Capillary Electrophoresis: Technique and Application
Transcript of Capillary Electrophoresis: Technique and Application
![Page 1: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/1.jpg)
CAPILLARY ELECTROPHORESIS: TECHNIQUE AND APPLICATIONBy Vanessa Hobbs
![Page 2: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/2.jpg)
CAPILLARY ELECTROPHORESIS
![Page 3: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/3.jpg)
DEVELOPMENT OF CAPILLARY ELECTROPHORESIS 1803 F.F. Reuss Clay Slab 1886 O. Lodge Zone Electrophoresis 1937 A. Tiselius Electrophoretic Cell 1967 S. Hjerten Rotating tubes (300 um) 1970 V. Neuhoff PAG filled tubes 1979 Mikkers, Everaerts, Verheggen FZE 1981 Jorgenson and Lukags 75 um cap. 1983 Micellar Electrokinetic Chrom. 1988 Commercial introduction
![Page 4: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/4.jpg)
ELECTROOSMOTIC FLOW
http://www.electrokinetic.co.uk/images/tech1.gif
![Page 5: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/5.jpg)
MOVEMENT OF ANALYTE Analyte
ν = µ E ν = velocity µ = electrophoretic mobility E = Electric field
Electrophoretic mobility µ = q/[6πηr] q = charge η = solution viscosity r = radius
Electroosmotic flow νEOF = [ε/4πη]ζE ε = dielectric Constant ζ = Zeta potential
Flow of migration ν = [(μEO + μe)V]/L V = potential L = length of capillary
Forensic Science International77 (1996) 211 - 229
![Page 6: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/6.jpg)
INJECTION OF SAMPLE
Current Analytical Chemistry. 2005, 1http://www.calstatela.edu/dept/chem/gomez/pubs-pdf/flow-injection.pdf
![Page 7: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/7.jpg)
INJECTION OF SAMPLE Injection is difficult due to sample size Electrokinetic Injection
Differs by analyte Hydrodynamic
Many parameters
Anal. Chem., 1997, 69 (15), pp 2952–2954
![Page 8: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/8.jpg)
INJECTION OF SAMPLES
Anal. Chem.2001, 73,1974-1978
![Page 9: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/9.jpg)
INJECTION OF SAMPLE
Current Analytical Chemistry. 2005, 1http://www.calstatela.edu/dept/chem/gomez/pubs-pdf/flow-injection.pdf
![Page 10: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/10.jpg)
CAPILLARY ZONE ELECTROPHORESIS Separated by mass to charge ratio Based on Electroosmotic Flow Detectors:
UV Detector – Beer’s Law Laser Fluorescence – Deriv. MS - electrospray Chemiluminescence Diode Array Detector Indirect Refractive Index
Compare with HPLC and GC Neutral Compounds Chiral Compounds
![Page 11: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/11.jpg)
INCREASING PATH LENGTH
http://www.chem.agilent.com/Library/technicaloverviews/Public/5989-9808EN.pdf
![Page 12: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/12.jpg)
MICELLAR ELECTROKINETIC CHROMATOGRAPHY
UVNeutral compoundsComprable to HPLC
![Page 13: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/13.jpg)
Capillary Electrochromatography Packed column with no pressure applied, only
electroosmotic pressure.
![Page 14: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/14.jpg)
CAPILLARY GEL ELECTROPHORESIS Crosslinked vs. non crosslinked DNA sequencing Protein analysis Chirality possible EOF less desirable
![Page 15: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/15.jpg)
CAPILLARY GEL ELECTROPHORESIS
http://www1.qiagen.com/Images/Catalog/2134.jpg
![Page 16: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/16.jpg)
CAPILLARY ISOELECTRIC FOCUSING
http://www.targetdiscovery.com/~tdidocs/App_Note_5_200405.pdf
![Page 17: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/17.jpg)
CAPILLARY ISOELECTRIC FOCUSING pH gradient Sample focusing and detection Movement of gradient towards the detector
Zone broadening Not useful for chiral compounds
![Page 18: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/18.jpg)
CAPILLARY ISOTACHOPHORESIS Two buffers form ionic zones Anions and Cations seperately Neutral compounds Used for concentration EOF less desirable
![Page 19: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/19.jpg)
APPLICATIONSCE and Analysis of Illicit Drugs
![Page 20: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/20.jpg)
HPLC Heroin Analysis
![Page 21: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/21.jpg)
HPLC Analysis of Heroin (SPE)Fig. 2. (a) Representative total ion chromatograms of all quantifiable analytes spiked at LLQ level in human plasma (5 ng/mL). The intensity of the deuterated analytes was above 2500 [cps]. (b) Representative total ion chromatograms of random chosen patient’ plasma sample. (c) Total ion chromatogram of a plasma sample of a non-drug using volunteer. (A) M3G and M3G-d3; (B) morphine and morphine-d3; (C) M6G; (D) 6-MAM; (E) heroin and heroin-d6; (F) = methadone and methadone-d9; (G) EMDP; (H) cocaine; (I) benzoylecgonine. DIODE ARRAY AND TRIPLE MS
5 ng/ml
![Page 22: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/22.jpg)
FIRST PUBLISHED ANALYSIS OF ILLICIT DRUGS
![Page 23: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/23.jpg)
FIRST PUBLISHED ANALYSIS OF ILLICIT DRUGS
Relative Standard DeviationMigration 0.5%Peak Area 4 – 8%
Twice as many peaks observed in Heroin analysis with MEKCHPLC more sensitiveSmaller capillary did not help analysis with MEKC
![Page 24: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/24.jpg)
LSD Analysis with Laser Fluorescence
![Page 25: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/25.jpg)
LSD Analysis with Laser Fluorescence (0.2 ng/ml)
![Page 26: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/26.jpg)
METHAMPHETAMINE ANALYSIS
50 μm Capillary with length of 40 cm
UV Detector
Electrophoresis 2006, 27, 4711–4716
![Page 27: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/27.jpg)
METHAMPHETAMINE ANALYSIS
50 mL of 0.1 mol/L NaOH was added to 100 mL of urinemixing by a vortex mixer for about 1 min. 1000 mL of ethyl acetate was pipetted incontinued mixing for 30 min. centrifuged for 5 min at 5000 rpm. the upper organic layer was carefully transferred to another polyethylene tube, 20 mL of 1.0 mol/L HCl was addedevaporated to dryness at 60oCresidues were then dissolved in 100 mL of doubly distilled water
Electrophoresis 2008, 29, 3999–4007
![Page 28: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/28.jpg)
METHAMPHETAMINE ANALYSIS
50 mL of 0.1 mol/L NaOH was added to 100 mL of urinemixing by a vortex mixer for about 1 min. 1000 mL of ethyl acetate was pipetted incontinued mixing for 30 min. centrifuged for 5 min at 5000 rpm. the upper organic layer was carefully transferred to another polyethylene tube, 20 mL of 1.0 mol/L HCl was addedevaporated to dryness at 60oCresidues were then dissolved in 100 mL of doubly distilled water
Electrophoresis 2008, 29, 3999–4007
![Page 29: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/29.jpg)
ANALYSIS (LIQUID LIQUID EXTRACTION)
Electrophoresis 2008, 29, 4078–4087
![Page 30: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/30.jpg)
ANALYSIS OF HAIR
Electrophoresis 1998, 19, 42-50
![Page 31: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/31.jpg)
ANALYSIS OF BLOOD
Biomed. Chromatogr. 19: 737–742 (2005)
![Page 32: Capillary Electrophoresis: Technique and Application](https://reader034.fdocuments.in/reader034/viewer/2022051007/5868bd5d1a28ab61568baa23/html5/thumbnails/32.jpg)
REFERENCES Garvin, D and Ajuhar, S. Handbook of Isoelectric Focusing and Proteomics. 7th Volume. 1995: pgs 14-15, 181 - 191.
Tiselius, A. Electrophoresis of Serum Globulin. Biochem. J. 1937, 31: 313 – 317. Van Oss, C. Interfacial Forces in Aqueous Media. 1994: pg 145. Hjerten, S. Free Zone Electrophoresis. Chromatogr. Rev. 1937, 9: 122 – 219. Neuhoff, V., Wolf-Bernhard, S., and Sternbach, H. Micro-analysis of Pure Deoxyribonucleic-dependant Ribonucleic
Polymerase from E. Coli. Biochem. J. 1970, 117: 623 – 631. Camilleri, P. Capillary Electrophoresis: Theory and Practice. 2nd Edition. CRC Press. 1997: pgs 5-6. Jorgenson, and Lukags. Zone Electrophoresis in Open Tubular Glass Capillaries. Anal. Chem. 1981, 53: 1298 – 1302 Otto, M., Valcarcel, M. and Widmer, H. M. Analytical Chemistry. 2nd edition. Wiley. 2004: pgs 616-618. Wallingberg, R. and Ewing, A. Capillary Zone Electrophoresis with Electrochemical Detection. Anal. Chem. 1987,
59(14): 1762 – 1766. Rejtar, T. et. al. Off line coupling of High Resolution Capillary Electrophoresis to MALDI-TOF and TOF/TOF MS. J
Proteome Res. 2002, 1(2): 171 - 179 Hashimoto, M. et. al. Microchip Capillary Electrophoresis using on-line chemiluminesce. J. Chrom. A. 2000, 867:271
– 279. Heiger, D. et. al. Diode Array Detection in Capillary Electrophoresis. Electrophoresis. 2005, 15:1234 – 1247. Paez, X. and Hernandez, L. Biomedical Applications of Capillary Electrophoresis with Laser Induced Fluorescence
Detection. Biopharm. Drug Dispos. 2001, 22:273 – 289. Terabe, S. et. al. Electrokinetic seperations with Micellar Solutions and Open Tubular Capillaries. Anal. Chem. 1984,
56: 111 – 113. http://www.chemistry.or.jp/gakujutu/bcsj/bc-cont/b98nov_gif/kea1009con.gif Altria, K. Capillary Electrophoresis Handbook: Principles, Operations, and Applications. Version 52. 1996: pgs 158 –
158. Chankvetadze, B. Capillary Electrophoresis in Chiral Analysis. 1997: pgs 43- 46.