Cardiac Surgery & Percutaneous Cardiac Interventions Data ...
CARDIAC meeting – 30 Sept 05 [email protected] M3R3-M5R3-M5R4 FEE status.
-
Upload
cathleen-wood -
Category
Documents
-
view
213 -
download
0
Transcript of CARDIAC meeting – 30 Sept 05 [email protected] M3R3-M5R3-M5R4 FEE status.
CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
M3R3-M5R3-M5R4
FEE status
22CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
OverviewOverview
FEE – from ASDQ to CARDIAC• ASDQ++• CARDIAC
• I2C induced signals
HV induced noise• HV noise coupling
LV distribution• Regulator Vout spread & LV distribution bars Vdrop
CARDIAC threshold scan• M3R3 – M5R3 – M5R4
Grounding• Detector grounding scheme
Conclusions
33CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
ASDQ++ASDQ++A brief history (I)A brief history (I)
• Nightmare first two chambers prototypes test fee instability cable layout/orientation sensitivity
• ASDQ++ PCB rel. 2 small improvement on the instability side still problems with cabling
• Buffer board & FC connections fully stable fee behavior no dependency on cable layout
- Some capacitors for supply voltage decoupling- inner layers for GND/V+/V-
44CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
ASDQ++ASDQ++A brief history (II)A brief history (II)
Programmable current sink
ASDQ output stage
standard current set : 3 mA (300 mV/100 ) current set for driver board : 1 mA (300 mV/300 )
R=300
SPBASDQ++Ground connectionFaraday cage
HV
1 M
680 nF
Faraday Faraday CageCage
sensitive path
Cathode pads readout
LVDS
55CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
ASDQ++ASDQ++A brief history (III)A brief history (III)
• Pads X-talk charge injection in pads belonging to the same pad wire charge injection in contiguous pad wires
HV
Signal on this wire pad
Signal injection
Signal injection
charge injection in pads belonging to the same pad wire poor ground connection (capacitor-GND)
charge injection in contiguous pad wires nose ground not enough a resistor in the grounding path mitigates the problem and help with HV & pickup noise
ZGND < ZWire Pads
HV nose
66CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
The IB System architectureThe IB System architectureThe IB and the TB boardsThe IB and the TB boards
HV
Signal on this wire pad
Signal injection
Signal injection
ZGND << ZWire Pads
HV nose
22
In the last T11 TB 4 CARIOCA (NOT CARDIAC !!!) boards were installed in one of our M3R3 chamber. We took some data @ Vth 6/7 fC
77CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
CARDIACCARDIACI2C induced signals (I)I2C induced signals (I)
I2C
AB
CD
EF
Termination
88CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
CARDIACCARDIACI2C induced signals (II)I2C induced signals (II)
Read ScalerRead all registers
M3R3 CARDIAC : A – B – C – D [all channels]
M3R3 CARDIAC : F [1° (?) channel – other channels ok]
Read all registers Read Scaler
NB : 5 pulses are generated by the readout procedure (?!) ask to Valerio
CASINO
?
I2C
CARDIACout
I2C
CARDIACout
I2C
CARDIACout
99CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
CARDIACCARDIACI2C induced signals (III)I2C induced signals (III)
I2C
AB
CD
EF
Termination
All boards/all channels OKProblems in the PCB due to high frequency signal components
CARDIAC F – 1° channel
1010CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
CARDIACCARDIACI2C induced signals (IV)I2C induced signals (IV)
Termination
I2C
AB
C
DE
F
No ch1 problem with M5R3 chamber ??!!M3R3 – M5R3 difference : Cpad value
M5R3
Cpad
I2C line
Z1 Z2
I1 I2
CARIOCACparasitic
What are we going to have with smaller Cpad
and shorter interconnection cables ?
1111CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
HV induced noiseHV induced noiseNoise couplingNoise coupling
Continuous cathode
Wire
Cathodes
HV distribution line = antenna
Inoise
filter HV before distribution line
6 cm
V < 5 VC = 2.2 nF
1212CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
LV distributionLV distributionRegulator output voltage spreadRegulator output voltage spread
Iload=1.5A
60 mm
LV distribution bars - PCB dimension for region R4
800 mm
R=0.45 m/□ R = (800/30)*0.45 m Voltage drop ~ 20mV (< 1% Vcc)
GNDVCC
1313CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
CARDIAC threshold scanCARDIAC threshold scanM3R3 – M5R3 – M5R4M3R3 – M5R3 – M5R4
M3R3• 100 Hz @ 4.4 fC (working threshold = 5 fC)
M5R3• 100 Hz @ 6.4 fC (working threshold = 5 fC)
M5R4• 100 Hz @ 8.2 fC (working threshold = 10 fC)
HV ON
1414CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
GroundingGroundingDetector grounding schemeDetector grounding scheme
No current through the reference GND Reference GND = Safety GND
3 A fuses on the LV distribution system1 mA max current on the HV lines
Low step up current in case of failure
No current through the reference GND Reference GND = Safety GND
3 A fuses on the LV distribution system1 mA max current on the HV lines
Low step up current in case of failure
system reference ground safety ground
1515CARDIAC meeting – 30 Sept 05CARDIAC meeting – 30 Sept 05 [email protected]@lnf.infn.it
System qualificationSystem qualificationSkew measurements Skew measurements M4(M5)R3 M4(M5)R3
To verify front-end behavior threshold scan should be executed WITHOUT HV ON (HV is a source of external noise and can be filtered out), anyway FEE work fine with the 3 instrumented chambers
No instability due to cable layout or external source has been detected
HV filters are OK with the HV PS we have used in our test, but that PS is not the final one !
LV boards and LV distribution are OK (~10 mV drop for M3R3 regions and ~20 mV for M4R4 regions)
The detector grounding scheme has already been (successfully) reviewed
The 3 instrumented chambers work fine (NB : M5R3 is not instrumented with the final FC)
I2C access can trigger CARDIAC output spurious pulses ONLY during CARDIAC access
According to our tests CARDIAC work fine when used to instrument M3R3, M5R3 and M5R4 chambers