Building planing 1
Click here to load reader
-
Upload
mintykshirsagar -
Category
Business
-
view
5.450 -
download
0
Transcript of Building planing 1
BUILDINGS & BUILDING PLANNING
GENERAL:- HOUSES, BUNGALOWS & FLATS FOR
LIVING. HOSPITALS & HEALTH CENTRES FOR
HEALTH. SCHOOL, COLLEGES & UNIVERSITIES
FOR EDUCATION. BANKS, SHOPS, OFFICES, BUILDINGS
FOR DOING WORK. RAILWAY BUILDINGS, BUS STATIONS &
AIR TERMINALS FOR TRANSPORTATION. CLUBS, THEATRES & CINEMA HOUSES
FOR RECREATION. TEMPLES, MOSQUES, CHURCHES FOR
WORSHIP.
CONSIDERATION IN BUILDING DESIGN:- CLIMATES & ITS EFFECT. PEOPLE & THEIR REQUIREMENT. MATERIALS FOR CONSTRUCTION. REGULATIONS & BYE- LAWS OF
SANCTIONING AUTHORITIES.
TYPES OF BUILDINGS:- GROUP A- RESIDENTIAL BUILDINGS. GROUP B- EDUCATIONAL BUILDINGS. GROUP C- INSTITUTIONAL BUILDINGS. GROUP D- ASSEMBLY BUILDINGS. GROUP E- BUSINESS BUILDINGS. GROUP F- MERCENTILE BUILDINGS. GROUP G- INDUSTRIAL BUILDINGS. GROUP H- STORAGE BUILDINGS. GROUP J- HAZARDOUS BUILDINGS.
RESIDENTIAL BUILDINGS:- BUILDING WITH SLEEPING
ACCOMMODATION WITH OR WITHOUT COOKING OR DINING FACILITIES.
SUB-DIVISION OF RESI. BUILDINGS A-1 :- LODGING & ROOMING HOUSES. A-2 :- ONE OR TWO FAMILY PRIVATE
DWELLING. A-3 :- DORMITORIES. A-4 :- APPARTMENT HOUSES. (FLATS) A-5 :- HOTELS.
A-1: LODGING OR ROOMING HOUSES. BUILDING WITH SEPARATE SLEEPING
ACCOMMODATION FOR NOT MORE THAN 15 PERSONS(TEMPORARY OR PERMANENT BASIS) WITH OR WITHOUT DINING FACILITIES BUT WITHOUT COOKING FACILITIES FOR INDIVIDUAL FACILITIES.
A-2: ONE OR TWO FAMILY PRIVATE DWELLING PRIVATE DWELLING WHICH IS OCCUPIED BY MEMBERS OF A
SINGLE FAMILY. SLEEPING ACCOMODATION FOR NOT MORE THAN 20 PERSONS. IF ROOMS ARE RENTED TO OUTSIDERS, THESE SHOULD BE FOR
ACCOMMODATING NOT MORE THAN 3 PERSONS.
A-3: DORMITORIES BUILDING IN WHICH GROUP SLEEPING ACCOMODATION IS
PROVIDED WITH OR WITHOUT DINING FACILITIES FOR PERSONS WHO ARE NOT MEMBERS OF SAME FAMILY, IN ANY ONE ROOM OR A SERIES OF CLOSELY ASSOCIATED ROOMS UNDER SINGLE MANAGEMENT. FOR EXAMPLE- SCHOOL & COLLEGE DORMITORIES, STUDENTS & OTHER HOSTELS.
A-4: APPARTMENT HOUSES
A-5: HOTELS
SITE SELECTION SITE SHOULD PREFERABLY BE SITUATED
ON AN ELEVATED AND LEVELLED GROUND.
IT SHOULD NOT BE LOCATED IN A FLOOD PRONE AREA.
THE SOIL AT SITE SHOULD HAVE GOOD VALUE OF BEARING CAPACITY.
THE SITE SHOULD NOT BE IRREGULAR IN SHAPE.THE SITE SHOULD BE RECTANGULAR OR SQUARE IN SHAPE.
THE SITE SHOULD BE LOCATED IN DEVELOPED AREA.
SITE SELECTION THE SITE SHOULD BE LOCATED AWAY
FROM QUARRIES, KILN, INDUSTRIAL PLANTS ETC.
THE SITE SHOULD HAVE UNOBSTRUCTED NATURAL LIGHT AND AIR.
BUILDING BYE-LAWS:-THE VARIOUS ASPECTS OF BUILDING
ACTIVITIES COVERED BY BYE-LAWS ARE UNDER:
DISTANCE FROM ELECTRIC LINES SET BACKS IN A PLOT. BUILT UP AREA LIMITATIONS. NORMS RELATED TO HEIGHT OR SIZES
OF ROOMS. LIGHTING & VENTILATION OF ROOMS. BUILDING SERVICES.
DISTANCE OF BUILDINGS FROM ELECTRIC LINE:
MINIMUM HEIGHTS OF DIFFERENT PARTS OF BUILDINGS:- HABITABLE ROOMS- 2.75 M. KITCHEN- 2.75 M. BATH ROOMS- 2.4 M. WC – 2.4 M. PLINTH LEVEL- 30 CM.
MINIMUM SIZES OF DIFF. PARTS OF BUILDINGS:- HABITABLE ROOMS- MIN WIDTH:- 2.4 M. MIN AREA :- 9.5 SQ.M DRAWING ROOM- MIN WIDTH:- 3 M. MIN AREA :- 11 SQ.M STUDY ROOM - MIN WIDTH:- 2.4 M. MIN AREA :- 9.5 SQ.M
MINIMUM SIZES OF DIFF. PARTS OF BUILDINGS:- KITCHEN WITH STORE- MIN WIDTH:- 1.5 M. MIN AREA :- 5.6 SQ.M KITCHEN HAVING SEPARATE STORE- MIN WIDTH:- MIN AREA :- 4.5 SQ.M KITCHEN WITH DINING ROOM- MIN WIDTH:- 2.4 M. MIN AREA :- 9.5 SQ.M
MINIMUM SIZES OF DIFF. PARTS OF BUILDINGS:- BATH ROOM - MIN WIDTH:- 1.5 M X 1.2M MIN AREA :- 1.8 SQ.M COMBINED BATHROOM & WC- MIN WIDTH:- 1.2M MIN AREA :- 1.8 SQ.M WC- MIN WIDTH:- MIN AREA :- 1.1 SQ.M
LIGHTING & VENTILATION OF ROOMS:- 1/10th OF FLOOR AREA IN DRY HOT
CLIMATE. 1/6TH OF FLOOR AREA IN WET HOT
CLIMATE. AREA OF DOORS & WINDOWS IN A
ROOM IS NOT LESS THAN 1/7TH OF FLOOR AREA.
BUILT UP AREA LIMITATION:-
BUILTUP AREA OR COVERED AREA OF A BUILDING ON GROUND- PLOT AREA- AREA OF OPEN SPACES AROUND THE
BUILDING.
F.A.R (FLOOR AREA RATIO):- F.A.R = COVERED AREA OF ALL FLOORS PLOT AREA
SETBACKS IN A PLOT BY JDA
SETBACKS IN A PLOT BY JDA
BUILDING SERVICES:- Water Supply Requirements for BuildingsWater Supply for Residences:-a) A minimum of 70 to 100 litres per head per
day for domestic needs of urban communities.
b) For communities with population upto 20000 and without flushing system:
1) water supply through = 40 lphd, Min standpost.
2) water supply through = 70 to 100 lphd house. service connection
WATER SUPPLY REQUIREMENTS FOR BUILDINGS
c) For communities with population 20000 to100000 together with full flushing system. = 100 to 150 lphd.
d) For communities with population above 100000 together with full flushing system.
= 150 to 200 lphd. Out of the 150 to 200 litres per head per day,45 litres per head per day may be taken for
flushingrequirements and the remaining quantity for
otherdomestic purposes.
THANKS- MADHUMITA KSHIRSAGAR.