    DISEO DE RESERVORIO DE 115.0DATOS :

    VOLUMEN (V) = 115.00ANCHO DE LA PARED (b) = 7.15

    ALTURA DEL AGUA (h) = 2.86BORDE LIBRE (B.L.) = 0.30

    ALTURA TOTAL (H) = 3.16PESO ESPECIFICO DEL AGUA (a) = 1,000.00PESO ESPECIFICO DEL TERRENO (t) = 1,800.00CAPACIDAD DE CARGA DEL TERRENO (t) = 1.50PESO ESPECIFICO DEL CONCRETO (c) = 2,400.00

    A) CALCULO DE MOMENTOS Y ESPESORES

    Los lmites de relacin de b/h son de 0.5 a 3.0b/h =

    y = 0 y = b/4

    b/h x/h Mx My Mx My0 0.00 584.84 0.00 163.76 280.72 514.66 116.97 187.15

    2.50 374.30 374.30 233.94 210.54 -46.79 116.97 23.39 93.571 -1,731.13 -350.90 -1,169.68 -233.94

    M = k x a x h3

    DEL CUADRO: Mx = 1,731.131 Kg-m.

    CALCULO DEL ESPESOR DE LA PARED:

    e = 6M

    ft x b

    DONDE :ft = 0.85(F'c)^ = 12.32F'c = 210.00 Kg/cm2.Mx = 1,731.13 Kg-m.My = 1,216.47 Kg-m.b = 100.00 cm.

    REMPLAZANDO VALORES EN (02) TENEMOS:

    e = 29.04 cm.

    PARA EL DISEO SE ASUME, QUE:e = 30.00 cm.

    CALCULO DEL ESPESOR DE LA LOSA DE CUBIERTA

  • 7/28/2019 CALCULO RESERVORIO 80

    2/35

    SE CALCULA COMO LOSA ARMADA EN DOS DIRECCIONES

    Espesor e = L/36

    L = b + ((2*e)/2)

    REMPLAZANDO VALORES EN (04):L = 7.45 m.

    LUEGO EN 03:Espesor e = 0.21 m.

    ASUMIENDO PARA EL PROYECTO

    Espesor e = 0.20 m.

    SEGN EL REGLAMENTO NACIONAL DE CONSTRUCCIONES, PARA LOSAS MACIZAS

    MA = MB = CW(L^2)

    DONDE: C = 0.036PESO PROPIO = 0,10 x 2400CARGA VIVAPESO TOTAL = Wtotal

    REEMPLAZANDO EN LA ECUACION 05:

    MA = MB

    CALCULO DEL PERALTE:

    d = MRb

    SIENDO:M = MA = MB = 1,258.80 kg-m.b = 100.00 cm.

    R = * fc * j * k

    n = 9.28k = 0.344

    j = 1 - k/3

    (1)n = (1)n = Es/Ec = (2.1 x 10^6)/(W^1.5 * Fy * (f'c)^)

    PARA W = 2.40 Tn/m3. Tn/m3.f'c = 210.00 kg/cm2. kg/cm2.Fy = 4,200.00 kg/cm2. kg/cm2.

    (2)k = 1/(1+fs/(nf'c))

  • 7/28/2019 CALCULO RESERVORIO 80

    3/35

    PARA fs = 1,400.00 kg/cm2.fc = 79.00 kg/cm2.

    EN LA ECUACION 08:j = 0.885

    EN LA ECUACION 09:

    R = 12.02

    REEMPLAZANDO VALORES EN 06:

    d = 10.23 cm.

    EL ESPESOR TOTAL (e), CONSIDERANDO UN RECUBRIMIENTO DE 2.5 CM.

    Recubrimiento ( r ) = 2.50 cm.

    e total = d + r e total = 12.73 cm.

    SIENDO: 0.13 < 0.20 m.

    PARA EL DISEO SE CONSIDERA:

    d = 17.50 cm.

    CALCULO DEL ESPESOR DE LA LOSA DE FONDO

    ASUMIENDO EL ESPESOR DE LA LOSA DE FONDO Y CONOCIDA LA ALTURA

    e' = 0.25 m.h = 2.86 m.

    PESO PROPIO DEL AGUA (h x a) =PESO PROPIO DEL CONCRETO (e' x c) =

    w =

    DEBIDO A LA ACCION DE LAS CARGAS VERTICALES ACTUANTES PARA UNA LUZ INTSE PRODUCEN LOS SIGUIENTES MOMENTOS:

    MOMENTO DE EMPOTRAMIENTO EN LOS EXTREMOS:

    M = -(W x L^2 /192) (09) M =

    MOMENTO EN EL CENTRO:

    M = W x L^2 /384 (10) M =

    CHEQUEO DEL ESPESOR DE LA LOSA:

    EL ESPESOR SE CHEQUEA POR MEDIO DEL METODO ELASTICO, CONSIDERANDO E

    e = 6M ft x b

  • 7/28/2019 CALCULO RESERVORIO 80

    4/35

    ft = 0.85(F'c)^ = 12.32F'c = 210.00 KG/CM2.M = 921.27 KG-Mb = 100.00 CM

    REMPLAZANDO EN LA ECUACION 11:e = 21.18

    21.18 < 25.00

    POR LO TANTO CONSIDERANDO EL RECUBRIMIENTO:

    r = 4.00PERALTE:

    d = 21.00

    B) DISTRIBUCION DE LA ARMADURA DEL RESERVORIO

    As = M

    fs x j x d

    DONDE:M = MOMENTO MAXIMO ABSOLUTO EN KG-M.fs = FATIGA DE TRABAJO EN KG/CM2.

    j = RELACION ENTRE LA DISTANCIA DE LA RESULTANTDE COMPRESION AL CENTRO DE LA GRAVEDAD DE

    d = PERALTE EFECTIVO EN CM.

    CALCULO DE LA ARMADURA DE LA PARED:

    M+ = 1,731.13 kg-m.M- = 1,216.47 kg-m.

    fs = 900.00 kg/cm2.n = 9.00 Valores recoe = 30.00 cm.r = 15.00 cm.d efectivo = 15.00

    j = 0.85k = 0.441b = 100.00 cm.

    R = * fs * j * k

    n = 9.58k = 0.46

    j = 1 - k/3

    (1)n = (1)n = Es/Ec = (2.1 x 10^6)/(W^1.5 * Fy * (f'c)^)

    PARA W = 2.40 Tn/m3. Tn/m3.f'c = 210.00 kg/cm2. kg/cm2.Fy = 4,200.00 kg/cm2. kg/cm2.

  • 7/28/2019 CALCULO RESERVORIO 80

    5/35

    (2)k = 1/(1+fs/(nf'c))

    PARA fs = 900.00 kg/cm2.f'c = 79.00 kg/cm2.

    EN LA ECUACION 08:

    j = 0.85EN LA ECUACION 09:

    R = 17.43

    REEMPLAZANDO VALORES EN 06:

    d = 1.00 cm.

    RESUMEN DEL CALCULO DEL ACER

    PARED LOSADESCRIPCION DE

    VERTICAL HORIZONTAL CUBIERTA

    Momento "M" (kg - m) 1,731.13 1,216.47 1,258.80

    Espesor Util "d" (cm.) 15.00 15.00 12.50

    fs (kg/cm2.) 900.00 900.00 1,400.00

    n 9.00 9.00 10.00

    f'c (kg/cm2.) 79.00 79.00 79.00

    k = 1/(1+ fs / (n x f'c)) 0.441 0.441 0.361

    j = 1 - (k/3) 0.853 0.853 0.880

    Area de Acero

    As = (100 x M)/(fs x j x d) (cm2.) 15.04 10.57 8.18

    C 0.0018 0.0018 0.0018

    b (cm.) 100 100 100

    e (cm.) 30 30 15

    Cuantia Mnima

    Asmn = C x b x e (cm2.) 5.4 5.4 2.7

    Area Efectiva de As2. (cm2.) 15.48 11.61 6.45

    Area Efectiva de Asmn2. (cm2.) 5.4 5.4 5.4

    de Acero 1/2" 1/2" 1/2"

    Distribucin (Aacero/Aacero total) 0.08 0.22 0.13

    C) CHEQUEO POR ESFUERZO CORTANTE Y ADHERENCIA

    CHEQUEO DE LA PARED

    (RESERVORIO DE 115.00 M3.)

  • 7/28/2019 CALCULO RESERVORIO 80

    6/35

    1. - ESFUERZO CORTANTE MAXIMA (V), SERA:

    V = (a x h^2) /2

    REEMPLAZANDO VALORES EN LA ECUACION 13:

    V = 4,089.80

    ESFUERZO CORTANTE NOMINAL

    v = V/(j x b x d)

    DATOS J = 7/8 = 0.875

    POR LO TANTO:v = 3.12

    EL ESFUERZO PERMISIBLE NOMINAL EN EL CONCRETO PARA MUROS NO EXCEDER

    Vmx = 0,02 * f'c

    Para f'c = 210.00 kg/cm2.

    Vmx = 4.20

    3.12 < 4.20

    2.- CHEQUEO POR ADHERENCIA

    ESFUERZO DE ADHERENCIA

    u = V /(o * J * d)

    SIENDO: o para 5,8 @ 13.15o para 5,8 @ 14.00 cm. = 112.71

    V = 4,089.80j = 0.85d = 12.50

    u = 3.42

    ESFUERZO PERMISIBLE POR ADHERENCIA

    umx = 0,05 * f'c

    f'c = 175.00

    umx = 8.75

    3.42 < 8.75

    CHEQUEO DE LA LOSA DE CUBIERTA

  • 7/28/2019 CALCULO RESERVORIO 80

    7/35

    1. - ESFUERZO CORTANTE MAXIMA (V), SERA:

    V = W * S /3

    W = 630.00S = b = 7.15

    Remplazando

    V = 1501.50

    2. - CORTANTE UNITARIO (v), SERA:

    v = V / b*d

    b = 100.00d = 17.50

    v = 0.86

    3. - ESFUERZO CORTANTE MAXIMA UNITARIO (vmx), SERA:

    vmx = 0,29 * (f'c^(1/2))

    vmx = 3.84

    0.86 < 3.84

    12.072.- CHEQUEO POR ADHERENCIA

    ESFUERZO DE ADHERENCIAu = V /(o * J * d)

    SIENDO: o para 3/8 @ 13.1514.00 cm. = 40.01

    V = 7.15j = 0.879d = 7.50

    u = 5.69

    ESFUERZO PERMISIBLE POR ADHERENCIA

    umx = 0,05 * f'c

    f'c = 175.00

    umx = 8.75

    5.69 < 8.75

  • 7/28/2019 CALCULO RESERVORIO 80

    8/35

    M3. VALORES DE LOS COEFICI

    m3.m. 2.864 y = 0 y = b/4

    m. b/h x/hm. Mx My Mx Mym. 0 0.000 0.025 0.000 0.014Kg/m3. 0.010 0.019 0.007 0.013Kg/m3. 3.00 0.005 0.010 0.008 0.010Kg/cm2. -0.033 -0.004 -0.018 0.000Kg/m3. 1 -0.126 -0.025 -0.092 -0.018

    0 0.000 0.027 0.000 0.013 0.012 0.022 0.007 0.013

    2.50 0.011 0.014 0.008 0.0102.50 -0.021 -0.001 -0.010 0.001

    1 -0.108 -0.022 -0.077 -0.015y = b/2 0 0.000 0.027 0.000 0.009

    0.013 0.023 0.006 0.010Mx My 2.00 0.015 0.016 0.010 0.0100.00 -1,169.68 -0.008 0.003 -0.002 0.003

    -233.94 -1,216.47 1 -0.086 -0.017 -0.059 -0.012-210.54 -1,076.11 0 0.000 0.025 0.000 0.007-116.97 -631.63 0.012 0.022 0.005 0.008

    0.00 0.00 1.75 0.016 0.016 0.010 0.009 -0.002 0.005 0.001 0.0041 -0.074 -0.015 -0.050 -0.010

    (01) 0 0.000 0.021 0.000 0.005 0.008 0.020 0.004 0.007

    1.50 0.016 0.016 0.010 0.008 0.003 0.006 0.003 0.0041 -0.060 -0.012 -0.041 -0.008

    0 0.000 0.015 0.000 0.003(02) 0.005 0.015 0.002 0.005

    1.25 0.014 0.015 0.008 0.007 0.006 0.007 0.005 0.0051 -0.047 -0.009 -0.031 -0.0060 0.000 0.009 0.000 0.002

    Kg/cm2. 0.002 0.011 0.000 0.0031.00 0.009 0.013 0.005 0.005

    0.008 0.008 0.005 0.0041 -0.035 -0.007 -0.022 -0.0050 0.000 0.004 0.000 0.001 0.001 0.008 0.000 0.002

    0.75 0.005 0.010 0.002 0.003 0.007 0.007 0.003 0.0031 -0.024 -0.005 -0.015 -0.0030 0.000 0.001 0.000 0.000 0.000 0.005 0.000 0.001

    0.50 0.002 0.006 0.001 0.001 0.004 0.006 0.001 0.0011 -0.015 -0.003 -0.008 -0.002

  • 7/28/2019 CALCULO RESERVORIO 80

    9/35

    (03)

    (04)

    N DOS DIRECCIONES 1:1

    (05)

    = 480.00 kg/m2= 150.00 kg/m2= 630.00 kg/m2

    = 1,258.80 kg-m.

    (06)

    (07)

    (08)

  • 7/28/2019 CALCULO RESERVORIO 80

    10/35

    = 0.13 m.

    CONFORME

    2,860.00 kg/m2.600.00 kg/m2.

    3,460.00 kg/m2.

    RNA, SE PRODUCEN

    -921.27 kg-m.

    460.64 kg-m.

    MAXIMO MOMENTO ABSOLUTO:

    (11)

  • 7/28/2019 CALCULO RESERVORIO 80

    11/35

    KG/CM2.

    cm.

    cm. CONFORME

    cm.

    cm.

    (12)

    DE LOS ESFUERZOS DEOS ESFUERZOS DE TENSION.

    endado en las Normas Sanitarias - ACI-350

  • 7/28/2019 CALCULO RESERVORIO 80

    12/35

    LOSADE

    FONDO

    -921.27

    21.00

    900.00

    9.00

    79.00

    0.441

    0.853

    -5.72

    0.0018

    100

    25

    4.5

    6.45

    5.4

    1/2"

    0.13

  • 7/28/2019 CALCULO RESERVORIO 80

    13/35

    (13)

    kg.

    (14)

    kg/cm2.

    DE:

    (15)

    kg/cm2.

    CONFORME

    kg/cm2.

    cm.

    kg/cm2.

    kg/cm2.

    kg/cm2.

    CONFORME

  • 7/28/2019 CALCULO RESERVORIO 80

    14/35

    Kg/m2.m.

    Kg/m2.

    cm.cm.

    Kg/m2.

    Kg/m2.

    CONFORME

    REDONDEAR 40

    kg/cm2.

    cm.

    kg/cm2.

    kg/cm2.

    kg/cm2.

    CONFORME

  • 7/28/2019 CALCULO RESERVORIO 80

    15/35

    ENTES (K) PARA EL CALCULO DE MOMENTOS - TAPA LIB

    y = b/2

    Mx My0.000 -0.082-0.014 -0.071-0.011 -0.055-0.006 -0.0280.000 0.0000.000 -0.074-0.013 -0.066-0.011 -0.053-0.005 -0.0270.000 0.0000.000 -0.060

    -0.012 -0.059-0.010 -0.049-0.005 -0.0270.000 0.0000.000 -0.050-0.010 -0.052-0.009 -0.046-0.005 -0.0270.000 0.000

    0.000 -0.040-0.009 -0.044-0.008 -0.042-0.005 -0.0260.000 0.000

    0.000 -0.029-0.007 -0.034-0.007 -0.037-0.005 -0.0240.000 0.0000.000 -0.018-0.005 -0.023-0.006 -0.029-0.004 -0.0200.000 0.0000.000 -0.007-0.002 -0.011

    -0.003 -0.017-0.003 -0.0130.000 0.0000.000 -0.002-0.001 -0.004-0.002 -0.009-0.001 -0.0070.000 0.000

  • 7/28/2019 CALCULO RESERVORIO 80

    16/35

  • 7/28/2019 CALCULO RESERVORIO 80

    17/35

  • 7/28/2019 CALCULO RESERVORIO 80

    18/35

  • 7/28/2019 CALCULO RESERVORIO 80

    19/35

  • 7/28/2019 CALCULO RESERVORIO 80

    20/35

  • 7/28/2019 CALCULO RESERVORIO 80

    21/35

  • 7/28/2019 CALCULO RESERVORIO 80

    22/35

    E Y FONDO EMPOTRADO

  • 7/28/2019 CALCULO RESERVORIO 80

    23/35

    DATOS :

    VOLUMEN (V) = 80.42 m3.ANCHO DE LA PARED (b) = 6.40 m.ALTURA DEL AGUA (h) = 2.50 m.BORDE LIBRE (B.L.) = 0.30 m.ALTURA TOTAL (H) = 2.80 m.PESO ESPECIFICO DEL AGUA (a) = 1,000.00 Kg/m3.PESO ESPECIFICO DEL TERRENO (t) = 1,800.00 Kg/m3.CAPACIDAD DE CARGA DEL TERRENO (t) = 1.00 Kg/cm2.PESO ESPECIFICO DEL CONCRETO (c) = 2,400.00 Kg/m3.

    A) CALCULO DE MOMENTOS Y ESPESORES

    Los lmites de relacin de b/h son de 0.5 a 3.0b/h = 2.56

    y = 0 y = b/4 y = b/2b/h x/h

    Mx My Mx My Mx My0 0.000 390.63 0.00 109.38 0.00 -781.25 187.500 343.75 78.13 125.00 -156.25 -812.50

    2.56 250.000 250.00 156.25 140.63 -140.63 -718.75 -31.250 78.13 15.63 62.50 -78.13 -421.881 -1,156.250 -234.38 -781.25 -156.25 0.00 0.00

    M = k x a x h3 (01)

    DEL CUADRO: Mx = 1,156.250 Kg-m.

    CALCULO DEL ESPESOR DE LA PARED:

    e = 6M (02)

    ft x b

    DONDE :ft = 0.85(F'c)^ = 11.24 Kg/cm2.F'c = 175.00 Kg/cm2.Mx = 1,156.25 Kg-m.My = 781.25 Kg-m.b = 100.00 cm.

    REMPLAZANDO VALORES EN (02) TENEMOS:

    e = 24.84 cm.

    PARA EL DISE O SE ASUME, QUE:e = 25.00 cm.

    CALCULO DEL ESPESOR DE LA LOSA DE CUBIERTA

    SE CALCULA COMO LOSA ARMADA EN DOS DIRECCIONES

    Espesor e = L/36 (03)

    L = b + ((2*e)/2) (04)

    REMPLAZANDO VALORES EN (04):L = 6.65 m.

    LUEGO EN 03:Espesor e = 0.18 m.

    ASUMIENDO PARA EL PROYECTO

    Espesor e = 0.15 m.

    DISEO DE RESERVORIO DE 80.00 M3.

  • 7/28/2019 CALCULO RESERVORIO 80

    24/35

    SEG N EL REGLAMENTO NACIONAL DE CONSTRUCCIONES, PARA LOSAS MACIZAS EN DOS DIRECCIONES

    MA = MB = CW(L^2) (05)

    DONDE: C = 0.036PESO PROPIO = 0,10 x 2400 = 360.00 kg/m

    CARGA VIVA = 150.00 kg/mPESO TOTAL = Wtotal = 510.00 kg/m

    REEMPLAZANDO EN LA ECUACION 05:

    MA = MB = 811.93 kg-m

    CALCULO DEL PERALTE:

    d = M (06)Rb

    SIENDO:M = MA = MB = 811.93 kg-m.b = 100.00 cm.

    R = * fc * j * k (07)

    n = 10.17k = 0.365

    j = 1 - k/3 (08)

    (1)n = (1)n = Es/Ec = (2.1 x 10^6)/(W^1.5 * Fy * (f'c)^)

    PARA W = 2.40 Tn/m3. Tn/m3.f'c = 175.00 kg/cm2. kg/cm2.Fy = 4,200.00 kg/cm2. kg/cm2.

    (2)k = 1/(1+fs/(nf'c))

    PARA fs = 1,400.00 kg/cm2.fc = 79.00 kg/cm2.

    EN LA ECUACION 08:j = 0.878

    EN LA ECUACION 09:R = 12.65

    REEMPLAZANDO VALORES EN 06:

    d = 8.01 cm.

    EL ESPESOR TOTAL (e), CONSIDERANDO UN RECUBRIMIENTO DE 2.5 CM.

    Recubrimiento ( r ) = 2.50 cm.

    e total = d + r e total = 10.51 cm. = 0.11 m.

    SIENDO: 0.11 < 0.15 m. CONFORME

    PARA EL DISE O SE CONSIDERA:

    d = 12.50 cm.

    CALCULO DEL ESPESOR DE LA LOSA DE FONDO

    ASUMIENDO EL ESPESOR DE LA LOSA DE FONDO Y CONOCIDA LA ALTURA

    e' = 0.15 m.

    h = 2.50 m.

    PESO PROPIO DEL AGUA (h x a) = 2,500.00 kg/m2.

  • 7/28/2019 CALCULO RESERVORIO 80

    25/35

    DEBIDO A LA ACCION DE LAS CARGAS VERTICALES ACTUANTES PARA UNA LUZ INTERNA, SE PRODUCENSE PRODUCEN LOS SIGUIENTES MOMENTOS:

    MOMENTO DE EMPOTRAMIENTO EN LOS EXTREMOS:

    M = -(W x L^2 /192) (09) M = -610.13 kg-m.

    MOMENTO EN EL CENTRO:M = W x L^2 /384 (10) M = 305.07 kg-m.

    CHEQUEO DEL ESPESOR DE LA LOSA:

    EL ESPESOR SE CHEQUEA POR MEDIO DEL METODO ELASTICO, CONSIDERANDO EL MAXIMO MOMENTO A

    e = 6M ft x b (11)

    ft = 0.85(F'c)^ = 12.32 KG/CM2.F'c = 210.00 KG/CM2.M = 610.13 KG-M

    b = 140.00 CM

    REMPLAZANDO EN LA ECUACION 11:e = 14.57 cm.

    14.57 < 15.00 cm. CONFORME

    POR LO TANTO CONSIDERANDO EL RECUBRIMIENTO:

    r = 4.00 cm.PERALTE:

    d = 11.00 cm.

    B) DISTRIBUCION DE LA ARMADURA DEL RESERVORIO

    As = M (12)fs x j x d

    DONDE:M = MOMENTO MAXIMO ABSOLUTO EN KG-M.fs = FATIGA DE TRABAJO EN KG/CM2.

    j = RELACION ENTRE LA DISTANCIA DE LA RESULTANTE DE LOS ESFUERZOS DEDE COMPRESION AL CENTRO DE LA GRAVEDAD DE LOS ESFUERZOS DE TENSIO

    d = PERALTE EFECTIVO EN CM.

    CALCULO DE LA ARMADURA DE LA PARED:

    M+ = 1,156.25 kg-m.

    M- = 812.50 kg-m.fs = 900.00 kg/cm2.n = 9.00 Valores recomendado en las Normas Sanitariase = 25.00 cm.r = 12.50 cm.d efectivo = 7.50

    j = 0.85k = 0.441b = 100.00 cm.

    R = * fs * j * k

    n = 10.50k = 0.48

    j = 1 - k/3

    (1)n = (1)n = Es/Ec = (2.1 x 10^6)/(W^1.5 * Fy * (f'c)^)

  • 7/28/2019 CALCULO RESERVORIO 80

    26/35

    (2)k = 1/(1+fs/(nf'c))

    PARA fs = 900.00 kg/cm2.f'c = 79.00 kg/cm2.

    EN LA ECUACION 08:

    j = 0.84EN LA ECUACION 09:R = 18.13

    REEMPLAZANDO VALORES EN 06:

    d = 0.80 cm.

  • 7/28/2019 CALCULO RESERVORIO 80

    27/35

    RESUMEN DEL CALCULO DEL ACERO(RESERVORIO DE 80.00 M3.)

    PARED LOSA LOSADESCRIPCION DE DE

    VERTICAL ORIZONTAL CUBIERTA FONDOMomento "M" (kg - m) 1,156.25 781.25 811.93 -610.13Espesor Util "d" (cm.) 12.50 12.50 12.50 11.00fs (kg/cm2.) 900.00 900.00 1,400.00 900.00n 9.00 9.00 10.00 9.00f'c (kg/cm2.) 79.00 79.00 79.00 79.00k = 1/(1+ fs / (n x f'c)) 0.441 0.441 0.361 0.441j = 1 - (k/3) 0.853 0.853 0.880 0.853Area de AceroAs = (100 x M)/(fs x j x d) (cm2.) 12.05 8.14 5.27 -7.23C 0.0018 0.0018 0.0018 0.0018b (cm.) 100 100 100 100e (cm.) 25 25 15 15Cuantia MnimaAsmn = C x b x e (cm2.) 4.5 4.5 2.7 2.7Area Efectiva de As2. (cm2.) 14 9.03 2.84 4.26

    Area Efectiva de Asmn2. (cm2.) 4.97 4.97 4.97 4.97 de Acero 5/8" 1/2" 3/8" 3/8"Distribucin 3/8"(Aacero/Aacero total) 0.14 0.14 0.14 0.14

    C) CHEQUEO POR ESFUERZO CORTANTE Y ADHERENCIA

    CHEQUEO DE LA PARED

    1. - ESFUERZO CORTANTE MAXIMA (V), SERA:

    V = (a x h^2) /2 (13)

    REEMPLAZANDO VALORES EN LA ECUACION 13:

    V = 3,125.00 kg.

    ESFUERZO CORTANTE NOMINAL

    v = V/(j x b x d) (14)

    DATOS J = 7/8 = 0.875

    POR LO TANTO:v = 2.86 kg/cm2.

    EL ESFUERZO PERMISIBLE NOMINAL EN EL CONCRETO PARA MUROS NO EXCEDERA DE:

    Vmx = 0,02 * f'c (15)

    Para f'c = 175.00 kg/cm2.

    Vmx = 3.50 kg/cm2.

    2.86 < 3.50 CONFORME

    2.- CHEQUEO POR ADHERENCIA

    ESFUERZO DE ADHERENCIAu = V /(o * J * d)

    SIENDO: o para 5,8 14.29o para 5,8 14.00 cm. = 100.57

    V = 3,125.00 kg/cm2.j = 0.85d = 12.50 cm.

    u = 2.92 kg/cm2.

    ESFUERZO PERMISIBLE POR ADHERENCIA

  • 7/28/2019 CALCULO RESERVORIO 80

    28/35

    f'c = 175.00 kg/cm2.

    umx = 8.75 kg/cm2.

    2.92 < 8.75 CONFORME

    CHEQUEO DE LA LOSA DE CUBIERTA

    1. - ESFUERZO CORTANTE MAXIMA (V), SERA:

    V = W * S /3

    W = 510.00 Kg/m2.S = b = 6.40 m.

    RemplazandoV = 1088.00 Kg/m2.

    2. - CORTANTE UNITARIO (v), SERA:

    v = V / b*d

    b = 100.00 cm.d = 12.50 cm.

    v = 0.87 Kg/m2.

    3. - ESFUERZO CORTANTE MAXIMA UNITARIO (vmx), SERA:

    vmx = 0,29 * (f'c^(1/2))

    vmx = 3.84 Kg/m2.

    0.87 < 3.84 CONFORME

    12.072.- CHEQUEO POR ADHERENCIA

    ESFUERZO DE ADHERENCIAu = V /(o * J * d)

    SIENDO: o para 3/8 14.2914.00 cm. = 35.70 REDONDEA 26

    V = 6.40 kg/cm2.j = 0.879d = 7.50 cm.

    u = 6.35 kg/cm2.

    ESFUERZO PERMISIBLE POR ADHERENCIA

    umx = 0,05 * f'c

    f'c = 175.00 kg/cm2.

    umx = 8.75 kg/cm2.

    6.35 < 8.75 CONFORME

  • 7/28/2019 CALCULO RESERVORIO 80

    29/35

    VALORES DE LOS COEFICIENTES (K) PARA EL CALCULO DE MOMENTOS - TAP

    y = 0 y = b/4 y = b/2b/h x/h

    Mx My Mx My Mx My0 0.000 0.025 0.000 0.014 0.000 -0.082 0.010 0.019 0.007 0.013 -0.014 -0.071

    3.00 0.005 0.010 0.008 0.010 -0.011 -0.055 -0.033 -0.004 -0.018 0.000 -0.006 -0.0281 -0.126 -0.025 -0.092 -0.018 0.000 0.0000 0.000 0.027 0.000 0.013 0.000 -0.074 0.012 0.022 0.007 0.013 -0.013 -0.066

    2.50 0.011 0.014 0.008 0.010 -0.011 -0.053 -0.021 -0.001 -0.010 0.001 -0.005 -0.0271 -0.108 -0.022 -0.077 -0.015 0.000 0.0000 0.000 0.027 0.000 0.009 0.000 -0.060 0.013 0.023 0.006 0.010 -0.012 -0.059

    2.00 0.015 0.016 0.010 0.010 -0.010 -0.049

    -0.008 0.003 -0.002 0.003 -0.005 -0.0271 -0.086 -0.017 -0.059 -0.012 0.000 0.0000 0.000 0.025 0.000 0.007 0.000 -0.050 0.012 0.022 0.005 0.008 -0.010 -0.052

    1.75 0.016 0.016 0.010 0.009 -0.009 -0.046 -0.002 0.005 0.001 0.004 -0.005 -0.0271 -0.074 -0.015 -0.050 -0.010 0.000 0.0000 0.000 0.021 0.000 0.005 0.000 -0.040 0.008 0.020 0.004 0.007 -0.009 -0.044

    1.50 0.016 0.016 0.010 0.008 -0.008 -0.042 0.003 0.006 0.003 0.004 -0.005 -0.0261 -0.060 -0.012 -0.041 -0.008 0.000 0.000

    0 0.000 0.015 0.000 0.003 0.000 -0.029 0.005 0.015 0.002 0.005 -0.007 -0.034

    1.25 0.014 0.015 0.008 0.007 -0.007 -0.037

    0.006 0.007 0.005 0.005 -0.005 -0.0241 -0.047 -0.009 -0.031 -0.006 0.000 0.0000 0.000 0.009 0.000 0.002 0.000 -0.018 0.002 0.011 0.000 0.003 -0.005 -0.023

    1.00 0.009 0.013 0.005 0.005 -0.006 -0.029 0.008 0.008 0.005 0.004 -0.004 -0.0201 -0.035 -0.007 -0.022 -0.005 0.000 0.0000 0.000 0.004 0.000 0.001 0.000 -0.007 0.001 0.008 0.000 0.002 -0.002 -0.011

    0.75 0.005 0.010 0.002 0.003 -0.003 -0.017 0.007 0.007 0.003 0.003 -0.003 -0.0131 -0.024 -0.005 -0.015 -0.003 0.000 0.0000 0.000 0.001 0.000 0.000 0.000 -0.002 0.000 0.005 0.000 0.001 -0.001 -0.004

    0.50 0.002 0.006 0.001 0.001 -0.002 -0.009 0.004 0.006 0.001 0.001 -0.001 -0.007

    1 -0.015 -0.003 -0.008 -0.002 0.000 0.000

  • 7/28/2019 CALCULO RESERVORIO 80

    30/35

  • 7/28/2019 CALCULO RESERVORIO 80

    31/35

    O:

    0

  • 7/28/2019 CALCULO RESERVORIO 80

    32/35

  • 7/28/2019 CALCULO RESERVORIO 80

    33/35

  • 7/28/2019 CALCULO RESERVORIO 80

    34/35

  • 7/28/2019 CALCULO RESERVORIO 80

    35/35

    LIBRE Y FONDO EMPOTRADO