![Page 1: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/1.jpg)
CASE STUDY ON NON-DESTRUCTIVE TESTING
ON CONCRETE STRUCTURES
Submitted By :
Ankita Kulkarni (243037)
Sandhya Silotia (243072)
Sangamesh Kotarki (243074)
Non-Destructive Testing on Concrete Structures - A Case Study 1
Guided by : Prof. R. Satish Kumar
![Page 2: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/2.jpg)
Index:
Objective Scope Why NDT? Applications of NDT Various Methods of NDT Case Studies Conclusions Remedial Measures Limitations Bibliography
Non-Destructive Testing on Concrete Structures - A Case Study
2
![Page 3: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/3.jpg)
Objective
To Study the use, methodology & applicability of non destructive testing methods to check integrity of concrete structures through a case study.
Non-Destructive Testing on Concrete Structures - A Case Study
3
![Page 4: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/4.jpg)
Scope:
Suggest the methodology to be followed & applicability of non destructive testing.
Automatic interpretation of data from NDT, with the goal of detecting flaws accurately and efficiently.
To propose retrofitting techniques for structures failing in this kind of testing.
Non-Destructive Testing on Concrete Structures - A Case Study
4
![Page 5: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/5.jpg)
Case Studies :
1. EIGHT LANE ACCESS CONTROLLED EXPRESSWAY AS OUTER RING ROAD TO HYDERABAD CITY, PHASE II KOLLUR (KM. 12+000 TO PATANCHERU (KM. 23+700)
2. DRDL Laboratory building, single storied at Chandrayangutta, Secunderabad
3. Ambuja cements ltd.,Rajasthan
Non-Destructive Testing on Concrete Structures - A Case Study
5
![Page 6: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/6.jpg)
Non destructive testing
Non destructive testing is a technique for checking structural integrity after concrete hardening without damaging it.
Non-Destructive Testing on Concrete Structures - A Case Study
6
![Page 7: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/7.jpg)
Various methods of NDT
UPSV Test (Ultra sonic pulse velocity test)
Schmidt rebound hammer test Carbonation depth measurement test Half-cell potentiometer test Cover meter test Penetration Resistance test Resistivity measurement
Non-Destructive Testing on Concrete Structures - A Case Study
7
![Page 8: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/8.jpg)
Why NDT?
Strength on concrete depends on material, proper mixing & also workmanship at the time of placing
Conventional methods of testing of concrete does provide solution to assess actual strength or internal structure after hardening of concrete
In some cases, it required to assess of concrete damaged due to fire or any other natural calamity due judge the condition of structure
Non-Destructive Testing on Concrete Structures - A Case Study
8
![Page 9: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/9.jpg)
Application of NDT
quality control of pre-cast units or construction in situ
confirming or negating doubt concerning the workmanship involved in batching, mixing, placing, compacting or curing of concrete
location and determination of the extent of cracks, voids, honeycombing and similar defects within a concrete structure
determining the position, quantity or condition of reinforcement
confirming or locating suspected deterioration of concrete resulting from such factors as
overloading, fatigue, external or internal chemical attack or change, fire, explosion, environmental effect
Non-Destructive Testing on Concrete Structures - A Case Study
9
![Page 10: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/10.jpg)
USPV Test
This test is used for determination of the uniformity of concrete in and between members.
Reference code: IS 13311Part I 199 Principle:the velocity of an ultrasonic pulse
through any material depends upon the density, modulus of elasticity and Poisson’s ratio of the material.
Higher is the velocity, better is the quality of concrete
Non-Destructive Testing on Concrete Structures - A Case Study
10
![Page 11: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/11.jpg)
UPSV Contd…Equipment:
(a) Electrical pulse generator
(b) Pair of transducers (c) Amplifier (d) Electronic timing
machine
UPSV Equipment
•Equipment should be capable of measuring transit time over path lengths ranging from about 100 mm to the maximum thickness to be inspected to an accuracy of ±1%
Cost of equipment: Rs.2.15 lakhs
Non-Destructive Testing on Concrete Structures - A Case Study
11
![Page 12: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/12.jpg)
UPSV Contd…. Methodology
Calibration: done by measuring transit time on standard calibration rod.
Transducers arrangement: 3 methods
a) Direct Transmission
c) Surface Transmission
b) Semi Direct Transmission
Non-Destructive Testing on Concrete Structures - A Case Study
12
![Page 13: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/13.jpg)
Contd… USPV
Sr. No.
Ultrasonic Pulse Velocity by Cross probing (Km/Sec)
Concrete quality grading
1 Above 4.5 Excellent
2 3.5 to 4.5 Good
3 3.5 to 4.5 Medium
4 3.5 to 4.5 Doubtful
Velocity criterion for concrete quality grading is given by IS 13311 (Part-I):1992
Non-Destructive Testing on Concrete Structures - A Case Study
13
![Page 14: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/14.jpg)
SCHMIDT REBOUND HAMMER TEST
The Schmidt rebound hammer is basically a surface hardness tester.
IS: 13311 (Part 2): 1992 & BS 1881: Part 202: 1986
Principle :the rebound of an elastic mass depends on the hardness of the surface against which mass strikes.
Non-Destructive Testing on Concrete Structures - A Case Study
14
![Page 15: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/15.jpg)
Contd… Rebound Hammer
Non-Destructive Testing on Concrete Structures - A Case Study
15
Equipment: It Consist of a spring control hammer that slides on a plunger within a tubular housing. When the plunger is pressed against the surface of the concrete, the mass rebound from the plunger. It reacts against the force of spring. The Distance travelled by the mass, is called rebound number.
![Page 16: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/16.jpg)
Contd… Rebound Hammer
Non-Destructive Testing on Concrete Structures - A Case Study
16
![Page 17: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/17.jpg)
CARBONATION DEPTH MEASUREMENT TEST
Carbonation of concrete occurs when the carbon dioxide, in the atmosphere in the presence of moisture, reacts with hydrated cement minerals to produce carbonates
Due alkaline nature of concrete, reinforcement is protected from corrosion. This is neutralized by carbonation, thus reinforcement becomes prone to in presence moisture and oxygen.
Non-Destructive Testing on Concrete Structures - A Case Study
17
![Page 18: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/18.jpg)
Contd… Carbonation Test
The extent of carbonation is determined by testing concrete surface with a 1% phenolphthalein solution
The 1% phenolthalein solution is made by dissolving 1gm of phenolthalein in 90 cc of ethanol & the making it to 100cc by adding distilled water.
Change in colour is observed after test: No change in colour layer: Carbonation
affected Purple: No cabonation has taken place
Non-Destructive Testing on Concrete Structures - A Case Study
18
![Page 19: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/19.jpg)
HALF-CELL ELECTRICAL POTENTIAL METHOD This test is used to assess the corrosion conditions
in a reinforced concrete structure. ASTM C876 - 91 The apparatus includes copper-copper sulphate
half-cell, connecting wires and a high impedance voltmeter
external cathode is provided in the form of copper rod and copper sulphate solution in the cell. Any point on reinforcement bar inside the concrete body functioning as anode when connected electrically to cathodic half-cell generates e.m.f. This is measured by connecting a milli voltmeter in the circuit
Non-Destructive Testing on Concrete Structures - A Case Study
19
![Page 20: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/20.jpg)
Contd… Half Cell Electrical Method
Half cell potential (mV) reading
Percentage chance of activecorrosion
< -350 90%
-200 to –35050%
> -200 10%
The possibility of active corrosion is found out according to guideline below
Non-Destructive Testing on Concrete Structures - A Case Study
20
![Page 21: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/21.jpg)
Cover meter test
This test is used to assess the location and diameter of reinforcement bars and concrete cover.
Principle: based measurement of change of an elctromagnetic field caused by steel embedded in the concrete.
Equipment: profometer comprise a search head, meter and interconnecting cable. The concrete surface is scanned, with the search head kept in contact with it while the meter indicates, by analogue or digital means, the proximity of reinforcement
Non-Destructive Testing on Concrete Structures - A Case Study
21
![Page 22: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/22.jpg)
Case Study 1:EXPRESSWAY, KOLLUR Structure: EIGHT LANE ACCESS
CONTROLLED EXPRESSWAY AS OUTER RING ROAD TO HYDERABAD CITY, PHASE II KOLLUR (KM. 12+000 TO PATANCHERU (KM. 23+700)
Test conducted:A. Rebound Hammer tests to assess the in situ
compressive strength of cover concrete.B. USPV tests to assess the integrity of
concrete
Non-Destructive Testing on Concrete Structures - A Case Study
22
![Page 23: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/23.jpg)
Case study 1:
Test results: USPV TEST RESULTS Rebound Hammer test results
Results & Inferences: Concrete quality is found from “good to
excellent” according to UPSV tests results Concrete strength is varies from M35- M45
in rebound hammer test
Non-Destructive Testing on Concrete Structures - A Case Study
23
![Page 24: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/24.jpg)
Case Study 2 : DRDL Hyderabad
Non-Destructive Testing on Concrete Structures - A Case Study
24
Structure: DRDL laboratory building, single storied Columns size( B1 & B4) : 1’6” x 1’6” Columns size( A1, A2, A3, A4, B2, B3, C1, C2,
C3 & C4 ) : 1’0” x 1’6” Beam size –2’4” x 1’0”
Test conducted:a) UPSVb) Rebound hammer test Test results:a) UPSV test:b) Rebound hammer
![Page 25: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/25.jpg)
Case study 2:
Analysis & Results: Concrete quality is found to be “good” at
maximum locations .At some places it is found “medium & doubtful”.
On analyzing above rebound hammer test, it is found that the strength produced by the structures are more than the strength of Concrete of M-25.
Non-Destructive Testing on Concrete Structures - A Case Study
25
![Page 26: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/26.jpg)
Case study 2:
Non-Destructive Testing on Concrete Structures - A Case Study
26
![Page 27: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/27.jpg)
Case Study 3: Ambuja cements ltd.,Rajasthan Structures:
A. Cement silo: Dia 16.7 M & Height 51.0 M Test conducted:
A. Rebound Hammer tests to assess the in situ compressive strength of cover concrete.
B. USPV tests to assess the integrity of concrete.
C. Carbonation test to assess the depth of carbonated concrete.
D. Half cell potentiometer test to assess the probability of active corrosion.
E. Cover Meter test to estimate the cover provided.Non-Destructive Testing on Concrete Structures - A Case
Study
27
![Page 28: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/28.jpg)
Case Study 3:
Tests results: UPSV & Rebound hammer: Half cell potentiometer : Cover meter: Carbonation depth:
Results analysis & Inferences: columns ground level wall and Upper level
wall “Medium to good quality concrete” 10% probability of active corrosion exists.
Non-Destructive Testing on Concrete Structures - A Case Study
28
![Page 29: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/29.jpg)
Case study 3:
Results & Inferences: average cover provided to reinforcement in
columns and wall is about 40 mm which adequate acc. To IS 456
The carbonation test results on cores s as well as drill powder from concrete suggest that average depth of carbonation for columns is upto 10 mm & Wall can be considered upto 20mm, which can be considered as normal considering the age of the structure.
Non-Destructive Testing on Concrete Structures - A Case Study
29
![Page 30: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/30.jpg)
Case study 3:
Non-Destructive Testing on Concrete Structures - A Case Study
30
Silo structureFine crack in silo top slab
![Page 31: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/31.jpg)
Conclusion :
Various NDT methods can be used depending upon the type & age of structure to check the integrity of structure.
USPV, rebound hammer & covermeter can be applied to newly constructed structures to check the quality of concrete adequacy of cover before applying live load to the structures.
Half cell potentiometer & carbonation test can be applied to old structure to acess to carbonation depth & amount of corrosion occurred.
Non-Destructive Testing on Concrete Structures - A Case Study
31
![Page 32: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/32.jpg)
Remedial measures:
Replacement of cover concrete by microconcrete
Polymer Modified Mortar Treatment Protective Coating Jacketing Water proofing to slab
Non-Destructive Testing on Concrete Structures - A Case Study
32
![Page 33: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/33.jpg)
Limitation:
Lack of access, especially inside silo structures is a serious limitation in assessing the integrity of silo walls
Slabs are covered with water proofing membrane, it becomes difficult to get accurate through NDT.
If spalling or cracks are observed ,concrete remains no longer homogeneous, and tests like UPSV & rebound hammer becomes inapplicable, equipments for NDT are not made in India.
Equipments are very costly and not easily available.
Non-Destructive Testing on Concrete Structures - A Case Study
33
![Page 34: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/34.jpg)
Biblography:
Guidebook on non-destructive testing of concrete structures - INTERNATIONAL ATOMIC ENERGY AGENCY, VIENNA, 2002.
IS 13311 : Part 1 : 1992 Non-destructive testing of concrete: Part 1 Ultrasonic pluse velocity
IS 13311 : Part 2 : 1992 Methods of non-destructive testing of concrete: Part 2 Rebound hammer
MS shetty:Concrete technologyNon-Destructive Testing on Concrete Structures - A Case
Study
34
![Page 35: Case study on non destructive testing on concrete structures](https://reader033.fdocuments.in/reader033/viewer/2022061613/555063f5b4c905ae3f8b5586/html5/thumbnails/35.jpg)
Thank you for Your Attention…
Non-Destructive Testing on Concrete Structures - A Case Study
35