CANOVATE MARINE IT SOLUTIONS
Transcript of CANOVATE MARINE IT SOLUTIONS
1
In today’s marine industry, both clients and crew have high expectations when it comes to IT and communications systems on-board. Customers need a fully integrated and automated solution that will provide all daily requirements of cargo and cruise ship. Canovate provides the best rack systems and complete integrated micro DC solutions to house the best system for your navigation, IT and communication needs.
CANOVATE MARINE IT SOLUTIONS
www.canovate.com 2
Index
• Fiber Connectivity ................................................................. 15-16
• Copper Conenctivity ............................................................ 13-14
• PDU ................................................................................................ 12
• Accessories ............................................................................... 9-11
• Micro DC .................................................................................... 6-8
• Wallmount Rack .................................................................... 5
• IT Marine Rack ........................................................................ 3-4
CCE 7/7-16A
www.canovate.com 3
Overview of Marine IT Rack Cabinet
A cost effective rack cabinet system which is developed for marine IT applications. This rack system is designed and engineered for demanding marine and overseas environments with harsh environmental conditions such as vibration and high level of humidity. It is suitable for all servers manufactured by major brands including HP, Dell, Sun, Cisco, Juniper, IBM, Compaq etc.; also all telecommunication and navigation devices required for safe cruising. To achieve optimum versatility within the rack cabinet, users can set multiple depths throughout the cabinet by adjustable 19” mounting rails mounted on heavy duty side supports. Removable side panels provide ease of access and convenient post-installation maintenance. Optional perforations on front and rear doors enable optimum airflow within the rack cabinet.
Technical FeaturesMaterial 1,5 and 2mm Steel
Color RAL 7035 or RAL 9005
Compliance RoHS, UL Certified
Packaging Assembled
Maximum Static Load Up to 300 kg. (in 800x1000 mm)
FinishFrame, doors, side panels, top and bottom covers. Electrostatic Powder Paint,19” mounting rails: Zinc-plated
Standard Configuration • Glass or Perforated front door and solid back panel • Front door with swing handle lock • Solid Side Panels with cylindrical locks and latches • Internal top sheet with 3 cable entries for 800 width,
1 cable entry for 600 width racks and fan cut-outs • 2 Pairs of depth adjustable heavy duty 19” Mounting Rails • 2 Pairs of Adjustable Feet • Bottom cover with 3 cable entries for 800 width,
1 cable entry for 600 width racks
Glass Door Option
Vibration Absorbent Base
Front View Open Side View
IT Marine Rack
www.canovate.com 4
Order Information
HeightU
Outer Width
(W) mm
Outer Depth (D)
mm
Outer Height (H)
mm
Inner Width (w1) mm
Inner Depth (d1) mm
Inner Height (h1) mm
19” Rails Adjust-able Depth Range
(c)Front Door Part No
12U 600 800 624 503 750 464 123 - 573 Glass CSN-M-X-1268A
16U 600 800 832 503 750 672 123 - 573 Glass CSN-M-X-1668A
22U 600 800 1144 503 750 984 123 - 573 Glass CSN-M-X-2268A
12U 600 1000 624 503 950 464 123 - 773 Glass CSN-M-X-1260A
16U 600 1000 832 503 950 672 123 - 773 Glass CSN-M-X-1660A
22U 600 1000 1144 503 950 984 123 - 773 Glass CSN-M-X-2260A
12U 800 1000 624 703 950 464 123 - 773 Glass CSN-M-X-1280A
16U 800 1000 832 703 950 672 123 - 773 Glass CSN-M-X-1680A
22U 800 1000 1144 703 950 984 123 - 773 Glass CSN-M-X-2280A
12U 600 1000 624 503 950 464 123 - 773 Perforated CSS-M-X-1260A
16U 600 1000 832 503 950 672 123 - 773 Perforated CSS-M-X-1660A
22U 600 1000 1144 503 950 984 123 - 773 Perforated CSS-M-X-2260A
12U 800 1000 624 703 950 464 123 - 773 Perforated CSS-M-X-1280A
16U 800 1000 832 703 950 672 123 - 773 Perforated CSS-M-X-1680A
22U 800 1000 1144 703 950 984 123 - 773 Perforated CSS-M-X-2280A
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Technical DrawingRear Panel
Top Sheet
Side Panel
Bottom SheetFront Door
Side Panel
Shock AbsorberFloor Mounting Plate
w1
h1
D
LL
SECTION L-LSCALE 1 : 15
H
W
d1c
REVISIONSZONE REV. DESCRIPTION DATE APPROVED
A İLK ÜRETİM 11/07/2018
DRAWN
CHK'D
MFG
Q.A
FINISH:KESKİN KENAR VE ÇAPAK OLMAYACAKTIR
NAME SIGNATURE DATE
TITLE:
DWG NO.
SCALE:1:50 SHEET 1 OF 1
A3 mm
WEIGHT: Kg
NADİR DOST
16U 600x1000 MARINE IT CAINET ( PERFORATED DOOR )
The
cont
ents
of t
his
dovu
men
t are
pro
perty
of C
ANO
VATE
and
soul
d no
t be
copi
ed, r
epro
duce
d or
dis
clos
ed to
a th
irdpa
rty w
ithou
t writ
ten
cons
ent o
f the
pro
prie
tor
Alem
dağ
Cad
. No:
169
8125
7 Ü
mra
niye
-İSTA
NBU
Lw
ww
.can
ovat
e.co
m
ELEK
TRO
NİK
EN
DÜ
STR
İ TİC
AR
ET A
.Ş.
Bu d
öküm
anın
içer
iği C
ANO
VATE
'in m
ülki
yetin
de o
lup,
yazı
lı iz
in a
lınm
adan
kop
ya e
dile
mez
, ayn
ı biç
imde
oluş
turu
lam
az v
e üç
üncü
şah
ısla
ra a
çıkl
anam
az.
11 Temmuz 2018 Çarşamba 11:34:38
D:\pdmview\canovate\aktarma\n_dost\270-MARINE IT KABINI\27 Haziran 2014 Cuma 17:12:11 11 Temmuz 2018 Çarşamba 13:18:27M18-101
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSurface finish: µ Linear : DIN 7168-mAngular : DIN 7168-mHole : DIN 7168-m
Surface Area : m²
D:\pdmview\canovate\aktarma\n_dost\270-MARINE IT KABINI\
±1.2±0.8>315-1000 >1000-2000
±0.5±0.2>30-120±0.3
>0-6±0.1TOL.
OLCU >6-30 >120-315DIN 7168-m
GENEL TOLERANSLAR
M18-101MATERIAL: Thickness11.07.2018
IT Marine Rack Rear PanelTop Sheet
Side Panel
Bottom SheetFront Door
Side Panel
Shock AbsorberFloor Mounting Plate
w1
h1
D
LL
SECTION L-LSCALE 1 : 15
H
W
d1c
REVISIONSZONE REV. DESCRIPTION DATE APPROVED
A İLK ÜRETİM 11/07/2018
DRAWN
CHK'D
MFG
Q.A
FINISH:KESKİN KENAR VE ÇAPAK OLMAYACAKTIR
NAME SIGNATURE DATE
TITLE:
DWG NO.
SCALE:1:50 SHEET 1 OF 1
A3 mm
WEIGHT: Kg
NADİR DOST
16U 600x1000 MARINE IT CAINET ( PERFORATED DOOR )
The
cont
ents
of t
his
dovu
men
t are
pro
perty
of C
ANO
VATE
and
soul
d no
t be
copi
ed, r
epro
duce
d or
dis
clos
ed to
a th
irdpa
rty w
ithou
t writ
ten
cons
ent o
f the
pro
prie
tor
Alem
dağ
Cad
. No:
169
8125
7 Ü
mra
niye
-İSTA
NBU
Lw
ww
.can
ovat
e.co
m
ELEK
TRO
NİK
EN
DÜ
STR
İ TİC
AR
ET A
.Ş.
Bu d
öküm
anın
içer
iği C
ANO
VATE
'in m
ülki
yetin
de o
lup,
yazı
lı iz
in a
lınm
adan
kop
ya e
dile
mez
, ayn
ı biç
imde
oluş
turu
lam
az v
e üç
üncü
şah
ısla
ra a
çıkl
anam
az.
11 Temmuz 2018 Çarşamba 11:34:38
D:\pdmview\canovate\aktarma\n_dost\270-MARINE IT KABINI\27 Haziran 2014 Cuma 17:12:11 11 Temmuz 2018 Çarşamba 13:18:27M18-101
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSurface finish: µ Linear : DIN 7168-mAngular : DIN 7168-mHole : DIN 7168-m
Surface Area : m²
D:\pdmview\canovate\aktarma\n_dost\270-MARINE IT KABINI\
±1.2±0.8>315-1000 >1000-2000
±0.5±0.2>30-120±0.3
>0-6±0.1TOL.
OLCU >6-30 >120-315DIN 7168-m
GENEL TOLERANSLAR
M18-101MATERIAL: Thickness11.07.2018
www.canovate.com 5
Wallmount Rack
Order Information
HeightU
Outer Width
(W) mm
Outer Depth (D)
mm
Outer Height (H)
mm
Inner Width (w1) mm
Inner Depth (d1) mm
Inner Height (h1)
mm
19” Rails Adjustable Depth Range (c)
Weightkg Part No
6 600 400 366 510 360 266 110-305 15 WS3O-X-0664A
6 600 560 366 510 520 266 110-465 18 WS3O-X-0665A
9 600 400 488 510 360 408 110-305 19 WS3O-X-0964A
9 600 560 488 510 520 408 110-465 22 WS3O-X-0965A
12 600 400 621 510 360 541 110-305 23 WS3O-X-1264A
12 600 560 621 510 520 541 110-465 26 WS3O-X-1265A
15 600 400 755 510 360 674 110-305 27 WS3O-X-1564A
15 600 560 755 510 520 674 110-465 30 WS3O-X-1565A
18 600 400 888 510 360 808 110-305 21 WS3O-X-1864A
18 600 560 888 510 520 808 110-465 34 WS3O-X-1865A
21 600 400 1022 510 360 942 110-305 33 WS3O-X-2164A
21 600 560 1022 510 520 942 110-465 38 WS3O-X-2165A
X (Color code): 7:RAL 7035 Light Grey, 9:RAL 9005 Black
Single Wallmount Cabinet with Openable Side Panels From OutsideTechnical Features
Material 1-1,5-2 mm steel
Color RAL 7035 or RAL 9005
Maximum Static Load
Up to 80 kg.
Finish Electrostatic Powder Paint
Standard Configuration: • Steel frame • Glass door with cylindrical lock • Openable side panels from outside • 1 Pair of heavy duty 19” Mounting Rails • RoHS compliant, UL Certificated • Flat Pack option available
Option: • Adjustable feet or Castor Set (Solid front door) • Available as floor standing cabinet as an option with
castors or adjustable feet
600
643
,35
560
400
471
,35
8,50
www.canovate.com 6
Overview of Canovate Micro DC SolutionAn emerging trend in data center design is compact Micro Data Center, which provides cost effective, energy efficient data centerservice with a rapid deployment time frame.
Canovate® Micro Data Center solution is the right and cost effective answer for this increasing demand. Canovate® Micro DC solution is an integrated data center solution that incorporates Racks, UPS , Cooling , Fire Suppression, PDU and Environmental Monitoring System (EMS) in a compact single platform. Remote monitoring feature allows the group headquarters to perform unified management for IT, telecommunication, navigation activities and allows multiple vessels to be controlled on a single platform.The Micro Data Center approach not only reduces CAPEX dramatically in comparison with traditionally constructed DC; but also provides to source all the components of a datacenter from a single vendor as an advantage.
Highlights:
• Micro Plug & Play Data Center including cooling, fire suppression, monitoring, power management and protection
• Stand-alone Data Center • Eliminates the requirement for raised floor and external
cooling equipment • Individual rack cooling with from 2 kW up to 4 kW • High level security with in rack fire protection and
monitoring systems • Advanced power management enabled by IP PDU and
UPS systems • Install Data Center where you want and need it • Rapid deployment in 4-6 weeks from plan to start-up • Low total cost of ownership • Up to 50% space savings • EMS (Environmental Monitoring System) • DCIM option • IP PDU • UPS • Fire Detection/Extinguisher System (2U) • Protection Grade:IP54
Order Information
HeightU
Outer Width(W) mm
Outer Depth (D) mm
Outer Height (H)mm
(IncludingCooling unit)
19” RailsAdjustable Depth
Range (c)
Cooling Capacity Part No
24U 600 1000 1651 129-729 2 kW CPJ-X-2460A-T2K
24U 600 1000 1651 129-729 4 kW CPJ-X-2460A-T4K
36U 600 1000 2263 129-729 2 kW CPJ-X-3660A-T2K
36U 600 1000 2263 129-729 4 kW CPJ-X-3660A-T4K
42U 600 1000 2529 129-729 4 kW CPJ-X-4260A-T4K
Outer Heights include cooling unit Height of Cooling Unit: 2 kW : 496 mm, 4 kW : 496 mm
Cooling
Capacity
up to
4 kW
Door Contact
Liquid Sensor
Air Flow Sensor
2U Fire Extinguisher Systemwith
FM200 or Novec1230
Rack MountableUPS
AC Unit
IP PDUEnvironmental
Monitoring System
Temperature
* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Micro DC
www.canovate.com 7
Benefits of Canovate® Micro Data CenterAccelerated Deployment: Deploy turnkey rack-level infrastructure in max 1 hour time.Lower CAPEX: Significantly lower initial investment and construction cost compared to classical Data Centers.Increased Energy Efficiency: Dramatically lower your cooling and power OPEX costsCustomizable: Can be customized easily according to your cooling and power requirements.Significant Energy Savings: You don’t need to cool the entire IT room, just cool the Micro DC. (Green IT)Modular: Additional Micro DC units can be added according to the growth of your IT requirements. Pay-As-You-Grow! Portable: Micro DC can be installed on wheels to be moved to different locations easily.Security: Keeps mission critical data in a secure environment, increases data and hardware protection and guarantees 24/7 business continuity via integrated fire suppression and EMS systemsFacility Maintenance: The ability to minimize IT infrastructure maintenance to lower overall Data Center maintenance labor costs.Limited Operation Risk: The complete system is coming as factory tested and ready to install. Plug and Play.Standardization: Same standard solution in all your branch offices limits risks of human failure and lowers operating & maintenance costs.No need for skilled IT personnel: You don’t need to maintain ITStaff in every location , hundreds of Micro DC can be controlled remotely from the Head Quarters.Affordable by Small Businesses: You don’t need to worry for a complex DC design and installation work.
Server Room Construction Micro Data Center
Initial Costs High Low
Construction Time Long Short
Flexibility Low High
Cooling Efficiency Low High
Scalability Low High
ServerRoom
MicroDC
10.000
20.000
Around30.000 $
Around10.000 $
30.000
40.000
AroundAround
InitialCost Reduction
InitialCost Reduction
%67%67
Micro DC
www.canovate.com 8
Components of Micro Data Center
AC Unit (Air Condition Unit) for Micro Data Center
• 2KW - 4KW • 115~480VAC, 50~60Hz • A special door switch controls the compressor • 20°C / 50°C External temperature range • 20°C / 45°C Internal temperature settings • Minimized maintenance with no filter design • 50Kg(2KW) - 85Kg(4KW) weight
UPS (Uninterruptible Power Supply) • 4U-5U 19” size • 3-6-10 KVA Output Power • High frequency and online double conversion technology • 12V VRLA batteries for backup • Three segment charging mode • Cold start function • LCD display • Optional ethernet module for remote monitoring - management
KVM (Keyboard Video Mouse) • 1U size • 17” or 19” TFT LCD screen • 8/16 ports KVM switch • On screen display • Hot key function • Hot plug function • Daisy chain structure
DCIMOur Software recognizes cameras, probes, monitors, sensors, and access control hardware. It’s instantly compatible with hundreds of third party cameras. Use the quick wizards to configure your preferences and parameters. Set your group policies for Administrators and Limited users and specify access control privileges for physical and logical resources via the Access Control section.
Intelligent Access Control System • Embedded Numeric Keypad • Embedded RFID card reader • Finger print reader • Electronic swing handle with additional key for emergency • Ethernet module for management - remote monitoring - user assignment
Environmental Monitoring System • Smoke • Vibration • Motion • Door Contact • Water • Dry Contact • Gas and Chemical • Air Pressure • Air Flow • Air Quality • Combo Temperature & Humidity • Light Detection
Fire Suppression • 2U 19” size • FM200 - Novec1230 extinguishing gas • Battery for up to 24H standby time fully functional • Optional Ethernet module for remote monitoring • 1.5 m³ (Including single tube) or 3.0 m³ (Including double tubes) versions
available
Micro DC
www.canovate.com 9
Material 1.5 mm Steel Maximum Static Load 15-25 kg
Finish Electrostatic Powder Paint Packaging Bubble Nylon
H (U) D (mm)
W (mm)
Inner W
(mm)
Weight kg Part No
1U 150 483 437 0,84 CCA-X-1001
2U 250 483 437 1,58 CCA-X-1002
2U 400 483 437 2,43 CCA-X-1003
19” Cantilever Shelf
Vibration Absorbent Base
H
W
Inner W
D
* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
Material 1.0 mm Steel Maximum Static Load 50 kg
Finish Electrostatic Powder Paint
Packaging One piece in a box
H (U) D (mm) W (mm) Weight kg Part No
1U 345 465 1,22 CCA-X-1004
1U 525 465 1,83 CCA-X-1005
1U 700 465 2,44 CCA-X-1006
1U 900 465 3,05 CCA-X-1007
19” Fixed Shelf
W
D
H
Material 2 mm Steel, Rubber&Metal Alloy
Finish Electrostatic Powder Paint
Packaging two pieces in a box
H (mm) D (mm) W (mm) Weight kg Part No
30 150 594* 2,40 CCA-X-9050
30 150 794** 2,70 CCA-X-9051
* For 600 mm width racks** For 800 mm width racks
Accessories
www.canovate.com 10
Fan Module for Inorax-ST seriesOperating Voltage AC 220 / 240 Volts 50/60 Hz
Standards Conforms to IEC 297-1 Air Flow 85 / 97 CFM
Noise 42,2 / 44,5 dB (A) Material 1,5 mm Steel
Fan Speed 2600 / 2900 rpm Finish Electrostatic Powder Paint
Packaging One piece in a box
H (mm)
D (mm)
W (mm)
Number of Fans
Weight kg Part No
47 375 363 2 2,90 CSA-X-2001
47 375 363 4 3,95 CSA-X-2002
* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
19” Drawer
D
H
WINNER W
Material 1.5 mm Steel Maximum Static Load 35 kg
Finish Electrostatic Powder Paint
Packaging One piece in a box
H (U) D (mm)
W (mm)
Inner W
(mm)
Weight kg Part No
2U 500 483 435 6,36 CCA-X-1016
3U 500 483 435 9,54 CCA-X-1017
Accessories
Fan Module for Wall Mount Enclosures
Operating Voltage AC 220 / 240 Volts 50/60 Hz
Standards Conforms to IEC 297-1 Air Flow 85 / 97 CFM
Noise 42,2 / 44,5 dB (A) Material 1,5 mm Steel
Fan Speed 2600 / 2900 rpm
Finish Electrostatic Powder Paint
Packaging One piece in a box
H (mm)
D (mm)
W (mm)
Number of Fans
Weight kg Part No
39 135 326 1 1,27 CWA-X-2001
39 135 326 2 1,80 CWA-X-2002
www.canovate.com 11
19” 1U Horizontal Cable Organizer with Plastic Hooks
Material 1,5 mm Steel Finish Electrostatic Powder PaintPackaging One piece in a box
H (mm) D (mm) W (mm) Weight kg Part No
1U 80 483 0,49 CCA-X-5001
* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)
19” Cable Entry with Brush
Material 1,5 mm Steel, Brush Finish Electrostatic Powder PaintPackaging One piece in a box
H (U) D (mm) W (mm) Weight kg Part No
1U 10 483 0,2 CCA-X-5031
2U 10 483 0,3 CCA-X-5032
W
H
D
Earthing Kit
Earthing Bar
Material CopperFinish PVC JacketPackaging One set in a box
Length (mm) Cross Section Weight kg Part No
300 2,5 0,08 CCA-0-7017
Material CopperPackaging One set in a box
Length (mm) Cross Section (mm) Weight gr Part No
490 3x15 278 CCA-0-7019
140 3x15 76 CCA-0-7021
Accessories
www.canovate.com 12
Basic PDUBasic PDU (power distribution unit) is a device for providing electrical power in a data center or where any power connectivity needed. It is designed to provide standard electrical outlets for data center equipment.Canovate homemade produced Basic PDUs will lower purchasing costs.
Features • 1U-1.5U Horizontal and 0U Vertical enclosure with C13,C19, Schuko, UK, French, Universal Type and etc. availability.• 115V AC-230V AC, 50/60 Hz, 13-16 Amp or 32-Amp power inlet and single or 3 phase option• Circuit breaker, surge protector or on-off switch availability.• Design and production for all varieties of plug and socket types
IEC C13 TYPE
SCHUKO TYPE
HorizontalProduct Code Product DescriptionPB-C06-100-116 1,5U 19” Aluminium 6 way with on/off switch (*)PB-C06-010-116 1,5U 19” Aluminium 6 way with circuit breakerPB-C08-100-116 1,5U 19” Aluminium 8 way with on/off switch (*)
Horizontal
Product Code Product Description
PB-S04-100-116 1,5 U 19” Aluminium 4 way with on/off switch (*)
PB-S04-010-116 1,5 U 19” Aluminium 4 way with circuit breaker
PB-S06-100-116-W 1U 19” Aluminium 6 way with on/off switch (*)
PB-S06-010-116-W 1U 19” Aluminium 6 way with circuit breaker
PB-S08-100-116-W 1U 19” Aluminium 8 way with on/off switch (*)
19” Horizontal IP-PDUCanovate offers reliable, high quality data center power distribution units (PDUs) designed for maximum performance. Canovate’s power distribution units are available from robust basic units to sophisticated intelligent PDUs.
• Remote monitoring and management via network• Remote power monitoring of voltage (Volts), current
(Amps), power (kW,kVA) and energy consumption (kWh) entire PDU level
• Outlet based switching capability• Embedded Web Interface with graphics• Embedded Environmental Monitoring Capability• 1XCombo Temperature & Humidity sensor• 1x Dry contact input for any sensor connectivity up to
4 sensors (water, fan, door switch, etc.)• Management over SNMP v2
• 100Mbit Ethernet• SMTP (Email notification of alarms)• SNTP (Time Protocol)• Authorized Access feature• Total 25 Amper on / off 250VAC / 10A per socket• High frequency filter• Timer Function• Software upgrade via USB
Features
Horizontal
Product Code Product Description
PC-C07-400-X16-203F Horizontal, total based measurable and socket based managed IP PDU, 1 phase, 7C13 socket, 3x2.5 mm2 3m cable,16A
PDU
CCE 7/7-16A
Combo Temperature& Humidity Sensor
Ethernet Input
Dry Contact Input
CCE 7/7-16A
www.canovate.com 13
Copper Cables
Category 6A MR/UTP 500MHz LAN Cables
Canovate® category 6A cable series consists of 100 Ohm impedance, 4-pair MR/UTP (Metal Reflector) cables for horizontal installations in local area networks (LANs). All cables fully conform to all Category 6A requirements of TIA/EIA-568-C.2 and Category 6A IEC 61156-5( Second Version)
Category 6 U/UTP 250MHz LAN Cables
Canovate® category 6 cable series consists of 100 Ohm impedance, 4-pair U/UTP cables for horizontal installations in local area networks (LANs). All cables fully conform to and provide a substantial margin above all Category 6 requirements of TIA/EIA-568-C.2 and IEC 61156-5( Second Version)
Copper Patch Cords
Category 6A UTP Patch Cords
• 2 x Cat.6A RJ45 plug, LSZH or PVC • 10 Gbit 500MHz • Unshielded • TIA/EIA 568B coded
Category 6 UTP Patch Cords
• 2 x Cat.6 RJ45 plug, LSZH or PVC • Unshielded • TIA/EIA 568B coded
Copper Connectivity
www.canovate.com 14
Copper Patch Panels
24 Port UTP Category 5e Patch Panel 1U
Highlights • 24 Port unshielded RJ45 jacks • Contacts are phosphor bronze plated with 50 micro inches
hard gold • Class D (100MHz) acc. to ISO/IEC 11801 and EN50173 • Printed with color code TIA 568A/B, 8 pole LSA terminals • 19” steel sheet housing
Applications • 100 Base-TX • 100 Base-T • 100VG-Any LAN • 1000 Base-T(Gigabit Ethernet) • 1000 Base-TX
Part No Type
KU0-0-PP1U24-C5e-R45-2 24 Port Cat.5e UTP Patch Panel, 1U, Black
24 Port UTP Category 6 Patch Panel 1UHighlights
• 24 port unshielded RJ45 jacks • Contacts are phosphor bronze plated with 50 micro inches
hard gold • Class E (250MHz) acc. to ISO/IEC 11801 and EN50173 • Printed with color code TIA 568A/B, 8 pole LSA terminals • 19” steel sheet housing
Applications • 100 Base-TX • 100 Base-T • 100VG-Any LAN • 1000 Base-T(Gigabit Ethernet) • 1000 Base-TX
Part No Type
KU0-0-PP1U24-C6-R45-2 24 Port Cat.6 UTP Patch Panel, 1U, Black
Copper Connectivity
www.canovate.com 15
1U/2U 19” Angled Patch Panels with Telescopic Rails CAN-FPP-200
OverviewEnsures professional cable management and limits the risk of health problems due to laser contact to eyes. Side facing fiber position for high laser safety.
Highlights • 1U and 2U versions (12, 24, 36 and 48 port capacity) • Confirms 19” or ETSI • Professional and advanced cable management with 45
degree adaptor interface • Angled adaptor interface protects your eyes from undesired
contact with laser beam coming from the adaptors-Laser safety!
• Quick-stud system ensures easy closing /opening of the front cover
• Easy access with telescopic rail pull-out system • Special protection tubes and bend radien for protecting
the incoming fiber from bending and guiding the fibers to the special designed splice cassettes in a professional way
• Special splice cassettes of 12 or 24 port capacity with professional cable storage and protection
• 100% Compatible to Bellcore GR-326 standards • Confirms to every type of connectors
(ST, SC, FC, LC, MTRJ, E2000, etc.)
Technical DetailsDimensions 1U: 465 mm (W) x 238 mm (D) x 44,45 mm
(H)2U: 465 mm (W) x 238 mm (D) x 88,15 mm (H)
Material Mild Steel
Color Powder coat RAL7035 or RAL9005
Weight 6 kg (2U), 4 kg (1U)
ApplicationsFTTX applications, Datacenter and LAN & WAN projects.
1U Version
2U Version
Telescopic Rail SystemSecured cable entry
Fiber Connectivity
www.canovate.com 16
Part No Type
KSM-x-PCSxyyy-0-SCzzuu-t yyy meter SC-zz/uu Simplex SM Fiber Patch Cord, x, t
KSM-x-PCDxyyy-0-SCzzuu-t yyy meter SC-zz/uu Duplex SM Fiber Patch Cord, x, t
KMM-x-PCSxyyy-0-SCzzuu-t yyy meter SC-zz/uu Simplex MM Fiber Patch Cord, x, t
KMM-x-PCDxyyy-0-SCzzuu-t yyy meter SC-zz/uu Simplex MM Fiber Patch Cord, x, t
Part No Type
KSM-x-PCSxyyy-0-LCzzuu-t yyy meter LC-zz/uu Simplex SM Fiber Patch cord, x, t
KSM-x-PCDxyyy-0-LCzzuu-t yyy meter LC-zz/uu Duplex SM Fiber Patch cord, x, t
KMM-x-PCSxyyy-0-LCzzuu-t yyy meter LC-zz/uu Simplex MM Fiber Patch cord, x, t
KMM-x-PCDxyyy-0-LCzzuu-t yyy meter LC-zz/uu Duplex MM Fiber Patch cord, x, t
Part No Type
KSM-x-PCSXyyy-0-FCzzuu-t yyy meter FC-zz/uu Simplex SM Fiber Patch cord, x, t
KSM-x-PCDXyyy-0-FCzzuu-t yyy meter FC-zz/uu Duplex SM Fiber Patch cord, x, t
KMM-x-PCSXyyy-0-FCzzuu-t yyy meter FC-zz/uu Simplex MM Fiber Patch cord, x, t
KMM-x-PCDXyyy-0-FCzzuu-t yyy meter FC-zz/uu Duplex MM Fiber Patch cord, x, t
Part No Type
KSM-x-PCSXyyy-0-FCzzuu-t yyy meter FC-zz/uu Simplex SM Fiber Patch cord, x, t
KSM-x-PCDXyyy-0-FCzzuu-t yyy meter FC-zz/uu Duplex SM Fiber Patch cord, x, t
KMM-x-PCSXyyy-0-FCzzuu-t yyy meter FC-zz/uu Simplex MM Fiber Patch cord, x, t
KMM-x-PCDXyyy-0-FCzzuu-t yyy meter FC-zz/uu Duplex MM Fiber Patch cord, x, t
Part No Type
KSM-x-PCSXyyy-0-STzzuu-t yyy meter ST-zz/uu Simplex SM Fiber Patch cord, x, t
KSM-x-PCDXyyy-0-STzzuu-t yyy meter ST-zz/uu Duplex SM Fiber Patch cord, x, t
KMM-x-PCSXyyy-0-STzzuu-t yyy meter ST-zz/uu Simplex MM Fiber Patch cord, x, t
KMM-x-PCDXyyy-0-STzzuu-t yyy meter ST-zz/uu Duplex MM Fiber Patch cord, x, t
E2000 Patch Cords
FC Patch Cords
x : “L” LSZH / “P” PEyyy : Available lengths in meter 0.5/1/1.5/2,3,5 and 10 (up to 70m special)zz: SC:SC / LC:LC / ST:ST / MJ: MT-RJ / FC: FCuu: “AP” APC / “UP” UPC t: Available colors (0: White, 1:Grey 2:Black, 3:Red, 4:Green, 5:Blue, 6:Yellow, 7:Orange)
SC Patch Cords
ST Patch Cords
LC Patch Cords
Canovate® patch cords are outstanding with different buffer and jacket types and colors, including out diameter (2-3 mm), tight buffers or jacketed mini cables in simplex or duplex (zip-cord) constructions.
FIBER PATCH CORDS
How to order
Order Example: KMM-L-PCDX150-0-SCLCUP-7: Multi Mode 1.5m SC/LC UPC Duplex Patch Cord, LSZH, Orange, 2mm
K-- PC----- ------0 --
SM:Single Mode / MM: Multi ModeL: LSZH / F: PVC
SX150: Simplex 1,5m /DX050: Duplex 0,5mSX100: Simplex 1,0m / DX200: Duplex 2,0m
0: White / 1: Grey / 2: Black / 3: Red 4: Green / 5: Blue/ 6: Yellow /7 Orange SCSCUP: SC/SC UPC/ LCLCAP: LC/LC APC SCLCAP: SC/LC APC / STSCUP: ST/SC/UPC
Fiber Connectivity