Instrucciones montaje mesa de ping pong cornilleau 510 outdoor
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009. CLUSTER / STAFF Action items C....
-
Upload
myron-dickerson -
Category
Documents
-
view
213 -
download
1
Transcript of CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009. CLUSTER / STAFF Action items C....
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
CLUSTER / STAFF Action items
C. Burlaud, P. Robert, M. Maksimovic, N. Cornilleau-Wehrlin, Y. De Conchy,
L Mirioni, V. Bouzid.
LPP: Laboratoire de Physique des plasmas.
1. Status of data production: STAFF-SC & STAFF-SA.
2. Status of open action items.3. Data delivery plan for measurements
from years 2006-2010.4. Documents.
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
1. Status of data production:a. STAFF-SC: mode NBR and HBR
Delivered to CAA
Produced to CAA
Num. of files
Level
ContentProduct
Science data
None
Version 0301 Jan. 2001
to31 Sep. 2007
C?_CP_STA_CWF_HB
R
None1 file/
1 sat./24h
2
Calibrated
Waveform
C?_CP_STA_CWF_NB
R
C?_CP_STA_DWF_HB
R
Version 0201 Jan. 2001
to31 Dec. 2006
1 file/1 sat./24h
1Decommutat
edWaveform
C?_CP_STA_DWF_NB
R
Difference between version 3 and 2:New dataset headers (ceh format) have been created to include
caveat files. The laboratory name and emails have been updated.
Jan. 2007 DWF (v. 03) has been already uploaded:Once the integration in the CAA DB checked, the full year will
follow. The production of year 2008 DWF: It will start soon, as
we got 2008 TCOR file recently.
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
1. Status of data production:
a. STAFF-SC: mode NBR and HBR
Version 02 01 Jan. 2001 to
31 Jul. 2009
Version 0201 Jan. 2001
to31 Dec.
2005
Produced to CAA
CL_CG_STA_SC_SPECTRO_HBR
Version 02 01 Jan. 2001 to
31 Jul. 2009
1 file/4 sat./
3h3
Spectrogramsplots
CL_CG_STA_SC_SPECTRO_NBR
C?_CP_STA_CS_HBR
Version 0201 Jan. 2001 to
31 Dec. 2005
1 file/1 sat./24h
2Calibrate
d Spectra
C?_CP_STA_CS_NBR
Delivered to CAA
Num. of
files
Level
ContentProduct
A Calibrated Spectra new version (3) : New dataset headers (ceh format) have been created to include
caveat files, name lab, emails have been updated. The SI_CONVERSION metadata has been corrected and this changes is mentioned in the dataset caveat metadata.
The CS production in this new version will re-start: Year 2006/2007/2008.
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
1. Status of data production:
Spectrogram plots: Spectrogram plots: produced with a produced with a version 01 software.version 01 software.
New dataset is coming: New dataset is coming:
- Calibrated WaveForms (CWF).- Calibrated WaveForms (CWF).
- We hope to start the production by - We hope to start the production by the end of the year. Still a lot of the end of the year. Still a lot of validation work to do…validation work to do…
- See P. Robert previous presentation.- See P. Robert previous presentation.
a. STAFF-SC
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
1. Status of data production:
Delivered
to CAA
Produced
To CAA
Num. of
files
Level
ContentProduct
Science data
Spectral Matrix C?_CP_STA_SM
Power Spectral Density
C?_CP_STA_PSD
Version 301 Jan.
2001 to
31 Aug. 2008
Version 401 Jan. 2001
to 31 Jun. 2009
1 file /1 sat. /
24h2
Automatic Gain control
C?_CP_STA_AGC
Difference between version 3 and 4:Difference between version 3 and 4:- New dataset headers (ceh format) have been created to New dataset headers (ceh format) have been created to
include caveat files, name lab, emails have been updated.include caveat files, name lab, emails have been updated.- PSD negative values have been removed as requested by PSD negative values have been removed as requested by
CAA.CAA. Auxilliary data:Auxilliary data: CAVEATS : new cef files! CAVEATS : new cef files!- SM: PSD negative values and period with no tsrp recorded.SM: PSD negative values and period with no tsrp recorded.- PSD: period with no tsrp.PSD: period with no tsrp.
b. STAFF-SA: All mode
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
1. Status of data production:
Polarisation and Propagation Parameter Polarisation and Propagation Parameter (PPP)(PPP)
- PPP: cef format has been defined.PPP: cef format has been defined.- Some tests have already started to do the Some tests have already started to do the
production.production.- FGM spin resolution have been locally FGM spin resolution have been locally
downloaded from CAA.downloaded from CAA.- Ondrej Santolik will deliver us a module Ondrej Santolik will deliver us a module
to integrate FGM spin resolution data to integrate FGM spin resolution data from CAA in PRASSADCO code to produce from CAA in PRASSADCO code to produce PPP PPP by the end of novemberby the end of november..
b. STAFF-SA: L3 products
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
2. Status of open action 2. Status of open action items: items:
Cross- Calibration 8th Action ItemsCross- Calibration 8th Action Items AI-45:AI-45: OPENOPEN, , new date due: 10th Cross-Calibration workshop. new date due: 10th Cross-Calibration workshop. Cross calibration study between STAFF-SA and WBD. STAFF Cross calibration study between STAFF-SA and WBD. STAFF
team had to find the best solution. team had to find the best solution. Ondrej Santolik has been contacted and will work on it. Ondrej Santolik has been contacted and will work on it.
He will give us something by the end of NovemberHe will give us something by the end of November..
AI-1-2:AI-1-2: OPENOPEN, , new date due: 30 Sept. 2009.new date due: 30 Sept. 2009. PSD negative values:PSD negative values: negative values have been negative values have been
replaced by a fillvalue. New products have been produced replaced by a fillvalue. New products have been produced and will be redelivered soon. and will be redelivered soon.
SM/PSD caveat files, concerning no TSRP (Sun SM/PSD caveat files, concerning no TSRP (Sun Reference Pulse):Reference Pulse):
It is under process. It is under process. SM caveat filesSM caveat files, concerning PSD negative values that , concerning PSD negative values that
could be used to calculate the diagonal terms of the could be used to calculate the diagonal terms of the spectral matrix.spectral matrix.
In progress, see previous slide.In progress, see previous slide.
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
CAA Operational Review OR4CAA Operational Review OR4R2a. STAFFR2a. STAFF – The board requests that the – The board requests that the
production of search coil CWF and SA production of search coil CWF and SA polarization and propagation data sets is polarization and propagation data sets is undertaken as rapidly as possible to ensure undertaken as rapidly as possible to ensure delivery of all data by May 2010: delivery of all data by May 2010:
All efforts are done for this:All efforts are done for this:Calibrated Wave form data will be Calibrated Wave form data will be
produced and delivered to CAA. The produced and delivered to CAA. The continuous calibration is under study (see continuous calibration is under study (see P. Robert presentation).P. Robert presentation).
STAFF SA polarisation and propagation STAFF SA polarisation and propagation parameters : see previous slide. parameters : see previous slide.
2. Status of open action 2. Status of open action items: items:
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
3. 3. Data delivery plan for measurements from years 2006-
2010.
2002-20092001? *SA Polarisation/Propagation New
2009End of 200801/2001
– 08/2008
SA AGC/ PSD / SM
2002 - 2009
Jan. 2001? *SC CWF New
2009200831 Jul. 2009
SC Images
SC Complex spectra
20092007-2008
2006 to 2008
2006 2005
SC DWF
Plans :2010
Plans :2009
DoneYearProduct
* LPP is going to move from Velizy to Palaiseau by the * LPP is going to move from Velizy to Palaiseau by the end of the year.end of the year.
CAA 10th Cross Calibration Workshop, Paris, France, 2-4th Nov. 2009.
4. Documents4. Documents ICD:ICD: It has been updated but we are waiting for It has been updated but we are waiting for
new updates.new updates.- New datasets headers have been produced and New datasets headers have been produced and
delivered to include easily caveats in the future. delivered to include easily caveats in the future. They are described in the ICD.They are described in the ICD.
- New caveats files (cef format) for SM and PSD New caveats files (cef format) for SM and PSD dataset (STAFF-SA).dataset (STAFF-SA).
- 2 new datasets will be described:2 new datasets will be described: STAFF-SC: Calibrated WaveForm (CWF).STAFF-SC: Calibrated WaveForm (CWF). STAFF-SA: Polarization and Parameterization STAFF-SA: Polarization and Parameterization
Parameter (PPP).Parameter (PPP). User guide:User guide: has to be updated following the has to be updated following the
recommendations of CAA (new CAA website recommendations of CAA (new CAA website interface, new datasets, new caveats).interface, new datasets, new caveats).
Calibration Report:Calibration Report: once tests on the new once tests on the new calibration method will be finished, the CR will calibration method will be finished, the CR will be updated. be updated.