450 – 1 Street SW Calgary, Alberta T2P 5H1 Tel: (403) 920-5214 Fax: (403) 920-2347 Email: [email protected] May 13, 2021 Filed Electronically Canada Energy Regulator Suite 210, 517 Tenth Avenue SW Calgary, AB T2R 0A8 Attention: Mr. Jean-Denis Charlebois, Secretary of the Commission Dear Mr. Charlebois: Re: NOVA Gas Transmission Ltd. (NGTL) 2021 NGTL System Expansion Project (Project) Order XG-001-2020 (as amended) (Order) Application for Partial Leave to Open (LTO) Nordegg C6 Compressor Station File: OF-Fac-Gas-N081-2018-0303 Pursuant to section 213 of the Canadian Energy Regulator Act, NGTL applies for partial LTO for the Nordegg C6 Compressor Station Unit Addition (Nordegg CS) portion of the Project following completion of the Nordegg CS hydrotest program. This application includes the following: High pressure gas piping installed to date including recycle valve, unit valves and relief valves Gas vents and hydrocarbon drains Fuel gas piping NGTL anticipates filing the final LTO for the balance of the Nordegg CS prior to the end of June 2021. In it’s Project update filed on August 7, 2020, 1 NGTL requested exemption from the requirements of sections 180(1)(b) and 213(1) of the Canadian Energy Regulator Act (CER Act) to obtain leave to open (LTO) from the CER prior to installing tie-in assemblies, utility gas system and auxiliary systems. NGTL’s request for exemption from LTO for the above-mentioned components was approved by the CER. As committed to in NGTL’s exemption request, NGTL provides a copy of the hydrotest information to the CER (Appendix A). The documents to support this LTO were prepared in accordance with Guide T of the Filing Manual (see Table 1). The supporting documents, contained in Tab A through Tab C, as 1 CER Filing ID: C07711.

Transcript of Canadian Energy Regulator Act - apps.cer-rec.gc.ca

450 – 1 Street SW Calgary, Alberta T2P 5H1

Tel: (403) 920-5214 Fax: (403) 920-2347 Email: [email protected]

May 13, 2021 Filed Electronically

Canada Energy Regulator Suite 210, 517 Tenth Avenue SW Calgary, AB T2R 0A8

Attention: Mr. Jean-Denis Charlebois, Secretary of the Commission

Dear Mr. Charlebois:

Re: NOVA Gas Transmission Ltd. (NGTL) 2021 NGTL System Expansion Project (Project) Order XG-001-2020 (as amended) (Order) Application for Partial Leave to Open (LTO) Nordegg C6 Compressor Station File: OF-Fac-Gas-N081-2018-0303

Pursuant to section 213 of the Canadian Energy Regulator Act, NGTL applies for partial LTO for the Nordegg C6 Compressor Station Unit Addition (Nordegg CS) portion of the Project following completion of the Nordegg CS hydrotest program.

This application includes the following: • High pressure gas piping installed to date including recycle valve, unit valves and relief

valves • Gas vents and hydrocarbon drains • Fuel gas piping

NGTL anticipates filing the final LTO for the balance of the Nordegg CS prior to the end of June 2021.

In it’s Project update filed on August 7, 2020,1 NGTL requested exemption from the requirements of sections 180(1)(b) and 213(1) of the Canadian Energy Regulator Act (CER Act) to obtain leave to open (LTO) from the CER prior to installing tie-in assemblies, utility gas system and auxiliary systems. NGTL’s request for exemption from LTO for the above-mentioned components was approved by the CER. As committed to in NGTL’s exemption request, NGTL provides a copy of the hydrotest information to the CER (Appendix A).

The documents to support this LTO were prepared in accordance with Guide T of the Filing Manual (see Table 1). The supporting documents, contained in Tab A through Tab C, as

1 CER Filing ID: C07711.

May 13, 2021 Mr. Charlebois Page 2 of 2 attached, constitute the materials required by the Canada Energy Regulator (CER) for its review and consideration of NGTL’s LTO Application. NGTL confirms that all pressure tests for this LTO Application were conducted in accordance with Canadian Standards Association Z662-19: Oil and Gas Pipeline Systems (CSA Z662).

Table 1: Supporting Documents for Leave to Open

Tab Contents

A Leave to Open Document: Nordegg C6 Unit Addition

A Guide T Checklist

B Hydrotest Summary Report

B TC Energy Standards, Specifications and Procedures

B Summary of Pipe Manufacturers

B Summary of Piping, Welds and Valves Not Tested Following Installation

B Schematic of Pressure Tested Facility

C TC Energy Pressure Test Report signed by TC Energy representative

C Pressure and Temperature Log Sheets

C Line Lists

C Pressure Recorder Charts

C Piping and Instrumentation Diagram and Isometric Drawings

C Test Equipment Calibration Certificates for the Instruments Used for the Test

NGTL requests the CER’s determination of this LTO Application by June 10, 2021, in order to maintain Project schedule and achieve its in service date. In the event that the installation cannot proceed as planned, the delay may impact current service to existing customers.

If the CER requires additional information with respect to this filing, please contact me by phone at (403) 920-5214 or by email at [email protected].

Yours truly, NOVA Gas Transmission Ltd.

Original signed by

Jaron Dyble Regulatory Project Manager Regulatory Facilities, Canadian Natural Gas Pipelines

Enclosure

cc: Heather Dodds, Canada Energy Regulator

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

TAB A

Leave to Open Document

Guide T Checklist

05/11/2021

05/11/2021

Digitally signed by Andrew WytsmaDN: C=CA, [email protected], O=TransCanada, OU=Compresson Projects, CN=Andrew WytsmaDate: 2021.05.11 09:39:57-06'00'

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (As Amended) Application for Leave to Open Nordegg CS

May 2021 Page 1 of 1

GUIDE T CHECKLIST – FOR A PIPELINE OR PIPELINE SECTION

ITEM REQUIREMENTS WHERE INCLUDED TAB 1.0 NEB certificate or order number under which work was

carried out. Leave to Open Application Letter Cover

2.0 A list of standards, specifications and procedures to and under which the facilities were designed, constructed and tested.

TC Energy Standards, Specifications and Procedures

List

B

3.0 A description of the pressure-tested facilities including:

Hydrotest Summary Report B

3.1 The MOP Leave to Open Document B 3.2 The location Leave to Open Document B 3.3 The piping specifications, including the pipe manufacturer TC Energy Standards,

Specifications, and Procedures Summary of Pipe Manufacturers

B

3.4 A schematic of the pressure-tested facilities Schematic of Pressure Tested Facility

B

3.5 Where applicable, the elevation profile of the test section, including high, low and test point elevations

Not Applicable (N/A) -

4.0 A summary of continuous pressure and temperature readings for the pipeline test section over the test period, including:

Hydrotest Summary Report B

4.1 The date of the test Hydrotest Summary Report B 4.2 The test medium Hydrotest Summary Report B 4.3 The minimum and maximum allowable test pressures Hydrotest Summary Report B 5.0 A summary of all piping, welds, and valves not

subjected to a pressure test following installation (e.g. pre-tested pipe and assemblies) with justification for not pressure testing following installation

Summary of Piping, Welds, and Valves Not Tested Following

Installation

B

6.0 A statement that all control and safety devices were or will be inspected and tested for functionality

Leave to Open Document A

7.0 Confirmation that any permits required for the use and disposal of water was obtained

Leave to Open Document A

8.0 Confirmation that required tests were taken and met requirements

Leave to Open Document A

8.1 Confirmation that all field joints were non-destructively tested

Leave to Open Document A

8.2 Confirmation that the test pressure did not fall below the 97.5% of the minimum strength test pressure

Leave to Open Document A

8.3 Confirmation that pressure testing was performed under the direct supervision of a company representative

Leave to Open Document A

9.0 Test equipment calibration certificates Test Documentation C 10.0 All logs, test charts and other test records, signed and

dated by the company representative Test Documentation C

11.0 Details regarding any unsuccessful pressure tests, including the cause of the test failure

N/A N/A

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

TAB B

Hydrotest Summary Report

TC Energy Standards, Specifications, and Procedures

Summary of Pipe Manufacturers

Summary of Piping, Welds and Valves Not Tested Following Installation

Schematic of Pressure Tested Facility

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 1 of 48

Leave to Open Hydrostatic Test Summary Report

Hydrostatic Test Details Test Number: Test Package No. STRIKEND2-2020S15 Description: High Pressure Gas System Module N-D-03 Spool Control Numbers: D3-011; D3-012; D3-023

Reference Drawings: 0635-01-C6-04-HG-0108-03_01 0635-01-C6-04-HG-0183-03_00

0635-01-C6-04-HG-0158-03_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-48-D1-HG-108-N C6-3-D1-HG-183-N

C6-2-D1-HG-158-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,032 kPa(g) Actual Maximum: 11,095 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: August 15, 2020 – 14:59 to 16:14 hours Test Ambient Temperature: 27.0 to 25.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 2 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA1-2020S18 Description: High Pressure Gas System Module N-A-01 Spool Control Numbers:

A1-001; A1-002; A1-003; A1-004; A1-005; A1-006; A1-007; A1-008; A1-009; A1-010; A1-011; A1-012; A1-110; A1-111

Reference Drawings:

0635-01-C6-04-FG-0710-02_00 0635-01-C6-04-FG-0710-04_00 0635-01-C6-04-FG-0712-01_00 0635-01-C6-04-FG-0713-02_01 0635-01-C6-04-FG-0714-02_00 0635-01-C6-04-FG-0716-01_00 STDS-01-MS-03-603_01

0635-01-C6-04-FG-0710-03_01 0635-01-C6-04-FG-0711-01_00 0635-01-C6-04-FG-0713-01_00 0635-01-C6-04-FG-0714-01_00 0635-01-C6-04-FG-0715-01_01 0635-01-C6-04-FG-0716-02_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-4-D1-FG-710-N C6-2-D1-FG-712-N C6-4-D1-FG-714-N C6-4-D1-FG-716-N

C6-2-D1-FG-711-N C6-4-D1-FG-713-N C6-4-D1-FG-715-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II NPS 4 x 8.59mm WT, SCH 80, GR.359 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,684 kPa(g) Actual Maximum: 11,200 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: December 3, 2020 – 11:00 to 12:52 hours Test Ambient Temperature: -1.3 to 1.3 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 3 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA1-2020S19 Description: Fuel Gas System Module N-A-01 Spool Control Numbers:

A1-013; A1-014; A1-015; A1-016; A1-017; A1-018; A1-019; A1-020; A1-021; A1-022; A1-023; A1-024; A1-025

Reference Drawings:

0635-01-C6-04-FG-0717-01_00 0635-01-C6-04-FG-0718-01_01 0635-01-C6-04-FG-0720-01_00 0635-01-C6-04-FG-0721-01_00 0635-01-C6-04-FG-0722-01_01

0635-01-C6-04-FG-0717-02_00 0635-01-C6-04-FG-0719-01_00 0635-01-C6-04-FG-0720-02_00 0635-01-C6-04-FG-0721-02_00 0635-01-C6-04-703_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-4-D1-FG-717-N C6-2-D1-FG-719-N C6-4-D1-FG-721-N

C6-4-D1-FG-718-N C6-4-D1-FG-720-N C6-4-D1-FG-722-N

Pipe Data: NPS 1 x 4.55mm WT, SCH 80, ASTM A106B NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II Design Pressure: 6,274 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,684 kPa(g) Actual Maximum: 11,200 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: December 3, 2020 – 11:00 to 12:22 hours Test Ambient Temperature: -1.3 to 1.3 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 4 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA4-2020S20 Description: Fuel Gas System Module N-A-04 Spool Control Numbers: A4-015; A4-016; A4-046; A4-047;

Reference Drawings: 0635-01-C6-04-HG-0183-05_00 0635-01-C6-04-HG-0185-01_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-3-D1-HG-183-N

C6-2-D1-FG-185-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,932 kPa(g) Actual Maximum: 11,027 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 23, 2020 – 10:49 to 12:04 hours Test Ambient Temperature: 7.6 to 8.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 5 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA1-2020S22 Description: HC System Module N-A-01 Spool Control Numbers: A1-087; A1-088; A1-089; A1-090; A1-091; A1-092; A1-093

Reference Drawings: 0635-01-C6-04-HC-0270-01_00 0635-01-C6-04-HC-0271-05_00 0635-01-C6-04-HC-0272-02_00

0635-01-C6-04-HC-0270-02_00 0635-01-C6-04-HC-0272-01_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-1-D1-HC-270-N C6-2-D1-HC-272-N

C6-1-D1-HC-271-N

Pipe Data: NPS 1 x 4.55mm WT, SCH 80, ASTM A106B NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,684 kPa(g) Actual Maximum: 11,200 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: December 3, 2020 – 11:00 to 12:22 hours Test Ambient Temperature: -1.3 to 1.3 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 6 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA1-2020S23 Description: GV System Module N-A-01 Spool Control Numbers: A1-025; A1-053; A1-054; A1-063; A1-064; A1-065; A1-066; A1-067

Reference Drawings: 0635-01-C6-04-GV-0217-01_00 0635-01-C6-04-GV-0220-01_01 0635-01-C6-04-GV-0222-01_01 0635-01-C6-04-FG-0722-01_01

0635-01-C6-04-GV-0219-01_00 0635-01-C6-04-GV-0221-01_00 0635-01-C6-04-GV-0222-02_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-3-A1-GV-217-N C6-6-A1-GV-220-N C6-3-A1-GV-222-N

C6-6-A1-GV-219-N C6-3-A1-GV-221-N

Pipe Data: NPS 1 x 4.55mm WT, SCH 80, ASTM A106B NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 NPS 6 x 7.11mm WT, SCH 40, GR.359 CAT II Design Pressure: 1,800 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 2,700 kPa(g) Theoretical Maximum: 3,000 kPa(g) Actual Minimum: 2,723 kPa(g) Actual Maximum: 2,961 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: November 28, 2020 – 12:15 to 13:25 hours Test Ambient Temperature: -1 to -1.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 7 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA1-2020S24 Description: GV System Module N-A-01 Spool Control Numbers: A1-057; A1-058; A1-059; A1-060; A1-061

Reference Drawings: 0635-01-C6-04-GV-0218-01_01 0635-01-C6-04-GV-0218-03_01

0635-01-C6-04-GV-0218-02_01

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-1-E1-GV-218-N

Pipe Data: NPS 1 x 4.55mm WT, SCH 80, ASTM A106B Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,684 kPa(g) Actual Maximum: 11,200kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: December 3, 2020 – 11:00 to 12:22 hours Test Ambient Temperature: -1.3 to 1.3 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 8 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA1-2020S25 Description: GV System Module N-A-01 Spool Control Numbers: A1-057; A1-058; A1-059; A1-060; A1-061

Reference Drawings: 0635-01-C6-04-GV-0229-03_01 0635-01-C6-04-GV-0230-03_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-2-SA62S-GV-229-N

C6-2-SA62S-GV-230-N

Pipe Data: NPS 2 x 3.91mm WT, SCH 40, A312-TP316/316L Design Pressure: 1,035 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 1,555 kPa(g) Theoretical Maximum: 1,855 kPa(g) Actual Minimum: 1,679 kPa(g) Actual Maximum: 1,714 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 31, 2020 – 11:00 to 12:22 hours Test Ambient Temperature: -1.3 to 1.3 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 9 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA1-2020S26 Description: GV System Module N-A-01 Spool Control Numbers: A1-078

Reference Drawings: 0635-01-C6-04-GV-0232-03_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-4-SA62S-GV-232-N

Pipe Data: NPS 4 x 6.02mm WT, SCH 40, A312-TP316/316L Design Pressure: 1,090 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 1,635 kPa(g) Theoretical Maximum: 2,335 kPa(g) Actual Minimum: 1,679 kPa(g) Actual Maximum: 1,714 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 31, 2020 – 14:03 to 15:13 hours Test Ambient Temperature: 20.1 to 19 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 10 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA5-2020S27 Description: GV System Module N-A-05 Spool Control Numbers: A1-081

Reference Drawings: 0635-01-C6-04-GV-0233-03_00

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-2-D1-GV-233-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 Design Pressure: 6,274 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 9,415 kPa(g) Theoretical Maximum: 9,715 kPa(g) Actual Minimum: 9,565 kPa(g) Actual Maximum: 9,673 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 27, 2020 – 12:10 to 13:36 hours Test Ambient Temperature: 15.1 to 16.5 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 11 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA2-2020S29 Description: GV System Module N-A-02 Spool Control Numbers: A2-005

Reference Drawings: 0635-01-C6-04-GV-0225-02_01

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-6-SA62S-GV-225-N

Pipe Data: NPS 6 x 7.11mm WT, SCH 40, A312-TP316/316L Design Pressure: 1,090 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 1,635 kPa(g) Theoretical Maximum: 2,335 kPa(g) Actual Minimum: 2,130 kPa(g) Actual Maximum: 2,252 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 15, 2020 – 13:51 to 15:07 hours Test Ambient Temperature: 7.7 to 8 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 12 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA3-2020S30 Description: Fuel Gas System Module N-A-03 Spool Control Numbers: A3-001; A3-002

Reference Drawings: 0635-01-C6-04-FG-0710-01_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-4-D1-FG-710-N

Pipe Data: NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,133 kPa(g) Actual Maximum: 11,181 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 15, 2020 – 15:15 to 16:20 hours Test Ambient Temperature: 9.1 to 9.8 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 13 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA3-2020S31 Description: HC System Module N-A-03 Spool Control Numbers: A3-008; A3-009

Reference Drawings: 0635-01-C6-04-HC-0272-03_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-2-D1-HC-272-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,133 kPa(g) Actual Maximum: 11,181 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 15, 2020 – 15:15 to 16:20 hours Test Ambient Temperature: 9.1 to 9.8 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 14 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA5-2020S38 Description: GV System Module N-A-05 Spool Control Numbers: A1-069

Reference Drawings: 0635-01-C6-04-GV-0224-03_00

TC Representative: Andy Lewis

Pipe Information:

Line Numbers: C6-3-A1-GV-224-N

Pipe Data: NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 Design Pressure: 1,800 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 2,700 kPa(g) Theoretical Maximum: 3,000 kPa(g) Actual Minimum: 2,772.1 kPa(g) Actual Maximum: 2,915.5 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 28, 2020 – 11:47 to 13:04 hours Test Ambient Temperature: 18.8 to 17 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Andy Lewis (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 15 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENA4-2020S40 Description: GV System Module N-A-04 Spool Control Numbers: A4-008

Reference Drawings: 0635-01-C6-04-GV-0215-01_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-6-A1-GV-215-N

Pipe Data: NPS 6 x 7.11mm WT, SCH 40, GR.359 CAT II Design Pressure: 1,800 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 2,700 kPa(g) Theoretical Maximum: 3,000 kPa(g) Actual Minimum: 2,871.1 kPa(g) Actual Maximum: 2,987.6 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 23, 2020 – 14:46 to 16:01 hours Test Ambient Temperature: 24.2 to 21 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 16 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND1-2020S41 Description: HC/HG/UG System Module N-D-01 Spool Control Numbers: D1-001; D1-002; D1-007; D1-008; D1-009; D1-012; D1-013

Reference Drawings: 0635-01-C6-04-HC-0250-06_00 0635-01-C6-04-UG-0801-13_00

0635-01-C6-04-HG-0108-08_00

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-2-D1-HC-250-12E C6-2-D1-UG-801-N

C6-48-D1-HG-108-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,064 kPa(g) Actual Maximum: 11,162 kPa(g)

Test Medium: Water/Methanol Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 30, 2020 – 12:15 to 13:25 hours Test Ambient Temperature: 12.5 to 13.1 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 17 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND1-2020S42 Description: HG System Module N-D-01 Spool Control Numbers: D1-005; D1-006

Reference Drawings: 0635-01-C6-04-HG-0107-02_00

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-48-D1-HG-107-N

Pipe Data: NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,994 kPa(g) Actual Maximum: 11,171 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: September 28, 2020 – 15:10 to 16:20 hours Test Ambient Temperature: 18 to 20.4 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 18 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENE3-2020S44 Description: HG System Module N-E-03 Spool Control Numbers: E3-001; E3-002; E3-003; E3-004

Reference Drawings: 0635-01-C6-04-HG-0124-02_00 0635-01-C6-04-HG-0126-01_01

0635-01-C6-04-HG-0124-03_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-42-D1-HG-124-N

C6-2-D1-HG-126-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,002 kPa(g) Actual Maximum: 11,190 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 14, 2020 – 12:18 to 13:47 hours Test Ambient Temperature: 4 to 10 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 19 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENE1-2020S45 Description: HC System Module N-E-01 Spool Control Numbers: E1-001

Reference Drawings: 0635-01-C6-04-HC-0250-08_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-2-D1-HC-250-12E

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,044 kPa(g) Actual Maximum: 11,190 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 5, 2020 – 14:35 to 15:50 hours Test Ambient Temperature: 15.9 to 18.1 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 20 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENE1-2020S46 Description: HG System Module N-E-01 Spool Control Numbers: E1-005; E1-006

Reference Drawings: 0635-01-C6-04-HG-0108-09_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-48-D1-HG-108-N

Pipe Data: NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,784 kPa(g) Actual Maximum: 11,145 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 2, 2020 – 13:17 to 14:34 hours Test Ambient Temperature: 17.1 to 19.4 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 21 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENE1-2020S48 Description: HG System Module N-E-01 Spool Control Numbers: E1-002; E1-003; E1-007; E1-008

Reference Drawings: 0635-01-C6-04-HG-0106-06_01 0635-01-C6-04-HG-0109-03_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-48-D1-HG-106-N

C6-30-D1-HG-109-N

Pipe Data: NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,044 kPa(g) Actual Maximum: 11,190 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 5, 2020 – 14:35 to 15:50 hours Test Ambient Temperature: 15.9 to 18.1 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 22 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND1-2020S50 Description: HG System Module N-D-01 Spool Control Numbers: D1-010; D1-011

Reference Drawings: 0635-01-C6-04-HG-0109-02_00

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-30-D1-HG-109-N

Pipe Data: NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,023 kPa(g) Actual Maximum: 11,282 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 3, 2020 – 11:49 to 13:05 hours Test Ambient Temperature: 13.8 to 17.7 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 23 of 48

Test Number: Test Package No. STRIKENE2-2020S51 Description: High Pressure Utility Gas D1 Piping – On-module N-E-02 Spool Control Numbers:

E2-001; E2-002; E2-003; E2-006; E2-007; E2-008; E2-009

Reference Drawings:

0635-01-C6-04-UG-0801-09_00 0635-01-C6-04-UG-0805-05_00 0635-01-C6-04-HG-0106-05_00 0635-01-00-03-036_01

TC Representative: Daniel Hartwick

Pipe Information:

Line Numbers: C6-2-D1-UG-805-N C6-48-D1-HG-106-N Pipe Data: NPS 2 x 8.74mm WT, Sch 160, ATSM A333 Gr 6 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Mod. Design Pressure: 7100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,791 kPa(g) Actual Maximum: 11,080 kPa(g)

Test Medium: Water / Methanol 50/50 Test Location: Strike Whitecourt Fabrication Shop Test Date and Time: October 27, 2020 – 12:05 to 13:17 hours Test Ambient Temperature: 7.3 to 8.2 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Daniel Hartwick (TCE Representative) / Ted Fadish (Strike Representative)

Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 24 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENE2-2020S52 Description: HG System Module N-E-02

Spool Control Numbers: E2-004; E2-005

Reference Drawings: 0635-01-C6-04-HG-0108-10_01 0635-01-C6-04-HG-0129-01_00 0635-01-C6-04-HG-0131-01_00 0635-01-C6-04-HG-0133-01_00

0635-01-C6-04-HG-0108-11_00 0635-01-C6-04-HG-0130-01_00 0635-01-C6-04-HG-0132-01_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-48-D1-HG-108-N C6-16-D1-HG-130-N C6-16-D1-HG-132-N

C6-16-D1-HG-129-N C6-16-D1-HG-131-N C6-16-D1-HG-133-N

Pipe Data: NPS 16 x 7.10mm WT, SAW PIPE GR.414 CAT II NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure: Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,880 kPa(g) Actual Maximum: 10,934 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 15, 2020 – 12:25 to 13:39 hours Test Ambient Temperature: 2.8 to 5.9 degrees C Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 25 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND2-2020S53 Description: HG System Module N-D-02 Spool Control Numbers: D2-003; D2-004

Reference Drawings: 0635-01-C6-04-HG-0107-03_00

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-48-D1-HG-107-N

Pipe Data: NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,828 kPa(g) Actual Maximum: 10,952 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: November 10, 2020 – 12:30 to 13:40 hours Test Ambient Temperature: -0.1 to -1.8 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 26 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND2-2020S54 Description: HC System Module N-D-02 Spool Control Numbers: D2-001; D2-002

Reference Drawings: 0635-01-C6-04-Hc-0250-04_00

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-2-D1-HC-250-12E

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,828 kPa(g) Actual Maximum: 10,952 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: November 10, 2020 – 12:30 to 13:40 hours Test Ambient Temperature: -0.1 to -1.8 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 27 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND2-2020S55 Description: HG System Module N-D-02 Spool Control Numbers:

D2-006; D2-007; D2-008; D2-009; D2-010; D2-012; D2-013; D2-014; D2-015; D2-016

Reference Drawings: 0635-01-C6-04-HG-0108-04_02 0635-01-C6-04-HG-0108-06_01 0635-01-C6-04-HG-0157-01_00 0635-01-C6-04-HG-0158-01_01

0635-01-C6-04-HG-0108-05_02 0635-01-C6-04-HG-0108-07_00 0635-01-C6-04-HG-0157-02_01 0635-01-C6-04-HG-0109-01_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-48-D1-HG-108-N C6-1-D1-HG-157-N

C6-30-D1-HG-109-N C6-2-D1-HG-158-N

Pipe Data: NPS 1 x 4.55mm WT, SCH 80, ASTM A106B NPS 1 ½ x 7.14mm WT, SCH 160, ASTM A106B NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 11,076 kPa(g) Actual Maximum: 11,084 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: November 3, 2020 – 14:15 to 15:25 hours Test Ambient Temperature: 9.6 to 9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 28 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND2-2020S56 Description: UG/HG System Module N-D-02 Spool Control Numbers: D2-011; D2-021; D2-022

Reference Drawings: 0635-01-C6-04-HG-0109-01_01 0635-01-C6-04-UG-0801-15_00

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-30-D1-HG-109-N

C6-2-D1-UG-801-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,784 kPa(g) Actual Maximum: 11,320 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: November 1, 2020 – 11:06 to 12:12 hours Test Ambient Temperature: 13.8 to 15 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 29 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND5-2020S58 Description: GV System Module N-D-05 Spool Control Numbers: D5-008

Reference Drawings: 0635-01-C6-04-GV-0200-01_01

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-4-A1-GV-200-N

Pipe Data: NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II Design Pressure: 1,800 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 2,700 kPa(g) Theoretical Maximum: 3,000 kPa(g) Actual Minimum: 2,806 kPa(g) Actual Maximum: 2,931 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: October 28, 2020 – 11:17 to 12:30 hours Test Ambient Temperature: 22.8 to 23 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 30 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKEND5-2020S59 Description: FG/HC/HG System Module N-D-05

Spool Control Numbers:

D5-001; D5-002; D5-003; D5-004; D5-005; D5-006; D5-007; D5-009; D5-010; D5-011; D5-012; D5-013; D5-014; D5-015; D5-016; D5-017; D5-018; D5-019; D5-020, D5-022; D5-023; D5-024; D5-025; D5-026; D5-027; D5-028; D5-029; D5-031; D5-032; D5-033; D5-034; D5-036; C6-FG-MF-Y01; 1G032 (Y-Strainer)

Reference Drawings:

0635-01-C6-04-FG-0700-01_00 0635-01-C6-04-FG-0701-01_01 0635-01-C6-04-HC-0250-02_00 0635-01-C6-04-HC-0251-02_01 0635-01-C6-04-HC-0107-06_01 0635-01-C6-04-HC-0150-01_00 0635-01-C6-04-HC-0151-02_00 0635-01-C6-04-HC-0152-01_00 0635-01-C6-04-HC-0153-02_01 0635-01-C6-04-HC-0154-02_00 0635-01-C6-04-HC-0155-02_01 0635-01-C6-04-700_00

0635-01-C6-04-FG-0700-02_00 0635-01-C6-04-FG-0702-01_00 0635-01-C6-04-HC-0251-01_00 0635-01-C6-04-HC-0107-05_01 0635-01-C6-04-HC-0107-07_02 0635-01-C6-04-HC-0151-01_00 0635-01-C6-04-HC-0151-03_00 0635-01-C6-04-HC-0153-01_00 0635-01-C6-04-HC-0154-01_00 0635-01-C6-04-HC-0155-01_01 0635-01-C6-04-HC-0156-02_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-4-D1-FG-700-N C6-2-D1-FG-702-N C6-1-D1-HC-251-12E C6-48-D1-HG-107-N C6-4-D1-HG-151-N C6-2-D1-HG-153-N C6-1-D1-HG-155-N

C6-4-D1-FG-701-N C6-2-D1-HC-250-12E C6-2-D1-HG-150-N C6-3-D1-HG-152-N C6-3-D1-HG-154-N C6-3-D1-HG-156-N

Pipe Data: NPS 1 x 4.55mm WT, SCH 80, ASTM A106B NPS 1 ½ x 7.14mm WT, SCH 160, ASTM A106B NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,997 kPa(g) Actual Maximum: 11,009 kPa(g)

Test Medium: Water/Methanol 50/50 Mix Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: November 26, 2020 – 10:15 to 11:25 hours Test Ambient Temperature: -1.3 to -0.1 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 31 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB4-2021S62 Description: GV System Field Piping/N-A-01/N-A-02 Spool Control Numbers:

A1-073; A1-074; A1-076; A1-077; A1-079; A1-080; A2-006; A2-007; 000055; 000056; 000057; 000058; 000059; 000060; 000061; 000065

Reference Drawings:

0635-01-C6-04-GV-0225-01_01 0635-01-C6-04-GV-0225-04_01 0635-01-C6-04-GV-0226-02_01 0635-01-C6-04-GV-0229-02_01 0635-01-C6-04-GV-0229-05_01 0635-01-C6-04-GV-0230-02_01 0635-01-C6-04-GV-0230-05_01 0635-01-C6-04-GV-0232-04_01

0635-01-C6-04-GV-0225-03_01 0635-01-C6-04-GV-0226-01_01 0635-01-C6-04-GV-0229-01_01 0635-01-C6-04-GV-0229-04_01 0635-01-C6-04-GV-0230-01_01 0635-01-C6-04-GV-0230-04_01 0635-01-C6-04-GV-0232-02_01 0635-01-C6-04-GV-0232-05_01

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-6-SA62S-GV-225-N C6-2-SA62S-GV-229-N C6-4-SA62S-GV-232-N

C6-2-SA62S-GV-226-N C6-2-SA62S-GV-230-N

Pipe Data: NPS ½ x 3.73mm WT, SCH 80, A312-TP316/316L NPS 2 x 3.91mm WT, SCH 40, A312-TP316/316L NPS 4 x 6.02mm WT, SCH 40, A312-TP316/316L NPS 6 x 7.11mm WT, SCH 40, A312-TP316/316L Design Pressure: 1,035/1,090 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 1,635 kPa(g) Theoretical Maximum: 1,855 kPa(g) Actual Minimum: 1,738 kPa(g) Actual Maximum: 1,744 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: February 10, 2021 – 14:10 to 15:20 Test Ambient Temperature: 21.9 to 19.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Brent Adams (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 32 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB7-2021S64 Description: GV/HC System Field Piping/N-A-01/N-A-04 Spool Control Numbers:

A1-055; A1-056; A1-070; A1-071; A1-085; A1-086; A4-009; 052; 053; 054; 068; 069; 070; 071; 072; 073; 074; 075; 076; 077; 091

Reference Drawings:

0635-01-C6-04-GV-0201-01_01 0635-01-C6-04-GV-0203-01_00 0635-01-C6-04-GV-0205-01_00 0635-01-C6-04-GV-0207-01_00 0635-01-C6-04-GV-0209-01_00 0635-01-C6-04-GV-0212-01_00 0635-01-C6-04-GV-0217-02_00 0635-01-C6-04-GV-0224-01_00 0635-01-C6-04-GV-0224-04_00 0635-01-C6-04-GV-0234-01_00 0635-01-C6-04-HC-0252-02_01

0635-01-C6-04-GV-0202-01_00 0635-01-C6-04-GV-0204-01_00 0635-01-C6-04-GV-0206-01_00 0635-01-C6-04-GV-0208-01_00 0635-01-C6-04-GV-0211-01_00 0635-01-C6-04-GV-0215-02_00 0635-01-C6-04-GV-0217-03_00 0635-01-C6-04-GV-0224-02_00 0635-01-C6-04-GV-0224-05_00 0635-01-C6-04-GV-0234-02_00

TC Representative: Bernie Tabaka/Dan Hartwick

Pipe Information:

Line Numbers: C6-4-A1-GV-201-N C6-10-A1-GV-203-N C6-10-A1-GV-205-N C6-10-A1-GV-207-N C6-10-A1-GV-209-N C6-10-A1-GV-212-N C6-10-A1-GV-217-N C6-10-A1-GV-234-N

C6-10-A1-GV-202-N C6-10-A1-GV-204-N C6-10-A1-GV-206-N C6-10-A1-GV-208-N C6-10-A1-GV-211-N C6-10-A1-GV-215-N C6-10-A1-GV-224-N C6-4-A1-HC-252-12E

Pipe Data: NPS ½ x 3.73mm WT, SCH 80, ASTM A106B NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II NPS 6 x 7.11mm WT, SCH 40, GR.359 CAT II Design Pressure: 1,800 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 2,700 kPa(g) Theoretical Maximum: 2,900 kPa(g) Actual Minimum: 2,776 kPa(g) Actual Maximum: 2,791 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: February 23, 2021 – 12:22 to 13:32 Test Ambient Temperature: 12.0 to 14.0 degrees C

Fabricator/Contractor: Strike Group

Testing Supervisor: Bernie Tabaka/Dan Hartwick (TCE Representative) Justin Pierce/Ted Fadish (Strike Representative)

Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 33 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB8.5-2021S65 Description: FG System Field Piping Spool Control Numbers: 006; 007; 008; 009; 010; 011; 012; 241

Reference Drawings: 0635-01-C6-04-FG-0724-01_02 0635-01-C6-04-FG-0725-01_01

0635-01-C6-04-FG-0724-02_01 0635-01-C6-04-FG-0726-01_01

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-4-D1S-FG-724-N C6-1-D1S-FG-726-N

C6-1-D1S-FG-725-N

Pipe Data: NPS 1 x 4.55mm WT, SCH 80, A312-TP316/316L NPS 2 x 5.54mm WT, SCH 80, A312-TP316/316L NPS 4 x 6.02mm WT, SCH 40, A312-TP316/316L Design Pressure: 6,274 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 9,415 kPa(g) Theoretical Maximum: 10,115 kPa(g) Actual Minimum: 9,610kPa(g) Actual Maximum: 9,680kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: January 24, 2021 - 15:28 to 16:38 Test Ambient Temperature: 16.5 to 20.7 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Brent Adams (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 34 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB8-2021S66 Description: FG/GV System Field Piping/N-A-01 Spool Control Numbers: A1-082; A1-083; A1-084; 002; 003; 004; 005; 066; 067

Reference Drawings: 0635-01-C6-04-FG-0721-03_00 0635-01-C6-04-FG-0721-05_00 0635-01-C6-04-GV-0233-01_00 0635-01-C6-04-GV-0233-04_00

0635-01-C6-04-FG-0721-04_00 0635-01-C6-04-FG-0723-01_01 0635-01-C6-04-GV-0233-02_00 0635-01-C6-04-GV-0233-05_00

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-4-D1-FG-721-N C6-2-D1-GV-233-N

C6-1-D1-FG-723-N

Pipe Data: NPS ½ x 3.73mm WT, SCH 80, ASTM A106B NPS 1 x 4.55mm WT, SCH 80, ASTM A106B NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II Design Pressure: 6,274 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 9,415 kPa(g) Theoretical Maximum: 9,715 kPa(g) Actual Minimum: 9,572 kPa(g) Actual Maximum: 9,630 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: January 20, 2021 – 13:53 to 15:03 hours Test Ambient Temperature: 19.0 to 19.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 35 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB9A-2021S67 Description: GV/HC/HG/UG System Field Piping/N-A-01/N-A-04/M-D-02/N-D-06

Spool Control Numbers:

A1-062; A4-017; D2-025; D2-026; D6-010; 078; 079; 080; 081; 082; 083; 084; 085; 086; 087; 093; 096; 102; 103; 104; 138; 209; 210; 211; 212; 213; 214; 215; 216; 217; 218; 219; 220; 221; 222; 223; 224; 225; 226; 227;

Reference Drawings:

0635-01-C6-04-GV-0218-04_01 0635-01-C6-04-HC-0250-03_00 0635-01-C6-04-HC-0250-07_00 0635-01-C6-04-HC-0271-01_01 0635-01-C6-04-HC-0271-03_00 0635-01-C6-04-HG-0150-02_00 0635-01-C6-04-HG-0158-04_01 0635-01-C6-04-HG-0182-02_00 0635-01-C6-04-HG-0184-02_01 0635-01-C6-04-UG-0801-02_00 0635-01-C6-04-UG-0801-04_00 0635-01-C6-04-UG-0801-06_00 0635-01-C6-04-UG-0801-08_00 0635-01-C6-04-UG-0801-12_00 0635-01-C6-04-UG-0801-16_00 0635-01-C6-04-UG-0801-20_00 0635-01-C6-04-UG-0805-02_00 0635-01-C6-04-UG-0805-04_00

0635-01-C6-04-HC-0250-01_01 0635-01-C6-04-HC-0250-01_00 0635-01-C6-04-HC-0250-09_00 0635-01-C6-04-HC-0271-02_00 0635-01-C6-04-HC-0271-04_00 0635-01-C6-04-HG-0158-02_01 0635-01-C6-04-HG-0182-01_00 0635-01-C6-04-HG-0182-03_00 0635-01-C6-04-HG-0185-02_00 0635-01-C6-04-UG-0801-03_00 0635-01-C6-04-UG-0801-05_00 0635-01-C6-04-UG-0801-07_00 0635-01-C6-04-UG-0801-10_00 0635-01-C6-04-UG-0801-14_00 0635-01-C6-04-UG-0801-17_00 0635-01-C6-04-UG-0803-02_00 0635-01-C6-04-UG-0805-03_00 0635-01-C6-04-UG-0807-02_00

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-3-D1-HG-152-N C6-2-D1-HG-182-N C6-2-D1-HG-185-N C6-2-D1-HC-250-12E C6-2-D1-UG-801-N C6-2-D1-UG-805-N

C6-2-D1-HG-158-N C6-2-D1-HG-184-N C6-1-E1-GV-218-N C6-1-D1-HC-271-N C6-2-D1-UG-803-N C6-2-D1-UG-807-N

Pipe Data: NPS 1-1/2 x 7.13mm WT, SCH 160, ASTM A106B NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,704 kPa(g) Actual Maximum: 10,870 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: February 21, 2021, 12:25 – 13:35 hours Test Ambient Temperature: 12.6 to 13.7 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 36 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB9B-2021S68 Description: FG/HC/HG System Field Piping/N-D-02 Spool Control Numbers:

D2-023; D2-024; 001; 088; 089; 090; 094; 095; 097; 098; 099; 100; 101; 133; 134; 239; 240

Reference Drawings:

0635-01-C6-04-FG-0700-03_00 0635-01-C6-04-HC-0252-01_00 0635-01-C6-04-HG-0135-01_02 0635-01-C6-04-HG-0156-01_00 0635-01-C6-04-HG-0180-02_01 0635-01-C6-04-HG-0183-01_01 0635-01-C6-04-HG-0183-04_00

0635-01-C6-04-HC-0250-09_00 0635-01-C6-04-HG-0134-01_02 0635-01-C6-04-HG-0152-02_00 0635-01-C6-04-HG-0180-01_00 0635-01-C6-04-HG-0180-03_00 0635-01-C6-04-HG-0183-02_01 0635-01-C6-04-HG-0184-01_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-16-D1-HG-134-N C6-3-D1-HG-152-N C6-3-D1-HG-180-N C6-2-D1-HG-184-N C6-4-D1-FG-700-N

C6-16-D1-HG-135-N C6-3-D1-HG-156-N C6-3-D1-HG-183-N C6-4-D1-HC-252-12E

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II NPS 8 x 8.18mm WT, SCH 40, GR.359 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,831 kPa(g) Actual Maximum: 10,837 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: February 22, 2021, 14:18 to 15:28 hours Test Ambient Temperature: 14.1 to 18.2 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 37 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB10-2021S69 Description: HG System Field Piping/N-D-01/N-D-02/N-D-05/N-E-01 Spool Control Numbers: D1-003; D1-004; D2-005; D5-021; E1-004; 119; 121

Reference Drawings: 0635-01-C6-04-HG-0106-07_01 0635-01-C6-04-HG-0107-04_01 0635-01-C6-04-HG-0107-10_00

0635-01-C6-04-HG-0107-01_01 0635-01-C6-04-HG-0107-08_00 0635-01-C6-04-HG-0108-04_01

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-48-D1-HG-106-N C6-48-D1-HG-108-N

C6-48-D1-HG-107-N

Pipe Data: NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,997 kPa(g) Actual Maximum: 10,999 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: January 26, 2021, 12:35 to 13:45 hours Test Ambient Temperature: 11.7 to 14.0 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 38 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB11-2021S70 Description: HG System Field Piping Spool Control Numbers: 106; 107; 108; 238

Reference Drawings: 0635-01-C6-04-HG-0186-01_01 0635-01-C6-04-HG-0186-03_01

0635-01-C6-04-HG-0186-02_01 0635-01-C6-04-HG-0186-04_01

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-1-SF6S-HG-186-N

Pipe Data: NPS 1 x 4.55mm WT, SCH 80, A312-TP316/316L Design Pressure: 15,000 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 22,500 kPa(g) Theoretical Maximum: 23,200 kPa(g) Actual Minimum: 22,823 kPa(g) Actual Maximum: 22,887 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: January 25, 2021 – 13:55 to 15:05 hours Test Ambient Temperature: 20.6 to 21.2 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Logan Dirk (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 39 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKENFAB13-2021S72 Description: GV System Field Piping Spool Control Numbers: CN A4-009

Reference Drawings: 0635-01-C6-04-GV-0215-02_02 0635-01-C6-05-200_02 0635-01-C6-02-004_03

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-6-A1-GV-215-N

Pipe Data: NPS 6 x 7.11mm WT, SCH 40, GR.359 CAT II Design Pressure: 1,800 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 2,700 kPa(g) Theoretical Maximum: 2,900 kPa(g) Actual Minimum: 2,755 kPa(g) Actual Maximum: 2,835 kPa(g)

Test Medium: Water Test Location: Strike Group Fabrication Shop, Whitecourt, AB Test Date and Time: March 2, 2021 – 14:00 to 15:10 hours Test Ambient Temperature: 17.0 to 20.0 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Ted Fadish (Strike Representative)

Comments: No leaks were observed throughout the duration of this test. GV-0215 re-tested after addition of pup and o’let

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 40 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKE-2021S76 Description: HG System Field Piping Spool Control Numbers: 130; 131; 132

Reference Drawings: 0635-01-C6-04-HG-0124-01 _00 0635-01-C6-05-100_01 0635-01-C6-02-003_02

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-42-D1-HG-124-N

Pipe Data: NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,978 kPa(g) Actual Maximum: 11,229 kPa(g)

Test Medium: Water / Methanol Test Location: Nordegg CS C6 Unit Addition Test Date and Time: March 24, 2021, 12:35 to 16:41 hours Test Ambient Temperature: 3.2 to 9.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Noel Harvey (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 41 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKE-2021S77 Description: HG System Field Piping – Compressor Discharge to Pipeline Spool Control Numbers:

124; 125; 126; 127; 128; 129; 235; F1-001; F1-002; F1-003; F1-004; F2-008; F2-009; F2-010; F2-012; F2-013; F2-014; F2-0015

Reference Drawings:

0635-01-C6-04-HG-0108-12_01 0635-01-C6-04-HG-0108-13_01 0635-01-C6-04-HG-0134-01_02 0635-01-C6-04-HG-0135-01_02 0635-01-C6-04-HG-0139-01_00 0635-01-C6-04-HG-0139-02_00 0635-01-C6-04-HG-0139-03_01 0635-01-C6-04-HG-0141-01_00 0635-01-C6-04-HG-0141-02_00

0635-01-C6-04-HG-0141-03_01 0635-01-C6-04-HG-0143-01_00 0635-01-C6-04-HG-0143-02_00 0635-01-C6-04-HG-0143-03_01 0635-01-C6-05-100_01 0635-01-C6-02-002_02 0635-01-C6-02-006_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-3-D1-HG-108-N C6-3-D1-HG-141-N C6-3-D1-HG-143-N C6-16-D1-HG-134-N

C6-16-D1-HG-135-N C6-16-D1-HG-139-N C6-42-D1-GP-144-N C6-48-D1-HG-108-N

Pipe Data: NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 NPS 16 x 7.10mm WT, SAW PIPE GR.414 CAT II NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,811 kPa(g) Actual Maximum: 11,123 kPa(g)

Test Medium: Water Test Location: Nordegg CS C6 Unit Addition Test Date and Time: April 20, 2021, 13:05 to 16:05 hours Test Ambient Temperature: 12.9 to 16.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Noel Harvey (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 42 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKE-2021S78 Description: HG System Field Piping – Compressor Suction to Pipeline Spool Control Numbers:

109; 110; 111; 112; 113; 114; 115; 116; 117; 118; F3-001; F3-002; F3-003; F3-004; F4-001; F4-002; F4-003; F4-004; F4-005; F4-006; F4-007 ;F4-008

Reference Drawings:

0635-01-C6-04-HG-0101-01_00 0635-01-C6-04-HG-0101-02_00 0635-01-C6-04-HG-0101-03_01 0635-01-C6-04-HG-0103-01_00 0635-01-C6-04-HG-0103-02_00 0635-01-C6-04-HG-0103-03_01 0635-01-C6-04-HG-0105-01_00 0635-01-C6-04-HG-0105-02_00

0635-01-C6-04-HG-0105-03_01 0635-01-C6-04-HG-0106-01_01 0635-01-C6-04-HG-0106-02_01 0635-01-C6-04-HG-0106-03_00 0635-01-C6-04-HG-0106-04_00 0635-01-C6-05-100_01 0635-01-C6-02-001_02 0635-01-C6--02-003_02

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-3-D1-HG-101-N C6-3-D1-HG-103-N C6-3-D1-HG-105-N C6-30-D1-GP-104-N

C6-42-D1-HG-100-N C6-42-D1-GP-102-N C6-48-D1-HG-106-N

Pipe Data: NPS 1-1/2 x 7.13mm WT, SCH 160, ASTM A106B NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,811 kPa(g) Actual Maximum: 11,123 kPa(g)

Test Medium: Water / Methanol Test Location: Nordegg CS C6 Unit Addition Test Date and Time: April 20, 2021, 13:05 to 16:05 hours Test Ambient Temperature: 12.9 to 16.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Noel Harvey (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 43 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKE-2021S89

Description: HG System – Interconnect Line Between Compressor Bldg Suction and C6-PV-2708

Spool Control Numbers: 101; 246

Reference Drawings: 0635-01-C6-04-HG-0180-03_00 0635-01-C6-04-HG-0188-01_00

0635-01-C6-05-101_02 0635-01-C6-02-004_03

TC Representative: Dan Hartwick

Pipe Information:

Line Numbers: C6-2-D1-HG-188-N C6-3-D1-HG-180-N

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,997 kPa(g) Actual Maximum: 10,999 kPa(g)

Test Medium: Water / Methanol Test Location: Nordegg CS C6 Unit Addition Test Date and Time: January 26, 2021, 12:35 to 13:45 hours Test Ambient Temperature: 11.7 to 14.0 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Dan Hartwick (TCE Representative) / Justin Pierce (Strike Representative) Comments: No leaks were observed throughout the duration of this test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 44 of 48

Hydrostatic Test Details Test Number: Test Package No. STRIKE-2021S90 Description: HC System – HC Line to the Drain Tank Spool Control Numbers: CN 088; CN 089

Reference Drawings: 0635-01-C6-04-HC-0252-01_00, 0635-01-C6-04-HC-0250-09_00

0635-01-C6-02-003_02 0635-01-C6-05-250_01

TC Representative: Bernie Tabaka

Pipe Information:

Line Numbers: C6-4-D1-HC-252-I2E

Pipe Data: NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II Design Pressure: 7,100 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 10,650 kPa(g) Theoretical Maximum: 11,350 kPa(g) Actual Minimum: 10,978 kPa(g) Actual Maximum: 11,229 kPa(g)

Test Medium: Water Test Location: Nordegg CS C6 Unit Addition Test Date and Time: March 24, 2021, 13:45 to 15:05 hours Test Ambient Temperature: 3.2 to 9.9 degrees C

Fabricator/Contractor: Strike Group Testing Supervisor: Bernie Tabaka (TCE Representative) / Noel Harvey (Strike Representative)

Comments: No leaks were observed throughout the duration of this test. HC-0252 re-tested after field modification for alignment

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 45 of 48

Hydrostatic Test Details Test Number: Test Package No. PEERLESS C6-HG-MS-Y01 (8258-1) Description: Scrubber and Drain Piping Spool Control Numbers:

8258-1; 8258-1U; 8258-1S; 8258-1R; 8258-1Q; 8258-1P; 8258-1N; 8258-1M; 8258-1L; 8258-1K; 8258-1J; 8258-1T; 8258-1B; 8258-1C

Reference Drawings: 8258-1; 8258-1U; 8258-1S; 8258-1R; 8258-1Q; 8258-1P; 8258-1N; 8258-1M; 8258-1L; 8258-1K; 8258-1J; 8258-1T; 8258-1B; 8258-1C

0635-01-C6-02-003_02

TC Representative: Dean Labbe (Velosi Third Party Inspector)

Pipe Information:

Line Numbers: N/A

Pipe Data: NPS 1/2 x 4.75mm WT, SCH 160, ASTM A333 GR.6 NPS 1 x 6.35mm WT, SCH 160, ASTM A333 GR.6 NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 NPS 4 x 8.56mm WT, SCH 80, ASTM A333 GR.6 Design Pressure: 7,100/9,560 kPa(g)

Test Achieved Pressure:

Theoretical Minimum: 15,040 kPa(g) Theoretical Maximum: 15,175 kPa(g) Actual Minimum: 15,058 kPa(g) Actual Maximum: 15,175 kPa(g)

Test Medium: Water Test Location: Braeside Fabricators, Calgary Alberta Test Date and Time: September 28, 2020, 08:15 to 12:45 hours Test Ambient Temperature: 24 to 26 degrees C

Fabricator/Contractor: Braeside Fabricators Testing Supervisor: Dean Labbe (TCE Representative) / (Braeside Representative) Comments:

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 46 of 48

Hydrostatic Test Details

Test Number: MICROWATT C6-FE-3021

Description: Unit C6 NPS 2 Fuel Gas meter C6-FE-3021 – Factory Pressure Test

Spool Control Numbers: N/A

Reference Drawings: 0635-01-C6-02-101_02 0635-01-C6-04-FG-0710-03_01

TC Energy Representative:

-

Pipe Information: Line Numbers: C6-1-D1-FG-710-N

Valve Data: NPS 2, PN100, Flow meter

Design Pressure: 9998 kPa(g)

Test Pressure: 14997 kPa(g)

Test Achieved Pressure: 14997 kPa(g)

Test Medium: Water

Test Location: -

Test Date and Time: October 15, 2020; 1 hour

Test Ambient Temperature: - deg C

Fabricator/Contractor: Yokogawa

Testing Supervisor: D Cheaves (Yokogawa) / Doug Wall (Microwatt Quality Representative)

Comments: 1 hour

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 47 of 48

Hydrostatic Test Details

Test Number: Test for Valve Serial Number F002442652

Description: Unit C6 NPS 30 Hot Recycle Valve C6-FBV-2800 – Factory Valve Test

Spool Control Numbers: N/A (Factory Valve Test)

Reference Drawings: 0635-01-C6-02-004_03 0635-01-C6-04-HG-0109-01_01

TC Energy Representative:

E. Robert Fraser (Velosi Third Party Inspector)

Pipe Information: Line Numbers: C6-30-D1-HG-109-N

Valve Data: NPS 30, PN100, Globe Valve

Design Pressure: 10,343 kPa(g)

Test Pressure: 15,513 kPa(g)

Test Achieved Pressure: 15,513 kPa(g)

Test Medium: Water

Test Location: Spartan Shop

Test Date and Time: September 8, 2020 – 08:50 to 13:02 hours

Test Ambient Temperature: 21.7 – 22.3 deg C

Fabricator/Contractor: Spartan Controls

Testing Supervisor: Dixie Crompton (Spartan) / E. Robert Fraser (Velosi)

Comments: No leak on Hydrostatic Test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021 Page 48 of 48

Hydrostatic Test Details

Test Number: Test for Valve Serial Number F002440969

Description: Unit C6 NPS 3 Compressor Vent Valve C6-FBV-2709 – Factory Valve Test

Spool Control Numbers: N/A (Factory Valve Test)

Reference Drawings: 0635-01-C6-02-004_03 0635-01-C6-04-HG-0183-05_00

TC Energy Representative:

E. Robert Fraser (Velosi Third Party Inspector)

Pipe Information: Line Numbers: C6-3-D1-HG-183-N

Valve Data: NPS 3, PN100, Control Valve

Design Pressure: 10,343 kPa(g)

Test Pressure: 15,513 kPa(g)

Test Achieved Pressure: 15,513 kPa(g)

Test Medium: Water

Test Location: Spartan Shop

Test Date and Time: February 6, 2020 – 19:36 to 20:37 hours

Test Ambient Temperature: 21.9 – 22.2 deg C

Fabricator/Contractor: Spartan Controls

Testing Supervisor: Bill McFarland (Spartan) / E. Robert Fraser (Velosi)

Comments: No leak on Hydrostatic Test.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (As Amended) Application for Leave to Open Nordegg CS

May 2021 Page 1 of 1

Standards and Specifications List

Name EDMS No. TEN-CP-BUILD-GL Corrosion Prevention Construction Standard (CAN-US-MEX) 1003439376 TEN-CP-DESGN-GL TEN Corrosion Prevention Design (CAN-US-MEX) 1003455877 TEN-MATL Materials Standard 1001755803 TEN-ME-HGCS-G Compressor Station High Pressure Gas Piping Design Standard (CAN US MEX) 1006335523

TEN-ME-OPPCS-G Compressor Station OPP Standard (CAN-US-MEX) 1006158290 TEN-NDT NDT Standard (CDN-US-MEX) 1001828336 TEN-PRES Pressure Testing Standard (CDN) 1001810598 TES-CO-EPU-GL Field-Applied External Liquid Coating Systems for Steel Pipe Specification (CAN-US-MEX) 3671710

TES-CO-FBE-GL External Fusion Bond Epoxy For Steel Pipe Specification (CAN-US-MEX) 3670892 TES-CO-PAINT-GL Paint Systems For Above Ground Facilities (Coastal And Non-Coastal) Specification (CAN-US-MEX) 3694704 TES-CT-EXC-GLE Excavation Specification (CDN-US-MEX) 5890120 TES-FITG-CIF Contoured Insert Fittings Specification (CDN-US-MEX) 4424021 TES-FITG-EC1 End Closures Specification (CDN-US-MEX) 3779256 TES-MA-EWPI-GL Electric-Welded Pipe Specification (CAN-US-MEX) 3670788 TES-MA-FITG-GL Carbon Steel Butt-Welding Fittings Specification (CAN-US-MEX) 3671270 TES-MA-FLGEC-GL Carbon Steel Butt-Welding Flanges Specification (CAN) 3671966 TES-MA-SAWPI-GL Double Submerged Arc Welded Pipe Specification (CAN-US-MEX) 3776714 TES-MATL-COMP Materials Requirements of Pressure Containing Equipment Components Specification (CAN-US-MEX) 8071725

TES-MATL-MD1 Piping System Materials for Pipeline, Compression and Metering Facilities (CDN-US-MEX) 3764909 TES-MA-VALV-G Steel Valves for Gas Service Specification (CAN-US-MEX) 1001891682 TES-ME-CV-GL Control Valve Equipment and Design Specification (CAN-US-MEX) 1001969647 TES-ME-PV1-GLE Pressure Vessels Specification (CAN-US-MEX) 6406 TES-ME-STRCO-G Pipe Stress Engineering Analysis and Design of Compressor Stations (CAN-US-MEX) 7697565

TES-NDT-RT Radiographic Examination of Welds Specification (CDN) 3671368 TES-WELD-PL Welding of Pipelines and Tie-ins Specification (CDN) 3670960 TES-WL-AS-GL Welding of Assemblies and Station Piping Specification (CAN) 3670962

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (As Amended) Application for Leave to Open Nordegg CS

May 2021

Page 1 of 2

Summary of Pipe Manufacturers

Pipe Size Pipe Description Pipe Heat No. Pipe Manufacturer

NPS ½ NPS ½ x 3.73mm WT, SCH 80, ASTM A106B 607182 BENTELER

NPS ½ NPS ½ x 3.73mm WT, SCH 80, ASTM A106B 617308 BENTELER

NPS ½ NPS ½ x 3.73mm WT, SCH 80, A312-TP316/316L 130508D02 CHANGSHU WALSIN

NPS 1 NPS 1 x 4.55mm WT, SCH 80, ASTM A106B 618591 BENTELER NPS 1 NPS 1 x 4.55mm WT, SCH 80, A312-TP316/316L 11U730 CHANGSHU

WALSIN

NPS 1 ½ NPS 1 ½ x 7.14mm WT, SCH 160, ASTM A106B 179084 VALLOUREC

NPS 1 ½ NPS 1 ½ x 7.14mm WT, SCH 160, ASTM A106B 619103 BENTELER

NPS 2 NPS 2 x 5.54mm WT, SCH 80, A312-TP316/316L 11V382 CHANGSHU WALSIN

NPS 2 NPS 2 x 3.91mm WT, SCH 40, A312-TP316/316L F727142 NSSMC NPS 2 NPS 2 x 3.91mm WT, SCH 40, A312-TP316/316L F727143 NSSMC NPS 2 NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 182281 VALLOUREC NPS 2 NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 11914 TENARIS NPS 2 NPS 2 x 8.74mm WT, SCH 160, ASTM A333 GR.6 11915 TENARIS NPS 3 NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 48666 TENARIS NPS 3 NPS 3 x 5.49mm WT, SCH 40, ASTM A333 GR.6 144837 VALLOUREC NPS 4 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II 144837 VALLOUREC NPS 4 NPS 4 x 6.02mm WT, SCH 40, A312-TP316/316L 11V381 CHANGSHU

WALSIN NPS 4 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II 96804 TENARIS NPS 4 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II 92426 TENARIS NPS 4 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II 61F08014 THAI BENKAN

NPS 4 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II 49004 VALLOUREC

NPS 4 NPS 4 x 8.59mm WT, SCH 80, GR.359 CAT II 181837 TENARIS

NPS 4 NPS 4 x 6.02mm WT, SCH 40, ASTM A333 GR.6 183244 VALLOUREC

NPS 4 NPS 4 x 6.02mm WT, SCH 40, GR.359 CAT II 182281 VALLOUREC

NPS 6 NPS 6 x 7.11mm WT, SCH 40, A312-TP316/316L 11V778 CHANGSHU WALSIN

NPS 6 NPS 6 x 7.11mm WT, SCH 40, GR.359 CAT II 181281 VALLOUREC

NPS 12 NPS 12 x 10.31mm WT, SCH 40, GR.359 CAT II 96510 TENARIS NPS 12 NPS 12 x 10.31mm WT, SCH 40, GR.359 CAT II 97015 TENARIS NPS 16 NPS 16 x 7.10mm WT, SAW PIPE GR.414 CAT II ZZ1633 NPS 30 NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II G01354 NIPPON STEEL

CORP NPS 30 NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II G01355 NIPPON STEEL

CORP

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (As Amended) Application for Leave to Open Nordegg CS

May 2021

Page 2 of 2

NPS 30 NPS 30 x 11.40mm WT, SAW PIPE GR.483 CAT II G01356 NIPPON STEEL CORP

NPS 42 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II G07311 NIPPON STEEL CORP

NPS 42 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II G08190 NIPPON STEEL CORP

NPS 42 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II G17840 NIPPON STEEL CORP

NPS 42 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II G01207 NIPPON STEEL CORP

NPS 42 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II G01206 NIPPON STEEL CORP

NPS 42 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II G00440 NIPPON STEEL CORP

NPS 42 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II G00438 NIPPON STEEL CORP

NPS 42 NPS 42 x 26.20mm WT, SAW PIPE GR.483 CAT II 9212426 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211423 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211426 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211427 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211433 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211435 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211501 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211515 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211517 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211521 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211522 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9211530 NIPPON STEEL CORP

NPS 48 NPS 48 x 26.20mm WT, SAW PIPE GR.483 CAT II 9212023 NIPPON STEEL CORP

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021

Page 1 of 2

Summary of Piping, Welds, and Valves Not Tested Following Installation

For a summary of piping, welds and valves not subject to pressure testing following installation, please see below. There was no non-pressure tested welds associated with this LTO Application.

Summary of Piping, Welds and Valves Not Subjected to a Pressure Test Following Installation and Justification for Not Pressure Testing

Item Rationale Control Valve C6-FBV-2800 (Unit C6 Hot Recycle Valve)

Item has been shop (Manufacturer) tested in test “Spartan_C6-FBV-2800” and a field hydrotest is considered redundant to the shop test as it will not provide additional information. Due to the sensitivity and complexity of the item/assembly, a field hydrotest would negatively affect the devices, components calibration or damage to the components. No modifications were made to the assembly and/or single item after testing was completed.

Control Valve C6-FBV-2709 (Unit C6 Vent Valve)

Item has been shop (Manufacturer) tested in test “Spartan_C6-FBV-2709” and a field hydrotest is considered redundant to the shop test as it will not provide additional information. Due to the sensitivity and complexity of the item/assembly, a field hydrotest would negatively affect the devices, components calibration or damage to the components. No modifications were made to the assembly and/or single item after testing was completed.

Untested Spacer Rings: SN:4500284822/12/2 ISO:0635-01-00-04-GP-0104-03 SN:4500284822/1/4 ISO:0635-01-00-04-GP-0100-03 SN:4500284822/12/1 ISO:0635-01-00-04-GP-0138-01 SN:4500284822/1/3 ISO:0635-01-00-04-GP-0140-01 SN:4500284822/1/2 ISO:0635-01-00-04-GP-0142-01 SN:4500296169/2/2 ISO:0635-01-C6-04-HG-0106-04 SN: 4500284822/12/4 ISO: 0635-01-C6-04-HG-0109-01 SN:4500296169/2/1 ISO:0635-01-C6-04-HG-0108-12

Testing of this item has been accounted for in the calculation and/or burst design of the product. The component carries a pressure rating established through applicable CSA, API, ASME/ANSI standards, Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. (MSS) or by pressure design requirements as described in 4.3.12.1 of CSA Z662.

NOVA Gas Transmission Ltd. 2021 NGTL System Expansion Project

Order XG-001-2020 (as amended) Application for Leave to Open Nordegg CS

May 2021

Page 2 of 2

Item Rationale PSV list C6-PSV-0050 C6-PSV-0061 C6-PSV-0062 C6-PSV-0063 C6-PSV-0064 C6-PSV-0065 C6-PSV-3004 C6-PSV-3019 C6-PSV-3017 C6-PSV-3021 C6-PSV-3027 C6-PSV-3029 C6-PCV-3013 C6-PCV-3015

Engineering Assessment as per CSA Z662_2019 Clause 8.1.7

Restriction Orifice C6-FO-2709

Testing of this instrumentation related item has been accounted for in the calculation and/or burst design of the product. The component carries a pressure rating established through applicable CSA, API, ASME/ANSI standards, Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. (MSS) or by pressure design requirements as described in 4.3.12.1 of CSA Z662.

Field Fit Piping - within test packs: STRIKE_2021S25 STRIKE_2021S26 STRIKE_2021S62 STRIKE_2021S64 STRIKE_2021S65 STRIKE_2021S66 STRIKE_2021S67 STRIKE_2021S68 STRIKE_2021S69 STRIKE_2021S70 STRIKE_2021S72 STRIKE_2021S76 STRIKE_2021S90

Piping has been shop tested and a field hydrotest after installation would not provide additional information. No modifications were made to the assembly and/or single item after testing was completed. This piping is field fit piping. It connects the piping modules used to assemble the majority segment of this Project.

Fuel Gas Meter C6-FE-3021 Item has been shop (Manufacturer) tested in test “Microwatt Yokogawa_C6-FE-3021” and a field hydrotest is considered redundant to the shop test as it will not provide additional information. Due to the sensitivity and complexity of the item/assembly, a field hydrotest would negatively affect the devices, components calibration or damage to the components. No modifications were made to the assembly and/or single item after testing was completed.

STRIKE GROUPRECEIVED

MAY 15, 2020

N-F-04

N-F-04

N-F-03

N-F-03

N-F-04 N-F-04TEST PACK STRIKEFAB9A_2021S67

STRIKE_2021S78

STRIKE_2021S73

STRIKE_2021S75

STRIKE_2021S74

STRIKE_2021S78

STRIKE_2021S78

STRIKE_2021S78

Included in testDouble faced blindsSN: 4500284822/11/1Spacer rings untested to be installedSN:4500284822/12/2ISO:0635-01-00-04-GP-0104-03

Included in testDouble faced blindsSN: 4500284822/2/3Spacer rings untested to be installedSN:4500284822/1/4ISO:0635-01-00-04-GP-0100-03

Included in testDouble faced blindsSN: 4500284822/2/1Spacer rings tested with STRIKENE3_2020S44SN:4500284822/8/1ISO:0635-01-00-04-GP-0102-03

The piping in the following tests are covered under Exemption Orders XG-001-2020 and AO-001-XG-001-2020:

STRIKE_2021S73 STRIKE_2021S74 STRIKE_2021S75

STRIKE GROUPRECEIVED

MAY 15, 2020

N-F-01

N-F-01

N-F-02 N-F-02

N-F-02

N-F-02

N-E-02

STRIKE_2021S77

STRIKENF1-2-3-4_2020S37

STRIKENE2_2020S51STRIKEFAB9A_2021S67

STRIKE_2021S77

STRIKE_2021S77

STRIKE_2021S77

STRIKE_2021S77

STRIKE_2021S73

STRIKE_2021S74

STR

IKEN

F2_2

020S

61

STRIKE_2021S75

STR

IKEN

F2_2

020S

61

STRIKE_2021S91

STRIKE_2021S91

Included in testDouble faced blindsSN: 4500284822/2/2Spacer rings untested to be installedSN:4500284822/1/3ISO:0635-01-00-04-GP-0140-01

Included in testDouble faced blindsSN: 4500284822/10/1Spacer rings untested to be installedSN:4500284822/1/2ISO:0635-01-00-04-GP-0142-01

Included in testDouble faced blindsSN: 4500284822/4/1Spacer rings untested to be installedSN:4500284822/12/1ISO:0635-01-00-04-GP-0138-01

STRIKE_2020S61

The piping in the following tests are covered under Exemption Orders XG-001-2020 and AO-001-XG-001-2020:

STRIKE_2021S73 STRIKE_2021S74STRIKE_2021S75

STRIKE GROUPRECEIVED

MARCH 31, 2020

1

1 00798-STR-DM-RFI-0232

RL_05

2

2 00798-STR-DM-RFI-0198

Vessel and bridle insulation revised per vendor drawings50 50

Y02 3

00798-STR-DM-RFI-02903

1/2 1/23 3

STRIKE GROUPRECEIVED

MARCH 31, 2020

N-D-01N-D-01 Mod N-D-1 STRIKEND1 - 2020S42

Mod N-D-1 STRIKEND1 - 2020S50

Mod N-E-1 STRIKENE1 - 2020S48

Mod N-E-2 STRIKENE2 - 2020S51

Mod N-D-2 STRIKEND2 - 2020S53

N-E-

01

N-D-01N-D-01N-

E-01

N-E-

01

N-E-2

N-D-

02

STRIKEFAB10-2021S69

STRIKEFAB7_2020S64

STRIKEFAB10_2021S69

STRIKEFAB7-2021S64

STR

IKEF

AB7_

2021

S64

STRIKEFAB9A-2021S67

STRIKEFAB9A_2021S67

STRIKEFAB9B_2021S68

STRIKEFAB9B-2020S68STRIKE_2021S76STRIKE_2021S78

1 1/2"

STRIKEND1_2020S50

STRIKEFAB10_2021S69STRIKEFAB10_2021S69

STRIKEND1_2020S48 STRIKEND1_2020S42

STRIKE_2021S76

STRIKE_2021S78

STRIKE_2021S90

STRIKE_2021S90

Included in testDouble faced blindsSN: 4500296169/3/1Spacer rings untested to be installedSN:4500296169/2/2ISO:0635-01-C6-04-HG-0106-04

UntestedSpacer ringsSN: 4500284822/12/40635-01-C6-04-HG-0109-01

PEERLESS C6-HG-MS-Y01 (8258-1)

³

STRIKE GROUPRECEIVED

OCTOBER 30, 2020

1-D1T1"

RL_03

C6ZSC2708

C6ZSO2708

C6-2-D1-HG-187-N2"

NO

3x2

C6PV

2708

C6FN

2708

2x3/4

2x1

2x1FC

C6-

2-D

1-H

G-1

88-N

PRESSURIZATION

1/2-D1T

1/2"

3X2

NO2"

C6FO

2708 1/2-D1T

BAROMETRIC DAMPER(PROVIDE BY SITE

CONTRACTOR)

PSV SHALL BE VENTED TO A SAFE LOCATION5

TEST PACK STRIKEFAB9B-2021S68

X

X

00798-STR-DM-RFI-0179

00798-STR-DM-RFI-01781

2

2

00798-STR-DM-RFI-0123

3

1

1

1

3

33

33

3

3

4

4

13

13

4 00798-STR-DM-RFI-024800798-TC-Z-DCN-0040500798-TC-M-DCN-00546

6

5

5

1" 1"

3"x1" 3"x1"

7 AS PER ISOMETRIC

7

333

STRIKEFAB9A_2021S67

STRIKEFAB9A_2021S67

STRIKEFAB9A_2021S67

STRI

KEFA

B9A_

2021

S67

STRI

KEFA

B9A_

2021

S67

STRI

KEFA

B9A_

2021

S67

STRIKEFAB7_2021S64

STRI

KEFA

B7_2

021S

72

STRIKENA4_2020S40

STRI

KENA

4_20

20S4

0

STRIKENA4_2020S20

STRIKENA4_2020S20 STRIKENA4_2020S20

STRIKEND2_2020S55STRIKEND2_2020S56

STRIKEND2_2020S55

STRIKEND2_2020S56

STRIKEND2_2021S57

STRIKEFAB9B_2021S68

STRIKEFAB9B_2021S68

STRIKEFAB9B_2021S68

STRIKEFAB9B_2021S68

"

STRIKEFAB9B_2021S68

STRIKEFAB9B_2021S68

STRIKEND3_2020S15

STRIKEND3_2020S15

STRIKEND3_2020S15

STRIKEND5_2020S59

212

STRIKE_2021S79

STRIKEFAB10_2021S69

STRIKEFAB10_2021S69

STRIKEFAB10_2021S69

STRIKEFAB10_2021S69

STRIKEFAB10_2021S69

STRIKEFAB10_2021S69

STRIKE_2021S80

STRIKE_2021S80STRIKE_2021S80

STRIKE_2021S80

STRIKE_2021S89

Included in testSpacer ringSN: 4500284822/12/50635-01-C6-04-HG-0109-01

Included in testSpacer ringSN: 4500284822/12/30635-01-C6-04-HG-0109-01

Tested Spec BlindHT: DZV0635-01-C6-04-HG-0154-01

Tested Spec BlindHT: DZV0635-01-C6-04-HG-0153-01

Tested Spec BlindHT: DZV0635-01-C6-04-HG-0184-01

Test"SPARTAN_C6-FBV-2709"

Test"SPARTAN_C6-FBV-2800"

The piping in the following tests will be covered in the final LTO Application:

STRIKE_2021S79STRIKE_2021S80STRIKE_2021S89

STRIKEFAB10_2021S72STRIKE_2021S89

SS

STRIKE GROUPRECEIVED

MARCH 31, 2020

1

00798-STR-DM-RFI-01791

RL_02

2

2 00798-STR-DM-RFI-0199

STRIKENE3_2020S44STRIKENE1_2020S46

STRI

KENE

3_20

20S4

4

STRI

KENE

1_20

20S4

6

STRIKEND1_2020S41

STRIKEND1_2020S41

Tested Spacer Ring untested installedSN:4500284822/1/1ISO:0635-01-C6-04-HG-0124-02

STRIKE GROUPRECEIVED

MARCH 31, 2020

N-E-

02

N-E-02

N-E-

02

N-E-

02

N-E-

02

N-E-

02

N-E-02

11

1

STRIKE_2021S77

00798-STR-DM-RFI-0001

STRIKEFAB9_2021S68

STRIKEFAB9_2021S68

STRIKEFAB9_2021S68

STRIKEFAB7_2021S64

STRIKEFAB7_2021S64

STRIKEFAB7_2021S64

STRIKEFAB7_2021S64

STRIKEFAB7_2021S64

STRIKEFAB7_2021S64

STRIKENE2_2020S52

RL_01

Included in testDouble faced blindsSN: 4500296169/3/2Spacer ring untested to be installedSN:4500296169/2/1ISO:0635-01-C6-04-HG-0108-12

STRIKE GROUPRECEIVED

MARCH 31, 2020

1

00798-STR-DM-RFI-01791

RL_01

STRIKEND5_2020S58 STRIKEND5_2020S59

STRIKEND5_2020S59

STRIKEND5_2020S59

STRIKEND5_2020S59

STRIKEND5_2020S58

STRIKEND2_2020S54

STRIKEND2_2020S54

STRIKEFAB9A_2021S67 STRIKEFAB9A_2021S67

STRIKENE1_2020S45

STRIKEFAB9A_2021S67

STRIKEFAB9A_2021S67

STRIKENE1_2020S45

STRIKEFAB9A_2021S67

STRIKEFAB9A_2021S67

STRIKEND1_2020S41

STRIKEND1_2020S41

STRIKE GROUPRECEIVED

MAY 15, 2020

1

22

BA-1

1

1/2"

4

3

00798-STR-DM-RFI-0207

00798-STR-DM-RFI-017900798-STR-DM-RFI-0194

1

2

00798-STR-DM-RFI-01963

NE-

14

NE-

14

C6PI

3013

NE-

14

NO

1/2"

NE-

14

NE-

14

C6PI

3015

NE-

14

NO

1/2"

4

4

4

44

4

N-A-01

N-A-01

N-A-01

N-A-

01

N-A-

01

N-A-

01

NO

N-A-01

N-A-01

N-A-01

N-A-01NO

N-A-01

N-A-

01

N-A-

01

N-A-01

N-A-01

STRIKEFAB7_2021S64

STRIKEFAB7-2021S64

STR

IKEF

AB9B

_202

1S68

STRIKEFAB9B-2021S68

STR

IKEN

A3_2

020S

30

RL_01

STRIKENA1_2020S18STRIKENA1_2020S19

1

STRIKENA1_2020S23STRIKENA1_2020S24STRIKENA1_2020S30

Tested "Microwatt Yokogawa_C6-FE-3021"

The Auxiliary piping is coveredunder Exemption Orders XG-001-2020 andAO-001-XG-001-2020.

N-A-

01

N-A-

01

N-A-

01

N-A-

01

N-A-

01

N-A-

01 N-A-

01

N-A-

01

N-A-01

N-A-

03

N-A-

03

N-A-01

N-A-

01

N-A-01

N-A-

01

N-A-01N-A-

01

N-A-

01

N-A-

01N

N

N-A-01N-A-01

N-A-

01

N-A-01

VALVE BODY BLEEDS IN GAS PIPING ARE NOT REQUIRED TO BE VENTED OUTSIDE.

00798-STR-DM-RFI-017200798-STR-DM-RFI-0179

1

1

2

00798-STR-DM-RFI-01673

2

BA-92

3

N-A-

05

N-A-

05N-A-

01

44

4 00798-STR-DM-RFI-0168

41/2"

1/2"1/2"

1/2"4

1/2"

4

STRIKEFAB8.5_2021S65

STRIKEFAB8_2021S66

N-A-

05

N-A-

05

STRIKEFAB7_2021S64

STRIKEFAB7_2021S64

1

TEST PACK STRIKEFAB9A_2021S68

STRIKEFAB9B-2021S68

STRIKENA1-2020S23

STRIKENA1-2020S22

STRIKEFAB8-2021S66 STRIKEFAB8.5-2021S65

STRIKEFAB7-2021S64

STRIKENA1-2020S19

TEST PACK STRIKEFAB9B_2021S68

STRIKEFAB9A-2021S67

RL_01

STRIKEFAB7_2021S64

test of bleedring to beprovided infinal LTO

The Auxiliary piping is covered underExemption Orders XG-001-2020 and AO-001-XG-001-2020.

Field

Pipin

g

N-A

-04

Field

Pipin

g

N-A-04

N-A-02

N-A-02

N-A

-04

Field

Pipin

g N

-A-0

4

N-A

-04

Field

Pipin

g

N-A-04Field Piping

Field

Pipin

g N

-A-0

4

N-A-04 N-A-04

Mod N-A-2 STRIKENA2 - 2020S29

Shop STRIKEFAB4 - 2021S62

STRIKEFAB4_202S01

STR

IKEF

AB4_

2021

S62

STRIKEFAB4_2021S62

The Auxiliary piping is covered under Exemption Orders XG-001-2020 and AO-001-XG-001-2020.(lines highlighted here are vents, labelled "GV," off auxiliary pipingsystems but are included in this LTO because all "GV", ie gas ventpiping is included)

N-A

-04

N-A

-04

N-A

-04

N-A

-04

N-A-04

N-A-04

N-A

-04

N-A

-04

Mod N-A-1 STRIKENA1 - 2020S25

Mod N-A-1 STRIKENA1 - 2020S26

Mod N-A-5 STRIKENA5 - 2020S27

N-A-05

N-A-05

N-A

-01 N-A

-01

N-A

-01

N-A

-01

N-A

-01

N-A

-01

FIELD STRIKEFAB4-2021S62

STR

IKEF

AB4_

2021

S62

STR

IKEF

AB8.

5_20

21S6

5

FIELD STRIKEFAB8.5-2021S65

FIELD STRIKEFAB8-2021S66

STRIKEFAB8_2021S66

FIELD STRIKEFAB11-2021S70

STR

IKEF

AB11

_202

1S7

0

STR

IKEF

AB4_

2021

S62

STR

IKEF

AB4_

2021

S62

STR

IKEF

AB4_

2021

S62

STR

IKEF

AB4_

2021

S62

STRIKEFAB8_2021S66

STR

IKEF

AB8.

5_20

21S6

5

STRIKEFAB8.5_2021S65

The Auxiliary piping is covered underExemption Orders XG-001-2020 and AO-001-XG-001-2020.