    1. As per PD 1096 , under what classification shallgasoline filling and service stations be classified?

    A. assemblyB. business and mercantileC. IndustrialD. Accessory

    2. As per PD 1096 , what is the minimum clear width forGroup A dwelling stairs?

    A. 0.71mB. 0.75mC. 0.80mD. 0.90m

    3. Which is not a requirement in applying for BuildingPermit?

    A. Tax DeclarationB. Latest Income TaxC. plans and specificationsD. Current Real Property Tax Receipt

    4. What is referred to in works to buildings/structuresinvolving changes in the materials used, partitioning,and location/size of openings, structural parts, existingutilities and equipment but does not increase thebuilding height and/or floor area?

    A. AlterationB. ConversionC. RepairD. Renovation

    5. As per PD 1096 , under what classification shallfactories and workshops using less flammable or non-combustible materials is classified?

    A. IndustrialB. assemblyC. business and mercantileD. Accessory

    6. Which of the following is not covered in theframework of minimum standards and requirements for

    buildings under PD 1096 ?

    A. aesthetic valueB. maintenanceC. material qualityD. location

    7. As per PD 1096 , what is the size of automobileparking slot for perpendicular or diagonal parking?

    A. 2 x 5 mtrs.B. 2.5 x 5 mtrs.C. 2.15 x 6 mtrsD. 3 x 5 mtrs.

    8. As per PD 1096 , how many percent or parkingrequirements may be provided if adequate public

    parking lots/multi-floor parking garages are availablewithin 200 meters of the proposed buildings/structures?

    A. 10 %B. 15 %C. 20 %D. 25 %

    9. As per PD 1096 , what is the minimum front setbackfor a Residential R-1 lot?

    A. 3.00 mtrsB. 3.50 mtrs.C. 4.50 mtrs.D. 5.00 mtrs.

    10. As per PD 1096 , what is the classification of buildingsof masonry and wood construction with a one-hour fire-resistivity throughout and exterior walls ofincombustible fire-resistive construction?

    A. Type IB. Type IIC. Type IIID. Type IV

    11. As per PD 1096 , what is the minimum air space perperson for a habitable room with natural ventilation?

    A. 10 cumB. 12 cumC. 14 cumD. 16 cum

    12. For residential occupancies, how many percent of aninterior lot is open space?

    A. 25%B. 30%C. 40%D. 50%

    13. As per PD 1096 , what is the minimum width foraccess road to interior lots?

    A. 3mB. 4m

    C. 5mD. 6m

    14. Which is not considered a basis of assessment forbuilding permit fees?

    A. cost of constructionB. floor areaC. lot areaD. building use

    15. As per PD 1096 , what is the minimum clear ceilingheight for mezzanine floors above and below it?

    A. 1.70mB. 1.80mC. 1.90mD. 2.00m

  • 8/12/2019 Building Laws Key Answer

    2/10

    16. As per PD 1096 , what is the minimum widthdimension of a court?

    A. 1.20mB. 1.80 mC. 2.00 mD. 2.10 m

    17. As per PD 1096 , what is the minimum clearancebetween the established grade of a street and/orsidewalk and the lowest under-surface of any part of aprojecting balcony?

    A. 2.00mB. 2.40mC. 2.80mD. 3.00m

    18. As per PD 1096 , what is the maximum distance ofaccessible parking area for the physically handicappedfrom facility being served?

    A. 40 mtrs.B. 50 mtrs.C. 60 mtrs.D. 70 mtrs.

    19. Failure to commence the work within a period of ______months from the date of issuance of permit is abasis for non-issuance, suspension or revocation of aBuilding Permit.

    A. 3B. 6C. 8D. 12

    20. Which is not a ground for the non-issuance,suspension or revocation of a Building Permit?

    A. non-compliance to CodeB. inaccurate applicationC. non-submittal of logbookD. unauthorized change in plan

    21. As per PD 1096 , what is the ratio of parking slot togross floor area of office buildings?

    A. 1 slot/100 sqm.B. 1 slot/125 sqm.C. 1 slot/ 150 sqmD. 1 slot/200 sqm.

    22. As per PD 1096 , what is the ratio of parking slot tonumber of units in residential hotels and apartels?

    A. 1 slot / 5 unitsB. 1 slot / 10 unitsC. 1 slot / 15 unitsD. 1 slot / 12 units

    23. As per PD 1096 , what is referred to by the totalnumber of persons that may occupy a building or aportion thereof at any one time?

    A. building occupancyB. occupant loadC. building usageD. unit capacity

    24. As per PD 1096 , what is the minimum ceiling heightof the first storey of a habitable room provided withartificial ventilation?

    A. 2.00mB. 2.10 mC. 2.40 mD. 2.70 m

    25. As per PD 1096 , a wheelchair transfer area isrequired for every how many parking spaces inbuildings/structures intended for the use or occupancyof the handicapped?

    A. 2 spacesB. 3 spacesC. 4 spacesD. 5 spaces

    26. An extremely hot luminous bidge formed by passage

    of an electric current across a space between twoconductors or terminals due to the incandescence of theconducting vapor.

    A. PyrophoricB. Flash PointC. Electric ArcD. Fulminate

    27. In integrated system of underground or overheadpiping or both connected to a source of extinguishingagent or medium which when actuated by its automaticdetecting device suppresses fire.

    A. Fire protective assemblyB. Fire alerting systemC. Automatic fire suppression systemD. Fire sprinkler system

    28. As per PD 1185 , what is the maximum number ofseats in rows of seats between aisles for places ofassembly?

    A. 5B. 7C. 12D. 14

    29. Passageway from one building to another or around

    a wall in approximately the same floor level.

    A. Fire LaneB. Horizontal ExitC. Public WayD. Vestibule

    30. As per PD 1185 , what is the maximum traveldistance for places of assembly if not protected byautomatic fire suppression system?

    A. 46 mts.B. 56 mts.C. 61 mts.D. 71 mts

  • 8/12/2019 Building Laws Key Answer

    3/10

    31. A bar which extends across at least one-half of eachdoor leaf, which will open the door if subjected topressure.

    A. Flush boltB. Door jambC. Door handleD. Panic hardware

    32. As per PD 1185 , what is the minimum width for anysingle door in a doorway?

    A. 61 cm.B. 71 cm.C. 81 cm.D. 91cm

    33. Descriptive of any material which by its nature or asa result of its reaction with other elements produces arapid drop in temperature of the immediatesurroundings

    A. Oxidizing MaterialB. CryogenicC. Combustible LiquidD. Pyrophoric

    34. As per PD 1185 , what is the minimum number ofexits for Class A places of assembly with a capacity ofmore than 1,000 persons?

    A. 2B. 3C. 4D. 6

    35. As per PD 1185 , under what classification does fire inflammable liquids and gasses belong to?

    A. Class AB. Class BC. Class CD. Class D

    36. As per PD 1185 , dwelling units in row apartmentsshall be separated from each other by partition wallshaving a fire resistance rating of how many hours?

    A. 1 hour

    B. 2 hourC. 3 hourD. 4 hour

    37. As per PD 1185 , buildings over this height shall berequired throughout with automatic fire sprinklersystem.

    A. 10mB. 12mC. 15mD. 18m

    38. As per PD 1185 , which is not a factor for determiningdegree of hazard?

    A. type of occupancyB. construction materials usedC. combustibility of contentsD. floor area

    39. As per PD 1185 , between any point in aninstitutional sleeping room or suite and an exit accessdoor of that room or suite shall not exceed how manymeters?

    A. 15 mtrs.B. 23 mtrs.C. 30 mtrs.D. 46 mtrs.

    40. As per PD 1185 , what is the minimum opening widthof doors?

    A. 0.71mB. 0.81m

    C. 0.90mD. 0.91m

    41. Degree of hazard is determined by: i. Fire resistancerating ii.Probability that a building, structure or facilitymay catch fire iii.Difficulty in evacuating people iv.Difficulty in suppressing fire

    A. i, ii, iiiB. ii, iii, ivC. i, iii, ivD. i, ii, iv

    42. A building unsafe in case of fire because it will burneasily or because it lacks adequate exits or fire escapes.

    A. Fire AbatementB. Fire LaneC. Fire HazardD. Fire TrapExplanation

    43. As per PD 1185 , what is the unit of exit width usedto measure means of egress?

    A. 50 cm.B. 55 cm.

    C. 60 cm.D. 65 cm.

    44. As per PD1185 , what is the minimum headroomclearance for Class B stairs?

    A. 1.95mB. 2.00mC. 2.05m (D. 2.10m

    45. A rocket or liquid propellant which consist ofcombinations of fuels and oxidizers which ignitespontaneously on contact with each other.

    A. Hypergolic Fuel

  • 8/12/2019 Building Laws Key Answer

    4/10

    B. CryogenicC. Corrosive LiquidD. Combustible Liquid

    46. Separated from other spaces of the building orstructure by construction or equipment to provide aprotected way of travel to the exit discharge.

    A. Fire LaneB. Horizontal ExitC. Fire ExitD. VestibuleExplanation

    47. As per PD 1185 , every room or space in educationaloccupancies with a capacity of over 50 persons shallhave at least how many doorways?

    A. 1 doorwayB. 2 doorways

    C. 3 doorwaysD. 4 doorways

    48. As per PD 1185 , what is the maximum force that isapplied to the releasing device of the panic hardware inthe direction of exit travel that shall cause the door latchto release?

    A. 5 kilosB. 6 kilosC. 7 kilosD. 8 kilos

    49. As per PD 1185 , what is the minimum aisle width forless than 60 seats in places of assembly?

    A. 0.76 mtr.B. 0.83 mtr.C. 0.91 mtr.D. 1.00 mtr

    50. As per PD 1185 , what is the minimum width of runexclusive of nosing or projection for Class B stairs?

    A. 0.23mB. 0.24mC. 0.25m

    D. 0.30m

    51. As per BP 220 , what is the maximum length of analley in a residential block?

    A. 20 mtrs.B. 40 mtrs.C. 60 mtrsD. 80 mtrs.

    52. As per BP 220 , what is the minimum clear width ofstairways?

    A. 0.60 mtrs.B. 0.70 mtrs.C. 0.71 mtrs.

    D. 0,75 mtrs.

    53. As per BP 220 , maintain a ratio for house and lotwhere ___% of the selling price for a house and lotpackage is allotted for the house and ____% for the lot.

    A. 60 % / 40%B. 70% / 30%C. 75% / 25%D. 80% / 20%

    54. What basic principle is applied in the basic planningrequirements of BP 344 standards so that finding aperson's way inside and outside of a building or openspace shall be made easy for everyone?

    A. AccessibilityB. UsabilityC. ReachabilityD. Orientation

    55. As per BP 344 , entrances with vestibules shall beprovided with at least how much depth to allow adisabled person to open the door and allow hiswheelchair to pass through easily?

    A. 1.8 mtrs.B. 2.4 mtrsC. 3.0 mtrs.D. 3.5 mtrs

    56. As per PD 957 , what is the minimum floor area offamily condominium units for open market?

    A. 18B. 22C. 32D. 36

    57. As per BP 220 , which is not a site criteria fordetermining whether an economic and socializedhousing shall be allowed?

    A. climate conditionB. AccessibilityC. conformity to zoningD. availability of basic needs

    58. As per PD 957 , what is the minimum area for a singlepark/playground in a residential condominium project?

    A. 50 sqm.B. 100 sqm.C. 150 sqmD. 200 sqm.

    59. As per PD 957 , what is the minimum width for roadsor right -of-way for residential condominium projects?

    A. 6 mtrs.B. 8 mtrs.C. 10 mtrs.D. 12 mtrs

  • 8/12/2019 Building Laws Key Answer

    5/10

    60. As per BP 220 , which among the following is thehighest in the heirarchy of basic needs of humansettlements, the provision of which shall be based onthe actual setting which the project is located?

    A. park/playgroundB. powerC. waterD. movement and circulation

    61. As per BP 220 , what is the minimum dimension forstairway tread and riser respectively?

    A. 200 / 250 mmB. 250 / 200 mmC. 250 / 300 mmD. 300 / 250 mm

    62. What is the minimum floor area for open markethousing units as per PD 957 ?

    A. 22 sqmB. 30 sqmC. 42 sqmD. 54 sqm

    63. As per BP 344 , a level area of not less than howmany meters shall be provided at the top and bottom ofany ramp?

    A. 1.4 mtrs.B. 1.5 mtrs.C. 1.8 mtrs.D. 1.9 mtrs

    64.What is the minimum floor area for economichousing units as provided for in BP 220 ?

    A. 16 sqmB. 18 sqm.C. 20 sqmD. 22 sqm

    65.What is the minimum lot frontage for rowhouse unitsin economic housing as provided for in BP 220 ?

    A. 3 mtrs.

    B. 3.5 mtrsC. 4 mtrs.D. 4.5 mtrs

    66. As per BP 220 , what is the minimum area for parksand playgrounds?

    A. 50 sqm.B. 100 sqmC. 150 sqmD. 200 sqm.

    67. As per BP 344 , how much is the parking slot widthfor handicapped drivers and passengers providingsufficient clear space between parked cars to allowthem to transfer to a wheelchair?

    A. 3.6 mtrs.B. 3.7 mtrsC. 3.8 mtrs.D. 3.9 mtrs

    68. As per BP 220 , which of the following is not animportant planning consideration for circulation systemlayout?

    A. observe hierarchy of roadsB. consider topographyC. consider access and safetyD. consider climate

    69. As per BP 344 , how many seats shall be designatedfor disabled persons in passenger trains?

    A. 2B. 4

    C. 6D. 8

    70. Which of the following is not included in the outlineprescribed by the Department of Environment andNatural Resources for the preparation of anEnvironmental Impact Statement?

    A. Project SettingB. Mitigation MeasuresC. Contingency PlansD. Project Cost

    71. A dwelling on one lot containing separate living unitsfor 3 or more families, usually provided with commonaccess, services, and use of land?

    A. cluster housingB. multi-family dwellingC. rowhouseD. planned unit development

    72. An interest in real property consisting of a separateinterest in a unit in a residential, industrial, orcommercial building and an undivided interest incommon, directly or indirectly, in the land on which it islocated and in other common areas of the building

    A. ApartelleB. TownhouseC. ApartmentD. Condominium

    73. As per BP 220 , how many percent of the grosssubdivision area shall be allocated for parks andplaygrounds if the density is 250 dwelling units perhectare in socialized housing?

    A. 9%B. 10%C. 12%D. 15%

  • 8/12/2019 Building Laws Key Answer

    6/10

    74. As per BP 344 , centerline heights of the topmostcontrol buttons or switches shall be how much from thefloor so as they are within reach of a person seated on awheelchair?

    A. 0.80 to 1.00 mtr.B. 0.80 to 1.20 mtrsC. 0.90 to 1.00 mtr.D. 0.90 to 1.20 mtrs.

    75. As per BP 344 , what is the required minimumwalkway width to permit a person in wheelchair totraverse it with safety?

    A. 1.10 mtrs.B. 1.20 mtrs.C. 1.25 mtrsD. 1.5 mtrs

    76. As per BP 220 , what is the minimum distance

    between buildings with more than 4 storeys?

    A. 6 mrs.B. 8 mtrs.C. 10 mtrsD. 12 mtrs

    77.What is the minimum lot frontage of a regular lot forsingle-detached units as provided for in BP 220 ?

    A. 4 mtrs.B. 6 mtrs.C. 8 mtrs.D. 10 mtrs

    78. As per PD 957 , what is the minimum lot frontage ofan interior lot for single-detached units?

    A. 3 mtrs.B. 4 mtrs.C. 5 mtrs.D. 6 mtrs

    79. As per BP 220 , what is the minimum distancebetween two buildings wherein the taller building has 3or 4 storeys?

    A. 4 mtrs.B. 5 mtrs.C. 6 mtrs.D. 7 mtrs.

    80. As per BP 220 , what is the maximum length forrowhouse units?

    A. 50 mtrs.B. 100 mtrs.C. 150 mtrs.D. 250 mtrs.

    81. As per BP 344 , accessible public washrooms andtoilets shall permit easy passage of a wheelchair andmust allow how much turning space for wheelchairs?

    A. 1.50 sqm.B. 1.70 sqm.C. 2.0 sqm.D. 2.25 sqm.

    82. What is the minimum lot area for open marketrowhouse units as prescribed in PD 957 ?

    A. 50 sqm.B. 60 sqm.C. 70 sqm.D. 80 sqm

    83. As per BP 220 , how many percent of the grosssubdivision area shall be allocated for communityfacilities if the density is not more than 150 dwellingunits per hectare in socialized housing?

    A. 1%

    B. 1.5%C. 2%D. 2.5%

    84. As per BP 344 , what is the maximum distancebetween reststops of turn-around spaces in walkways?

    A. 5 mtrs.B. 6 mtrsC. 10 mtrs.D. 12 mtrs.

    85.What is the minimum lot area for single-detachedsocialized housing units as provided for in BP 220 ?

    A. 54 sqmB. 62 sqm.C. 64 sqm.D. 72 sqm

    86. As per BP 344 , what is the maximum length of aramp if the ramp gradient is 1:12?

    A. 4 mtrs.B. 6 mtrs.C. 8 mtrsD. 10 mtrs

    87. As per BP 344 , how long is the extension of handrailswhich shall be provided from the start and end of rampsand stairs?

    A. 150 mm.B. 200 mm.C. 250 mmD. 300 mm.)

    88. As per PD 957 , what is the maximum block lengthwithout an alley?

    A. 250 mtrs.B. 300 mtrs.C. 350 mtrs.

  • 8/12/2019 Building Laws Key Answer

    7/10

    D. 400 mtrs

    89. As per PD 957 , parks/playground or otherrecreational facilities may not be required if thecondominium is located not more than or _____ metersfrom a publicly accessible park/playground/or otherrecreational facilities.

    A. 200B. 400C. 800D. 1000

    90. As per PD 957 , what is the prescribed ratio forsaleable and non-saleable lots?

    A. 60% / 40%B. 70% / 30%C. 75% / 25%D. 80% / 20%

    91. Toilet and bath rooms, laundry rooms and similarrooms shall be provided with window or windows withan area of not less than _____ of the floor area of suchrooms, and such openings shall not be less than 240 sq.mm.

    A. 1/5B. 1/10C. 1/15D. 1/20

    92. Minimum width of access road for interior or rearlots

    A. 3.00mB. 4.00mC. 5.00mD. 6.00m

    93. An unoccupied space other than a yard bounded onthree sides by building lines with one side bounded byanother open space whether public or private.

    A. Inner courtB. Open courtC. Through court

    D. Private court

    94. The maximum height and number of stories of everybuilding shall be dependent upon the following:I. Character of occupancy iii. Environmentalconditions..ii. Type of construction IV. Capacity ofpublic utility/service systems

    A. i, ii, iiiB. i, iii, ivC. i, ii, ivD. i, ii, iii, iv

    95. Bath and toilets shall have a minimum area of ______ with a least dimension of ______.

    A. 1.2 sqm.; 0.90 mts.B. 1.5 sqm.; 0.75 mts.C. 1.5 sqm.; 0.90 mts.)D. 1.2 sqm.; 0.75 mts.

    96. Minimum ceiling height measured from the floor tothe ceiling of habitable rooms provided with artificialventilation

    A. 1.8 mts.B. 2.0 mts.C. 2.4 mtsD. 2.7mts.

    97. Minimum air space for school rooms shall be _____cubic meters with ____ square meter of floor areaper person

    A. 3.0 ; 1.0B. 4.0 ; 1.2

    C. 3.0 ; 1.2D. 4.0 ; 1.0

    98. Which of the following statements are NOT true? --i.No building shall be constructed unless it adjoins or hasdirect access to a public space, yard or street on at leastone of its sides--;-- ii. Where length of run for access tointerior lots is 200 mts, a cul-de-sac or turn court shallbe provided for each maximum run of 50 mts.--;-- iii.Parking space shall be provided inclusive of access roadrequirement when number of independent living unitswith individual entrances is increased as in multi-storyapartments.--;-- iv. Only some specific buildings shallface a public street, alley or a private road.

    A. i and ii (B. ii and iiiC. iii and ivD. None of the above

    99. Rooms for human habitations shall have a minimumarea of ______ with a least dimension of ______.

    A. 4 sqm.; 2 mts.B. 6 sqm.; 2 mts.C. 6 sqm.; 3 mts.D. 9 sqm.; 3 mts

    100. When the horizontal distance between theoutermost portion face of the building and the inneredge of the sidewalk is more than one-half the height ofthe building, only a fence is required as protectionduring construction. Height of fence is ___.

    A. 1.8 mts.B. 2.0 mts.C. 2.4 mts.D. 3.00 mts

    101. The minimum horizontal dimension for courts andyards.

    A. 1.2 mts.

  • 8/12/2019 Building Laws Key Answer

    8/10

    B. 2.0 mtsC. 2.4 mtsD. 3.0 mts.

    102. Minimum air space per person for habitable rooms

    A. 9 cubic mts.B. 12 cubic mts.C. 14 cubic mtsD. 16 cubic mts

    103. An unoccupied space other than a yard bounded ontwo opposite sides by building lines with the otheropposite side bounded by other open spaces whetherpublic or private.

    A. Inner courtB. Open courtC. Through courtD. Private court

    104. The lowest point of elevation of the finishedsurface of the ground between the exterior wall of abuilding and a point 1.50 meters distant from the saidwall.

    A. Adjacent ground elevationB. Established ground elevationC. DatumD. Reference level

    105. The classification of use or occupancy ofbuildings/structures or portions thereof.

    A. Character of occupancyB. Type of constructionC. ZoningD. Land use

    106. Minimum ceiling height measured from the floor tothe ceiling of habitable rooms with natural ventilation

    A. 2.0 mts.B. 2.4 mts.C. 2.7 mts.D. 3.0 mts

    107. Minimum access road width for interior or rear lotson which more than 35 units of apartments, row housesor accessories or group of single detached units are built

    A. 4.00mB. 5.00mC. 6.00mD. 7.50m

    108. Not an example of a private open space

    A. AlleysB. YardsC. SetbacksD. Light wells

    109. Rooms intended for any use without any artificialventilation shall have windows with a total free area ofopenings equal to at least ____ percent of the floor areaof the room but such opening shall not be less than 1.0sqm.

    A. 5B. 10C. 15D. 20

    110. The point of reference on the highest adjoiningsidewalk or the highest adjoining ground surface.

    A. Adjacent ground elevationB. Established ground elevationC. DatumD. Reference level

    111. Kitchens shall have a minimum area of ______ with

    a least dimension of ______.

    A. 3 sqm.; 1 mtr.B. 4.5 sqm.; 1.5 mtsC. 6 sqm.; 3 mts.D. 3 sqm.; 1.5 mts.

    112. Minimum air space per person for workshop,factories, and offices

    A. 9 cubic mtsB. 12 cubic mts.C. 14 cubic mts.D. 16 cubic mts

    113. An unoccupied space other than a yard bounded onall sides or around its periphery by building lines

    A. Inner courtB. Open courtC. Through courtD. Private court

    114. The vertical distance from the established gradeelevation to the highest point of the opening of a flatroof, to the average height of the coping of a flat roof, tothe average height of the highest gable, pitch or hip roof

    or to the top of the parapet, if the roof is provided witha parapet, whichever is higher.

    A. Adjacent ground elevationB. Established grade elevationC. Height of buildings/structureD. Building bulk

    115. The classification based on the fire resistivityratings of materials and methods of construction ofbuildings/structures or portions thereof.

    A. Character of occupancyB. Type of constructionC. Fire zoneD. Fire hazard

  • 8/12/2019 Building Laws Key Answer

    9/10

    116. The floor area assigned to that use divided by theunit area per occupant.

    A. densityB. Occupant loadC. Building bulkD. Floor area ratio

    117. Multi-family living units regardless of number ofstories with an average living unit floor area of up to 50sqm shall have 1 parking slot per how many living units.

    A. 1B. 4C. 8D. 10

    118. Multi-family living units regardless of number ofstories with an average living unit floor area of up to 50sqm shall have 1 parking slot per how many living units.

    A. 1B. 4C. 8D. 10

    119. Low-income single-detached living units in housingproject areas with individual lots not more than 100square meters shall have a pooled parking at 1 slot perhow many living units.

    A. 5B. 10C. 15D. 20

    120. For clubhouses, beach houses, and the like,minimum required parking is 1 slot per how many sqmof gross floor area.

    A. 50B. 75C. 100D. 125

    121. For residential hotels and apartels, minimumrequired parking is 1 slot per how many units.

    A. 2B. 5C. 8D. 10

    122. That part of any wall entirely above the roof line

    A. Fire wallB. Curtain wallC. Parapet wallD. Retaining wall

    123. Multi-family living units regardless of number ofstories with an average living unit floor area of more

    than 100 sqm shall have 1 parking slot per how manyliving units.

    A. 1B. 4C. 8D. 10

    124. Parking areas for the physically handicapped shallbe within how many meters of the facility being servedmeasured from the farthest parking space alongaccessible path to the closest accessible distance.

    A. 30B. 40C. 60D. 80

    125. Any wall used to resist the lateral displacement ofany material; a subsurface wall built to resist the lateral

    pressure of internal loads.

    A. party wallB. Curtain wallC. Foundation wallD. Retaining wall

    126. For hotels, minimum required parking is 1 slot perhow many rooms.

    A. 2B. 4C. 8D. 10

    127. For public assembly buildings such as theaters,cinemas, auditoria, stadia, etc., minimum requiredparking is 1 slot per how many sqm of spectator area.

    A. 50B. 100C. 150D. 200

    128. For places of worship and funeral parlors, minimumrequired parking is 1 slot per how many sqm ofcongregation area.

    A. 50B. 100C. 150D. 200

    129. For elementary, secondary, vocational and tradeschools, minimum required parking is 1 slot per howmany classrooms.

    A. 5B. 10C. 15D. 20

  • 8/12/2019 Building Laws Key Answer

    10/10

    130. The enclosing wall of an iron or steel or thenonbearing portion of an enclosed wall between piers.

    A. Curtain wallB. Fire wallC. Exterior wallD. Faced wall

    131. For colleges and universities, minimum requiredparking is 1 slot per how many classrooms.

    A. 5B. 10C. 15D. 20

    132. Any wall which subdivides a building so as to resistthe spread of fire, by starting at the foundation andextending continuously through the storey to, or abovethe roof.

    A. party wallB. Foundation wallC. FirewallD. Nonbearing wall

    133. For hospitals, minimum required parking is 1 slotper how many beds.

    A. 15B. 20C. 25D. 30

    134. For motels, minimum required parking is 1 slot perhow many units.

    A. 1B. 2C. 3D. 4

    135. For office buildings, minimum required parking is 1slot per how many sqm of gross floor area.

    A. 50B. 100

    C. 125D. 150

    136. For neighborhood shopping center, minimumrequired parking is 1 slot per how many sqm of shoppingfloor area.

    A. 25B. 50C. 75D. 100

    137. One wheelchair transfer area is to be provided inevery ___ parking spaces directly connected toaccessible walks of travel and accessible buildingentrances.

    A. 2B. 4C. 6D. 8

    138. For buildings/structures intended for the use oroccupancy of the handicapped, a minimum provision ofone parking slot for the handicapped per 50 parking lotsup to _____ parking slots and an additional slot forevery 100 slots thereafter.

    A. 100B. 150C. 200D. 250

    139. For markets, minimum required parking is 1 slotper how many sqm of market floor area.

    A. 50B. 100C. 150D. 200

    140. Multi-family living units regardless of number ofstories with an average living unit floor area above 50sqm to 100 sqm shall have 1 parking slot per how manyliving units.

    A. 1B. 4C. 8D. 10

    141. In all occupancies, floors above the first storyhaving an occupant load of more than ten (10) shall nothave less than ____ exits.