Buildings and infrastructures Energy savings and performance · •Reduced need for...

12
Buildings and infrastructures Energy savings and performance for your pumps and fans Altivar 61 Variable speed drive with variable torque for 3-phase asynchronous and synchronous motors 0.37 to 2400 kW - Power supply up to 690 V

Transcript of Buildings and infrastructures Energy savings and performance · •Reduced need for...

Page 1: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

Buildings and infrastructures

Energy savings andperformancefor your pumps and fans

Altivar 61Variable speed drive with variable torque for 3-phase asynchronous and synchronous motors0.37 to 2400 kW - Power supply up to 690 V

Page 2: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

Flexible High-performance

CommunicativeRugged

Exceptional versatility fromthe smallest application to thehighest power rating

Better communication • Connectivity to all fieldbuses (integrated Modbus and CANopen)• Multi-language graphic display terminal

More flexible• Option cards: programmable I/O• Controller Inside card: openness to a distributed architecture

More powerful• Multi-pump management• Saves energy• Optimises automation solutions with its seamless integration into the architecture• Suitable for a wide range of power ratings (0.37 to 2400 kW)• Integrated safety function

More rugged in harsh environments• 3C2 reinforced version, standard IEC 721-3-3(gas, liquids), IP20/IP54• Versions with water cooling• IP54/IP55 wall-mounted or floor-standing enclosures available• Complies with ATEX safety standards (explosive environments)

Page 3: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

70%* energy savings on fans50%* on pumps

Designed to be eco-friendly:•Optimises energy consumption according to the load applied to the machine•Reduces noise pollution• Avoids interference on the electrical supply: reduction of current harmonics (optional chokes, passive filters, Active Front End (AFE), etc.)•Eco-designed product compliant with environmental standard ISO 14040•Reduced need for air conditioning

* Depending on the application

Cooling tower fan system Multi-pump solution

Air purification and smoke extraction system in a road tunnel

Eco-friendly:• Altivar 61 is RoHS compliant• 90% recyclable materials

Page 4: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

A complete expandable product

More economical•Asingleproductforincreasedperformance•Lesswiring•Protectsyourinstallations•Reducesmaintenancecosts

More expandable•Adaptstoyourmachines•Optimalintegration•Side-by-sidemountingcapability•Multidropconnectionbetweengraphicdisplay terminalandanumberofdrives•Suppliedwitheithera7-segmentdisplayterminal ortheremotegraphicdisplayterminal

Safer thanks to multiple protection•Ofthemotor: -thermalprotection(PTCprobesorintegrated electronicthermaloverloadrelay) -overcurrentprotection -mechanicalprotection:preventsshocksand eliminatesresonance•Ofthemachine: -PowerRemovalsafetyfunction•Ofthedrive: -self-protectionintheeventofoverheating -hardwareandsoftwarecurrentlimit -resistanttoharshoperatingenvironments -drivehasATEXcertificationsoitcancontrol themotorinexplosiveatmospheres

Page 5: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

Modular design for greater versatility

A wide range of power ratings •1AC200to240V:Altivar61from0.37to5.5kW•3AC200to240V:Altivar61from0.75to90kW•3AC380to480V:Altivar61from0.75to630kW•3AC500to690V:Altivar61from2.2to800kW•3AC380to480V:Altivar61Q(watercooled)from110to630kW•3AC500to690V:Altivar61Q(watercooled)from132to800kW•3AC380to690V:Altivar61Plusfrom90to2400kW

A wide range of functions •More energy savings: -Quadraticratioforcontroladaptedtopumpsandfans•More economical: -IntegratedEMCfilter*,simplifiedinstallationandbringing intoconformity -Upto200metresofcablewithoutamotorchoke•Improved safety and efficiency for your network: -Reductionofcurrentharmonicsviaasolutionintegrated intheproduct•More openness: specificI/Oforapplicationfunctions•Better continuity of service: thedrivecanbecontrolled separatelyin24VDC• Greater flexibility: 3typesofcontrol -Automaticforgreaterautonomyandbetterperformance -Semi-automatictostayincontroloftheapplicationatalltimes -Manualtomakesetupandmaintenanceeasier

A wide choice of option cardsBetter performance:•Multi-pumpcardforcontrollingupto5pumps: -compensatesforlossofpressure -offersvariedfunctions:closedloopcontrol(PID),sleep/wake-upfunction,etc. -reducesinstallationcosts -prolongsthelifeofyourinstallation:reductionofpressureshocks(pressuresurges) -manageshowlongeachpumpworksfor -reducesenergyconsumption•Communicationcards(ProfiBusDP,ModbusTCP,DaisyChainandPlus,DeviceNet, BACnet,LonWorks,Ethernet,APOGEE,METASYS,etc.)•Programmablecontrollercards•I/Oextensioncards•Encoderinterfacecards

*C1,C2,C3dependingonthemodel

More than 150 specific applications available

Altivar61Q:improvedrobustnesswithwatercooling• Efficient cooling system: 85 to 100% of waste heat is dissipated into the drive water-cooling system• Reduced need for air-conditioning• Prolonged maintenance-free operational life• Excellent protection against corrosion due to stainless steel cooling pipes

200 4000

0

0 5.5kW

2400kW

800kW

220020001900180014001200

Altivar 61 Plus - Three-phase

Altivar 61 - Single-phase

Altivar 61 - Three-phase

1000900800

400 V 90 to 1.400 kW

200 V 0.75 to 90

500 V 90 to 1.800 kW

400 V 0.75 to 630

690 V 110 to 2.400 kW

690 V 2.2 to 800

400 V 110 to 630 (water cooled)

690 V 132 to 800 (water cooled)

200 V 0.37 to 5.5

Page 6: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

Advanced functions for an effectiveresponse to every type of application

Increased safety:aeration and smoke extraction

•Fire function (forceddriveoperation)with: -faultinhibition -selectionofrotationdirectionand thespeedreference• For high-inertia applications: -highbrakingcapacityupto1MW -energyregenerationwithActiveFrontEnd (AFE) -catchontheflybyspeedsearching regardlessofthedirectionofrotation• Regulation of CO2 by integrated PIregulator

Increased comfort:disturbance-free ventilation•Reduction in noise pollution causedbyfanoperation(actiononthe motorandthemachine): -skipfrequencies -switchingfrequencycanbeadjusted duringoperation -“whitenoise”randomfrequency•Energy savingslinkedtoimprovement inapplicationperformance

Optimal fluid management

•Network availability: managementby integratedmulti-pumpcard• Constant pressure: pumpstarting onrequest• Reduced maintenance costs: equitabledistributionofpumpuse• Simple operation: -detectionofoverloadsandunderloads -flowlimitation -sleep/wake-upfunction(flowdetection) -diagnostics(brokenbelt,lossofpump priming,phaseloss,powersupplyfault, etc.) -tests -etc.

Makesureyournetworkiswatertight40% of distributed wateris lost through leaks. Theintegrated multi-pumpcard detects and flags upfluid losses in distributionnetworks.

Saveenergywith pressure regulation,the pumps operateon demand.

Page 7: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

Design

•SoMachineprogrammingsoftware -Applicationprojectconfiguration management

Setup

•SoMovesetupsoftware -DirectconnectionusingaUSB-RJ45 cable -CommonplatformforAltivar&Lexium -Reductionofdesignandinstallationcosts

Configuration

•MultiLoader -Storageandduplicationofconfigurations•SimpleLoader -Duplicationofconfigurations

Graphical user interface

•Multilingualremotegraphicdisplayterminal -Driveconfiguration,adjustment, diagnosticsandmaintenance -4configurationscanbebackedup -Choiceof8languagesasstandard andmorethan20othersavailablefor download

Remote communication

•SoMoveMobileapplicationfor mobilephonesEfficiency•Downloading,editingandsendingof configurations•Driveadjustmentandmaintenance•Configurationfilescanbesentandreceived locallyorremotelyinamatterofseconds Safety•Remotesupervisionandadjustmentof themachine•Nomorephysicalorsafetyconstraints foraccessingthemachinesthanksto theBluetoothconnection•Backupofchangesorreinstallation ofsavedconfigurations

Simplicity•Comfortableworkingposition(access toequipmentwhichisdifficulttoaccess manually)•User-friendlydialoguefunctionswith SoMoveMobile™•Contextualnavigationthroughthemenus•SharingofconfigurationfilesviaMMSor e-mail

More than 20 languages available

Tools that focus on your applications:dialogue and user-friendlinessCalling all designers, installers, distributors, after-sales technicians,etc: minimise your installation and programming times and cut yourcosts, with the common platform of tools for the Altivar and Lexiumranges.

Page 8: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

Altivar 61Integrated and integrable protection

IP54 product solution •0.75to90kW/380Vto480V•Enclosedproduct•EMCC1orC2•WithorwithoutVarioswitch

Altivar 61 PlusIP23/IP54/IP55 ready-assembledenclosure •90to2400kW/380to690V•CompactversionwithIP23andIP54protection•FullyclosedenclosureIP55withexternalwatercooling•Configurableonrequest•Enclosuretestedatfullload

Preassembled kit in IP54enclosure•110kWto800kW/380Vto480V•Enclosuresuppliedinkitform•Costandtimesavings (thermaltestsandIP54certified)•Simpleassembly

Altivar 61 PlusSA IP54 ready-assembledenclosure•90to2400kW/380to690V•Separateaircoolingsystem•Unitsuppliedreadytoconnect•Excellentresistancetoharshenvironments

Page 9: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

When technology helps save energy

Variable speeddrive No. 1

Variable speeddrive No. 2

Variable speeddrive No. 3

Communicationnetworks

Electrical networks

PLCAltivar Active

Front End

AFE AFE

Human-machinedialogue

Communication cards:Fipio, Ethernet,Modbus Plus, PROFIBUS DP, DeviceNet, Uni-Telway, INTERBUS,LONWorks, MetasysN2, Apogee P1, BACnet, for connection to the majority ofcommercially-available communication networks.

More user-friendly and more communicative•FastdirectdataexchangeswithModbusandCANopenasstandard: -High-speeddataexchange -Directconnectiontoindustrialcontrolsystems

Improved dynamics and energy savings with Active FrontEnd (AFE)•ActiveFrontEndisanoptionwhichallowsthedrivetoreducethetotalcurrentharmonic distortion(THDI)tolessthan4%•AltivarActiveFrontEndevenworkswithweakorunstablenetworks

Page 10: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

Quality is our watchword, throughout the world

Products compliant with international standards•UL,cUL,CSA,CE,C-Tick,GOST•ATEX(No.94/9/ECzones1,21,2,22)•Marine(DNV,ABS,BV,LRos,RMSos,KRS),SemiF47•EMC(No.2004/108/ECmodificationofdirectiveNo.89/336/EEC•Etc.(seecatalogue)

Sustainable developmentRecognisedforitscommitmenttosustainabledevelopment,SchneiderElectrichasbeenselectedtotakepartinthe5mainbenchmarkglobalindexes:•DowJonesSustainabilitySTOXXIndex•DowJonesSustainabilityWordIndex•ASPIEurozone(AdvancedSustainablePerformanceIndex)•EthibelSustainabilityIndex(ESI)ExcellenceEurope•EthibelSustainabilityIndex(ESI)ExcellenceGlobal

The international presence of a major group, with dedicated Service teams

1000experts dedicated

to consultancyand project

management

1000expert partners

150service centres

50customer training

centres

More than

6000experts at

your service

Page 11: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

Make the most of your energy!

Page 12: Buildings and infrastructures Energy savings and performance · •Reduced need for air-conditioning •Prolonged maintenance-free operational life •Excellent protection against

ART: 837368 DIA

2ED

1090

801E

N

Schneider Electric Industries SAS

Head office:35 rue Joseph Monier CS 3032392506 Rueil-Malmaison CedexFrance

www.schneider-electric.com

Due to possible changes in standards and equipment, the featuresdescribed in this document in the form of text and images are subject toconfirmation by Schneider Electric.

Designed and created by: GavrinisPhotos: Schneider ElectricPrinting:

11/2010