Cablingnetrfp Guidelines

12
Request For Proposal for A EXPANSION of the LAN and WAN Network o f Pelican Life Sciences Huntersville , NC Integrating additional subsidiaries into the Pelican VPN network RFP: 07309.1 Closing Date and Time: 5:00 pm Thursday, December 6, 2007 Description: This RFP covers the engineering, procurement, and installation of a Local Area Network (LAN) System with Internet and Wide Area Network connections at the Huntersville, North Carolina headquarters of Pelican Life Sciences. A smaller network will be provided for the company’s financial department in Portsmouth, New Hampshire. Internet and Virtual Private Network connections will be provided between two offices and four other remote locations. Pelican Life Sciences, Inc. or Pelican Holdings is a new corporation servicing the BioSciences technology field. It has targeted a number of firms for acquisition to merge them into one large leader in the biosciences or life sciences field. It has acquired four firms, to date with locations show on the Visio Map included with this RFP. Each of the newly acquired firms has an existing network that will need to be integrated to the new network via use of a Virtual Private Network (VPN) with T1 circuits into the Internet. The Headquarters is in a new building, which is not built-out to Pelican’s specifications as yet. Design criteria: The successful proposal will include designs for a switched Gigabit Ethernet LAN for the Headquarters, and a smaller LAN for the Finance Department in Portsmouth, NH. Firewall/router/VPN concentrator devices will be installed as part of this proposal at the Headquarters, the New Hampshire office, and

Transcript of Cablingnetrfp Guidelines

Request For Proposal for

A EXPANSION of the LAN and WAN Network

of

Pelican Life Sciences

Huntersville, NC

Integrating additional subsidiaries into the Pelican VPN network

RFP: 07309.1

Closing Date and Time: 5:00 pm Thursday, December 6, 2007

Description: This RFP covers the engineering, procurement, and installation of a Local Area Network (LAN) System with Internet and Wide Area Network connections at the Huntersville, North Carolina headquarters of Pelican Life Sciences. A smaller network will be provided for the companys financial department in Portsmouth, New Hampshire. Internet and Virtual Private Network connections will be provided between two offices and four other remote locations.

Pelican Life Sciences, Inc. or Pelican Holdings is a new corporation servicing the BioSciences technology field. It has targeted a number of firms for acquisition to merge them into one large leader in the biosciences or life sciences field. It has acquired four firms, to date with locations show on the Visio Map included with this RFP.

Each of the newly acquired firms has an existing network that will need to be integrated to the new network via use of a Virtual Private Network (VPN) with T1 circuits into the Internet.

The Headquarters is in a new building, which is not built-out to Pelicans specifications as yet.

Design criteria: The successful proposal will include designs for a switched Gigabit Ethernet LAN for the Headquarters, and a smaller LAN for the Finance Department in Portsmouth, NH. Firewall/router/VPN concentrator devices will be installed as part of

this proposal at the Headquarters, the New Hampshire office, and four additional remote locations across the United States. The remote locations are in Pittsburgh PA, Portland OR, Naperville IL, and San Diego CA (see Visio map).

The headquarters network will utilize MS Windows 2003 Server Enterprise Edition for its network operating system. It must be capable of storage of a large number of files from Microsoft Office programs such as Word, Excel, PowerPoint, Outlook, as well as large SQL databases and the files of Hyperion data mining software.

The LAN with its WAN/VPN connection will be capable of supporting high-speed transfer of files, email and multimedia materials. It will utilize a complete installation of Microsoft Exchange e-Mail software. A WEB Server will be located in the DMZ on the Hdqrs system.

Approximately 10 Microsoft WinXP Professional clients will be supported via a standard

TIA 569 premises wiring scheme using Category 6 Unshielded Twisted Pair (UTP)

cabling. The location of the 110 data outlets will be as shown on the floor plan for the headquarters. Four (4) laptops (with docking stations) and two (2) desktop systems in the Hdqrs will be supplied as part of this proposal and will be the latest Intel based systems with >30 Gigabyte hard disks.

All visitors to the headquarters will be able connect their laptops to the Internet via a

802.11a/g/b router at the headquarters. For security, reasons this router will be in the DMZ and normally no access will be provided to the LAN for these users. For visiting Pelican executives, access to the LAN will be via the Cat 6 wiring infrastructure.

The center is to be connected to the Internet via a T1 circuit. A T-1 circuit for WAN/Internet use must be supplied in the successful proposal with appropriate routers and communications equipment as required.

In addition to the specified Category (Cat) 6 data connections cable, each outlet will

also include a Cat 5 telephone connection. All outlets will have one RJ-45 data jack and one RJ-25 (three pair) telephone jack. The telephone lines will terminate on the telco rack in the equipment room. All fire and building codes must be observed in proposal and installation.All systems have been bought with Gigabit Ethernet Network Interface cards. This is to be shown as part of the wiring diagram required on the next page.

All LAN switches are to be supplied with management modules. This class of equipment should be supplied from one of the following approved manufacturers (as listed on the approved manufactures pages at the end of this document. All LAN switches will be from the same manufacturer. The wireless access router can be of Linksys or equal quality, this is only an accommodation for visitors.

Sufficient industrial/commercial Network servers are to be provided to support the following services on the LAN/WAN: File serving, and Print serving. Each executive office will have an small inkjet printer and a large central network color printer, scanner, fax machine will be available to all systems in the office. Pelican will make very active use of Microsoft Exchange electronic mail with all of its new acquisitioned companies and the life science industry. For this reason storage capability should be adjusted accordingly. Likewise, an Intranet will be utilized for easy document/form and information retrieval. A group of client-server applications (such Oracle) will be run as processes at the servers. All secondary storage on servers will utilize SCSI Raid Arrays. This class of equipment should be supplied from one of the following approved manufacturers: Compaq, Dell, or IBM.

One T1 interface unit/multiplexer (CSU/DSU) is to be supplied and the installation of the T1 circuit is to be arrange with ALLTEL. A corporate size WAN router is to be provided and it does not have to be from the same source as the LAN switches/hubs. This class of equipment should be supplied from the following approved manufacturers listed.

Headquarter Office Suite : A plan of the building is included as attachment 2. The suite consists of part of the first floor of a building. All Offices walls will be of standard

1 plasterboard over metal studs (with insulation for sound proofing-firebreak cross

members are include in walls). The ceiling of the suite will be a dropped ceiling plenum air-return system. No wiring troughs (cable trays) are currently installed in the building. Due to the small size of the LAN and office, no troughs will be required. Instead all cabling must be neatly supported on the walls above the drop ceiling. All cabling will be fished though the walls. No systems in the building require extraordinary EMI-RFI shielding.

Submission and evaluation of proposals: The proposals are to be submitted in the form specified in the instructions at attachment 1. Bids will be opened at 5:00 PM on

the closing date. The proposals will be evaluated after the second week of April and the selection of the successful proposal will be announced by May 2, 2006. The proposal will not be evaluated on cost solely. Pelican Life Sciences reserves the right to accept one of the proposals, determined to fits its needs, or to reject all proposals.

Authorized Equipment ManufacturersComputers: Dell Compaq IBM

Switches: (Must be manageable, not cheapest units) Nortel

3Com Cisco Dell Compaq

VPN Concentrators, Firewalls, routers

WatchGuard Cisco Barracuda

Racks

Telco: Anything with full wire management

Server Enclosure: Same brand as Servers

Instructions For Firms Submitting Proposals (BIDS)for

A LAN and WAN Network

For

Pelican Life Sciences

Headquarters, Huntersville, NC

With Wan Connections for 5 Other Locations

RFP: 070309.1Closing Date and Time: 5:00 pm Thursday, December 6, 2007

1. You are to submit a formal professional Technical Design and Cost Proposal (bid)

for this LAN/WAN by the closing date and time (as indicated above).

2. Your proposal should be responsive to the criteria stated in the basic proposal and as clarified by both written and verbal communications from the procurement officer to all bidders. The organization of the bid is to be strictly followed or the bid will be disqualified.a. Qualifications Statement: (2 Pages minimum)

1. Submit evidence of professional qualifications and experience in the networking field

2. List of your LANs and WANs installed and or maintained by your firm.

3. Provide a list of references with addresses and telephone numbers. Include a statement of the work done for each of the references.

b. Executive Narrative: A statement of the design of your proposed LAN (1

page minimum). This narrative should be clear enough for our presentation to non-IT corporate officers, such as the Chairperson of the Board, the President and Vice-President of Financial Affairs. It should also have enough detail to satisfy the IT Managers review.

c. Diagrams of Proposed Installation:1. Wiring Plan for the headquarters office suite (Visio drawings of the suite are provided in RFP kit) (2 pages minimum)

2. Equipment Room and its Racks in each room (Use equipment room

Visio drawing (3 page minimum)

3. VPN (WAN) View / Map

d. Bill of Materials: - Show components of network and proposed cost to us in high detail. Include all materials provided!An Excel Spreadsheet format is provided in RFP kit as sample of submittal document. Some of the Items requiring listings are:

Switches

Servers

Printers (postscript laser) & network printer interfaces TIA 569 patch panels, wire and wiring terminations Rack

Power supplies

Network interface Cards for all machines

Modems

Router/Firewall/VPN concentrator appliance(s) T1 interface unit, CSU/DSUs

Cat 5e and Cat 6 Cable

Patch cable

Patch PanelsCat 5e & 6 wall sockets, faceplateAnd other items needed.

e. Labor Cost Listing: Installation labor costs for Headquarters LAN/WAN and separate costs for the installation of the router/firewall/VPN devices at the five other remote locations. (1 page or more as needed ) List labor and travel costs to remote locations separately

f.Timeline: Give schedule of installation with completion date of Jun 30, 2006 g. Listing: Installation manning plan with names, positions and approximate

time allocated to project.

h. SUMMARY COST DATA: The bottom line. (1 page limit) Page must give listing of:

1.Total Cost of all equipment and software with the capacity provided.

2.Total Cost of labor for installation

3.Total Cost of all material and all labor.

4.Average Cost per system of providing LAN and Internet connection

3. Scoring of the proposals submitted will be done in accordance with the Sample

Scoring Sheets (Attached)

SAMPLE SCORING SHEETNETWORK DESIGN and INSTALLATION PROJECTRFP: 07309.1Closing Date and Time: 5:00 pm Thursday, December 6, 2007NAME

TOTAL POINTS

1. Technical Appropriateness of Design and Cost: (30)2. Completeness & Accuracy of Bill of Materials (30)3. Quality and completeness of Diagrams (20)a. Hdqrs LAN schematicb. Headquarters Wiring Plan:c. Hdqrs Equipment Room and Rack Diagrams d. WAP coveragee. Typical remote location schematic f.WAN network schematic (Map)4.. Overall Professional Appearance and quality of narrative (20):SAMPLE SCORING SHEETNETWORK DESIGN and INSTALLATION PROJECTRFP: 07309.1Required Document and Order of Insertion for evaluating ofCompleteness and grading

a. Qualifications Statement: (1-2 Pages minimum)

1. Submit evidence of professional qualifications and experience in the networking field

2. List of your LANs/WANs installed and or maintained byyour firm.

3. Provide a list of references

b. Executive Narrative: statement of the design of your proposedLAN (1 page minimum).

c. Diagrams of Proposed Installation:

1. Wiring Plan for Headquarters building Huntersville, NC.

2. Printer location plan

3. Equipment Rack of Patch Panel, Switch, router, server(Use drawing above) (1 page minimum)

d. Bill of Materials: - Show components of network and proposedcost to us. (1 page minimum)

1. Switches

2. Servers

3. Printers & network printer interfaces

4. TIA 569 patch panels, wire and wiring terminations

5. Enclosed Rack for office

6. Power supplies

7. Network interface Cards for all machines

8. Router/Firewall/VPN concentrators or appliance

e. Listing: Hdqs Installation labor Costs (1 page or more as needed)

f. Listing: Installation of Portsmouth and other remote locations. Breakout labor and travel expenses.

g. Timeline: Give schedule of installation with starting date

h. Listing: Installation manning plan with names, positions andapproximate time allocated to project.

i. SUMMARY COST DATA: The bottom line. (1 page limit) Pagemust give listing of:

1. Total Cost of all equipment and software with thecapacity provided.

2. Total Cost of labor for installation at all locations

3. Total Cost of Everything Materials, Labor