Macurco TM Building & Home Solutions Building & Home Solutions BEVERAGE DISPENSING CODE Carbon Dioxide (CO 2 ) Code International Fire Code 2015 - Section 5307 Carbon Dioxide (CO 2 ) • The 2015 edition of the International Fire Code (IFC) now requires mechanical ventilation or an emergency alarm system when the quantity of CO 2 exceeds 100 pounds. • 5307.5.2 Emergency Alarm System • An emergency alarm system shall comply with all of the following: 1. Continuous gas detection shall be provided to monitor areas where carbon dioxide can accumulate. 2. The threshold for activation of an alarm shall not exceed 5,000 parts per million 3. Activation of the emergency alarm system shall initiate a local alarm within the room or area in which the system is installed. • The new requirements in the 2015 IFC came about after several fatal carbon dioxide poisonings occurred in the United States in restaurants where CO 2 leaked from large storage containers and displaced oxygen in the area. CO 2 is an odorless and colorless gas heavier than air and will fill a room from bottom to top displacing the oxygen, creating a potential life safety hazard to building occupants and emergency responders. • Although the 2015 IFC contains new language regarding CO 2 systems please check with your local government units of the status of this code in your area. • For more information on the code please refer to the following link: IFC 2015 Code Key Features Applications Accessories • 0-5000 PPM Range • Dual Alarm Relay (Low & High Levels) • Digital Display / Onboard Buzzer • Low Voltage (CD-6H / CD-6MC) 12-24AC/DC or Line Voltage (CD-12H / CD-12MC) 120VAC • Can Be Used Standalone or Connected to Burglar/Fire Panel, or Macurco Controller • Convenience Stores • Fast Food Restaurants • Restaurants / Bars • Grocery Stores • Breweries / Distilleries / Wineries • Arenas / Stadiums • Theaters • Horn and Strobe (24VDC only) • PS-24 (Plug in 24VDC Power) • DVP-120 Control Panel • CO 2 Test Gas CD-6H / CD-6MC Carbon Dioxide (CO 2 ) Detector, Controller & Transducer © Aerionics 2019. All rights reserved. Macurco is a trademark of Aerionics, Inc. Website: www.macurco.com Phone: 1-877-367-7891 Macurco Gas Detection Email: [email protected] Technical Support Phone: 1-844-325-3050 Website: https://macurco.com/service/ Email: [email protected] 04/19 Made in the USA

Transcript of Building & Home Solutions - Macurco Gas Detection · leaked from large storage containers and...

Page 1: Building & Home Solutions - Macurco Gas Detection · leaked from large storage containers and displaced oxygen in the area. CO 2 is an odorless and colorless gas heavier than air

MacurcoTM

Building & Home Solutions Building & Home Solutions

BEVERAGE DISPENSING CODE

Carbon Dioxide (CO2) CodeInternational Fire Code 2015 - Section 5307 Carbon Dioxide (CO2)

• The 2015 edition of the International Fire Code (IFC) now requires mechanical ventilation or an emergency alarm system when the quantity of CO2 exceeds 100 pounds. • 5307.5.2 Emergency Alarm System• An emergency alarm system shall comply with all of the following: 1. Continuous gas detection shall be provided to monitor areas where carbon dioxide can accumulate. 2. The threshold for activation of an alarm shall not exceed 5,000 parts per million 3. Activation of the emergency alarm system shall initiate a local alarm within the room or area in which the system is installed.

• The new requirements in the 2015 IFC came about after several fatal carbon dioxide poisonings occurred in the United States in restaurants where CO2 leaked from large storage containers and displaced oxygen in the area. CO2 is an odorless and colorless gas heavier than air and will fill a room from bottom to top displacing the oxygen, creating a potential life safety hazard to building occupants and emergency responders.• Although the 2015 IFC contains new language regarding CO2 systems please check with your local government units of the status of this code in your area.• For more information on the code please refer to the following link: IFC 2015 Code

Key Features Applications Accessories• 0-5000 PPM Range• Dual Alarm Relay (Low & High Levels)• Digital Display / Onboard Buzzer• Low Voltage (CD-6H / CD-6MC) 12-24AC/DC or Line Voltage (CD-12H / CD-12MC) 120VAC • Can Be Used Standalone or Connected to Burglar/Fire Panel, or Macurco Controller

• Convenience Stores• Fast Food Restaurants• Restaurants / Bars• Grocery Stores• Breweries / Distilleries / Wineries• Arenas / Stadiums• Theaters

• Horn and Strobe (24VDC only)• PS-24 (Plug in 24VDC Power)• DVP-120 Control Panel• CO2 Test Gas

CD-6H / CD-6MC Carbon Dioxide (CO2) Detector, Controller & Transducer

© Aerionics 2019. All rights reserved. Macurco is a trademark of Aerionics, Inc.