Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend...

16
Nationwide Industries 10333 Windhorst Rd. Tampa, FL 33619 813.988.2628 Fax: 813.988.3465 Photo courtesy of FabWorx Cable Railing Kit Application Guide January 2019

Transcript of Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend...

Page 1: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

Nationwide Industries10333 Windhorst Rd.

Tampa, FL 33619813.988.2628

Fax: 813.988.3465

Photo courtesy of FabWorx

Cable Railing Kit Application

GuideJanuary 2019

Page 2: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

813.988.2628 | www.nationwideindustries.com2

Framework You Will Need for Cable RailingEnd Post ConstructionSince over 200 pounds of tension is being applied to end posts using cable railing, those posts must be substantial enough to handle that tension.

Wood PostsFor wood posts a minimum 4x4 (3½”-square) post is required to keep the post from bending when the cables are tensioned. You will need a top rail, and we recommend that it be reinforced with a support such as a 2x4 on end under the top rail. End posts must be securely mounted to the deck to prevent the post from coming loose when the cables are tensioned. A bottom rail helps distribute the force away from the bottom of the post, but is not required.

Metal PostsFor steel posts, kits are designed for use with 1½”x1½” square and 2”x2” square tube. End posts will need to be a minimum 1/4” wall to handle the load when the cables are tensioned; intermediates can be 1/8”. As with wood posts, you will need a top rail, but that is sufficient for structural integrity. For aluminum, your end posts should be reinforced and you may want to consider a bottom rail to help prevent post-bowing.

Of course, secure mounting of the posts to the deck is just as important with metal posts as wood, and as important with end posts as intermediates.

Intermediate posts between end and corner postsTo keep the cable from spreading beyond IBC code requirements, we recommend that the cable be supported in some manner no more than every 48” along its run. Intermediate posts, through which the cable is strung, act as supports for the cable. To avoid having to use more intermediate posts than is structurally necessary, a thin metal cable brace with holes for the cables to pass through can be used to support the cables (see illustrations). A typical cable brace is either 3/4” x 3/4” aluminum tube or 1/4” thick by 1” wide stainless steel flat bar and is ordered separately.

Cable spacing on your postsWe recommend that you space the cables with no more than a 3” clear span between the cables (see illustrations). For example, if you are using 1/8” diameter cable, you would drill your holes on center no more than 3-1/8” apart.

Frame must support enough tension to keep cables taut (will vary with wood used).

3" clear opening between cables.

(Railing not to scale)

Max. 48" Max. 48" Max. 48" Max. 48"

Support posts nomore than every 48".

(Railing not to scale)(Ra(Ra(Ra(R(Ra(Ra(Ra(RaRaaililiilililiililiiliililinnggngngngng ng ng ng g notnotnotnotnotnotn tnnotonotno totototototot scsccscscs alealelalealeale)))

Max. 48" Max. 48" Max. 48" Max. 48"

(Railing not to scale)

Frame must support minimum of 225 lbs. tension per cable.

3" clear opening between cables.

Support posts nomore than every 48".

Page 3: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

www.nationwideindustries.com | 813.988.2628 3

Decks come in all shapes and sizes, but there are only a few types of cable runs that go on those decks: face-mounted and through-the-post. The following illustrations represent several ways you can run cable on your deck. Every run will require a fitting that will act to tension the cable once installed. Depending on the length of the run, the tensioning device in the kit, and whether you plan to bend the cable through a corner, you will either

Your Deck Typebe able to use a non-tensioning Push-Lock® or Pull-Lock® on the other end or you will need to use a Push-Lock® tensioner on the other end.The VIP RunYou will see that Run #1 on each drawing is the “view run” — the one that is most important, most visible of all your runs. It’s the one on which you want to have the least interference with the view, so you always start with that run and build around it.

Page 4: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

813.988.2628 | www.nationwideindustries.com4

Cable Railing Kits

For straight runs:102 Series (both ends through-the-post)

Threaded stud to Pull-Lock®.262 Series (both ends through-the-post)

3½” Invisiware® Receiver to Pull-Lock®.300 Series (both ends face-mounted)

Adjust-a-Body® with Hanger Bolt to Push-Lock® Lag.

For straight runs:102 Series (both ends through-the-post)

Threaded stud to Pull-Lock®.212 Series for 1½” posts232 Series for 2” posts224 Series for 2-3/8” posts

(both ends through-the-post) Post-dimension Invisiware® Receiver to same-length Pull-Lock®.

401 Series (both ends face-mounted) Adjust-a-Body® with Threaded Bolt to Push-Lock® Threaded Bolt.

401 Series

102 Series

212, 232, and 224 Series

500-M Series232 and 224 Series102 Series

401 Series

102 Series

212, 232, and 224 Series

500-M Series232 and 224 Series102 Series

Kits for wood posts Kits for metal posts

For straight runs:300-C Series (both ends face-mounted)

Adjust-a-Body® with Extended Length Hanger Bolt to Push-Lock® Lag.

Kits for wood posts with composite sleeves

300 Series

102 Series

262 Series

500-W Series262 Series with CS-Tube102 Series with CS-Tubes

300 Series

102 Series

262 Series

500-W Series262 Series with CS-Tube102 Series with CS-Tubes

232 Series with Spacers

for pitched runs in 1½” posts

For stairs, pitched runs:102 Series (both ends through-the-post)

Threaded Stud to Pull-Lock®. 232 and 224 Series (both ends through-the-post)

Invisiware® Receiver to Pull-Lock®. 500-M Series (both ends face-mounted)

Push-Lock® with Threaded Eye to Adjust-a-Body® with Threaded Eye. Threaded tabs on both ends.

For stairs, pitched runs:102 Series (both ends through-the-post)

Threaded Stud to Pull-Lock®. Post Protector Tubes used on both ends.

262 Series (both ends through-the-post) Invisiware® Receiver to Pull-Lock® using a Post Protector Tube.

500-W Series (both ends face-mounted) Push-Lock® with Threaded Eye to Adjust-a-Body® with Threaded Eye. Lag eyes on both ends.

For stairs, pitched runs:500-C Series (both ends face-mounted)

Push-Lock® with Threaded Eye to Adjust-a-Body® with Threaded Eye. Extended length lag eyes on both ends.

300-C Series

500-C Series

300-C Series

500-C Series

300-C Series

500-C Series

300-C Series

500-C Series

Page 5: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

www.nationwideindustries.com | 813.988.2628 5

Through-the-Post Mount

Decks 1 and 2 have dedicated end posts for each run, and the posts are situated such that the back side of the posts are all accessible, meaning you can use a through-the-post configuration. This is both the most economical solution and where the fittings are least visible. For wood posts, use the 262 Series. The tensioning device is a 3½” long Invisiware® Receiver, which installs through the wood post on one end. A Pull-Lock® fitting is installed through the other end.

For 1-1/2” metal square tube, use the 212 Series. For 2” square tube, use the 232 Series. For 2-3/8” square tube, use the 224 Series. The tensioning device is, respectively, a 1½”, 2”, or 2-3/8” long Invisiware® Receiver, which installs flush-through the tube on one end. A same-length Pull-Lock® fitting is installed flush-through the other end.

When taking cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double corner post configuration is required as illustrated in Deck 2.

House

3½”min. 3½”min.

Ru

n #

2

Run #1

Ru

n #3

Wood Posts: Series 262 Metal Posts: Series 212/232/224

Deck 1

Straight Cable Runs and Cable Runs through One Corner

House

3½”min. 3½”min.

Wood Posts: Series 262

For post protector tubes (used with wood posts), see Tools and Essentials section.

Metal Posts: Series 224

Deck 2

262 Series

Pull-Lock® Fitting

with cap

1/8” and 3/16” 1x19 stainless

steel cable

Pre-attached swaging stud

Invisiware®

Receiver

Stainless Steel washers

Post Size: Kit: 1-1/2”: 212 Series 2”: 232 Series 2-3/8”: 224 Series

Pull-Lock® Fitting

with cap

1/8” and 3/16” 1x19 stainless

steel cable

Pre-attached swaging stud

Invisiware®

Receiver

Delrin® washers for use with metal posts

Cable Length PART NO. PART NO.

1/8” cable

5’10’15’20’25’

2” Metal Post

1½” Metal Post

2320523210232152322023225

2120521210212152122021225

PART NO.

1½” Metal Post

23205-623210-623215-623220-623225-6

3/16” cable

PART NO.

2” Metal Post

21205-621210-621215-621220-621225-6

Series 212 and 232 Kits

Cable Length PART NO. PART NO.

1/8” cable2-3/8” Metal

Post4x4 Wood

Post2-3/8” Metal

Post4x4 Wood

Post

2240522410224152242022425224302244022450

2620526210262152622026225262302624026250

PART NO.22405-622410-622415-622420-622425-622430-622440-622450-6

3/16” cable

PART NO.26205-626210-626215-626220-626225-626230-626240-626250-6

Series 262 and 224 Kits

5’10’15’20’25’30’40’50’

Tools needed for 262, 212, 232, and 224 Series:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable29/64 drill bit for Receiver® and Pull-Lock® installation3/16 hex wrench for tensioning ReceiverCable cutting tool If using post protector tubes, 1/4 drill bit

Because there is less take-up in the Receivers for the 212 and 232 series, those kits are not offered in lengths beyond 25’. Use a 224 series kit for longer runs with 1½” or 2” posts.

Wood and Metal Posts

Page 6: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

813.988.2628 | www.nationwideindustries.com6

Through-the-Post MountStraight Cable Runs and Cable Runs through One Corner

Tools needed for 102 Series:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable9/32 drill bit for threaded stud installation29/64 drill bit for Pull-Lock® installation1/8 hex wrench for holding the stud7/16 wrench for tightening jam nutsCable cutting toolIf using post protector tubes, 1/4 drill bit

House

Series 102

3½”min. 3½”min.

For post protector tubes, see Tools and Essentials section.

Deck 2

A through-the-post configuration is the only scenario in which the economical threaded stud kits may be used. The threaded stud kits are even more economical than the 200 series, but the threaded studs are a basic, functional fitting, not a hide-in-the-post solution. A brass hex nut and some metal thread (both covered by an end cap) will extend beyond the back of the post on one end. A Pull-Lock® fitting is installed through the other end.

For either wood or metal posts, use the 102 Series.The tensioning device is a 2-7/8” long threaded stud which installs on the back side of one end post, as shown in Deck 1.

When taking cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double corner post configuration is required as illustrated in Deck 2.

102 Series

Pull-Lock® Fitting

with cap

Stainless Steel washer for wood

Stainless Steel

washer for wood

Delrin® washerfor metal

Stainless Steel washer for metal

Brass locknut

1/8” 1x19 stainless steel

cable

Pre-attached threaded stud

House

Series 102

3½”min. 3½”min.

Deck 1

Wood and Metal Posts

Optional Cap for Threaded StudFinish the look of your 102 Kit cable runs with our stainless steel cap to cover the brass locknut. Order one CAP-S/S for each locknut.

Cable Length PART NO. PART NO.

1/8” cable 3/16” cable

5’10’15’20’25’30’40’50’

1020510210102151022010225102301024010250

10205-610210-610215-610220-610225-610230-610240-610250-6

Series 102 Kits

Page 7: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

www.nationwideindustries.com | 813.988.2628 7

House

Wood Posts: Series 300

Metal Posts: Series 401

For post protector tubes (used with wood posts), see Tools and Essentials section.

Deck 1 has only one end post at the corners. The posts next to the house butt right up to it so the back sides of those posts are not accessible. Run #1 is still through-the-post, so it will take a Series 262 kit (for wood posts) or a 200 Series kit (for metal posts). Runs #2 and #3 connect to the face of the corner post going back toward the house to keep the cables on the same plane. They also connect to the face of the posts next to the house as well.

For wood posts, use the 300 Series. The tensioning device is an Adjust-a-Body® with Hanger Bolt, which lags into the wood post on one end. A Push-Lock® Lag is lagged into the other end.

For metal posts, use the 401 Series. The tensioning device is an Adjust-a-Body® with Threaded Bolt, which threads into the metal post on one end. A Push-Lock® Threaded Bolt is threaded into the other end.

When taking cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double corner post configuration is required as illustrated in Deck 2.

300 Series

Push-Lock® Lag

Adjust-A-Body® with Hanger Bolt

1/8” and 3/16”1x19 stainless

steel cable

Pre-attached swaging ferrule

Face MountStraight Cable Runs and Cable Runs through One Corner

Delrin® washer

401 Series

Push-Lock® Threaded

Bolt

Adjust-A-Body® with Threaded Bolt

1/8” and 3/16” 1x19 stainless

steel cable

Pre-attached swaging ferrule

House

Ru

n #

2

Run #1

Ru

n #3

Wood Posts: Series 300 Metal Posts: Series 401

Wood Posts: Series 262 / Metal Posts: Series 212/232/224

Deck 1

Deck 2

Cable Length PART NO. PART NO.

1/8” cable

PART NO.

3/16” cable

PART NO.

Series 300 and 401 Kits

5’10’15’20’25’30’40’50’

Metal Post

4x4 WoodPost

Metal Post

4x4 WoodPost

4010540110401154012040125401304014040150

40105-640110-640115-640120-640125-640130-640140-640150-6

3000530010300153002030025300303004030050

30005-630010-630015-630020-630025-630030-630040-630050-6

Tools needed for 401 Series:

5/32 drill bit if 1/8” cable, 7/32 if 3/16” cableCutting tap drill bit I (for pilot hole) and 5/16-24 tap for threaded bolt installation7/16 wrench for tensioning Adjust-a-Body® 3/8 wrench for installing Push-Lock® Threaded BoltCable cutting tool

Tools needed for 300 Series:

5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable7/32 drill bit for hanger bolt and lag installation 5/32 hex wrench for turning hanger bolt7/16 wrench for tensioning Adjust-a-Body® 3/8 wrench for installing Push-Lock® Lag Cable cutting toolIf using post protector tubes, 1/4 drill bit

Wood and Metal Posts

Page 8: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

813.988.2628 | www.nationwideindustries.com8

Deck 1 has wood posts with composite sleeves. For sleeved posts, the recommended approach is face-mount for the best finished look. Since Deck 1 has only one end post at the corners, there is no bending of the cable through those posts. Each run must be start and stop. All three runs use the same kit.

For wood posts with composite sleeves having an outside diameter of 4-1/2” or greater, use the 300-C Series: The tensioning device is an Adjust-a-Body® with Extended Length Hanger Bolt, which lags into the wood post on one end. A Push-Lock® Lag is lagged into the other end.For wood posts with composite sleeves having an outside diameter of 4-1/2” or less, use the standard 300 Series.

300-C Series

Push-Lock® Lag

1/8” or 3/16” 1x19 stainless

steel cable

Adjust-a-Body® withExtended Length Hanger Bolt

Cable Length PART NO. PART NO.

1/8” cable 3/16” cable

5’10’15’20’25’30’40’50’

30005-C30010-C30015-C30020-C30025-C30030-C30040-C30050-C

30005-C630010-C630015-C630020-C630025-C630030-C630040-C630050-C6

Series 300-C Kits

Face MountStraight Cable Runs

House

Series 300-C

Deck 1

Tools needed for 300-C Series:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable7/32 drill bit for hanger bolt and lag installation5/32 hex wrench for turning hanger bolt 7/16 wrench for tensioning Adjust-a-Body® 3/8 wrench for installing Push-Lock® LagCable cutting tool

Wood Posts with Composite Sleeves

Page 9: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

www.nationwideindustries.com | 813.988.2628 9

Cable Runs on a Pitch

Series 262

Series 102

Through-the-Post Mount Wood Posts

The cleanest approach to running cable on a pitch is to drill through both end both posts on the square (NOT at the angle of the stairs). No beveled washers necessary. Only intermediate posts need to be drilled on the angle of the stairs.

For wood posts, use the 262 Series. The tensioning device is a 3½” long Invisiware®

Receiver, which installs through the wood post on one end. A Pull-Lock® fitting is installed through the other end with a post protector tube (CS-TUBE), ordered separately. The 262 Series can be used to go up a stair and across a landing by inserting post protector tubes in the break-over post. The tube will prevent the cable from carving a groove into your post where it exits at an angle.

Post Protector Tube

Pull-Lock® with SAE washer

Invisiware® Receiver with SAE washer

Tools needed for 262 Series:5/32 drill bit if 1/8” cable, 7/32 if 3/16”cable29/64 drill bit for Receiver and Pull-Lock® installation3/16 hex wrench for tensioning ReceiverCable cutting tool If using post protector tubes, 1/4 drill bit

For post protector tubes (used with wood posts), see Tools and Essentials section.

For post protector tubes (used with wood posts), see Tools and Essentials section.

Pull-Lock® with SAE washerand post protector tube

Threaded Stud with washerand post protector tube

t protector tube

Threaded Stud with wd t t t td t t t t

Cable Length PART NO. PART NO.

1/8” cable 3/16” cableSeries 262 Kits

5’10’15’20’25’30’40’50’

2620526210262152622026225262302624026250

26205-626210-626215-626220-626225-626230-626240-626250-6

102 Series

Pull-Lock® Fitting

with cap

Stainless Steel washer for wood

Stainless Steel

washer for wood

Delrin® washerfor metal

Stainless Steel washer for metal

Brass locknut

1/8” 1x19 stainless steel

cable

Pre-attached threaded stud

262 Series

Pull-Lock® Fitting

with cap

1/8” and 3/16” 1x19 stainless

steel cable

Pre-attached swaging stud

Invisiware®

Receiver

Stainless Steel washers

Tools needed for 102 Series:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable9/32 drill bit for threaded stud installation29/64 drill bit for Pull-Lock® installation1/8 hex wrench for holding the stud7/16 wrench for tightening jam nutsCable cutting tool If using post protector tubes, 1/4 drill bit

Or, you can use the 102 Series.The tensioning device is a 2-7/8” long threaded stud which installs on the back side of one end post. A brass hex nut and some metal thread (both covered by an end cap [CAP-S/S]) will extend beyond the back of the post on one end. A Pull-Lock® fitting is installed through the other end. The 102 Series can also be used in a stair-to-landing application with post protector tubes.

Cable Length PART NO. PART NO.

1/8” cable 3/16” cable

5’10’15’20’25’30’40’50’

1020510210102151022010225102301024010250

10205-610210-610215-610220-610225-610230-610240-610250-6

Series 102 Kits

Page 10: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

813.988.2628 | www.nationwideindustries.com10

Cable Runs on a Pitch

Through-the-Post Mount Metal Posts

The cleanest approach to running cable on a pitch is to drill through both end both posts on the square (NOT at the angle of the stairs). No beveled washers necessary*. Only intermediate posts need to be drilled on the angle of the stairs.*Not true for flat bar, which still needs to be drilled on the angle, requiring beveled washers.

For 1-1/2” metal square tube, use the 232 Series with 1/2" spacers. For 2” square tube, use the 232 Series. For 2-3/8” square tube, use the 224 Series. The tensioning device is respectively: a 2" long Receiver (and spacer, ordered separately) for the 212 Series stairs, a 2" Receiver for the 232 Series, and a 2-3/8" Receiver for the 224 Series, each of which install through the metal post on one end. A Pull-Lock® fitting of the same length is installed through the other end. Invisiware® Receiver

with Delrin® washer

Pull-Lock® with Delrin® washer

2” Invisiware® Receiver and 1/2” spacer with Delrin® washer

2” Pull-Lock® with Delrin® washer

Cable Length PART NO.

1/8” cable

5’10’15’20’25’

1½” or 2” Metal Post

1½” or 2” Metal Post

2320523210232152322023225

23205-623210-623215-623220-623225-6

3/16” cable

PART NO.

Series 232 Kits

Cable Length PART NO.

1/8” cable2-3/8” Metal

Post2-3/8” Metal

Post

2240522410224152242022425224302244022450

22405-622410-622415-622420-622425-622430-622440-622450-6

3/16” cable

PART NO.

Series 224 Kits

5’10’15’20’25’30’40’50’

Tools needed for 232 and 224 Series:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable29/64 drill bit for Receiver® and Pull-Lock® installation3/16 hex wrench for tensioning ReceiverCable cutting tool

Post Size: Kit for stairs: 1-1/2”: 232 Series plus spacers 2”: 232 Series 2-3/8”: 224 Series

Pull-Lock® Fitting

with cap

1/8” and 3/16” 1x19 stainless

steel cable

Pre-attached swaging stud

Invisiware®

Receiver

Delrin® washers for use with metal posts

Series 232 for 1½" posts

Series 232 or 224

Order 1/2" spacer (SPC-R6-.500) separately, see Tools and Essentials section.

Page 11: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

www.nationwideindustries.com | 813.988.2628 11

Cable Runs on a Pitch

Through-the-Post Mount Metal Posts

Tools needed for 102 Series:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable9/32 drill bit for threaded stud installation29/64 drill bit for Pull-Lock® installation1/8 hex wrench for holding the stud7/16 wrench for tightening jam nutsCable cutting tool

Or, you can use the 102 Series.The tensioning device is a 2-7/8" long threaded stud which installs through the metal post on one end. A Pull-Lock® fitting is installed through the other end. Again, both end posts are drilled on the square, not at the angle of the stairs.

Threaded Stud with washer and cap

Pull-Lock® with Delrin® washer

Pull-Lock® with Delrin® washer

Threaded Stud with washer and cap

Pull-Lock® in1-1/2” x 1-1/2” SQ. TUBE

Pull-Lock® in2” x 2” SQ. TUBE

102 Series

Pull-Lock® Fitting

with cap

Stainless Steel washer for wood

Stainless Steel

washer for wood

Delrin® washerfor metal

Stainless Steel washer for metal

Brass locknut

1/8” 1x19 stainless steel

cable

Pre-attached threaded stud

Optional Cap for Threaded StudFinish the look of your 102 Kit cable runs with our stainless steel cap to cover the brass locknut. Order one CAP-S/S for each locknut.

Cable Length PART NO. PART NO.

1/8” cable 3/16” cable

5’10’15’20’25’30’40’50’

1020510210102151022010225102301024010250

10205-610210-610215-610220-610225-610230-610240-610250-6

Series 102 Kits

Page 12: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

813.988.2628 | www.nationwideindustries.com12

Top posts are often corner posts, which may require the stair run to connect to the face of the post. The top and bottom of the cable run would be connected perpendicular to those posts, and only the intermediate posts would be drilled on the angle for the cable to run through.

Use the 500 Series for any type of post: for wood posts, use the 500-W Series; for metal posts, use the 500-M series; for sleeved posts with an outside diameter greater than 4½”, use the 500-C series.The tensioning device is an Adjust-a-Body® with Threaded Eye, which attaches via a mounting screw to the lag eye, threaded tab, or extended length lag eye, depending on the kit. A Push-Lock® with Threaded Eye attaches the same way to the other end.

500-W SeriesThe 500-W Series can be used to go up a stair and across a landing by inserting post protector tubes (order CS-TUBE separately) in the break-over post. The tube will prevent the cable from carving a groove into your post where it exits at an angle.

Face MountCable Runs on a Pitch

Wood, Metal, and Sleeved Posts

Push-Lock® with Threaded Eye and Lag Eye

Adjust-a-Body® with Threaded Eye and Lag Eye

5’10’15’20’25’30’40’50’

50005-W50010-W50015-W50020-W50025-W50030-W50040-W50050-W

50005-6W50010-6W50015-6W50020-6W50025-6W50030-6W50040-6W50050-6W

Series 500-W Kits for Wood Posts 1/8” cableCable

Length PART NO. PART NO.3/16” cable

500-W Series

Push-Lock® Threaded

Eye

Adjust-A-Body® with Threaded Eye

SC-6 Screw

SC-6 Screw

Lag Eye Lag Eye

1/8” and 3/16” 1x19 stainless

steel cable

Pre-attached swaging ferrule

Push-Lock® with Threaded Eye and Lag Eye

Adjust-a-Body® with Threaded Eye and Lag Eye

Post Protector Tube

Tools needed for 500-W Series on stairs:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable9/32 drill bit for Lag Eye installation7/16 wrench for tensioning Adjust-a-Body®

5/32 hex wrench to tighten mounting screwsCable cutting toolIf using post protector tubes, 1/4 drill bit

For post protector tubes, see Tools and Essentials section.

Page 13: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

www.nationwideindustries.com | 813.988.2628 13

Face Mount Wood, Metal, and Sleeved Posts

Cable Length PART NO. PART NO.

1/8” cable 3/16” cable

5’10’15’20’25’30’40’50’

50005-M50010-M50015-M50020-M50025-M50030-M50040-M50050-M

50005-6M50010-6M50015-6M50020-6M50025-6M50030-6M50040-6M50050-6M

any sizepost

any size post

Series 500-M Kits for Metal Posts

Tools needed for 500-M Series on stairs:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cableCutting tap drill bit I (for pilot hole) and 5/16-24 tap for threaded tab installation7/16 wrench for tensioning Adjust-a-Body® 5/32 hex wrench to tighten mounting screwsCable cutting tool

Tools needed for 500-C Series:5/32 drill bit if 1/8” cable, 7/32 if 3/16” cable9/32 drill bit for Lag Eye installation7/16 wrench for tensioning Adjust-a-Body®

5/32 hex wrench to tighten mounting screwsCable cutting tool

5’10’15’20’25’30’40’50’

50005-C50010-C50015-C50020-C50025-C50030-C50040-C50050-C

50005-6C50010-6C50015-6C50020-6C50025-6C50030-6C50040-6C50050-6C

Series 500-C Kits for Wood Posts with Composite Sleeves

1/8” cableCable Length PART NO. PART NO.

3/16” cable

500-C SeriesAs it is not recommended to bend cable through a sleeved post, stair to landing for sleeved posts would be two separate runs.

500-M SeriesThe 500-M Series is perfect for going up a stair and across a landing as is.

Adjust-A-Body® with Threaded Eye and Extended Length Lag Eye

Push-Lock® with Threaded Eye and Extended Length Lag Eye

Adjust-A-Body® with Threaded Eye and Extended Length Lag Eye

Pusan

500-C Series

Push-Lock® Threaded

Eye

Adjust-A-Body® with Threaded Eye

SC-6 Screw

SC-6 Screw

Extended LengthLag Eyes

1/8” and 3/16” 1x19 stainless

steel cable

Pre-attached swaging ferrule

Adjust-A-Body® with Threaded Eye and

Threaded Tab

Push-Lock® with Threaded Eye and Threaded Tab

500-M Series

Push-Lock® Threaded

Eye

Adjust-A-Body® with Threaded Eye

SC-6 Screw

SC-6 Screw

Threaded Tab

Threaded Tab

1/8” and 3/16” 1x19 stainless

steel cable

Pre-attached swaging ferrule

Page 14: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

813.988.2628 | www.nationwideindustries.com14

Stainless Steel Cleaner and ProtectantDissolve minor corrosion, then leave a protective coating that lasts for months. Includes an 8-oz. spray-on rust and stain remover and a 4-oz. bottle of protectant.

Order E-Z Clean

Cut-off Tool Used to cut cable flush with the end of Pull-Lock® fittings, and to cut excess threads off stud-type tensioners. Includes mandrel and two cut-off wheels.

Order CUT-OFF KIT

Cable Tension GaugesCheck the tension on your cables with these easy-to-use gauges.

Order PT-CR for cable diameter of 1/8”, 3/16” and 1/4”

Cable Cutter For burr-free cutting of cable.

Order C-7HIT for light-duty use to cut 1/8” dia. cable

Tools and EssentialsStainless Steel Cable Brace1/4” x 1” in 2 lengths, for 36” and 42” high rails. Holes pre-drilled at 3-1/8” on center, 10 holes in short length, 12 in long. For use between structural posts to keep cables code-compliant on level runs. Weld to metal frames; use cable brace floor plates for attaching to wood.

Order CB-34.5-SS-10 or CB-40.5-SS-12

Stainless Steel Cable Brace for Stairs1/4” x 1” in 2 lengths, for 36” and 42” high rails. Slots pre-drilled at 3-1/8” on center, 10 slots in short length, 12 in long. For use between structural posts to keep cables code-compliant on stair runs. Weld to metal frames; use cable brace floor plates for attaching to wood. Must be field-chamfered to match stair angle.

Order CBS-34.5-SS-10 or CBS-40.5-SS-12

Stainless Steel Cable Brace Floor PlateFor mounting cable braces to top or bottom rail or deck. 2-1/4” x 1-1/4” x 1/4”, #4 Finish Stainless Steel.

Order FLP-CBS Install with 1/4” flathead screw, purchased separately.

Anodized Aluminum Cable Brace3/4” x 3/4” tube, 42” long for cutting down to any size rail height. Holes pre-drilled at 3-1/8” on center, 13 holes total. For use between structural posts to keep cables code compliant on level runs. Use cable brace plugs to attach to top and bottom rail or deck.

Order CB-42-AN-AL-13-P

Black Aluminum Cable BraceOrder CB-42-BL-AL-13-P

Anodized Aluminum Cable Brace for Stairs3/4” x 3/4” tube, 42” long for cutting down to any size rail height. Comes undrilled so slots can be field-drilled to match cable array.

Order CB-42-AN-AL-P

Black Aluminum Cable Brace for StairsOrder CB-42-BL-AL-P

Cable ReleaseFor 1/8” Push-and Pull-Locks® only.

Releases cable from Push-Lock® and Pull-Lock® type fittings before cables are tensioned.

Order PL-KEY

Optional Cap for Threaded StudFinish the look of your 102 Kit cable runs with our stainless steel cap to cover the brass locknut. Order one CAP-S/S for each locknut.

Page 15: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

www.nationwideindustries.com | 813.988.2628 15

Stainless Steel Post Protector TubeThe post protector tube is inserted into a wood post where the cable enters/exits the post at an angle to keep the cable from biting into the wood.

Order CS-TUBE

Push-Lock® Lag DriverThe Push-Lock® Lag Driver is designed to simplify installing your one-piece Push-Lock® Lags (P/Ns PL-LAG-4 and PL-LAG-6) into wood posts. The driver slides over the wrench flat on the fitting, allowing you to then turn the Push-Lock® Lag into the post with either a ratchet or a drill.

Order DRIVER PL-LAG

Other Cable Railing Kits available from Ultra-tec®

Tools and Essentials

672 Series

371 Series

272 Series

601 Series

272 Series (both ends through-the-post) 3½” Invisiware® Receiver to Push-Lock® Stud with 2-5/16" Receiver Tensioners on both ends allow this kit to go around two 90˚ turns.

601 Series (one end through-the-post, other end face-mounted) 3½” Invisiware® Receiver to Push-Lock® Lag.

672 Series (one end through-the-post, other end face-mounted) Adjust-a-Body® with Hanger Bolt to Push-Lock® Stud with 1½" Receiver Tensioners on both ends allow this kit to go around two 90˚ turns.

371 Series (both ends face-mounted) Adjust-a-Body® with Hanger Bolt to Push-Lock® Turnbuckle with Hanger Bolt. Tensioners on both ends allow this kit to go around two 90˚ turns.

272 Series (both ends through-the-post) 3½” Invisiware® Receiver to Push-Lock® Stud with 2-5/16" Receiver Tensioners on both ends allow this kit to go around two 90˚ turns.

702 Series for 1½” posts703 Series for 2” posts

(one end through-the-post, other end face-mounted) Invisiware® Receiver to Push-Lock® Threaded Bolt.

773 Series (one end through-the-post, other end face-mounted) Adjust-a-Body® with Threaded Bolt to Push-Lock® Stud with 1½" Receiver Tensioners on both ends allow this kit to go around two 90˚ turns.

471 Series (both ends face-mounted) Adjust-a-Body® with Threaded Bolt to Push-Lock® Turnbuckle with Threaded Bolt. Tensioners on both ends allow this kit to go around two 90˚ turns.

Kits for wood posts Kits for metal posts

773 Series

471 Series

272 Series

702 and 703 Series

Kits for wood posts with composite sleeves

Stainless Steel SpacersUsed to support thin-walled double end post design or allow for Receiver extension in a stair system.

CABLEDIA.

PARTNO.

OUTSIDEDIA.

WALL THICKNESSLENGTH

5/8”5/8”

.500”

.970”.083”.083”

1/8”, 3/16”1/8”, 3/16”

SPC-R6-.500SPC-R6

TYPE 316 STAINLESS STEEL

371-C Series (both ends face-mounted) Adjust-a-Body® with Extended Length Hanger Bolt to Push-Lock® Turnbuckle with Extended Length Hanger Bolt.

4X4 WOOD POST

371-C Series

Page 16: Cable Railing Kit Application Guide - Nationwide …...cable railing through a corner, do not bend the cable past 45⁰ at any one time. If turning 90⁰, a 2-step turn using a double

Make a bird’s eye drawing of your project. Include railing lengths, end and corner post locations, stairs and any angles/turns your railing takes. Please include the following:

✓ What size post?

✓ What material (wood, composite sleeve, stainless steel)?

✓ If composite sleeve, what is the outside diameter when installed?

✓ What is the height of the railing?

✓ Are you using a bottom rail?

✓ Are you using single posts at corners or a double post configuration?

✓ Do you have 3½” of space behind end posts to allow for installation of Receivers and Pull-Locks®?

✓ What diameter cable are you using (1/8” or 3/16”)?

Your Project

Nationwide Industries 10333 Windhorst Road

Tampa, FL 33619813.988.2628 | Fax: 813.988.3465

E-mail: [email protected] | www.nationwideindustries.com