BuildingEnvelope ® Table of Contents 1-866-Oldcastle (653-2278) - www.obe.com 1-866-OLDCASTLE (653-2278) www.obe.com 0-FG-5100T-StormMax-TOC February 2017 FG-5100T STORMMAX™ IMPACT RESISTANT THERMAL STOREFRONT / 2-1/2" X 5" / 1-5/16" GLAZING FG-5100T-StormMax-2.5x5-1.3125-glz-Elevation H8320-Head-Horizontal V8320-Perimeter-Vertical-Light-Mullion H8321-Head-Pre-Glazed V8321-Perimeter-Vertical-Heavy-Mullion H8325-Intermediate-Horizontal V8325-Intermediate-Vertical-Light-Mullion H8327-Sill-Horizontal V8326-Intermediate-Vertical-Heavy-Mullion H8328-Sill-Pre-Glazed-Option1 V8327-Expansion-Mullion H8329-Sill-Pre-Glazed-Option2 V8328-Perimeter-Vertical-Light-Mullion H8340-Head-at-Transom V8329-Perimeter-Vertical-Heavy-Mullion H8342-Door-Header-with-Transom V8330-90-OSC H8345-Bottom-Door-Rail-w-Threshold V8331-135-OSC V8340-Vertical-at-Transom-Sidelight V8341-Door-Jamb-at-Sidelight V8345-Meeting-Stiles

Transcript of BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327...

Page 1: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

BuildingEnvelope®

Table of Contents

1-866-Oldcastle (653-2278) - www.obe.com

1-866-OLDCASTLE (653-2278) www.obe.com0-FG-5100T-StormMax-TOC

February 2017

FG-5100T STORMMAX™

IMPACT RESISTANT THERMAL STOREFRONT / 2-1/2" X 5" / 1-5/16" GLAZING

FG-5100T-StormMax-2.5x5-1.3125-glz-Elevation

H8320-Head-Horizontal V8320-Perimeter-Vertical-Light-Mullion

H8321-Head-Pre-Glazed V8321-Perimeter-Vertical-Heavy-Mullion

H8325-Intermediate-Horizontal V8325-Intermediate-Vertical-Light-Mullion

H8327-Sill-Horizontal V8326-Intermediate-Vertical-Heavy-Mullion

H8328-Sill-Pre-Glazed-Option1 V8327-Expansion-Mullion

H8329-Sill-Pre-Glazed-Option2 V8328-Perimeter-Vertical-Light-Mullion

H8340-Head-at-Transom V8329-Perimeter-Vertical-Heavy-Mullion

H8342-Door-Header-with-Transom V8330-90-OSC

H8345-Bottom-Door-Rail-w-Threshold V8331-135-OSC

V8340-Vertical-at-Transom-Sidelight

V8341-Door-Jamb-at-Sidelight

V8345-Meeting-Stiles

Page 2: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

FG-5100T StormMax™

Impact-Resistant Thermal Storefront

2-1/2" X 5" w/ 1-5/16" Glazing

V8329

PERIMETER VERTICAL

V8321

PERIMETER VERTICAL

V8320

HEAVY

MULLION

LIGHT

MULLION

V8328

LIGHT

MULLION

HEAVY

MULLION

V8325

LIGHT

MULLION

HEAVY

MULLION

V8327

EXPANSION

MULLION

V8326

INT. VERTICAL

V8330

V8331

135°

CORNER

90° CORNER

H8340

HEAD @

TRANSOM

H8320

H8321

STANDARD

PRE-GLAZED

OPTION

H8325

INTERMEDIATE

HORIZONTAL

NOTES:

- FOR SPECIFIC PRODUCT APPLICATIONS, CONTACT AN OLDCASTLE

BUILDINGENVELOPE

®

REPRESENTATIVE

- WHEN USED IN FLORIDA, REFER TO STATE OF FLORIDA PRODUCT

APPROVAL OR MIAMI-DADE COUNTY NOTICE OF ACCEPTANCE (NOA)

FOR APPROVED FASTENERS AND SEALANT

H8327

SILL HORIZONTAL

H8328

STANDARD

PRE-GLAZED

OPTION 1

H8329

PRE-GLAZED

OPTION 2

HEAD HORIZONTAL

H8342

DOOR HEADER & TOP

RAIL W/ TRANSOM

V8341

DOOR JAMB

W/ SIDELIGHT

V8340

VERTICAL @

TRANSOM

SIDELIGHT

V8345

MEETING STILES

H8345

BOTTOM DOOR RAIL

W/ THRESHOLD

Page 3: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Head Horizontal - H8320

H8320-Head-HorizontalFebruary 2017

1/4"

2 1/2"

D.L.O

.

5"

FG-5254 HEAD FILLER

FG-5250 HEAD

FG-5185 SPACER GASKET W/

STRUCTURAL SILICONE

1 5/16" INSULATING LAMINATED GLASS

FG-1133 GASKET

ANCHOR BOLT

(BY OTHERS)

SHIM & BACKER

ROD/SEALANT

(BY OTHERS)

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 4: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Head Horizontal - Pre-Glazed - H8321

H8321-Head-Pre-GlazedFebruary 2017

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

5"

2 1

/2

"

1/2

"

D.L

.O

.

FG-5185 SPACER GASKET W/

STRUCTURAL SILICONE

1 5/16" INSULATING LAMINATED GLASS

FG-1133 GASKET

1 11/16"

FG-5253

HEAD

ANCHOR

ANCHOR BOLT

(BY OTHERS)

FS-126

LOCATE (2) ON EACH

SIDE OF MULLION,

SPACED @ 1-1/2" AND

4-1/2" FROM MULLS

SHIM & BACKER

ROD/SEALANT

(BY OTHERS)

5/1

6"

FG-5250 HEAD

Page 5: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Intermediate Horizontal - H8325

H8325-Intermediate-HorizontalFebruary 2017

FG-5214

HORIZONTAL

FG-5185 SPACER GASKET W/

STRUCTURAL SILICONE

1 5/16" INSULATING LAMINATED GLASS

FG-1133 GASKET

FG-5258

GLASS

STOP

5"

2 1

/2

"

FG-5186

SETTING BLOCK

D.L

.O

.D

.L

.O

.

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 6: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Sill Horizontal - H8327

H8327-Sill-HorizontalFebrary 2017

FG-5214

HORIZONTAL

FG-5185 SPACER GASKET W/

STRUCTURAL SILICONE

1 5/16" INSULATING LAMINATED GLASS

FG-1133

GASKET

FG-5258

GLASS

STOP FG-5186

SETTING BLOCK

FG-5260 SUBSILL

ANCHOR BOLT

(BY OTHERS)

1/4

"3

/4

"2

1

/2

"

5"

D.L

.O

.

SHIM & BACKER

ROD/SEALANT

(BY OTHERS)

FS-127

LOCATE (2) ON

EACH SIDE OF

MULLION, SPACED

@ 1-1/2" AND 4-1/2"

FROM MULLS

SILICONE

SEALANT

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 7: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Sill Horizontal - Pre-Glazed Option 1 - H8328

H8328-Sill-Pre-glaze-Option1February 2017

1 5/16" INSULATING LAMINATED GLASS

FG-1133 GASKET

FG-5258

GLASS

STOP

FG-5260 SUBSILL

ANCHOR BOLT

(BY OTHERS)

1/4

"3

/4

"2

1

/2

"

5"

FG-5252 SILL

HORIZONTAL

FG-5259 POCKET

FILLER

FG-5226

SETTING

CHAIR

FG-5186 SETTING BLOCK

FG-5185 SPACER GASKET W/

STRUCTURAL SILICONE

D.L

.O

.

SHIM & BACKER

ROD/SEALANT

(BY OTHERS)

FS-128

LOCATE (2) ON

EACH SIDE OF

MULLION, SPACED

@ 1-1/2" AND 4-1/2"

FROM MULLS

SILICONE

SEALANT

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 8: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Sill Horizontal - Option 2 - H8329

H8329-Sill-Pre-glaze-Option2February 2017

1 5/16" INSULATING LAMINATED GLASS

FG-1133 GASKET

FG-5258

GLASS

STOP

FG-5260 SUBSILL

ANCHOR BOLT

(BY OTHERS)

1/4

"3

/4

"2

1

/2

"

5"

FG-5213 SILL

HORIZONTAL

FG-5226

SETTING

CHAIR

FG-5186 SETTING BLOCK

FG-5185 SPACER GASKET W/

STRUCTURAL SILICONE

D.L

.O

.

SHIM & BACKER

ROD/SEALANT

(BY OTHERS)

FS-127

LOCATE (2) ON

EACH SIDE OF

MULLION, SPACED

@ 1-1/2", 3", 4-1/2" &

6" FROM MULLS

SILICONE

SEALANT

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 9: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Head Horizontal at Transom - H8340

H8340-Head-at-TransomFebruary 2017

FG-5185 SPACER GASKET W/

STRUCTURAL SILICONE

2 1

/2

"1

/4

"D

.L

.O

.

FG-1133

GASKET

1 5/16" INSULATING LAMINATED GLASS

FG-5177

GLASS STOP

FG-5178 HEAD

5"

ANCHOR BOLT

(BY OTHERS)

SHIM & BACKER

ROD/SEALANT

(BY OTHERS)

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 10: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Door Header & Top Rail w/ Transom - H8342

H8342-Door-Header-with-TransomFebruary 2017

5"

2 1

/2

"

FG-5235 DOOR

HEADER

FG-5163

DOOR STOP

D-125 GASKET

D.L

.O

.

HP-17 SETTING

BLOCK

FG-1133

GASKET

1 5/16" INSULATING LAMINATED GLASS

FG-5185 SPACER GASKET W/

STRUCTURAL SILICONE

D-152 GLASS STOP

FS-7 FASTENERS

(TOP AND BOTTOM)

CB-38 CORNER BLOCK

D-38 TOP RAIL

F-5188 SPACE GASKET W/

STRUCTURAL SILICONE

S-83 GLASS STOP

FG-1133 GASKET

3"

SEMS FASTENERS

FS-57 FASTENER

13

/1

6"

D.L

.O

.

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 11: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Bottom Door Rail w/ Threshold - H8345

H8345-Bottom-Door-Rail-with-ThresholdFebruary 2017

S-83 GLASS STOP

FG-1133 GASKET

FG-5188 SPACER GASKET W/

STRUCTURAL SILICONE

D-61 BOTTOM RAIL

CB-61 CORNER BLOCK

TH-57 THRESHOLD

FASTENER BY OTHERS

D-134-2 PANIC STOP

ATTACH W/ FS-56 (#10 X

1/2" PFH B PT)

D-120 DOOR SWEEP

D-118 SWEEP RETAINER

ATTACH W/ FS-2 (#8 X 1/2"

PFH A PT)

FS-7 FASTENERS (#10-16 X 3/4" PFH B PT)

(TOP AND BOTTOM)

1/2

"

11

/1

6"

10

"1

3/1

6"

D.L

.O

.

D-152 GLASS STOP

SEMS FASTENERS

Page 12: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Perimeter Vertical - Light Mullion - V8320

V8320-Perimeter-Vertical-Light-MullionFebruary 2017

5"

1/2" 2 1/2"

FG-5250 JAMB MULLION

FG-5254 FILLER

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

SHIM & BACKER ROD/SEALANT

(BY OTHERS)

FG-1133 GASKET

FG-5949

INTERIOR

GASKET

1 5/16" INSULATING

LAMINATED GLASS

D.L.O.

DRY GLAZED OPTION

Page 13: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Perimeter Vertical - Heavy Mullion - V8321

V8321-Perimeter-Vertical-Heavy-MullionFebruary 2017

1/2" 2 1/2"

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

SHIM & BACKER ROD/SEALANT

(BY OTHERS)

FG-1133 GASKET

1 5/16" INSULATING

LAMINATED GLASS

D.L.O.

FG-5251 MULLION

FG-5254 FILLER

5"

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 14: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Intermediate Vertical - Light Mullion - V8325

V8325-Intermediate-Vertical-Light-MullionFebruary 2017

FG-5250 JAMB MULLION

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

FG-1133 GASKET

1 5/16" INSULATING

LAMINATED GLASS

FG-5217 FILLER

2 1/2"

D.L.O. D.L.O.

5"

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 15: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Intermediate Vertical - Heavy Mullion - V8326

V8326-Intermediate-Vertical-Heavy-MullionFebruary 2017

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

1 5/16" INSULATING

LAMINATED GLASS

2 1/2"

D.L.O. D.L.O.

FG-5217 FILLER

FG-5251 MULLION

FG-1133 GASKET

5"

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 16: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Expansion Mullion - V8327

V8327-Expansion-MullionFebrary 2017

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

1 5/16" INSULATING

LAMINATED GLASS

2 3/4"

D.L.O.D.L.O.

FG-1133 GASKET

5"

FG-5256 MULLION HALF

FG-5257

MULLION HALF

CW-998 GASKET

1/4"

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 17: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Perimeter Vertical - Light Mullion - V8328

V8328-Perimeter-Vertical-Light-MullionFebruary 2017

FG-5250 JAMB MULLION

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

FG-1133 GASKET

1 5/16" INSULATING

LAMINATED GLASS

FG-5217 FILLER

2 1/2"

D.L.O.

5"

1/2"

SHIM & BACKER

ROD/SEALANT

(BY OTHERS)

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 18: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Perimeter Vertical - Heavy Mullion - V8329

V8329-Perimeter-Vertical-Heavy-MullionFebruary 2017

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

FG-1133 GASKET

1 5/16" INSULATING

LAMINATED GLASS

2 1/2"

D.L.O.

5"

1/2"

SHIM & BACKER

ROD/SEALANT

(BY OTHERS)

FG-5251 MULLION

FG-5217 FILLER

Page 19: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

90° Outside Corner - V8330

V8330-90-OSCFebruary 2017

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

FG-1133 GASKET

1 5/16" INSULATING

LAMINATED GLASS

FG-5261 90°

CORNER

MULLION

FG-5255 FILLER

5"

5 1/2"

5 1/2"

FS-125

LOCATE @ 18"

O.C. BOTH SIDES

(STAGGERED)

AND 2" FROM

EDGE OF D.L.O.

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 20: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

135° Outside Corner - V8331

V8331-135-OSCFebruary 2017

FG-5262 MULLION

FG-5255 FILLER

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

FG-1133 GASKET

1 5/16" INSULATING

LAMINATED GLASS

FS-125

LOCATE @ 9"

O.C. BOTH SIDES

(STAGGERED)

AND 2" FROM

EDGE OF D.L.O.3"

3

"

5"

5

"

D.L.O.

D

.

L

.

O

.

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 21: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Vertical at Transom Sidelite - V8340

V8340-Vertical-at-Transom-SidelightFebruary 2017

FG-5217 FILLER

5"

GP-5185 SPACER GASKET

& STRUCTURAL SILICONE

FG-1133 GASKET

1 5/16" INSULATING

LAMINATED GLASS

2 1/2"

FG-5168 DOOR JAMB

FG-5000-PP-8 STEEL CHANNEL

FG-5181 SASH

FG-5182 TRANSOM

SASH STOP

FS-38

FG-5949

INTERIOR

GASKET

DRY GLAZED OPTION

Page 22: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL
Page 23: BuildingEnvelope - OBE...1-866-OLDCASTLE (653-2278) FG-5100T StormMax® Sill Horizontal - H8327 Febrary 2017 H8327-Sill-Horizontal FG-5214 HORIZONTAL FG-5185 SPACER GASKET W/ STRUCTURAL

1-866-OLDCASTLE (653-2278) www.obe.com

FG-5100T StormMax®

Meeting Stiles - V8345

V8345-Meeting-StilesFebruary 2017

D-24 DOOR

STILE

D-69 DOOR

STILE

D-134-3 PANIC

STOP

AS-6 ADJUSTABLE ASTRAGAL

13/16"3 3/4" 3 3/4"

13/16"D.L.O. D.L.O.

3"