CAP2D Connected Access Portal 2-Door Controller ... · Relay Indicator LED lights ... RED GRN 12V...
Transcript of CAP2D Connected Access Portal 2-Door Controller ... · Relay Indicator LED lights ... RED GRN 12V...
-
LiftMaster CloudTM
Connected Access Portal 2-Door Controller
INSTALLATION MANUAL
Mod
el C
AP
2D
-
2
PRE-INSTALL NETWORKWIRING ACCESS CONTROLINTRODUCTION INSTALL
INTRODUCTIONSafety ............................................................................ 3Controller Overview ....................................................... 4Control Board Overview ................................................ 4Carton Inventory ........................................................... 5Tools Needed ................................................................ 5Dimensions ................................................................... 5Specifi cations ................................................................ 6Electrical Ratings........................................................... 6Wire Specifi cations ....................................................... 7
PRE-INSTALLInternet Service ............................................................. 8CP# for Controller ......................................................... 8Setup a LiftMaster Cloud Account ................................. 8Mount the Bracket ......................................................... 9
WIRINGConnect Power ............................................................ 10
NETWORK
Connect Internet .......................................................... 11
ACCESS CONTROLAdmin Mode ................................................................ 12Wiring REX and Doors ................................................ 12Operation .................................................................... 14Gate Access................................................................. 15Door Access ................................................................ 16
Confi guration Sheet .................................................... 18Legal Disclaimers ...................................................... 19Warranty ..................................................................... 19
1
2
3
4
INSTALL5Install the CAP2D ........................................................ 17Troubleshooting .......................................................... 17
For LiftMaster Cloud programming please visit www.LiftMasterCloud.com.
-
3
To reduce the risk of SEVERE INJURY or DEATH: Disconnect power at the fuse box BEFORE proceeding. To AVOID damaging gas, power or other underground utility
lines, contact underground utility locating companies BEFORE digging.
ALL electrical connections MUST be made by a qualified individual.
ALL power and control wiring MUST be run in separate conduit.
To protect against fire and electrocution: Disconnect power BEFORE installing or servicing controller. NEVER connect a keypad/reader or lock to doors without first
consulting the applicable fire code. You MUST consult with, and get approval from, local fire
officials BEFORE installing locks or devices on ANY doors that may be fire exits.
Use of egress push buttons may not be legal. Single action exits may be required.
ALWAYS obtain proper permits and approvals in writing BEFORE installing equipment.
SafetySafety Symbol and Signal Word Review When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your property or product if you do not comply with the cautionary statements that accompany it. Read them carefully.
MECHANICAL
ELECTRICAL
PRE-INSTALL NETWORKWIRING ACCESS CONTROLINTRODUCTION INSTALL
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
UNDERWRITERS LABORATORIES (UL) COMPLIANCE
The CAP2D complies with the UL294 Standard for access control units with the following restrictions: The system relay contacts shall not be confi gured in the fail
secure mode unless permitted by the local authority having jurisdiction and shall not interfere with the operation of panic hardware.
The Ethernet port is for supplemental use only, the unit will continue to operate standalone if the network connection is interrupted.
This unit can be powered over Ethernet via PoE Compatible hardware. Where used, any PoE power source must be UL294 Listed.
All interconnecting devices must be UL Listed.
DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. Doing so may cause interference with the operation of panic hardware.
-
4
PRE-INSTALL NETWORKWIRING ACCESS CONTROLINTRODUCTION INSTALL
Controller Overview
Control Board Overview
NETWORK LED Orange LED: 100MBit LinkBlue LED: Network activityRight Blue LED: Good connection to the network
ACTIVE LEDOFF/Solid: System is starting
Blinking: System operational.STATUS LEDSolid: System has power
Control Board Connection Description
Administrative USB Connect via Mini-USB to access administrative
LAN/PoE Connect to network. May also carry 802.3af/at power
Backup Lithium Battery Battery preserves the systems data during primary power outages
Local Heartbeat LED indicates proper function
Relay Indicator LED lights when relay is engaged (one per relay)
Power Confi guration Jumper selects between PoE and Auxiliary Power
FRONT VIEW
LAN
AD
MIN
DRY
RLY1
WET
PSE1
PoE
DRY
WET
RLY2
HRT
BT
REA
DER
1IO
1
REX
COM
DO
OR
RED
GRN
12V
BU
Z
GN
D
D1
D
0
IO
2
REX
COM
DO
OR
REA
DER
2
RED
GRN
12V
BU
Z
GN
D
D1
D
0
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
-12I
N+
ADMINISTRATIVE USB
DOOR
1DO
OR 2
Auxiliary Relay 1
REQUEST TO EXITSTATUS
WIEGAND INPUT
REQUEST TO EXITSTATUS
WIEGAND INPUT
POWER CONFIG JUMPER
EXTERNAL 12V POWER
BACKUP LITHIUM COIN BATTERY (CR1220)
LAN/PoE Connector
LOCAL HEARTBEAT LED
Primary Relay 1
Auxiliary Relay 2
Primary Relay 2
-
5
PRE-INSTALL NETWORKWIRING ACCESS CONTROLINTRODUCTION INSTALL
Door Controller USB Cable Diodes Installation Manual
Carton Inventory
Tools Needed PH2 Phillips Screwdriver Precision 1/8" Flat or PH0 Phillips Screwdriver 1/4" Nut Driver Drill/Driver 7/64" Drill Bit Hammer Drill Bits for Drill/Driver RJ45 Crimping Pliers Multimeter Measuring tape Conduit Bender Conduit Cutter/Reamer Hack Saw Center Punch Tool Hammer
Dimensions
4-1/2" (11.4 cm)
3" (7.6 cm)1-1/4" (3.2 cm)
.36" (.9 cm)
-
6
PRE-INSTALL NETWORKWIRING ACCESS CONTROLINTRODUCTION INSTALL
Specifi cationsCAP2D Capacity People: 25,000 / Events: 8,000CAP2D Operating Temperature Range 32F to 125F (0C to 49C)CAP2D Operational Humidity 5% to 95% non-condensingStorage and Shipping Temperature Range -40F to 149F (-40C To 65C) Wiegand Inputs (2) 26Bit, 30Bit. The CAP2D is compatible with Wiegand devices that transmit up to
255 bit data2 Primary and 2 Auxiliary Relay Outputs SPDTAccessory Compatibility Refer to the accessory page for compatible accessoriesNetwork Compatibility 10/100/1,000 EthernetWire Specifi cation RJ-45 Wired Ethernet
Electrical Ratings
POWER IN VOLTAGE POWER (MIN)Auxiliary Input 12 VDC 13 Watts
Power Over Ethernet 44-57 VDC 13 Watts
POWER OUT VOLTAGE CURRENT (MAX)Relays (wet) 12 VDC 750mA (combined)
Wiegand Readers 12 VDC 750mA (combined)Relays (dry-inductive) 30 VDC (max) 2,000mA
NOTE: IP Door Controller is to be connected to UL Listed Commercial 294 or 603 Power Supply for Auxiliary, or UL Listed 294/294b PoE Listed power supply for Power over Ethernet.
-
7
Wire Specifi cationsUse this chart to pull wires in preparation of your installation.
DESCRIPTION OF WIRE RUN WIRE SPECIFICATION MAXIMUM RUN DISTANCEPower Wire, secondary DC output 2-Conductor 14 AWG
2-Conductor 16 AWG
2-Conductor 18 AWG
Up to 60 feet (18.3 m)
Up to 37 feet (11.3 m)
Up to 24 feet (7.3 m)
Local Area Network (LAN)CAT 5/6 Network Cable
8-Conductor, 24 AWG Twisted pair 328 feet* (100 m)
Door Strike/LiftMaster Gate Operator 2-Conductor 18-22 AWG Shielded 100 - 250 feet (30.5 - 76.2 m)
Magnetic Lock 2-Conductor 18-22 AWG 50 - 125 feet (15.2 - 38.1 m)
Dry Contact Closure (Most Gate Operators) 2-Conductor 18-22 AWG Shielded 500 - 2500 feet (152.4 - 762 m)
Exit Request (REX) 2-Conductor 18-22 AWG 500 feet (152.4 m)
Supervised Input 2-Conductor 18-22 AWG 500 feet (152.4 m)
Wiegand/Proximity Readers 7-Conductor 18-22 AWG Shielded 500 feet (152.4 m)
NOTE: Main power supply and control wiring MUST be run in separate conduits. Conduits must be UL approved for low and high voltage. Refer to the NEC, ANSI/NFPA 70 for additional wiring requirements.
NOTE: Place the CAP2D unit within 500 feet of its associated electronic strike or latch. Monitoring Software is not UL evaluated.
Always provide power from a dedicated source. Plug provided transformer into an outlet wired to its own 10 Amp minimum circuit breaker. This will prevent two problems:
Other equipment cannot introduce spikes, noise, surges or dips into the power circuit that will affect the system. The systems operation will not be affected if any other equipment develops a short circuit across the power line.
* CAT 5/6 NETWORK CABLE NOTES:
For outdoor distances exceeding 140 feet (42.7 m), a UL497 compliant primary surge protector MUST be installed at the controller.
Distances exceeding 328 feet (100 m) can be accommodated with additional hardware. Contact Technical Support for more information. Additional hardware was not evaluated under UL294.
PRE-INSTALL NETWORKWIRING ACCESS CONTROLINTRODUCTION INSTALL
-
8
1 Internet ServiceThe controller MUST be configured with the proper network settings to operate.INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
(Located on a label on the housing)2 CP# for Controller
NETWORK
Internet service provider:
Automatic IP addressing: DHCP (default setting)
OR
Static IP Addressing: Optional, requires connection to PC with USB (NOTE: Write down the following for future reference: IP, Netmask, Gateway, Primary, Secondary, Server Port)
3 Setup a LiftMaster Cloud AccountNOTE: If you have an existing MyQ account, your LiftMaster Cloud account will have the same password.1. If you do not have a LiftMaster Cloud Account, call LiftMaster Customer Care at 800.323.2276 to
activate a LiftMaster Hosted Cloud Service account.2. You will get a welcome email from LiftMaster. Accept the email invitation and register or login to
your account.3. Set up the Facility and add residents and credentials (refer to the available Help in LiftMaster
Cloud).4. Continue with the installation of the CAP2D in this manual.
CP# IPC-XX-XXXXXIPC - _ _ - _ _ _ _ _
For LiftMaster Cloud programming please visit www.LiftMasterCloud.com.
-
9
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
4 Mount the Bracket1. Install an electrical box in the desired mounting location.NOTE: Use 4" square electrical box (minimum of 1 1/2" deep) with a single-gang plaster ring. Use Wiremold V5744S or
BW35 for surface-mount installations.2. Remove the bracket from the back of the CAP2D. 3. Mount the bracket to the electrical box.4. Run all wiring to the electrical box.5. Once all the wiring is completed, position the CAP2D in the bracket and secure it at the bottom with the provided screw.
Bracket
Electrical Box
-
10
DO NOT connect a DC power supply if Power Over Ethernet (PoE) is selected and connected. Board may be damaged and is NOT covered under the warranty
Connect Power1
DO NOT power electronic strikes and latches with the same power supply used to power the access control panel; doing so will cause DAMAGE to the controller. Use ONLY a UL listed burglar alarm or access control system to power electronic strikes and latches.
DO NOT connect the power supply to a switched outlet or otherwise controlled AC outlet.
DO NOT connect the power supply to the 120 Vac outlet until ALL wiring is completed.
Install the transient noise suppression device (MOV) supplied with the controller for AC powered devices and Diode for DC powered devices.
USING A DC POWER SUPPLY:
The outlet for the controller MUST be an external dedicated 120 Vac outlet located within 60 feet (18.3 m) cable run of the controller. This outlet is recommended to be wired back to its own 10 Amp minimum circuit breaker.
1. Connect 14-18 AWG wire to the stripped secondary DC output wires on the power supply. Black is negative and red is positive.
2. Connect the power supply wires to the +12IN- terminal block (red to + and black to -).
3. Plug the power supply into a 120 Vac outlet after all connections have been made.
USING PoE (POWER OVER ETHERNET):
1. Connect Ethernet cable to the Ethernet port on the control board.
2. Move PoE jumper to Power over Ethernet (PoE) setting.
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
WIRE SPECIFICATION MAXIMUM RUN DISTANCE14 AWG Up to 60 Feet (18.3 m)
16 AWG Up to 37 Feet (11.3 m)
18 AWG Up to 24 Feet (7.3 m)
PoE (Power Over Ethernet)
Jumper
Red = +
Black = -
LAN (Ethernet) Conector
-12IN+on Control Board
120 VacDedicated Outlet
Power Supply
Dedicated 10 Amp Minimum Circuit
Power Supply
Default
PoEJumper
NOTE: IP Door Controller is to be connected to UL Listed Commercial 294 or 603 Power Supply.
-
11
1 Connect InternetINTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
Connect with LANThe Local Area Network (LAN) port is a 10/100 Ethernet interface with an RJ45 jack for connecting the CAP2D to a hub, switch, or router in order to gain connectivity to the Internet. Use a straight, (i.e., non-crossover) Cat5, Cat5e, or Cat6 cable to connect to a local hub, switch or router. This type of cable is referred to as an Ethernet cable in this manual.
1. Connect an Ethernet cable from the hub, switch, or router to the LAN port on the Control Board. When connected properly, the green and amber LED on the Ethernet port will light/fl icker. If the green LED is not lit, check the connections on the controller and the Ethernet hub.
2. The default connection is DHCP, no additional confi guration is required. If a fi xed IP address is required for your setup, use the USB cable provided to connect the controller to a PC.
LANon Control Board
ModemRouter/Switch
Ethernet Cable(325 feet [99.1 m] maximum)
11
Static IP (Optional)LiftMaster recommends the CAP2D be used in Dynamic IP (DHCP) mode, but it can be set to Static IP if required.
1. Connect the CAP2D to your laptop using the included USB connector. Connect power to the CAP2D using either a router/switch capable of providing Power Over Ethernet (POE) or the included power supply. If using the included power supply, move the POE jumper.
2. Install USB drivers a. If using Windows Vista/7/10 b. Navigate to Computer c. Right click on LiftMaster CAP2D Resources d. Click on the Driver folder e. Click on the LiftMasterCAP2DDriverSupport f. Allow the setup program to use administrative
privileges g. Click Next h. Accept any warning dialogs i. Click Finish j. After Installation, a message will display asking
you to reboot the PC. You may select Reboot Later.
k. Remove the USB Cable from the PC and wait for the PC to acknowledge removal.
3. Set static IP address: a. Next Reinsert the USB cable into the PC and wait
for the PC to acknowledge the device. b. Open your browser and enter the address
http://192.168.207.1 to access the Administrator Interface.
c. The login page displays: d. The login is cli. e. The password is new5cli. f. Click on the Networking tab. g. Click IP Confi guration. h. Click the Deactivate DHCP button. i. Fill in the fi elds according to the IT staff. j. Click Set Static Parameters. Changes have been
saved.4. How to return to DHCP Confi guration a. Open your browser and enter the address
http://192.168.207.1 b. The login page displays: c. The login is cli d. The password is new5cli. e. Click Networking tab. f. Click IP Address Confi guration. Click the Activate
DHCP button.5. To verify connectivity: a. Open LiftMaster Cloud b. Add the CAP2D to a facility and confi rm status is
Online
-
12
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
Admin Mode
Wiring REX (Request-to-Exit) and Doors/LiftMaster Gate Operators
1. Connect a laptop to the CAP2D ADMIN USB port on the unit using a standard USB Mini-B cable.
a. The CAP2D ADMIN port is a USB interface for connecting the CAP2D unit to a laptop or PC to gain access to the local administrative interface for debug and manual confi guration utilities.
b. The port requires a USB Mini-B cable for access between the laptop and the CAP2D unit.
1. Wire the REX and DOOR terminal block.
a. Connect the Normally Open (NO) contacts of the REX device to the REX and COM terminals.
When the switch closes, it initiates a Request-to-Exit (REX) program sequence, including the option to activate the door or other relays, fi re and door strike, and suppress any Door Forced messages.
b. Connect the Normally Closed (NC) contacts of the Door Sensor to the COM and CONTACT terminals.
In this context, an NC switch is considered closed when the door is closed (magnet present), and open when the door is open (no magnet is present).
When the switch is open, the control panel interprets this input as a Door Open condition. When the switch is closed, the control panel interprets this input as a Door Closed condition.
This circuit provides door status information (open/closed) to the control panel so LiftMaster Cloud can take appropriate action locally, or send email notifi cations if necessary.
2. Wire the DOOR LOCK RELAY terminal block.
a. Connect the door latch to the COM terminal and either the NO or NC terminal.
b. The DOOR LOCK RELAY provides both NO (Normally Open) and NC (Normally Closed) contacts, and is driven in response to the presentation of valid credentials or the programmable REX input.
c. Timing and other aspects of relay activation are programmed through LiftMaster Cloud.
3. If used for an alarm shunt, wire the AUX RELAY 1 terminal block. If not used for an alarm shunt, AUX RELAY 1 can be used for a variety of purposes.
4. Wire AUX RELAY 2. Like the AUX RELAY 1, this terminal block can be used for a variety of purposes.
NOTE: The fully programmable AUX RELAYs provide both NO (Normally Open) and NC (Normally Closed) contacts.
There is a 3 AMP 24 Volt DC limit on through current for ALL relays.
-
13
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
5. Wire the Reader switches to the Wiegand Input of terminals in this door node.
As of the drafting of this manual, the following readers have been tested by the Underwriters Laboratories for use with this equipment:
HID ProxPoint Plus
HID Thinline II
HID iClass RPK40CKNN
HID iClass R10CKNN
XCEEDID X1050B-B READER
LiftMaster KPR2000
NOTE: Refer to the Wiring Guide provided with the Reader/Keypad for connection diagrams.
a. Use the wire recommended by the manufacturer of the reader or keypad. If no wire is recommended, use a minimum of 22 AWG wire with suffi cient conductors that include shield (drain).
b. The reader interface uses standard Wiegand wiring conventions. Connect the wire properly to the terminal block on the appropriate board node. Following is a typical, but not universal, wiring guide. Refer to the Wiring Guide provided with the Reader/Keypad for guidelines related to your specifi c reader or keypad.
Connect the green reader wire to the DATA0 terminal. This is the standard Data 0 circuit for Wiegand readers.
Connect the white reader wire to the DATA1 terminal. This is the standard Data 1 circuit for Wiegand readers.
Connect the black reader wire to the GND terminal. This is the standard Ground circuit for the reader.
Connect the blue reader wire to the BUZZ terminal. This is the standard Buzzer circuit for the reader.
Connect the red reader wire to the 12VDC terminal. This provides +12VDC to power the reader.
Connect the orange reader wire to the GRN LED terminal. This is the green LED circuit.
Connect the brown reader wire to the RED LED terminal. This is the red LED circuit.
6. Install MOVs.
a. For LiftMaster Gate operators, install the MOV across the NC and Common terminals, as close as possible to the electric strike or latch. This will normally be at the connection from the fi eld-installed wiring to the pigtail or screw terminals of the electronic strike or latch.
b. Use the wire recommended by the manufacturer of the electric strike or latch. If no wire is recommended, use a minimum of 18 AWG wire with suffi cient strands for the specifi c electronic strike or latch.
Wiring REX and Doors/LiftMaster Gate Operators (continued)
Install the transient noise suppression device (mov) supplied with the control panel.
-
14
PRE-INSTALL NETWORKWIRING ACCESS CONTROLINTRODUCTION INSTALL
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
Operation
Normal Standby Operation: The CAP2D is always in ready state and is monitoring its inputs for changes. If any of the inputs change state, the CAP2D responds locally and communicates the change to LiftMaster Cloud.
Reader/Keypad Operation: The CAP2D is designed to work with an approved reader and keypad using standard 26 bit Wiegand format. Some keypads may use ASCII format to pass Entry Codes.
Refer to the wiring diagram for physical connection to the CAP2D. Refer to the reader and keypad manual for full operating instructions.
Access Granted/Access Denied: When a valid credential is presented, access is granted with no audio or visual feedback from the CAP2D. Some accessory devices may provide feedback. E.g., a card reader or receiver may beep or change colors of an LED to convey the status.
Maintenance and Testing: No periodic maintenance or testing is required for the product to maintain safe normal operation.
-
15
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
Gate AccessDisconnect power BEFORE making electrical connections. Below is an example of a wiring setup for gate access. Gate access can be wired to Door 1 or 2.
NOTE: Power Supplies shall be UL Listed Commercial 294 or 603 power limited output Power Supplies.
LAN
AD
MIN
DRY
RLY1
WET
PSE1
PoE
DRY
WET
RLY2
HRT
BT
REA
DER
1IO
1
REX
COM
DO
OR
RED
GRN
12V
BU
Z
GN
D
D1
D
0
IO
2
REX
COM
DO
OR
REA
DER
2
RED
GRN
12V
BU
Z
GN
D
D1
D
0
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
-12I
N+
+-
RFID ANTENNA KEYPAD
REQUEST TO EXITPRIMARY RELAY
AUXILIARY RELAY
WIEGANDREADER
PUSHBUTTONGATE OPERATOR
EXTERNAL FREE EXITLOOP DETECTOR
OR OR
OR
NOTES: The length of the unshielded
wires should be kept to a minimum to avoid electrical noise.
When extending the reader connection, the shield wire must be connected to an earth ground bus, but should NEVER be connected at the reader.
NOTE: Power supply forRFID antenna is not provided. DO NOT use the power supply for the door controller.
NOTE: For KPR2000 keypadwire the pink and black (ground)wires together.
RED
LED
- bro
wn
GREE
N LE
D - o
rang
e
DATA
1 -
whi
te
DATA
0 -
gree
n
GROU
ND -
blac
k
12Vd
c - r
ed
COM
REX
OPEN
COM
COM
NONC
Common(Exit Input)
Model MG1300
NORMALLY CLOSEUse 18-22 AWG
COMMON
Power for Maglock (Not Provided) DO NOT use the power supply for the controller
For AC Power: Install a Siemens S10K30MOV(Metal Oxide Varistor) (provided) or equivalent
For DC Power: Install a 1N4005 diodeor equivalent
-
16
RFID ANTENNA
WIEGAND
REQUEST TO EXIT
READER
PUSHBUTTON
PROXIMITYSENSOR
KEYPAD
MAGLOCK
LIGHTALARM BYPASS
OR OR
OR
OR
OR
DOOR STRIKE
RED
LED
- bro
wn
GREE
N LE
D - o
rang
e
DATA
1 -
whi
te
NEUT
RAL
DATA
0 -
gree
n
GROU
ND -
blac
k
12Vd
c - r
ed
PRIMARY RELAY
AUXILIARY RELAY
Model MG1300
Model HES(RS) 1006CLB(R)
NORMALLY CLOSE
Use 18-22 AWG
Use 18-22 AWG
COMMON
NORMALLY OPEN
NORMALLY OPEN
COMMON
COMMON
NCCOM
COM
LOAD
LINE
IsolationRelay
LowVoltagePowerSupply
NO
NO COMNO COM
NO
Power for Maglock (Not Provided) DO NOT use the power supply for the controller
Power for Maglock (Not Provided) DO NOT use the power supply for the controller
For AC Power: Install a Siemens S10K30MOV(Metal Oxide Varistor) or equivalent
For AC Power: Install a Siemens S10K30MOV(Metal Oxide Varistor) or equivalent
For DC Power: Install a 1N4005 diodeor equivalent
For DC Power: Install a 1N4005 diodeor equivalent
COM
REX
NOTES: The length of the unshielded
wires should be kept to a minimum to avoid electrical noise.
When extending the reader connection, the shield wire must be connected to an earth ground bus, but should NEVER be connected at the reader.
NOTE: Power supply forRFID antenna is not provided. DO NOT use the power supply for the door controller.
NOTE: For KPR2000 keypadwire the pink and black (ground)wires together.
NOTE: DO NOT run high voltage power within the CAP2D enclosure. This configuration has not been evaluated by UL. Use UL Listed Power Limited Power Supplies and UL Listed Isolation Relays.
Door AccessDisconnect power BEFORE making electrical connections. Below is an example of a wiring setup for door access. Door access can be wired to Door 1 or 2.
NOTE: Power Supplies shall be UL Listed Commercial 294 or 603 power limited output Power Supplies.
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
-
17
INTRODUCTION PRE-INSTALL NETWORKWIRING ACCESS CONTROL INSTALL
1 Install the CAP2D1. Make sure all the wiring is tucked into the electrical box.2. Slide the CAP2D onto the bracket and secure with the screw.NOTE: The control units shall be mounted in a protected area. The exit device REX and wiring must be contained within the secured area.
For LiftMaster Cloud programming please visit www.LiftMasterCloud.com.
Validate Proper Operation: Test each credential type and ensure proper behavior of each gate/door connected to CAP2D. Valid credentials and Request to Exit inputs should trigger the relay. Go to LiftMasterCloud.com for programming and to check CAP2D activity and status.
TroubleshootingCAP2D does not power on after connecting 12VDC transformer.
Check position of PoE jumper. Move jumper to the top position.
Relay does not trigger when a credential is presented.
Check power; are LEDs powered on? Check input devices and connections for proper operation. Check LiftMaster Cloud activity log to aid in diagnosing.
I received an email saying the CAP2D was offl ine.
Check LiftMaster Cloud for latest online/offl ine status. If still offl ine check local Internet connection and power to the CAP2D. Sometimes this is also triggered during regular maintenance on the LiftMaster Cloud Servers. CAP2D stores the database locally and continues to provide access control without an Internet connection. Activity and database changes are only exchanged with LiftMaster Cloud when CAP2D is online.
-
18
Confi guration SheetRecord device information and confi guration settings below.
Controller Name:NOTE: Any user of the system is subject to the terms outlined in the product EULA.
Notes:
DEVICE CONFIGURATION:
DOOR 1 DOOR/GATE NAME:
INPUTSWIEGAND REX STATUS
EOL (Y / N)
OUTPUTSPRIMARY RELAY AUXILIARY RELAY
N.O. N.C. N.O. N.C.
Notes:
DOOR 2 DOOR/GATE NAME:
INPUTSWIEGAND REX STATUS
EOL (Y / N)
OUTPUTSPRIMARY RELAY AUXILIARY RELAY
N.O. N.C. N.O. N.C.
Notes:
-
Legal DisclaimersFederal Communications Commission (FCC) Compliancy This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation or when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Increase the distance between the equipment and receiver. Connect the equipment to a circuit other than the one to which the receiver is connected. Consult the dealer for help.Canada-Underwriters Laboratories (C-UL) CompliancyFor C-UL Listed applications, the controller shall be installed in accordance with Part 1 of the Canadian Electrical Code.Documentation Disclaimer and RestrictionsInformation in this document is subject to change without notice and does not represent a commitment on the part of LiftMaster. For the most up-to-date information, visit www.LiftMaster.com.This document and the data herein shall not be duplicated, used or disclosed to others for procurement or manufacturing, except as authorized with the written permission of LiftMaster. The information contained within this document or within the product itself is considered the exclusive property of LiftMaster. All information in this document or within the hardware and software product themselves is protected by the copyright and/or other intellectual property laws of the United States.UL 294 Access Control Unit Level 1 (Attack, Endurance, Line Security, Standby)
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifi cations of this digital device are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifi cations not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC rules and IC License-Exempt RSS Standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.This Class B digital apparatus complies with Canadian ICES-003.This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.- Consult the dealer or an experienced radio/TV technician for help.- This device must be installed in a way where a minimum 8" (20 cm) distance is maintained between users/bystanders and device.
WarrantyLiftMaster (Seller) warrants to the fi rst purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase.The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806 before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty replacement. Products returned to Seller for warranty replacement, which upon receipt by Seller are confi rmed to be defective and covered by this limited warranty, will be replaced (at Sellers sole option) at no cost to you and returned pre-paid. Defective parts will be replaced with new or factory-rebuilt parts at Sellers sole option.THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, AND OF ANY OTHER OBLIGATIONS OR LIABILITY ON SELLERS PART. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, PROBLEMS RELATED TO INTERFERENCE, OR REPLACEMENT OF BATTERIES.UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLERS LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state.
All trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
2017 LiftMaster All rights reserved.114A4982
-
Contrleur de 2 portes portail daccs connect
LiftMaster CloudTM
MANUEL DINSTALLATION
Mod
le
CA
P2D
-
2
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
INTRODUCTIONScurit ......................................................................... 3Prsentation du contrleur ............................................ 4Prsentation du tableau de commande ......................... 4Contenu de lemballage ................................................. 5Outils ncessaires ......................................................... 5Dimensions .................................................................. 5Caractristiques techniques .......................................... 6Caractristiques lectriques .......................................... 6Caractristiques techniques du cblage ........................ 7
PRINSTALLATIONService Internet ............................................................. 8No CP pour contrleur ................................................... 8Confi guration dun compte LiftMaster Cloud ................. 8Montage du support ...................................................... 9
CBLAGEConnecter lalimentation .............................................. 10
RSEAU
Connecter lappareil Internet..................................... 11
CONTRLE DACCSMode Admin ................................................................ 12Cblage des dispositifs REX et des portes .................. 12Opration .................................................................... 14Accs la barrire ....................................................... 15Accs la porte ........................................................... 16
Fiche de confi guration................................................ 18Avis lgaux ................................................................. 19Garantie ...................................................................... 19
1
2
3
4
INSTALLATION5Installer le du CAP2D .................................................. 17Dpannage .................................................................. 17
Pour la programmation LiftMaster Cloud, aller www.LiftMasterCloud.com.
-
3
Pour rduire le risque de BLESSURES GRAVES, voire MORTELLES: Dconnecter lalimentation au niveau de la bote fusibles
AVANT de poursuivre. Pour VITER dendommager les conduites de gaz, les lignes
lectriques ou autres conduites de services publics, contacter les compagnies de localisation de services souterrains AVANT dentreprendre les travaux dexcavation.
TOUTES les connexions lectriques doivent tre effectues par une personne qualifie.
Tout le cblage dalimentation et de commune DOIT tre achemin dans un conduit spar.
Pour protger contre lincendie ou llectrocution: Dconnecter lalimentation AVANT dinstaller ou deffectuer
une intervention dentretien sur le contrleur. NE JAMAIS connecter un clavier/lecteur ou une serrure aux
portes sans dabord consulter le code de prvention des incendies applicable.
Il est IMPRATIF de consulter les autorits du service local des incendies et dobtenir leur approbation AVANT dinstaller des serrures ou des dispositifs TOUTE porte qui pourrait servir de sortie de secours en cas dincendie.
Il est possible que lutilisation de boutons-poussoirs pour une porte de secours ne soit pas lgale. Des sorties de secours action unique peuvent tre exiges.
TOUJOURS obtenir les permis et autorisations appropris AVANT dinstaller un quipement quelconque.
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENTAVERTISSEMENT
ScuritExamen des symboles de scurit et des mots de signalement Les symboles de scurit et mots de signalement qui fi gurent sur les pages suivantes avisent le lecteur de la possibilit de blessures graves ou de mort en cas de non-conformit aux avertissements qui les accompagnent. Le danger peut tre de source mcanique ou provenir dune dcharge lectrique. Lire attentivement les avertissements.
Ce mot indicateur sur les pages suivantes alerte le lecteur de la possibilit de dommages la porte ou au dispositif de fermeture en cas de non-conformit aux avertissements laccompagnant. Prire de les lire attentivement.
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
MCANIQUE
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
LECTRIQUE
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
HOMOLOGATION DES UNDERWRITERS LABORATORIES (UL)Le CAP2D est conforme la norme UL294 des units de contrle daccs avec les restrictions suivantes: Les contacts du systme de relais ne doivent pas tre
confi gurs en mode de scurit intgre moins que les autorits locales comptentes ne lautorisent et que cela ne nuise pas au fonctionnement des barres antipanique.
Le port Ethernet est rserv uniquement un usage supplmentaire et lunit continuera fonctionner delle-mme si la connexion au rseau est interrompue.
Cette unit peut tre alimente par Ethernet au moyen dun matriel compatible PoE. Si une source dalimentation PoE est utilise, elle doit tre homologue UL294.
Tous les dispositifs dinterconnexion doivent tre homologus UL.
NE PAS INSTALLER LE SYSTME EN MODE DE SCURIT INTGRE MOINS QUE LES AUTORITS LOCALES COMPTENTES NE LAUTORISENT. Cela pourrait causer une interfrence avec le fonctionnement de la serrure coup de poing.
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT : Ce produit peut vous exposer des substances chimiques, incluant du plomb, lesquelles sont reconnues par ltat de la Californie comme tant cancrignes et pouvant causer des anomalies congnitales ou autres prjudices lappareil reproducteur. Pour plus dinformation, aller www.P65Warnings.ca.gov
-
4
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
Prsentation du contrleur
Prsentation du tableau de commande
DEL DU RSEAU DEL orange: Lien 100MBitDEL bleu: Activit du rseauDEL bleu de droite: Bonne connexion au rseau
DEL ACTIVETEINTE/En continu: Le systme dmarre
Clignotante: Le systme est fonctionnel.Diode dtatEn continu: Le systme est sous tension
Connexion du tableau de commande
Description
USB administratif Connecter par mini-USB pour accder ladministration
LAN/PoE Connecter au rseau. Peut aussi avoir une alimentation 802.3af/at.
Pile de secours au Lithium La batterie prserve les donnes du systme pendant les pannes de courant primaires.
tat de sant local La DEL indique une fonction adquate.
Tmoin de relais La DEL sallume quand le relais est engag (une par relais)
Confi guration de lalimentation Slections de liaison entre lalimentation par cble Ethernet et lalimentation auxiliaire
VUE AVANT
LAN
AD
MIN
DRY
RLY1
WET
PSE1
PoE
DRY
WET
RLY2
HRT
BT
REA
DER
1IO
1
REX
COM
DO
OR
RED
GRN
12V
BU
Z
GN
D
D1
D
0
IO
2
REX
COM
DO
OR
REA
DER
2
RED
GRN
12V
BU
Z
GN
D
D1
D
0
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
-12I
N+
USB DADMINISTRATION
PORT
E1
PORT
E2
Relais auxiliare1
TAT DE DEMANDE DE SORTIE
ENTRE WIEGAND
TAT DE DEMANDE DE SORTIE
ENTRE WIEGAND
CAVALIER DE CONFIGURATION DE LALIMENTATION
ALIMENTATION 12V EXTERNE
PILE BOUTON DE SECOURS AU LITHIUM (CR1220)
Connecteur LAN / PoE
DEL DTAT DE SANT LOCAL
Relais primaire 1
Relais auxiliare2
Relais primaire 2
-
5
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
Contrleur de porte Cble USB Diodes Manuel dinstallation
Contenu de lemballage
Outils ncessaires Tournevis cruciforme PH2 Tournevis tte plate de prcision 1/8po ou cruciforme PH0 Tournevis douille 1/4 po Perceuse/tournevis lectrique Mche de 7/64po Embouts pour marteau pour perceuse/tournevis lectrique Pinces sertir RJ45 Multimtre Ruban mesurer Cintreuse de tuyaux rigides Alsoir/coupe-tuyau Scie mtaux Pointeau Marteau
Dimensions
11,4cm (4 1/4po)
7,6cm (3po)3,2cm (11/4po)
0,9cm (0,36po)
-
6
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
Spcifi cationsCapacit du CAP2D Personnes: 25000, vnements: 8000Plages de tempratures de service du CAP2D 0C 49C (32F 125F) Humidit de service du CAP2D 5 % 95 % sans condensationPlage de tempratures de rangement et dexpdition
-40C 65C (-40F 149F)
Entres Wiegand (2) 26bits, 30bits. Le CAP2D est compatible avec les dispositifs Wiegand qui transmettent jusqu 255 bits de donnes
2sorties relais primaires et 2auxiliaires SPDTCompatibilit des accessoires Consulter la page des accessoires cet effet.Compatibilit du rseau 10/100/1 000 EthernetCaractristiques du cblage thernet cbl RJ-45
Caractristiques lectriquesENTRE
DALIMENTATIONTENSION ALIMENTATION
(MIN)Entre auxiliaire 12V c.c. 13WAlimentation par cble Ethernet
45-57 V c.c. 13W
SORTIE DALIMENTATION
TENSION COURANT (MAX)
Relais (mouill) 12 V c.c. 750mA (combin)Lecteurs Wiegand 12 V c.c. 750mA (combin)
Relais (sec- inductif) 30 Vc.c.(max) 2000mA
REMARQUE : Le contrleur de porte doit tre connect une alimentation homologation UL commerciale 294 ou 603 pour une source auxiliaire, ou homologation UL 294/294b PoE pour une source Ethernet.
-
7
Caractristiques techniques du cblageUtiliser ce tableau pour tirer les fils en prparation de votre installation.
DESCRIPTION DU FILAGE SPCIFICATION DE CBLAGE DISTANCE MAXIMALE DU FILAGEFil lectrique, sortie c.c. secondaire 2 conducteurs 14AWG
2 conducteurs 16AWG 2 conducteurs 18AWG
Jusqu 18,3m (60pi)Jusqu 11,3m (37pi)Jusqu 7,3m (24pi)
Rseau local ( LAN ) CAT 5/6 cble de rseau
8conducteurs, paires torsades 24AWG 100*m (328pi)
Barre antipanique/actionneur de barrire LiftMaster
2conducteurs, blind 18 22AWG 30,5 76,2m (100 250pi)
Verrouillage magntique 2conducteurs, 18 22AWG 15,2 38,1m (50 125pi)
Fermeture contact sec (la plupart des actionneurs)
2conducteurs, blind 18 22AWG 152,4 762m (500 2 500pi)
Demande de sortie (REX) 2conducteurs, 18 22AWG 152,4m (500 pi)
Entre supervise 2conducteurs, 18 22AWG 152,4m (500 pi)
Lecteurs Wiegand/de proximit 7conducteurs, blind 18 22AWG 152,4m (500 pi)
REMARQUE: Les fils dalimentation et de commande DOIVENT passer dans des conduits distincts. Les conduits doivent tre homologusUL pour faibles et hautes tensions. Consulter le NEC et la norme ANSI/NFPA 70 pour les exigences de cblage supplmentaires.
REMARQUE: Placer le CAP2D moins de 152mtres (500pieds) de la barre antipanique ou de la serrure coup de poing qui lui est associ. Le logiciel de surveillance nest pas valu par lUL.
Fournir toujours une alimentation dune source rserve cet effet. Brancher le transformateur fourni dans une prise cble son propre disjoncteur de 10A au minimum. Cela permet de prvenir deux problmes: Un autre quipement ne pourra pas introduire dans le circuit dalimentation du bruit, des pointes ou chutes de tension ou des
surtensions qui compromettraient le systme. Le fonctionnement du systme ne sera pas touch si tout autre quipement dveloppe un court-circuit dans la ligne lectrique.
* REMARQUES CONCERNANT LE CBLE DE RSEAU CAT 5/6: Pour les distances extrieures dpassant 42,7m (140pi), un limiteur de tension primaire conforme la normeUL497 DOIT tre
install au niveau du contrleur. Des articles de quincaillerie supplmentaires peuvent tre utiliss pour les distances dpassant 100m (328pi). Contacter le service
dassistance technique pour plus dinformation. Les articles de quincaillerie supplmentaires nont pas t valus en vertu de la norme UL294.
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
-
8
1 Service InternetLe contrleur DOIT tre configur laide des bons paramtres de rseau pour fonctionner.PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
(Situ sur une tiquette sur le botier)2 No CP pour contrleur
RSEAU
Fournisseur de service Internet:
Adressage IP automatique: DHCP (paramtre par dfaut)
OU
Adressage IP statique: optionnel, exige une connexion un ordinateur avec USB (REMARQUE: Noter les renseignements suivants pour rfrence ultrieure: IP, masque, passerelle, primaire, secondaire, port du serveur)
3 Confi guration dun compte LiftMaster CloudREMARQUE: Si un compte MyQ a dj t cr, le compte LiftMaster Cloud utilisera le mme mot de passe.1. Si aucun compte LiftMaster Cloud na t cr, appeler lassistance la clientle au 800323.2276
pour activer un compte LiftMaster de service hberg dans linfonuagique.2. Un courriel de bienvenue de LiftMaster vous sera envoy. Accepter linvitation par courriel et
vous connecter ou vous connecter au compte.
3. Confi gurer linstallation et ajouter les rsidents et les identifi ants (consulter laide disponible dans LiftMaster Cloud).
4. Poursuivre avec linstallation du CAP2D avec ce manuel.
CP# IPC-XX-XXXXXIPC - _ _ - _ _ _ _ _
Pour la programmation LiftMaster Cloud, aller www.LiftMasterCloud.com.
-
9
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
4 Montage du support1. Installer un coffret de branchement lemplacement de montage dsir.REMARQUE: Se servir dun coffret de branchement carr de 10cm (4po) (dune profondeur minimale de 3,8cm ou 11/2po)
avec un anneau pltre simple. Utiliser Wiremold V5744S ou BW35 pour les installations montes en surface.2. Enlever lagrafe larrire du CAP2D. 3. Monter le support au coffret de branchement.4. Acheminer tous les fi ls au coffret de branchement.5. Lorsque tout le cblage est complt, positionner le CAP2D dans le support et le fi xer au bas avec la vis fournie.
Support
Coffret de branchement
-
10
NE PAS connecter une alimentation c.c. si lalimentation par cble Ethernet (PoE) a t slectionne et connecte. Le circuit risque dtre endommag et ne sera PAS couvert par la garantie
Connecter lalimentation1
NE PAS alimenter les barres antipanique et les loquets laide de la mme source dalimentation que celle utilise pour le panneau de contrle daccs; une telle faon de faire causera des DOMMAGES au contrleur. Utiliser UNIQUEMENT une alarme anti-cambriolage ou un systme de contrle daccs homologu UL pour alimenter les barres antipanique et les loquets lectroniques.
NE PAS raccorder lalimentation lectrique une prise commute ou autrement contrle par une prise c. a.
NE PAS raccorder lalimentation lectrique une prise de 120V c. a. jusqu ce que TOUT le cblage ait t effectu.
Installer le dispositif de suppression du bruit transitoire (varistance) fourni avec le contrleur pour les dispositifs aliments par courant alternatif et une diode pour les dispositifs aliments par courant continu.
AVEC UNE SOURCE DALIMENTATION C.C.:La prise du contrleur DOIT tre une prise externe rserve de 120V c.a. situe moins de 18,3m (60pi) de fi lage du contrleur. Cette prise doit tre cble son propre disjoncteur de 10A au minimum.
1. Connecter le fi l 14-18AWG aux fi ls dnuds de sortie de courant c.c. secondaire sur la source dalimentation lectrique. Le noir est ngatif et le rouge est positif.
2. Connecter les fi ls dalimentation lectrique au bornier +12IN- (rouge + et noir -).
3. Brancher le transformateur dans une prise de 120V c.a. lorsque toutes les connexions ont t effectues.
PAR PoE (ALIMENTATION PAR CBLE ETHERNET):1. Connecter le cble Ethernet au port Ethernet sur le tableau de
commande.
2. Dplacer le cble de liaison PoE au paramtre dalimentation par cble Ethernet.
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
SPCIFICATION DE CBLAGE DISTANCE MAXIMALE DU FILAGE14 AWG Jusqu 18,3m (60pi)
16 AWG Jusqu 11,3m (37pi)
18 AWG Jusqu 7,3m (24pi)
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
PoE (Power Over Ethernet)
Liaison
Rouge = +
Noir = -
Connecteur LAN (Ethernet)
-12IN+sur le tableau de
commande
Prise de 120V c.a. rserve
Alimentation lectrique
Circuit rserv de 10A minimum
Alimentation lectrique
Rglage par dfaut
PoELiaison
REMARQUE: Le contrleur de porte IP doit tre connect une alimentation dhomologation commerciale UL 294 ou 603.
-
11
1 Connecter lappareil InternetPRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
Connexion au rseau LANLe port du rseau local (LAN) est une interface Ethernet 10/100 dote dun connecteur RJ45 pour la connexion du CAP2D un concentrateur afi n dobtenir une connectivit Internet. Utiliser un cble direct (c.--d. pas de cble de relais) ) Cat5, Cat5e ou Cat6 pour raccorder ce port un concentrateur local, un commutateur ou un routeur. On fait rfrence ce type de cble comme tant un cble Ethernet dans ce manuel. 1. Connecter un cble Ethernet partir du concentrateur, du
commutateur ou du routeur au port LAN sur le tableau de commande. Lorsque la connexion a bien t tablie, la DEL verte et la DEL ambre sur le port Ethernet sallumeront/clignoteront brivement. Si la DEL verte ne sallume pas, vrifi er les connexions sur le contrleur et le concentrateur Ethernet.
2. La connexion par dfaut est DHCP, aucune autre confi guration nest ncessaire. Si une adresse IP fi xe est ncessaire pour votre confi guration, utiliser le cble USB fourni pour connecter le contrleur un ordinateur.
LAN sur le tableau de commande
ModemRouteur/commutateur
Cble Ethernet(99,1 m [325 pi] maximum)
11
IP statique (en option)LiftMaster recommande que le CAP2D soit utilis en mode dIP dynamique (DHCP), mais il peut tre rgl une IP statique au besoin.
1. Connecter le CAP2D un ordinateur avec le connecteur USB fourni. Connecter lalimentation au CAP2D avec un routeur/commutateur capable de fournir une alimentation par cble Ethernet (PoE) ou avec la source dalimentation fournie. Si la source dalimentation fournie est utilise, dplacer le cavalier PoE.
2. Installation des pilotes USB a. Si Windows Vista/7/10 est utilis b. Naviguer jusqu Computer (Ordinateur) c. Cliquer droite sur LiftMaster CAP2D Resources (Ressources CAP2D LiftMaster) d. Cliquer sur le dossier Driver (Pilote) e. Cliquer sur LiftMasterCAP2DDriverSupport f. Permettre au programme de confi guration
dutiliser les privilges administrateurs. g. Cliquer sur Next (Suivant) h. Accepter tout dialogue davertissement i. Clique sur Finish (Termin) j. Aprs linstallation, un message saffi chera
demandant de redmarrer lordinateur. Il est possible de slectionner Reboot Later (Redmarrer plus tard)
k. Enlever le cble USB de lordinateur et attendre que lordinateur reconnaisse le retrait.
3. tablir ladresse IP statique: a. Rinsrer ensuite le cble USB dans lordinateur et
attendre que ce dernier reconnaisse le dispositif. b. Ouvrir le navigateur et saisir ladresse
http://192.168.207.1 pour accder linterface administrateur.
c. La page daccueil saffi che: d. L identifi ant est cli. e. Le mot de passe est new5cli. f. Cliquer sur longlet Networking (Mise en rseau). g. Cliquer sur IP Confi guration (Confi guration IP). h. Cliquer sur le bouton Deactivate DHCP
(Dsactiver DHCP). i. Renseigner les champs selon les instructions du
personnel des TI. j. Cliquer sur Set Static Parameters (Rgler les
paramtres statiques). Les changements ont t enregistrs.
4. Comment retourner la confi guration DHCP a. Ouvrir le navigateur et saisir ladresse
http://192.168.207.1 b. La page daccueil saffi che : c. L identifi ant est cli. d. Le mot de passe est new5cli. e. Cliquer sur longlet Networking (Mise en rseau). f. Cliquer sur IP Address Confi guration
(Confi guration dadresse IP). Cliquer sur le bouton Activate DHCP (Activer DHCP).
5. Pour vrifi er la connectivit: a. Ouvrir LiftMaster Cloud b. Ajouter le CAP2D une installation et confi rmer
que ltat est Online (en ligne).
-
12
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
Mode Admin
Cblage de demande de sortie (REX) et des portes/actionneurs de barrire LiftMaster
1. Connecter un ordinateur portable au port USB ADMIN du CAP2D laide dun cble USB Mini-B standard.
a. Le port USB ADMIN du CAP2D est une interface USB permettant de relier le CAP2D un ordinateur portable ou un PC pour accder linterface administrative locale et profi ter des utilitaires de dbogage et de confi guration manuelle.
b. Le port ncessite un cble USB Mini-B pour fournir un accs entre lordinateur portable et le CAP2D.
1. Brancher le bornier des dispositifs REX et des PORTES.
a. Connecter les contacts normalement ouverts (NO) du dispositif REX aux bornes REX et COM.
Lorsque le commutateur se ferme, il lance une squence programme de demande de sortie (REX), incluant loption dactiver le relais de la porte ou dautres relais, dactionner le pne et supprimer tout message de Porte force.
b. Connecter les contacts normalement ferms (NC) du capteur de porte aux bornes COM et CONTACT.
Dans ce contexte, un commutateur normalement ferm est considr ferm lorsque la porte est ferme (laimant et prsent), et est considr ouvert lorsque la porte est ouverte (absence daimant).
Lorsque le commutateur est ouvert, le tableau de commande interprte cette entre comme une situation de Porte ouverte. Lorsque le commutateur est ferm, le tableau de commande interprte cette entre comme une situation de Porte ferme.
Ce circuit indique ltat de la porte (ouverte/ferme) au tableau de commande afi n que LiftMaster Cloud prenne la mesure approprie localement ou envoie des avis par courriel sil y a lieu.
2. Brancher le bornier du RELAIS DE SERRURE DE PORTE.
a. Connecter la serrure de la porte la borne COM et la borne NO ou NC.
b. Le RELAIS DE SERRURE DE PORTE offre la fois des contacts NO (normalement ouverts) et NC (normalement ferms) et est actionn en rponse la prsentation dun identifi ant valide ou dune entre REX programmable.
c. Le moment de lactivation et dautres aspects du relais sont programms au moyen de LiftMaster Cloud.
3. Sil est utilis pour une drivation dalarme, brancher le bloc de bornes RELAIS1 AUX. Sil nest pas utilis pour une drivation dalarme, le bloc de bornes RELAIS1 AUX peut servir une varit dutilisations.
4. Brancher le RELAIS2 AUX. Tout comme le RELAIS AUX1, ce bornier peut servir une varit dutilisations.
REMARQUE: Les RELAIS AUX sont entirement programmables et offrent la fois des contacts NO (normalement ouverts) et NC (normalement ferms).
Il existe une limite de 3A, 24V c.c. du courant de transit pour TOUS les relais.
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
-
13
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
5. Brancher le commutateur du LECTEUR lentre Wiegand des bornes dans ce nud de la porte.
Au moment de la rdaction de ce manuel, les lecteurs suivants ont t tests par Underwriters Laboratories comme convenant cet quipement:
HID ProxPoint Plus
HID Thinline II
HID iClass RPK40CKNN
HID iClass R10CKNN
XCEEDID X1050B-B READER
LiftMaster KPR2000
REMARQUE: Consulter le guide de cblage fourni avec le lecteur/clavier pour les schmas de raccordement.
a. Utiliser le fi l recommand par le fabricant du lecteur ou du clavier. Si aucun fi l nest recommand, utiliser un fi l de calibre 22 AWG au minimum avec suffi samment de conducteurs blinds (de drainage).
b. Linterface du lecteur utilise les conventions de branchement standard Wiegand. Connecter correctement les fi ls au bornier du circuit de nud appropri. Voici un guide de cblage type, mais non universel. Consulter le guide de cblage fourni avec le lecteur/clavier pour des consignes relatives votre lecteur ou clavier particulier.
Connecter le fi l vert du lecteur la borne DATA0. Il sagit du circuit Data 0 standard des lecteurs Wiegand.
Connecter le fi l blanc du lecteur la borne DATA1. Il sagit du circuit Data 1 standard des lecteurs Wiegand.
Connecter le fi l noir du lecteur la borne GND (terre ou masse). Il sagit du circuit de mise la terre standard du lecteur.
Connecter le fi l bleu du lecteur la borne BUZZ. Il sagit du circuit davertisseur (Buzzer) standard du lecteur.
Connecter le fi l rouge du lecteur la borne 12V c.c. Ce fi l fournit +12V c.c au lecteur.
Connecter le fi l orange du lecteur la borne GRN LED. Il sagit du circuit de la DEL verte.
Connecter le fi l brun du lecteur la borne RED LED. Il sagit du circuit de la DEL rouge.
6. Installer les varistances (MOV).
a. Pour les actionneurs de barrire LiftMaster, installer les varistances aux bornes NC et communes, aussi prs que possible de la barre antipanique ou de la serrure coup de poing. Elles sinstallent normalement sur la connexion venant du cblage du site sur les bornes visses ou en tire-bouchon du pne ou de la serrure lectrique.
b. Utiliser le fi l recommand par le fabricant du pne ou de la serrure lectrique. Si aucun fi l nest recommand, utiliser un fi l de calibre 18 AWG au minimum avec suffi samment de conducteurs pour brancher le pne ou la serrure lectronique.
Cblage du dispositif REX et des portes/actionneurs de barrire LiftMaster (suite) Installer le suppresseur de bruits (varistance oxyde mtallique - MOV)
fourni avec le tableau de commande.
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
-
14
Opration
Fonctionnement de veille normal : Le CAP2D est toujours prt lemploi et surveille ses entres pour dtecter tout changement. Si une entre quelconque change dtat, le CAP2D ragit localement et communique le changement LiftMaster Cloud.
Fonctionnement du lecteur/clavier : Le CAP2D a t conu pour fonctionner avec un lecteur et un clavier utilisant le format Wiegand standard de 26 bits. Certains claviers peuvent utiliser le format ASCII pour les codes dentre.
Consulter le schma de cblage pour la connexion physique au CAP2D. Consulter le manuel du lecteur et du clavier pour le mode demploi complet.
Accs accord/refus : Lorsquun identifiant valide est prsent, laccs est accord sans rtroaction audio ou visuelle du CAP2D. Certains dispositifs accessoires peuvent fournir une rtroaction. Par exemple, un lecteur de carte ou un rcepteur peut mettre un bip ou une DEL peut changer de couleur pour communiquer ltat du dispositif.
Entretien et mise lessai : Aucun entretien ou aucune mise lessai nest ncessaire pour que le produit maintienne un fonctionnement scuritaire normal.
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
-
15
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
Accs la barrireDconnecter lalimentation AVANT deffectuer des connexions lectriques. Un exemple de confi guration de cblage pour accs la barrire est prsent ci-dessous. Laccs la barrire peut tre cbl la porte 1 ou 2.
REMARQUE: Les sources dalimentation doivent tre des sources commerciales homologues UL 294 ou 603 sortie de puissance limite.
LAN
AD
MIN
DRY
RLY1
WET
PSE1
PoE
DRY
WET
RLY2
HRT
BT
REA
DER
1IO
1
REX
COM
DO
OR
RED
GRN
12V
BU
Z
GN
D
D1
D
0
IO
2
REX
COM
DO
OR
REA
DER
2
RED
GRN
12V
BU
Z
GN
D
D1
D
0
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
-12I
N+
+-
ANTENNE RFID CLAVIER
DEMANDE DE SORTIERELAIS PRIMAIRE
RELAIS AUXILIAIRE
WIEGANDLECTEUR
BOUTON-POUSSOIRACTIONNEUR
DE BARRIRE
BOUCLE DE DTECTIONEXTERNE DE SORTIE LIBRE
OU OU
OU
REMARQUES : La longueur des fils non blinds doit tre
minimale pour viter le bruit lectrique. En rallongeant la connexion du lecteur, le fil
blind doit tre connect un bus de mise la terre, mais ne doit JAMAIS tre connect au lecteur.
REMARQUE : Lalimentation lectrique nest pas fournie pour lantenne RFID. NE PAS utiliser lalimentation lectrique du contrleur de porte.
REMARQUE : Pour le clavier KPR2000, cbler le fil rose et les fils noirs (terre) ensemble.
DEL
ROUG
E - b
run
DEL
VERT
E -
oran
ge
DONN
ES
1 - b
lanc
DONN
ES
0 - v
ert
TERR
E - n
oir
12 V
c. c
. - ro
uge
COM
REX
OUVERT
COM
COM
NONC
Commun (entre de sortie)
Modle MG1300
NORMALEMENTFERM
Utiliser un fil decalibre 18 22 AWG
COMMUN
Alimentation pour serrure lectromagntique (non fournie) NE PAS utiliser lalimentation lectrique du contrleur
Pour une alimentation c.a. :Installer une varistance Siemens S10K30MOV(varistance oxyde mtallique) (fournie) ou son quivalent
Pour une alimentation c. c. : Installer une diode 1N4005 ou un produit quivalent
-
16
ANTENNE RFID
WIEGAND
DEMANDE DE SORTIE
LECTEUR
BOUTON-POUSSOIR
CAPTEUR DEPROXIMIT
CLAVIER
SERRURE LECTROMAGNTIQUE
CLAIRAGEDRIVATION DALARME
OU OU
OU
OU
OU
BARRE ANTIPANIQUE
DEL
ROUG
E - b
run
DEL
VERT
E -
oran
ge
DONN
ES
1 - b
lanc
NEUT
RE
DONN
ES
0 - v
ert
TERR
E - n
oir
12 V
c. c
. - ro
uge
RELAIS PRIMAIRE
RELAIS AUXILIAIRE
Modle MG1300
Modle HES(RS) 1006CLB(R)
NORMALEMENT FERM
Utiliser un fil de calibre 18 22 AWG
Utiliser un fil de calibre 18 22 AWG
COMMUN
NORMALEMENT FERM
NORMALEMENTFERM
COMMUN
COMMUN
NCCOM
COM
CHARGE
LIGNE
Relaisdisolation
Alimentation faibletension
NO
NO COMNO COM
NO
Alimentation pour serrure lectromagntique (non fournie) NE PAS utiliser lalimentation lectrique du contrleur
Alimentation pour serrure lectromagntique (non fournie) NE PAS utiliser lalimentation lectrique du contrleur
Pour une alimentation c.a. : Installer une varistance Siemens S10K30MOV (varistance oxyde mtallique) ou un produit quivalent
Pour une alimentation c.a. : Installer une varistance Siemens S10K30MOV (varistance oxyde mtallique) ou un produit quivalent
For DC Power: Install a 1N4005 diodeor equivalent
Pour une alimentation c. c. :Installer une diode 1N4005 ou un produit quivalent
COM
REX
REMARQUES : La longueur des fils non blinds doit tre
minimale pour viter le bruit lectrique. En rallongeant la connexion du lecteur, le fil
blind doit tre connect un bus de mise la terre, mais ne doit JAMAIS tre connect au lecteur.
REMARQUE : Lalimentation lectrique nest pas fournie pour lantenne RFID. NE PAS utiliser lalimentation lectrique du contrleur de porte.
REMARQUE : Pour le clavier KPR2000, cbler le fil rose et les fils noirs (terre) ensemble.
REMARQUES : NE PAS acheminer de fils dalimentation haute tension dans lenceinte du CAP2D. Cette configuration na pas t value par l'UL. Utiliser des sources dalimentation limites homologues par lUL et des relais disolation homologus par lUL
Accs la porteDconnecter lalimentation AVANT deffectuer des connexions lectriques. Un exemple de confi guration de cblage pour accs la porte est prsent ci-dessous. Laccs la porte peut tre cbl la porte 1 ou 2.REMARQUE: Les sources dalimentation doivent tre des sources commerciales homologues UL 294 ou 603 sortie de puissance limite.
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
-
17
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
PRINSTALLATION RSEAUCBLAGE CONTRLE D'ACCSINTRODUCCION CONTRLE D'ACCS
Bracket
Electrical Box
1 Installation du CAP2D1. Sassurer que tout le cblage est bien insr dans le coffret de branchement.2. Glisser le CAP2D sur le support et le fixer avec la vis.REMARQUE: Lunit de commande doit tre monte dans une zone protge. Le dispositif de demande de sortie (REX) et le cblage doivent tre contenus dans la zone protge.
1 SETUP 2 INSTALL 3 CONNECT 4 ADD DEVICES
1 SETUP 2 INSTALL
3 CONNECT 4 ADD DEVICES
Pour la programmation LiftMaster Cloud, aller www.LiftMasterCloud.com.
Validation du bon fonctionnement : Tester chaque type didentifiant et vrifier le bon comportement de chaque barrire/porte connecte au CAP2D. Des identifiants valides et les entres de demande de sortie devraient dclencher le relais. Aller LiftMasterCloud.com pour la programmation et la vrification de lactivit et de ltat du CAP2D.
DpannageLe CAP2D ne se met pas sous tension aprs avoir connect un transformateur de 12 V c. c.
Vrifier la position du cavalier PoE. Dplacer le cavalier la position suprieure.
Le relais ne se dclenche pas lorsquun identifiant est prsent.
Vrifier lalimentation, les DEL sont-elles allumes? Vrifier le bon fonctionnement des dispositifs et connexions dentre. Vrifier le journal dactivit LiftMaster Cloud pour aider tablir le diagnostic.
Jai reu un courriel minformant que le CAP2D ntait pas en ligne.
Vrifier LiftMaster Cloud pour prendre connaissance de ltat en ligne/hors ligne du dispositif le plus rcemment enregistr. Si le dispositif est hors ligne, vrifier la connexion locale Internet et lalimentation lectrique au CAP2D. Il arrive parfois que la maintenance rgulire des serveurs LiftMaster Cloud ait pour effet de dclencher ce message. Le CAP2D stocke la base de donnes localement et continue de fournir un contrle de laccs sans connexion Internet. Les changements dactivit et de la base de donnes ne sont changs avec LiftMaster Cloud que lorsque le CAP2D est en ligne.
-
18
Fiche de confi gurationNoter linformation sur lappareil et les paramtres de confi guration ci-dessous.
Nom du contrleur:REMARQUE : Tout utilisateur de ce systme est soumis aux conditions dcrites dans laccord dutilisation du produit.
Remarques:
CONFIGURATION DU DISPOSITIF :
PORTE1 NOM DE LA PORTE/BARRIRE:
ENTRESWIEGAND Demande de sortie (REX) TAT
EOL (O / N)
SORTIESRELAIS PRIMAIRE RELAIS AUXILIAIRE
N.O. N.C. N.O. N.C.
Remarques:
PORTE2 NOM DE LA PORTE/BARRIRE:
ENTRESWIEGAND Demande de sortie (REX) TAT
EOL (O / N)
SORTIESRELAIS PRIMAIRE RELAIS AUXILIAIRE
N.O. N.C. N.O. N.C.
Remarques:
-
AVIS LGAUX Conformit la Federal Communications Commission (FCC) Cet quipement a t test et dclar conforme aux limites dun appareil numrique de classeB, en vertu de la partie15 du rglement de la FCC. Ces limites sont prvues pour fournir une protection raisonnable contre les interfrences nuisibles avec une installation rsidentielle ou lorsque lquipement est utilis dans un environnement commercial. Cet quipement gnre, utilise et peut mettre des frquences radio et, sil nest pas install et utilis conformment aux instructions, causer des interfrences nuisibles aux communications radio. Cependant, il nexiste aucune garantie que des interfrences ne se produiront pas dans une installation particulire. Si cet quipement provoque des interfrences nuisibles la rception dune diffusion sonore ou visuelle, ce qui peut tre dtermin en lallumant et en lteignant, lutilisateur est invit essayer de rsoudre ce problme en prenant une ou plusieurs des mesures suivantes: Augmenter la distance entre lquipement et le rcepteur. Connecter lquipement un circuit autre que celui auquel le rcepteur est connect. Consulter le concessionnaire pour obtenir de laide.Canada - Conformit Underwriters Laboratories (C-UL)Pour les applications homologues C-UL, lunit doit tre installe conformment la partie1 du Code canadien de llectricit.Dni de responsabilit et restrictions concernant la documentationLinformation contenue dans ce document peut tre modifi e sans pravis et ne constitue pas un engagement de la part de LiftMaster. Pour obtenir linformation la plus jour, visiter www.LiftMaster.com. Ce document et les donnes fournies aux prsentes ne doivent pas tre copis, utiliss ou divulgus dautres personnes des fi ns dapprovisionnement ou de fabrication, sauf en cas de permission crite de la part de LiftMaster. Linformation contenue dans ce document ou au sein du produit lui-mme est considre comme la proprit exclusive de LiftMaster. Toute information dans ce document ou au sein du matriel et des produits logiciels eux-mmes est protge par droit dauteur et/ou dautres lois des tats-Unis sur la proprit intellectuelle.Unit de contrle daccs UL 294 de niveau 1 (Attaque, Endurance, Scurit de ligne, Veille)
AVIS: Les rgles de la FCC et/ou dIndustrie Canada (IC) interdisent tout ajustement ou toute modifi cation de ce rcepteur. IL NEXISTE AUCUNE AUTRE PICE SUSCEPTIBLE DTRE ENTRETENUE PAR LUTILISATEUR. Tout changement ou modifi cation non expressment approuv par la partie responsable de la conformit pourrait annuler lautorit de lutilisateur dutiliser lquipement. Ce dispositif est conforme la partie15 des rgles de la FCC et des normes RSS exemptes de licence dIndustrie Canada (IC). Lutilisation est sujette aux deux conditions ci-aprs : (1) ce dispositif ne peut causer des interfrences nuisibles, et (2) ce dispositif doit accepter toute interfrence reue, y compris une interfrence pouvant causer un fonctionnement non dsir.Cet appareil numrique de classe B est conforme la norme ICES-003 du Canada.Ce dispositif a t mis lessai et dclar conforme aux limites tablies pour les dispositifs numriques de classeB, conformment larticle15 des rgles de la FCC. Cette conformit a pour but de fournir une protection raisonnable contre les interfrences nuisibles dans une installation rsidentielle. Cet quipement gnre, utilise et peut mettre des frquences radio et, sil nest pas install et utilis conformment aux instructions, peut causer des interfrences nuisibles aux communications radio. Cependant, il nexiste aucune garantie que des interfrences ne se produiront pas dans une installation particulire. Si cet quipement provoque des interfrences nuisibles la rception dune diffusion sonore ou visuelle, ce qui peut tre dtermin en lallumant et en lteignant, lutilisateur est invit essayer de rsoudre ce problme en prenant une ou plusieurs des mesures suivantes:- Rorienter ou dplacer lantenne de rception.- Augmenter la distance entre lquipement et le rcepteur.- Brancher lappareil une prise sur un circuit diffrent de celui du rcepteur.- Pour obtenir de laide, consulter le dtaillant ou un radiotechnicien chevronn.- Cet appareil doit tre install de manire laisser une distance dau moins 20 cm (8po) entre celui-ci et lutilisateur ou toute personne.
GarantieLiftMaster (le vendeur) garantit lacheteur initial de ce produit pour la structure dans laquelle ce produit est originalement install que le produit est exempt de tout dfaut matriel ou de fabrication pour une priode de deux (2)ans compter de la date dachat.Pour que ce produit fonctionne correctement, il faut se conformer aux instructions relatives linstallation, au fonctionnement, lentretien et la mise lessai. Tout dfaut de se conformer strictement ces instructions annulera la prsente garantie limite dans son intgralit.Si, au cours de la priode de garantie limite, ce produit semble prsenter un dfaut couvert par la prsente garantie limite, appeler au 1800528-2806, avant de dmonter le produit. Envoyer ensuite le produit, en port pay et assur, notre centre de service pour que la rparation soit couverte par la garantie. Les produits retourns au vendeur pour une rparation couverte par la garantie, qui aprs rception par le vendeur seront confi rms comme tant dfectueux et couverts par la prsente garantie limite, seront remplacs ( la discrtion du vendeur) sans frais et retourns port pay. Les pices dfectueuses seront rpares ou remplaces par des pices neuves ou remises neuf en usine, la seule discrtion du vendeur.LA PRSENTE GARANTIE LIMITE REMPLACE TOUTE AUTRE GARANTIE, EXPRESSE OU IMPLICITE, NOTAMMENT TOUTE GARANTIE IMPLICITE DE QUALIT MARCHANDE OU DADAPTATION UN BUT PARTICULIER, OU AUTRE, ET TOUTE AUTRE OBLIGATION OU RESPONSABILIT DE LA PART DU VENDEUR. LA PRSENTE GARANTIE LIMITE NE COUVRE PAS LES DOMMAGES QUI NE SONT PAS DUS UN DFAUT, CEUX CAUSS PAR UNE MAUVAISE INSTALLATION, UNE UTILISATION OU UN ENTRETIEN INADQUAT (INCLUANT, NOTAMMENT, LES AVARIES DUES UN MAUVAIS TRAITEMENT, UN USAGE NON APPROPRI, LABSENCE DENTRETIEN RAISONNABLE ET NCESSAIRE, DES RPARATIONS NON AUTORISES OU TOUTE MODIFICATION CE PRODUIT), LES FRAIS DE MAIN-DUVRE POUR LA RINSTALLATION DUNE UNIT RPARE OU REMPLACE, OU LE REMPLACEMENT DES BATTERIES.LE VENDEUR NE SERA EN AUCUN CAS TENU RESPONSABLE DES DOMMAGES-INTRTS PARTICULIERS OU INDIRECTS RSULTANT DE LUTILISATION OU DE LINAPTITUDE UTILISER CE PRODUIT CORRECTEMENT. EN AUCUN CAS, LA RESPONSABILIT DU VENDEUR POUR BRIS DE GARANTIE, RUPTURE DE CONTRAT, NGLIGENCE OU RESPONSABILIT STRICTE NEXCDERA LE COT DU PRODUIT COUVERT AUX PRSENTES. NUL NEST AUTORIS ASSUMER POUR NOUS DAUTRES RESPONSABILITS RELATIVEMENT LA VENTE DE CE PRODUIT.Certains tats ou provinces nacceptant pas lexclusion ou les restrictions relatives aux dommages-intrts particuliers ou indirects, les restrictions ou exclusions fi gurant dans la prsente garantie pourraient ne pas sappliquer vous. La prsente garantie limite confre certains droits lgaux particuliers lacheteur et il se peut quil ait dautres droits qui varient dune province ou dun tat lautre.
Toutes les marques de commerce, marques de service et noms de produit ou de service sont des marques de commerce ou des marques dposes appartenant leurs titulaires respectifs.
2017 LiftMaster Tous droits rservs.114A4982
-
Controlador de 2 puertas del Portal de acceso
conectado LiftMaster Cloud TM
MANUAL DE INSTALACIN
Mod
elo
CA
P2D
-
2
PREINSTALACIN REDCABLEADO CONTROL DE ACCESOINTRODUCCIN INSTALACIN
INTRODUCCINSeguridad ...................................................................... 3Descripcin general del controlador .............................. 4Descripcin general de la tarjeta de control .................. 4Inventario de la caja ...................................................... 5Herramientas necesarias ............................................... 5Dimensiones ................................................................. 5Especifi caciones ............................................................ 6Clasifi cacin elctrica .................................................... 6Especifi caciones del cable ............................................. 7
PREINSTALACINServicio de Internet ....................................................... 8# de panel de control para el controlador ...................... 8Confi gurar una Cuenta Cloud de LiftMaster................... 8Montaje de la mnsula .................................................. 9
CABLEADOConectar la alimentacin ............................................. 10
RED
Conectar a Internet ...................................................... 11
CONTROL DE ACCESOModo Administrador ................................................... 12Cableado de REX y puertas ......................................... 12Operacin .................................................................... 14Acceso de portn ........................................................ 15Acceso de puerta ......................................................... 16
Hoja de confi guracin ................................................ 18Exencin de responsabilidad ..................................... 19Garanta ...................................................................... 19
1
2
3
4
INSTALACIN5Instalacin del CAP2D ................................................. 17Resolucin de problemas ............................................ 17
Para la programacin de LiftMaster Cloud visite www.LiftMasterCloud.com.
-
3
Para reducir el riesgo de LESIONES GRAVES o la MUERTE: Desconecte la electricidad en la caja de fusibles ANTES de
continuar. Para EVITAR daos en las tuberas de gas, electricidad u otras
tuberas de servicios pblicos subterrneas, comunquese con una empresa dedicada a la localizacin de servicios subterrneos ANTES de iniciar la excavacin.
Todas las conexiones elctricas DEBEN ser hechas por una persona calificada.
TODO el cableado de alimentacin y de control se DEBE instalar en conductos separados.
Para proteger contra incendios y electrocucin: Desconecte la alimentacin ANTES de instalar o realizar el
mantenimiento del controlador. NUNCA conecte un teclado, lector o cerrojo a las puertas sin
consultar antes el cdigo de incendios que se aplica. Primero DEBE consultar a las autoridades locales de incendios y
obtener su aprobacin ANTES de instalar cerrojos o dispositivos en CUALQUIER puerta que pueda ser una salida de incendios.
Es posible que el uso de botones de salida no sea legal. Tal vez sea necesario instalar salidas de accin nica.
SIEMPRE debe obtener los permisos y aprobaciones adecuados por escrito ANTES de instalar el equipo.
SeguridadRevisin de los smbolos y trminos de seguridad. Estas advertencias y smbolos de seguridad que aparecen a lo largo de este manual le alertarn de la existencia de riesgo de una lesin seria o de muerte si no se siguen las instrucciones correspondientes. El peligro puede ser elctrico (electrocucin) o mecnico. Lea atentamente las advertencias.Cuando vea esta palabra clave en las pginas siguientes, se le alertar sobre la posibilidad de que la propiedad o el producto sufran daos si no se siguen las precauciones correspondientes. Lalas detenidamente.
MECNICA
ELECTRICIDAD
PREINSTALACIN REDCABLEADO CONTROL DE ACCESOINTRODUCCIN INSTALACIN
CONFORMIDAD CON LAS NORMAS DE UNDERWRITERS LABORATORIES (UL)El CAP2D cumple el Estndar UL294 para las unidades de control de acceso con las siguientes restricciones: Los contactos del rel del sistema no se deben confi gurar
en el modo a prueba de fallos a menos que la autoridad local que tenga jurisdiccin lo permita y no interfi era con el funcionamiento de la barra antipnico.
El puerto Ethernet es para uso complementario nicamente, la unidad seguir operando de manera autnoma si la conexin a la red se interrumpe.
Esta unidad puede recibir alimentacin mediante un hardware con alimentacin a travs de Ethernet. Si se usa una fuente de alimentacin PoE, esta deber cumplir el estndar UL294.
Todos los dispositivos de interconexin deben tener certifi cacin UL.
NO INSTALE EL SISTEMA EN MODO A PRUEBA DE FALLOS A MENOS QUE EST PERMITIDO POR LA AUTORIDAD LOCAL QUE TENGA JURISDICCIN. El hacerlo puede causar interferencia con el funcionamiento de la barra antipnico.
ADVERTENCIA: Este producto puede exponerlo a sustancias qumicas, incluido el plomo, que a consideracin del Estado de California causan cncer, defectos congnitos u otros daos reproductivos. Para obtener ms informacin, visite www.P65Warnings.ca.gov
-
4
PREINSTALACIN REDCABLEADO CONTROL DE ACCESOINTRODUCCIN INSTALACIN
STATUS
ACTIVE NETWORK
Descripcin general del controlador
Descripcin general de la tarjeta de control
LED DE LA RED LED naranja: Enlace de 100MBit LED azul: Actividad de la redLED derecho azul: Buena conexin a la red
LED ACTIVOAPAGADO/slido: El sistema se est iniciando
Parpadeo: El sistema est operativo.LED DE ESTADOSlido: El sistema tiene alimentacin
Conexin de la tarjeta de control Descripcin
USB administrativo Connectar mediante Mini-USB para acceder al administrativo
LAN/PoE Connectar a la red. Tambin puede conducir alimentacin 802.3af/at
Reserva de batera de Litio La batera preserva los datos del sistema durante los cortes de energa primarios
Heartbeat local El LED indica una funcin adecuada
Indicador de rel Luces LED cuando el rel est activado (una por rel)
Confi guracin de energa El puente selecciona Poe o alimentacin auxiliar
VISTA FRONTAL
LAN
AD
MIN
DRY
RLY1
WET
PSE1
PoE
DRY
WET
RLY2
HRT
BT
REA
DER
1IO
1
REX
COM
DO
OR
RED
GRN
12V
BU
Z
GN
D
D1
D
0
IO
2
REX
COM
DO
OR
REA
DER
2
RED
GRN
12V
BU
Z
GN
D
D1
D
0
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
-12I
N+
USB ADMINISTRATIVO
PUER
TA 1
PUER
TA 2
Rel auxiliar 1
ESTADO DE PEDIDO DE SALIDA
ENTRADA WIEGAND
ESTADO DE PEDIDO DE SALIDA
ENTRADA WIEGAND
PUENTE DE CONFIG. DE POTENCIA
ALIMENTACIN EXTERNA DE 12 V
RESEVA DE PILA BOTN DE LI