Case Studies from Blood Assurance - SEABB

14
Case Studies from Blood Assurance Vonya Drinnon BSMT(ASCP)

Transcript of Case Studies from Blood Assurance - SEABB

Page 1: Case Studies from Blood Assurance - SEABB

Case Studies from Blood Assurance

Vonya Drinnon BSMT(ASCP)

Page 2: Case Studies from Blood Assurance - SEABB

Some of our crew: Jesse, Melissa, Kathy, Carol, Chris, Amy

Laura, Joyce

Page 3: Case Studies from Blood Assurance - SEABB

Office Staff: Wendy (secretary); Sue (lab manager); Mona (lab director); me (lab manager)

Page 4: Case Studies from Blood Assurance - SEABB

DONOR. Tango pool screen W+

Page 5: Case Studies from Blood Assurance - SEABB

Female patient No diagnosis listed Needs blood

Page 6: Case Studies from Blood Assurance - SEABB

1 of 2 panels tested. (other panel showed similar results)

Page 7: Case Studies from Blood Assurance - SEABB

Chose select cells with Ficin to verify the anti-C

Page 8: Case Studies from Blood Assurance - SEABB

FICIN my friend! The panel gives away the secretes by:

1. shading the antigens destroyed 2. leaving the enhanced Ags non shaded.

But sometimes the friend can deceive you because Cold antibodies are also enhanced. That’s why when we confirm Antibodies with Ficin we also test cells that we expect to be negative

Page 9: Case Studies from Blood Assurance - SEABB

A good tool for the generalist stuck in Blood Banking:

(or anyone that likes fun apps)

Ortho Blood Banker App. Smart phone free app.

Key in Rh phenotype and the app will supply the frequency of matching donors.

Example, D,C,E POS; c,e neg % Frequency of matching donors: <1.01

black, <0.01 Asian, <0.01 white

Example, c,e POS; D,C,E neg % Frequency of matching donors: 6.8

black, 0.1 Asian, 15.1 white

Page 10: Case Studies from Blood Assurance - SEABB

Male. 46y. O Pos.

my all time favorite “Diagnosis”: Anemia Notice the difference in the gel screen VS tube screen

Page 11: Case Studies from Blood Assurance - SEABB

Saline replacement: plasma or serum + cells. Incubate 30”-1hr. Spin.

Remove supernate. Add 2 drops saline. Re-suspend Spin Read Add coombs. Etc.

Anti-K & Strong Rouleaux

Page 12: Case Studies from Blood Assurance - SEABB

Female. 77y. A neg. Diagnosis: (none) Past Transfusions: unknown

Page 13: Case Studies from Blood Assurance - SEABB

Tech has used this panel to mark her rule outs.

See other panels to view how she eliminated antigens

Page 14: Case Studies from Blood Assurance - SEABB

Cell #6 is marked NT. It was Not Tested. Likely due to contamination or spillage. (life happens)

I accidently cut it off but, tech later tested #5 & #9 with ficin to double check on the C both cells were negative with ficin