C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System...

16
C09. S08. P02 – P07 CasoLine QUICK -LOCK Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section includes updated information, added since it was first published in December 2015. Last updated 10/06/2019 !

Transcript of C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System...

Page 1: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09.S08.P02–P07 CasoLinequick-lock Corridor System IncludingC09.S01.P02–P08

Soundabsorbingsolutionsintroduction

Thissectionincludesupdatedinformation,addedsinceitwasfirst

publishedinDecember2015.

Last updated 10/06/2019!

Page 2: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09

Intr

odu

ctio

nSo

un

d ab

sorb

ing

solu

tion

s

Sound absorbing solutionsThis section details sound absorbing solutions which both provide reverberation control and improved aesthetics

Page 3: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S01. P02 0115 945 6123 [email protected]

C09Introdu

ctionSou

nd absorbin

g solution

s

Sound absorbing solutions

British Gypsum sound absorbing solutions, incorporating Gyptone, Rigitone and Gyprex tiles, boards and planks, combine exciting aesthetic design with excellent acoustic absorption performance.

With performance levels up to Class A sound absorption, our ceilings meet the demands of industry standards in sectors such as education, healthcare and residential, making them ideal for schools, high-rise multi-occupancy buildings, healthcare buildings as well as offices and retail premises.

Our quick reference sound absorbing solutions guide, below, allows you to understand the key benefits of each solution, including grid concealment and flange size. Further detail can be found within the subsequent sections to help further refine your choice.

Description System Page

A suspended ceiling system, that can be used in conjunction with Gyptone and Rigitone ceiling boards to create a seamless, monolithic appearance.

CasoLine mf C09. S02. P02

Concealed suspended ceiling system for constructing curved ceilings.

CasoLine curve C09. S03. P02

A concealed ceiling system with minimal cavity depth suitable for a wide range of installations, and utilising the same components as GypLyner universal wall lining solution.

GypLyner universal C09. S04. P02

A demountable, exposed 24mm wide grid ceiling system compatible with a range of Gyprex, Gyptone and tiles.

CasoLine quick-lock grid t24 C09. S05. P02

A demountable, exposed 15mm wide grid ceiling systemcompatible with a range of Gyprex, Gyptone and tiles.

CasoLine quick-lock grid t15 C09. S06. P02

The ideal ceiling solution for spanning between corridor walls, unsuspended up to 2.4m incorporating Gyptone Planks.

CasoLine quick-lock Corridor Systems

C09. S08. P02

Page 4: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S01. P03 british-gypsum.com

C09

Intr

odu

ctio

nSo

un

d ab

sorb

ing

solu

tion

s

Sound absorbing solutions

Areas to consider when specifying

Acoustics

A suspended ceiling can provide two levels of acoustic performance;

sound insulation, preventing the passage of sound into the room

from an external source, and sound absorption, which is the control

of undesirable sound within the room, in the form of reverberation.

Ceiling systems incorporating products such as Gyproc SoundBloc

provide the greatest level of sound insulation, while the Gyptone or

Rigitone ranges provide excellent sound absorption performance for

reverberation control.

Aesthetics

The ceiling provides a large blank canvas which can form part of the

overall interior design scheme. Patterns, colours and shape can all

be easily incorporated using products such as Gyptone or Rigitone.

A lower key, minimalist appearance can be achieved with the clean,

white finish of Gyprex systems.

Air quality

Historically, the role of a suspended ceiling has been limited to

passive performance in terms of aesthetics, acoustics and fire

resistance. With our VOC-absorbing ACTIVair technology now

available as standard in all Gyptone and Rigitone products, the

ceiling can now take on a more active functional role within the

room. It actively improves the indoor air quality and provides the

associated benefits to the occupants in the space below.

Refer to C02. S01. P49 – Indoor air quality.

Accessibility

Whatever type of ceiling is designed (table 1), access to the cavity

above the ceiling will inevitably be required. whether this is for

inspection, maintenance or repair of HVAC and similar services.

A seamless system such as CasoLine mf can accommodate access

points in the form of Profilex or Gyptone access hatches, whilst

lay-in grid ceilings have the advantage of allowing access at

virtually any point across the ceiling.

Types of ceiling

Demountable

A traditional demountable ceiling consists of individual ceiling tiles

which are laid into a metal grid. More recent innovations of the

traditional lay-in grid ceiling include the CasoLine quick-lock-grid

Corridor System. The plank system can be used to provide totally

clear, unobstructed access to M&E services in commercial buildings.

Lay-in ceilings are generally simple to install, easy to maintain and

can be dismantled, repositioned or even reused.

Seamless

Systems such as CasoLine mf or GypLyner universal ceilings provide

a smooth, seamless monolithic ceiling. These types of ceiling can

be used to achieve high levels of sound insulation, absorption, or

both. These systems provide a large degree of flexibility and can be

installed horizontally, sloped, vertically or - using CasoLine curve -

giving a contoured shape.

Cleanability

Commercial ceilings are subject to a diverse range of cleaning

regimes. A hospital ceiling, needs to cope with the frequent and/

or aggressive cleaning regimes required in clinical areas. Ceiling

systems such as Gyprex bio provide a wipeable vinyl surface with

an integral biocide, preventing the growth of fungi and bacteria,

including MRSA, E. coli O157 and Salmonella.

Additional Information

Our Gyptone range offers the highest level of accessibility to the

ceiling cavity. Gyptone Hatch, Gyptone Plank and the Gyptone TRAP

system are ideally suited to where regular or unrestricted access

to the cavity is required and can be used either as a stand-alone

solution or in conjunction with another Gyptone ceiling.

For full details of these products and suitable systems, please refer

to the British Gypsum Ceilings Installation Guide, available to

download from british-gypsum.com.

Table 1 – Ceiling system combinations

Demountable systems Seamless systems

T15

T24

Plan

k

Caso

Lin

e m

f

Gyp

Lyn

er

Caso

Lin

e cu

rv

e

Gyprex tiles

Gyptone Tiles

Gyptone Plank

Gyptone board

Rigitone board

Page 5: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S01. P04 0115 945 6123 [email protected]

C09Introdu

ctionSou

nd absorbin

g solution

s

Gyptone quattro 46 (plenum depth 400mm)

Gyptone quattro 46 (plenum depth 400mm plus

100mm Isover Spacesaver Ready-Cut)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.65 0.60 0.55 0.45 0.40 0.35 0.45(L) D 0.50

0.60 0.60 0.65 0.55 0.45 0.40 0.50(L) D 0.55

Gyptone quattro 42 (plenum depth 50mm)3

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.20 0.40 0.60 0.60 0.45 0.40 0.50 D 0.55

Gyptone quattro 41 (plenum depth 187mm)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.50 0.70 0.80 0.70 0.60 0.55 0.65 C 0.70

System reference C10A014

C10A015

QUATTRO 46 Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

Gyptone performance

Table 2 – Sound absorption data for Gyptone boards

1 AC – Absorption Class.2 NRC – Noise Reduction Coefficient.3 Due to installation limitations the minimum cavity size that can be constructed with CasoLine mf or CasoLine curve system is 100mm. The sound absorption

performance for these systems is estimated to be equivalent to that of the same system built with a 50mm plenum.

All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw

is calculated in accordance

with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

QUATTRO 41

System reference C10A091

Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

QUATTRO 42 Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

System reference C10A110

Page 6: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S01. P05 british-gypsum.com

C09

Intr

odu

ctio

nSo

un

d ab

sorb

ing

solu

tion

s

Gyptone sixto 63 (plenum depth 200mm)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.35 0.60 0.70 0.60 0.55 0.55 0.60 C 0.60

Gyptone line 6 (plenum depth 400mm)

Gyptone line 6 (plenum depth 400mm plus

100mm Isover Spacesaver Ready-Cut)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.70 0.65 0.60 0.50 0.40 0.35 0.45(L) D 0.55

0.70 0.70 0.65 0.65 0.50 0.45 0.55(L) D 0.65

Gyptone quattro 47 (plenum depth 400mm)

Gyptone quattro 47 (plenum depth 400mm plus

50mm Isover Acoustic Partition Roll (APR 1200))

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.45 0.50 0.45 0.40 0.30 0.25 0.35(L) D 0.40

0.50 0.55 0.50 0.40 0.30 0.30 0.40(L) D 0.45

Gyptone performance (continued)

Table 2 (continued) – Sound absorption data for Gyptone boards

System reference C10A016

C10A017

QUATTRO 47 Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

System reference C10A001

C10A002

LINE 6 Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

System reference C10A115

SIXTO 63 Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

1 AC – Absorption Class.2 NRC – Noise Reduction Coefficient.

All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw

is calculated in accordance

with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

Page 7: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S01. P06 0115 945 6123 [email protected]

C09Introdu

ctionSou

nd absorbin

g solution

s

Rigitone performance

Table 3 – Sound absorption data for Rigitone boards

1 AC – Absorption Class.2 NRC – Noise Reduction Coefficient.3 Due to installation limitations the minimum cavity size that can be constructed with CasoLine mf or CasoLine curve system is 100mm. The sound absorption

performance for these systems is estimated to be equivalent to that of the same system built with a 50mm plenum.

All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw

is calculated in accordance

with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

System reference C10A058

C10A059

C10A069

8-15-20 SUPER Sound absorption coefficient αp

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

Rigitone 8-15-20 super (plenum depth 50mm)3

Rigitone 8-15-20 super (plenum depth 200mm)

Rigitone 8-15-20 super (plenum depth 200mm plus

50mm Isover Frame Batt 32)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.15 0.40 0.70 0.75 0.45 0.40 0.50(M) D 0.55

0.35 0.75 0.75 0.55 0.40 0.30 0.45(LM) D 0.60

0.60 0.85 0.80 0.65 0.45 0.30 0.45(LM) D 0.70

Rigitone 8/18 (plenum depth 50mm)3

Rigitone 8/18 (plenum depth 200mm)

Rigitone 8/18 (plenum depth 200mm plus 50mm Isover Frame Batt 32)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.10 0.30 0.65 0.85 0.55 0.30 0.50(M) D 0.55

0.35 0.75 0.90 0.60 0.50 0.40 0.55(LM) D 0.70

0.60 0.95 0.95 0.80 0.70 0.50 0.70(LM) C 0.85System reference C10A036

C10A037

C10A060

8/18 Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

System reference C10A125

C10A124

C10A126

8/18 Q Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

Rigitone 8/18 q (plenum depth 50mm)3

Rigitone 8/18 q (plenum depth 200mm)

Rigitone 8/18 q (plenum depth 200mm plus

25mm Isover Acoustic Partition Roll (APR 1200))

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.15 0.25 0.60 0.85 0.65 0.50 0.55(M) D 0.60

0.40 0.65 0.80 0.60 0.55 0.50 0.60 C 0.65

0.40 0.70 0.85 0.80 0.80 0.70 0.80 B 0.80

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Page 8: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S01. P07 british-gypsum.com

C09

Intr

odu

ctio

nSo

un

d ab

sorb

ing

solu

tion

s

Rigitone performance (continued)

Table 3 (continued) - Sound absorption data for Rigitone boards

1 AC – Absorption Class.2 NRC – Noise Reduction Coefficient.3 Due to installation limitations the minimum cavity size that can be constructed with CasoLine mf or CasoLine curve system is 100mm. The sound absorption

performance for these systems is estimated to be equivalent to that of the same system built with a 50mm plenum.

All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw

is calculated in accordance

with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

10/23

System reference C10A038

C10A039

C10A061

Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

Rigitone 10/23 (plenum depth 50mm)3

Rigitone 10/23 (plenum depth 200mm)

Rigitone 10/23 (plenum depth 200mm plus

50mm Isover Frame Batt 32)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.10 0.25 0.65 0.90 0.55 0.25 0.45(M) D 0.60

0.35 0.70 0.85 0.60 0.50 0.35 0.50(LM) D 0.65

0.65 0.95 0.90 0.80 0.65 0.45 0.65(LM) C 0.80

12-20/66

System reference C10A042

C10A043

C10A063

Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

Rigitone 12-20/66 (plenum depth 50mm)3

Rigitone 12-20/66 (plenum depth 200mm)

Rigitone 12-20/66 (plenum depth 200mm plus

50mm Isover Frame Batt 32)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.10 0.25 0.60 0.85 0.55 0.30 0.45(M) D 0.55

0.40 0.70 0.85 0.60 0.50 0.35 0.50(LM) D 0.65

0.55 0.95 1.00 0.85 0.70 0.55 0.70(LM) C 0.90

Rigitone 12/25 (plenum depth 50mm)3

Rigitone 12/25 (plenum depth 200mm)

Rigitone 12/25 (plenum depth 200mm plus

50mm Isover Frame Batt 32)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.05 0.25 0.65 0.85 0.65 0.50 0.55(M) D 0.60

0.35 0.75 0.90 0.65 0.55 0.40 0.55(LM) D 0.70

0.55 0.95 0.95 0.85 0.70 0.50 0.70(LM) C 0.85

12/25

System reference C10A127

C10A129

C10A128

Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

Page 9: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S01. P08 0115 945 6123 [email protected]

C09Introdu

ctionSou

nd absorbin

g solution

s

Rigitone performance (continued)

Table 3 (continued) - Sound absorption data for Rigitone boards

1 AC – Absorption Class.2 NRC – Noise Reduction Coefficient.3 Due to installation limitations the minimum cavity size that can be constructed with CasoLine mf or CasoLine curve system is 100mm. The sound absorption

performance for these systems is estimated to be equivalent to that of the same system built with a 50mm plenum.

All products have been tested to BS EN 20354 and ISO 354. The single figure rating practical sound absorption coefficient αw

is calculated in accordance

with EN ISO 11654. Suffix letters indicate where performance is limited at either low, medium or high frequencies.

Rigitone 12/25 q (plenum depth 50mm)3

Rigitone 12/25 q (plenum depth 200mm)

Rigitone 12/25 q (plenum depth 200mm plus

50mm Isover Frame Batt 32)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.10 0.30 0.65 0.90 0.80 0.60 0.60(M) C 0.65

0.35 0.75 0.90 0.70 0.65 0.50 0.65(LM) C 0.75

0.55 0.90 0.95 0.85 0.85 0.65 0.85(L) B 0.90

Rigitone 15/30 (plenum depth 50mm)3

Rigitone 15/30 (plenum depth 200mm)

Rigitone 15/30 (plenum depth 200mm plus

50mm Isover Frame Batt 32)

Practical absorption coefficient α

p

125 250 500 1k 2k 4k αW

AC1 NRC2

0.10 0.25 0.60 0.85 0.55 0.30 0.45(M) D 0.55

0.35 0.70 0.85 0.60 0.50 0.35 0.50(LM) D 0.65

0.60 0.95 1.00 0.85 0.70 0.55 0.70(LM) C 0.85

System reference C10A040

C10A041

C10A062

15/30 Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

System reference C10A131

C10A130

C10A132

12/25 Q Sound absorption coefficient αp

0.0

0.2

0.4

0.6

0.8

1.0

125 250 500 1000 2000 4000

Prac

tica

l abs

orpt

ion

coe

ffic

ien

t α p

Frequency (Hz)

Page 10: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09

Caso

Lin

e q

uic

k-l

ock

Cor

rido

r Sy

stem

Sou

nd

abso

rbin

g so

luti

ons

CasoLine quick-lock Corridor SystemA corridor ceiling system that combines acoustics, aesthetics and accessibility

All our systems are covered by SpecSure® when using genuine British Gypsum and Saint-Gobain Isover products

Page 11: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S08. P02 0115 945 6123 [email protected]

C09CasoLin

e qu

ick-lock Corridor System

Soun

d absorbing solu

tions

CasoLine quick-lock Corridor System

The CasoLine quick-lock Corridor System provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.

Key benefits

— Gyptone Plank and CasoLine quick-lock can be easily removed by hand, providing total uninterrupted access to the services above for future maintenance

— Suspended ceilings are usually prone to damage in frequently accessed service areas as they cannot normally be easily removed. CasoLine quick-lock Corridor System provides easy access to plenum services within corridors, through a completely unsuspended grid that can span up to 2.4m

— There is no requirement to install hangers or soffit supports for spans 2.4m or less (1.8m if insulation laid on back); making setting out, installation and removal much easier

αw

0.65 0.75

Refer to C02. S01. P49

Refer to C01. S01. P07

Page 12: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S08. P03 british-gypsum.com

C09

Caso

Lin

e q

uic

k-l

ock

Cor

rido

r Sy

stem

Sou

nd

abso

rbin

g so

luti

ons

Building design

CasoLine quick-lock Corridor System is a metal grid system

comprising CasoLine quick-lock Main Tees and Shadowline

Mouldings CLSM04 into which Gyptone Plank can be installed.

Planning - key factors

Gyptone planks must not be loaded. Light fittings and other fixtures

should be independently supported. If Isover Acoustic Partition Roll

(APR 1200) is placed above the ceiling, the maximum

self-supporting distance is reduced to 1800mm. Hangers should be

used for increased spans.

Refer to construction detail 1.

Cavity barriers

Where cavity barriers are required, they can be formed using

Gyproc FireLine or Glasroc F multiboard screw-fixed to a simple frame.

The framing should be fixed to the structure to avoid undue loading

of the ceiling suspension grid. The bottom of the framework should

be fixed to the ceiling grid.

Refer to C06. S07. P02 – Cavity barriers.

Services

The ceiling void above the CasoLine quick-lock Corridor System

can be used to route all service requirements, including ducting,

pipework, electrical cables, and conduits. All services must be

independently supported from the structure.

Maintenance

Gyptone Plank can be cleaned using a damp cloth or soft brush.

Most standard mild detergents can be used. Gyptone Plank can be

re-decorated if required using a suitable emulsion paint and a

short-haired brush or roller (spray painting will impair sound

absorption).

Gyptone tiles with ACTIVair

Though we don’t notice them, impurities, such as Volatile Organic

Compounds (VOCs) including formaldehyde, are often present in

the air we breathe - emitted from furniture, carpets and building

materials. Long-term exposure to these can potentially cause health

problems and reduce general wellbeing. Studies have shown that

clean air, can speed up patient recovery in hospitals, reduce absence

at work, and increase pupils’ concentration at school.

ACTIVair is our latest technology designed specifically to convert

formaldehyde emissions into non-harmful inert compounds. Tests

show that ACTIVair decomposes 70% of the formaldehyde in a

controlled test environment. This clever technology continues to

work for over 50 years, and whilst alternative solutions absorb

formaldehyde, they don’t decompose them like ACTIVair, risking

re-emission at a later date.

Refer to C02. S01. P49 – Indoor air quality.

CasoLine quick-lock Corridor System performance

Table 1 – Sound absorption

Absorption

class

Sound absorption

coefficient αw

Noise Reduction

Coefficient (NRC)

Product ACTIVair

technology

available1

Plenum

depth

mm

Insulation Light

reflectance

%

System

reference

C 0.75 (L) 0.75 Gyptone quattro 55 Plank 100 50mm2 73% C10A098

C 0.65 0.70 Gyptone quattro 55 Plank 200 - 73% C10A034

C 0.65 0.65 Gyptone quattro 55 Plank 100 - 73% C10A092

C 0.65 (L) 0.65 Gyptone point 15 Plank 200 - 75% C10A010

C 0.65 0.60 Gyptone line 8 Plank 200 - 70% C10A009

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and

easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1 These systems have an ACTIVair board option available, which improves indoor air quality. Refer to C02. S01. P49 for further details. 2 50mm Isover Acoustic Partition Roll (APR 1200).

CasoLine quick-lock Corridor System design

SpecSure®

All our systems are covered by SpecSure® when using genuine British Gypsum and Saint-Gobain Isover products.

Page 13: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S08. P04 0115 945 6123 [email protected]

C09CasoLin

e qu

ick-lock Corridor System

Soun

d absorbing solu

tions

CasoLine quick-lock Corridor System construction details

CasoLine quick-lock Corridor System 15mm exposed metal grid fixing system for Gyptone Plank with edge E15/A

5

2

4

3

1

2

1

5

1

1 CasoLine quick-lock grid Main Tee CLT15P01 or CLT15P03

2 CasoLine quick-lock grid Shadowline Moulding CLSM04

3 CasoLine quick-lock grid Shadowline Moulding CLSM04 fixed

back-to-back

4 CasoLine quick-lock grid Hanger at 600mm maximum centres and

300mm maximum from each end

5 Gyptone Plank with edge E15/A

Page 14: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S08. P05 british-gypsum.com

C09

Caso

Lin

e q

uic

k-l

ock

Cor

rido

r Sy

stem

Sou

nd

abso

rbin

g so

luti

ons

CasoLine quick-lock Corridor System construction details (continued)

2

1 CasoLine quick-lock grid Main Tee CLT15P01 or CLT15P03

suitably fixed to wall at 300mm centres

2 Gyptone Plank with edge profile E15 / A

3 CasoLine quick-lock grid Main Tee CLSM04 Shadowline Moulding

(suitably fixed to wall at 300mm centres)

4 Timber batten (by others) suitably fixed to wall

Alternative perimeter

4

Standard perimeter

3

1

2

3

1

2

3

Page 15: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S08. P06 0115 945 6123 [email protected]

C09CasoLin

e qu

ick-lock Corridor System

Soun

d absorbing solu

tions

CasoLine quick-lock Corridor System components

Ceiling products ( Refer to C10. S08. P02 for details)

CasoLine quick-lock grid Hangers

High-strength adjustable hangers for suspension of

CasoLine quick-lock grid.

CasoLine quick-lock grid Main Tee CLT15P01

Main tee used with 1800mm Gyptone planks to

form CasoLine quick-lock grid Corridor System.

A wide range of Gyptone1 Plank products are

available.

Refer to C10. S08. P02 – Products, ceilings.

CasoLine quick-lock grid Main Tee CLT15P03

Main tee used with 2400mm Gyptone planks to

form CasoLine quick-lock grid Corridor System.

CasoLine quick-lock grid Shadowline Moulding

CLSM04

3m length wall profile for construction of a

CasoLine quick-lock grid Corridor System.

A

CasoLine quick-lock grid Corridor System.

E15

CasoLine quick-lock grid Corridor System.

Gypframe metal components ( Refer to C10. S02. P16 for details)

MF12 Soffit Cleat

Suspension point, one leg connected to structural

soffit and the other leg connected to suspension

hanger / wire.

Metal products (by others)

Suspension wire

Metal wire to provide support for suspended ceiling

systems.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200)

Glass mineral wool for enhanced acoustic and

thermal performance.

1 ACTIVair technology as standard.

Page 16: C09. S08. P02 – P07/media/Files/... · C09. S08. P02 – P07 CasoLine quick-lock Corridor System Including C09. S01. P02 – P08 Sound absorbing solutions introduction This section

C09. S08. P07 british-gypsum.com

C09

Caso

Lin

e q

uic

k-l

ock

Cor

rido

r Sy

stem

Sou

nd

abso

rbin

g so

luti

ons

CasoLine quick-lock Corridor System installation overview

Additional information

For full installation details, refer to the British Gypsum Ceiling Installation Guide, available to download from british-gypsum.com

CasoLine quick-lock grid Shadowline

Moulding CLSM04 is fixed to the wall at

300mm centres.

CasoLine quick-lock grid Main Tee CLT15P

sections are cut to suit the width of the

corridor. The section length should be no

more than 10mm shorter than the corridor

width. Main Tee sections are fitted into

the CasoLine quick-lock grid Shadowline

Moulding CLSM04, onto the upper recessed

flange. There is no requirement to install

hangers to support the CasoLine quick-lock

grid Main Tee sections. These sections

should not be joined and no soffit supports

or hangers are required.

Gyptone Planks are cut to fit on the lower

flange of the CasoLine quick-lock grid

Shadowline Moulding CLSM04.

This is intended to be a basic description of how the system is built.

For detailed installation guidance refer to the British Gypsum Ceiling installation guide.