieve the pres-sure.

1. Remove the cooling system filler cap slowly inorder to relieve pressure.

2. Maintain the coolant level within 13 mm (0.5 inch)of the bottom of the filler pipe. If the engine isequipped with a sight glass, maintain the coolantlevel to the proper level in the sight glass.

g00103639Illustration 55

Typical filler cap gaskets

3. Clean the cooling system filler cap and check thecondition of the filler cap gaskets. Replace thecooling system filler cap if the filler cap gaskets aredamaged. Reinstall the cooling system filler cap.

4. Inspect the cooling system for leaks.

Page 15: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 85Maintenance Section

Cooling System Coolant Sample (Level 1) - Obtain

i02326688

Cooling System CoolantSample (Level 1) - ObtainSMCS Code: 1350-008; 1395-008; 1395-554; 7542

Note: Obtaining a Coolant Sample (Level 1) isoptional if the cooling system is filled with CatELC (Extended Life Coolant). Cooling systems thatare filled with Cat ELC should have a Coolant Sample(Level 2) that is obtained at the recommended intervalthat is stated in the Maintenance Interval Schedule.

Note: Obtain a Coolant Sample (Level 1) if thecooling system is filled with any other coolantinstead of Cat ELC. This includes the followingtypes of coolants.

Table 15

Recommended Interval

Type of Coolant Level 1 Level 2

Cat DEAC Every 250Hours(1) Yearly(1)(2)

Cat ELC Optional(2) Yearly(2)

(1) This is the recommended interval for coolant samples for allconventional heavy-duty coolant/antifreeze. This is also therecommended interval for coolant samples of commercialcoolants that meet the Cat EC-1 specification for enginecoolant.

(2) The Level 2 Coolant Analysis should be performed sooner if aproblem is suspected or identified.

• Commercial long life coolants that meet theCaterpillar Engine Coolant Specification -1(Caterpillar EC-1)

• Cat DEAC (Diesel Engine Antifreeze/Coolant)

• Commercial heavy-duty coolant/antifreeze

NOTICEAlways use a designated pump for oil sampling, anduse a separate designated pump for coolant sampling.Using the same pump for both types of samples maycontaminate the samples that are being drawn. Thiscontaminate may cause a false analysis and an incor-rect interpretation that could lead to concerns by bothdealers and customers.

Note: Level 1 results may indicate a need forLevel 2 Analysis.

Obtain the sample of the coolant as close as possibleto the recommended sampling interval. In orderto receive the full effect of S·O·S analysis, youmust establish a consistent trend of data. In orderto establish a pertinent history of data, performconsistent samplings that are evenly spaced.Supplies for collecting samples can be obtained fromyour Caterpillar dealer.

Use the following guidelines for proper sampling ofthe coolant:

• Complete the information on the label for thesampling bottle before you begin to take thesamples.

• Keep the unused sampling bottles stored in plasticbags.

• Obtain coolant samples directly from the coolantsample port. You should not obtain the samplesfrom any other location.

• Keep the lids on empty sampling bottles until youare ready to collect the sample.

• Place the sample in the mailing tube immediatelyafter obtaining the sample in order to avoidcontamination.

• Never collect samples from expansion bottles.

• Never collect samples from the drain for a system.

Submit the sample for Level 1 analysis.

For additional information about coolant analysis,see Special Publication, SEBU6251, “CaterpillarCommercial Diesel Engine Fluids Recommendations”or consult your Caterpillar dealer.

i01987714

Cooling System CoolantSample (Level 2) - ObtainSMCS Code: 1350-008; 1395-008; 1395-554; 7542

NOTICEAlways use a designated pump for oil sampling, anduse a separate designated pump for coolant sampling.Using the same pump for both types of samples maycontaminate the samples that are being drawn. Thiscontaminate may cause a false analysis and an incor-rect interpretation that could lead to concerns by bothdealers and customers.

Refer to Operation and Maintenance Manual,“Cooling System Coolant Sample (Level 1) - Obtain”for the guidelines for proper sampling of the coolant.

Page 16: CAT GENERATOR 3408c and 3412c Maintenence Manual

86 SEBU7843-01Maintenance SectionCooling System Supplemental Coolant Additive (SCA) - Test/Add

Submit the sample for Level 2 analysis.

For additional information about coolantanalysis, see Special Publication, SEBU6251,“Caterpillar Commercial Diesel Engines FluidsRecommendations” or consult your Caterpillar dealer.

i02093741

Cooling System SupplementalCoolant Additive (SCA) -Test/AddSMCS Code: 1352-045; 1395-081

This maintenance procedure is required forconventional coolants such as DEAC and formixtures of water and SCA. This maintenance isNOT required for cooling systems that are filledwith Extended Life Coolant.

Cooling system coolant additive contains alkali.To help prevent personal injury, avoid contact withthe skin and eyes. Do not drink cooling systemcoolant additive.

Note: Caterpillar recommends an S·O·S coolantanalysis (Level 1).

Test the Concentration of the SCA

Coolant/Antifreeze and SCA

NOTICEDo not exceed the recommended six percent supple-mental coolant additive concentration.

Test the concentration of the SCA with the 8T-5296Coolant Conditioner Test Kit.

Water and SCA

NOTICEDo not exceed the recommended eight percent sup-plemental coolant additive concentration.

Test the concentration of the SCA with the 8T-5296Coolant Conditioner Test Kit. Use the instructionsthat follow:

1. Fill the syringe to the “1.0 ml” mark with thecoolant.

2. Dispense the 1.0 mL coolant sample from thesyringe into the empty mixing bottle.

3. Add tap water to the mixing bottle in order to bringthe level up to the “10 ml” mark. Place the cap onthe bottle and shake the bottle.

4. Add 2 to 3 drops of the “NITRITE INDICATORSOLUTION B” to the mixing bottle. Move the bottlein a circular motion in order to mix the solution.

5. Add 1 drop of “NITRITE TEST SOLUTION A” tothe mixing bottle. Move the bottle in a circularmotion in order to mix the solution.

6. Repeat 5 until the solution changes color from redto light gray, green, or blue. Record the number ofdrops of “NITRITE TEST SOLUTION A” that wererequired to cause the color change.

7. Use Table 16 to interpret the results.

Table 16

Number ofDrops

Concentrationof SCA

MaintenanceRequired

Less than 25 Less than therecommendedconcentration ofSCA

Add SCA.Retest thecoolant.

25 to 30 Therecommendedconcentration ofSCA

None

More than 30 More than therecommendedconcentration ofSCA

Remove thecoolant.Replace withwater onlyRetest thecoolant.

Add the SCA, If Necessary

Pressurized System: Hot coolant can cause seri-ous burns. To open the cooling system filler cap,stop the engine and wait until the cooling systemcomponents are cool. Loosen the cooling systempressure cap slowly in order to relieve the pres-sure.

1. Remove the cooling system filler cap slowly.

Note: Always dispose of fluids according to localregulations.

2. If necessary, drain some coolant in order to allowspace for the addition of the SCA.

Page 17: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 87Maintenance Section

Cooling System Water Temperature Regulator - Replace

NOTICEExcessive supplemental coolant additive concentra-tion can form deposits on the higher temperature sur-faces of the cooling system, reducing the engine’sheat transfer characteristics. Reduced heat transfercould cause cracking of the cylinder head and otherhigh temperature components.

Excessive supplemental coolant additive concentra-tion could also result in blockage of the heat exchang-er, overheating, and/or accelerated wear of the waterpump seal.

Do not exceed the recommended amount of supple-mental coolant additive concentration.

3. Add the proper amount of SCA. For theproper amount of SCA, refer to this Operationand Maintenance Manual, “Refill Capacitiesand Recommendations” topic. The properconcentration of SCA depends on the type ofcoolant that is used. For the proper concentrationof SCA, refer to Special Publication, SEBU6251,“Caterpillar Commercial Diesel Engine FluidsRecommendations”.

4. Clean the cooling system filler cap. Install thecooling system filler cap.

i00912898

Cooling System WaterTemperature Regulator -ReplaceSMCS Code: 1355-510

Replace the water temperature regulator beforethe water temperature regulator fails. This is arecommended preventive maintenance practice.Replacing the water temperature regulator reducesthe chances for unscheduled downtime.

A water temperature regulator that fails in apartially opened position can cause overheating orovercooling of the engine.

A water temperature regulator that fails in the closedposition can cause excessive overheating. Excessiveoverheating could result in cracking of the cylinderhead or piston seizure problems.

A water temperature regulator that fails in the openposition will cause the engine operating temperatureto be too low during partial load operation. Lowengine operating temperatures during partial loadscould cause an excessive carbon buildup inside thecylinders. This excessive carbon buildup could resultin an accelerated wear of the piston rings and wearof the cylinder liner.

NOTICEFailure to replace your water temperature regulatoron a regularly scheduled basis could cause severeengine damage.

Caterpillar engines incorporate a shunt design coolingsystem and require operating the engine with a watertemperature regulator installed.

If the water temperature regulator is installed incor-rectly, the enginemay overheat, causing cylinder headdamage. Ensure that the new water temperature reg-ulator is installed in the original position. Ensure thatthe water temperature regulator vent hole is open.

Do not use liquid gasket material on the gasket orcylinder head surface.

Refer to the Service Manual for the replacementprocedure of the water temperature regulator, orconsult your Caterpillar dealer.

Note: If only the water temperature regulators arereplaced, drain the coolant from the cooling system toa level that is below the water temperature regulatorhousing.

i00894991

Crankshaft Vibration Damper- InspectSMCS Code: 1205-040

Damage to the crankshaft vibration damper or failureof the crankshaft vibration damper can increasetorsional vibrations. This can result in damage tothe crankshaft and to other engine components. Adeteriorating damper can cause excessive gear trainnoise at variable points in the speed range.

The damper is mounted to the crankshaft which islocated behind the belt guard on the front of theengine.

Rubber DamperYour engine may be equipped with a rubber damper.The rubber damper uses a ring which is mounted inrubber in order to reduce vibrations in the crankshaft.

Page 18: CAT GENERATOR 3408c and 3412c Maintenence Manual

88 SEBU7843-01Maintenance SectionEngine Air Cleaner Element - Clean/Replace

Inspect the damper and repair or replace the damperfor any of the following reasons:

• There is deterioration and cracking of the rubber.

• There is slippage of the outer ring from the originalposition.

• The engine has had a failure because of a brokencrankshaft.

• Analysis of the oil has revealed that the front mainbearing is badly worn.

• There is a large amount of gear train wear that isnot caused by lack of oil.

Refer to the Service Manual or consult yourCaterpillar dealer for information about damperreplacement.

Visconic DamperYour engine may be equipped with a visconicdamper. The visconic damper has a weight that islocated inside a fluid filled case. The weight moves inthe case in order to limit torsional vibration.

Inspect the damper for evidence of fluid leaks. Ifa fluid leak is found, determine the type of fluid.The fluid in the damper is silicone. Silicone hasthe following characteristics: transparent, viscous,smooth, and difficult to remove from surfaces.

If the fluid leak is oil, inspect the crankshaft seals forleaks. If a leak is observed, replace the crankshaftseals.

Inspect the damper and repair or replace the damperfor any of the following reasons:

• The damper is dented, cracked, or leaking.

• The paint on the damper is discolored from heat.

• The engine has had a failure because of a brokencrankshaft.

• Analysis of the oil has revealed that the front mainbearing is badly worn.

• There is a large amount of gear train wear that isnot caused by a lack of oil.

Refer to the Service Manual or consult yourCaterpillar dealer for information about damperreplacement.

i01943356

Engine Air Cleaner Element -Clean/ReplaceSMCS Code: 1054-070; 1054-510

NOTICENever run the engine without an air cleaner elementinstalled. Never run the engine with a damaged aircleaner element. Do not use air cleaner elements withdamaged pleats, gaskets or seals. Dirt entering theengine causes premature wear and damage to enginecomponents. Air cleaner elements help to prevent air-borne debris from entering the air inlet.

NOTICENever service the air cleaner element with the enginerunning since this will allow dirt to enter the engine.

Servicing the Air Cleaner ElementsIf the air cleaner element becomes plugged, the airpressure can split the filter material of the element.Unfiltered air will drastically accelerate internalengine wear. Your Caterpillar dealer has the properair cleaner elements for your application.

The air cleaner may be mounted high above theengine. If necessary, use a ladder or a platform toreach the air cleaner.

• Check the precleaner (if equipped) daily foraccumulation of dirt and debris. Remove any dirtand debris, as needed.

• Operating conditions (dust, dirt and debris) mayrequire more frequent service of the air cleanerelement.

• The air cleaner element may be cleaned up tosix times if the element is properly cleaned andinspected.

• The air cleaner element should be replaced at leastone time per year. This replacement should beperformed regardless of the number of cleanings.

Replace the dirty paper elements with cleanelements. Before installation, thoroughly inspect theelement for tears and/or holes in the filter material.Inspect the gasket or the seal of the element fordamage. Maintain a supply of suitable elements forreplacement purposes.

Page 19: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 89Maintenance Section

Engine Air Cleaner Element - Clean/Replace

g00317608Illustration 56Fasteners for the air cleaner cover

g00781084Illustration 57(1) Cover(2) Element(3) Air inlet

1. Release the fasteners for cover (1).

2. Remove the cover and element (2).

3. Cover air inlet (3) with tape in order to keep dirtout.

4. Clean the inside of the cover and the body witha clean, dry cloth.

5. Remove the tape for the air inlet. Install a newelement or a clean element.

6. Install the cover.

7. If necessary, reset the air cleaner service indicator.

Cleaning the Primary Air CleanerElementsThe primary air cleaner element can be used upto six times if the element is properly cleaned andinspected. When the element is cleaned, check thefilter material for rips or tears. Replace the elementat least one time per year regardless of the numberof cleanings.

Use clean elements while dirty elements are beingcleaned.

NOTICEDo not clean the air cleaner elements by bumping ortapping. This could damage the seals. Do not use el-ements with damaged pleats, gaskets or seals. Dam-aged elements will allow dirt to pass through. Enginedamage could result.

Visually inspect the elements before cleaning. Inspectthe elements for damage to the seal, the gaskets,and the outer cover. Discard any damaged elements.

Air cleaner elements can be cleaned with pressurizedair and with a vacuum.

Pressurized Air

Pressurized air can be used to clean elementsthat have not been cleaned more than two times.Pressurized air will not remove deposits of carbonand oil. Use filtered, dry air with a maximum pressureof 207 kPa (30 psi).

g00281692Illustration 58

Note:When the elements are cleaned, always beginwith the clean side (inside) in order to force dirtparticles toward the dirty side (outside).

Aim the hose so that the air flows inside the elementalong the length of the filter in order to help preventdamage to the paper pleats. Do not aim the streamof air directly at the primary air cleaner element. Dirtcould be forced into the pleats.

Page 20: CAT GENERATOR 3408c and 3412c Maintenence Manual

90 SEBU7843-01Maintenance SectionEngine Air Cleaner Service Indicator - Inspect

Note: Refer to “Inspecting the Primary Air CleanerElements”.

Vacuum Cleaning

Vacuum cleaning is a good method for cleaningelements which require daily cleaning because of adry, dusty environment. Cleaning with pressurized airis recommended prior to vacuum cleaning. Vacuumcleaning will not remove deposits of carbon and oil.

Note: Refer to “Inspecting the Primary Air CleanerElements”.

Inspecting the Primary Air CleanerElements

g00281693Illustration 59

Inspect the clean, dry element. Use a 60 watt bluelight in a dark room or in a similar facility. Placethe blue light in the element. Rotate the element.Inspect the element for tears and/or holes. Inspectthe element for light that may show through the filtermaterial. If it is necessary in order to confirm theresult, compare the element to a new element thathas the same part number.

Do not use an element that has any tears and/orholes in the filter material. Do not use an element withdamaged pleats, gaskets or seals. Discard damagedelements.

Storing Primary Air Cleaner Elements

If an element that passes inspection will not be usedimmediately, store the element for future use.

g00281694Illustration 60

Do not use paint, a waterproof cover, or plastic as aprotective covering for storage. Restricted air flowmay result. To protect against dirt and damage, wrapthe elements in Volatile Corrosion Inhibited (VCI)paper.

Place the element into a cardboard box for storage.For identification, mark the outside of the containerand mark the element. Include the followinginformation:

• Date of cleaning

• Number of cleanings

Store the container in a dry location.

For more detailed information on cleaning the primaryair cleaner element, refer to Special Publication,SEBF8062, “Procedure to Inspect and Clean AirFilters”.

i01900118

Engine Air Cleaner ServiceIndicator - Inspect(If Equipped)SMCS Code: 7452-040

Some engines may be equipped with a differentservice indicator.

Some engines are equipped with a differential gaugefor inlet air pressure. The differential gauge for inletair pressure displays the difference in the pressurethat is measured before the air cleaner element andthe pressure that is measured after the air cleanerelement. As the air cleaner element becomes dirty,the pressure differential rises. If your engine isequipped with a different type of service indicator,follow the OEM recommendations in order to servicethe air cleaner service indicator.

Page 21: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 91Maintenance Section

Engine Air Precleaner - Clean

The service indicator may be mounted on the aircleaner housing or in a remote location.

g00103777Illustration 61Typical service indicator

Observe the service indicator. The air cleanerelement should be cleaned or the air cleaner elementshould be replaced when one of the followingconditions occur:

• The yellow diaphragm enters the red zone.

• The red piston locks in the visible position.

Test the Service IndicatorService indicators are important instruments.

• Check for ease of resetting. The service indicatorshould reset in less than three pushes.

• Check the movement of the yellow core when theengine is accelerated to the engine rated speed.The yellow core should latch approximately at thegreatest vacuum that is attained.

If the service indicator does not reset easily, or if theyellow core does not latch at the greatest vacuum,the service indicator should be replaced. If the newservice indicator will not reset, the hole for the serviceindicator may be plugged.

The service indicator may need to be replacedfrequently in environments that are severely dusty, ifnecessary. Replace the service indicator annuallyregardless of the operating conditions. Replace theservice indicator when the engine is overhauled, andwhenever major engine components are replaced.

Note: When a new service indicator is installed,excessive force may crack the top of the serviceindicator. Tighten the service indicator to a torqueof 2 N·m (18 lb in).

i01397717

Engine Air Precleaner - CleanSMCS Code: 1055-070

g00736588Illustration 62Typical precleaner

(1) Wing nut(2) Cover(3) Body

Remove wing nut (1) and cover (2). Check for anaccumulation of dirt and debris in body (3). Clean thebody, if necessary.

After cleaning the precleaner, install cover (2) andwing nut (1).

Note: When the engine is operated in dustyapplications, more frequent cleaning is required.

i02263740

Engine Crankcase Breather -CleanSMCS Code: 1317-070

NOTICEPerform this maintenance with the engine stopped.

If the crankcase breather is not maintained on aregular basis, the crankcase breather will becomeplugged. A plugged crankcase breather will causeexcessive crankcase pressure that may causecrankshaft seal leakage.

Page 22: CAT GENERATOR 3408c and 3412c Maintenence Manual

92 SEBU7843-01Maintenance SectionEngine Mounts - Inspect

g01136454Illustration 63Typical example(1) Hose clamp(2) Breather assembly(3) Retaining clamp(4) Seal

1. Loosen hose clamp (1) and remove the hose frombreather assembly (2).

2. Loosen retaining clamp (3). Remove the breatherassembly and seal (4).

3. Wash the breather element in solvent that is cleanand nonflammable. Allow the breather element todry before installation.

4. Install a breather element that is clean and dry.Install the seal, the breather assembly, and theclamp. Refer to the Specifications, SENR3130 inorder to locate the proper torques.

5. Install the hose. Install the hose clamp. Refer tothe Specifications, SENR3130 in order to locatethe proper torques.

i02139969

Engine Mounts - InspectSMCS Code: 1152-040

Inspect the engine mounts for deterioration and forproper bolt torque. Engine vibration can be causedby the following conditions:

• Improper mounting of the engine

• Deterioration of the engine mounts

Any engine mount that shows deterioration shouldbe replaced. Refer to the Specifications Manual,SENR3130, “Torque Specifications”. Refer to yourCaterpillar dealer for more information.

i00623423

Engine Oil Level - CheckSMCS Code: 1348-535-FLV

Hot oil and hot components can cause personalinjury. Do not allow hot oil or hot components tocontact the skin.

g00110310Illustration 64

(Y) “ADD” mark. (X) “FULL” mark.

NOTICEPerform this maintenance with the engine stopped.

1. Maintain the oil level between “ADD” mark (Y) and“FULL” mark (X) on oil level gauge (1). Do not fillthe crankcase above “FULL” mark (X).

NOTICEOperating your engine when the oil level is above the“FULL” mark could cause your crankshaft to dip intothe oil. The air bubbles created from the crankshaftdipping into the oil reduces the oil’s lubricating char-acteristics and could result in the loss of power.

2. Remove the oil filler cap and add oil, if necessary.Clean the oil filler cap. Install the oil filler cap.

i01935337

Engine Oil Sample - ObtainSMCS Code: 1000-008; 1348-554-SM;7542-554-OC, SM

In addition to a good preventive maintenanceprogram, Caterpillar recommends using S·O·S oilanalysis at regularly scheduled intervals in orderto monitor the condition of the engine and themaintenance requirements of the engine. S·O·S oilanalysis provides infrared analysis, which is requiredfor determining nitration and oxidation levels.

Page 23: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 93Maintenance Section

Engine Oil and Filter - Change

Obtain the Sample and the Analysis

Hot oil and hot components can cause personalinjury. Do not allow hot oil or hot components tocontact the skin.

Before you take the oil sample, complete the Label,PEEP5031 for identification of the sample. In orderto help obtain the most accurate analysis, providethe following information:

• Engine model

• Service hours on the engine

• The number of hours that have accumulated sincethe last oil change

• The amount of oil that has been added since thelast oil change

To ensure that the sample is representative of theoil in the crankcase, obtain a warm, well mixed oilsample.

To avoid contamination of the oil samples, the toolsand the supplies that are used for obtaining oilsamples must be clean.

Caterpillar recommends using the sampling valvein order to obtain oil samples. The quality and theconsistency of the samples are better when thesampling valve is used. The location of the samplingvalve allows oil that is flowing under pressure to beobtained during normal engine operation.

The 169-8373 Fluid Sampling Bottle isrecommended for use with the sampling valve. Thefluid sampling bottle includes the parts that areneeded for obtaining oil samples. Instructions arealso provided.

NOTICEAlways use a designated pump for oil sampling, anduse a separate designated pump for coolant sampling.Using the same pump for both types of samples maycontaminate the samples that are being drawn. Thiscontaminate may cause a false analysis and an incor-rect interpretation that could lead to concerns by bothdealers and customers.

If the engine is not equipped with a sampling valve,use the 1U-5718 Vacuum Pump. The pump isdesigned to accept sampling bottles. Disposabletubing must be attached to the pump for insertioninto the sump.

For instructions, see Special Publication, PEHP6001,“How To Take A Good Oil Sample”. Consult yourCaterpillar dealer for complete information andassistance in establishing an S·O·S program for yourengine.

i02107152

Engine Oil and Filter - ChangeSMCS Code: 1318-510; 1348-044

Hot oil and hot components can cause personalinjury. Do not allow hot oil or hot components tocontact the skin.

Do not drain the oil when the engine is cold. As the oilcools, suspended waste particles settle on the bottomof the oil pan. The waste particles are not removedwith the draining cold oil. Drain the crankcase withthe engine stopped. Drain the crankcase with theoil warm. This draining method allows the wasteparticles that are suspended in the oil to be drainedproperly.

Failure to follow this recommended procedure willcause the waste particles to be recirculated throughthe engine lubrication system with the new oil.

Drain the Engine OilAfter the engine has been run at the normal operatingtemperature, stop the engine. Use one of thefollowing methods to drain the engine crankcase oil:

• If the engine is equipped with a drain valve, turn thedrain valve knob counterclockwise in order to drainthe oil. After the oil has drained, turn the drain valveknob clockwise in order to close the drain valve.

• If the engine is not equipped with a drain valve,remove the oil drain plug in order to allow the oilto drain. If the engine is equipped with a shallowsump, remove the bottom oil drain plugs from bothends of the oil pan.

After the oil has drained, the oil drain plugs shouldbe cleaned and installed.

Page 24: CAT GENERATOR 3408c and 3412c Maintenence Manual

94 SEBU7843-01Maintenance SectionEngine Protection Devices - Calibrate

Replace the Oil Filter

NOTICECaterpillar oil filters are built to Caterpillar speci-fications. Use of an oil filter not recommended byCaterpillar could result in severe engine damage tothe engine bearings, crankshaft, etc., as a result ofthe larger waste particles from unfiltered oil enteringthe engine lubricating system. Only use oil filtersrecommended by Caterpillar.

1. Remove the oil filter with a 1U-8760 ChainWrench.

2. Cut the oil filter open with a 175-7546 Oil FilterCutter Gp. Break apart the pleats and inspect theoil filter for metal debris. An excessive amountof metal debris in the oil filter may indicate earlywear or a pending failure.

Use a magnet to differentiate between the ferrousmetals and the nonferrous metals that are found inthe oil filter element. Ferrous metals may indicatewear on the steel and cast iron parts of the engine.

Nonferrous metals may indicate wear on thealuminum parts, brass parts or bronze parts ofthe engine. Parts that may be affected includethe following items: main bearings, rod bearings,turbocharger bearings, and cylinder heads.

Due to normal wear and friction, it is notuncommon to find small amounts of debris in theoil filter. Consult your Caterpillar dealer in orderto arrange for a further analysis if an excessiveamount of debris is found in the oil filter.

g00103713Illustration 65Typical filter mounting base and filter gasket

3. Clean the sealing surface of the filter mountingbase. Ensure that all of the old oil filter gasket isremoved.

4. Apply clean engine oil to the new oil filter gasket.

NOTICEDo not fill the oil filters with oil before installing them.This oil would not be filtered and could be contaminat-ed. Contaminated oil can cause accelerated wear toengine components.

5. Install the oil filter. Tighten the oil filter until theoil filter gasket contacts the base. Tighten the oilfilter by hand according to the instructions that areshown on the oil filter. Do not overtighten the oilfilter.

Fill the Engine Crankcase1. Remove the oil filler cap. Refer to the Operationand Maintenance Manual, “Refill Capacities andRecommendations” for more information.

NOTICEIf equipped with an auxiliary oil filter system or a re-mote oil filter system, follow the OEM or filter manu-facturer’s recommendations. Under filling or overfillingthe crankcase with oil can cause engine damage.

NOTICETo prevent crankshaft bearing damage, crank the en-gine with the fuel OFF. This will fill the oil filters beforestarting the engine. Do not crank the engine for morethan 30 seconds.

2. Start the engine and run the engine at “LOWIDLE” for two minutes. Perform this procedure inorder to ensure that the lubrication system hasoil and that the oil filters are filled. Inspect the oilfilter for oil leaks.

3. Stop the engine and allow the oil to drain back tothe sump for a minimum of ten minutes.

4. Remove the oil level gauge in order to check theoil level. Maintain the oil level between the “ADD”and “FULL” marks on the oil level gauge.

i01046330

Engine Protection Devices -CalibrateSMCS Code: 7400-524

A calibration check of the engine protective deviceswill ensure that the alarms and shutoffs activate atthe setpoints.

To prevent damage to the engine, only authorizedservice personnel or your Caterpillar dealer shouldperform the tests.

Page 25: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 95Maintenance Section

Engine Valve Lash - Inspect/Adjust

• For the calibration of temperature contactors, seeSpecial Instruction, SEHS9827, “Calibration ofTemperature Contactors”.

• For the calibration of pressure contactors, seeSpecial Instruction, SEHS9828, “Calibration ofPressure Contactors”.

• For engines with the Caterpillar Marine MonitoringSystem, see Owner’s Manual, SEBU7134, “3600Diesel Marine Monitoring System”.

Consult your Caterpillar dealer or refer to the ServiceManual for more information.

i00869628

Engine Valve Lash -Inspect/AdjustSMCS Code: 1102-025

The initial valve lash adjustment on new engines,rebuilt engines, or remanufactured engines isrecommended at the first scheduled oil change. Theadjustment is necessary due to the initial wear ofthe valve train components and to the seating of thevalve train components.

This maintenance is recommended by Caterpillaras part of a lubrication and preventive maintenanceschedule in order to help provide maximum enginelife.

NOTICEOnly qualified service personnel should perform thismaintenance. Refer to the Service Manual or yourCaterpillar dealer for the complete valve lash adjust-ment procedure.

Operation of Caterpillar engines with improper valveadjustments can reduce engine efficiency. This re-duced efficiency could result in excessive fuel usageand/or shortened engine component life.

Ensure that the engine can not be started whilethis maintenance is being performed. To help pre-vent possible injury, do not use the starting motorto turn the flywheel.

Hot engine components can cause burns. Allowadditional time for the engine to cool before mea-suring/adjusting valve lash clearance.

Ensure that the engine is stopped before measuringthe valve lash. To obtain an accurate measurement,allow the valves to cool before this maintenance isperformed.

Refer to the Service Manual for more information.

i01597115

Engine Valve Rotators - InspectSMCS Code: 1109-040

When inspecting the valve rotators, protectiveglasses or face shield and protective clothingmust be worn, to help prevent being burned byhot oil or spray.

Engine valve rotators rotate the valves when theengine runs. This helps to prevent deposits frombuilding up on the valves and the valve seats.

Perform the following steps after the engine valvelash is set, but before the valve covers are installed:

1. Start the engine according to Operation andMaintenance Manual, “Engine Starting” (OperationSection) for the procedure.

2. Operate the engine at low idle.

3. Observe the top surface of each valve rotator.The valve rotators should turn slightly when thevalves close.

NOTICEA valve rotator which does not operate properly willaccelerate valve face wear and valve seat wear andshorten valve life. If a damaged rotator is not replaced,valve face guttering could result and cause pieces ofthe valve to fall into the cylinder. This can cause pistonand cylinder head damage.

If a valve fails to rotate, consult your Caterpillardealer.

Page 26: CAT GENERATOR 3408c and 3412c Maintenence Manual

96 SEBU7843-01Maintenance SectionFan Drive Bearing - Lubricate

i00175571

Fan Drive Bearing - LubricateSMCS Code: 1359-086-BD

g00123252Illustration 66Typical Fan Drive Bearing Grease Fitting

Lubricate the fan drive bearing grease fitting withBearing Lubricant Special Purpose Grease or theequivalent.

Inspect the fan drive pulley assembly. If the shaftis loose, an inspection of the internal componentsshould be performed. Refer to the Service Manual.

i01432350

Fuel Control Linkage -Check/LubricateSMCS Code: 1257-086; 1257-535

Check the fuel control linkage for proper operation. Ifnecessary, adjust the fuel control linkage. A variety oflinkages can be used. The type of linkage depends onthe type of installation. Therefore, refer to the OEM ofthe vessel for the specific type of fuel control linkage.

Some fuel control linkages require lubrication.Lubricate the grease fittings with 1P-0808Multipurpose Grease or the equivalent.

i00626014

Fuel Injection Nozzles -Test/ExchangeSMCS Code: 1254-013; 1254-081

Fuel leaked or spilled onto hot surfaces or electri-cal components can cause a fire.

NOTICEDo not allow dirt to enter the fuel system. Thoroughlyclean the area around a fuel system component thatwill be disconnected. Fit a suitable cover over discon-nected fuel system component.

Fuel injection nozzles are subject to tip wear. Tipwear is a result of fuel contamination. Tip wear cancause the following problems:

• Increased fuel consumption

• Black smoke

• Misfire

• Rough running

Fuel Injection nozzles should be cleaned, inspected,tested, and replaced, if necessary. Refer to SpecialInstruction, SEHS7292 for using the 8S-2245Injection Cleaning Tool Group. Consult yourCaterpillar dealer about cleaning the fuel injectionnozzle and testing the fuel injection nozzle.

NOTICENever wire brush or scrape a fuel injection nozzle.Wire brushing or scraping a fuel injection nozzle willdamage the finely machine orifice. Proper tools forcleaning and testing the fuel injection nozzles can beobtained from Caterpillar dealers.

The following items are symptoms of a malfunction ofthe fuel injection nozzle:

• Abnormal engine operation

• Smoke emission

• Engine knock

Each fuel injection nozzle must be isolated one ata time in order to determine the malfunctioning fuelinjection nozzle.

1. Start the engine.

2. Loosen each fuel line nut one at a time at the fuelinjection pump. A cloth or similar material must beused in order to prevent fuel from spraying on thehot exhaust components. Tighten each nut beforeloosening the next nut.

3. A defective fuel injection nozzle may be identifiedwhen a fuel line nut is loosened and the followingconditions are present:

• The exhaust smoke is partially eliminated or theexhaust smoke is completely eliminated.

Page 27: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 97Maintenance Section

Fuel Ratio Control - Inspect/Adjust

• Engine performance is not affected.

A fuel injection nozzle that is suspected of beingdefective should be removed. A new fuel injectionnozzle should be installed in the cylinder in orderto determine if the removed fuel injection nozzle isdefective.

Removal and Installation of theFuel Injection NozzlesFor the removal and the installation of fuel injectionnozzles, special tooling is required. Refer to theService Manual for more information. Consult yourCaterpillar dealer for assistance.

i00908934

Fuel Ratio Control -Inspect/AdjustSMCS Code: 1278-025; 1278-040

Slow engine response and low power may indicate aneed for adjustment or repair of the fuel ratio control.Refer to the Service Manual or your Caterpillar dealerfor the complete adjustment procedure on the fuelratio control.

i00891826

Fuel System - PrimeSMCS Code: 1258-548

Personal injury or death can result from a fire.

Fuel leaked or spilled onto hot surfaces or electri-cal components can cause a fire.

Clean up all leaked or spilled fuel. Do not smokewhile working on the fuel system.

Turn the disconnect switch OFF or disconnect thebattery when changing fuel filters.

Prime the fuel system in order to fill dry fuel filters.You must also prime the fuel system after any one ofthe following conditions exist:

• The fuel system has run dry.

• The engine has been in prolonged storage.

• The fuel filter has been cleaned.

• The fuel filter has been replaced.

Note: If the engine does not have a fuel primingpump, refer to Step 4.

1. Unlock the priming pump, and operate the primingpump until a resistance is felt. This procedurewill probably require a considerable amount ofpriming.

2. Push in the plunger, and hand tighten the plunger.

NOTICEDo not crank the engine for more than 30 seconds. Al-low the starter to cool for two minutes before crankingagain. Turbocharger damage can result if the enginerpm is not kept low until the oil gauge display verifiesthat the oil pressure is sufficient.

3. Crank the engine.

If the engine starts and the engine runs rough,run the engine at low idle. Continue running theengine until the engine runs smoothly.

NOTICEDuring periodic service, DO NOT remove the fuel filterplug that is in the fuel filter base in order to purge airfrom the fuel system. The periodic removal of the fuelfilter plug will result in increased wear on the threadsin the fuel filter base. This wear leads to fuel leakage.

4. Open the vent valve (if equipped) on the fuelinjection pump’s housing.

5. Operate the priming pump until the flow of fuelfrom the vent valve is continuous and the flow offuel is free of air bubbles.

If the engine does not have a fuel priming pump,crank the engine. Crank the engine until the fuelflows freely and until the fuel is free of air bubbles.

6. Close the vent valve. Then, push in the plunger.Hand tighten the plunger.

7. Crank the engine. If the engine starts and if theengine runs rough, run the engine at low idle.Continue running the engine until the engine runssmoothly.

Note: If the engine will not start, more priming isnecessary. If the engine continues to run rough, morepriming is necessary as well.

Page 28: CAT GENERATOR 3408c and 3412c Maintenence Manual

98 SEBU7843-01Maintenance SectionFuel System Primary Filter - Clean/Replace

NOTICEDo not let the tops of fuel nozzles turn when the fuelline nuts are loosened or tightened.

The nozzles will be damaged if the top of the nozzleturns in the body.

The engine will be damaged if a defective fuel injec-tion nozzle is used because the shape of fuel (spraypattern) that comes out of the nozzles will not be cor-rect.

g00290109Illustration 67

8. Loosen the fuel line nuts at the valve cover base.Loosen these line nuts one at a time.

9. Operate the priming pump until the flow of fuelfrom the fuel line is continuous and the flow of fuelis free of air bubbles.

10.Push in the plunger, and hand tighten the plunger.If the engine does not have a fuel priming pump,crank the engine.

11.Tighten each fuel line nut before you loosen thenext fuel line nut. Tighten the fuel line nuts to atorque of 40 ± 7 N·m (30 ± 5 lb ft).

Continue this procedure until all of the fuel lineshave been cleared of any air. Before you startthe engine, make sure that the fuel line nutsare properly tightened. Also make sure that thepriming is locked.

i00951418

Fuel System Primary Filter -Clean/ReplaceSMCS Code: 1260-070; 1260-510

Fuel leaked or spilled onto hot surfaces or elec-trical components can cause a fire. To help pre-vent possible injury, turn the start switch off whenchanging fuel filters or water separator elements.Clean up fuel spills immediately.

1. Stop the engine.

2. Turn the start switch to the “OFF” position.Disconnect the battery.

3. Shut off the fuel tank supply valve to the engine.

4. If the primary fuel filter is equipped with a drainvalve, open the drain valve in order to drain anyfuel from the filter case. Close the drain valve.

NOTICEUse a suitable container to catch any fuel that mightspill. Clean up any spilled fuel immediately.

g00485293Illustration 68(1) Bolt(2) Element(3) Case

5. Loosen the bolt (1) that is on the filter housing.Remove the filter case (3).

6. Remove the element (2) and wash the element inclean, nonflammable solvent.

Page 29: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 99Maintenance Section

Fuel System Secondary Filter - Replace

NOTICEDo not fill the fuel filters with fuel before installing them.The fuel would not be filtered and could be contami-nated. Contaminated fuel will cause accelerated wearto fuel system parts.

7. Install the element (2) and the filter case (3).Tighten the bolt (1) to a torque of 24 ± 4 N·m(18 ± 3 lb ft).

i01776046

Fuel System Secondary Filter -ReplaceSMCS Code: 1261-510-SE

Fuel leaked or spilled onto hot surfaces or elec-trical components can cause a fire. To help pre-vent possible injury, turn the start switch off whenchanging fuel filters or water separator elements.Clean up fuel spills immediately.

NOTICEDo not allow dirt to enter the fuel system. Thoroughlyclean the area around a fuel system component thatwill be disconnected. Fit a suitable cover over any dis-connected fuel system components.

NOTICEUse a suitable container to catch any fuel that mightspill. Clean up any spilled fuel immediately.

1. Stop the engine. Turn the ignition switch to theOFF position or disconnect the battery. Refer tothe Operation and Maintenance Manual, “Batteryor Battery Cable - Disconnect” topic (MaintenanceSection) for more information. Shut off the fuelsupply valve (if equipped).

2. It may be necessary to relieve residual fuelpressure from the fuel system before the fuelfilter is removed. Wait for one to five minutes untilthe fuel pressure has lowered. Use a suitablecontainer in order to catch any fuel that may spill.

3. Remove the used fuel filter and discard the usedfuel filter.

4. Clean the gasket sealing surface of the fuel filterbase. Ensure that all of the old gasket is removed.

5. Apply clean diesel fuel to the new fuel filter gasket.

NOTICEDo not fill the secondary fuel filter with fuel before in-stalling. The fuel would not be filtered and could becontaminated. Contaminated fuel will cause acceler-ated wear to fuel system parts.

NOTICEIn order to maximize fuel system life and prevent pre-mature wear out from abrasive particles in the fuel, atwo micron high efficiency fuel filter is required for allCaterpillar Electronic Unit Injectors. Caterpillar HighEfficiency Fuel Filters meet these requirements. Con-sult your Caterpillar dealer for the proper part num-bers.

6. Install the new fuel filter. Spin the fuel filter ontothe fuel filter base until the gasket contacts thebase. Use the rotation index marks on the filtersas a guide for proper tightening. Tighten the filteraccording to the instructions that are on the fuelfilter. Do not overtighten the filter.

7. Open the fuel supply valve. The engine will needto be purged of air. Refer to the Operation andMaintenance Manual, “Fuel System - Prime” topic(Maintenance Section) for more information.

i01877350

Fuel Tank Water and Sediment- DrainSMCS Code: 1273-543-M&S

NOTICECare must be taken to ensure that fluids are containedduring performance of inspection, maintenance, test-ing, adjusting and repair of the product. Be prepared tocollect the fluid with suitable containers before open-ing any compartment or disassembling any compo-nent containing fluids.

Refer to Special Publication, NENG2500, “CaterpillarTools and Shop Products Guide” for tools and suppliessuitable to collect and contain fluids on Caterpillarproducts.

Dispose of all fluids according to local regulations andmandates.

Page 30: CAT GENERATOR 3408c and 3412c Maintenence Manual

100 SEBU7843-01Maintenance SectionGenerator - Dry

Fuel TankFuel quality is critical to the performance and to theservice life of the engine. Water in the fuel can causeexcessive wear to the fuel system. Condensationoccurs during the heating and cooling of fuel. Thecondensation occurs as the fuel passes through thefuel system and the fuel returns to the fuel tank. Thiscauses water to accumulate in fuel tanks. Drainingthe fuel tank regularly and obtaining fuel from reliablesources can help to eliminate water in the fuel.

Drain the Water and the SedimentFuel tanks should contain some provision for drainingwater and draining sediment from the bottom of thefuel tanks.

Open the drain valve on the bottom of the fuel tankin order to drain the water and the sediment. Closethe drain valve.

Check the fuel daily. Drain the water and sedimentfrom the fuel tank after operating the engine or drainthe water and sediment from the fuel tank after thefuel tank has been filled. Allow five to ten minutesbefore performing this procedure.

Fill the fuel tank after operating the engine inorder to drive out moist air. This will help preventcondensation. Do not fill the tank to the top. Thefuel expands as the fuel gets warm. The tank mayoverflow.

Some fuel tanks use supply pipes that allow waterand sediment to settle below the end of the fuelsupply pipe. Some fuel tanks use supply lines thattake fuel directly from the bottom of the tank. Ifthe engine is equipped with this system, regularmaintenance of the fuel system filter is important.

Fuel Storage TanksDrain the water and the sediment from the fuelstorage tank during the following conditions:

• Weekly

• Oil change

• Refill of the tank

This will help prevent water or sediment from beingpumped from the storage tank into the engine fueltank.

If a bulk storage tank has been refilled or movedrecently, allow adequate time for the sediment tosettle before filling the engine fuel tank. Internalbaffles in the bulk storage tank will also help trapsediment. Filtering fuel that is pumped from thestorage tank helps to ensure the quality of the fuel.When possible, water separators should be used.

i01831525

Generator - DrySMCS Code: 4450-569

Personal injury or death can result from impropertroubleshooting and repair procedures.

The following troubleshooting and repair proce-dures should only be performed by qualified per-sonnel familiar with this equipment.

Refer to Safety Section, “Generator Isolating forMaintenance” for information regarding the procedureto safely isolate the generator.

If the insulation resistance values are less than therecommended values, one of the following dryingprocedures must be selected. This decision shouldbe based on the following factors:

• the size of the unit

• the location of the unit

• the equipment that is available

• the experience of personnel

Note: For more information on drying methods, referto Special Instruction, SEHS9124, “Cleaning andDrying of Electric Set Generators”.

Remove the voltage regulator. Cover all of the inletopenings. Cover all of the discharge holes. Providean opening at the top of the machine. This openingwill allow moisture to evaporate. Preferably, thisopening will be located at the fan end. Monitor thewinding temperatures. DO NOT APPLY HEAT TOORAPIDLY. Winding temperature should be raisedgradually at a rate of 10 °C (50 °F) per hour up to85 °C (185 °F). Measure insulation resistance at onehour intervals. Typically, the insulation resistancewill slowly drop while the temperature is rising. Theinsulation resistance will then start to increase at aslow rate until the insulation resistance reaches aconstant level .

Page 31: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 101Maintenance Section

Generator - Dry

The following methods can be used for drying agenerator:

• Self-circulating air method

• Oven method

• Controlled current method

Self-Circulating Air MethodRun the engine and disconnect the generator load.This will help circulate air. Operate the generatorspace heaters.

Oven MethodPlace the entire generator inside a forced air dryingoven for four hours at 65 °C (149 °F).

NOTICEUse a forced air type oven rather than a radiant typeoven.

Radiant type ovens can cause localized overheating.

Controlled Current MethodTable 17

Tools Needed

PartNumber

Description Qty

8T-0900 Clamp on ammeter (0 -1200 amperes)

1

External 12 Volt DC PowerSource

1

Rheostat 1

Switch 1

Heat can be used in order to dry the generatorwindings. This heat can be created by allowing acontrolled current to flow through the generator. Nohigh voltages are generated during the followingprocedure. Therefore, insulation breakdown will notoccur.

g00935477Illustration 69

Generator Wiring Diagram

(A) Clamp-on ammeter(B) Rotating field assembly(C) Rheostat(D) External 12 Volt DC Power Source(E) Switch(CR1-CR6) Diodes(CR7) Varistor(L1) Exciter field (stator)(L2) Exciter armature (rotor)(L3) Main field (rotor)(L4) Main armature (stator)

1. Obtain an external 12 Volt DC power source.

2. Refer to the above diagram. Disconnect “F1+”from the voltage regulator. Disconnect “F2-” fromthe voltage regulator.

3. Disconnect the generator load. Connect thegenerator output leads “T0”, “T1”, “T2”, and“T3” together. Install the clamp-on ammeter togenerator output lead “T1”.

Note: When the line current is measured onmultiple-lead units, measure the current in eachconductor for each phase. Add the currents together.

4. Refer to the above diagram. Connect rheostat (C).Adjust rheostat (C) to the maximum resistancevalue. Connect the external power source towires“F1+” and “F2-” with switch (E) in the openposition.

Page 32: CAT GENERATOR 3408c and 3412c Maintenence Manual

102 SEBU7843-01Maintenance SectionGenerator - Inspect

5. Start the generator set. Run the generator set atidle speed.

6. Monitor the phase current. Gradually increase theengine RPM. Increase the engine RPM until oneof the following conditions are met:

• The rated phase current is obtained.

• The full generator set speed is obtained.

7. If more phase current is still necessary, run thegenerator at idle speed and close switch (E).Slowly turn rheostat (C) until the rated phasecurrent is reached.

8. On an hourly basis, stop the drying procedure.Check the insulation resistance. Repeat the abovesteps until the insulation resistance is acceptable.

i01461264

Generator - InspectSMCS Code: 4450-040

Personal injury or death can result from impropertroubleshooting and repair procedures.

The following troubleshooting and repair proce-dures should only be performed by qualified per-sonnel familiar with this equipment.

Refer to Safety Section, “Generator Isolating forMaintenance” for information regarding the procedureto safely isolate the generator.

Proper maintenance of electrical equipment requiresperiodic visual examination of the generator andperiodic visual examination of the windings. Propermaintenance of electrical equipment also requiresappropriate electrical checks and appropriate thermalchecks. Insulation material should be examined forcracks. The insulation material should be examinedfor accumulations of dirt and dust. If there is aninsulation resistance value that is below normal, aconductive path may be present. This conductivepath may be made of one of the following materials:

• Carbon

• Salt

• Metal dust

• Dirt that is saturated with moisture

These contaminants will develop a conductive pathwhich may produce shorts. Cleaning is advisable ifheavy accumulations of dirt can be seen or if heavyaccumulations of dust can be seen. If excess dirt isthe cause of a restriction in the ventilation, cleaningis also advisable. Restricted ventilation will causeexcessive heating.

NOTICETo avoid the possibility of deterioration to the genera-tor windings, do not clean the generator unless thereis visual, electrical, or thermal evidence that dirt ispresent.

If harmful dirt accumulations are present, a varietyof cleaning techniques are available. The cleaningprocedure that is used may be determined by one ofthe items on the following list:

• The extent of the cleaning procedure that is beingattempted

• The type of enclosure of the generator

• The voltage rating of the generator

• The type of dirt that is being removed

Cleaning (Assembled Generators)Cleaning may be required at the point of installation.At this point, complete disassembly of the generatormay not be necessary or feasible. In this case,a vacuum cleaner should be used to pick up thefollowing items: dry dirt, dust, and carbon. This willprevent the spreading of these contaminants.

A small nonconductive tube may need to beconnected to the vacuum cleaner. This will allow thevacuum cleaner to clean the surfaces that are notexposed. After most of the dust has been removed,a small brush may be attached to the vacuum hosein order to loosen dirt that is more firmly attached tothe surface.

After the initial cleaning with a vacuum, compressedair may be used to remove the remaining dust anddirt. Compressed air that is used for cleaning shouldbe free of moisture and free of oil. Air pressureshould be a maximum of 210 kPa (30 psi) in order toprevent mechanical damage to the insulation. If theabove cleaning procedures are not effective, consulta Caterpillar dealer.

Page 33: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 103Maintenance Section

Generator Load - Check

Cleaning (DisassembledGenerators)An initial insulation resistance check should bemade on the generator in order to confirm electricalintegrity. A minimum reading of one megohm wouldbe expected with severely contaminated generators.A zero megohm reading may indicate an insulationbreakdown. An insulation breakdown requires morethan cleaning. An insulation breakdown requiresrepair.

A high pressure wash is normally an effective wayto clean windings. This includes windings that havebeen exposed to flooding or windings that have beencontaminated by salt. A solution of hot water anddetergent is used for this method of cleaning.

A high pressure wash sprays a high velocity fluidstream of this solution over the generator that isbeing cleaned. This detergent washing is followed bymultiple sprays of clean water. The clean water isused in order to remove the detergent or the cleanwater is used in order to dilute the detergent.

Allow the generator to dry at room temperature.Check the insulation resistance. The insulationresistance should now be normal. If the insulationresistance is not normal, repeat the procedure. Itmay be necessary to use solvents if the generatoris contaminated with oil or if the generator iscontaminated with grease.

Note: For more information on drying methods, referto Special Instructions, SEHS9124, “Cleaning andDrying of Electric Set Generators”.

i01228480

Generator Load - CheckSMCS Code: 4450-535-LA

During normal operation, monitor the power factorand monitor generator loading.

When a generator is installed or when a generatoris reconnected, ensure that the total current in anyone phase does not exceed the nameplate rating.Each phase should carry the same load. This allowsthe generator to work at the rated capacity. If onephase current exceeds the nameplate amperage,an electrical imbalance will occur. An electricalimbalance can result in an electrical overload and anelectrical imbalance can result in overheating .

The power factor can be referred to as the efficiencyof the load. This can be expressed as the ratio of kVAto actual kW. The power factor can be calculated bydividing kW by kVA. Power factor is expressed as adecimal. Power factor is used to mean the portionof current that is supplied to a system that is doinguseful work. The portion of the current that is notdoing useful work is absorbed in maintaining themagnetic field in motors. This current (reactive load)can be maintained without engine power.

Electric sets normally have a low idle setting thatis higher than industrial engines. Low idle will beapproximately 66% of the full speed that is achievedby 60 Hz units. This would be equal to 80% of the fullspeed that is achieved by 50 Hz units.

Some electric sets are equipped with Woodwardgovernors and some electric sets are equippedwith Caterpillar electronic governors. These electricsets have no low idle stop. On electric sets withmechanical governors and natural gas electric sets,the low idle is set at the factory. Adjustment of thelow idle on these machines should only be done bya Caterpillar dealer.

Note: Operating the electric set at low idle speed foran extended time will cause some voltage regulatorsto shut off. The electric set must be completely shutdown and the electric set must be restarted. Thiswill allow the voltage regulator to again produce anoutput.

Page 34: CAT GENERATOR 3408c and 3412c Maintenence Manual

104 SEBU7843-01Maintenance SectionGenerator Set - Test

i01593517

Generator Set - TestSMCS Code: 4450-081

Personal injury or death can result from high volt-age.

When power generation equipment must be in op-eration to make tests and/or adjustments, highvoltage and current are present.

Improper test equipment can fail and present ahigh voltage shock hazard to its user.

Make sure the testing equipment is designed forand correctly operated for high voltage and cur-rent tests being made.

When servicing or repairing electric power gener-ation equipment:

• Make sure the unit is off-line (disconnectedfrom utility and/or other generators powerservice), and either locked out or tagged DONOT OPERATE.

• Make sure the generator engine is stopped.

• Make sure all batteries are disconnected.

• Make sure all capacitors are discharged.

Table 18

Tools Needed

Part Number Part Quantity

6V-7070 DigitalMultimeter 1

12 VDC battery 1

PotentialTransformer 1

The generator set functional test is a simplified testthat can be performed in order to determine if thegenerator is functional. The generator set functionaltest should be performed on a generator set that isunder load.

The generator set functional test determines if thefollowing statements happen:

• A phase voltage is being generated.

• The phase voltages are balanced.

• The phase voltages change relative to enginespeed.

The generator set functional test consists of thefollowing steps:

1. Stop the generator. Connect the potentialtransformer’s high voltage winding to thegenerator terminals (T1) and (T2). Connectthe voltmeter to the low voltage winding. If twotransformers are available, connect the highvoltage winding of the second transformer to thegenerator terminals (T1) and (T3). Connect thesecondary terminals that correspond to generatorterminal (T2) of both transformers together.

2. Disconnect wires “E+” and “E-” from the voltageregulator. Disconnect the generator from the load.

3. Connect a 12 VDC automotive battery to wires“E+” and “E-”.

4. Measure the AC voltage across the low voltageterminals of the transformer that correspond to thefollowing generator terminals: “T1” and “T2”, “T2”and “T3”, and “T3” and “T1”. Record the voltages.

i02211917

Generator Set Vibration -InspectSMCS Code: 4450-040-VI

Check for vibration damage. Vibration may cause thefollowing problems:

• Loose fittings

• Loose belts

• Excessive noise

• Cracked insulation

The following areas are susceptible to vibrationdamage:

• Stator output leads

• Protective sleeving

• Insulation

• Exposed electrical connections

• Transformers

• Fuses

• Capacitors

Page 35: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 105Maintenance Section

Hoses and Clamps - Inspect/Replace

• Lightning arresters

When a generator set is installed a vibration plotshould be recorded in order to assist in diagnosingpotential problems. This vibration plot should beupdated yearly. The vibration plot should also beupdated when the generator set is moved. Refer toData Sheet, LEKQ4023, “Linear Vibration” for theallowable limits of vibration.

Contact the Caterpillar Dealer Service Tools groupfor information on ordering a vibration analyzer thatwill meet your needs.

i02121526

Hoses and Clamps -Inspect/ReplaceSMCS Code: 7554-040; 7554-510

Inspect all hoses for leaks that are caused by thefollowing conditions:

• Cracking

• Softness

• Loose clamps

Replace hoses that are cracked or soft. Tighten anyloose clamps.

NOTICEDo not bend or strike high pressure lines. Do not in-stall bent or damaged lines, tubes or hoses. Repairany loose or damaged fuel and oil lines, tubes andhoses. Leaks can cause fires. Inspect all lines, tubesand hoses carefully. Tighten all connections to the rec-ommended torque.

Check for the following conditions:

• End fittings that are damaged or leaking

• Outer covering that is chafed or cut

• Exposed wire that is used for reinforcement

• Outer covering that is ballooning locally

• Flexible part of the hose that is kinked or crushed

• Armoring that is embedded in the outer covering

A constant torque hose clamp can be used in placeof any standard hose clamp. Ensure that the constanttorque hose clamp is the same size as the standardclamp.

Due to extreme temperature changes, the hose willheat set. Heat setting causes hose clamps to loosen.This can result in leaks. A constant torque hoseclamp will help to prevent loose hose clamps.

Each installation application can be different. Thedifferences depend on the following factors:

• Type of hose

• Type of fitting material

• Anticipated expansion and contraction of the hose

• Anticipated expansion and contraction of thefittings

Replace the Hoses and the Clamps

Pressurized System: Hot coolant can cause seri-ous burns. To open the cooling system filler cap,stop the engine and wait until the cooling systemcomponents are cool. Loosen the cooling systempressure cap slowly in order to relieve the pres-sure.

1. Stop the engine. Allow the engine to cool.

2. Loosen the cooling system filler cap slowly inorder to relieve any pressure. Remove the coolingsystem filler cap.

Note: Drain the coolant into a suitable, cleancontainer. The coolant can be reused.

3. Drain the coolant from the cooling system to alevel that is below the hose that is being replaced.

4. Remove the hose clamps.

5. Disconnect the old hose.

6. Replace the old hose with a new hose.

7. Install the hose clamps with a torque wrench.

Note: Refer to the Specifications, SENR3130,“Torque Specifications” in order to locate the propertorques.

8. Refill the cooling system.

9. Clean the cooling system filler cap. Inspect thecooling system filler cap’s gaskets. Replacethe cooling system filler cap if the gaskets aredamaged. Install the cooling system filler cap.

Page 36: CAT GENERATOR 3408c and 3412c Maintenence Manual

106 SEBU7843-01Maintenance SectionMagnetic Pickups - Clean/Inspect

10.Start the engine. Inspect the cooling system forleaks.

i00906366

Magnetic Pickups -Clean/InspectSMCS Code: 1907-040; 7400-040; 7400-070

g00293335Illustration 70Typical example

(1) Magnetic pickup(2) Flywheel housing

g00293337Illustration 71

Typical magnetic pickup

1. Remove magnetic pickup (1) from flywheelhousing (2). Check the condition of the end of themagnetic pickup. Check for signs of wear andcontaminants.

2. Clean the metal shavings and other debris fromthe face of the magnet.

3. Install the magnetic pickup and adjust themagnetic pickup. Refer to the Service Manual forthe installation procedure.

i02018788

Overhaul ConsiderationsSMCS Code: 7595-043

Reduced hours of operation at full load will result in alower average power demand. A decreased averagepower demand should increase both the engineservice life and the overhaul interval.

The need for an overhaul is generally indicated byincreased fuel consumption and by reduced power.

The following factors are important when a decisionis being made on the proper time for an engineoverhaul:

• The need for preventive maintenance

• The quality of the fuel that is being used

• The operating conditions

• The results of the S·O·S analysis

Oil Consumption as an OverhaulIndicatorOil consumption, fuel consumption, and maintenanceinformation can be used to estimate the totaloperating cost for your Caterpillar engine. Oilconsumption can also be used to estimate therequired capacity of a makeup oil tank that is suitablefor the maintenance intervals.

Oil consumption is in proportion to the percentageof the rated engine load. As the percentage of theengine load is increased, the amount of oil that isconsumed per hour also increases.

The oil consumption rate (brake specific oilconsumption) is measured in grams per kW/h (lb perbhp). The brake specific oil consumption (BSOC)depends on the engine load. Consult your Caterpillardealer for assistance in determining the typical oilconsumption rate for your engine.

When an engine’s oil consumption has risen to threetimes the original oil consumption rate due to normalwear, an engine overhaul should be scheduled.There may be a corresponding increase in blowbyand a slight increase in fuel consumption.

Overhaul Options

Before Failure Overhaul

A planned overhaul before failure may be the bestvalue for the following reasons:

Page 37: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 107Maintenance Section

Overhaul Considerations

• Costly unplanned downtime can be avoided.

• Many original parts can be reused according to thestandards for reusable parts.

• The engine service life can be extended without therisk of a major catastrophe due to engine failure.

• The best cost/value relationship per hour ofextended life can be attained.

After Failure Overhaul

If a major engine failure occurs and the enginemust be removed, many options are available. Anoverhaul should be performed if the engine block orthe crankshaft needs to be repaired.

If the engine block is repairable and/or the crankshaftis repairable, the overhaul cost should be between 40percent and 50 percent of the cost of a new enginewith a similar exchange core.

This lower cost can be attributed to three aspects:

• Specially designed Caterpillar engine features

• Caterpillar dealer exchange components

• Caterpillar Inc. remanufactured exchangecomponents

Overhaul RecommendationTo minimize downtime, a scheduled engine overhaulby your Caterpillar dealer is recommended. This willprovide you with the best cost/value relationship.

Note: Overhaul programs vary according to theengine application and according to the dealer thatperforms the overhaul. Consult your Caterpillardealer for specific information about the availableoverhaul programs and about overhaul services forextending the engine life.

If an overhaul is performed without overhaul servicefrom your Caterpillar dealer, be aware of the followingmaintenance recommendations.

Unit Fuel Injector

Clean the fuel injector body and replace the O-rings.Replace the O-rings and the gasket on the injectorsleeve. Clean the area around the injector seatingin the injector sleeve. Refer to the Service Manualfor the complete procedure, or consult with yourCaterpillar dealer for assistance.

Rebuild or Exchange

Cylinder Head Assembly, Connecting Rods,Pistons, Cylinder Liners, Turbocharger, CylinderPacks, Oil Pump, and Fuel Transfer Pump

These components should be inspected according tothe instructions that are found in various Caterpillarreusability publications. The Special Publication,SEBF8029 lists the reusability publications that areneeded for inspecting the engine parts.

If the parts comply with the established inspectionspecifications that are expressed in the reusableparts guideline, the parts should be reused.

Parts that are not within the established inspectionspecifications should be dealt with in one of thefollowing manners:

• Salvaging

• Repairing

• Replacing

Using out-of-spec parts can result in the followingproblems:

• Unscheduled downtime

• Costly repairs

• Damage to other engine parts

• Reduced engine efficiency

• Increased fuel consumption

Reduced engine efficiency and increased fuelconsumption translates into higher operating costs.Therefore, Caterpillar Inc. recommends repairingout-of-spec parts or replacing out-of-spec parts.

Inspection and/or Replacement

Piston Rings, Crankshaft Bearings, ValveRotators, and Crankshaft Seals

The following components may not last until thesecond overhaul.

• Thrust bearings

• Main bearings

• Rod bearings

• Valve rotators

• Crankshaft seals

Page 38: CAT GENERATOR 3408c and 3412c Maintenence Manual

108 SEBU7843-01Maintenance SectionOverhaul Considerations

Caterpillar Inc. recommends the installation of newparts at each overhaul period.

Inspect these parts while the engine is disassembledfor an overhaul.

Inspect the crankshaft for any of the followingconditions:

• Deflection

• Damage to the journals

• Bearing material that has seized to the journals

Check the journal taper and the profile of thecrankshaft journals. Check these components byinterpreting the wear patterns on the followingcomponents:

• Rod bearing

• Main bearings

Note: If the crankshaft is removed for any reason,use the magnetic particle inspection process to checkfor cracks in the crankshaft.

Inspect the camshaft for damage to the journals andto the lobes.

Note: If the camshaft is removed for any reason, usethe magnetic particle inspection process to check forcracks in the camshaft.

Inspect the following components for signs of wear orfor signs of scuffing:

• Camshaft bearings

• Camshaft followers

Caterpillar Inc. recommends replacing the crankshaftvibration damper.

Oil Cooler Core and Aftercooler Core

During an overhaul, the removal of the oil coolercore and the aftercooler core is recommended. Theoil cooler core and the aftercooler core should becleaned and pressure tested.

NOTICEDo not use caustic cleaners to clean the core.

Caustic cleaners can attack the internal metals of thecore and cause leakage.

Note: Use this cleaning procedure to clean the oilcooler core and the aftercooler core.

1. Remove the oil cooler core and the aftercoolercore.

2. Remove any debris from the oil cooler core andthe aftercooler core. To remove debris from the oilcooler core, turn the oil cooler core onto one end.To remove debris from the aftercooler core, turnthe aftercooler core upside-down.

3. Flush the oil cooler core and the aftercooler coreinternally with cleaner in order to loosen foreignsubstances. This will also help to remove oil fromthe oil cooler core and the aftercooler core.

Note: The use of Hydrosolv Liquid Cleaners isrecommended. Table 19 lists the Hydrosolv LiquidCleaners that are available from your Caterpillardealer.

Table 19

Hydrosolv Liquid Cleaners(1)

PartNumber Description Size

1U-5490 Hydrosolv 4165 19 L (5 US gallon)

174-6854 Hydrosolv 100 19 L (5 US gallon)(1) Use a two to five percent concentration of the cleaner attemperatures up to 93°C (200°F). Refer to ApplicationGuide, NEHS0526 or consult your Caterpillar dealer for moreinformation.

4. Use steam to clean the oil cooler core and theaftercooler core. This removes any remainingresidue from the cleaner. Flush the fins of the oilcooler core and the aftercooler core. Remove anyother trapped debris.

5. Wash the oil cooler core and the aftercooler corewith hot, soapy water. Rinse the oil cooler core andthe aftercooler core thoroughly with clean water.

Personal injury can result from air pressure.

Personal injury can result without following prop-er procedure.When using pressure air, wear a pro-tective face shield and protective clothing.

Maximum air pressure at the nozzle must be lessthan 205 kPa (30 psi) for cleaning purposes.

6. Dry the oil cooler core and the aftercooler corewith compressed air. Direct the air in the reversedirection of the normal flow.

Page 39: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 109Maintenance Section

Radiator - Clean

7. Inspect the components in order to ensurecleanliness. The oil cooler core and the aftercoolercore should be pressure tested. Repair the oilcooler core and the aftercooler core, if necessary.Install the oil cooler core and the aftercooler core.

For more information about cleaning the cores,consult your Caterpillar dealer.

Obtain Coolant Analysis

The concentration of supplemental coolant additive(SCA) should be checked regularly with test kitsor with S·O·S Coolant Analysis (Level 1). Furthercoolant analysis is recommended when the engineis overhauled.

A coolant analysis can be conducted in order to verifythe condition of the water that is being used in thecooling system. A full water analysis can be obtainedby consulting your local water utility company oran agricultural agent. Private laboratories are alsoavailable for water analysis.

Caterpillar Inc. recommends an S·O·S CoolantAnalysis (Level 2).

S·O·S Coolant Analysis (Level 2)

An S·O·S Coolant Analysis (Level 2) is acomprehensive coolant analysis which completelyanalyzes the coolant and the effects on the coolingsystem. An S·O·S Coolant Analysis (Level 2) providesthe following information:

• Complete S·O·S Coolant Analysis (Level 2)

• Visual inspection of properties

• Identification of metal corrosion

• Identification of contaminants

• Identification of built up impurities (corrosion andscale)

S·O·S Coolant Analysis (Level 2) provides a report ofthe results of both the analysis and the maintenancerecommendations.

For more information about coolant analysis, consultyour Caterpillar dealer.

i01604510

Radiator - CleanSMCS Code: 1353-070

Note: Adjust the frequency of cleaning according tothe effects of the operating environment.

Inspect the radiator for these items: damaged fins,corrosion, dirt, grease, insects, leaves, oil, and otherdebris. Clean the radiator, if necessary.

Personal injury can result from air pressure.

Personal injury can result without following prop-er procedure.When using pressure air, wear a pro-tective face shield and protective clothing.

Maximum air pressure at the nozzle must be lessthan 205 kPa (30 psi) for cleaning purposes.

Pressurized air is the preferred method for removingloose debris. Direct the air in the opposite directionof the fan’s air flow. Hold the nozzle approximately6 mm (0.25 inch) away from the fins. Slowly move theair nozzle in a direction that is parallel with the tubes.This will remove debris that is between the tubes.

Pressurized water may also be used for cleaning.The maximum water pressure for cleaning purposesmust be less than 275 kPa (40 psi). Use pressurizedwater in order to soften mud. Clean the core fromboth sides.

Use a degreaser and steam for removal of oil andgrease. Clean both sides of the core. Wash the corewith detergent and hot water. Thoroughly rinse thecore with clean water.

After cleaning, start the engine and accelerate theengine to high idle rpm. This will help in the removalof debris and drying of the core. Stop the engine.Use a light bulb behind the core in order to inspectthe core for cleanliness. Repeat the cleaning, ifnecessary.

Inspect the fins for damage. Bent fins may be openedwith a “comb”. Inspect these items for good condition:welds, mounting brackets, air lines, connections,clamps, and seals. Make repairs, if necessary.

For more detailed information on cleaning andinspection, refer to Special Publication, SEBD0518,“Know Your Cooling System”.

Page 40: CAT GENERATOR 3408c and 3412c Maintenence Manual

110 SEBU7843-01Maintenance SectionSpace Heater - Check

i01754672

Space Heater - CheckSMCS Code: 4450-535-HTR

An SR4B generator is capable of operating in highhumidity conditions without problems. However,problems can occur when the generator is idle andthe surrounding air is warmer than the generator.Moisture can form on the windings that will result inpoor performance from the windings. Moisture canalso result in damage to the windings. Whenever thegenerator is not active, ensure that the space heatersare in operation.

Table 20

Tools Needed

Part Number Part Quantity

6V-7070 DigitalMultimeter 1

1. Stop the generator set.

2. Remove the panels in order to allow access tothe regulator and control terminal strips. Locateterminal strip “TS1”.

3. For 240 V systems, use the multimeter to measurethe voltage between terminal “H1” and terminal“H4”. If voltage is not present, disconnect thepower source to terminal “H1” and terminal “H4”,and check for 3 to 12 ohms resistance. If there isno resistance, check the generator service manualfor further information. For 120 V systems, usethe multimeter to measure the voltage betweenterminal “H1” and terminal “H2”. If voltage is notpresent, disconnect the power source to terminal“H1”, terminal “H2”, terminal “H3”, and terminal“H4”, and check for 3 to 12 ohms resistance. Ifthere is no resistance, check the generator servicemanual for further information.

i01943204

Standby GeneratorSet MaintenanceRecommendationsSMCS Code: 4450-041

A standby generator set may not need to be usedvery often. However, the generator set is usuallyneeded for operation in an emergency situation.Maintenance of the standby generator set is veryimportant for the following reasons:

• The generator set must always be in excellentoperating condition.

• The generator set must be ready to work underload at any time.

Establishing a Preventive Maintenance Program willprovide these benefits:

• Maximum availability of the standby generator set

• Longer service life for the generator set

• Minimum of expensive repairs

Your Caterpillar dealer can help you to establish aneffective Preventive Maintenance Program for yourgenerator set. Consult your Caterpillar dealer fordetails.

Maintenance and OperationProcedures

The high voltage that is produced by an operatinggenerator set can cause severe injury or death.Before performing any maintenance or repairs,ensure that the generator will not start.

Place the engine control switch in the “OFF” posi-tion. Attach “DO NOT OPERATE” tags to all start-ing controls. Disconnect the batteries or disablethe starting system. Lock out all switchgear andautomatic transfer switches that are associatedwith the generator.

The recommended maintenance for the generator setis listed in this Operation and Maintenance Manual,“Maintenance Interval Schedule (Standby GeneratorSets)” (Maintenance Section).

Maintenance and Repair

The maintenance that is recommended for EveryWeek can be performed by an authorized operator.The maintenance that is recommended for thesubsequent maintenance intervals must beperformed by an authorized service technician or byyour Caterpillar dealer.

Unless other instructions are provided, performmaintenance and repairs under the followingconditions:

• The engine is stopped.

• The starting system is disabled.

• The generator does not pose an electrical shockhazard.

Page 41: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 111Maintenance Section

Starting Motor - Inspect

Operation

To ensure proper operation, the generator set must beexercised regularly. For instructions on operating thegenerator set, see the Operation and MaintenanceManual for the generator set control panel.

For these operation procedures, follow theinstructions that are provided in this Operation andMaintenance Manual, “Operation Section”: startingthe engine, engine operation, and stopping theengine.

Record Keeping

Maintain a record in order to document these items:gauge readings, maintenance that is performed,problems, and repairs.

Space Heaters

Moisture causes damage to generators and otherelectrical equipment. Make every effort to keep thegenerator set as dry as possible.

Generators can operate without problems in humidenvironments. However, problems can occur whenthe generator is inactive. Moisture can condense onthe windings. This can result in poor performance.Also, damage to the windings can occur.

Use space heaters in order to help keep the windingsdry. When the generator is not active, ensure that thespace heaters are operating. When the generator isoperating, turn OFF the space heaters.

i00651416

Starting Motor - InspectSMCS Code: 1451-040; 1453-040

Caterpillar Inc. recommends a scheduled inspectionof the starting motor. If the starting motor fails, theengine may not start in an emergency situation.

Check the starting motor for proper operation. Checkthe electrical connections and clean the electricalconnections. Refer to the Service Manual for moreinformation on the checking procedure and forspecifications or consult your Caterpillar dealer forassistance.

i01539769

Turbocharger - InspectSMCS Code: 1052-040

Periodic inspection and cleaning is recommendedfor the turbocharger compressor housing (inlet side).Any fumes from the crankcase are filtered throughthe air inlet system. Therefore, by-products from oiland from combustion can collect in the turbochargercompressor housing. Over time, this buildup cancontribute to loss of engine power, increased blacksmoke and overall loss of engine efficiency.

If the turbocharger fails during engine operation,damage to the turbocharger compressor wheeland/or to the engine may occur. Damage to theturbocharger compressor wheel can cause additionaldamage to the pistons, the valves, and the cylinderhead.

NOTICETurbocharger bearing failures can cause large quan-tities of oil to enter the air inlet and exhaust systems.Loss of engine lubricant can result in serious enginedamage.

Minor leakage of a turbocharger housing under ex-tended low idle operation should not cause problemsas long as a turbocharger bearing failure has not oc-curred.

When a turbocharger bearing failure is accompaniedby a significant engine performance loss (exhaustsmoke or engine rpm up at no load), do not continueengine operation until the turbocharger is repaired orreplaced.

An inspection of the turbocharger can minimizeunscheduled downtime. An inspection of theturbocharger can also reduce the chance for potentialdamage to other engine parts.

Note: Turbocharger components require precisionclearances. The turbocharger cartridge mustbe balanced due to high rpm. Severe ServiceApplications can accelerate component wear.Severe Service Applications require more frequentinspections of the cartridge.

Removal and InstallationFor options regarding the removal, installation, repairand replacement, consult your Caterpillar dealer.Refer to the Service Manual for this engine for theprocedure and specifications.

Page 42: CAT GENERATOR 3408c and 3412c Maintenence Manual

112 SEBU7843-01Maintenance SectionWalk-Around Inspection

Cleaning and Inspecting1. Remove the exhaust outlet piping and removethe air inlet piping from the turbocharger. Visuallyinspect the piping for the presence of oil. Cleanthe interior of the pipes in order to prevent dirtfrom entering during reassembly.

2. Turn the compressor wheel and the turbine wheelby hand. The assembly should turn freely. Inspectthe compressor wheel and the turbine wheel forcontact with the turbocharger housing. Thereshould not be any visible signs of contact betweenthe turbine wheel or compressor wheel and theturbocharger housing. If there is any indication ofcontact between the rotating turbine wheel or thecompressor wheel and the turbocharger housing,the turbocharger must be reconditioned.

3. Check the compressor wheel for cleanliness.If only the blade side of the wheel is dirty, dirtand/or moisture is passing through the air filteringsystem. If oil is found only on the back side of thewheel, there is a possibility of a failed turbochargeroil seal.

The presence of oil may be the result of extendedengine operation at low idle. The presence of oilmay also be the result of a restriction of the linefor the inlet air (plugged air filters), which causesthe turbocharger to slobber.

4. Use a dial indicator to check the end clearanceon the shaft. If the measured end play is greaterthan the Service Manual specifications, theturbocharger should be repaired or replaced.An end play measurement that is less than theminimum Service Manual specifications couldindicate carbon buildup on the turbine wheel. Theturbocharger should be disassembled for cleaningand for inspection if the measured end play is lessthan the minimum Service Manual specifications.

5. Inspect the bore of the turbine housing forcorrosion.

6. Clean the turbocharger housing with standardshop solvents and a soft bristle brush.

7. Fasten the air inlet piping and the exhaust outletpiping to the turbocharger housing.

i01972472

Walk-Around InspectionSMCS Code: 1000-040

Inspect the Engine for Leaks andfor Loose ConnectionsA walk-around inspection should only take a fewminutes. When the time is taken to perform thesechecks, costly repairs and accidents can be avoided.

For maximum engine service life, make a thoroughinspection of the engine compartment before startingthe engine. Look for items such as oil leaks or coolantleaks, loose bolts, worn belts, loose connections andtrash buildup. Make repairs, as needed:

• The guards must be in the proper place. Repairdamaged guards or replace missing guards.

• Wipe all caps and plugs before the engine isserviced in order to reduce the chance of systemcontamination.

NOTICEFor any type of leak (coolant, lube, or fuel) clean up thefluid. If leaking is observed, find the source and correctthe leak. If leaking is suspected, check the fluid levelsmore often than recommended until the leak is foundor fixed, or until the suspicion of a leak is proved to beunwarranted.

NOTICEAccumulated grease and/or oil on an engine or deck isa fire hazard. Remove this debris with steam cleaningor high pressure water.

• Ensure that cooling lines are properly clamped.Check for leaks. Check the condition of all pipes.

• Inspect the water pump for coolant leaks.

Note: The water pump seal is lubricated by coolantin the cooling system. It is normal for a small amountof leakage to occur as the engine cools down andthe parts contract.

Excessive coolant leakage may indicate the needto replace the water pump seal. For the removal ofwater pump and the installation of water pump and/orseals, refer to the Service Manual for the engine orconsult your Caterpillar dealer.

• Inspect the lubrication system for leaks at the frontcrankshaft seal, the rear crankshaft seal, the oilpan, the oil filters and the valve cover.

Page 43: CAT GENERATOR 3408c and 3412c Maintenence Manual

SEBU7843-01 113Maintenance SectionWater Pump - Inspect

• Inspect the fuel system for leaks. Look for loosefuel line clamps.

• Inspect the piping for the air inlet system and theelbows for cracks and for loose clamps.

• Inspect the alternator belt and the accessory drivebelts for cracks, breaks or other damage.

Belts for multiple groove pulleys must be replaced asmatched sets. If only one belt is replaced, the belt willcarry more load than the belts that are not replaced.The older belts are stretched. The additional load onthe new belt could cause the belt to break.

• Drain the water and the sediment from fuel tankson a daily basis in order to ensure that only cleanfuel enters the fuel system.

• Inspect the wiring and the wiring harnesses forloose connections and for worn wires or frayedwires.

• Inspect the ground strap for a good connection andfor good condition.

• Inspect the engine-to-frame ground strap for agood connection and for good condition.

• Disconnect any battery chargers that are notprotected against the current drain of the startingmotor. Check the condition and the electrolyte levelof the batteries, unless the engine is equipped witha maintenance free battery.

• Check the condition of the gauges. Replace anygauges which are cracked or replace any gaugesthat can not be calibrated.

Inspect the InsulationA visual inspection should be initially directed atthe areas that are most prone to damage anddeterioration. The most prone areas to damage anddeterioration are listed below:

• Ground Insulation. Ground insulation is insulationthat is intended to isolate components that arecarrying current from components that are notcarrying current.

• Support Insulation. Support insulation isusually made from one of the following items:a compressed lamination of fibrous materials,polyester, or felt pads that have been impregnatedwith various types of bonding agents.

There are many different types of damage that canoccur in these areas. Several of the different types ofdamage are listed below:

Thermal Aging – Thermal aging can cause thedegradation of insulation or the deterioration ofinsulation. An examination of the coils may revealthat the insulation has expanded into the ventilationducts. This is the result of a loss of bond whichwill cause the insulation material to separate. Theinsulation material could also separate from theconductors on the windings.

Abrasion – The surfaces of coils and the surfacesof connectors may be damaged by abrasion. Thesesurfaces may also be damaged by contaminationfrom other sources. An example of these sourceswould be chemicals or abrasive substances.

Cracking – Cracking of insulation may result frommechanical stress. The structure that is used to bracethe stator winding will become loose if the problemis not corrected. Further mechanical damage orelectrical damage may also result.

Erosion – Erosion can be caused when foreignsubstances rub against the surfaces of the insulation.

i01057943

Water Pump - InspectSMCS Code: 1361-040; 1361

A failed water pump might cause severe engineoverheating problems that could result in the followingconditions:

• Cracks in the cylinder head

• A piston seizure

• Other potential damage to the engine

Visually inspect the water pump for leaks. If anyleaking is observed, replace the water pump sealor the water pump assembly. Refer to the ServiceManual for the disassembly and assembly procedure.

Note: Refer to the Service Manual or consult yourCaterpillar dealer if any repair is needed or anyreplacement is needed.