Buildings and infrastructures Energy savings and performance · •Reduced need for...
Transcript of Buildings and infrastructures Energy savings and performance · •Reduced need for...
![Page 1: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/1.jpg)
Buildings and infrastructures
Energy savings andperformancefor your pumps and fans
Altivar 61Variable speed drive with variable torque for 3-phase asynchronous and synchronous motors0.37 to 2400 kW - Power supply up to 690 V
![Page 2: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/2.jpg)
Flexible High-performance
CommunicativeRugged
Exceptional versatility fromthe smallest application to thehighest power rating
Better communication • Connectivity to all fieldbuses (integrated Modbus and CANopen)• Multi-language graphic display terminal
More flexible• Option cards: programmable I/O• Controller Inside card: openness to a distributed architecture
More powerful• Multi-pump management• Saves energy• Optimises automation solutions with its seamless integration into the architecture• Suitable for a wide range of power ratings (0.37 to 2400 kW)• Integrated safety function
More rugged in harsh environments• 3C2 reinforced version, standard IEC 721-3-3(gas, liquids), IP20/IP54• Versions with water cooling• IP54/IP55 wall-mounted or floor-standing enclosures available• Complies with ATEX safety standards (explosive environments)
![Page 3: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/3.jpg)
70%* energy savings on fans50%* on pumps
Designed to be eco-friendly:•Optimises energy consumption according to the load applied to the machine•Reduces noise pollution• Avoids interference on the electrical supply: reduction of current harmonics (optional chokes, passive filters, Active Front End (AFE), etc.)•Eco-designed product compliant with environmental standard ISO 14040•Reduced need for air conditioning
* Depending on the application
Cooling tower fan system Multi-pump solution
Air purification and smoke extraction system in a road tunnel
Eco-friendly:• Altivar 61 is RoHS compliant• 90% recyclable materials
![Page 4: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/4.jpg)
A complete expandable product
More economical•Asingleproductforincreasedperformance•Lesswiring•Protectsyourinstallations•Reducesmaintenancecosts
More expandable•Adaptstoyourmachines•Optimalintegration•Side-by-sidemountingcapability•Multidropconnectionbetweengraphicdisplay terminalandanumberofdrives•Suppliedwitheithera7-segmentdisplayterminal ortheremotegraphicdisplayterminal
Safer thanks to multiple protection•Ofthemotor: -thermalprotection(PTCprobesorintegrated electronicthermaloverloadrelay) -overcurrentprotection -mechanicalprotection:preventsshocksand eliminatesresonance•Ofthemachine: -PowerRemovalsafetyfunction•Ofthedrive: -self-protectionintheeventofoverheating -hardwareandsoftwarecurrentlimit -resistanttoharshoperatingenvironments -drivehasATEXcertificationsoitcancontrol themotorinexplosiveatmospheres
![Page 5: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/5.jpg)
Modular design for greater versatility
A wide range of power ratings •1AC200to240V:Altivar61from0.37to5.5kW•3AC200to240V:Altivar61from0.75to90kW•3AC380to480V:Altivar61from0.75to630kW•3AC500to690V:Altivar61from2.2to800kW•3AC380to480V:Altivar61Q(watercooled)from110to630kW•3AC500to690V:Altivar61Q(watercooled)from132to800kW•3AC380to690V:Altivar61Plusfrom90to2400kW
A wide range of functions •More energy savings: -Quadraticratioforcontroladaptedtopumpsandfans•More economical: -IntegratedEMCfilter*,simplifiedinstallationandbringing intoconformity -Upto200metresofcablewithoutamotorchoke•Improved safety and efficiency for your network: -Reductionofcurrentharmonicsviaasolutionintegrated intheproduct•More openness: specificI/Oforapplicationfunctions•Better continuity of service: thedrivecanbecontrolled separatelyin24VDC• Greater flexibility: 3typesofcontrol -Automaticforgreaterautonomyandbetterperformance -Semi-automatictostayincontroloftheapplicationatalltimes -Manualtomakesetupandmaintenanceeasier
A wide choice of option cardsBetter performance:•Multi-pumpcardforcontrollingupto5pumps: -compensatesforlossofpressure -offersvariedfunctions:closedloopcontrol(PID),sleep/wake-upfunction,etc. -reducesinstallationcosts -prolongsthelifeofyourinstallation:reductionofpressureshocks(pressuresurges) -manageshowlongeachpumpworksfor -reducesenergyconsumption•Communicationcards(ProfiBusDP,ModbusTCP,DaisyChainandPlus,DeviceNet, BACnet,LonWorks,Ethernet,APOGEE,METASYS,etc.)•Programmablecontrollercards•I/Oextensioncards•Encoderinterfacecards
*C1,C2,C3dependingonthemodel
More than 150 specific applications available
Altivar61Q:improvedrobustnesswithwatercooling• Efficient cooling system: 85 to 100% of waste heat is dissipated into the drive water-cooling system• Reduced need for air-conditioning• Prolonged maintenance-free operational life• Excellent protection against corrosion due to stainless steel cooling pipes
200 4000
0
0 5.5kW
2400kW
800kW
220020001900180014001200
Altivar 61 Plus - Three-phase
Altivar 61 - Single-phase
Altivar 61 - Three-phase
1000900800
400 V 90 to 1.400 kW
200 V 0.75 to 90
500 V 90 to 1.800 kW
400 V 0.75 to 630
690 V 110 to 2.400 kW
690 V 2.2 to 800
400 V 110 to 630 (water cooled)
690 V 132 to 800 (water cooled)
200 V 0.37 to 5.5
![Page 6: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/6.jpg)
Advanced functions for an effectiveresponse to every type of application
Increased safety:aeration and smoke extraction
•Fire function (forceddriveoperation)with: -faultinhibition -selectionofrotationdirectionand thespeedreference• For high-inertia applications: -highbrakingcapacityupto1MW -energyregenerationwithActiveFrontEnd (AFE) -catchontheflybyspeedsearching regardlessofthedirectionofrotation• Regulation of CO2 by integrated PIregulator
Increased comfort:disturbance-free ventilation•Reduction in noise pollution causedbyfanoperation(actiononthe motorandthemachine): -skipfrequencies -switchingfrequencycanbeadjusted duringoperation -“whitenoise”randomfrequency•Energy savingslinkedtoimprovement inapplicationperformance
Optimal fluid management
•Network availability: managementby integratedmulti-pumpcard• Constant pressure: pumpstarting onrequest• Reduced maintenance costs: equitabledistributionofpumpuse• Simple operation: -detectionofoverloadsandunderloads -flowlimitation -sleep/wake-upfunction(flowdetection) -diagnostics(brokenbelt,lossofpump priming,phaseloss,powersupplyfault, etc.) -tests -etc.
Makesureyournetworkiswatertight40% of distributed wateris lost through leaks. Theintegrated multi-pumpcard detects and flags upfluid losses in distributionnetworks.
Saveenergywith pressure regulation,the pumps operateon demand.
![Page 7: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/7.jpg)
Design
•SoMachineprogrammingsoftware -Applicationprojectconfiguration management
Setup
•SoMovesetupsoftware -DirectconnectionusingaUSB-RJ45 cable -CommonplatformforAltivar&Lexium -Reductionofdesignandinstallationcosts
Configuration
•MultiLoader -Storageandduplicationofconfigurations•SimpleLoader -Duplicationofconfigurations
Graphical user interface
•Multilingualremotegraphicdisplayterminal -Driveconfiguration,adjustment, diagnosticsandmaintenance -4configurationscanbebackedup -Choiceof8languagesasstandard andmorethan20othersavailablefor download
Remote communication
•SoMoveMobileapplicationfor mobilephonesEfficiency•Downloading,editingandsendingof configurations•Driveadjustmentandmaintenance•Configurationfilescanbesentandreceived locallyorremotelyinamatterofseconds Safety•Remotesupervisionandadjustmentof themachine•Nomorephysicalorsafetyconstraints foraccessingthemachinesthanksto theBluetoothconnection•Backupofchangesorreinstallation ofsavedconfigurations
Simplicity•Comfortableworkingposition(access toequipmentwhichisdifficulttoaccess manually)•User-friendlydialoguefunctionswith SoMoveMobile™•Contextualnavigationthroughthemenus•SharingofconfigurationfilesviaMMSor e-mail
More than 20 languages available
Tools that focus on your applications:dialogue and user-friendlinessCalling all designers, installers, distributors, after-sales technicians,etc: minimise your installation and programming times and cut yourcosts, with the common platform of tools for the Altivar and Lexiumranges.
![Page 8: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/8.jpg)
Altivar 61Integrated and integrable protection
IP54 product solution •0.75to90kW/380Vto480V•Enclosedproduct•EMCC1orC2•WithorwithoutVarioswitch
Altivar 61 PlusIP23/IP54/IP55 ready-assembledenclosure •90to2400kW/380to690V•CompactversionwithIP23andIP54protection•FullyclosedenclosureIP55withexternalwatercooling•Configurableonrequest•Enclosuretestedatfullload
Preassembled kit in IP54enclosure•110kWto800kW/380Vto480V•Enclosuresuppliedinkitform•Costandtimesavings (thermaltestsandIP54certified)•Simpleassembly
Altivar 61 PlusSA IP54 ready-assembledenclosure•90to2400kW/380to690V•Separateaircoolingsystem•Unitsuppliedreadytoconnect•Excellentresistancetoharshenvironments
![Page 9: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/9.jpg)
When technology helps save energy
Variable speeddrive No. 1
Variable speeddrive No. 2
Variable speeddrive No. 3
Communicationnetworks
Electrical networks
PLCAltivar Active
Front End
AFE AFE
Human-machinedialogue
Communication cards:Fipio, Ethernet,Modbus Plus, PROFIBUS DP, DeviceNet, Uni-Telway, INTERBUS,LONWorks, MetasysN2, Apogee P1, BACnet, for connection to the majority ofcommercially-available communication networks.
More user-friendly and more communicative•FastdirectdataexchangeswithModbusandCANopenasstandard: -High-speeddataexchange -Directconnectiontoindustrialcontrolsystems
Improved dynamics and energy savings with Active FrontEnd (AFE)•ActiveFrontEndisanoptionwhichallowsthedrivetoreducethetotalcurrentharmonic distortion(THDI)tolessthan4%•AltivarActiveFrontEndevenworkswithweakorunstablenetworks
![Page 10: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/10.jpg)
Quality is our watchword, throughout the world
Products compliant with international standards•UL,cUL,CSA,CE,C-Tick,GOST•ATEX(No.94/9/ECzones1,21,2,22)•Marine(DNV,ABS,BV,LRos,RMSos,KRS),SemiF47•EMC(No.2004/108/ECmodificationofdirectiveNo.89/336/EEC•Etc.(seecatalogue)
Sustainable developmentRecognisedforitscommitmenttosustainabledevelopment,SchneiderElectrichasbeenselectedtotakepartinthe5mainbenchmarkglobalindexes:•DowJonesSustainabilitySTOXXIndex•DowJonesSustainabilityWordIndex•ASPIEurozone(AdvancedSustainablePerformanceIndex)•EthibelSustainabilityIndex(ESI)ExcellenceEurope•EthibelSustainabilityIndex(ESI)ExcellenceGlobal
The international presence of a major group, with dedicated Service teams
1000experts dedicated
to consultancyand project
management
1000expert partners
150service centres
50customer training
centres
More than
6000experts at
your service
![Page 11: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/11.jpg)
Make the most of your energy!
![Page 12: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against](https://reader036.fdocuments.in/reader036/viewer/2022081409/6079938ab4d27109371046a6/html5/thumbnails/12.jpg)
ART: 837368 DIA
2ED
1090
801E
N
Schneider Electric Industries SAS
Head office:35 rue Joseph Monier CS 3032392506 Rueil-Malmaison CedexFrance
www.schneider-electric.com
Due to possible changes in standards and equipment, the featuresdescribed in this document in the form of text and images are subject toconfirmation by Schneider Electric.
Designed and created by: GavrinisPhotos: Schneider ElectricPrinting:
11/2010