CABAC Instruction Manual - ALHAPAT and SUPAPAT€¦ · has been chosen under SYSTEM SETTI GS eg...

14
Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147 Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz 1

Transcript of CABAC Instruction Manual - ALHAPAT and SUPAPAT€¦ · has been chosen under SYSTEM SETTI GS eg...

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

1

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

2

Getting the most from your AlphaPAT

SupaPAT Carry Bag

Side Access Flaps

Easy Cord Access

Top Access Flap

Storage Pockets

Designed with the Customer in Mind

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

3

ALPHAPAT SUPAPAT IFORMATIO SHEET

(OT REQUIRED IF THE ALPHAPAT HAS BEE BOUGHT AS PART OF A SUPAPAT SYSTEM THIS WILL ALREADY HAVE BEE SET)

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

4

1. IITIAL PAT CHECK/SETUP AFTER SHIPPIG PRITER

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

5

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

6

2. MI2142 ALPHAPAT SETUP FOR SUPAPAT (IF THE ALPHAPAT HAS BEE BOUGHT AS PART OF A SUPAPAT THIS WILL ALREADY HAVE BEE SET)

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

7

1. SOFTWARE – SIMPLYPATS 6

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

8

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

9

OT JUST ALPHAPAT

Corresponds to: SimplyPATs Field

2. DOWLOADIG TO A PC/LAPTOP

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

10

IMPORTAT: Load the software disc that comes with the USB converter.

CORRECT DOWLOAD SEQUECE FIRST– O THE ALPHAPAT TESTER DO OT GO AY FURTHER— GO TO YOUR COMPUTER SOFTWARE PROGRAMME SIMPLYPATS SECOD—Plug in Cable between PAT and Computer THIRD—O YOUR COMPUTER SOFTWARE PROGRAMME : “DOWLOADIG Z/Aus AlphaPAT then checking Ports” FOURTH—BACK TO ALPHAPAT Tester

i) o results found—see iv) below also if data is not entered in PAT fields then information will not be in the Programme ii) Correct baud rate—9600 iii) Check cable – RS232 cable in correct connection—not in scanner connection iv) Asterisk in under Appl in download screen on ALPHAPAT TESTER v) Check dates for download

vi) Correct Four step sequence as in o.4b.ii) is used to download vii) Is SimplyPATs computer programme registered and password

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

11

entered into the programme see 3.a.i) & ii). viii) Shut down PAT and Computer and restart both and try again ix) Data in wrong fields on SimplyPATs programme—make sure correct tester has been chosen under SYSTEM SETTIGS eg MetrelAlphaPAT (Z/AUS). If the wrong tester has been chosen then the data fields will be incorrect.

3. SUPAPAT SYSTEM DOES OT PRIT A LABEL or prints half label/Two labels

OTE THIS WILL ERASE AY TESTS YOU HAVE DESIGED I THE CUSTOM MEU (not saved test results in memory) MAI MEU Press Enter SET UP Press Enter Scroll down to reveal ORIGIAL SETTIGS Press Enter Highlight YES with left arrow Press Enter PRESS ESC to return to main menu

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

12

4. FREQUETLY ASKED QUESTIOS/PROBLEMS try turning printer and AlphaPAT off and back on. Is the red light on the printer on? Check labels and ribbon replace as necessary and turn off and back on.

put an asterisk in the Appl box on Recall Results Menu of PAT. Check dates fields.

turn Pat off and back on send AlphaPAT only back to seller for repair.

could be out of labels/ribbon, memory confused. Check labels, ribbon and turn off and back on.heck Settings in SimplyPATs programme the wrong tester has probably been selected. Under Settings, System Settings choose Metrel—AlphaPAT (Z/AUS) use/purchase a USB converter (available from Metrotest on 1800 789 973 Au or Z 0800 638 768 —remember to load the disk that comes with the USB adaptor to your laptop.

On the top tool bar of SimplyPATs 6 choose ‘Records’ and then from the drop down menu ‘List Sites’ from where you can save out the individual sites within the download.

use the up and down arrow keys below the Enter key. CHECK THE FIRMWARE VERSIO under MAI MEU—SET UP— ISTRUMET DATA the AlphaPAT has to have Firmware version 1.38Z or higher to have all the fields. you will need to pull back the outside casingon the power connector and then make sure it goes click when properly secured – failure to do this will mean that the power connector will drop out. AlphaPAT is set onSED TO PRITER (2). In the SED RESULTS screen SED TO PRITER (1) should be chosen instead you will need to pull the plug out of either the back of the printer or the mains plug – this button has been disabled to prevent printer drivers from being wiped by holding this and the feed button down together which can causes this to happen. yes you need the Sato Printer Download Utility Software Kit which will enable you to do this yourself quickly and easily. Otherwise contact Metrotest.Com Ltd and we can upload a new printer logo for you.

7. PRITER FILES – CHAGIG LOGOS

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

13

Customer Care Australia P: 13122 F: 1300 303 310 E: [email protected] W:cabac.com.au A: Distribution Pl, Seven Hills NSW 2147Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz

14

Respond [OK] – then fix whatever condition applies ( i.e. install the driver or connect the printer USB cable to the PC).

Respond [OK] – then fix whatever condition applies ( i.e. install the driver or connect the printer USB cable to the PC).