CASEMENT WINDOWS - loewencentre.com · Casement Windows A3 PRODUCT FEATURES STYLES: Traditional,...
Transcript of CASEMENT WINDOWS - loewencentre.com · Casement Windows A3 PRODUCT FEATURES STYLES: Traditional,...
A3 Product FeaturesA4 SpecificationsA5 A7 Parts Identification
A5 Casement WindowA6 Push Out Casement Window – Dual GlazedA7 French Casement Window
A8 A39 Product Elevations
A8 A27 Traditional Casement Windows
A8 15 3/4" (400 mm) & 19 11/16" (500 mm) CombinationsA10 23 5/8" (600 mm) & 27 9/16" (700 mm) CombinationsA12 29 1/2" (750 mm) & 31 1/2" (800 mm) CombinationsA14 35 7/16" (900 mm) CombinationsA16 15 3/4" (400 mm) to 27 9/16" (700 mm) Three Wide
Casement CombinationsA18 29 1/2" (750 mm) to 35 7/16" (900 mm) Three Wide
Casement CombinationsA20 Casement Combinations with 23 5/8" (600 mm) FlankersA21 Fixed CasementA27 French Casement
A28 A36 Traditional Camber Top Casement Window
A28 Camber Top Casement Standard RadiusA29 15 3/4" (400 mm) & 19 11/16" (500 mm) CombinationsA31 23 5/8" (600 mm) & 27 9/16" (700 mm) CombinationsA33 29 1/2" (750 mm) & 31 1/2" (800 mm) CombinationsA35 35 7/16" (900 mm) Combinations
A37 Traditional Half Round Casement Window
A37 23 5/8" (600 mm) & 35 7/16" (900 mm) Combinations
A38 A39 Traditional Quarter Round Casement Window
A38 19 11/16" (500 mm) CombinationsA39 23 5/8" (600 mm) & 27 9/16" (700 mm) Combinations
A40 A47 Product Details
A40 Casement Window/Wall ConnectionA41 Casement WindowA42 Push Out Casement WindowA43 Fixed Casement WindowA44 Mission Casement WindowA45 French Casement WindowA46 Push Out French Casement WindowA47 Radius Top Casement Window
A48 A51 Performance RatingsA52 A65 Light and Vent ScheduleA66 A67 Push Out Casement Window – Egress Opening ScheduleA68 A79 Guide Specifications
Casement windows are available in StormForce™. See Section K for more detailed information.
CASEMENT WINDOWS
A C
ase
me
nt
Win
do
ws
Can
ada
and
U.S
.A.
1.8
00
.56
3.9
36
7 /
In
tern
atio
nal
20
4.3
26
.64
46
CASEMENT WINDOWS
Douglas Fir Fixed Casements with Simulated Divided Lites
Casement Mission® Casement Push Out CasementFrench Chateau Casement(Camber Top)
Loewen makes four styles of Casement windows — Traditional, Mission®, French Chateauand Push Out.
A C
ase
me
nt
Win
do
ws
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A3
PRODUCT FEATURES
STYLES:
Traditional, Mission®, French Chateau and PushOut models. Quarter Round, Full Radius andCamber Top options.
STANDARD FEATURES
• Natural, clear Douglas Fir interior (no visiblefinger joints)
• Frame construction designed for 4 9/16" (116 mm) jamb
• Low E2 insulated glazing with 1/2" (12 mm)airspace
• Roto gear operator and concealed sash locks available in bronze, sandstone, linen and black
• Extruded aluminum cladding in nine standardcolors, primed wood or clear Fir exterior
• Santoprene™ weatherstrip system
• Insect screens available in bronze, sandstone,linen and black
HARDWARE:
Hardware and hardware finishes are dependenton hardware choices.
GLAZING:
Heat-Smart® 1, 2 and 3, Tranquility®, StormForce™ DP, IP, MP. StormForce™ DP, IP,MP not available for Push Out products.
SIMULATED DIVIDED LITES (SDL) ANDGRILLES:
SDL — 3/4" (19 mm), 1 1/8" (29 mm), 2" (50 mm), Removable Grilles.
BRICKMOULD:
2" (50 mm), 3 1/2" (89 mm) and 5 1/2" (140mm) wood. 2" (50 mm) and 3 1/2" (89 mm)metal.
METAL CLAD COLOR SPECTRUM:
Nine Standard Palette and 27 optionalArchitectural Palette colors. Available inCyprium Collection (see Section L page 23).
LEGEND: � — STANDARD
� — OPTIONAL
Hardware StylesFolding Crank Handle � � �
Push Out Handle �
Concealed Lock � � �
Electric Operator � �
Finish OptionsLinen � � � �
Sandstone � � � �
Bronze � � � �
Black � � � �
Oil Rubbed Bronze � � � �
Antique Brass � � � �
Bright Brass � � � �
Brushed Chrome � � � �
Satin Nickel � � � �
Rustic Bronze � � � �
Traditional Mission® French Push OutCasement Casement Casement Casement
VariablesFunction:Use for Egress � � � �
Available with Screen � � � � 2
Concealed Hardware � � �
Durability:Low Maintenance
� 1 � 1 � 1 � 1
Metal Clad ExteriorClear Douglas Fir
� � � �Exterior FinishClear Mahogany
� � � �Exterior FinishPrimed Exterior Finish � � � �
Performance:Heat-Smart® Plus 1 � � � �
Heat-Smart® Plus 2, 3 3 � � �
Tranquility® � � �
StormForce™ � �
Appearance:SDL � � � �
Traditional Mission® French Push OutCasement Casement Casement Casement
1 – Nine standard metal clad colors, 27 optional
2 – Swinging
3 – Some size restrictions apply
Specifications and technical information are subject to change without notice. Metric and Imperial measurements are converted accurately,however in some cases industry conventions cause a 1 mm variance. (Example: 3/4" is shown as 20 mm for all glass measurements as this isthe industry standard.)
All standard window
configurations
are represented
in this Loewen
Architectural Catalog.
Numerous custom
opportunities exist —
please contact your
Authorized
Loewen Dealer.
For a more in-depth, comprehensive
review of Product Features, please refer
to the Miscellaneous section.
Visit the Loewen Photo Gallery online at
www.loewen.com/home.nsf/info/gallery
for a large collection of Loewen product
and elevation photography.
B2
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A4
SPECIFICATIONS
STANDARDS
Units have been tested by an independent laboratory for air and water infiltration and thermal performance requirements.
FRAME AND SASH
Manufactured from Coastal Douglas Fir kiln-dried lumber with frame constructiondesigned for 4 9/16" (116 mm) jamb. All exteriorcomponents are factory primed; minor scratchesor abrasions are not considered defects.
ALTERNATE SPECIES
The entire Loewen product line is also availablein optional Mahogany (Swietenia macrophylla) oroptional FSC chain of custody certified DouglasFir (SW-COC-1739).
PRESERVATIVE TREATED
All wood parts are dipped in approved preservative.
GLAZING
A wood stop combined with glazing materialsensures a positive seal.
INSULATING GLASS
Double or triple glass configurations with 1/2" (12 mm) airspace.
HEAT-SMART® Plus Systems 1, 2 and 3
Heat-Smart® best describes the benefits of theproduct that incorporates Low E2 coating andargon gas. Heat-Smart® systems help reduceheating and cooling costs, providing superiorenergy efficiency.
SIMULATED DIVIDED LITES (SDL) AND GRILLES
Standard SDL come without airspace grilles.Optional airspace grilles available. Grille barsare permanently applied to the interior andexterior.
Loewen natural clear wood grilles install from the inside of the house and are removable for cleaning.
Note: Optional GrillesNatural wood grilles will be supplied unless otherwise specified.
METAL CLADDING
Heavy duty extruded aluminum exterior metalcladding is available in nine Standard Paletteand 27 optional Architectural Palette colors.Interior of window remains a natural wood finishas a standard. Metal clad units are suppliedready-to-install complete with nailing flange.
HARDWARE
Standard Casement sash opens out to 90degrees for ease of cleaning. The roto gearoperator will hold the sash at any position in its operating radius. The sash is supported by concealed heavy-duty hinges. All steel components have Truth E-GardTM coating forsuperior corrosion protection.
HARDWARE OPTION
Operator and sash locks are standard in bronze,linen, sandstone or black. Optional finishes areavailable at an additional charge. Casementunits available with a fold-away handle.
DOUBLE WEATHERSTRIP
The combination of a flexible Santoprene™
bubble and a flexible Santoprene™ bubble with fin weatherstrip complete with rigid slip ribsensures maximum energy efficiency.
SCREEN
Screens have a bronze, linen, sandstone or blackaluminum frame, screened with anti-glarefiberglass cloth.
EGRESS
Sizes noted in elevation drawings meet nationalegress codes for fire escape. Canada and U.S.A. are marked separately. Consult local buildingcodes for confirmation of size requirements foryour area. All calculations are done with doubleinsulated sash and standard hardware. Specialegress hardware is available for Casement windows that enables some sizes to meet egress codes, eliminating the need to go to the next larger size window.
B3
3
18
17
NO. DESCRIPTION
1 COMPRESSION WEATHERSTRIP (FRAME)2 HEAD JAMB3 HEAD/SILL METAL CLADDING4 SIDE METAL CLADDING5 SIDE JAMB MOULDING6 SASH LOCK7 HEAD JAMB MOULDING8 KEEPER9 SASH10 GLAZING STOP11 SEALED UNIT12 SUPPORT ARM13 SASH ARM14 MULTI POINT MIRAGE LOCK SYSTEM15 ROTO GEAR OPERATOR16 SILL COVER17 SILL18 HINGE TRACK19 STUD BRACKET20 NAILING FLANGE21 SASH METAL CLADDING22 SASH WEATHERSTRIP23 GLAZING TAPE24 OPERATOR TRACK25 SILL BLOCK 26 GROMMET27 SCREEN28 ESCUTCHEON PLATE29 SPACER BAR 30 SIDE JAMB31 JAMB EXTENSION
6
20
5 4
30
8
26
28
27
16
15
14
10
29
22 12
24
3
1
2
7
13
12
31
23
21
19
25
13
11
Note: • This drawing is not to scale. For parts identification only.
9
9
CASEMENT WINDOW
PARTS IDENTIFICATION
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A5
CSMT.3D.001.1.2005CAD DOWNLOAD: www.loewen.com/architect
B4
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A6
Note: • This drawing is not to scale. For parts identification only.
NO. DESCRIPTION
1 COMPRESSION WEATHERSTRIP 2 HEAD JAMB3 HEAD METAL CLADDING4 SIDE METAL CLADDING5 JAMB MOULDING6 SASH HANDLE7 JAMB EXTENSION8 SCREEN HANDLE9 SASH10 SCREEN HINGE11 GLAZING STOP12 SEALED UNIT13 SASH WEATHERSTRIP14 4 BAR FRICTION HINGE DS/DSE SERIES15 SCREEN FRAME RAIL 16 SCREEN FRAME STILE17 MAGNET COUNTERPLATE18 SNUBBER19 SCREEN CLOTH20 NAILING FLANGE21 SILL22 SIDE JAMB23 STRIKE24 RAIL CLADDING25 GLAZING TAPE
19 17
18
21
16
15 14
23
25
3
4
5
5
2
1
6
7
8
9
13
10
11
12
24
22
20
PUSH OUT CASEMENT WINDOW - DUAL GLAZED
PARTS IDENTIFICATION
CAD DOWNLOAD: www.loewen.com/architectCSMT.3D.003.1.2005
B5
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A7
Note: • This drawing is not to scale. For parts identification only.
NO. DESCRIPTION
1 COMPRESSION WEATHERSTRIP (FRAME)2 HEAD JAMB3 HEAD METAL CLADDING4 SIDE METAL CLADDING5 JAMB MOULDING6 SASH LOCK HANDLE7 JAMB EXTENSION8 TWO-PIECE CONNECTOR9 PASSIVE SASH10 ACTIVE SASH11 GLAZING STOP12 SEALED UNIT13 STUD BRACKET14 CRANK HANDLE15 OPERATOR COVER16 ROTO GEAR OPERATOR17 SILL COVER18 SILL19 NAILING FLANGE20 INTERIOR SASH NOSING21 SIDE JAMB22 SASH ARM23 HINGE TRACK24 ROLLER PLATE25 MULTI POINT HARDWARE26 SASH WEATHERSTRIP27 SILL BLOCK28 GROMMET29 SCREEN
18
17
26
28
27
16 15
14
29
22
24
3
4
1
6
5
2
7
8
20
9
13
10
11
12
23
21
19
25
FRENCH CASEMENT WINDOW
PARTS IDENTIFICATION
CAD DOWNLOAD: www.loewen.com/architect CSMT.3D.002.1.2005
Camber Top option shown.
B6
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.007.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.mm
in.
mm
in.
mmVisible
Glass
GlassSize
419
400
15 3/4
16 1/2
247
273
10 3/4
9 3/4
819
800
31 1/2
32 1/4
247
273
10 3/4
9 3/4
819
800
31 1/2
32 1/4
247
273
10 3/4
9 3/4
519
500
19 11/16
20 7/16
347
373
14 11/16
13 11/16
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
1019
1000
39 3/8
40 1/8
24 3
/8
619
600
23 5
/8
17 3
/8
442
468
18 7
/16
CA1 0406 L CA2 0806 LR CA2 0806 LF CA1 0506 L CA2 1006 LR CA2 1006 LF
719
28 5
/16
700
27 9
/16
542
21 5
/16
568
22 3
/8
CA1 0407 L CA2 0807 LR CA2 0807 LF CA1 0507 L CA2 1007 LR CA2 1007 LF
769
30 1
/4
750
29 1
/2
592
23 5
/16
618
24 5
/16
CA1 0475 L CA2 0875 LR CA2 0875 LF CA1 0575 L CA2 1075 LR CA2 1075 LF
819
32 1
/4
800
31 1
/2
642
25 1
/4
668
26 5
/16
CA1 0408 L CA2 0808 LR CA2 0808 LF CA1 0508 L CA2 1008 LR CA2 1008 LF
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
CA1 0409 L CA2 0809 LR CA2 0809 LF CA1 0509 L CA2 1009 LR CA2 1009 LF
40 1
/8
1019
1000
39 3
/8
33 1
/8
842
868
34 3
/16
CA1 0410 L CA2 0810 LR CA2 0810 LF CA1 0510 L CA2 1010 LR CA2 1010 LF
48 1219
47 1
/4
1200 41 1042
42 1
/16
1068
CA1 0412 L CA2 0812 LR CA2 0812 LF CA1 0512 L CA2 1012 LR CA2 1012 LF
347
373
14 11/16
13 11/16
15 3/4" (400 MM) COMBINATIONS 19 11/16" (500 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A8
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.008.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
419
400
15 3/4
16 1/2
247
273
10 3/4
9 3/4
819
800
31 1/2
32 1/4
247
273
10 3/4
9 3/4
819
800
31 1/2
32 1/4
247
273
10 3/4
9 3/4
519
500
19 11/16
20 7/16
347
373
14 11/16
13 11/16
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
49 1
5/16
CA1 0414 L CA2 0814 LR CA2 0814 LF CA1 0514 L CA2 1014 LR CA2 1014 LF
1519
59 1
3/16
1500
59 1
/16
1342
52 1
3/16
1368
53 7
/8
CA1 0415 L CA2 0815 LR CA2 0815 LF CA1 0515 L CA2 1015 LR CA2 1015 LF
1619
63 3
/4
160063 1442
56 3
/4
1468
57 1
3/16
CA1 0416 L CA2 0816 LR CA2 0816 LF CA1 0516 L CA2 1016 LR CA2 1016 LF
71 5
/8
1819
1800
70 7
/8
64 5
/8
1642
1668
65 1
1/16
CA1 0418 L CA2 0818 LR CA2 0818 LF CA1 0518 L CA2 1018 LR CA2 1018 LF
83 7
/16
2119
82 1
1/16
2100
76 7
/16
1942
77 1
/2
1968
CA1 0421 L CA2 0821 LR CA2 0821 LF CA1 0521 L CA2 1021 LR CA2 1021 LF
15 3/4" (400 MM) COMBINATIONS 19 11/16" (500 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A9
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.009.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
619
600
23 5/8
24 3/8
447
473
18 5/8
17 5/8
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
719
700
27 9/16
28 5/16
547
573
22 9/16
21 9/16
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
48 1219
47 1
/4
1200
CA1 0612 L CA2 1212 LR CA2 1212 LF CA1 0712 L CA2 1412 LR CA2 1412 LF
41 1042
42 1
/16
1068
40 1
/8
1019
1000
39 3
/8
CA1 0610 L CA2 1210 LR CA2 1210 LF CA1 0710 L CA2 1410 LR CA2 1410 LF
33 1
/8
842
868
34 3
/16
819
32 1
/4
800
31 1
/2
CA1 0608 L CA2 1208 LR CA2 1208 LF CA1 0708 L CA2 1408 LR CA2 1408 LF
642
25 1
/4
668
26 5
/16
719
28 5
/16
700
27 9
/16
CA1 0607 L CA2 1207 LR CA2 1207 LF CA1 0707 L CA2 1407 LR CA2 1407 LF
542
21 5
/16
568
22 3
/8
24 3
/8
619
600
23 5
/8
CA1 0606 L CA2 1206 LR CA2 1206 LF CA1 0706 L CA2 1406 LR CA2 1406 LF
17 3
/8
442
468
18 7
/16
769
30 1
/4
750
29 1
/2
CA1 0675 L CA2 1275 LR CA2 1275 LF CA1 0775 L CA2 1475 LR CA2 1475 LF
592
23 5
/16
618
24 5
/16
36 3
/16
919
900
35 7
/16
CA1 0609 L CA2 1209 LR CA2 1209 LF CA1 0709 L CA2 1409 LR CA2 1409 LF
29 3
/16
742
768
30 1
/4
23 5/8" (600 MM) COMBINATIONS 27 9/16" (700 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A10
Canadian Egress
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.010.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
619
600
23 5/8
24 3/8
447
473
18 5/8
17 5/8
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
719
700
27 9/16
28 5/16
547
573
22 9/16
21 9/16
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
83 7
/16
2119
82 1
1/16
2100
CA1 0621 L CA2 1221 LR CA2 1221 LF CA1 0721 L CA2 1421 LR CA2 1421 LF
76 7
/16
1942
77 1
/2
1968
71 5
/8
1819
1800
70 7
/8
CA1 0618 L CA2 1218 LR CA2 1218 LF CA1 0718 L CA2 1418 LR CA2 1418 LF
64 5
/8
1642
1668
65 1
1/16
1619
63 3
/4
160063
CA1 0616 L CA2 1216 LR CA2 1216 LF CA1 0716 L CA2 1416 LR CA2 1416 LF
1442
56 3
/4
1468
57 1
3/16
1519
59 1
3/16
1500
59 1
/16
CA1 0615 L CA2 1215 LR CA2 1215 LF CA1 0715 L CA2 1415 LR CA2 1415 LF
1342
52 1
3/16
1368
53 7
/8
55 7
/8
1419
1400
55 1
/8
CA1 0614 L CA2 1214 LR CA2 1214 LF CA1 0714 L CA2 1414 LR CA2 1414 LF
48 7
/8
1242
1268
49 1
5/16
23 5/8" (600 MM) COMBINATIONS 27 9/16" (700 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A11
Canadian Egress
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.011.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
597
623
24 1/2
23 1/2
769
750
29 1/2
30 1/4
597
623
24 1/2
23 1/2
1519
1500
59
59 3/4
597
623
24 1/2
23 1/2
1519
1500
59
59 3/4
647
673
26 1/2
25 1/2
819
800
31 1/2
32 1/4
647
673
26 1/2
25 1/2
1619
1600
63
63 3/4
48 1219
47 1
/4
1200 41 1042
42 1
/16
1068
CA1 7512 L CA2 1512 LR CA2 1512 LF CA1 0812 L CA2 1612 LR CA2 1612 LF
40 1
/8
1019
1000
39 3
/8
33 1
/8
842
868
34 3
/16
CA1 7510 L CA2 1510 LR CA2 1510 LF CA1 0810 L CA2 1610 LR CA2 1610 LF
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
CA1 7509 L CA2 1509 LR CA2 1509 LF CA1 0809 L CA2 1609 LR CA2 1609 LF
819
32 1
/4
800
31 1
/2
642
25 1
/4
668
26 5
/16
CA1 7508 L CA2 1508 LR CA2 1508 LF CA1 0808 L CA2 1608 LR CA2 1608 LF
769
30 1
/4
750
29 1
/2
592
23 5
/16
618
24 5
/16
CA1 7575 L CA2 1575 LR CA2 1575 LF CA1 0875 L CA2 1675 LR CA2 1675 LF
719
28 5
/16
700
27 9
/16
542
21 5
/16
568
22 3
/8
CA1 7507 L CA2 1507 LR CA2 1507 LF CA1 0807 L CA2 1607 LR CA2 1607 LF
24 3
/8
619
600
23 5
/8
17 3
/8
442
468
18 7
/16
CA1 7506 L CA2 1506 LR CA2 1506 LF CA1 0806 L CA2 1606 LR CA2 1606 LF
647
673
26 1/2
25 1/2
1619
1600
63
63 3/4
29 1/2" (750 MM) COMBINATIONS 31 1/2" (800 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A12
Canadian Egress
U.S.A. Egress
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.012.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
597
623
24 1/2
23 1/2
769
750
29 1/2
30 1/4
597
623
24 1/2
23 1/2
1519
1500
59
59 3/4
597
623
24 1/2
23 1/2
1519
1500
59
59 3/4
647
673
26 1/2
25 1/2
819
800
31 1/2
32 1/4
647
673
26 1/2
25 1/2
1619
1600
63
63 3/4
48 7
/8
1242
1268
49 1
5/16
55 7
/8
1419
1400
55 1
/8
CA1 7514 L CA2 1514 LR CA2 1514 LF CA1 0814 L CA2 1614 LR CA2 1614 LF
1442
56 3
/4
1468
57 1
3/16
1619
63 3
/4
160063
CA1 7516 L CA2 1516 LR CA2 1516 LF CA1 0816 L CA2 1616 LR CA2 1616 LF
64 5
/8
1642
1668
65 1
1/16
71 5
/8
1819
1800
70 7
/8
CA1 7518 L CA2 1518 LR CA2 1518 LF CA1 0818 L CA2 1618 LR CA2 1618 LF
76 7
/16
1942
77 1
/2
1968
83 7
/16
2119
82 1
1/16
2100
CA1 7521 L CA2 1521 LR CA2 1521 LF CA1 0821 L CA2 1621 LR CA2 1621 LF
1342
52 1
3/16
1368
53 7
/8
1519
59 1
3/16
1500
59 1
/16
CA1 7515 L CA2 1515 LR CA2 1515 LF CA1 0815 L CA2 1615 LR CA2 1615 LF
647
673
26 1/2
25 1/2
1619
1600
63
63 3/4
29 1/2" (750 MM) COMBINATIONS 31 1/2" (800 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A13
Canadian Egress
U.S.A. Egress
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
919
900
35 7/16
36 3/16
747
773
30 7/16
29 7/16
1819
1800
70 7/8
71 5/8
747
773
30 7/16
29 7/16
1819
1800
70 7/8
71 5/8
747
773
30 7/16
29 7/16
32 1
/4
819
800
31 1
/2
25 1
/4
642
668
26 5
/16
CA1 0908 L CA2 1808 LR CA2 1808 LF
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
CA1 0909 L CA2 1809 LR CA2 1809 LF
40 1
/8
1019
1000
39 3
/8
33 1
/8
842
868
34 3
/16
CA1 0910 L CA2 1810 LR CA2 1810 LF
48
1219
1200
47 1
/4
41 1042
1068
42 1
/16
CA1 0912 L CA2 1812 LR CA2 1812 LF
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
49 1
5/16
CA1 0914 L CA2 1814 LR CA2 1814 LF
35 7/16" (900 MM) COMBINATIONS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.013.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard Maxim hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A14
Canadian Egress
U.S.A. Egress
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
919
900
35 7/16
36 3/16
747
773
30 7/16
29 7/16
1819
1800
70 7/8
71 5/8
747
773
30 7/16
29 7/16
1819
1800
70 7/8
71 5/8
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
53 7
/8
CA1 0915 L CA2 1815 LFCA2 1815 LR
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
CA1 0916 L CA2 1816 LFCA2 1816 LR
71 5
/8
1819
1800
70 7
/8
64 5
/8
1642
1668
65 1
1/16
CA1 0918 L CA2 1818 LFCA2 1818 LR
83 7
/16
2119
2100
82 1
1/16
76 7
/16
1942
1968
77 1
/2
CA1 0921 L CA2 1821 LFCA2 1821 LR
747
773
30 7/16
29 7/16
35 7/16" (900 MM) COMBINATIONS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.014.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A15
Canadian Egress
U.S.A. Egress
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
1219
1200
47 1/4
48
247
273
10 3/4
9 3/4
1519
1500
59 1/16
59 13/16
347
373
14 11/16
13 11/16
1819
1800
70 7/8
71 5/8
447
473
18 5/8
17 5/8
2119
2100
82 11/16
83 7/16
547
573
22 9/16
21 9/16
24 3
/8
619
600
23 5
/8
17 3
/8
442
468
18 7
/16
CA3 1206 LFR CA3 1506 LFR CA3 1806 LFR CA3 2106 LFR
28 5
/16
719
700
27 9
/16
21 5
/16
542
568
22 3
/8
CA3 1207 LFR CA3 1507 LFR CA3 1807 LFR CA3 2107 LFR
30 1
/4
769
750
29 1
/2
23 5
/16
592
618
24 5
/16
CA3 1275 LFR CA3 1575 LFR CA3 1875 LFR CA3 2175 LFR
32 1
/4
819
800
31 1
/2
25 1
/4
642
668
26 5
/16
CA3 1208 LFR CA3 1508 LFR CA3 1808 LFR CA3 2108 LFR
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
CA3 1209 LFR CA3 1509 LFR CA3 1809 LFR CA3 2109 LFR
40 1
/8
1019
1000
39 3
/8
33 1
/8
842
868
34 3
/16
CA3 1210 LFR CA3 1510 LFR CA3 1810 LFR CA3 2110 LFR
48 1219
1200
47 1
/4
41 1042
1068
42 1
/16
CA3 1212 LFR CA3 1512 LFR CA3 1812 LFR CA3 2112 LFR
15 1/4" (400 MM) TO 27 9/16" (700 MM) THREE WIDE CASEMENT COMBINATIONS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.015.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A16
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
1219
1200
47 1/4
48
247
273
10 3/4
9 3/4
2119
2100
82 11/16
83 7/16
547
573
22 9/16
21 9/16
1819
1800
70 7/8
71 5/8
447
473
18 5/8
17 5/8
1519
1500
59 1/16
59 13/16
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
49 1
5/16
CA3 1214 LFR CA3 2114 LFRCA3 1814 LFRCA3 1514 LFR
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
53 7
/8
CA3 1215 LFR CA3 2115 LFRCA3 1815 LFRCA3 1515 LFR
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
CA3 1216 LFR CA3 2116 LFRCA3 1816 LFRCA3 1516 LFR
71 5
/8
1819
1800
70 7
/8
64 5
/8
1642
1668
65 1
1/16
CA3 1218 LFR CA3 2118 LFRCA3 1818 LFRCA3 1518 LFR
83 7
/16
2119
2100
82 1
1/16
76 7
/16
1942
1968
77 1
/2
CA3 1221 LFR CA3 2121 LFRCA3 1821 LFRCA3 1521 LFR
347
373
14 11/16
13 11/16
15 3/4" (400 MM) TO 27 9/16" (700 MM) THREE WIDE CASEMENT COMBINATIONS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.016.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A17
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
2269
2250
88 9/16
89 5/16
597
623
24 1/2
23 1/2
2419
2400
94 1/2
95 1/4
647
673
26 1/2
25 1/2
24 3
/8
619
600
23 5
/8
17 3
/8
442
468
18 7
/16
CA3 2306 LFR CA3 2406 LFR
28 5
/16
719
700
27 9
/16
21 5
/16
542
568
22 3
/8
CA3 2307 LFR CA3 2407 LFR
CA3 2375 LFR
30 1
/4
769
750
29 1
/2
23 5
/16
592
618
24 5
/16
CA3 2475 LFR
2719
2700
106 5/16
107 1/16
747
773
30 7/16
29 7/16
32 1
/4
819
800
31 1
/2
25 1
/4
642
668
26 5
/16
CA3 2308 LFR CA3 2408 LFR CA3 2708 LFR
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
CA3 2309 LFR CA3 2409 LFR CA3 2709 LFR
40 1
/8
1019
1000
39 3
/8
33 1
/8
842
868
34 3
/16
CA3 2310 LFR CA3 2410 LFR CA3 2710 LFR
48 1219
1200
47 1
/4
41 1042
1068
42 1
/16
CA3 2312 LFR CA3 2412 LFR CA3 2712 LFR
29 1/2" (750 MM) TO 35 7/16" (900 MM) THREE WIDE CASEMENT COMBINATIONS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.017.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A18
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
2269
2250
88 9/16
89 5/16
597
623
24 1/2
23 1/2
2719
2700
106 5/16
107 1/16
747
773
30 7/16
29 7/16
2419
2400
94 1/2
95 1/4
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
49 1
5/16
CA3 2314 LFR CA3 2714 LFRCA3 2414 LFR
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
53 7
/8
CA3 2315 LFR CA3 2715 LFRCA3 2415 LFR
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
CA3 2316 LFR CA3 2716 LFRCA3 2416 LFR
71 5
/8
1819
1800
70 7
/8
64 5
/8
1642
1668
65 1
1/16
CA3 2318 LFR CA3 2718 LFRCA3 2418 LFR
83 7
/16
2119
2100
82 1
1/16
76 7
/16
1942
1968
77 1
/2
CA3 2321 LFR CA3 2721 LFRCA3 2421 LFR
647
673
26 1/2
25 1/2
29 1/2" (750 MM) TO 35 7/16" (900 MM) THREE WIDE CASEMENT COMBINATIONS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.018.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A19
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
2419
2400
94 1/2
95 1/4
447 - 1047 - 447
473 - 1073 - 473
18 5/8 - 42 1/4 - 18 5/8
17 5/8 - 41 1/4 - 17 5/8
2619
2600
102 3/8
103 1/8
447 - 1247 - 447
473 - 1273 - 473
18 5/8 - 50 1/8 - 18 5/8
17 5/8 - 49 1/8 - 17 5/8
2819
2800
110 1/4
111
447 - 1447 - 447
473 - 1473 - 473
18 5/8 - 58 - 18 5/8
17 5/8 - 56 15/16 - 17 5/8
32 1
/4
819
800
31 1
/2
25 1
/4
642
668
26 5
/16
PCF3 2408 LFR PCF3 2608 LFR PCF3 2808 LFR
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
PCF3 2409 LFR PCF3 2609 LFR PCF3 2809 LFR
40 1
/8
1019
1000
39 3
/8
33 1
/8
842
868
34 3
/16
PCF3 2410 LFR PCF3 2610 LFR PCF3 2810 LFR
48 1219
1200
47 1
/4
41 1042
1068
42 1
/16
PCF3 2412 LFR PCF3 2612 LFR PCF3 2812 LFR
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
49 1
5/16
PCF3 2414 LFR PCF3 2614 LFR PCF3 2814 LFR
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
53 7
/8
PCF3 2415 LFR PCF3 2615 LFR PCF3 2815 LFR
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
PCF3 2416 LFR PCF3 2616 LFR PCF3 2816 LFR
71 5
/8
1819
1800
70 7
/8
PCF3 2418 LFR PCF3 2618 LFR PCF3 2818 LFR
64 5
/8
1642
1668
65 1
1/16
CASEMENT COMBINATIONS WITH 23 5/8" (600 MM) FLANKERS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.019.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A20
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
419
400
15 3/4
16 1/2
247
273
10 3/4
9 3/4
619
600
23 5/8
24 3/8
447
473
18 5/8
17 5/8
819
800
31 1/2
32 1/4
647
673
26 1/2
25 1/2
919
900
35 7/16
36 3/16
747
773
30 7/16
29 7/16
719
700
27 9/16
28 5/16
547
573
22 9/16
21 9/16
519
500
19 11/16
20 7/16
347
373
14 11/16
13 11/16
769
750
29 1/2
30 1/4
16 1
/2
419
400
15 3
/4
CA1 0404 CA1 0604 CA1 0804 CA1 0904
9 1/
2
242
268
10 9
/16
CA1 0704CA1 0504 CA1 7504
20 7
/16
519
500
19 1
1/16
CA1 0405 CA1 0605 CA1 0805 CA1 0905
13 7
/16
342
368
14 1
/2
CA1 0705CA1 0505 CA1 7505
24 3
/8
619
600
23 5
/8
CA1 0406 CA1 0606 CA1 0806 CA1 0906
17 3
/8
442
468
18 7
/16
CA1 0706CA1 0506 CA1 7506
28 5
/16
719
700
27 9
/16
CA1 0407 CA1 0607 CA1 0807 CA1 0907
21 5
/16
542
568
22 3
/8
CA1 0707CA1 0507 CA1 7507
30 1
/4
769
750
29 1
/2
CA1 0475 CA1 0675 CA1 0875 CA1 0975
23 5
/16
592
618
24 5
/16
CA1 0775CA1 0575 CA1 7575
32 1
/4
819
800
31 1
/2
CA1 0408 CA1 0608 CA1 0808 CA1 0908
25 1
/4
642
668
26 5
/16
CA1 0708CA1 0508 CA1 7508
36 3
/16
919
900
35 7
/16
CA1 0409 CA1 0609 CA1 0809 CA1 0909
29 3
/16
742
768
30 1
/4
CA1 0709CA1 0509 CA1 7509
40 1
/8
1019
1000
39 3
/8
CA1 0410 CA1 0610 CA1 0810 CA1 0910
33 1
/8
842
868
34 3
/16
CA1 0710CA1 0510 CA1 7510
597
623
24 1/2
23 1/2
FIXED CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available as Push Out style Fixed.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A21
CSMT.E.001.0.2004CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
419
400
15 3/4
16 1/2
247
273
10 3/4
9 3/4
519
500
19 11/16
20 7/16
347
373
14 11/16
13 11/16
619
600
23 5/8
24 3/8
447
473
18 5/8
17 5/8
719
700
27 9/16
28 5/16
547
573
22 9/16
21 9/16
769
750
29 1/2
30 1/4
597
623
24 1/2
23 1/2
819
800
31 1/2
32 1/4
647
673
26 1/2
25 1/2
919
900
35 7/16
36 3/16
48 1219
1200
47 1
/4
41 1042
1068
42 1
/16
CA1 0412 CA1 0512 CA1 0612 CA1 0712 CA1 7512 CA1 0812 CA1 0912
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
49 1
5/16
CA1 0414 CA1 0514 CA1 0614 CA1 0714 CA1 7514 CA1 0814 CA1 0914
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
53 7
/8
CA1 0415 CA1 0515 CA1 0615 CA1 0715 CA1 7515 CA1 0815 CA1 0915
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
CA1 0416 CA1 0516 CA1 0616 CA1 0716 CA1 7516 CA1 0816 CA1 0916
747
773
30 7/16
29 7/16
71 5
/8
1819
1800
70 7
/8
64 5
/8
1642
1668
65 1
1/16
CA1 0418 CA1 0518 CA1 0618 CA1 0718 CA1 7518 CA1 0818 CA1 0918
83 7
/16
2119
2100
82 1
1/16
76 7
/16
1942
1968
77 1
/2CA1 0421 CA1 0521 CA1 0621 CA1 0721 CA1 7521 CA1 0821 CA1 0921
95 1
/4
2419
2400
94 1
/2
88 1
/4
2242
2268
89 5
/16
CA1 0524 CA1 0624 CA1 0724 CA1 7524 CA1 0824 CA1 0924
FIXED CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available as Push Out style Fixed.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A22
CSMT.E.002.0.2004 CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
1019
1000
39 3/8
40 1/8
847
873
34 3/8
33 3/8
1219
1200
47 1/4
48
1047
1073
42 1/4
41 1/4
1419
1400
55 1/8
55 7/8
1247
1273
50 1/8
49 1/8
1519
1500
59 1/16
59 13/16
1347
1373
54 1/16
53 1/16
1619
1600
63
63 3/4
1447
1473
58
56 15/16
16 1
/2
419
400
15 3
/4
9 1/
2
242
268
10 9
/16
CA1 1004 CA1 1204 CA1 1404 CA1 1504 CA1 1604
20 7
/16
519
500
19 1
1/16
13 7
/16
342
368
14 1
/2
CA1 1005 CA1 1205 CA1 1405 CA1 1505 CA1 1605
24 3
/8
619
600
23 5
/8
17 3
/8
442
468
18 7
/16
CA1 1006 CA1 1206 CA1 1406 CA1 1506 CA1 1606
28 5
/16
719
700
27 9
/16
21 5
/16
542
568
22 3
/8
CA1 1007 CA1 1207 CA1 1407 CA1 1507 CA1 1607
30 1
/4
769
750
29 1
/2
23 5
/16
592
618
24 5
/16
CA1 1075 CA1 1275 CA1 1475 CA1 1575 CA1 1675
32 1
/4
819
800
31 1
/2
25 1
/4
642
668
26 5
/16
CA1 1008 CA1 1208 CA1 1408 CA1 1508 CA1 1608
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
CA1 1009 CA1 1209 CA1 1409 CA1 1509 CA1 1609
40 1
/8
1019
1000
39 3
/8
33 1
/8
842
868
34 3
/16
CA1 1010 CA1 1210 CA1 1410 CA1 1510 CA1 1610
FIXED CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available as Push Out style Fixed.
• Available with Mission Sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A23
CSMT.E.003.0.2004CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
1419
1400
55 1/8
55 7/8
1247
1273
50 1/8
49 1/8
1519
1500
59 1/16
59 13/16
1347
1373
54 1/16
53 1/16
1619
1600
63
63 3/4
1447
1473
58
56 15/16
1019
1000
39 3/8
40 1/8
847
873
34 3/8
33 3/8
1219
1200
47 1/4
48
1047
1073
42 1/4
41 1/4
48 1219
1200
47 1
/4
41 1042
1068
42 1
/16
CA1 1412 CA1 1512 CA1 1612CA1 1012 CA1 1212
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
49 1
5/16
CA1 1414 CA1 1514 CA1 1614CA1 1014 CA1 1214
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
53 7
/8
CA1 1415 CA1 1515 CA1 1615CA1 1015 CA1 1215
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
CA1 1416 CA1 1516 CA1 1616CA1 1016 CA1 1216
71 5
/8
1819
1800
70 7
/8
64 5
/8
1642
1668
65 1
1/16
CA1 1418 CA1 1518 CA1 1618CA1 1018 CA1 1218
83 7
/16
2119
2100
82 1
1/16
76 7
/16
1942
1968
77 1
/2CA1 1421 CA1 1521 CA1 1621CA1 1021 CA1 1221
95 1
/4
2419
2400
94 1
/2
88 1
/4
2242
2268
89 5
/16
CA1 1024 CA1 1224
FIXED CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available as Push Out style Fixed.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A24
CSMT.E.004.0.2004 CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
1819
1800
70 7/8
71 5/8
1647
1673
65 7/8
64 13/16
2019
2000
78 3/4
79 1/2
1847
1873
73 3/4
72 11/16
2419
2400
94 1/2
95 1/4
2247
2273
89 1/2
88 7/16
16 1
/2
419
400
15 3
/4
9 1/
2
242
268
10 9
/16
CA1 1804 CA1 2004 CA1 2404
20 7
/16
519
500
19 1
1/16
13 7
/16
342
368
14 1
/2
CA1 1805 CA1 2005 CA1 2405
24 3
/8
619
600
23 5
/8
17 3
/8
442
468
18 7
/16
CA1 1806 CA1 2006 CA1 2406
28 5
/16
719
700
27 9
/16
21 5
/16
542
568
22 3
/8
CA1 1807 CA1 2007 CA1 2407
30 1
/4
769
750
29 1
/2
23 5
/16
592
618
24 5
/16
CA1 1875 CA1 2075 CA1 2475
32 1
/4
819
800
31 1
/2
25 1
/4
642
668
26 5
/16
CA1 1808 CA1 2008 CA1 2408
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
CA1 1809 CA1 2009 CA1 2409
FIXED CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available as Push Out style Fixed.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A25
CSMT.E.005.0.2004CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
2419
2400
94 1/2
95 1/4
2247
2273
89 1/2
88 7/16
2019
2000
78 3/4
79 1/2
1847
1873
73 3/4
72 11/16
1819
1800
70 7/8
71 5/8
1647
1673
65 7/8
64 13/16
48 1219
1200
47 1
/4
41 1042
1068
42 1
/16
CA1 2412CA1 2012CA1 1812
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
49 1
5/16
CA1 2014CA1 1814
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
53 7
/8
CA1 2015CA1 1815
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
CA1 2016CA1 1816
71 5
/8
1819
1800
70 7
/8
64 5
/8
1642
1668
65 1
1/16
CA1 1818
40 1
/8
1019
1000
39 3
/8
CA1 2410CA1 2010CA1 1810
33 1
/8
842
868
34 3
/16
FIXED CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available as Push Out style Fixed.
• Available with Mission Sash.
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A26
CSMT.E.006.0.2004 CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
1019
1000
39 3/8
40 1/8
368
393
15 1/2
14 7/16
1219
1200
47 1/4
48
468
493
19 7/16
18 3/8
1419
1400
55 1/8
55 7/8
568
593
23 3/8
22 5/16
1519
1500
59 1/16
59 13/16
618
643
25 5/16
24 5/16
1619
1600
63
63 3/4
668
693
27 1/4
26 1/4
32 1
/4
819
800
31 1
/2
25 1
/4
642
26 5
/16
10 9
/16
FCA 1008 LR FCA 1208 LR FCA 1408 LR FCA 1508 LR FCA 1608 LR
1819
1800
70 7/8
71 5/8
768
793
31 1/4
30 3/16
36 3
/16
919
900
35 7
/16
29 3
/16
742
768
30 1
/4
FCA 1009 LR FCA 1209 LR FCA 1409 LR FCA 1509 LR FCA 1609 LR FCA 1809 LR
40 1
/8
1019
1000
39 3
/8
33 1
/8
842
868
34 3
/16
FCA 1010 LR FCA 1210 LR FCA 1410 LR FCA 1510 LR FCA 1610 LR FCA 1810 LR
48 1219
1200
47 1
/4
41 1042
1068
42 1
/16
FCA 1012 LR FCA 1212 LR FCA 1412 LR FCA 1512 LR FCA 1612 LR FCA 1812 LR
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
53 7
/8FCA 1015 LR FCA 1215 LR FCA 1415 LR FCA 1515 LR FCA 1615 LR FCA 1815 LR
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
FCA 1016 LR FCA 1216 LR FCA 1416 LR FCA 1516 LR FCA 1616 LR FCA 1816 LR
FCA 1018 LR FCA 1218 LR FCA 1418 LR FCA 1518 LR FCA 1618 LR
71 5
/8
1819
1800
70 7
/8
64 5
/8
1642
1668
65 1
1/16
FCA 1818 LR
55 7
/8
1419
1400
55 1
/8
48 7
/8
1242
1268
41 1
5/16
FCA 1014 LR FCA 1214 LR FCA 1414 LR FCA 1514 LR FCA 1614 LR FCA 1814 LR
FRENCH CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOW ELEVATIONS
CSMT.E.020.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm) from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are forillustration purposes only – please verify SDL/Grille patterns before confirming your order.
• Available with Mission sash (must be Push Out style).
• All information is subject to HP1 glazing.
• Meet Canada/U.S.A. egress with standard hardware and double sash.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A27
Canadian Egress
U.S.A. Egress
METRIC
IMPERIAL
1200
475600
R1500
2000
39160
0
R2500
1500
39960
0
R1500
2100
36960
0
R2500
1600
36960
0
R1500
2400
35060
0
R3000
R3000
1800
30060
0
R1500
2600
30460
0
2700
27960
0R3000
2800
25360
0
R3000
3000
26260
0
R3500
3200
21360
0
3500
59 1/1615 1
1/16
23 5
/8
R 59 1/16
110 1/4
1023 5
/8
R 118 1/8
63
14 1
/2
23 5
/8
R 59 1/16
118 1/810 5
/16
23 5
/8
R 137 13/16
70 7/811 1
3/16
23 5
/8
R 59 1/16
126
8 3/
8
23 5
/8
R 137 13/16
47 1/418
11/
16
23 5
/8
R 59 1/16
82 11/16
14 1
/2
23 5
/8
R 98 7/16
94 1/2
13 3
/4
23 5
/8
R 118 1/8
102 3/811 1
5/16
23 5
/8
118 1/8
78 3/4
15 3
/823
5/8
R 98 7/16
106 5/16
1123 5
/8
R 118 1/8
CAMBER TOP CASEMENT STANDARD RADIUS
CSMT.E.029.0.2004 CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A28
Not to Scale
TRADITIONAL CAMBER TOP CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• 59 1/16" (1500 mm) radius.
• For egress information on this product contact LoewenArchitectural Services.
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
519
500
19 11/16
20 7/16
347
373
14 11/16
13 11/16
819
800
31 1/2
32 1/4
247
273
10 3/4
9 3/4
819
800
31 1/2
32 1/4
247
273
10 3/4
9 3/4
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
419
400
15 3/4
16 1/2
247
273
10 3/4
9 3/4
769
30 1
/4
750
29 1
/2
590
23 1
/4
616
24 1
/4
CTC10575 L0875 LR
CTC20875 LFCTC2
1075 LRCTC2
1075 LFCTC2CTC1
0475 L
819
32 1
/4
800
31 1
/2
640
25 3
/16
666
26 1
/4
CTC10508 L0808 LR
CTC20808 LFCTC2
1008 LRCTC2
1008 LFCTC2CTC1
0408 L
36 3
/16
919
900
35 7
/16
29 1
/8
740
766
30 3
/16
CTC10509 L0809 LR
CTC20809 LFCTC2
1009 LRCTC2
1009 LFCTC2CTC1
0409 L
40 1
/8
1019
1000
39 3
/8
33 1
/16
840
866
34 1
/8
CTC10510 L0810 LR
CTC20810 LFCTC2
1010 LRCTC2
1010 LFCTC2CTC1
0410 L
48 1219
47 1
/4
1200
40 1
5/16
1040 42 1066
CTC10512 L0812 LR
CTC20812 LFCTC2
1012 LRCTC2
1012 LFCTC2CTC1
0412 L
719
28 5
/16
700
27 9
/16
540
21 1
/4
566
22 5
/16
CTC10507 L
CTC20807 LR
CTC20807 LF
CTC21007 LR
CTC21007 LF
CTC10407 L
15 3/4" (400 MM) COMBINATIONS 19 11/16" (500 MM) COMBINATIONS
CSMT.E.021.0.2004CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A29
TRADITIONAL CAMBER TOP CASEMENT WINDOW ELEVATIONS
CSMT.E.022.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• 59 1/16" (1500 mm) radius.
• For egress information on this product contact LoewenArchitectural Services.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
419
400
15 3/4
16 1/2
247
273
10 3/4
9 3/4
819
800
31 1/2
32 1/4
247
273
10 3/4
9 3/4
819
800
31 1/2
32 1/4
247
273
10 3/4
9 3/4
519
500
19 11/16
20 7/16
347
373
14 11/16
13 11/16
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
55 7
/8
1419
1400
55 1
/8
48 1
3/16
1240
1266
49 7
/8
CTC10414 L
CTC20814 LR
CTC20814 LF
CTC10514 L
CTC21014 LR
CTC21014 LF
1519
59 1
3/16
1500
59 1
/16
1340
52 3
/4
1366
53 1
3/16
CTC10415 L
CTC20815 LR
CTC20815 LF
CTC10515 L
CTC21015 LR
CTC21015 LF
1619
63 3
/4
160063 1440
56 1
1/16
1466
57 3
/4
CTC10416 L
CTC20816 LR
CTC20816 LF
CTC10516 L
CTC21016 LR
CTC21016 LF
71 5
/8
1819
1800
70 7
/8
64 9
/16
1640
1666
65 5
/8
CTC10418 L
CTC20818 LR
CTC20818 LF
CTC10518 L
CTC21018 LR
CTC21018 LF
83 7
/16
2119
82 1
1/16
2100
76 3
/8
1940
77 7
/16
1966
CTC10421 L
CTC20821 LR
CTC20821 LF
CTC10521 L
CTC21021 LR
CTC21021 LF
15 3/4" (400 MM) COMBINATIONS 19 11/16" (500 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A30
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
619
600
23 5/8
24 3/8
447
473
18 5/8
17 5/8
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
719
700
27 9/16
28 5/16
547
573
22 9/16
21 9/16
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
48 1219
47 1
/4
1200
CTC10612 L
CTC21212 LR
CTC21212 LF
CTC10712 L
CTC21412 LR
CTC21412 LF
40 1
5/16
1040 42 1066
40 1
/8
1019
1000
39 3
/8
CTC10610 L
CTC21210 LR
CTC21210 LF
CTC10710 L
CTC21410 LR
CTC21410 LF
33 1
/16
840
866
34 1
/8
819
32 1
/4
800
31 1
/2
CTC10608 L
CTC21208 LR
CTC21208 LF
CTC10708 L
CTC21408 LR
CTC21408 LF
640
25 3
/16
666
26 1
/4
719
28 5
/16
700
27 9
/16
CTC10607 L
CTC21207 LR
CTC21207 LF
CTC10707 L
CTC21407 LR
CTC21407 LF
540
21 1
/4
566
22 5
/16
769
30 1
/4
750
29 1
/2
CTC10675 L
CTC21275 LR
CTC21275 LF
CTC10775 L
CTC21475 LR
CTC21475 LF
590
23 1
/4
616
24 1
/4
36 3
/16
919
900
35 7
/16
CTC10609 L
CTC21209 LR
CTC21209 LF
CTC10709 L
CTC21409 LR
CTC21409 LF
29 1
/8
740
766
30 3
/16
23 5/8" (600 MM) COMBINATIONS 27 9/16" (700 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A31
TRADITIONAL CAMBER TOP CASEMENT WINDOW ELEVATIONS
CSMT.E.023.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• 59 1/16" (1500 mm) radius.
• For egress information on this product contact LoewenArchitectural Services.
CAD DOWNLOAD: www.loewen.com/architect
TRADITIONAL CAMBER TOP CASEMENT WINDOW ELEVATIONS
CSMT.E.024.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• 59 1/16" (1500 mm) radius.
• For egress information on this product contact LoewenArchitectural Services.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
619
600
23 5/8
24 3/8
447
473
18 5/8
17 5/8
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
719
700
27 9/16
28 5/16
547
573
22 9/16
21 9/16
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
83 7
/16
2119
82 1
1/16
2100
CTC10621 L
CTC21221 LR
CTC21221 LF
CTC10721 L
CTC21421 LR
CTC21421 LF
76 3
/8
1940
77 7
/16
1966
71 5
/8
1819
1800
70 7
/8
CTC10618 L
CTC21218 LR
CTC21218 LF
CTC10718 L
CTC21418 LR
CTC21418 LF
64 9
/16
1640
1666
65 5
/8
1619
63 3
/4
160063
CTC10616 L
CTC21216 LR
CTC21216 LF
CTC10716 L
CTC21416 LR
CTC21416 LF
1440
56 1
1/16
1466
57 3
/4
1519
59 1
3/16
1500
59 1
/16
CTC10615 L
CTC21215 LR
CTC21215 LF
CTC10715 L
CTC21415 LR
CTC21415 LF
1340
52 3
/4
1366
53 1
3/16
55 7
/8
1419
1400
55 1
/8
CTC10614 L
CTC21214 LR
CTC21214 LF
CTC10714 L
CTC21414 LR
CTC21414 LF
48 1
3/16
1240
1266
49 7
/8
23 5/8" (600 MM) COMBINATIONS 27 9/16" (700 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A32
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
769
750
29 1/2
30 1/4
597
623
24 1/2
23 1/2
1519
1500
59 1/16
59 13/16
597
623
24 1/2
23 1/2
1519
1500
59 1/16
59 13/16
597
623
24 1/2
23 1/2
819
800
31 1/2
32 1/4
647
673
26 1/2
25 1/2
1619
1600
63
63 3/4
647
673
26 1/2
25 1/2
1619
1600
63
63 3/4
647
673
26 1/2
25 1/2
719
28 5
/16
700
27 9
/16
540
21 1
/4
566
22 5
/16
CTC17507 F
CTC21507 FF
CTC21507 FF
CTC10807 F
CTC21607 FF
CTC21607 FF
769
30 1
/4
750
29 1
/2
590
23 1
/4
616
24 1
/4
CTC17575 F
CTC21575 FF
CTC21575 FF
CTC10875 F
CTC21675 FF
CTC21675 FF
819
32 1
/4
800
31 1
/2
640
25 3
/16
666
26 1
/4
CTC17508 L
CTC21508 LR
CTC21508 LF
CTC10808 F
CTC21608 FF
CTC21608 FF
36 3
/16
919
900
35 7
/16
29 1
/8
740
766
30 3
/16
CTC17509 L
CTC21509 LR
CTC21509 LF
CTC10809 L
CTC21609 LR
CTC21609 LF
40 1
/8
1019
1000
39 3
/8
33 1
/16
840
866
34 1
/8
CTC17510 L
CTC21510 LR
CTC21510 LF
CTC10810 L
CTC21610 LR
CTC21610 LF
48 1219
47 1
/4
1200
40 1
5/16
1040 42 1066
CTC17512 L
CTC21512 LR
CTC21512 LF
CTC10812 L
CTC21612 LR
CTC21612 LF
29 1/2" (750 MM) COMBINATIONS 31 1/2" (800 MM) COMBINATIONS
TRADITIONAL CAMBER TOP CASEMENT WINDOW ELEVATIONS
CSMT.E.025.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• 59 1/16" (1500 mm) radius.
• For egress information on this product contact LoewenArchitectural Services.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A33
TRADITIONAL CAMBER TOP CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• 59 1/16" (1500 mm) radius.
• For egress information on this product contact LoewenArchitectural Services.
CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
in.
mmVisible
Glass
GlassSize
769
750
29 1/2
30 1/4
597
623
24 1/2
23 1/2
1519
1500
59 1/16
59 13/16
597
623
24 1/2
23 1/2
1519
1500
59 1/16
59 13/16
597
623
24 1/2
23 1/2
819
800
31 1/2
32 1/4
647
673
26 1/2
25 1/2
1619
1600
63
63 3/4
647
673
26 1/2
25 1/2
1619
1600
63
63 3/4
647
673
26 1/2
25 1/2
55 7
/8
1419
1400
55 1
/8
48 1
3/16
1240
1266
49 7
/8
CTC17514 L
CTC21514 LR
CTC21514 LF
CTC10814 L
CTC21614 LR
CTC21614 LF
1519
59 1
3/16
1500
59 1
/16
1340
52 3
/4
1366
53 1
3/16
CTC17515 L
CTC21515 LR
CTC21515 LF
CTC10815 L
CTC21615 LR
CTC21615 LF
CTC17516 L
CTC21516 LR
CTC21516 LF
CTC10816 L
CTC21616 LR
1619
63 3
/4
160063 1440
56 1
1/16
1466
57 3
/4
CTC21616 LF
71 5
/8
1819
1800
70 7
/8
64 9
/16
1640
1666
65 5
/8
CTC17518 L
CTC21518 LR
CTC21518 LF
CTC10818 L
CTC21618 LR
CTC21618 LF
83 7
/16
2119
82 1
1/16
2100
76 3
/8
1940
77 7
/16
1966
CTC17521 L
CTC21521 LR
CTC21521 LF
CTC10821 L
CTC21621 LR
CTC21621 LF
29 1/2" (750 MM) COMBINATIONS 31 1/2" (800 MM) COMBINATIONS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A34
CSMT.E.026.0.2004
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
919
900
35 7/16
36 3/16
747
773
30 7/16
29 7/16
1819
1800
70 7/8
71 5/8
747
773
30 7/16
29 7/16
1819
1800
70 7/8
71 5/8
747
773
30 7/16
29 7/16
32 1
/4
819
800
31 1
/2
25 3
/16
640
666
26 1
/4
CTC1 0908 F CTC2 1808 FF CTC2 1808 FF
36 3
/16
919
900
35 7
/16
29 1
/8
740
766
30 3
/16
CTC1 0909 F CTC2 1809 FF CTC2 1809 FF
40 1
/8
1019
1000
39 3
/8
33 1
/16
840
866
34 1
/8
CTC1 0910 L CTC2 1810 LR CTC2 1810 LF
48 1219
1200
47 1
/4
40 1
5/16
1040
106642
CTC1 0912 L CTC2 1812 LR CTC2 1812 LF
35 7/16" (900 MM) COMBINATIONS
TRADITIONAL CAMBER TOP CASEMENT WINDOW ELEVATIONS
CSMT.E.027.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• 59 1/16" (1500 mm) radius.
• For egress information on this product contact LoewenArchitectural Services.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A35
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
919
900
35 7/16
36 3/16
747
773
30 7/16
29 7/16
1819
1800
70 7/8
71 5/8
747
773
30 7/16
29 7/16
1819
1800
70 7/8
71 5/8
747
773
30 7/16
29 7/16
55 7
/8
1419
1400
55 1
/8
48 1
3/16
1240
1266
49 7
/8
CTC1 0914 L CTC2 1814 LR CTC2 1814 LF
59 1
3/16
1519
1500
59 1
/16
52 3
/4
1340
1366
53 1
3/16
CTC1 0915 L CTC2 1815 LR CTC2 1815 LF
63 3
/4
1619
160063
56 1
1/16
1440
1466
57 3
/4
CTC1 0916 L CTC2 1816 LR CTC2 1816 LF
83 7
/16
2119
2100
82 1
1/16
76 3
/8
1940
1966
77 7
/16
CTC1 0921 L CTC2 1821 LR CTC2 1821 LF
71 5
/8
1819
1800
70 7
/8
CTC1 0918 L CTC2 1818 LR CTC2 1818 LF
64 9
/16
1640
1666
65 5
/8
35 7/16" (900 MM) COMBINATIONS
TRADITIONAL CAMBER TOP CASEMENT WINDOW ELEVATIONS
CSMT.E.028.0.2004
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• All information is subject to HP1 glazing.
• 59 1/16" (1500 mm) radius.
• For egress information on this product contact LoewenArchitectural Services.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A36
TRADITIONAL HALF ROUND CASEMENT WINDOW ELEVATIONS
CSMT.E.030.0.2004
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
619
600
23 5/8
24 3/8
447
473
18 5/8
17 5/8
1019
40 1
/8
1000
39 3
/8
842
33 1
/8
868
34 3
/16
CTC 0610 L
719
700
27 9/16
28 5/16
547
573
22 9/16
21 9/16
819
800
31 1/2
32 1/4
647
673
26 1/2
25 1/2
919
900
35 7/16
36 3/16
747
773
30 7/16
29 7/16
769
750
29 1/2
30 1/4
121948 1200
47 1
/4
104241 1068
42 1
/16
CTC 0612 L CTC 0712 L CTC 0812 LCTC 7512 L
1419
55 7
/8
1400
55 1
/8
1242
48 7
/8
1268
49 1
5/16
CTC 0614 L CTC 0714 L CTC 0814 L CTC 0914 LCTC 7514 L
59 1
3/16
1519
1500
59 1
/16
52 1
3/16
1342
1368
55 1
/8
CTC 0615 L CTC 0715 L CTC 0815 L CTC 0915 LCTC 7515 L
63 3
/4
1619
160063
56 3
/4
1442
1468
57 1
3/16
CTC 0616 L CTC 0716 L CTC 0816 L CTC 0916 LCTC 7516 L
71 5
/8
1819
70 7
/8
1800
64 5
/8
1642
65 1
1/16
1668
CTC 0618 L CTC 0718 L CTC 0818 L CTC 0918 LCTC 7518 L
83 7
/16
2119
82 1
1/16
2100
76 7
/16
1942
77 1
/2
1968
CTC 0621 L CTC 0721 L CTC 0821 LCTC 7521 L
597
623
24 1/2
23 1/2
23 5/8" (600 MM) TO 35 7/16"(900 MM) HALF ROUND CASEMENTS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• Half round radii are calculated by dividing the unit OSMby 2. E.g. Unit CTF 0610 L has an OSM of 23 5/8" (600 mm) divided by 2 will equal 11 13/16" (300 mm).
• All information is subject to HP1 glazing.
• For egress information on this product contact LoewenArchitectural Services.
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A37
TRADITIONAL QUARTER ROUND CASEMENT WINDOW ELEVATIONS
CSMT.E.031.0.2004 CAD DOWNLOAD: www.loewen.com/architect
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
1019
1000
39 3/8
40 1/8
347
373
14 11/16
13 11/16
519
500
19 11/16
20 7/16
59 1
3/16
1519
1500
59 1
/16
52 9
/16
1335
1363
53 1
1/16
CTC2 1015 LFCTC2 1015 LRCTC1 0515 L
63 3
/4
1619
160063
56 1
/2
1435
1463
57 5
/8
CTC2 1016 LFCTC2 1016 LRCTC1 0516 L
71 5
/8
1819
1800
70 7
/8
CTC2 1018 LF
64 3
/8
1635
1663
65 1
/2
CTC2 1018 LRCTC1 0518 L
83 7
/16
2119
2100
82 1
1/16
76 1
/4
1936
1964
77 5
/16
CTC2 1021 LFCTC2 1021 LRCTC1 0521 L
347
373
14 11/16
13 11/16
9 11/16" (500 MM) COMBINATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• Half round radii are calculated by dividing the unit OSMby 2. E.g. Unit CTF 0610 L has an OSM of 23 5/8" (600 mm) divided by 2 will equal 11 13/16" (300 mm).
• All information is subject to HP1 glazing.
• For egress information on this product contact LoewenArchitectural Services.
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A38
TRADITIONAL QUARTER ROUND CASEMENT WINDOW ELEVATIONS
Note: • For a unit with a Mission sash, subtract 3/4" (20 mm)from the vertical glass measurement.
• SDL/Grille patterns are dependent on SDL/Grille type. All patterns shown in this catalog are for illustrationpurposes only – please verify SDL/Grille patterns beforeconfirming your order.
• Available with Push Out hardware.
• Available with Mission sash.
• Half round radii are calculated by dividing the unit OSMby 2. E.g. Unit CTF 0610 L has an OSM of 23 5/8" (600 mm) divided by 2 will equal 11 13/16" (300 mm).
• All information is subject to HP1 glazing.
• For egress information on this product contact LoewenArchitectural Services.
UnitO.S.M.
RoughOpening
in.
mm
in.
mm
in.
mm
in.
mmVisible
Glass
GlassSize
83 7
/16
2119
2100
82 1
1/16
71 5
/8
1819
1800
70 7
/8
619
600
23 5/8
24 3/8
447
473
18 5/8
17 5/8
CTC10618 L
CTC10621 L
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
CTC21218 LR
CTC21221 LR
1219
1200
47 1/4
48
447
473
18 5/8
17 5/8
CTC21218 LF
CTC21221 LF
719
700
27 9/16
28 5/16
547
573
22 9/16
21 9/16
CTC10721 L
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
CTC21421 LR
1419
1400
55 1/8
55 7/8
547
573
22 9/16
21 9/16
CTC21421 LF
1936
76 1
/4
1964
77 5
/16
64 7
/16
1636
1664
65 1
/2
23 5/8" (600 MM) COMBINATIONS 27 9/16" (700 MM) COMBINATIONS
CSMT.E.032.0.2004CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A39
WOOD TRIPLE 6 9/16" (166 mm)
HEAD
SILL
(166)
6 9/16"
(29)
1 1/8"
OU
TSID
E M
EASU
REM
ENT
ROU
GH
OPE
NIN
G
METAL CLAD DOUBLE 4 9/16" (116 mm)
SILL
HEAD
OU
TSID
E M
EASU
REM
ENT
ROU
GH
OPE
NIN
G
(116)
4 9/16"
(30)
1 3/16"
METAL CLAD DOUBLE 4 9/16" (116 mm)
OUTSIDE MEASUREMENT
ROUGH OPENING
(116
)
4 9/
16"
(30)
1 3/
16"
WOOD TRIPLE 6 9/16" (166 mm)
OUTSIDE MEASUREMENT
ROUGH OPENING
(166
)
6 9/
16"
(29)
1 1/
8"
SIDE JAMB SIDE JAMB
SIDE JAMBSIDE JAMB
Note: • Other jamb widths available.
• All dimensions to have +/– 1/16" (2 mm) tolerance.
CASEMENT WINDOW/WALL CONNECTION DETAILS
CSMT.D.001.0.2004
HEAD & SILL DETAILS 3"=1'- 0"
PLAN VIEW – METAL CLAD & WOOD 3"=1'- 0"
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A40
METAL CLAD
WOOD
(19)
3/4"
(19)
3/4"
(70)
2 3/4"(32)
1 1/4"
(76)
3"(152)
6"
(76)
3"
(19)
3/4"
(19)
3/4"
(70)
2 3/4"(32)
1 1/4"
(152)
6"
(76)
3"
(76)
3"
METAL CLAD TRIPLE6 9/16" (166 mm)
WOOD DOUBLE4 9/16" (116 mm)
WOOD TRIPLE6 9/16" (166 mm)
HEAD HEADHEAD
(52)
2 1/
16"(76)3"
(50)
1 15/16"
(35)
1 3/
8"
(30)
1 3/16"
(166)
6 9/16"
(16)
5/8"
(35)
1 3/
8"
(54)
2 1/
8"
(54)
2 1/
8"(35)
1 3/
8"
(33)
1 5/
16"
(116)
4 9/16"
(29)
1 1/8"
(52)
2 1/
16"(7
6)3"
(52)
2 1/
16"(7
6)3"
(50)
1 15/16"
(33)
1 5/
16"
(29)
1 1/8"
(166)
6 9/16"
(35)
1 3/
8"(16)
5/8"
SILL SILL
(57)
(57)(57)
2 1/
4"
(82)
3 3/
16"
(57)
2 1/4"(7
0)
2 3/
4"
(16)
5/8"
2 1/4"
2 1/
4"
(82)
3 3/
16"
(35)
1 3/
8"
(70)
2 3/
4"
SILL
(43)
1 11/16"
(70)
2 3/
4"
(57)
2 1/
4"
(82)
3 3/
16"
(12)
7/16
"
METAL CLAD DOUBLE4 9/16" (116 mm)
SILL
HEAD
(35)
1 3/
8"
(70)
2 3/
4"
(54)
2 1/
8"(35)
1 3/
8"(116)
4 9/16"
(30)
1 3/16"
(35)
1 3/
8"
(52)
2 1/
16"(7
6)
3 "
(43)
1 11/16"
(82)
3 3/
16" (5
7)
2 1/
4"
VIS
IBLE
GLA
SS
OU
TSID
E M
EASU
REM
ENT
Note: • Other jamb widths available.
SIDE JAMBSIDE JAMB
SIDE JAMBSIDE JAMB
• All dimensions to have +/– 1/16" (2 mm) tolerance.
PLAN VIEW 3"=1'- 0"
CASEMENT WINDOW DETAILS
HEAD & SILL DETAILS 3"=1'- 0"
Not to Scale
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A41
CSMT.D.002.0.2004CAD DOWNLOAD: www.loewen.com/architect
METAL CLAD TRIPLE6 9/16" (166 mm)
WOOD TRIPLE6 9/16" (166 mm)
WOOD DOUBLE4 9/16" (116 mm)
HEAD HEADHEAD
(166)(30)
(50)
(52)
(35)
(16)
(76)
(52)
(35)
(54)
(16)
SILL SILLSILL
(82)
(57)
(16) (3
5)
(12)
(82)
(57)
(54)
(43)
(16)
2 1/
16"(7
6)3"
1 15/16"(3
5)
1 3/
8"
1 3/16" 6 9/16"
1 3/
8"5/8"
2 1/
8"
1 3/
8"
(33)
1 5/
16"
(116)
4 9/16"
(29)
1 1/8"
2 1/
16"3"
(52)
2 1/
16"(7
6)3"
(50)
1 15/16"
(33)
1 5/
16"
(29)
1 1/8"
(166)
6 9/16"
(54)
2 1/
8"
5/8"
(57)
2 1/4"
2 1/
4"
3 3/
16"
5/8"
1 3/
8" 2 1/
8"
1 11/16"2
1/4"
3 3/
16"
(57)
2 1/4"
(57)
2 1/
4"
7/16
"
(82)
3 3/
16"
5/8" (3
5)
1 3/
8"
METAL CLAD
WOOD
(152)
(76) (76)
(152)
(76) (76)
6"
3" 3"
(8)
5/16"
(8)
5/16"
(70)
(32)2 3/4"
1 1/4"
6"
3" 3"
(8)
5/16"
(8)
5/16"(32)
(70)
2 3/4"
1 1/4"METAL CLAD DOUBLE4 9/16" (116 mm)
Note: • Other jamb widths available.
HEAD
SILL
(54)
(52)
(76)
(57)
(82)
(43)
1 11/16"
2 1/
4"
3 3/
16"
2 1/
16"
3"
(30)
1 3/16"
(35)
1 3/
8"
(116)
4 9/16"
(35)
1 3/
8" (54)
2 1/
8"2
1/8"
(35)
1 3/
8"
VIS
IBLE
GLA
SS
OU
TSID
E M
EASU
REM
ENT
SIDE JAMB
SIDE JAMB
SIDE JAMB
SIDE JAMB
• All dimensions to have +/– 1/16" (2 mm) tolerance.
PUSH OUT CASEMENT WINDOW DETAILS
CSMT.D.003.0.2004
HEAD & SILL DETAILS 3"=1'- 0"
PLAN VIEW 3"=1'- 0"Not to Scale
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A42
SILL
HEAD
(76)
(52)
(35)
(30) (116)
(35)
(54)
(43)
(35)
(57)
(82)
(54)
1 3/
8"
2 1/
8"
1 3/
8"
4 9/16" 1 3/16"
1 3/
8"
2 1/
16"
VIS
IBLE
GLA
SS
3"
1 11/16"
3 3/
16" 2 1/
4"
OU
TSID
E M
EASU
REM
ENT
2 1/
8"
(152)
(76) (76)
(32)
(70) (19) (19)
(152)
(76) (76)
(32)
(70) (19) (19)
SIDE JAMB
SIDE JAMB
SIDE JAMB
SIDE JAMB
3/4" 3/4" 2 3/4"
1 1/4"
3"
6"
3"
3/4" 3/4" 2 3/4"
1 1/4"
6"
3" 3"
METAL CLAD
WOOD Note: • Other jamb widths available.
• All dimensions to have +/ –1/16" (2 mm) tolerance.
METAL CLAD DOUBLE 4 9/16" (116 mm)
HEAD
(166)
(33) (50)
(52)(7
6)
(35)(1
6)
(29)
2 1/
16"3"
1 15/16"
1 5/
16"
1 1/8" 6 9/16"
1 3/
8"5/8"
SILL
(57)
(82)
(57)
(35) (5
4)
2 1/4"
2 1/
4"
3 3/
16"
1 3/
8" 2 1/
8"
WOOD TRIPLE6 9/16" (166 mm)
HEAD
(76)
(52)
(54)(3
5)
(29) (116)
(33)
2 1/
8"1 3/
8"
1 5/
16"
4 9/16"1 1/8"
2 1/
16"3"
SILL
(12)
(82)
(57)
(43)
(54)
1 11/16"
2 1/
4"
3 3/
16"
7/16
"
2 1/
8"
WOOD DOUBLE4 9/16" (116 mm)
HEAD
(166) (30)
(35)
(50)
(76)
(52)
(16)
(35)
(54)
2 1/
16" 3"
1 15/16" 1
3/8"
1 3/16" 6 9/16"
5/8"
1 3/
8"
2 1/
8"
SILL
(57)
(82)
(57)
(16)
(54)
2 1/
4"
3 3/
16"
2 1/4"
5/8"
2 1/
8"
METAL CLAD TRIPLE 6 9/16" (166 mm)
PLAN VIEW 3"=1'- 0"
FIXED CASEMENT WINDOW DETAILS
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A43
CSMT.D.008.0.2005
HEAD & SILL DETAILS 3"=1'- 0"
Not to Scale
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
HEAD & SILL DETAILS 3"=1'- 0"
PLAN VIEW 3"=1'- 0"Not to Scale
A44
MISSION CASEMENT WINDOW DETAILS
METAL CLAD TRIPLE6 9/16" (166 mm)
WOOD DOUBLE4 9/16" (116 mm)
WOOD TRIPLE6 9/16" (166 mm)
HEADHEADHEAD
(76)
(52)
(16)
(16)
(52)
2 1/
16"(76)3"
(35)
1 3/
8"(30)
1 3/16"
(166)
6 9/16"
(35)
1 3/
8"
(51)2"
(35)
1 3/
8"
5/8"
(33)
1 5/
16"
(116)
4 9/16"
(29)
1 1/8"
2 1/
16"3"
(52)
2 1/
16"(7
6)3"
(33)
1 5/
16"
(29)
1 1/8"
(166)
6 9/16"
METAL CLAD DOUBLE4 9/16" (116 mm)
• Other jamb widths available.
• All dimensions to have +/– 1/16" (2 mm) tolerance.
HEAD
SILL (35)
1 3/
8"
(70)
2 3/
4"(5
1)2"
(35)
1 3/
8"
(57)
2 1/4"
(35)
1 3/
8"
(116)
4 9/16"
(30)
1 3/16"
(53)
2 1/
16"(7
6)3"
(78)
3 1/
16"
(102
)
4"V
ISIB
LE G
LASS
OU
TSID
E M
EASU
REM
ENT
5/8"
(50)
1 15/16"
(50)
1 15/16"
SILL SILLSILL
(70)
(102
) (78)
(57)(1
2)
(70)
(78)
(16) (3
5)
(16)
(57)
2 1/4"
(78)
3 1/
16"
(102
)
4"
2 3/
4"
2 1/4"
3 1/
16"
4"7/
16"
(57)
2 1/4"
3 1/
16"
2 3/
4"
5/8"
1 3/
8"
5/8"
METAL CLAD
WOOD
(152)
6"
(76)
3"
(76)
3"
(19)
3/4"
(19)
3/4"(32)
(70)
2 3/4"
1 1/4"
(19)
3/4"
(19)
3/4"(32)
(70)
2 3/4"
1 1/4"
(152)
6"
(76)
3"
(76)
3"
SIDE JAMB
SIDE JAMB
Note: • Also available in Push Out.
SIDE JAMB
SIDE JAMB
CSMT.D.004.0.2004 CAD DOWNLOAD: www.loewen.com/architect
Note: • Other jamb widths available.
WOOD
SID
E J
AM
B
SID
E J
AM
B
(76)
(52)
(112) (76)
(52) (52) (52)
(116
)(2
9)
(116
)
(43)
(35) (16) (50)
(48)
1 7/8"
1 11
/16"
6 9/
16"
(29)
1 1/
8"2 1/16"2 1/16"2 1/16"2 1/16"
3"VISIBLE GLASS4 3/8"VISIBLE GLASS3"
4 9/
16"
1 1/
8"
1 3/8" 5/8"
1 15
/16"
METAL CLAD
SID
E J
AM
B
SID
E J
AM
B
(16)
(116
)(3
0)
(43)
(166
)(3
0)
(76)
(52) (52) (52)
(112) (76)
(52)
(50)
(35)
1 3/8"
6 9/
16"
1 3/
16"
(48)
1 7/8"
1 11
/16"
2 1/16"2 1/16"2 1/16"2 1/16"
3"VISIBLE GLASS4 7/16"VISIBLE GLASS3"
4 9/
16"
1 3/
16"
5/8"
1 15
/16"
WOOD DOUBLE4 9/16" (116 mm)
HEAD
SILL
(12)
(51)
2 1/
8"
(70)
2 3/
4"
(116)
4 9/16"
(29)
1 1/8"
(33)
1 5/
16"
(35)
1 3/
8"
(35)
1 3/
8"
(76)3"
(82)
3 3/
16"
7/16
"
(52)
2 1/
16"
(57)
2 1/
4"
(43)
1 11/16"VIS
IBLE
GLA
SS
OU
TSID
E M
EASU
REM
ENT
METAL CLAD DOUBLE4 9/16" (116 mm)
HEAD
SILL
(70)
2 3/
4"
(35)
1 3/
8"
(51)2"
(35)
1 3/
8"
(43)
1 11/16"
(52)
2 1/
16"
(57)
2 1/
4"
(81)
3 3/
16"
(76)3"
(35)
1 3/
8"
(30)
1 3/16"
(116)
4 9/16"
VIS
IBLE
GLA
SS
OU
TSID
E M
EASU
REM
ENT
• All dimensions to have +/– 1/16" (2 mm) tolerance.
PLAN VIEW Not to Scale
FRENCH CASEMENT WINDOW DETAILS
HEAD & SILL DETAILS 3"=1'- 0"
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A45
CSMT.D.006.0.2004
SILL
HEAD HEAD
SILL
SCREEN ANDSCREEN HARDWAREARE SHOWNIN DASHED LINES
SCREEN ANDSCREEN HARDWAREARE SHOWNIN DASHED LINES
(30)
1 3/16"
(116)
4 9/16"
(35)
1 3/
8"
(35)
1 3/
8"
(54)
2 1/
8"
(76)3"
(52)
2 1/
16"
(57)
2 1/
4"
(81)
3 3/
16"
(35)
1 3/
8" (54)
2 1/
8"
VIS
IBLE
GLA
SS
OU
TSID
E M
EASU
REM
ENT
(33)
1 5/
16"
(43)
1 11/16"
(81)
3 3/
16" (5
7)
2 1/
4"
(12)
7/16
"
(54)
2 1/
8"
(35)
1 3/
8"
(54)
2 1/
8"
(52)
2 1/
16"(7
6)3"
(35)
1 3/
8"
(116)
4 9/16"
(29)
1 1/8"
(43)
1 11/16"
OU
TSID
E M
EASU
REM
ENT
VIS
IBLE
GLA
SS
VISIBLE GLASS
(45)
1 3/4"
(43)
1 11
/16"
(112)
4 3/8"
(50)
1 15
/16"
(116
)
4 9/
16"
(29)
1 1/
8"
(76)
3"
(52)
2 1/16"
(52)
2 1/16"
(52)
2 1/16"
VISIBLE GLASS
(52)
2 1/16"
(76)
3"
(166
)
6 9/
16"
(29)
1 1/
8"
SCREEN AND SCREEN HARDWAREARE SHOWN IN DASHED LINES
METAL CLAD
(52)
2 1/16"
(52)
2 1/16"
(52)
2 1/16"
(52)
2 1/16"
(76)
3" VISIBLE GLASS
(112)
4 7/16"
(43)
1 11
/16"
VISIBLE GLASS
(76)
3"
(30)
1 3/
16"
(116
)
4 9/
16"
(30)
1 3/
16"
(166
)
6 9/
16"
(50)
1 15
/16"
(35)
1 3/8"
(45)
1 3/4"
SCREEN AND SCREEN HARDWAREARE SHOWN IN DASHED LINES
WOOD
Note: • Other jamb widths available.
WOOD DOUBLE4 9/16" (116 mm)
METAL CLAD DOUBLE4 9/16" (116 mm)
• All dimensions to have +/– 1/16" (2 mm) tolerance.
SID
E J
AM
B
SID
E J
AM
BSI
DE
JA
MB
SID
E J
AM
B
PUSH OUT FRENCH CASEMENT WINDOW DETAILS
CSMT.D.007.0.2004
HEAD & SILL DETAILS 3"=1'- 0"
PLAN VIEW Not to Scale
CAD DOWNLOAD: www.loewen.com/architect
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A46
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A47
METAL CLAD TRIPLE6 9/16" (166 mm)
WOOD TRIPLE6 9/16" (166 mm)
WOOD DOUBLE4 9/16" (116 mm)
(16)
(16)
SILL SILLSILL
(16)
(12)
(16)
(52)
2 1/
16"(76)3"
(50)
1 15/16"
(35)
1 3/
8"
(30)
1 3/16"
(166)
6 9/16"
(54)
2 1/
8"
5/8"
(54)
2 1/
8"
(33)
1 5/
16"
(116)
4 9/16"
(29)
1 1/8"
(76)3"
(52)
2 1/
16"
(52)
2 1/
16"
(50)
1 15/16"
(33)
1 5/
16"
(29)
1 1/8"
(166)
6 9/16"
5/8"
(35)
1 3/
8"
(57)
2 1/4"
(57)
2 1/
4"
(82)
3 3/
16"
5/8"
(70)
2 3/
4"
(35)
1 3/
8"
(70)
2 3/
4"
(43)
1 11/16"
(57)
2 1/
4"(8
2)
3 3/
16"
(57)
2 1/4"
(57)
2 1/
4"
7/16
"
(82)
3 3/
16"
(35)
1 3/
8"
5/8"
METAL CLAD DOUBLE4 9/16" (116 mm)
Note: • Other jamb widths available.
SILL
RADIUSCOMPONENT
(35)
1 3/
8"
(70)
2 3/
4"
(54)
2 1/
8"(35)
1 3/
8"
(35)
1 3/
8"
(116)
4 9/16"
(30)
1 3/16"
(52)
2 1/
16"(7
6)3"
(43)1 11/16"
(82)
3 3/
16" (5
7)
2 1/
4"
VIS
IBLE
GLA
SS
OU
TSID
E M
EASU
REM
ENT
METAL CLAD
WOOD
(19)
3/4"
(19)
3/4"(32)
(70)
2 3/4"
1 1/4"
(152)
6"
(76)
3"
(76)
3"
(152)
6"
(76)
3"
(76)
3"
(19)
3/4"
(19)
3/4"(32)
(70)
2 3/4"
1 1/4"
HEAD HEAD HEAD
SIDE JAMB SIDE JAMB
SIDE JAMB SIDE JAMB
HEAD
• All dimensions to have +/– 1/16" (2 mm) tolerance.
RADIUS TOP CASEMENT WINDOW DETAILS
CSMT.D.005.0.2004
HEAD & SILL DETAILS 3"=1'- 0"
CAD DOWNLOAD: www.loewen.com/architect
PLAN VIEW 3"=1'- 0" Not to Scale
AAMA/WDMA 101/I.S.2-97 – U.S.A.
Product Type Unit Size Air Leakage Water Leakage Structural Forced Entry
Casement 35 7/16" x 70 7/8" Pass C-HC100 C-HC60(Non Clad) (900 mm x 1800 mm) 0.029 ft3/m/ft2 @ 15.00 psf @ 90.0 psf Not Tested
@ 75 Pa (720 Pa) (4320 Pa)
Casement 27 9/16" x 59 1/16" C-R60(Metal Clad with (700 mm x 1500 mm) Not Tested Not Tested @ 90.0 psf Not Tested2 point Mirage locks) (4320 Pa)
Casement 35 7/16" x 70 7/8" Pass C-C90 C-C65(Metal Clad with (900 mm x 1800 mm) 0.0085 ft3/m/ft2 @ 13.5 psf @ 97.5 psf F103 point Mirage locks) @ 75 Pa (650 Pa) (4680 Pa)
Push Out Casement 23 5/8" x 47 1/4" Pass C-R75 C-R45(Non Clad) (600 mm x 1200 mm) 0.009 ft3/m/ft2 @ 11.25 psf @ 67.5 psf N/A
@ 75 Pa (540 Pa) (3230 Pa)
Push Out Casement 23 5/8" x 47 1/4" Pass C-R75 C-R45(Metal Clad) (600 mm x 1200 mm) 0.0085 ft3/m/ft2 @ 11.25 psf @ 67.5 psf N/A
@ 75 Pa (540 Pa) (3230Pa)
Push Out Casement 35 7/16" x 70 7/8" Pass C-LC85 C-LC35(Non Clad) (900 mm x 1800 mm) 0.003 ft3/m/ft2 @ 12.75 psf @ 52.5 psf N/A
@ 75 Pa (620 Pa) (2520 Pa)
Push Out Casement 35 7/16" x 70 7/8" Pass C-LC85 C-LC35(Metal Clad) (900 mm x 1800 mm) 0.0045 ft3/m/ft2 @ 12.75 psf @ 52.5 psf N/A
@ 75 Pa (620 Pa) (2520 Pa)
Fixed Casement 94 1/2" x 63" Pass F-C100 F-C70(Non Clad) (2400 mm x 1600 mm) 0 ft3/m/ft2 @15.0 psf @ 105.0 psf F10
@ 75 Pa (720 Pa) (5040 Pa)
Fixed Casement 78 3/4" x 63" Pass F-HC100 F-HC40(Metal Clad) (2000 mm x 1600 mm) 0.015 ft3/m/ft2 @15.0 psf @ 60.0 psf N/A
@ 300 Pa (720 Pa) (2880 Pa)
CSA A440-00 – CANADA
Product Type Unit Size Air Leakage Water Leakage Structural Forced Entry
Casement 35 7/16" x 70 7/8" A3 B7 C4(Non Clad) (900 mm x 1800 mm) 0.060 m3/hr/m @ 700 Pa @ 4000 Pa F10
@ 75 Pa (14.63 psf) (83.54 psf)
Casement 27 9/16" x 63" A3 B7 C3(Metal Clad with (700 mm x 1600 mm) 0.11 m3/hr/m @ 700 Pa @ 3000 Pa F10Mirage locks) @ 75 Pa (14.63 psf) (62.5 psf)
Casement 27 9/16" x 59 1/16" C4(Metal Clad with (700 mm x 1500 mm) Not Tested Not Tested @ 4000 Pa Not Tested2 point Mirage locks) (83.54 psf)
Casement 35 7/16" x 70 7/8" A3 B7 C4(Metal Clad with (900 mm x 1800 mm) 0.050 m3/hr/m @ 700 Pa @ 4000 Pa F103 point Mirage locks) @ 75 Pa (14.63 psf) (83.54 psf)
Push Out Casement 23 5/8" x 47 1/4" A3 B7 C3(Non Clad) (600 mm x 1200 mm) 0.041 m3/hr/m @ 700 Pa @ 3000 Pa F1
@ 75 Pa (14.63 psf) (62.5 psf)
Push Out Casement 23 5/8" x 47 1/4" A3 B7 C3(Metal Clad) (600 mm x 1200 mm) 0.039 m3/hr/m @ 700 Pa @ 3000 Pa F1
@ 75 Pa (14.63 psf) (62.5 psf)
Push Out Casement 35 7/16" x 70 7/8" A3 B7 C2(Non Clad) (900 mm x 1800 mm) 0.021 m3/hr/m @ 700 Pa @ 2000 Pa F1
@ 75 Pa (14.63 psf) (41.8 psf)
Push Out Casement 35 7/16" x 70 7/8" A3 B7 C2(Metal Clad) (900 mm x 1800 mm) 0.028 m3/hr/m @ 700 Pa @ 2000 Pa F1
@ 75 Pa (14.63 psf) (41.8 psf)
Fixed Casement 94 1/2" x 63" A3 B7 C5(Non Clad) (2400 mm x 1600 mm) 0.00 m3/hr/m @ 700 Pa @ 5000 Pa F10
@ 75 Pa (14.63 psf) (104.42 psf)
Fixed Casement 78 3/4" x 63" Fixed B7 C3(Metal Clad) (2000 mm x 1600 mm) 0.075 m3/hr/m @ 700 Pa @ 3000 Pa N/A
@ 75 Pa (14.63 psf) (62.65 psf)
CASEMENT WINDOW PERFORMANCE RATINGS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A48
NFRC U-FACTOR AND SHGC/VT – NON CLAD
Product Type Glazing Type Spacer Gap Fill 1 Gap Fill 2 U-Factor Res SHGC (max) VT (max)
Casement Double Clear Standard Air - 0.45 0.52 0.55Double Clear Standard Argon - 0.43 0.52 0.55
HP1 Standard Air - 0.33 0.28 0.48HP1 Standard Argon - 0.30 0.28 0.48HP2 Standard Air - 0.27 0.26 0.44HP2 Standard Argon - 0.25 0.26 0.44HP3 Standard Air - 0.23 0.24 0.38HP3 Standard Argon - 0.21 0.24 0.38HP1 Thermal Edge Air - 0.33 0.28 0.48HP1 Thermal Edge Argon - 0.30 0.28 0.48HP2 Thermal Edge Air - 0.26 0.26 0.44HP2 Thermal Edge Argon - 0.24 0.26 0.44HP3 Thermal Edge Air - 0.22 0.24 0.38HP3 Thermal Edge Argon - 0.20 0.24 0.38
Triple Clear Standard Air Air 0.33 0.47 0.50Triple Clear Standard Argon Argon 0.31 0.47 0.50
Double Sun 240 Standard Air - 0.34 0.18 0.27Double Sun 240 Standard Argon - 0.31 0.17 0.27Triple Sun 240 Standard Air Air 0.27 0.16 0.24Triple Sun 240 Standard Argon Argon 0.26 0.16 0.24
Triple Sun 240 Dual Low E Standard Air Air 0.24 0.14 0.21Triple Sun 240 Dual Low E Standard Argon Argon 0.21 0.14 0.21
Push Out Casement Double Clear Standard Air - 0.45 0.52 0.55Double Clear Standard Argon - 0.44 0.52 0.55
HP1 Standard Air - 0.34 0.28 0.48HP1 Standard Argon - 0.31 0.28 0.48HP2 Standard Air Air 0.28 0.26 0.44HP2 Standard Argon Argon 0.26 0.26 0.44HP3 Standard Air Air 0.24 0.24 0.38HP3 Standard Argon Argon 0.22 0.24 0.38HP1 Thermal Edge Air - 0.33 0.28 0.48HP1 Thermal Edge Argon - 0.30 0.28 0.48HP2 Thermal Edge Air Air 0.27 0.26 0.44HP2 Thermal Edge Argon Argon 0.25 0.26 0.44HP3 Thermal Edge Air Air 0.23 0.24 0.38HP3 Thermal Edge Argon Argon 0.21 0.24 0.38
Triple Clear Standard Air Air 0.33 0.47 0.50Triple Clear Standard Argon Argon 0.32 0.47 0.50
Double Sun 240 Standard Air - 0.34 0.18 0.27Double Sun 240 Standard Argon - 0.31 0.17 0.27Triple Sun 240 Standard Air Air 0.28 0.16 0.24Triple Sun 240 Standard Argon Argon 0.26 0.16 0.24
Triple Sun 240 Dual Low E Standard Air Air 0.24 0.14 0.21Triple Sun 240 Dual Low E Standard Argon Argon 0.22 0.14 0.21
Fixed Casement Double Clear Standard Air - 0.46 0.61 0.64Double Clear Standard Argon - 0.44 0.61 0.64
HP1 Standard Air - 0.32 0.33 0.56HP1 Standard Argon - 0.29 0.32 0.56HP1 Thermal Edge Air - 0.32 0.33 0.56HP1 Thermal Edge Argon - 0.28 0.32 0.56
Double Sun 240 Standard Air - 0.33 0.20 0.31Double Sun 240 Standard Argon - 0.29 0.20 0.31
CASEMENT WINDOW PERFORMANCE RATINGS
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A49
NFRC U-FACTOR AND SHGC/VT – ALUMINUM CLAD
Product Type Glazing Type Spacer Gap Fill 1 Gap Fill 2 U-Factor Res SHGC (max) VT (max)
Casement Double Clear Standard Air - 0.49 0.52 0.53Double Clear Standard Argon - 0.47 0.52 0.53
HP1 Standard Air - 0.37 0.29 0.47HP1 Standard Argon - 0.34 0.29 0.47HP2 Standard Argon Air 0.28 0.26 0.42HP3 Standard Air Air 0.26 0.24 0.37HP3 Standard Argon Argon 0.24 0.24 0.37HP1 Thermal Edge Argon - 0.33 0.29 0.47HP2 Thermal Edge Argon Air 0.27 0.26 0.42HP3 Thermal Edge Argon Argon 0.22 0.24 0.37
Double Sun 240 Standard Air - 0.38 0.25 0.29Double Sun 240 Standard Argon - 0.36 0.24 0.29Triple Sun 240 Standard Air Air 0.31 0.22 0.27Triple Sun 240 Standard Argon Air 0.29 0.22 0.27
Triple Sun 240 Dual Low E Standard Air Air 0.26 0.18 0.23Triple Sun 240 Dual Low E Standard Argon Argon 0.24 0.18 0.23
Push Out Casement Double Clear Standard Air - 0.46 0.61 0.64Double Clear Standard Argon - 0.45 0.61 0.64
HP1 Standard Air - 0.33 0.33 0.56HP1 Standard Argon - 0.29 0.33 0.56HP2 Standard Air - 0.26 0.30 0.51HP2 Standard Argon - 0.24 0.30 0.51HP3 Standard Air - 0.22 0.28 0.45HP3 Standard Argon - 0.19 0.28 0.45HP1 Thermal Edge Air - 0.32 0.33 0.56HP1 Thermal Edge Argon - 0.29 0.33 0.56HP2 Thermal Edge Air - 0.25 0.30 0.51HP2 Thermal Edge Argon - 0.23 0.30 0.51HP3 Thermal Edge Air - 0.21 0.28 0.45HP3 Thermal Edge Argon - 0.18 0.28 0.45
Triple Clear Standard Air Air 0.33 0.55 0.59Triple Clear Standard Argon Argon 0.31 0.55 0.59
Double Sun 240 Standard Air - 0.33 0.21 0.31Double Sun 240 Standard Argon - 0.30 0.20 0.31Triple Sun 240 Standard Air Air 0.27 0.19 0.29Triple Sun 240 Standard Argon Argon 0.24 0.18 0.29
Triple Sun 240 Dual Low E Standard Air Air 0.22 0.17 0.25Triple Sun 240 Dual Low E Standard Argon Argon 0.19 0.16 0.25
Fixed Casement Double Clear Standard Air - 0.46 0.61 0.64Double Clear Standard Argon - 0.45 0.61 0.64
HP1 Standard Air - 0.33 0.33 0.56HP1 Standard Argon - 0.29 0.33 0.56HP2 Standard Air Air 0.26 0.30 0.51HP2 Standard Argon Air 0.24 0.30 0.51HP3 Standard Air Air 0.22 0.28 0.45HP3 Standard Argon Argon 0.19 0.28 0.45HP1 Thermal Edge Air - 0.32 0.33 0.56HP1 Thermal Edge Argon - 0.29 0.33 0.56HP2 Thermal Edge Air Air 0.25 0.30 0.51HP2 Thermal Edge Argon Argon 0.23 0.30 0.51HP3 Thermal Edge Air Air 0.21 0.28 0.45HP3 Thermal Edge Argon Argon 0.18 0.28 0.45
Triple Clear Standard - - 0.33 0.55 0.59Triple Clear Standard - - 0.31 0.55 0.59
Double Sun 240 Standard - - 0.33 0.21 0.31Double Sun 240 Standard - - 0.30 0.20 0.31Triple Sun 240 Standard Air Air 0.27 0.17 0.29Triple Sun 240 Standard Argon Air 0.24 0.17 0.29
Triple Sun 240 Dual Coating Standard Air Air 0.22 0.15 0.25Triple Sun 240 Dual Coating Standard Argon Argon 0.19 0.15 0.25
CASEMENT WINDOW PERFORMANCE RATINGS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A50
JIS
Product Type Air Leakage Water Leakage Structural
Casement A-4 W-5 S-70.43 m3/h/m2 @ Upper limit = 750 Pa @ Upper limit = +3600 Pa
@ 100 Pa @ Lower limit = 250 Pa @ Lower limit = -3600 Pa
BFRC U-FACTOR
Total WindowProduct Type Size Glazing U (W/m2K)
14 7/16" x 58 1/4" HP1 [3-12-3 Low E2 172 (S2) Argon] 1.6Non Clad Casement/Picture for L1 (1230 mm x 1480 mm) HP2 [3-12-3-12-3 Low E2 172 (S2) Argon] 1.4
HP3 [3-12-3-12-3 Low E2 172 (S2 & S5) Argon] 1.2
14 7/16" x 58 1/4" HP1 [3-12-3 Low E2 172 (S2) Argon] 1.7Metal Clad Casement/Picture for L1 (1230 mm x 1480 mm) HP2 [3-12-3-12-3 Low E2 172 (S2) Argon] 1.5
HP3 [3-12-3-12-3 Low E2 172 (S2 & S5) Argon] 1.3
14 7/16" x 58 1/4" HP1 [3-12-3 Low E2 172 (S2) Argon] 1.6Non Clad Casement/Fixed Picture for L1 (1230 mm x 1480 mm) HP2 [3-12-3-12-3 Low E2 172 (S2) Argon] 1.4
HP3 [3-12-3-12-3 Low E2 172 (S2 & S5) Argon] 1.2
14 7/16" x 58 1/4" HP1 [3-12-3 Low E2 172 (S2) Argon] 1.7Metal Clad Casement/Fixed Picture for L1 (1230 mm x 1480 mm) HP2 [3-12-3-12-3 Low E2 172 (S2) Argon] 1.5
HP3 [3-12-3-12-3 Low E2 172 (S2 & S5) Argon] 1.3
ENERGY STAR – U.S.A. REQUIREMENTS
Northern Zone North/Central Zone South/Central Zone Southern ZoneProduct Type (0.35) (0.40/.55) (0.40/.40) (0.65/.40)
Casement Non Clad HP1 Argon HP1 Argon HP1 Argon HP1 Argon
Casement Metal Clad HP1 Argon HP1 Argon HP1 Argon HP1 Argon
MIAMI-DADE COUNTY
Air Water Static Forced Large Missile Cyclic NOAProduct Type Infiltration Infiltration Load Entry (D) Impact Load Number
1.57 psf 10.5 psf +70/-70 psf 300lb – +70/-70 psf –design pressure design pressure
Metal Clad Impact PASS PASS PASS N/A PASS PASS 02-0503.08Fixed Casement
Metal Clad Impact PASS PASS PASS N/A PASS PASS 02-0503.08Fixed Camber Top Casement
Metal Clad Impact PASS PASS PASS N/A PASS PASS 02-0503.08Fixed Half Circle Casement
Metal Clad Impact Outswing PASS PASS PASS PASS PASS PASS 02-0308.08/Casement/Fixed Casement Combo 02-0503.08
Metal Clad Impact Outswing PASS PASS PASS PASS PASS PASS 02-0308.08/Casement/Direct Set Picture Combo 02-0308.09
ENERGY STAR – CANADA REQUIREMENTS
Zone A Zone B Zone C Zone DProduct Type (0.35) (0.32) (0.28) (0.25)
Casement Non Clad HP1 Argon HP1 Argon HP2 Air HP3 Air
Casement Metal Clad HP1 Argon HP2 Air HP2 Argon HP3 Argon
CASEMENT WINDOW PERFORMANCE RATINGS
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A51
CASEMENT WINDOW LIGHT AND VENT SCHEDULE
ModelNumber
ExposedGlass Area
UnitOSM
CA1 0404 15 3/4 15 3/4 0.64 0.89 – – –CA1 0405 15 3/4 19 11/16 0.91 1.21 – – –CA1 0406 15 3/4 23 5/8 1.18 1.53 – – –CA1 0407 15 3/4 27 9/16 1.44 1.85 – – –CA1 0475 15 3/4 29 1/2 1.57 2.01 – – –CA1 0408 15 3/4 31 1/2 1.71 2.17 – – –CA1 0409 15 3/4 35 7/16 1.97 2.49 – – –CA1 0410 15 3/4 39 3/8 2.24 2.81 – – –CA1 0412 15 3/4 47 1/4 2.77 3.45 – – –CA1 0414 15 3/4 55 1/8 3.30 4.09 – – –CA1 0415 15 3/4 59 1/16 3.57 4.41 – – –CA1 0416 15 3/4 63 3.83 4.73 – – –CA1 0418 15 3/4 70 7/8 4.37 5.37 – – –CA1 0421 15 3/4 82 11/16 5.16 6.33 – – –CA1 0504 19 5/8 15 3/4 0.90 1.19 13.58 10.87 1.02CA1 0505 19 5/8 19 11/16 1.28 1.62 13.58 14.80 1.40CA1 0506 19 5/8 23 5/8 1.65 2.05 13.58 18.74 1.77CA1 0507 19 5/8 27 9/16 2.02 2.47 13.58 22.68 2.14CA1 0575 19 5/8 29 1/2 2.21 2.69 13.58 24.65 2.32CA1 0508 19 5/8 31 1/2 2.40 2.90 13.58 26.61 2.51CA1 0509 19 5/8 35 7/16 2.77 3.33 13.58 30.55 2.88CA1 0510 19 5/8 39 3/8 3.14 3.76 13.58 34.49 3.25CA1 0512 19 5/8 47 1/4 3.89 4.61 13.58 42.36 4.00CA1 0514 19 5/8 55 1/8 4.64 5.47 13.58 50.24 4.74CA1 0515 19 5/8 59 1/16 5.01 5.89 13.58 54.17 5.11CA1 0516 19 5/8 63 5.39 6.32 13.58 58.11 5.48CA1 0518 19 5/8 70 7/8 6.13 7.17 13.58 65.98 6.22CA1 0521 19 5/8 82 11/16 7.25 8.46 13.58 77.80 7.34CA1 0604 23 5/8 15 3/4 1.16 1.49 17.52 10.87 1.32CA1 0605 23 5/8 19 11/16 1.65 2.03 17.52 14.80 1.80CA1 0606 23 5/8 23 5/8 2.13 2.56 17.52 18.74 2.28CA1 0607 23 5/8 27 9/16 2.61 3.10 17.52 22.68 2.76CA1 0675 23 5/8 29 1/2 2.85 3.36 17.52 24.65 3.00CA1 0608 23 5/8 31 1/2 3.09 3.63 17.52 26.61 3.24CA1 0609 23 5/8 35 7/16 3.57 4.17 17.52 30.55 3.72CA1 0610 23 5/8 39 3/8 4.05 4.70 17.52 34.49 4.20CA1 0612 23 5/8 47 1/4 5.01 5.77 17.52 42.36 5.15CA1 0614 23 5/8 55 1/8 5.98 6.84 17.52 50.24 6.11CA1 0615 23 5/8 59 1/16 6.46 7.38 17.52 54.17 6.59CA1 0616 23 5/8 63 6.94 7.91 17.52 58.11 7.07CA1 0618 23 5/8 70 7/8 7.90 8.98 17.52 65.98 8.03CA1 0621 23 5/8 82 11/16 9.34 10.59 17.52 77.80 9.46CA1 0704 27 9/16 15 3/4 1.42 – – – –CA1 0705 27 9/16 19 11/16 2.01 2.44 21.46 14.80 2.21CA1 0706 27 9/16 23 5/8 2.60 3.08 21.46 18.74 2.79CA1 0707 27 9/16 27 9/16 3.19 3.72 21.46 22.68 3.38CA1 0775 27 9/16 29 1/2 3.49 4.04 21.46 24.65 3.67CA1 0708 27 9/16 31 1/2 3.78 4.36 21.46 26.61 3.97CA1 0709 27 9/16 35 7/16 4.37 5.01 21.46 30.55 4.55CA1 0710 27 9/16 39 3/8 4.96 5.65 21.46 34.49 5.14CA1 0712 27 9/16 47 1/4 6.14 6.93 21.46 42.36 6.31CA1 0714 27 9/16 55 1/8 7.31 8.22 21.46 50.24 7.49CA1 0715 27 9/16 59 1/16 7.90 8.86 21.46 54.17 8.07CA1 0716 27 9/16 63 8.49 9.50 21.46 58.11 8.66CA1 0718 27 9/16 70 7/8 9.67 10.79 21.46 65.98 9.83CA1 0721 27 9/16 82 11/16 11.43 12.72 21.46 77.80 11.59CA1 7504 29 1/2 15 3/4 1.56 – – – –CA1 7505 29 1/2 19 11/16 2.20 2.64 23.43 14.80 2.41CA1 7506 29 1/2 23 5/8 2.84 3.34 23.43 18.74 3.05CA1 7507 29 1/2 27 9/16 3.48 4.03 23.43 22.68 3.69CA1 7575 29 1/2 29 1/2 3.80 4.38 23.43 24.65 4.01CA1 7508 29 1/2 31 1/2 4.13 4.73 23.43 26.61 4.33CA1 7509 29 1/2 35 7/16 4.77 5.43 23.43 30.55 4.97CA1 7510 29 1/2 39 3/8 5.41 6.12 23.43 34.49 5.61CA1 7512 29 1/2 47 1/4 6.70 7.51 23.43 42.36 6.89CA1 7514 29 1/2 55 1/8 7.98 8.91 23.43 50.24 8.17CA1 7515 29 1/2 59 1/16 8.62 9.60 23.43 54.17 8.81CA1 7516 29 1/2 63 9.27 10.30 23.43 58.11 9.45CA1 7518 29 1/2 70 7/8 10.55 11.69 23.43 65.98 10.73CA1 7521 29 1/2 82 11/16 12.48 13.78 23.43 77.80 12.66
W H ft2
VentOpening
ft2
Egress Opening w/EgressHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
IMPERIAL
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A52
– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – 13.03 10.87 0.98 – – –– – – 13.03 14.80 1.34 – – –– – – 13.03 18.74 1.70 – – –– – – 13.03 22.68 2.05 – – –– – – 13.03 24.65 2.23 – – –– – – 13.03 26.61 2.41 – – –– – – 13.03 30.55 2.76 – – –– – – 13.03 34.49 3.12 – – –– – – 13.03 42.36 3.83 – – –– – – 13.03 50.24 4.55 – – –– – – 13.03 54.17 4.90 – – –– – – 13.03 58.11 5.26 – – –– – – 13.03 65.98 5.97 – – –– – – 13.03 77.80 7.04 – – –
14.45 10.87 1.09 16.97 10.87 1.28 13.90 10.87 1.0514.45 14.80 1.49 16.97 14.80 1.74 13.90 14.80 1.4314.45 18.74 1.88 16.97 18.74 2.21 13.90 18.74 1.8114.45 22.68 2.28 16.97 22.68 2.67 13.90 22.68 2.1914.45 24.65 2.47 16.97 24.65 2.90 13.90 24.65 2.3814.45 26.61 2.67 16.97 26.61 3.14 13.90 26.61 2.5714.45 30.55 3.07 16.97 30.55 3.60 13.90 30.55 2.9514.45 34.49 3.46 16.97 34.49 4.06 13.90 34.49 3.3314.45 42.36 4.25 16.97 42.36 4.99 13.90 42.36 4.0914.45 50.24 5.04 16.97 50.24 5.92 13.90 50.24 4.8514.45 54.17 5.44 16.97 54.17 6.38 13.90 54.17 5.2314.45 58.11 5.83 16.97 58.11 6.85 13.90 58.11 5.6114.45 65.98 6.62 16.97 65.98 7.78 13.90 65.98 6.3714.45 77.80 7.81 16.97 77.80 9.17 13.90 77.80 7.51
– – – – – – – – –18.39 14.80 1.89 20.91 14.80 2.15 17.83 14.80 1.8318.39 18.74 2.39 20.91 18.74 2.72 17.83 18.74 2.3218.39 22.68 2.90 20.91 22.68 3.29 17.83 22.68 2.8118.39 24.65 3.15 20.91 24.65 3.58 17.83 24.65 3.0518.39 26.61 3.40 20.91 26.61 3.86 17.83 26.61 3.3018.39 30.55 3.90 20.91 30.55 4.44 17.83 30.55 3.7818.39 34.49 4.40 20.91 34.49 5.01 17.83 34.49 4.2718.39 42.36 5.41 20.91 42.36 6.15 17.83 42.36 5.2518.39 50.24 6.41 20.91 50.24 7.29 17.83 50.24 6.2218.39 54.17 6.92 20.91 54.17 7.86 17.83 54.17 6.7118.39 58.11 7.42 20.91 58.11 8.44 17.83 58.11 7.2018.39 65.98 8.42 20.91 65.98 9.58 17.83 65.98 8.1718.39 77.80 9.93 20.91 77.80 11.29 17.83 77.80 9.64
– – – – – – – – –20.35 14.80 2.09 22.87 14.80 2.35 19.80 14.80 2.0420.35 18.74 2.65 22.87 18.74 2.98 19.80 18.74 2.5820.35 22.68 3.21 22.87 22.68 3.60 19.80 22.68 3.1220.35 24.65 3.48 22.87 24.65 3.91 19.80 24.65 3.3920.35 26.61 3.76 22.87 26.61 4.23 19.80 26.61 3.6620.35 30.55 4.32 22.87 30.55 4.85 19.80 30.55 4.2020.35 34.49 4.87 22.87 34.49 5.48 19.80 34.49 4.7420.35 42.36 5.99 22.87 42.36 6.73 19.80 42.36 5.8320.35 50.24 7.10 22.87 50.24 7.98 19.80 50.24 6.9120.35 54.17 7.66 22.87 54.17 8.61 19.80 54.17 7.4520.35 58.11 8.21 22.87 58.11 9.23 19.80 58.11 7.9920.35 65.98 9.33 22.87 65.98 10.48 19.80 65.98 9.0720.35 77.80 11.00 22.87 77.80 12.36 19.80 77.80 10.70
Egress Opening w/MaximHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
Egress Opening w/EgressHardware & Mirage Sash Locks
TRIPLE SASH
W H Area
Egress Opening w/MaximHardware & Mirage Sash Locks
TRIPLE SASH
W H Area
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A53
CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
ModelNumber
ExposedGlass Area
UnitOSM
CA1 0404 400 400 0.060 0.083 – – –CA1 0405 400 500 0.084 0.113 – – –CA1 0406 400 600 0.109 0.142 – – –CA1 0407 400 700 0.134 0.172 – – –CA1 0475 400 750 0.146 0.187 – – –CA1 0408 400 800 0.159 0.202 – – –CA1 0409 400 900 0.183 0.231 – – –CA1 0410 400 1000 0.208 0.261 – – –CA1 0412 400 1200 0.257 0.320 – – –CA1 0414 400 1400 0.307 0.380 – – –CA1 0415 400 1500 0.331 0.410 – – –CA1 0416 400 1600 0.356 0.439 – – –CA1 0418 400 1800 0.406 0.499 – – –CA1 0421 400 2100 0.480 0.588 – – –CA1 0504 500 400 0.084 0.111 345 276 0.095CA1 0505 500 500 0.119 0.150 345 376 0.130CA1 0506 500 600 0.153 0.190 345 476 0.164CA1 0507 500 700 0.188 0.230 345 576 0.199CA1 0575 500 750 0.205 0.250 345 626 0.216CA1 0508 500 800 0.223 0.270 345 676 0.233CA1 0509 500 900 0.257 0.309 345 776 0.268CA1 0510 500 1000 0.292 0.349 345 876 0.302CA1 0512 500 1200 0.362 0.428 345 1076 0.371CA1 0514 500 1400 0.431 0.508 345 1276 0.440CA1 0515 500 1500 0.466 0.547 345 1376 0.475CA1 0516 500 1600 0.500 0.587 345 1476 0.509CA1 0518 500 1800 0.570 0.667 345 1676 0.578CA1 0521 500 2100 0.674 0.786 345 1976 0.682
W H m2
VentOpening
m2
Egress Opening w/EgressHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
METRIC
CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
ModelNumber
ExposedGlass Area
UnitOSM
CA1 0804 31 1/2 15 3/4 1.69 – – – –CA1 0805 31 1/2 19 11/16 2.38 – – – –CA1 0806 31 1/2 23 5/8 3.08 3.59 25.39 18.74 3.30CA1 0807 31 1/2 27 9/16 3.77 4.34 25.39 22.68 4.00CA1 0875 31 1/2 29 1/2 4.12 4.72 25.39 24.65 4.35CA1 0808 31 1/2 31 1/2 4.47 5.09 25.39 26.61 4.69CA1 0809 31 1/2 35 7/16 5.17 5.84 25.39 30.55 5.39CA1 0810 31 1/2 39 3/8 5.86 6.59 25.39 34.49 6.08CA1 0812 31 1/2 47 1/4 7.26 8.10 25.39 42.36 7.47CA1 0814 31 1/2 55 1/8 8.65 9.60 25.39 50.24 8.86CA1 0815 31 1/2 59 1/16 9.35 10.35 25.39 54.17 9.55CA1 0816 31 1/2 63 10.04 11.10 25.39 58.11 10.25CA1 0818 31 1/2 70 7/8 11.44 12.60 25.39 65.98 11.64CA1 0821 31 1/2 82 11/16 13.52 14.85 25.39 77.80 13.72CA1 0908 35 7/16 31 1/2 5.16 5.83 29.33 26.61 5.42CA1 0909 35 7/16 35 7/16 5.97 6.68 29.33 30.55 6.22CA1 0910 35 7/16 39 3/8 6.77 7.54 29.33 34.49 7.02CA1 0912 35 7/16 47 1/4 8.38 9.26 29.33 42.36 8.63CA1 0914 35 7/16 55 1/8 9.99 10.97 29.33 50.24 10.23CA1 0915 35 7/16 59 1/16 10.79 11.83 29.33 54.17 11.03CA1 0916 35 7/16 63 11.59 12.69 29.33 58.11 11.84CA1 0918 35 7/16 70 7/8 13.20 14.40 29.33 65.98 13.44CA1 0921 35 7/16 82 11/16 15.61 16.98 29.33 77.80 15.85
W H ft2
VentOpening
ft2
Egress Opening w/EgressHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
IMPERIAL
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A54
– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – 331 276 0.091 – – –– – – 331 376 0.124 – – –– – – 331 476 0.158 – – –– – – 331 576 0.191 – – –– – – 331 626 0.207 – – –– – – 331 676 0.224 – – –– – – 331 776 0.257 – – –– – – 331 876 0.290 – – –– – – 331 1076 0.356 – – –– – – 331 1276 0.422 – – –– – – 331 1376 0.455 – – –– – – 331 1476 0.489 – – –– – – 331 1676 0.555 – – –– – – 331 1976 0.654 – – –
Egress Opening w/MaximHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
Egress Opening w/EgressHardware & Mirage Sash Locks
TRIPLE SASH
W H Area
Egress Opening w/MaximHardware & Mirage Sash Locks
TRIPLE SASH
W H Area
– – – – – – – – –– – – – – – – – –
22.32 18.74 2.91 24.84 18.74 3.23 21.77 18.74 2.8322.32 22.68 3.52 24.84 22.68 3.91 21.77 22.68 3.4322.32 24.65 3.82 24.84 24.65 4.25 21.77 24.65 3.7322.32 26.61 4.13 24.84 26.61 4.59 21.77 26.61 4.0222.32 30.55 4.74 24.84 30.55 5.27 21.77 30.55 4.6222.32 34.49 5.35 24.84 34.49 5.95 21.77 34.49 5.2122.32 42.36 6.57 24.84 42.36 7.31 21.77 42.36 6.4022.32 50.24 7.79 24.84 50.24 8.67 21.77 50.24 7.6022.32 54.17 8.40 24.84 54.17 9.35 21.77 54.17 8.1922.32 58.11 9.01 24.84 58.11 10.03 21.77 58.11 8.7922.32 65.98 10.23 24.84 65.98 11.38 21.77 65.98 9.9822.32 77.80 12.06 24.84 77.80 13.42 21.77 77.80 11.7626.26 26.61 4.85 28.78 26.61 5.32 25.71 26.61 4.7526.26 30.55 5.57 28.78 30.55 6.11 25.71 30.55 5.4526.26 34.49 6.29 28.78 34.49 6.89 25.71 34.49 6.1626.26 42.36 7.73 28.78 42.36 8.47 25.71 42.36 7.5626.26 50.24 9.16 28.78 50.24 10.04 25.71 50.24 8.9726.26 54.17 9.88 28.78 54.17 10.83 25.71 54.17 9.6726.26 58.11 10.60 28.78 58.11 11.61 25.71 58.11 10.3726.26 65.98 12.03 28.78 65.98 13.19 25.71 65.98 11.7826.26 77.80 14.19 28.78 77.80 15.55 25.71 77.80 13.89
Egress Opening w/MaximHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
Egress Opening w/EgressHardware & Mirage Sash Locks
TRIPLE SASH
W H Area
Egress Opening w/MaximHardware & Mirage Sash Locks
TRIPLE SASH
W H Area
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A55
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A56
ModelNumber
ExposedGlass Area
UnitOSM
CA1 0604 600 400 0.108 0.139 445 276 0.123CA1 0605 600 500 0.153 0.188 445 376 0.167CA1 0606 600 600 0.198 0.238 445 476 0.212CA1 0607 600 700 0.242 0.288 445 576 0.256CA1 0675 600 750 0.265 0.313 445 626 0.279CA1 0608 600 800 0.287 0.337 445 676 0.301CA1 0609 600 900 0.332 0.387 445 776 0.345CA1 0610 600 1000 0.376 0.437 445 876 0.390CA1 0612 600 1200 0.466 0.536 445 1076 0.479CA1 0614 600 1400 0.555 0.636 445 1276 0.568CA1 0615 600 1500 0.600 0.685 445 1376 0.612CA1 0616 600 1600 0.645 0.735 445 1476 0.657CA1 0618 600 1800 0.734 0.834 445 1676 0.746CA1 0621 600 2100 0.868 0.984 445 1976 0.879CA1 0704 700 400 0.132 – – – –CA1 0705 700 500 0.187 0.226 545 376 0.205CA1 0706 700 600 0.242 0.286 545 476 0.259CA1 0707 700 700 0.296 0.346 545 576 0.314CA1 0775 700 750 0.324 0.376 545 626 0.341CA1 0708 700 800 0.351 0.405 545 676 0.368CA1 0709 700 900 0.406 0.465 545 776 0.423CA1 0710 700 1000 0.461 0.525 545 876 0.477CA1 0712 700 1200 0.570 0.644 545 1076 0.586CA1 0714 700 1400 0.679 0.764 545 1276 0.695CA1 0715 700 1500 0.734 0.823 545 1376 0.750CA1 0716 700 1600 0.789 0.883 545 1476 0.804CA1 0718 700 1800 0.898 1.002 545 1676 0.913CA1 0721 700 2100 1.062 1.181 545 1976 1.077CA1 7504 750 400 0.144 – – – –CA1 7505 750 500 0.204 0.245 595 376 0.224CA1 7506 750 600 0.264 0.310 595 476 0.283CA1 7507 750 700 0.324 0.375 595 576 0.343CA1 7575 750 750 0.353 0.407 595 626 0.372CA1 7508 750 800 0.383 0.439 595 676 0.402CA1 7509 750 900 0.443 0.504 595 776 0.462CA1 7510 750 1000 0.503 0.569 595 876 0.521CA1 7512 750 1200 0.622 0.698 595 1076 0.640CA1 7514 750 1400 0.741 0.828 595 1276 0.759CA1 7515 750 1500 0.801 0.892 595 1376 0.819CA1 7516 750 1600 0.861 0.957 595 1476 0.878CA1 7518 750 1800 0.980 1.086 595 1676 0.997CA1 7521 750 2100 1.159 1.280 595 1976 1.176CA1 0804 800 400 0.157 – – – –CA1 0805 800 500 0.221 – – – –CA1 0806 800 600 0.286 0.334 645 476 0.307CA1 0807 800 700 0.351 0.404 645 576 0.372CA1 0875 800 750 0.383 0.438 645 626 0.404CA1 0808 800 800 0.415 0.473 645 676 0.436CA1 0809 800 900 0.480 0.543 645 776 0.501CA1 0810 800 1000 0.545 0.613 645 876 0.565CA1 0812 800 1200 0.674 0.752 645 1076 0.694CA1 0814 800 1400 0.804 0.891 645 1276 0.823CA1 0815 800 1500 0.868 0.961 645 1376 0.888CA1 0816 800 1600 0.933 1.031 645 1476 0.952CA1 0818 800 1800 1.062 1.170 645 1676 1.081CA1 0821 800 2100 1.256 1.379 645 1976 1.275CA1 0904 900 400 0.181 – – – –CA1 0905 900 500 0.255 – – – –CA1 0906 900 600 0.330 – – – –CA1 0907 900 700 0.405 – – – –CA1 0975 900 750 0.442 – – – –CA1 0908 900 800 0.480 0.541 745 676 0.504CA1 0909 900 900 0.554 0.621 745 776 0.578CA1 0910 900 1000 0.629 0.701 745 876 0.653CA1 0912 900 1200 0.778 0.860 745 1076 0.802CA1 0914 900 1400 0.928 1.019 745 1276 0.951CA1 0915 900 1500 1.002 1.099 745 1376 1.025CA1 0916 900 1600 1.077 1.179 745 1476 1.100CA1 0918 900 1800 1.227 1.338 745 1676 1.249CA1 0921 900 2100 1.451 1.577 745 1976 1.472
W H m2
VentOpening
m2
Egress Opening w/EgressHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
METRIC
CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A57
367 276 0.101 431 276 0.119 353 276 0.097367 376 0.138 431 376 0.162 353 376 0.133367 476 0.175 431 476 0.205 353 476 0.168367 576 0.211 431 576 0.248 353 576 0.203367 626 0.230 431 626 0.270 353 626 0.221367 676 0.248 431 676 0.291 353 676 0.239367 776 0.285 431 776 0.334 353 776 0.274367 876 0.321 431 876 0.378 353 876 0.309367 1076 0.395 431 1076 0.464 353 1076 0.380367 1276 0.468 431 1276 0.550 353 1276 0.450367 1376 0.505 431 1376 0.593 353 1376 0.486367 1476 0.542 431 1476 0.636 353 1476 0.521367 1676 0.615 431 1676 0.722 353 1676 0.592367 1976 0.725 431 1976 0.852 353 1976 0.698
– – – – – – – – –467 376 0.176 531 376 0.200 453 376 0.170467 476 0.222 531 476 0.253 453 476 0.216467 576 0.269 531 576 0.306 453 576 0.261467 626 0.292 531 626 0.332 453 626 0.284467 676 0.316 531 676 0.359 453 676 0.306467 776 0.362 531 776 0.412 453 776 0.352467 876 0.409 531 876 0.465 453 876 0.397467 1076 0.502 531 1076 0.571 453 1076 0.487467 1276 0.596 531 1276 0.678 453 1276 0.578467 1376 0.643 531 1376 0.731 453 1376 0.623467 1476 0.689 531 1476 0.784 453 1476 0.669467 1676 0.783 531 1676 0.890 453 1676 0.759467 1976 0.923 531 1976 1.049 453 1976 0.895
– – – – – – – – –517 376 0.194 581 376 0.218 503 376 0.189517 476 0.246 581 476 0.277 503 476 0.239517 576 0.298 581 576 0.335 503 576 0.290517 626 0.324 581 626 0.364 503 626 0.315517 676 0.349 581 676 0.393 503 676 0.340517 776 0.401 581 776 0.451 503 776 0.390517 876 0.453 581 876 0.509 503 876 0.441517 1076 0.556 581 1076 0.625 503 1076 0.541517 1276 0.660 581 1276 0.741 503 1276 0.642517 1376 0.711 581 1376 0.799 503 1376 0.692517 1476 0.763 581 1476 0.858 503 1476 0.742517 1676 0.866 581 1676 0.974 503 1676 0.843517 1976 1.022 581 1976 1.148 503 1976 0.994
– – – – – – – – –– – – – – – – – –
567 476 0.270 631 476 0.300 553 476 0.263567 576 0.327 631 576 0.363 553 576 0.319567 626 0.355 631 626 0.395 553 626 0.346567 676 0.383 631 676 0.427 553 676 0.374567 776 0.440 631 776 0.490 553 776 0.429567 876 0.497 631 876 0.553 553 876 0.484567 1076 0.610 631 1076 0.679 553 1076 0.595567 1276 0.723 631 1276 0.805 553 1276 0.706567 1376 0.780 631 1376 0.868 553 1376 0.761567 1476 0.837 631 1476 0.931 553 1476 0.816567 1676 0.950 631 1676 1.058 553 1676 0.927567 1976 1.120 631 1976 1.247 553 1976 1.093
– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –– – – – – – – – –
667 676 0.451 731 676 0.494 653 676 0.441667 776 0.518 731 776 0.567 653 776 0.507667 876 0.584 731 876 0.640 653 876 0.572667 1076 0.718 731 1076 0.787 653 1076 0.703667 1276 0.851 731 1276 0.933 653 1276 0.833667 1376 0.918 731 1376 1.006 653 1376 0.899667 1476 0.984 731 1476 1.079 653 1476 0.964667 1676 1.118 731 1676 1.225 653 1676 1.094667 1976 1.318 731 1976 1.444 653 1976 1.290
Egress Opening w/MaximHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
Egress Opening w/EgressHardware & Mirage Sash Locks
TRIPLE SASH
W H Area
Egress Opening w/MaximHardware & Mirage Sash Locks
TRIPLE SASH
W H Area
FIXED CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
ModelNumber
ExposedGlass Area
UnitOSM
CA1 0404 15 3/4 15 3/4 0.64CA1 0405 15 3/4 19 11/16 0.91CA1 0406 15 3/4 23 5/8 1.18CA1 0408 15 3/4 31 1/2 1.71CA1 0409 15 3/4 35 7/16 1.97CA1 0410 15 3/4 39 3/8 2.24CA1 0412 15 3/4 47 1/4 2.77CA1 0414 15 3/4 55 1/8 3.30CA1 0415 15 3/4 59 1/16 3.57CA1 0416 15 3/4 63 3.83CA1 0418 15 3/4 70 7/8 4.37CA1 0421 15 3/4 82 11/16 5.16CA1 0424 15 3/4 94 1/2 5.96CA1 0504 19 2/3 15 3/4 0.90CA1 0505 19 2/3 19 11/16 1.28CA1 0506 19 2/3 23 5/8 1.65CA1 0508 19 2/3 31 1/2 2.40CA1 0509 19 2/3 35 7/16 2.77CA1 0510 19 2/3 39 3/8 3.14CA1 0512 19 2/3 47 1/4 3.89CA1 0514 19 2/3 55 1/8 4.64CA1 0515 19 2/3 59 1/16 5.01CA1 0516 19 2/3 63 5.39CA1 0518 19 2/3 70 7/8 6.13CA1 0521 19 2/3 82 11/16 7.25CA1 0524 19 2/3 94 1/2 8.37CA1 0604 23 5/8 15 3/4 1.16CA1 0605 23 5/8 19 11/16 1.65CA1 0606 23 5/8 23 5/8 2.13CA1 0608 23 5/8 31 1/2 3.09CA1 0609 23 5/8 35 7/16 3.57CA1 0610 23 5/8 39 3/8 4.05CA1 0612 23 5/8 47 1/4 5.01CA1 0614 23 5/8 55 1/8 5.98CA1 0615 23 5/8 59 1/16 6.46CA1 0616 23 5/8 63 6.94CA1 0618 23 5/8 70 7/8 7.90CA1 0621 23 5/8 82 11/16 9.34CA1 0624 23 5/8 94 1/2 10.79
W H ft2
IMPERIAL
ModelNumber
ExposedGlass Area
UnitOSM
CA1 0404 400 400 0.060CA1 0405 400 500 0.084CA1 0406 400 600 0.109CA1 0408 400 800 0.159CA1 0409 400 900 0.183CA1 0410 400 1000 0.208CA1 0412 400 1200 0.257CA1 0414 400 1400 0.307CA1 0415 400 1500 0.331CA1 0416 400 1600 0.356CA1 0418 400 1800 0.406CA1 0421 400 2100 0.480CA1 0424 400 2400 0.554CA1 0504 500 400 0.084CA1 0505 500 500 0.119CA1 0506 500 600 0.153CA1 0508 500 800 0.223CA1 0509 500 900 0.257CA1 0510 500 1000 0.292CA1 0512 500 1200 0.362CA1 0514 500 1400 0.431CA1 0515 500 1500 0.466CA1 0516 500 1600 0.500CA1 0518 500 1800 0.570CA1 0521 500 2100 0.674CA1 0524 500 2400 0.778CA1 0604 600 400 0.108CA1 0605 600 500 0.153CA1 0606 600 600 0.198CA1 0608 600 800 0.287CA1 0609 600 900 0.332CA1 0610 600 1000 0.376CA1 0612 600 1200 0.466CA1 0614 600 1400 0.555CA1 0615 600 1500 0.600CA1 0616 600 1600 0.645CA1 0618 600 1800 0.734CA1 0621 600 2100 0.868CA1 0624 600 2400 1.002
W H m2
METRIC
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A58
FIXED CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
ModelNumber
ExposedGlass Area
UnitOSM
W H ft2
IMPERIAL
ModelNumber
ExposedGlass Area
UnitOSM
W H m2
METRIC
CA1 0704 700 400 0.132CA1 0705 700 500 0.187CA1 0706 700 600 0.242CA1 0708 700 800 0.351CA1 0709 700 900 0.406CA1 0710 700 1000 0.461CA1 0712 700 1200 0.570CA1 0714 700 1400 0.679CA1 0715 700 1500 0.734CA1 0716 700 1600 0.789CA1 0718 700 1800 0.898CA1 0721 700 2100 1.062CA1 0724 700 2400 1.226CA1 7504 750 400 0.144CA1 7505 750 500 0.204CA1 7506 750 600 20.264CA1 7508 750 800 0.383CA1 7509 750 900 0.443CA1 7510 750 1000 0.503CA1 7512 750 1200 0.622CA1 7514 750 1400 0.741CA1 7515 750 1500 0.801CA1 7516 750 1600 0.861CA1 7518 750 1800 0.980CA1 7521 750 2100 1.159CA1 7524 750 2400 1.338CA1 0804 800 400 0.157CA1 0805 800 500 0.221CA1 0806 800 600 0.286CA1 0808 800 800 0.415CA1 0809 800 900 0.480CA1 0810 800 1000 0.545CA1 0812 800 1200 0.674CA1 0814 800 1400 0.804CA1 0815 800 1500 0.868CA1 0816 800 1600 0.933CA1 0818 800 1800 1.062CA1 0821 800 2100 1.256CA1 0824 800 2400 1.451
CA1 0704 27 5/9 15 3/4 1.42CA1 0705 27 5/9 19 11/16 2.01CA1 0706 27 5/9 23 5/8 2.60CA1 0708 27 5/9 31 1/2 3.78CA1 0709 27 5/9 35 7/16 4.37CA1 0710 27 5/9 39 3/8 4.96CA1 0712 27 5/9 47 1/4 6.14CA1 0714 27 5/9 55 1/8 7.31CA1 0715 27 5/9 59 1/16 7.90CA1 0716 27 5/9 63 8.49CA1 0718 27 5/9 70 7/8 9.67CA1 0721 27 5/9 82 11/16 11.43CA1 0724 27 5/9 94 1/2 13.20CA1 7504 29 1/2 15 3/4 1.56CA1 7505 29 1/2 19 11/16 2.20CA1 7506 29 1/2 23 5/8 2.84CA1 7508 29 1/2 31 1/2 4.13CA1 7509 29 1/2 35 7/16 4.77CA1 7510 29 1/2 39 3/8 5.41CA1 7512 29 1/2 47 1/4 6.70CA1 7514 29 1/2 55 1/8 7.98CA1 7515 29 1/2 59 1/16 8.62CA1 7516 29 1/2 63 9.27CA1 7518 29 1/2 70 7/8 10.55CA1 7521 29 1/2 82 11/16 12.48CA1 7524 29 1/2 94 1/2 14.41CA1 0804 31 1/2 15 3/4 1.69CA1 0805 31 1/2 19 11/16 2.38CA1 0806 31 1/2 23 5/8 3.08CA1 0808 31 1/2 31 1/2 4.47CA1 0809 31 1/2 35 7/16 5.17CA1 0810 31 1/2 39 3/8 5.86CA1 0812 31 1/2 47 1/4 7.26CA1 0814 31 1/2 55 1/8 8.65CA1 0815 31 1/2 59 1/16 9.35CA1 0816 31 1/2 63 10.04CA1 0818 31 1/2 70 7/8 11.44CA1 0821 31 1/2 82 11/16 13.52CA1 0824 31 1/2 94 1/2 15.61
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A59
FIXED CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
ModelNumber
ExposedGlass Area
UnitOSM
W H ft2
IMPERIAL
ModelNumber
ExposedGlass Area
UnitOSM
W H m2
METRIC
CA1 0904 900 400 0.181CA1 0905 900 500 0.255CA1 0906 900 600 0.330CA1 0908 900 800 0.480CA1 0909 900 900 0.554CA1 0910 900 1000 0.629CA1 0912 900 1200 0.778CA1 0914 900 1400 0.928CA1 0915 900 1500 1.002CA1 0916 900 1600 1.077CA1 0918 900 1800 1.227CA1 0921 900 2100 1.451CA1 0924 900 2400 1.675CA1 1004 1000 400 0.205CA1 1005 1000 500 0.290CA1 1006 1000 600 0.374CA1 1008 1000 800 0.544CA1 1009 1000 900 0.628CA1 1010 1000 1000 0.713CA1 1012 1000 1200 0.883CA1 1014 1000 1400 1.052CA1 1015 1000 1500 1.137CA1 1016 1000 1600 1.221CA1 1018 1000 1800 1.391CA1 1021 1000 2100 1.645CA1 1024 1000 2400 1.899CA1 1204 1200 400 0.253CA1 1205 1200 500 0.358CA1 1206 1200 600 0.463CA1 1208 1200 800 0.672CA1 1209 1200 900 0.777CA1 1210 1200 1000 0.882CA1 1212 1200 1200 1.091CA1 1214 1200 1400 1.300CA1 1215 1200 1500 1.405CA1 1216 1200 1600 1.510CA1 1218 1200 1800 1.719CA1 1221 1200 2100 2.033CA1 1224 1200 2400 2.347CA1 1404 1400 400 0.302CA1 1405 1400 500 0.426CA1 1406 1400 600 0.551CA1 1408 1400 800 0.801CA1 1409 1400 900 0.925CA1 1410 1400 1000 1.050CA1 1412 1400 1200 1.299CA1 1414 1400 1400 1.549CA1 1415 1400 1500 1.673CA1 1416 1400 1600 1.798CA1 1418 1400 1800 2.048CA1 1421 1400 2100 2.422CA1 1424 1400 2400 2.796
CA1 0904 35 3/7 15 3/4 1.95CA1 0905 35 3/7 19 11/16 2.75CA1 0906 35 3/7 23 5/8 3.55CA1 0908 35 3/7 31 1/2 5.16CA1 0909 35 3/7 35 7/16 5.97CA1 0910 35 3/7 39 3/8 6.77CA1 0912 35 3/7 47 1/4 8.38CA1 0914 35 3/7 55 1/8 9.99CA1 0915 35 3/7 59 1/16 10.79CA1 0916 35 3/7 63 11.59CA1 0918 35 3/7 70 7/8 13.20CA1 0921 35 3/7 82 11/16 15.61CA1 0924 35 3/7 94 1/2 18.03CA1 1004 39 3/8 15 3/4 2.21CA1 1005 39 3/8 19 11/16 3.12CA1 1006 39 3/8 23 5/8 4.03CA1 1008 39 3/8 31 1/2 5.85CA1 1009 39 3/8 35 7/16 6.76CA1 1010 39 3/8 39 3/8 7.68CA1 1012 39 3/8 47 1/4 9.50CA1 1014 39 3/8 55 1/8 11.32CA1 1015 39 3/8 59 1/16 12.24CA1 1016 39 3/8 63 13.15CA1 1018 39 3/8 70 7/8 14.97CA1 1021 39 3/8 82 11/16 17.71CA1 1024 39 3/8 94 1/2 20.44CA1 1204 47 1/4 15 3/4 2.73CA1 1205 47 1/4 19 11/16 3.85CA1 1206 47 1/4 23 5/8 4.98CA1 1208 47 1/4 31 1/2 7.24CA1 1209 47 1/4 35 7/16 8.36CA1 1210 47 1/4 39 3/8 9.49CA1 1212 47 1/4 47 1/4 11.74CA1 1214 47 1/4 55 1/8 14.00CA1 1215 47 1/4 59 1/16 15.12CA1 1216 47 1/4 63 16.25CA1 1218 47 1/4 70 7/8 18.51CA1 1221 47 1/4 82 11/16 21.89CA1 1224 47 1/4 94 1/2 25.27CA1 1404 55 1/8 15 3/4 3.25CA1 1405 55 1/8 19 11/16 4.59CA1 1406 55 1/8 23 5/8 5.93CA1 1408 55 1/8 31 1/2 8.62CA1 1409 55 1/8 35 7/16 9.96CA1 1410 55 1/8 39 3/8 11.30CA1 1412 55 1/8 47 1/4 13.99CA1 1414 55 1/8 55 1/8 16.67CA1 1415 55 1/8 59 1/16 18.01CA1 1416 55 1/8 63 19.36CA1 1418 55 1/8 70 7/8 22.04CA1 1421 55 1/8 82 11/16 26.07CA1 1424 55 1/8 94 1/2 30.09
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A60
FIXED CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
ModelNumber
ExposedGlass Area
UnitOSM
W H ft2
IMPERIAL
ModelNumber
ExposedGlass Area
UnitOSM
W H m2
METRIC
CA1 1504 1500 400 0.326CA1 1505 1500 500 0.461CA1 1506 1500 600 0.595CA1 1508 1500 800 0.865CA1 1509 1500 900 0.999CA1 1510 1500 1000 1.134CA1 1512 1500 1200 1.404CA1 1514 1500 1400 1.673CA1 1515 1500 1500 1.808CA1 1516 1500 1600 1.942CA1 1518 1500 1800 2.212CA1 1521 1500 2100 2.616CA1 1524 1500 2400 3.020CA1 1604 1600 400 0.350CA1 1605 1600 500 0.495CA1 1606 1600 600 0.640CA1 1608 1600 800 0.929CA1 1609 1600 900 1.074CA1 1610 1600 1000 1.218CA1 1612 1600 1200 1.508CA1 1614 1600 1400 1.797CA1 1615 1600 1500 1.942CA1 1616 1600 1600 2.087CA1 1618 1600 1800 2.376CA1 1621 1600 2100 2.810CA1 1624 1600 2400 3.244CA1 1804 1800 400 0.399CA1 1805 1800 500 0.563CA1 1806 1800 600 0.728CA1 1808 1800 800 1.057CA1 1809 1800 900 1.222CA1 1810 1800 1000 1.387CA1 1812 1800 1200 1.716CA1 1814 1800 1400 2.046CA1 1815 1800 1500 2.210CA1 1816 1800 1600 2.375CA1 1818 1800 1800 2.704CA1 1821 1800 2100 3.198CA1 1824 1800 2400 3.693
CA1 1504 59 15 3/4 3.51CA1 1505 59 19 11/16 4.96CA1 1506 59 23 5/8 6.41CA1 1508 59 31 1/2 9.31CA1 1509 59 35 7/16 10.76CA1 1510 59 39 3/8 12.21CA1 1512 59 47 1/4 15.11CA1 1514 59 55 1/8 18.01CA1 1515 59 59 1/16 19.46CA1 1516 59 63 20.91CA1 1518 59 70 7/8 23.81CA1 1521 59 82 11/16 28.16CA1 1524 59 94 1/2 32.51CA1 1604 63 15 3/4 3.77CA1 1605 63 19 11/16 5.33CA1 1606 63 23 5/8 6.88CA1 1608 63 31 1/2 10.00CA1 1609 63 35 7/16 11.56CA1 1610 63 39 3/8 13.11CA1 1612 63 47 1/4 16.23CA1 1614 63 55 1/8 19.34CA1 1615 63 59 1/16 20.90CA1 1616 63 63 22.46CA1 1618 63 70 7/8 25.57CA1 1621 63 82 11/16 30.25CA1 1624 63 94 1/2 34.92CA1 1804 70 7/8 15 3/4 4.29CA1 1805 70 7/8 19 11/16 6.06CA1 1806 70 7/8 23 5/8 7.84CA1 1808 70 7/8 31 1/2 11.38CA1 1809 70 7/8 35 7/16 13.15CA1 1810 70 7/8 39 3/8 14.93CA1 1812 70 7/8 47 1/4 18.47CA1 1814 70 7/8 55 1/8 22.02CA1 1815 70 7/8 59 1/16 23.79CA1 1816 70 7/8 63 25.56CA1 1818 70 7/8 70 7/8 29.11CA1 1821 70 7/8 82 11/16 34.43CA1 1824 70 7/8 94 1/2 39.75
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A61
FRENCH CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
ModelNumber
ExposedGlass Area
UnitOSM
FCA 1008 39 3/8 31 1/2 2.54 6.56FCA 1009 39 3/8 35 7/16 2.94 7.52FCA 1010 39 3/8 39 3/8 3.33 8.49FCA 1012 39 3/8 47 1/4 4.12 10.42FCA 1014 39 3/8 55 1/8 4.91 12.35FCA 1015 39 3/8 59 5.31 13.31FCA 1016 39 3/8 63 5.70 14.28FCA 1018 39 3/8 70 3/4 6.50 16.21FCA 1208 47 1/4 31 1/2 3.23 8.02FCA 1209 47 1/4 35 7/16 3.73 9.20FCA 1210 47 1/4 39 3/8 4.24 10.38FCA 1212 47 1/4 47 1/4 5.24 12.74FCA 1214 47 1/4 55 1/8 6.25 15.10FCA 1215 47 1/4 59 6.75 16.28FCA 1216 47 1/4 63 7.26 17.46FCA 1218 47 1/4 70 3/4 8.26 19.83FCA 1408 55 1/8 311/2 3.92 9.48FCA 1409 55 1/8 35 7/16 4.53 10.88FCA 1410 55 1/8 39 3/8 5.14 12.27FCA 1412 55 1/8 47 1/4 6.37 15.06FCA 1414 55 1/8 55 1/8 7.59 17.86FCA 1415 55 1/8 59 8.20 19.25FCA 1416 55 1/8 63 8.81 20.65FCA 1418 55 1/8 70 3/4 10.03 23.44FCA 1508 59 1/16 31 1/2 4.27 10.21FCA 1509 59 1/16 35 7/16 4.93 11.71FCA 1510 59 1/16 39 3/8 5.60 13.22FCA 1512 59 1/16 47 1/4 6.93 16.23FCA 1514 59 1/16 55 1/8 8.26 19.23FCA 1515 59 1/16 59 8.92 20.74FCA 1516 59 1/16 63 9.58 22.24FCA 1518 59 1/16 70 3/4 10.91 25.25FCA 1608 63 31 1/2 4.61 10.94FCA 1609 63 35 7/16 5.33 12.55FCA 1610 63 39 3/8 6.05 14.16FCA 1612 63 47 1/4 7.49 17.39FCA 1614 63 55 1/8 8.92 20.61FCA 1615 63 59 9.64 22.22FCA 1616 63 63 10.36 23.83FCA 1618 63 70 3/4 11.80 27.05FCA 1808 70 3/4 31 1/2 5.30 12.40FCA 1809 70 3/4 35 7/16 6.13 14.23FCA 1810 70 3/4 39 3/8 6.96 16.06FCA 1812 70 3/4 47 1/4 8.61 19.71FCA 1814 70 3/4 55 1/8 10.26 23.36FCA 1815 70 3/4 59 11.09 25.19FCA 1816 70 3/4 63 11.91 27.02FCA 1818 70 3/4 70 3/4 13.57 30.67
W H ft2
VentOpening
ft2
IMPERIAL
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A62
30.98 26.61 5.73 22.40 26.61 4.1430.98 30.55 6.57 22.40 30.55 4.7530.98 34.49 7.42 22.40 34.49 5.3730.98 42.36 9.12 22.40 42.36 6.5930.98 50.24 10.81 22.40 50.24 7.8230.98 54.17 11.66 22.40 54.17 8.4330.98 58.11 12.50 22.40 58.11 9.0430.98 65.98 14.20 22.40 65.98 10.2638.86 26.61 7.18 30.28 26.61 5.6038.86 30.55 8.24 30.28 30.55 6.4238.86 34.49 9.31 30.28 34.49 7.2538.86 42.36 11.43 30.28 42.36 8.9138.86 50.24 13.56 30.28 50.24 10.5638.86 54.17 14.62 30.28 54.17 11.3938.86 58.11 15.68 30.28 58.11 12.2238.86 65.98 17.81 30.28 65.98 13.8746.73 26.61 8.64 38.15 26.61 7.0546.73 30.55 9.91 38.15 30.55 8.0946.73 34.49 11.19 38.15 34.49 9.1446.73 42.36 13.75 38.15 42.36 11.2246.73 50.24 16.30 38.15 50.24 13.3146.73 54.17 17.58 38.15 54.17 14.3546.73 58.11 18.86 38.15 58.11 15.4046.73 65.98 21.41 38.15 65.98 17.4850.67 26.61 9.36 42.09 26.61 7.7850.67 30.55 10.75 42.09 30.55 8.9350.67 34.49 12.14 42.09 34.49 10.0850.67 42.36 14.91 42.09 42.36 12.3850.67 50.24 17.68 42.09 50.24 14.6850.67 54.17 19.06 42.09 54.17 15.8350.67 58.11 20.45 42.09 58.11 16.9850.67 65.98 23.22 42.09 65.98 19.2954.61 26.61 10.09 46.02 26.61 8.5154.61 30.55 11.59 46.02 30.55 9.7654.61 34.49 13.08 46.02 34.49 11.0254.61 42.36 16.06 46.02 42.36 13.5454.61 50.24 19.05 46.02 50.24 16.0654.61 54.17 20.54 46.02 54.17 17.3154.61 58.11 22.04 46.02 58.11 18.5754.61 65.98 25.02 46.02 65.98 21.0962.48 26.61 11.55 53.90 26.61 9.9662.48 30.55 13.26 53.90 30.55 11.4362.48 34.49 14.96 53.90 34.49 12.9162.48 42.36 18.38 53.90 42.36 15.8662.48 50.24 21.80 53.90 50.24 18.8062.48 54.17 23.51 53.90 54.17 20.2862.48 58.11 25.21 53.90 58.11 21.7562.48 65.98 28.63 53.90 65.98 24.70
Egress Opening w/MaximHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
Egress Opening w/EgressHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A63
ModelNumber
ExposedGlass Area
UnitOSM
FCA 1008 1000 800 0.236 0.609FCA 1009 1000 900 0.273 0.699FCA 1010 1000 1000 0.309 0.788FCA 1012 1000 1200 0.383 0.968FCA 1014 1000 1400 0.456 1.147FCA 1015 1000 1500 0.493 1.237FCA 1016 1000 1600 0.530 1.327FCA 1018 1000 1800 0.603 1.506FCA 1208 1200 800 0.300 0.745FCA 1209 1200 900 0.347 0.855FCA 1210 1200 1000 0.394 0.964FCA 1212 1200 1200 0.487 1.184FCA 1214 1200 1400 0.581 1.403FCA 1215 1200 1500 0.627 1.513FCA 1216 1200 1600 0.674 1.622FCA 1218 1200 1800 0.768 1.842FCA 1408 1400 800 0.364 0.881FCA 1409 1400 900 0.421 1.010FCA 1410 1400 1000 0.478 1.140FCA 1412 1400 1200 0.591 1.399FCA 1414 1400 1400 0.705 1.659FCA 1415 1400 1500 0.762 1.789FCA 1416 1400 1600 0.818 1.918FCA 1418 1400 1800 0.932 2.178FCA 1508 1500 800 0.396 0.949FCA 1509 1500 900 0.458 1.088FCA 1510 1500 1000 0.520 1.228FCA 1512 1500 1200 0.643 1.507FCA 1514 1500 1400 0.767 1.787FCA 1515 1500 1500 0.829 1.926FCA 1516 1500 1600 0.890 2.066FCA 1518 1500 1800 1.014 2.346FCA 1608 1600 800 0.429 1.016FCA 1609 1600 900 0.495 1.166FCA 1610 1600 1000 0.562 1.316FCA 1612 1600 1200 0.696 1.615FCA 1614 1600 1400 0.829 1.915FCA 1615 1600 1500 0.896 2.064FCA 1616 1600 1600 0.963 2.214FCA 1618 1600 1800 1.096 2.513FCA 1808 1800 800 0.493 1.152FCA 1809 1800 900 0.569 1.322FCA 1810 1800 1000 0.646 1.492FCA 1812 1800 1200 0.800 1.831FCA 1814 1800 1400 0.953 2.170FCA 1815 1800 1500 1.030 2.340FCA 1816 1800 1600 1.107 2.510FCA 1818 1800 1800 1.260 2.849
W H m2
VentOpening
m2
METRIC
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A64
FRENCH CASEMENT WINDOW – LIGHT AND VENT SCHEDULE
787 676 0.532 569 676 0.385787 776 0.611 569 776 0.442787 876 0.689 569 876 0.498787 1076 0.847 569 1076 0.612787 1276 1.004 569 1276 0.726787 1376 1.083 569 1376 0.783787 1476 1.162 569 1476 0.840787 1676 1.319 569 1676 0.954987 676 0.667 769 676 0.520987 776 0.766 769 776 0.597987 876 0.865 769 876 0.674987 1076 1.062 769 1076 0.827987 1276 1.259 769 1276 0.981987 1376 1.358 769 1376 1.058987 1476 1.457 769 1476 1.135987 1676 1.654 769 1676 1.289
1187 676 0.802 969 676 0.6551187 776 0.921 969 776 0.7521187 876 1.040 969 876 0.8491187 1076 1.277 969 1076 1.0431187 1276 1.515 969 1276 1.2361187 1376 1.633 969 1376 1.3331187 1476 1.752 969 1476 1.4301187 1676 1.989 969 1676 1.6241287 676 0.870 1069 676 0.7231287 776 0.999 1069 776 0.8301287 876 1.127 1069 876 0.9361287 1076 1.385 1069 1076 1.1501287 1276 1.642 1069 1276 1.3641287 1376 1.771 1069 1376 1.4711287 1476 1.900 1069 1476 1.5781287 1676 2.157 1069 1676 1.7921387 676 0.938 1169 676 0.7901387 776 1.076 1169 776 0.9071387 876 1.215 1169 876 1.0241387 1076 1.492 1169 1076 1.2581387 1276 1.770 1169 1276 1.4921387 1376 1.909 1169 1376 1.6091387 1476 2.047 1169 1476 1.7251387 1676 2.325 1169 1676 1.9591587 676 1.073 1369 676 0.9251587 776 1.232 1369 776 1.0621587 876 1.390 1369 876 1.1991587 1076 1.708 1369 1076 1.4731587 1276 2.025 1369 1276 1.7471587 1376 2.184 1369 1376 1.8841587 1476 2.342 1369 1476 2.0211587 1676 2.660 1369 1676 2.294
Egress Opening w/MaximHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
Egress Opening w/EgressHardware & Mirage Sash Locks
DOUBLE SASH
W H Area
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A65
Unit Height Max Opening
PCA EGRESS OPENINGS (ft2)DOUBLE SASH, DSM16CASP HINGE
Unit Width 31 9/16"
PCA EGRESS – DOUBLE SASH, HP1 GLAZING & DS16CASP HINGE
1.643 1.968
23 5/8" 1.614 2.653 3.17831 1/2" 2.270 3.732 4.469
35 7/16" 2.598 4.271 5.11539 3/8" 2.926 4.810 5.76147 1/4" 3.582 5.889 7.05355 1/8" 4.238 6.967 8.344
59 1/16" 4.566 7.507 8.99063" 4.894 8.046 9.636
70 7/8" 5.550 9.125 10.92882 11/16" 6.534 10.742 –
35 7/16"
Unit Height Max Opening
Unit Width 801
0.501 0.600
600 0.492 0.246 0.295800 0.692 0.347 0.415900 0.792 0.397 0.475
1000 0.892 0.447 0.5351200 1.092 0.547 0.6551400 1.292 0.647 0.7751500 1.392 0.697 0.8351600 1.492 0.747 0.8951800 1.692 0.848 1.0152100 1.992 0.998 –
900
PCA EGRESS OPENINGS (m2)DOUBLE SASH, DSM16CASP HINGE
Unit Height Max Opening
PCA EGRESS OPENINGS (ft2)DOUBLE SASH, DSE16 HINGE
Unit Width 25 5/8" 27 9/16" 29 1/2"
PCA EGRESS – DOUBLE SASH, HP1 GLAZING & DSE16 HINGE
1.699 1.863 2.027 2.191
23 5/8" 1.614 2.743 3.008 3.273 3.53831 1/2" 2.270 3.858 4.231 4.603 4.976
35 7/16" 2.598 4.416 4.842 5.269 5.69539 3/8" 2.926 4.974 5.454 5.934 6.41447 1/4" 3.582 6.089 6.676 7.264 7.85255 1/8" 4.238 7.204 7.899 8.595 9.290
59 1/16" 4.566 7.761 8.511 9.260 10.00963" 4.894 8.319 9.122 9.925 10.728
70 7/8" 5.550 9.434 10.345 11.255 12.16682 11/16" 6.534 11.107 12.179 – –
31 1/2"
Unit Height Max Opening
PCA EGRESS OPENINGS (m2)DOUBLE SASH, DSE16 HINGE
Unit Width 650 700 750
0.518 0.568 0.618 0.668
600 0.492 0.255 0.279 0.304 0.329800 0.692 0.358 0.393 0.428 0.462900 0.792 0.410 0.450 0.489 0.529
1000 0.892 0.462 0.507 0.551 0.5961200 1.092 0.566 0.620 0.675 0.7291400 1.292 0.669 0.734 0.798 0.8631500 1.392 0.721 0.791 0.860 0.9301600 1.492 0.773 0.847 0.922 0.9971800 1.692 0.876 0.961 1.046 1.1302100 1.992 1.032 1.131 – –
800
PUSH OUT CASEMENT WINDOW – EGRESS OPENING SCHEDULE
Unit Height Max Opening
PCA EGRESS OPENINGS (ft2)DOUBLE SASH, DSE12 HINGE
Unit Width 15 3/4" 19 11/16" 23 5/8"
PCA EGRESS – DOUBLE SASH, HP1 GLAZING & DSE12 HINGE
0.879 1.207 1.535 1.696
23 5/8" 1.614 1.419 1.949 2.478 2.73831 1/2" 2.270 1.996 2.741 3.486 3.851
35 7/16" 2.598 2.285 3.137 3.990 4.40739 3/8" 2.926 2.573 3.533 4.493 4.96447 1/4" 3.582 3.150 4.326 5.501 6.07755 1/8" 4.238 3.727 5.118 6.509 7.190
59 1/16" 4.566 4.016 5.514 7.012 7.74663" 4.894 4.304 5.910 7.516 8.303
70 7/8" 5.550 4.881 6.702 8.524 9.41682 11/16" 6.534 5.746 7.891 10.035 11.085
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A66
25 9/16"
Unit Height Max Opening
PCA EGRESS OPENINGS (m2)DOUBLE SASH, DSE12 HINGE
Unit Width 400 500 600
0.268 0.368 0.468 0.517
600 0.492 0.132 0.181 0.230 0.254800 0.692 0.185 0.255 0.324 0.358900 0.792 0.212 0.291 0.371 0.409
1000 0.892 0.239 0.328 0.417 0.4611200 1.092 0.293 0.402 0.511 0.5651400 1.292 0.346 0.475 0.605 0.6681500 1.392 0.373 0.512 0.651 0.7201600 1.492 0.400 0.549 0.698 0.7711800 1.692 0.453 0.623 0.792 0.8752100 1.992 0.534 0.733 0.932 1.030
649Imperial Metric
Imperial Metric
Imperial Metric
Unit Height Max Opening
PCA EGRESS OPENINGS (ft2)TRIPLE SASH, DSM16CASP HINGE
Unit Width 31 9/16"
PCA EGRESS – TRIPLE SASH, HP2 OR HP3 GLAZING & DS16CASP HINGE
1.597 1.922
23 5/8" 1.614 2.579 3.10331 1/2" 2.270 3.628 4.365
35 7/16" 2.598 4.152 4.99639 3/8" 2.926 4.676 5.62647 1/4" 3.582 5.724 6.88855 1/8" 4.238 – –
59 1/16" 4.566 – –63" 4.894 – –
70 7/8" 5.550 – –82 11/16" 6.534 – –
35 7/16"
Unit Height Max Opening
Unit Width 801
0.487 0.586
600 0.492 0.240 0.288800 0.692 0.337 0.406900 0.792 0.386 0.464
1000 0.892 0.434 0.5231200 1.092 0.532 0.6401400 1.292 – –1500 1.392 – –1600 1.492 – –1800 1.692 – –2100 1.992 – –
900
PCA EGRESS OPENINGS (m2)TRIPLE SASH, DSM16CASP HINGE
Unit Height Max Opening
PCA EGRESS OPENINGS (ft2)TRIPLE SASH, DSE16 HINGE
Unit Width 25 5/8" 27 9/16" 29 1/2"
PCA EGRESS – TRIPLE SASH, HP2 OR HP3 GLAZING & DSE16 HINGE
1.653 1.817 1.981 2.145
23 5/8" 1.614 2.669 2.934 3.199 3.46431 1/2" 2.270 3.754 4.127 4.499 4.871
35 7/16" 2.598 4.297 4.723 5.149 5.57539 3/8" 2.926 4.839 5.319 5.799 6.27947 1/4" 3.582 5.924 6.512 7.100 7.68755 1/8" 4.238 7.009 7.705 8.400 N/A
59 1/16" 4.566 7.552 8.301 – –63" 4.894 8.094 8.897 – –
70 7/8" 5.550 9.179 – – –82 11/16" 6.534 – – – –
31 1/2"
Unit Height Max Opening
PCA EGRESS OPENINGS (m2)TRIPLE SASH, DSE16 HINGE
Unit Width 650 700 750
0.504 0.554 0.604 0.654
600 0.492 0.248 0.273 0.297 0.322800 0.692 0.349 0.383 0.418 0.453900 0.792 0.399 0.439 0.478 0.518
1000 0.892 0.450 0.494 0.539 0.5831200 1.092 0.550 0.605 0.660 0.7141400 1.292 0.651 0.716 0.780 –1500 1.392 0.702 0.771 – –1600 1.492 0.752 0.827 – –1800 1.692 0.853 – – –2100 1.992 – – – –
800
PUSH OUT CASEMENT WINDOW – EGRESS OPENING SCHEDULE
Unit Height Max Opening
PCA EGRESS OPENINGS (ft2)TRIPLE SASH, DSE12 HINGE
Unit Width 15 3/4" 19 11/16" 23 5/8"
PCA EGRESS – TRIPLE SASH, HP2 OR HP3 GLAZING & DSE12 HINGE
0.833 1.161 1.489 1.650
23 5/8" 1.614 1.345 1.875 2.404 2.66431 1/2" 2.270 1.892 2.637 3.382 3.747
35 7/16" 2.598 2.165 3.018 3.870 4.28839 3/8" 2.926 2.439 3.399 4.359 4.83047 1/4" 3.582 2.986 4.161 5.336 5.91255 1/8" 4.238 3.532 4.923 6.314 6.995
59 1/16" 4.566 3.806 5.304 6.803 7.53763" 4.894 4.079 5.685 7.291 8.078
70 7/8" 5.550 4.626 6.447 8.269 9.16182 11/16" 6.534 5.446 7.590 – –
25 9/16"
Unit Height Max Opening
PCA EGRESS OPENINGS (m2)TRIPLE SASH, DSE12 HINGE
Unit Width 400 500 600
0.254 0.354 0.454 0.503
600 0.492 0.125 0.174 0.223 0.247800 0.692 0.176 0.245 0.314 0.348900 0.792 0.201 0.280 0.360 0.398
1000 0.892 0.227 0.316 0.405 0.4491200 1.092 0.277 0.387 0.496 0.5491400 1.292 0.328 0.457 0.587 0.6501500 1.392 0.354 0.493 0.632 0.7001600 1.492 0.379 0.528 0.677 0.7501800 1.692 0.430 0.599 0.768 0.8512100 1.992 0.506 0.705 – –
649
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A67
Imperial Metric
Imperial Metric
Imperial Metric
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A68
SECTION 08550
WOOD [NON CLAD]: CASEMENT WINDOW UNITS
PART 1 GENERAL
1.01 SUMMARY
A Work Included: Furnish and install factory-assembled wood exterior Casement window units, includingglass and glazing, hardware and accessories; as indicated on Drawings and as specified herein.
B. Related Sections: Other Specification sections that directly relate to the work of this Section include, butare not limited to, the following:
1. Section 06100, Rough Carpentry: Wood framing.
2. Section 07210, Building Insulation: Batt and blanket insulation.
3. Section 07900, Joint Sealers: Perimeter sealants.
4. Section 09900, Painting: Painting and finishing.
1.02 PERFORMANCE REQUIREMENTS
A. General: Perform testing in accordance with AAMA/WDMA 101 I.S.2 and/or NAFS 1 and/or CSA A440.
B. Forced Entry: When tested in accordance with ASTM F588, shall be Grade 20/F-2 where applicable.
1.03 SUBMITTALS
A. Product Data: Submit manufacturer’s printed product data, test reports and installation instructions.
B. Shop Drawings: Submit shop drawings for approval. Include detailed plans, elevations, details, requiredrough openings, anchors and accessories. Include relationship with adjacent materials. Provideinstallation templates for work installed by others.
C. Samples: Submit representative samples of each material that is to be exposed in the completed work.Show full color ranges and finish variations expected.
1.04 QUALITY ASSURANCE:
A. Manufacturer: For each material type required for the work of this section, provide primary materials thatare the product of one manufacturer. Provide secondary or accessory materials that are acceptable to themanufacturer of the primary materials.
B. Installer: A firm with a minimum of three years experience in the type of work required by this Section.
C. Mock-Up: Prior to commencing the primary work of this section, provide a mock-up of each unit type at locations acceptable to Architect. Obtain Architect’s acceptance of visual qualities. Remove andreplace units that are not approved. Approved mock-ups built in place may be incorporated into thefinished work.
1.05 DELIVERY, STORAGE AND HANDLING
A. Deliver materials and products in factory labeled packages. Store and handle in strict compliance withmanufacturer’s instructions and recommendations. Protect from damage from weather, excessivetemperatures and construction operations.
WOOD [NON CLAD]: CASEMENT WINDOW UNITS
08550-1
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A69
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
1.06 WARRANTY
A. Provide manufacturer’s standard limited warranty covering the following:
1. Structural members and operating hardware are warranted against defects in material and
workmanship for a period of 10 years.
2. Insulating glass is warranted against material obstruction of transparency resulting from film
formation or dust collection on the interior surfaces for a period of 10 years and 20 years on
qualifying Heat-Smart® Systems.
PART 2 PRODUCTS
2.01 ACCEPTABLE MANUFACTURER
A. Provide units manufactured by Loewen (Loewen Inc. in the USA and C.P. Loewen Enterprises Ltd. in
Canada and internationally; 77 Highway 52 West, Steinbach, Manitoba R5G 1B2;
204-326-6446; 800-563-9367; www.loewen.com).
2.02 WOOD [NON-CLAD]: CASEMENT WINDOW UNITS
A. Wood Casement window units: Preglazed with insulating glass tested to AAMA/WDMA 101 I.S.2
and/or NAFS 1 and/or CSA A440 and/or CSA/AAMA/WDMA 101 I.S.2 A440. Tested for Air Leakage,
Water Leakage, Wind Resistance/Load.
1. Glass and Glazing Type:
a. Double-glazed [and Heat-Smart® Plus System 1].
b. Triple-glazed [and Heat-Smart® Plus System [2] [3]].
c. Special Glass Designs: ________.
2. Hardware: Roto gear operator with concealed heavy-duty hinges; sash locks; handle.
a. Nesting cover with folding handle.
b. Concealed multi-point concealed locking mechanism.
c. Finish: painted [Bronze][Linen][Sandstone][Black], plated [Antique Brass][Bright Brass].
[Brushed Chrome][Satin Nickel][Oil Rubbed Bronze] and solid bronze [Rustic Bronze] finishes.
3. Grilles:
a. Style: [Colonial][Heritage][Craftsman][________].
b. Simulated Divided Lites: [3/4"][1 1/8"][2"] Grille bars permanently applied to the interior and
exterior, with or without airspace grilles.
4. Insect Screen: Full-size; [Bronze][Linen][Sandstone][Black] frame color.
5. Double Weatherstrip: Flexible bubble and flexible bubble with semi-rigid fin seal.
2.03 MATERIALS AND COMPONENTS
A. Frame and Sash: Coastal Douglas Fir [Mahogany (Swietenia macrophylla)] kiln-dried lumber, preservative-
treated in accordance with NAFS 1/WDMA 101 I.S.-2/CSA-A440. Interior exposed surfaces are clear Fir
[Mahogany]; exterior surfaces factory primed [clear]. Jamb width [4 9/16" (116 mm)][6 9/16" (166 mm)]
[other].
B. Glass and Glazing: Factory sealed units of 3 mm clear glass with 1/2". (12 mm) airspace; wood stop at
interior face and foam tape gasket at exterior face.
C. Hardware: Steel components with Truth E-Gard coating.
WOOD [NON CLAD]: CASEMENT WINDOW UNITS
08550-2
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
D. Grilles: Manufacturer’s standard, unfinished clear wood grilles, interior mounted.
E. Insect Screen: Black anti-glare fiberglass cloth, set in aluminum frame fitted to inside of window,supplied complete with necessary hardware. Screen frame finish shall be baked enamel.
F. Finishes:
1. Exterior Wood Finish: Factory primed. Refer to Section 09900, Painting.
2. Interior Wood Finish: Unfinished, ready for site finishing. Refer to Section 09900, Painting.
PART 3 EXECUTION
3.01 PREPARATION
A. Examine substrates and conditions in which units will be installed. Do not proceed with installation untilunsatisfactory conditions are corrected.
3.02 INSTALLATION
A. Strictly comply with manufacturer’s instructions and recommendations, except where more restrictiverequirements are specified in this section. Coordinate installation with adjacent work to ensure propersequence of construction, clearances and support.
B. Apply caulking underneath sill, install units plumb, level, complete with drip flashing and in properrelationship with adjacent work. Install without twisting, bowing or springing. Anchor units securelyin place.
3.03 ADJUSTING AND CLEANING
A. Adjust hardware and operating parts for proper operation.
B. Clean exposed surfaces using manufacturer recommended materials and methods. Remove labels andvisible markings. Remove and replace work that cannot be successfully cleaned.
C. Touch-up damaged coatings and finishes using non-abrasive materials and methods recommended bymanufacturer. Eliminate all visible evidence of repair.
WOOD [NON CLAD]: CASEMENT WINDOW UNITS
08550-3
END OF SECTION
Specifications subject to change without notice.
© 2006 C.P. LOEWEN ENTERPRISES INC. All Rights Reserved.
A copyright license to reproduce this specification is hereby grantedto non-manufacturing architects, specification writers and designers.
Subject to Change Without Notice Effective May 2006 Printed in Canada
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A70
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A71
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
SECTION 08555
ALUMINUM CLAD: CASEMENT WINDOW UNITS
PART 1 GENERAL
1.01 SUMMARY
A. Work Included: Furnish and install factory-assembled aluminum clad Casement window units, includingglass and glazing, hardware and accessories; as indicated on Drawings and as specified herein.
B. Related Sections: Other Specification sections that directly relate to the work of this Section include, butare not limited to, the following:
1. Section 06100, Rough Carpentry: Wood framing.
2. Section 07210, Building Insulation: Batt and blanket insulation.
3. Section 07900, Joint Sealers: Perimeter sealants.
4. Section 09900, Painting: Painting and finishing.
1.02 PERFORMANCE REQUIREMENTS
A. General: Perform testing in accordance with AAMA/WDMA 101 I.S.2 and/or NAFS 1 and/or CSA A440.
B. Forced Entry: When tested in accordance with ASTM F588, shall be Grade 20/F-2 where applicable.
1.03 SUBMITTALS
A. Product Data: Submit manufacturer’s printed product data, test reports and installation instructions.
B. Shop Drawings: Submit shop drawings for approval. Include detailed plans, elevations, details, requiredrough openings, anchors and accessories. Include relationship with adjacent materials. Provideinstallation templates for work installed by others.
C. Samples: Submit representative samples of each material that is to be exposed in the completed work.Show full color ranges and finish variations expected.
1.04 QUALITY ASSURANCE:
A. Manufacturer: For each material type required for the work of this section, provide primary materials thatare the product of one manufacturer. Provide secondary or accessory materials that are acceptable to themanufacturer of the primary materials.
B. Installer: A firm with a minimum of three years experience in the type of work required by this Section.
C. Mock-Up: Prior to commencing the primary work of this section, provide a mock-up of each unit type atlocations acceptable to Architect. Obtain Architect’s acceptance of visual qualities. Remove and replaceunits that are not approved. Approved mock-ups built in place may be incorporated into the finished work.
1.05 DELIVERY, STORAGE AND HANDLING
A. Deliver materials and products in factory labeled packages. Store and handle in strict compliance withmanufacturer’s instructions and recommendations. Protect from damage from weather, excessivetemperatures and construction operations.
ALUMINUM CLAD: CASEMENT WINDOW UNITS
08555-1
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
1.06 WARRANTY
A. Provide manufacturer’s standard limited warranty covering the following:
1. Structural members and operating hardware are warranted against defects in material andworkmanship for a period of 10 years.
2. Insulating glass is warranted against material obstruction of transparency resulting from filmformation or dust collection on the interior surfaces for a period of 10 years and 20 years onqualifying Heat-Smart® Systems.
PART 2 PRODUCTS
2.01 ACCEPTABLE MANUFACTURER
A. Provide units manufactured by Loewen (Loewen Inc. in the U.S.A. and C.P. Loewen Enterprises Ltd. inCanada and internationally; 77 Highway 52 West, Steinbach, Manitoba R5G 1B2; 204-326-6446; 800-563-9367; www.loewen.com).
2.02 ALUMINUM CLAD: CASEMENT WINDOW UNITS
A. Aluminum clad Casement window units: Preglazed with insulating glass tested to AAMA/WDMA 101I.S.2 and/or NAFS 1 and/or CSA A440 and/or CSA/AAMA/WDMA 101 I.S.2 A440. Tested for AirLeakage, Water Leakage, Wind Resistance/Load.
1. Glass and Glazing Type:a. Double-glazed [and Heat-Smart® Plus System 1].b. Triple-glazed [and Heat-Smart® Plus System [2] [3]].c. Special Glass Designs: ________.
2. Hardware: Roto gear operator with concealed heavy-duty hinges; sash locks; handle.a. Nesting cover with folding handle.b. Concealed multi-point concealed locking mechanism.c. Finish: painted [Bronze][Linen][Sandstone][Black], plated [Antique Brass][Bright Brass]
[Brushed Chrome][Satin Nickel][Oil Rubbed Bronze] and solid bronze [Rustic Bronze] finishes.
3. Grilles:a. Style: [Colonial][Heritage][Craftsman][________].b. Simulated Divided Lites: [3/4"][1 1/8"][2"] Grille bars permanently applied to the interior and
exterior, with or without airspace grilles.
4. Insect Screen: Full-size; [Bronze][Linen][Sandstone][Black] frame color.
5. Double Weatherstrip: Flexible bubble and flexible bubble with semi-rigid fin seal.
2.03 MATERIALS AND COMPONENTS
A. Frame and Sash: Coastal Douglas Fir [Swietenia macrophylla Mahogany] kiln-dried lumber, preservative-treated in accordance with NAFS 1/WDMA 101 I.S.-2/CSA-A440. Interior exposed surfaces are clear Fir [Mahogany]; exterior surfaces aluminum clad. Jamb width [4 9/16" (116 mm)][6 9/16" (166 mm)] [other].
B. Glass and Glazing: Factory sealed units of 3 mm clear glass with 1/2" (12 mm) airspace; wood stop at interior face and foam tape gasket at exterior face.
C. Hardware: Steel components with Truth E-Gard coating.
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A72
ALUMINUM CLAD: CASEMENT WINDOW UNITS
08555-2
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
D. Grilles: Manufacturer’s standard, unfinished clear wood grilles, interior mounted.
E. Insect Screen: Black anti-glare fiberglass cloth, set in aluminum frame fitted to inside of window, suppliedcomplete with necessary hardware. Screen frame finish shall be baked enamel.
F. Finishes:
1. Exterior Aluminum Finish: Manufacturer’s [Standard][Architectural] palette; colors as selected frommanufacturer’s clad color spectrum.
2. Interior Wood Finish: Unfinished, ready for site finishing. Refer to Section 09900, Painting.
PART 3 EXECUTION
3.01 PREPARATION
A. Examine substrates and conditions in which units will be installed. Do not proceed with installation untilunsatisfactory conditions are corrected.
3.02 INSTALLATION
A. Strictly comply with manufacturer’s instructions and recommendations, except where more restrictiverequirements are specified in this section. Coordinate installation with adjacent work to ensure propersequence of construction, clearances and support.
B. Apply caulking underneath sill, install units plumb, level, complete with drip flashing and in properrelationship with adjacent work. Install without twisting, bowing or springing. Anchor units securely in place.
3.03 ADJUSTING AND CLEANING
A. Adjust hardware and operating parts for proper operation.
B. Clean exposed surfaces using manufacturer recommended materials and methods. Remove labels andvisible markings. Remove and replace work that cannot be successfully cleaned.
C. Touch-up damaged coatings and finishes using non-abrasive materials and methods recommended bymanufacturer. Eliminate all visible evidence of repair.
ALUMINUM CLAD: CASEMENT WINDOW UNITS
08555-3
END OF SECTION
Specifications subject to change without notice.
© 2006 C.P. LOEWEN ENTERPRISES INC. All Rights Reserved.
A copyright license to reproduce this specification is hereby grantedto non-manufacturing architects, specification writers and designers.
Subject to Change Without Notice Effective May 2006 Printed in Canada
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A73
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A74
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
SECTION 08550
WOOD [NON CLAD]: PUSH OUT CASEMENT WINDOW UNITS
PART 1 GENERAL
1.01 SUMMARY
A. Work Included: Furnish and install factory-assembled wood Casement window units, including glass andglazing, hardware and accessories; as indicated on Drawings and as specified herein.
B. Related Sections: Other Specification sections that directly relate to the work of this Section include, butare not limited to, the following:
1. Section 06100, Rough Carpentry: Wood framing.
2. Section 07210, Building Insulation: Batt and blanket insulation.
3. Section 07900, Joint Sealers: Perimeter sealants.
4. Section 09900, Painting: Painting and finishing.
1.02 PERFORMANCE REQUIREMENTS
A. General: Perform testing in accordance with AAMA/WDMA 101 I.S.2 and/or NAFS 1 and/or CSA A440.
B. Forced Entry: When tested in accordance with ASTM F588, shall be Grade 20/F-2 where applicable.
1.03 SUBMITTALS
A. Product Data: Submit manufacturer’s printed product data, test reports and installation instructions.
B. Shop Drawings: Submit shop drawings for approval. Include detailed plans, elevations, details, requiredrough openings, anchors and accessories. Include relationship with adjacent materials. Provideinstallation templates for work installed by others.
C. Samples: Submit representative samples of each material that is to be exposed in the completed work.Show full color ranges and finish variations expected.
1.04 QUALITY ASSURANCE:
A. Manufacturer: For each material type required for the work of this section, provide primary materials thatare the product of one manufacturer. Provide secondary or accessory materials that are acceptable to themanufacturer of the primary materials.
B. Installer: A firm with a minimum of three years experience in the type of work required by this Section.
C. Mock-Up: Prior to commencing the primary work of this section, provide a mock-up of each unit type atlocations acceptable to Architect. Obtain Architect’s acceptance of visual qualities. Remove and replaceunits that are not approved. Approved mock-ups built in place may be incorporated into the finished work.
1.05 DELIVERY, STORAGE AND HANDLING
A. Deliver materials and products in factory labeled packages. Store and handle in strict compliance withmanufacturer’s instructions and recommendations. Protect from damage from weather, excessivetemperatures and construction operations.
WOOD [NON CLAD]: PUSH OUT CASEMENT WINDOW UNITS
08550-1
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
1.06 WARRANTY
A. Provide manufacturer’s standard limited warranty covering the following:
1. Structural members and operating hardware are warranted against defects in material andworkmanship for a period of 10 years.
2. Insulating glass is warranted against material obstruction of transparency resulting from filmformation or dust collection on the interior surfaces for a period of 10 years and 20 years onqualifying Heat-Smart® Systems.
PART 2 PRODUCTS
2.01 ACCEPTABLE MANUFACTURER
A. Provide units manufactured by Loewen (Loewen Inc. in the U.S.A. and C.P. Loewen Enterprises Ltd. inCanada and internationally; 77 Highway 52 West, Steinbach, Manitoba R5G 1B2; 204-326-6446; 800-563-9367; www.loewen.com).
2.02 WOOD [NON-CLAD]: PUSH OUT CASEMENT WINDOW UNITS
A. Wood Casement window units: Preglazed with insulating glass tested to AAMA/WDMA 101 I.S.2 and/or NAFS 1 and/or CSA A440 and/or CSA/AAMA/WDMA 101 I.S.2 A440. Tested for Air Leakage, Water Leakage, Wind Resistance/Load.
1. Glass and Glazing Type:a. Double-glazed [and Heat-Smart® Plus System 1].b. Triple-glazed [and Heat-Smart® Plus System [2] [3]].c. Special Glass Designs: ________.
2. Hardware:a. Concealed 4-bar friction sash hinges.b. Single point sash locking handle [1 or 2 handles] or Multi-point locking handle optional.c. Finish: painted [Bronze][Linen][Sandstone][Black], plated [Antique Brass][Bright Brass]
[Brushed Chrome][Oil Rubbed Bronze][Brushed Nickel] and solid bronze [Rustic Bronze] finishes.d. Stainless steel concealed snubbers.e. Metal sash handle keepers on frame [1 keeper][2 keepers], painted brown.
3. Grilles:a. Style: [Colonial][Heritage][Craftsman][________].b. Simulated Divided Lites: [3/4"][1 1/8"][2"] Grille bars permanently applied to the interior and
exterior, with or without airspace grilles.
4. Swinging wood screen:a. Full size, opens in, hinged left or right.b. Removable pin butt hinges, 2 or 3 per screen.c. Hinge finish: Painted [Bronze][Linen][Sandstone][Black]; Plated [Oil Rubbed Bronze][Antique
Brass][Bright Brass][Brushed Chrome][Satin Nickel] and [Rustic Bronze].d. Black fiberglass screen cloth.e. Magnets [2 per screen] keep screen closed.f. Screen alignment pin.
5. Weatherstrip:a. Flexible bubble on frame [primary seal].b. Flexible bubble with semi-rigid fin seal on sash [secondary seal].
WOOD [NON CLAD]: PUSH OUT CASEMENT WINDOW UNITS
08550-2
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A75
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
2.03 MATERIALS AND COMPONENTS
A. Frame and Sash: Coastal Douglas Fir [Mahogany (Swietenia macrophylla)] kiln-dried lumber, preservative-treated in accordance with NAFS 1/WDMA 101 I.S.-2/CSA-A440. Interior exposed surfaces are clear Fir [Mahogany]; exterior surfaces factory primed [clear]. Jamb width [4 9/16" (116 mm)][6 9/16" (166 mm)][other].
B. Glass and Glazing: Factory sealed units of 3 mm clear glass with 1/2" (12 mm) airspace; wood stop at interior face and foam tape gasket at exterior face.
C. Hardware: Stainless steel components.
D. Grilles: Manufacturer’s standard, unfinished clear wood grilles, interior mounted.
E. Insect Screen: Black anti-glare fiberglass cloth, set in wood frame fitted to inside of window, supplied complete with necessary hardware.
F. Finishes:
1. Exterior Wood Finish: Factory primed. Refer to Section 09900, Painting.
2. Interior Wood Finish: Unfinished, ready for site finishing. Refer to Section 09900, Painting.
PART 3 EXECUTION
3.01 PREPARATION
A. Examine substrates and conditions in which units will be installed. Do not proceed with installation untilunsatisfactory conditions are corrected.
3.02 INSTALLATION
A. Strictly comply with manufacturer’s instructions and recommendations, except where more restrictive requirements are specified in this section. Coordinate installation with adjacent work to ensure propersequence of construction, clearances and support.
B. Apply caulking underneath sill, install units plumb, level, complete with drip flashing and in properrelationship with adjacent work. Install without twisting, bowing or springing. Anchor units securely in place.
3.03 ADJUSTING AND CLEANING
A. Adjust hardware and operating parts for proper operation.
B. Clean exposed surfaces using manufacturer recommended materials and methods. Remove labels andvisible markings. Remove and replace work that cannot be successfully cleaned.
C. Touch-up damaged coatings and finishes using non-abrasive materials and methods recommended bymanufacturer. Eliminate all visible evidence of repair.
WOOD [NON CLAD]: PUSH OUT CASEMENT WINDOW UNITS
08550-3
END OF SECTION
Specifications subject to change without notice.
© 2006 C.P. LOEWEN ENTERPRISES INC. All Rights Reserved.
A copyright license to reproduce this specification is hereby grantedto non-manufacturing architects, specification writers and designers.
Subject to Change Without Notice Effective May 2006 Printed in Canada
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A76
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
SECTION 08555
ALUMINUM CLAD: PUSH OUT CASEMENT WINDOW UNITS
PART 1 GENERAL
1.01 SUMMARY
A. Work Included: Furnish and install factory-assembled aluminum clad Casement window units, includingglass and glazing, hardware and accessories; as indicated on Drawings and as specified herein.
B. Related Sections: Other Specification sections that directly relate to the work of this Section include, butare not limited to, the following:
1. Section 06100, Rough Carpentry: Wood framing.
2. Section 07210, Building Insulation: Batt and blanket insulation.
3. Section 07900, Joint Sealers: Perimeter sealants.
4. Section 09900, Painting: Painting and finishing.
1.02 PERFORMANCE REQUIREMENTS
A. General: Perform testing in accordance with AAMA/WDMA 101 I.S.2 and/or NAFS 1 and/or CSA A440.
B. Forced Entry: When tested in accordance with ASTM F588, shall be Grade 20/F-2 where applicable.
1.03 SUBMITTALS
A. Product Data: Submit manufacturer’s printed product data, test reports and installation instructions.
B. Shop Drawings: Submit shop drawings for approval. Include detailed plans, elevations, details, requiredrough openings, anchors and accessories. Include relationship with adjacent materials. Provideinstallation templates for work installed by others.
C. Samples: Submit representative samples of each material that is to be exposed in the completed work.Show full color ranges and finish variations expected.
1.04 QUALITY ASSURANCE:
A. Manufacturer: For each material type required for the work of this section, provide primary materials thatare the product of one manufacturer. Provide secondary or accessory materials that are acceptable to themanufacturer of the primary materials.
B. Installer: A firm with a minimum of three years experience in the type of work required by this Section.
C. Mock-Up: Prior to commencing the primary work of this section, provide a mock-up of each unit type atlocations acceptable to Architect. Obtain Architect’s acceptance of visual qualities. Remove and replaceunits that are not approved. Approved mock-ups built in place may be incorporated into the finished work.
1.05 DELIVERY, STORAGE AND HANDLING
A. Deliver materials and products in factory labeled packages. Store and handle in strict compliance withmanufacturer’s instructions and recommendations. Protect from damage from weather, excessivetemperatures and construction operations.
ALUMINUM CLAD: PUSH OUT CASEMENT WINDOW UNITS
08555-1
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A77
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
1.06 WARRANTY
A. Provide manufacturer‘s standard limited warranty covering the following:
1. Structural members and operating hardware are warranted against defects in material andworkmanship for a period of ten years.
2. Insulating glass is warranted against material obstruction of transparency resulting from filmformation or dust collection on the interior surfaces for a period of 10 years and 20 years onqualifying Heat-Smart® Systems.
PART 2 PRODUCTS
2.01 ACCEPTABLE MANUFACTURER
A. Provide units manufactured by Loewen (Loewen Inc. in the USA and C.P. Loewen Enterprises Ltd. in anada and internationally; 77 Highway 52 West, Box 2260, Steinbach, Manitoba R5G 1B2; 204-326-6446; 800-563-9367; www.loewen.com.
2.02 ALUMINUM CLAD: PUSH OUT CASEMENT WINDOW UNITS
A. Aluminum clad Casement window units: Preglazed with insulating glass tested to AAMA/WDMA 101I.S.2 and/or NAFS 1 and/or CSA A440 and/or CSA/AAMA/WDMA 101 I.S.2 A440. Tested for AirLeakage, Water Leakage, Wind Resistance/Load.
1. Glass and Glazing Type:a. Double-glazed [and Heat Smart® PLUS System 1].b. Triple-glazed [and Heat Smart® PLUS System [2] [3]].
2. Hardware:a. Concealed 4-bar friction sash hinges.b. Single point sash locking handle [1 or 2 handles] or Multi-point locking handle optional.c. Finish: painted [Bronze] [Linen][Sandstone] [Black], plated [Antique Brass][Bright Brass][Brushed
Chrome][Polished Chrome][Oil Rubbed Bronze] [Satin Nickel], and solid [Rustic Bronze] finishes. d. Stainless steel concealed snubbers.e. Metal sash handle keepers on frame [1 keeper][2 keepers], painted brown.
3. Grilles:a. Style: [Colonial][Heritage][Craftsman][________].b. Between Glass Grilles: [White Metal][Square Brass][Pewter].
c. Simulated Divided Lites: [3/4"][1 1/8"][2"] Grille bars permanently applied to the interior and
exterior, with or without airspace grilles.
4. Swinging wood screen:a. Full size, opens in, hinged left or right.b. Removable pin butt hinges, 2 or 3 per screen.c. Hinge finish: Painted [Bronze][Linen][Sandstone][Black]; Plated [Oil Rubbed Bronze][Antique
Brass][Bright Brass][Brushed Chrome][Satin Nickel] and [Rustic Bronze].d. Black fiberglass screen cloth.e. Magnets [2 per screen] keep screen closed.f. Screen alignment pin.
5. Weatherstrip:a. Flexible bubble on frame [primary seal].b. Flexible bubble with semi-rigid fin seal on sash [secondary seal].
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A78
ALUMINUM CLAD: PUSH OUT CASEMENT WINDOW UNITS
08555-2
GUIDE SPECIFICATIONS FOR WINDOWS BY LOEWEN
GUIDE SPECIFICATIONS
2.03 MATERIALS AND COMPONENTS
A. Frame and Sash: Coastal Douglas Fir [Mahogany (Swietenia macrophylla)] kiln-dried lumber, perservative-treated in accordance with NAFS 1/WDMA 101 I.S.-2/CSA-A440. Interior exposed surfaces are clear fir [Mahogany]; exterior surfaces aluminum clad. Jamb width [4 9/16" (116 mm)][6 9/16" (166 mm)] [other].
B. Glass and Glazing: Factory sealed units of 3 mm clear glass with 1/2" (12 mm) airspace; wood stop at interior face and foam tape gasket at exterior face.
C. Hardware: Stainless steel components.
D. Grilles: Manufacturer’s standard, unfinished clear wood grilles, interior mounted.
E. Insect Screen: Black anti-glare fiberglass cloth, set in wood frame fitted to inside of window, suppliedcomplete with necessary hardware.
F. Finishes:
1. Exterior Aluminum Finish: Manufacturer’s [Standard] [Architectural] palette; colors as selected frommanufacturer’s clad color spectrum.
2. Interior Wood Finish: Unfinished, ready for site finishing. Refer to Section 09900, Painting.
PART 3 EXECUTION
3.01 PREPARATION
A. Examine substrates and conditions in which units will be installed. Do not proceed with installation untilunsatisfactory conditions are corrected.
3.02 INSTALLATION
A. Strictly comply with manufacturer’s instructions and recommendations, except where more restrictiverequirements are specified in this section. Coordinate installation with adjacent work to ensure propersequence of construction, clearances and support.
B. Apply caulking underneath sill, install units plumb, level, complete with drip flashing and in properrelationship with adjacent work. Install without twisting, bowing or springing. Anchor units securely in place.
3.03 ADJUSTING AND CLEANING
A. Adjust hardware and operating parts for proper operation.
B. Clean exposed surfaces using manufacturer recommended materials and methods. Remove labels andvisible markings. Remove and replace work that cannot be successfully cleaned.
C. Touch-up damaged coatings and finishes using non-abrasive materials and methods recommended bymanufacturer. Eliminate all visible evidence of repair.
ALUMINUM CLAD: PUSH OUT CASEMENT WINDOW UNITS
08555-3
END OF SECTION
Specifications subject to change without notice.
© 2006 C.P. LOEWEN ENTERPRISES INC. All Rights Reserved.
A copyright license to reproduce this specification is hereby grantedto non-manufacturing architects, specification writers and designers.
Subject to Change Without Notice Effective May 2006 Printed in Canada
Cas
em
en
t W
ind
ow
sw
ww
.lo
ew
en
.co
m
A79
Cas
em
en
t W
ind
ow
sC
anad
a an
d U
.S.A
. 1
.80
0.5
63
.93
67
/ I
nte
rnat
ion
al 2
04
.32
6.6
44
6
A80
Linen metal cladfixed Casements,
top and center.Simulated DividedLites in the centercourse. Operable