BUREAU VERITAS SHENZHEN CO., LTD. DONGGUAN BRANCH 1 ELECTRICAL

12
(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 1 of 10 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 BUREAU VERITAS SHENZHEN CO., LTD. DONGGUAN BRANCH 1 Chenwu Industrial Zone No. 34, Chenwu Section, Guantai Road Houjie Town, Dongguan, Guangdong, 523942, People’s Republic of China Mr. Alec Hu Phone: 86-769-85935656 Email: [email protected] ELECTRICAL Valid to: February 29, 2020 Certificate Number: 2951.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s EPA ENERGY STAR ® Accreditation Program 2 requirements), accreditation is granted to this laboratory at the location listed above, as well as the satellite laboratory location listed below, to perform the following tests: Test Technology: Test Method(s): Emissions Unintentional Radiators Radiated & Conducted (up to 40 GHz) CFR 47, FCC Part 15B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); ICES-001; ICES-002; ICES-003; ICES-004; ICES-005; ICES-006; ICES-008; VCCI 32-1; VCCI-CISPR 32:2016 (up to 6 GHz); VCCI-V3 (up to 6 GHz); VCCI-V4; CISPR 11; EN 55011; AS/NZS CISPR 11; CISPR 13; EN 55013; AS/NZS CISPR 13; CISPR 14-1; EN 55014-1; AS/NZS CISPR 14.1; CISPR 15; EN 55015; AS/NZS CISPR 15; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; CNS 13083; CNS 13438 (up to 6 GHz); CNS 13439; CNS 13783-1; J 55013; J 55014-1; J 55015; J 55022; GB 4343.1; GB 824; GB 13837; GB 17743; GB 9254; GB/T 9383; GB/T 18595; GR 1089 Emissions Intentional Radiators Radiated & Conducted (up to 40 GHz) CFR 47, FCC Part 15 Subparts C, E, F, G, H (using ANSI C63.10:2013); KDB 905462 D02 (v02); CFR 47, FCC Part 15 Subpart D (using ANSI C63.17:2013); CFR 47, FCC Part 25;

Transcript of BUREAU VERITAS SHENZHEN CO., LTD. DONGGUAN BRANCH 1 ELECTRICAL

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 1 of 10

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

BUREAU VERITAS SHENZHEN CO., LTD. DONGGUAN BRANCH 1 Chenwu Industrial Zone

No. 34, Chenwu Section, Guantai Road Houjie Town, Dongguan, Guangdong, 523942, People’s Republic of China

Mr. Alec Hu Phone: 86-769-85935656 Email: [email protected]

ELECTRICAL

Valid to: February 29, 2020 Certificate Number: 2951.01

In recognition of the successful completion of the A2LA evaluation process (including an assessment of the

organization’s compliance with A2LA’s EPA ENERGY STAR® Accreditation Program 2 requirements),

accreditation is granted to this laboratory at the location listed above, as well as the satellite laboratory

location listed below, to perform the following tests:

Test Technology:

Test Method(s):

Emissions – Unintentional Radiators

Radiated & Conducted

(up to 40 GHz)

CFR 47, FCC Part 15B (using ANSI C63.4:2014);

CFR 47, FCC Part 18 (using MP-5:1986);

ICES-001; ICES-002; ICES-003; ICES-004;

ICES-005; ICES-006; ICES-008;

VCCI 32-1; VCCI-CISPR 32:2016 (up to 6 GHz);

VCCI-V3 (up to 6 GHz); VCCI-V4;

CISPR 11; EN 55011; AS/NZS CISPR 11;

CISPR 13; EN 55013; AS/NZS CISPR 13;

CISPR 14-1; EN 55014-1; AS/NZS CISPR 14.1;

CISPR 15; EN 55015; AS/NZS CISPR 15;

CISPR 22; EN 55022; AS/NZS CISPR 22;

CISPR 32; EN 55032; AS/NZS CISPR 32;

CNS 13083; CNS 13438 (up to 6 GHz);

CNS 13439; CNS 13783-1;

J 55013; J 55014-1; J 55015; J 55022;

GB 4343.1; GB 824; GB 13837; GB 17743;

GB 9254; GB/T 9383; GB/T 18595;

GR 1089

Emissions – Intentional Radiators

Radiated & Conducted

(up to 40 GHz)

CFR 47, FCC Part 15 Subparts C, E, F, G, H

(using ANSI C63.10:2013);

KDB 905462 D02 (v02);

CFR 47, FCC Part 15 Subpart D (using ANSI C63.17:2013);

CFR 47, FCC Part 25;

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 2 of 10

Test Technology:

Test Method(s):

Radiated & Conducted (cont’d)

KDB 558074; KDB 789033; KDB 971168; KDB 865664;

ANSI/TIA 603-D; ANSI C63.26-2015;

CFR 47 FCC Parts 22, 24, 25 (non-microwave) and 27

(using ANSI/TIA-603-D & TIA-102.CAAA-D);

KDB 971168;

CFR 47, FCC Parts 22 (non-cellular), 73, 74,

90 (non-microwave), 95, 96, 97, 101 (non-microwave)

(using ANSI/TIA- 603-D & TIA-102.CAAA-D);

KDB 300643; KDB 414788; KDB 447498; KDB 974614;

ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26-2015;

RSS-111; RSS-112; RSS-117; RSS-119; RSS-123; RSS-125;

RSS-127; RSS-130; RSS-131; RSS-134; RSS-135; RSS-137;

RSS-139; RSS-141; RSS-142; RSS-170; RSS-181; RSS-182;

RSS-192; RSS-194; RSS-195; RSS-196; RSS-197; RSS-199;

RSS-211; RSS-215; RSS-216; RSS-220; RSS-222; RSS-236;

RSS-238; RSS-243; RSS-244; RSS-247; RSS-252; RSS-287;

RSS-288; RSS-310; RSS-GEN; BETS-7;

ARIB STD-T66; ARIB STD-T67;

ARIB STD-T71 (ver 6.0); ARIB STD-T89; ARIB STD-T91;

ARIB STD-T92; ARIB STD-T93; ARIB STD-T96;

ARIB STD-T106; ARIB STD-T108;

ARIB RCR STD-1; ARIB RCR STD-29;

ARIB RCR STD-33; ARIB RCR STD-15; ARIB STD-T112;

AS/NZS 4268; AS/NZS 4771;

EN 300 220-1; EN 300 220-2; EN 300 220-3;

EN 300 220-3-1; EN 300 220-3-2; EN 300 220-4;

EN 300 330-1; EN 300 330-2; EN 300 330;

EN 300 440-1; EN 300 440-2; EN 300 440;

EN 300 328; EN 301 893; EN 300 386;

EN 300 422-1; EN 300 422-2;

EN 301 357-1; EN 301 357-2;

EN 302 291-1; EN 302 291-2;

EN 302 208; EN 302 502; EN 300 086; EN 300 113;

EN 300 296; EN 302 065-1; EN 302 065-2; EN 302 065-3;

EN 302 065-4; EN 302 065-5; EN 301 426; EN 301 441;

EN 301 681; EN 301 444; EN 303 203; EN 303 204;

EN 302 536; EN 302 537; EN 302 571; EN 301 559;

EN 303 345; EN 303 340; EN 303 372-1; EN 303 372-2;

EN 303 354; EN 301 357;

EN 300 422-4; EN 303 413; EN 303 417; EN 303 446;

ETSI ES 201 468;

IMDA TS SRD;

LP0002

Harmonic Current AS/NZS 61000.3.2; EN 61000-3-2; GB 17625.1;

IEC 61000-3-2; IEC/EN 61000-3-12; GB/Z 17625.6

Voltage Changes,

Voltage Fluctuations, and Flicker

AS/NZS 61000.3.3; EN 61000-3-3; GB 17625.2;

IEC 61000-3-3; IEC/EN 61000-3-11; GB/Z 17625.3

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 3 of 10

Test Technology:

Test Method(s):

Immunity

Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2; GB/T 17626.2;

AS/NZS 61000.4.2; CNS 14676-2

Radiated Immunity

(up to 6GHz, 10V/m)

IEC 61000-4-3; EN 61000-4-3; GB/T 17626.3;

AS/NZS 61000.4.3; CNS 14676-3

Electrical Fast Transient IEC 61000-4-4; EN 61000-4-4; GB/T 17626.4;

CNS 14676-4

Surge IEC 61000-4-5; EN 61000-4-5; GB/T 17626.5;

AS/NZS 61000.4.5; CNS 14676-5

Conducted Immunity IEC 61000-4-6; EN 61000-4-6; GB/T 17626.6;

AS/NZS 61000.4.6; CNS 14676-6

Magnetic Field Immunity IEC 61000-4-8; EN 61000-4-8; GB/T 17626.8;

AS/NZS 61000.4.8; CNS 14676-8

Voltage Dips and Short Interrupts IEC 61000-4-11; EN 61000-4-11; GB/T 17626.11;

AS/NZS 61000.4.11; CNS 14676-11

Generic Standards, Product Family

Standards and Industry Specific

Standards

IEC 61000-6-1; EN 61000-6-1; GB 17799.1;

IEC 61000-6-2; EN 61000-6-2; GB 17799.2;

IEC 61000-6-3; EN 61000-6-3; GB 17799.3;

IEC 61000-6-4; EN 61000-6-4; GB 17799.4;

CISPR 24; EN 55024; GB/T 17618;

CISPR 14-2; EN 55014-2; GB 4343.2;

CISPR 20; EN 55020; GB/T 9383; EN 50083-2;

CISPR 35; EN 55035;

IEC 61547; EN 61547;

IEC 61543; IEC 62920;

EN 55103-2; EN 50130-4; EN 50412-2-1;

ENV 50204; CNS 13783-2;

EN 61326-2-3; EN 61326-2-4; EN 61326-2-5;

IEC/EN 60974-10; IEC/EN 60255-26;

GB/T 18268.1; GB/T 18268.26; YY 0505;

EN 50121-1; EN 50121-3-2; EN 50121-4;

EN 61204-3; IEC/EN 60730-1; EN 50491-5-1;

EN 50491-5-2; EN 50491-5-3;

GB 4343.1; GB 824; GB 13837; GB 17743; GB 9254;

GB/T 9383; GB/T 18595;

EN/IEC 60601-1-2; EN/IEC 61326-1; EN/IEC 61326-2-1;

EN/IEC 61326-2-2; EN/IEC 61326-2-6; EN/IEC 61204-3;

EN/IEC 62040-2; EN 55103-1;

EN 50498; EN 50561-1; EN 50561-3;

EN 301 489-1; EN 301 489-3; EN 301 489-4; EN 301 489-5;

EN 301 489-7; EN 301 489-9; EN 301 489-17;

EN 301 489-19; EN 301 489-20; EN 301 489-23;

EN 301 489-24; EN 301 489-25; EN 301 489-26;

EN 301 489-33; EN 301 489-34; EN 301 489-52

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 4 of 10

Test Technology:

Test Method(s):

Radio Communication

(excluding protocol testing)

EN 301 511; EN 301 908-1; EN 301 908-2

Electromagnetic Fields with Regard to

Human Exposure

Household Appliances and Similar

Apparatus

IEC 62233; EN 62233; IEC 62493; EN 62493

RF Exposure

(excluding SAR and HAC testing)

Australian Communications Authority (ACA)

Radiocommunications (Electromagnetic Radiation –

Human Exposure);

EN 50371; EN 50385; EN 50392; EN 62311;

EN 62479; EN 50566; RSS-102

Acoustics Testing EN 50332-1; EN 50332-2

Photovoltaics IEC 62116; IEC 61727; G83/2; BDEW; TR3; TR4;

VDE-AR-N 4105; VDE0124-100; VDE0126-1-1+A1;

RD 1699/RD661; IEC 61683; NRS 097-2-1; G59/3;

AS3100; NB/T 32004; ÖNORM E8001-4-712;

SI 4777.2; SI 4777.3; IEC/EN 62477-1; UL 1741;

IEEE Std 1547™; IEEE Std 1547.1™; IEEE Std 1547.2™;

ABNT NBR 16149; ABNT NBR 16150;

Ordinance INMETRO no 004, Ordinance INMETRO no 357;

IEC 62040-1; EN 62040-1; AS/NZS 3100; AS/NZS 4777.1;

AS/NZS 4777.2; EN 61727; EN 62116; Provincial

Electricity Authority’s Regulation on the Power Network

System Interconnection Code; Grid-connected Inverter

Regulation Metropolitan Electricity Authority; FGW TR3;

FGW TR4; DIN V VDE V 0124-100;

DIN V VDE V 0126-1-1; DIN V VDE V 0126-1-1/A1;

RD 413; EN 61683; NRS 097-2-3;

ÖVE/ÖNORM E 8001-4-712/A1; UTE-C15-712-2;

XP C15-712-3; BS EN 50438; EN 50438/IS1;

CLC/TS 50549-1; CLC/TS 50549-2; UL 1778;

P.O. 12.2; P.O. 12.3; PVVC Revision 9; PVVC Revision 10;

EN 50530; EN 50530/A1; DIN IEC 62891; IEC/TS 62910;

DEWA

Battery Testing

IEC 62133; EN 62133; IEC 61960; EN 61960; IEC 62620;

IEC 62133-1:2017; EN 62133-1:2017; IEC 62133-2:2017;

EN 62133-2:2017; Certification Requirements for Battery

System Compliance to IEEE 1625;

Certification Requirements for Battery System Compliance

to IEEE 1725; IEC 62281; IEC/EN 61951-1;

IEC/EN 61951-2; UL 2056; IEC 62619;

GB/T 28164; IEEE 1625; IEEE 1725; UN 38.3;

UL 1642; UL 2054; CNS 15364;

Japan DEN-AN Ordinance Article 1 Attached Table 9;

IEC/EN 60086-1; IEC/EN 60086-2; IEC/EN 60086-3;

IEC/EN 60086-4; IEC/EN 60086-5

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 5 of 10

Test Technology:

Test Method(s):

Product Safety

(Excluding Ionizing Radiation, CRT

Tests, Laser Radiation, Hot Flaming

Oil, Test after UV Exposure on

Material, Ultrasonic Pressure)

EN 60950-1; EN 60065; EN 62109-1;

EN 62109-2; EN 50438;

IEC 60950-1; IEC 60065; IEC 62109-1; IEC 62109-2;

IEC 62103; IEC 62368-1 (2010); EN/IEC 62368-1 (2014);

UL 60950-1; UL 60065; UL 60950-23;

UL 1012; UL 1310; UL 62368-1;

CSA C22.2 No. 60950-1-07; CSA C22.2 No. 60065-03;

CSA C22.2 No. 60950-23; CSA C22.2 No. 107.1;

CSA C22.2 No. 223; CSA C22.2 No. 62368-1;

CNS 14336; CNS 14408;

ENEL Guide 2009 / 2010;

AS 4777.1; AS 4777.2; AS 4777.3;

AS/NZS 60950.1; AS/NZS 60065 (2003);

J 60950-1; J 60065;

C10-11; CNCACTS 0004;

UTE-C15-712-1;

VDE_0126-1-1; RD_1663; G59 / G83; GB 4943; GB 8898;

IEC 62040; IEC/EN 61558-1; IEC/EN 61558-2-6;

IEC/EN 61558-2-7; IEC/EN 61558-2-16; IEC/EN 60335-1;

IEC/EN 60335-2-29; IEC/EN 61347-1; IEC/EN 61347-2-13;

AS/NZS 61558-1; AS/NZS 61558-2; AS/NZS 61558-2-7;

AS/NZS 61558-2-16;

IEC 62040-1+AMD1; EN 62040-1/A1

EPA ENERGY STAR Testing

Water Coolers ENERGY STAR Program Requirements for Water Coolers

(ver 2.0);

ENERGY STAR Test Method for Water Coolers

(May 2013)

Audio/Video Equipment ENERGY STAR Program Requirements for Audio/Video

(ver 3.0);

ENERGY STAR Test Method for Audio/Video (July 2012);

IEC/EN 62087

Set Top Boxes ENERGY STAR Program Requirements for Set-top Boxes

(ver 5.1);

CEA-2043 (2013)

Telephony (analog only) ENERGY STAR Program Requirements for Telephony

(ver 3.0);

ENERGY STAR Test Method for Telephony (Nov 2013)

Televisions ENERGY STAR Program Requirements for Televisions

(ver 7.0);

CEA 2037-A

Computers ENERGY STAR Program Requirements for Computers

(ver 6.1);

ENERGY STAR Test Method for Computers (Mar 2016)

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 6 of 10

Test Technology:

Test Method(s):

EPA ENERGY STAR Testing (Cont’d)

Displays ENERGY STAR Program Requirements for Displays

(ver 7.1);

ENERGY STAR Test Method for Determining Displays

Energy (Sept. 2015)

Enterprise Servers ENERGY STAR Program Requirements for Computer

Servers (ver 2.1);

ENERGY STAR Test Method for Computer Servers

(April 2016);

Standard Performance Evaluation Corporation (SPEC) most

Current Server Efficiency Rating Tool (SERT)

Imaging Equipment

ENERGY STAR Program Requirements for Imaging

Equipment (ver 2.0);

ENERGY STAR Imaging Equipment Test Method

(Sept. 2014)

Uninterruptable Power Supplies ENERGY STAR Program Requirements for Uninterruptible

Power Supplies (UPSs) (ver 1.1);

ENERGY STAR Test Method for Uninterruptible Power

Supplies (May 2012)

Energy Efficiency Tests EN 50564 Electrical and Electronic Household and Office

Equipment–Measurement of Low Power Consumption;

EN 5056 –External A.C.–A.C. and A.C.–D.C. Power

Supplies–Determination of No-load Power and Average

Efficiency of Active Modes;

EN 62087 Methods of Measurement for the Power

Consumption of Audio, Video, and Related Equipment;

AS/NZS 4665.1; AS/NZS 4665.2

Canada Energy Efficiency Regulations

External Single Voltage Power

Supply

External Power Supplies Final Bulletin on Developing the

Standard, October 2011 (using CSA-C381.1-08)

Audio/Video Equipment Standby Power Consumption Final Bulletin on Amending

the Standard, October 2011 (using CAN/CSA-C62301:2007

and IEC 62087:2008)

1 This accreditation covers testing performed at the main laboratory listed above, and the satellite

laboratory listed below:

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 7 of 10

Zone A, Floor 1, Building 2

Wan Ye Long Technology Park

South Side of Zhoushi Road, Bao’an District Shenzhen, Guangdong, 518108, People’s Republic of China

Test Technology:

Test Method(s):

Emissions – Unintentional Radiators

Radiated & Conducted

(3m semi-anechoic chamber,

up to 40 GHz)

CFR 47, FCC Part 15B (using ANSI C63.4:2014);

CFR 47, FCC Part 18 (using MP-5:1986);

ICES-001, ICES-003; ICES-005;

CISPR 11; EN 55011; AS/NZS CISPR 11;

CISPR 13; EN 55013; AS/NZS CISPR 13;

CISPR 14-1; EN 55014-1; AS/NZS CISPR 14.1;

CISPR 15; EN 55015; AS/NZS CISPR 15;

CISPR 22; EN 55022; AS/NZS CISPR 22;

CISPR 32; EN 55032; AS/NZS CISPR 32;

CNS 13083; CNS 13438 (up to 6 GHz);

CNS 13439; CNS 13783-1;

J 55013; J 55014-1; J 55015; J 55022; J 55032;

GB 4343.1; GB 824; GB 13837; GB 17743;

GB 9254; GB/T 9383; GB/T 18595;

GR 1089

Emissions – Intentional Radiators

Radiated & Conducted

(3m semi-anechoic chamber,

up to 40 GHz)

CFR 47, FCC Part 15 Subpart C (using ANSI C63.10:2013);

CFR 47, FCC Part 15 Subpart E with DFS

(using ANSI C63.10:2013);

CFR 47, FCC Part 15 Subpart E (using ANSI C63.10:2013);

CFR 47, FCC Parts 22 (cellular), 24, 25 (non-microwave),

27 (ANSI/TIA-603-D & TIA-102.CAAA-D);

Parts 22 (non-cellular), 90 (non-microwave), 95, 97, and

101 (non-microwave);

ANSI/TIA-603-D; ANSI C63.26;

ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015;

RSS-102; RSS-119; RSS-130; RSS-132; RSS-133; RSS-137;

RSS-139; RSS-199; RSS-210; RSS-216; RSS-247; RSS-310;

RSS-GEN;

EN 300 220-1; EN 300 220-2; EN 300 220-3-1;

EN 300 220-3-2; EN 300 220-4;

EN 300 330; EN 300 440; EN 300 386; EN 300 328;

EN 301 893; EN 303 345, EN 303 413;

IMDA TS SRD;

ARIB STD-T66; ARIB STD-T71; ARIB RCR STD-33;

AS/NZS 4268; AS/NZS 4771

Harmonic Current AS/NZS 61000.3.2; EN 61000-3-2; GB 17625.1;

IEC 61000-3-2; IEC/EN 61000-3-12; GB/Z 17625.6

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 8 of 10

Test Technology:

Test Method(s):

Voltage Changes,

Voltage Fluctuations, and Flicker

AS/NZS 61000.3.3; EN 61000-3-3; GB 17625.2;

IEC 61000-3-3; IEC/EN 61000-3-11; GB/Z 17625.3

Immunity

Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2; GB/T 17626.2;

AS/NZS 61000.4.2; CNS 14676-2

Radiated Immunity

(up to 6GHz, 3V/m)

IEC 61000-4-3; EN 61000-4-3; GB/T 17626.3;

AS/NZS 61000.4.3; CNS 14676-3

Electrical Fast Transient IEC 61000-4-4; EN 61000-4-4; GB/T 17626.4;

CNS 14676-4

Surge IEC 61000-4-5; EN 61000-4-5; GB/T 17626.5;

AS/NZS 61000.4.5; CNS 14676-5

Conducted Immunity IEC 61000-4-6; EN 61000-4-6; GB/T 17626.6;

AS/NZS 61000.4.6; CNS 14676-6

Voltage Dips and Short Interrupts IEC 61000-4-11; EN 61000-4-11; GB/T 17626.11;

AS/NZS 61000.4.11; CNS 14676-11

Generic Standards, Product Family

Standards and Industry Specific

Standards

IEC 61000-6-1; EN 61000-6-1; GB 17799.1;

IEC 61000-6-2; EN 61000-6-2; GB 17799.2;

IEC 61000-6-3; EN 61000-6-3; GB 17799.3;

IEC 61000-6-4; EN 61000-6-4; GB 17799.4;

CISPR 24; EN 55024; GB/T 17618;

CISPR 14-2; EN 55014-2; GB 4343.2;

IEC 61547; EN 61547; GB/T 18595;

EN 50130-4; EN 50412-2-1;

CISPR 35; EN 55035;

EN 301 489-1; EN 301 489-3; EN 301 489-17;

EN 301 489-19;

IEC 62920

Radio Communication

(excluding protocol testing)

EN 301 511; EN 301 908-1; EN 301 908-2; EN 301908-13

Telecom

AS/CA S002; AS/CA S003.1;

AS/CA S003.2; AS/CA S003.3;

AS/ACIF S016; AS/ACIF S041.1; AS/ACIF S041.2;

AS/CA S042.1; AS/ACIF S042.3; AS/CA S042.4;

AS/ACIF S043.1; AS/ACIF S043.2;

CS-03 Part I; CS-03 Part II; CS-03 Part VI; CS-03 Part VIII;

TBR 004; TBR 012; TBR 013; TBR 015; TBR 017;

ETSI ES 203 021-1; ETSI ES 203 021-2;

ETSI ES 203 021-3;

ETSI TS 101 270-1; ETSI TS 101 388;

ETSI TS 103 388; ETSI TS 105 388;

TIA-968-B; TIA-968-B-1; FCC Part 68; TIA-968-B-2;

TIA-968-B-3; ANSI/TIA/EIA-464-C; TIA-464-C-1;

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 9 of 10

Test Technology:

Test Method(s):

Telecom (cont.) TIA-1096-A; TIA-TSB-31-D; TIA-TSB-31-D-1;

HKCA 2011; HKCA 2017;

TU-T-G.703; ITU-T-G.823

JATE Blue Book, Green Book;

Ordinance Concerning Terminal Facilities etc.

(Ministerial Ordinance of the Ministry of Posts and

Telecommunications No. 31 of April 1, 1985 as amended

last by the Ministerial Ordinance of the Ministry of

Public Management, Home Affairs, Posts and

Telecommunications No. 44 of March 22, 2004)

Types of products that the laboratory tests:

Information Technology Equipment (ITE); Household Appliances, Electric Tools, and Similar Apparatus;

Sound and Television Broadcast Receivers and Associated Equipment; Electrical Lighting and Similar

Equipment; Industrial, Scientific, and Medical (ISM) Equipment

2 A2LA provides accreditation to the U.S. EPA’s Conditions and Criteria for Recognition of Laboratories

for the ENERGY STAR Program by verifying an organization’s compliance to A2LA document R222 -

Specific Requirements - EPA ENERGY STAR Accreditation Program and to the related test methods

listed above.

Accreditation by A2LA does not infer Recognition by the EPA for ENERGY STAR testing. Please verify

this organization’s recognition status by using the EPA’s searchable database, located at

http://www.energystar.gov/index.cfm?fuseaction=recognized_bodies_list.show_RCB_search_form

Testing Activities Performed in Support of FCC Declaration of Conformity and Certification in

Accordance with 47 Code of Federal Regulations and FCC KDB 974614, Appendix A, Table A.1 3:

Rule Subpart/Technology:

Test Method: Maximum

Frequency (MHz):

Unintentional Radiators

Part 15B ANSI C63.4:2014

40000

Industrial, Scientific, and Medical Equipment

Part 18

FCC MP-5:1986 40000

Intentional Radiators

Part 15C

ANSI C63.10:2013 40000

Unlicensed Personal Communication

Systems Devices

Part 15D

ANSI C63.17:2013 40000

U-NII without DFS Intentional Radiators

Part 15E

ANSI C63.10:2013 40000

U-NII with DFS Intentional Radiators

Part 15E

FCC KDB 905462 D02 (v02) 40000

(A2LA Cert. No. 2951.01) Revised 09/28/2018 Page 10 of 10

Testing Activities Performed in Support of FCC Declaration of Conformity and Certification in

Accordance with 47 Code of Federal Regulations and FCC KDB 974614, Appendix A, Table A.1 3:

Rule Subpart/Technology:

Test Method: Maximum

Frequency (MHz):

UWB Intentional Radiators

Part 15F

ANSI C63.10:2013 40000

BPL Intentional Radiators

Part 15G

ANSI C63.10:2013 40000

White Space Device Intentional Radiators

Part 15H

ANSI C63.10:2013 40000

Commercial Mobile Services (FCC Licensed

Radio Service Equipment)

Parts 22 (cellular), 24, 25 (non-microwave),

and 27

ANSI/TIA-603-D;

TIA-102.CAAA-D

40000

General Mobile Radio Services (FCC

Licensed Radio Service Equipment)

Parts 22 (non-cellular), 90 (non-microwave),

95, 97, and 101 (non-microwave)

ANSI/TIA-603-D;

TIA-102.CAAA-D

40000

Citizens Broadband Radio Services (FCC

Licensed Radio Service Equipment)

Part 96

ANSI/TIA-603-D;

TIA-102.CAAA-D

40000

Microwave and Millimeter Bands Radio

Services

Parts 25, 74, 90 (90Y, 90Z, DSRC), and 101

ANSI/TIA-603-D;

TIA-102.CAAA-D

40000

Broadcast Radio Services

Parts 73 and 74 (non-microwave)

ANSI/TIA-603-D;

TIA-102.CAAA-D

40000

3Accreditation does not imply acceptance to the FCC equipment authorization program. Please see the

FCC website (https://apps.fcc.gov/oetcf/eas/) for a listing of FCC approved laboratories.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.

Accredited Laboratory

A2LA has accredited

BUREAU VERITAS SHENZHEN CO., LTD.

DONGGUAN BRANCH Dongguan City, Guangdong, People’s Republic of China

for technical competence in the field of

Electrical Testing

This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005

General requirements for the competence of testing and calibration laboratories. This laboratory also meets the A2LA

R222 – Specific Requirements – EPA ENERGY STAR Accreditation Program. This accreditation demonstrates technical

competence for a defined scope and the operation of a laboratory quality management system

(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).

Presented this 30th day of April 2018.

_______________________

President and CEO

For the Accreditation Council

Certificate Number 2951.01

Valid to February 29, 2020

For the tests or types of tests to which this accreditation applies, please refer to the laboratory’s «field» Scope of Accreditation.